ML20117L356

From kanterella
Jump to navigation Jump to search
Forwards Rept 51-1245664-00, STP Unit 1 May 1996 1RE06-90-Day Rept for Voltage-Based Repair Criterion for ODSCC at Tube Support Plates, Per GL 95-05
ML20117L356
Person / Time
Site: South Texas STP Nuclear Operating Company icon.png
Issue date: 09/05/1996
From: Thomas S
HOUSTON LIGHTING & POWER CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML20117L357 List:
References
GL-95-05, GL-95-5, ST-HL-AE-005466, ST-HL-AE-5466, STI-30100015, NUDOCS 9609130125
Download: ML20117L356 (3)


Text

'

l 9

The Light c o m p a n yS uth Texas Project Dectric Generating Station P. O. Box 289 Wasworth, Texas 77483 liouston Lighting & Power September 5, 1996 l

ST-HL-AE-005466 STI-30100015 l

File No.: G20.01 l

10 CFR 50 U.S. Nuclear Regulatory Commission Attention: Document Control Desk Washington, DC 20555 South Texas Project Electric Generating Station Unit 1 Docket No. STN 50-498 Unit 1 Sixth Refueling Outage Steam Generator Tube Voltane Based Repair Criteria 90 Day Report The Unit I sixth refueling outage (IRE 06) Steam Generator Tube Voltage Based Repair Criteria 90 Day Report for examination performed under NRC Generic Letter 95-05 at the South Texas Project Electric Generating Station is enclosed. This report contains the information required in Section 6.b, Information To Be Provided Following Each Restart, of Generic Letter 95-05.

If you should have any questions on this matter, please contact Mr. IL R. Pate at (512) 972-7787 or me at (512) 972-7162.

I

~

S. E. Thomas

Manager, Design Engineering Department j

HRP/lf

^f

,dbbf

/

i 10^n 0

-vue Attachments: 1RE06 Steam Generator Tube Voltage Based Repair Criteria 90 Day Report 9609130125 960905 PDR ADOCK 05000498 P

PDR Project Manager on Behalf of the Participants in the South Texas Project MISC-963466.W

i Houston Lighting & Power Company ST-HL-AE-5466 l

South Texas Project Electric Generating Station STI-30100015 i

File No.: G20.01 Page 2 Leonard J. Callan Rufus S. Scott Regional Administrator, Region IV Associate General Counsel U. S. Nuclear Regulatory Commission Houston Lighting & Power Company 611 Ryan Plaza Drive, Suite 400 P. O. Box 61067 Arlington, TX 76011-8064 Houston, TX 77208 Thomas W. Alexion Institute of Nuclear Power i

Project Manager, Mail Code 13H3 Operations - Records Center U. S. Nuclear Regulatory Commission 700 Galleria Parkway Washington, DC 20555-0001 Atlanta, GA 30339-5957 David P. Loveless Dr. Bertran Wolfe Sr. Resident Inspector 15453 Via Vaquero c/o U. S. Nuclear Regulatory Comm.

Monte Sereno, CA 95030 l

P. O. Box 910 l

Bay City, TX 77404-0910 Richard A. Ratliff Bureau of Radiation Control l

J. R. Newman, Esquire Texas Department of Health l

Morgan, Lewis & Bockius 1100 West 49th Street 1800 M Street, N.W.

Austin, TX 78756-3189 Washington, DC 20036-5869 U. S. Nuclear Regulatory Comm.

l M. T. Hardt/W. C. Gunst Atta: Document Control Desk City Public Service Washington, DC 20555-0001 P. O. Box 1771 San Antonio, TX 78296 J. C. Lanier/M. B. Lee J. R. Egan, Esquire City of Austin Egan & Associates, P.C.

Electric Utility Department 2300 N Street, N.W.

721 Barton Springs Road Washington, D.C. 20037 l

Austin, TX 78704 Central Power and Light Company J. W. Beck ATfN: G. E. Vaughn/C. A. Johnson Little Harbor Consultants, Inc.

P. O. Box 289, Mail Code: N5012 44 Nichols Road Wadsworth, TX 77483 Cohassett, MA 02025-1166

=-

l l

1RE06 STEAM GENERATOR TUBE VOLTAGE BASED REPAIR CRITERIA 90 DAY REPORT l

l l

SOUTII TEXAS PROJECT ELECTRIC GENERATING STATION l

l UNIT NO.1 I

USNRC DOCKET NO.: 50-498 l

OPERATING LICENSE NO.: NPF-76 COMMERCIAL OPERATION DATE: AUGUST 25,1988 l

Prepared by:

FRAMATOME TECHNOLOGIES Reviewed by :

I 7

7[o Ronald L. Baker Date Senior Consulting Engineer-Design Engineering Department Approved by:M 9 66d S. E. Thomas Date Manager - Design Engineering Department I

l