- PNO-I-80-062, on 800418,leakage Flow Path to Ohio River Was Found to Have Existed Past Shut But Leaking Valves.Inventory Showed Total Loss Less than 4,000 Gallons from Flow of 1-2 Gallons Per Minute + (03:13:27, 1 January 2025)
- ML19323D037 + (03:13:28, 1 January 2025)
- ML19323D033 + (03:13:35, 1 January 2025)
- 05000333/LER-1980-035-03, /03L-0:on 800415,during Normal Operations,Rhr Sys Discharge (10-MOV-67) to Radwaste Would Not Open in Response to Open Signal.Caused by Improperly Set Torque Bypass Limit Switch.Limit Switches Adjusted + (03:13:38, 1 January 2025)
- ML19323D031 + (03:13:40, 1 January 2025)
- 05000333/LER-1980-035, Forwards LER 80-035/03L-0 + (03:13:43, 1 January 2025)
- ML19323D026 + (03:13:59, 1 January 2025)
- ML19323D025 + (03:14:01, 1 January 2025)
- ML19323D024 + (03:14:02, 1 January 2025)
- ML19323D023 + (03:14:03, 1 January 2025)
- ML19323D022 + (03:14:04, 1 January 2025)
- ML19323D020 + (03:14:06, 1 January 2025)
- ML19323D019 + (03:14:07, 1 January 2025)
- ML19323D018 + (03:14:08, 1 January 2025)
- ML19323D017 + (03:14:10, 1 January 2025)
- ML19323D014 + (03:14:15, 1 January 2025)
- ML19323D013 + (03:14:17, 1 January 2025)
- ML19323D012 + (03:14:18, 1 January 2025)
- ML19323D011 + (03:14:19, 1 January 2025)
- ML19323D007 + (03:14:24, 1 January 2025)
- 05000327/LER-1980-039-01, /01T-0:on 800427,two-inch Containment Spray Air Test Lines Were Analyzed Using Incorrect Outside Diameter for Piping Involved.Caused by Input Error Not Found During Checking.Piping Analyzed Using Correct Value + (03:14:27, 1 January 2025)
- ML19323D005 + (03:14:40, 1 January 2025)
- ML19323D004 + (03:14:43, 1 January 2025)
- ML19323D003 + (03:14:45, 1 January 2025)
- ML19323D001 + (03:14:51, 1 January 2025)
- 05000327/LER-1980-039, Forwards LER 80-039/01T-0 + (03:15:00, 1 January 2025)
- ML19323C998 + (03:15:02, 1 January 2025)
- ML19323C997 + (03:15:05, 1 January 2025)
- 05000366/LER-1980-062-03, /03L-0:on 800419,w/reactor in Cold Shutdown,During Primary Containment Isolation Sys Operability Test,Vacuum Breaker Valve 2T48-F323E Failed to Open When Control Switch Was Actuated + (03:15:29, 1 January 2025)
- ML19323C992 + (03:15:41, 1 January 2025)
- ML19323C991 + (03:15:43, 1 January 2025)
- ML19323C990 + (03:15:46, 1 January 2025)
- ML19323C989 + (03:15:47, 1 January 2025)
- ML19323C987 + (03:15:56, 1 January 2025)
- 05000366/LER-1980-062, Forwards LER 80-062/03L-0 + (03:16:02, 1 January 2025)
- ML19323C984 + (03:16:05, 1 January 2025)
- ML19323C983 + (03:16:08, 1 January 2025)
- ML19323C982 + (03:16:10, 1 January 2025)
- ML19323C979 + (03:16:18, 1 January 2025)
- ML19323C978 + (03:16:20, 1 January 2025)
- 05000338/LER-1980-039-03, /03L-0:on 800417,Channel III Steamline Pressure Protection Bistable for P2-P1 Initiation Failed to Trip & Would Not Respond to Input During Monthly Surveillance Test. Caused by Defective Signal Comparator Card in Loop + (03:16:23, 1 January 2025)
- 05000366/LER-1980-067-03, /03L-0:on 800422,during Instrument Check,Drywell a H2-O2 Analyzer Was Giving Erroneous Readings.Caused by Defective Cell.Cell Was Replaced.Analyzer Was Recalibr & Placed Into Svc + (03:16:28, 1 January 2025)
- ML19323C975 + (03:16:31, 1 January 2025)
- ML19323C973 + (03:16:32, 1 January 2025)
- ML19323C971 + (03:16:34, 1 January 2025)
- ML19323C970 + (03:16:37, 1 January 2025)
- 05000366/LER-1980-067, Forwards LER 80-067/03L-0 + (03:16:42, 1 January 2025)
- 05000338/LER-1980-039, Forwards LER 80-039/03L-0 + (03:17:13, 1 January 2025)
- ML19323C965 + (03:17:18, 1 January 2025)
- 05000366/LER-1980-078-03, /03L-0:on 800419,while Performing Leakage Control Sys Test,Initiation Permissive Contacts Failed to Open. Caused by Relay Failure.Relay Was Replaced & Retested W/ Satisfactory Results + (03:17:57, 1 January 2025)
- ML19323C963 + (03:18:02, 1 January 2025)