Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20127D187 + (22:12:04, 12 December 2024)
- ML20127D189 + (22:12:04, 12 December 2024)
- ML20127D185 + (22:12:05, 12 December 2024)
- ML20127D184 + (22:12:13, 12 December 2024)
- 05000296/LER-1985-015-02, :on 850515,during Performance of Surveillance Instruction 4.1.A.14,all Four Turbine First Stage Pressure Permissive Switches Found Out of Calibr.Cause Attributed to Instrument Drift.Switches Recalibr & Tested + (22:12:15, 12 December 2024)
- ML20127D181 + (22:12:16, 12 December 2024)
- ML20127D180 + (22:12:17, 12 December 2024)
- ML20127D176 + (22:12:18, 12 December 2024)
- IR 05000224/1985001 + (22:12:20, 12 December 2024)
- ML20127D175 + (22:12:20, 12 December 2024)
- 0CAN099202, Submits Update of Status of Historical Commitments Re Util Correspondence Covering Corrected Info for NUREG-0737,Item II.D.1 Analysis,Submittal of C-E QA Plan Prior to Future Onsite Contracts & Recording of HPI Line Temps + (22:12:21, 12 December 2024)
- ML20127D170 + (22:12:22, 12 December 2024)
- ML20127D169 + (22:12:23, 12 December 2024)
- 05000412/LER-1992-010, :on 920809,containment Air Recirculation Fans Tripped,Resulting in ESF Actuation.Caused by Fan Rub Resulting in Thermal Overload.Fan Deenergized & Control Switch Tagged in pull-to-lock Position + (22:12:25, 12 December 2024)
- ML20127D166 + (22:12:26, 12 December 2024)
- 05000206/LER-1985-010-02, :on 850508,past Failure to Make Continuous 4 H Flow Estimates on Effluent Releases Discovered. Procedures Revised to Require Estimates of Any Flow Through Stack If Fan Flow Indicator R-1254 Inoperable + (22:12:28, 12 December 2024)
- ML20127D163 + (22:12:29, 12 December 2024)
- ML20127D162 + (22:12:30, 12 December 2024)
- ML20127D160 + (22:12:31, 12 December 2024)
- ML20127D157 + (22:12:32, 12 December 2024)
- ML20127D155 + (22:12:33, 12 December 2024)
- 05000296/LER-1985-016-01, :on 850517,during Monthly Test of Diesel Generator 3D,leak Developed at Fuel Line/Filter Weld.Caused by Base Plate Weld Cracks Resulting from Vibration.Cracks Also Found on Diesel Generators 3A & 3B + (22:12:35, 12 December 2024)
- ML20127D152 + (22:12:37, 12 December 2024)
- ML20127D151 + (22:12:37, 12 December 2024)
- ML20127D150 + (22:12:39, 12 December 2024)
- ML20127D149 + (22:12:39, 12 December 2024)
- ML20127D146 + (22:12:40, 12 December 2024)
- ML20127D148 + (22:12:40, 12 December 2024)
- ML20127D145 + (22:12:41, 12 December 2024)
- ML20127D143 + (22:12:43, 12 December 2024)
- ML20127D142 + (22:12:43, 12 December 2024)
- ML20127D141 + (22:12:44, 12 December 2024)
- 05000483/LER-1992-009, :on 920807,discovered That Manual Reactor Trip Breaker Handswitch Contacts Inadequately Tested Per TS 4.3.1.1,Functional Unit 1.Caused by Incomplete Procedure. Procedure Request Form Revised in Jul 1988 + (22:12:46, 12 December 2024)
- IR 05000212/2004029 + (22:12:52, 12 December 2024)
- 05000353/LER-1991-002, :on 910324,various Actuations of Primary Containment & Reactor Vessel Isolation Control Sys Occurred. Caused by Blown Fuse in Div II 125-volt Circuit.New Battery Charger Procedures Written + (22:12:54, 12 December 2024)
- ML20127D136 + (22:12:55, 12 December 2024)
- ML20127D135 + (22:13:07, 12 December 2024)
- ML20127D134 + (22:13:08, 12 December 2024)
- ML20127D132 + (22:13:09, 12 December 2024)
- 05000259/LER-1985-017-01, :on 850514,design Evaluation Determined That Accident Radiation Levels Would Exceed Failure Threshold Teflon Use in Listed Whitney H202 Analyzer Valves Procured from Milton Roy Co.Design Change Issued + (22:13:14, 12 December 2024)
- ML20127D130 + (22:13:16, 12 December 2024)
- ML20127D129 + (22:13:17, 12 December 2024)
- ML20127D126 + (22:13:17, 12 December 2024)
- 05000498/LER-1992-010, :on 920808,standby Train a CCW Pump Started Due Sensed Low Pressure on Miscellaneous Supply Header.Caused by Lack of Procedural Guidance.Surveillance Procedure & Sys Operating Procedure Revised + (22:13:19, 12 December 2024)
- ML20127D124 + (22:13:20, 12 December 2024)
- GO2-83-651, Forwards Updated Const Status Repts as of 830630.Info for Inclusion in NUREG-0030 + (22:13:21, 12 December 2024)
- ML20127D122 + (22:13:23, 12 December 2024)
- ML20127D120 + (22:13:24, 12 December 2024)
- ML20127D121 + (22:13:24, 12 December 2024)
- 05000409/LER-1992-001, :on 920712,1B non-interruptible Bus Rendered Inoperable When Blade from Internal Cooling Fan Fell Onto Electrical Components Inverter.Event Originally Processed as Incident Rept.Update Will Be Submitted + (22:13:26, 12 December 2024)
- ML20127D118 + (22:13:28, 12 December 2024)
- ML20127D117 + (22:13:28, 12 December 2024)