- ML13331A282 + (06:02:23, 11 January 2025)
- ML13331A281 + (06:02:24, 11 January 2025)
- 05000206/LER-1988-009, :on 880526,potential Diesel Loads in Excess of Regulatory Commitments.Caused by Calculation Errors & Inadequate Understanding of Loads on Diesel Generator. Personnel Trained in Proper Methodology + (06:02:27, 11 January 2025)
- 05000206/LER-1988-006, :on 880321,determined That Portions of Backup Nitrogen Sys Design Basis Not Fully Implemented in Design & Installation of Sys.Caused by Procedures Badly Supporting Design Requirements.Procedures Revised + (06:02:31, 11 January 2025)
- ML13331A277 + (06:02:34, 11 January 2025)
- 05000206/LER-1987-006, :on 870513,insp Per IE Info Notice 86-104 Found wide-range Containment Water Level Instrumentation in non-environ Qualification Configuration.Caused by Personnel Error.Training Program Initiated + (06:02:36, 11 January 2025)
- ML13331A275 + (06:02:38, 11 January 2025)
- ML13331A274 + (06:02:42, 11 January 2025)
- 05000206/LER-1988-012-01, :on 880808,determined That Loop a Feedwater Signal Erroneously Low.Possibly Caused by Orifice Plate Being Installed Backwards.Procedure Revised Requiring Highest Flow Be Used for Feedwater Flow Inputs + (06:02:44, 11 January 2025)
- 05000206/LER-1988-013-01, :on 880806,east Main Feedwater Pump Safety Injection Recirculation Valve CV-875A Observed Leaking Feedwater to Refueling Water Storage Tank.Caused by Valve Not Seating Properly in Closed Position + (06:02:46, 11 January 2025)
- 05000206/LER-1987-011-01, :on 880728,spurious Actuation of Containment Isolation Train a Occurred W/Isolation Valves Verified Properly Closed.Caused by Broken Instrument Electrical Solder Connection.Procedures Modified + (06:02:49, 11 January 2025)
- 05000206/LER-1988-011-01, :on 880724,containment Isolation Sys Train a Actuation Occurred Due to Loss of Power to Vital Bus (VB) 1. Caused by Improper Installation of Breaker/Bus Connection. VB 1 Supply Breaker Replaced + (06:02:55, 11 January 2025)
- 05000206/LER-1988-010-01, :on 880625,inadvertent Starting of Diesel Generator 2 Occurred When Inner Compartment Door of Breaker Cubicle Opened.Caused by Personnel Error.Locking Devices to Be Installed on Inner Compartment Doors + (06:02:58, 11 January 2025)
- ML13331A266 + (06:02:59, 11 January 2025)
- ML13331A265 + (06:03:01, 11 January 2025)
- PNO-V-88-042, on 880626,magnitude 4.7 Earthquake Occurred. Telephone Contact Established That Earthquake Not Felt,No Damage Identified,No Releases of Radioactivity Occurred & Seismic Instrumentation Operable & Did Not Respond + (06:03:03, 11 January 2025)
- 05000206/LER-1988-009-01, :on 880526,determined That Max Electrical Load Imposed on Diesel Generators in Excess of Tech Spec 4.4 Limit.Cause Under Investigation.Members Involved Have Reviewed Event & Received Training + (06:03:06, 11 January 2025)
- 05000206/LER-1987-015, :on 871007,determined That ESF Designs Failed to Meet Single Failure Criteria.Cause Re motor-operated Valve MOV-883 Due to Failure to Review Affect of Revised Single Failure Regulatory Guidance + (06:03:09, 11 January 2025)
- 05000206/LER-1988-007-01, :on 880206 & 07,failed to Retain Sample from Ctr Holdup Tank.Caused by Inadequate Chemistry Cintrols. Amend Requiring Verification of Retained Sample Releases Planned & Average of Jan-Mar Values to Be Used + (06:03:11, 11 January 2025)
- ML13331A258 + (06:03:13, 11 January 2025)
- ML13331A257 + (06:03:15, 11 January 2025)
- ML13331A256 + (06:03:17, 11 January 2025)
- 05000206/LER-1988-005-01, :on 880329,review of Tech Spec 4.15 Surveillance Procedures Revealed Two Valves Not Adequately Addressed in Surveillance Program.Caused by Oversight. Procedures Will Be Revised + (06:03:20, 11 January 2025)
- 05000206/LER-1988-006-01, :on 880321,discovered That Backup Nitrogen Sys (Bns) Design Criteria Had Not Been Fully Implemented in Design & Installation of Sys.Caused by Surveillance of Bns Not Being Performed.Changes Instituted + (06:03:23, 11 January 2025)
- ML13331A253 + (06:03:25, 11 January 2025)
- ML13331A252 + (06:03:26, 11 January 2025)
- ML13331A251 + (06:03:28, 11 January 2025)
- 05000206/LER-1988-002-02, :on 880317,Tech Spec Continuous Fire Watch for Containment Interrupted When Equipment Hatch Closed.Caused by Removing Contiguous Area from Combination Post When Hatch Closed.Instructions to Be More Explicit + (06:03:30, 11 January 2025)
- ML13331A249 + (06:03:32, 11 January 2025)
- 05000206/LER-1988-001-02, :on 880225,several Components Requiring Environ Qualification Found Omitted from Equipment Qualification Master List.Caused by Inadequate Methodology During List Generation.Installed Equipment Reviewed + (06:03:35, 11 January 2025)
- ML13331A246 + (06:03:39, 11 January 2025)
- ML13331A245 + (06:03:40, 11 January 2025)
- ML13331A244 + (06:03:42, 11 January 2025)
- ML13331A243 + (06:03:44, 11 January 2025)
- 05000206/LER-1987-018-01, :on 871216,Tech Spec 3.0.3 Voluntarily Entered During Dc Ground Troubleshooting.Caused by Presence of Water Inside Housing of Solenoid.Ground Eliminated by Drying Electrical Connections + (06:03:46, 11 January 2025)
- 05000206/LER-1986-011, :on 860904,main Feedwater Pump Failed.Caused by Loss of Thrust Disk Assembly Preload.New Assembly Instructions Developed to Avoid Loss of Preload.Vibration Amplitude Will Be Monitored + (06:03:49, 11 January 2025)
- 05000206/LER-1986-014, :on 861230,ground Alarm Received in Control Room for Dc Bus 2.Opening Feeder Breaker Constitutes Brief Entry Into Tech Spec 3.0.3.Caused by Moisture in Control Circuitry Junction Box.Ground Cleared + (06:03:52, 11 January 2025)
- 05000206/LER-1987-017-02, :on 870910 & 1201,containment Isolation Valves Loop B Header Would Not Fully Close Upon Demand.Cause Undetermined.Administrative Controls Implemented to Prevent Inadvertent Opening of Valves + (06:03:55, 11 January 2025)
- 05000206/LER-1987-003-01, :on 870310,turbine & Reactor Trips Occurred as Result of Trip Signal in Response to Generator Field Loss. Caused by Electrical Short Resulting from Brush Being Dropped in Main Exciter Commutator Assembly + (06:03:59, 11 January 2025)
- 05000206/LER-1987-016-02, :on 871110,Automatic Switch Co Solenoid Valve Failures Occurred.Caused by Thin Hard Film Between Top of Slug & Housing.Root Cause Evaluation Continuing.Further Testing Performed + (06:04:02, 11 January 2025)
- 05000206/LER-1987-014-02, :on 870626,determined That Battery Weekly Surveillance Not Performed Prior to Mode Change,Contrary to Tech Spec 4.0.4.Caused by Personnel Error.Individual Involved Reinstructed + (06:04:04, 11 January 2025)
- 05000206/LER-1987-005, :on 870324,nuclear Instrumentation Sys Power Range Channel 1207 Declared Inoperable.Channel Placed in Trip Condition.On 870428 & 29,Channel 1207 Automatically Reset from Trip to Inoperable Condition + (06:04:07, 11 January 2025)
- ML13331A234 + (06:04:10, 11 January 2025)
- 05000206/LER-1987-015-02, :on 871007,determined That Engineered Safety Sys Design Failed to Meet Single Criteria.Caused by Newly Identified time-dependent Single Failure Susceptibilty. Special Operator Training Provided + (06:04:12, 11 January 2025)
- ML13331A232 + (06:04:14, 11 January 2025)
- ML13331A231 + (06:04:16, 11 January 2025)
- 05000206/LER-1987-013-01, :on 870902,redundant Pump G-002B Not Tested Prior to Disabling of auto-start Capability of Pump G-002A During Calibr of Hydrazine Storage Tank Level Transmitter. Caused by Personnel Error.Personnel Counseled + (06:04:19, 11 January 2025)
- ML13331A229 + (06:04:22, 11 January 2025)
- 05000206/LER-1987-012-02, :on 870825,containment Air Luck Hatch Did Not Fully Close Due to Hatch Drive Failure,Resulting in Brief Breach of Containment Integrity.Caused by Broken Master Link.Broken Master Link Replaced + (06:04:24, 11 January 2025)
- 05000206/LER-1987-007-02, :on 870713,discovered Boric Acid Storage Tank Level Instrumentation Monthly Functional Test Performed Delinquently.Caused by Failure of Planner to Include Test in Tracking Sys.Planner Counseled + (06:04:29, 11 January 2025)
- 05000206/LER-1986-007, :on 870729,main Feedwater Regulating Valves Closed Resulting in Decrease in Steam Generator Water Levels to 5%.On 870730,steam Flow Signals Failed Low & Unit Shutdown Per Tech Specs.Event Under Review + (06:04:33, 11 January 2025)