Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20197G752 + (June 8, 1984)
- 05000373/LER-1984-027, :on 840520,offgas Hydrogen Sample Not Performed Until 5.5 H After Power Drop.Caused by Rad/Chem Not Notified to Begin 4 H Sampling.Shift Supervisor Will Rept to Shift Engineer Re Plant Evolution + (June 8, 1984)
- 05000296/LER-1984-006-02, :on 840517,two Welds on Jet Pump Instrument Nozzles Determined to Need Repair.Caused by High Carbon Content,Leading to More Susceptibility for Sensitization Areas.Weld Will Be Repaired Prior to Startup + (June 8, 1984)
- 05000254/LER-1984-008-03, :on 840511,concern Raised Re Adequacy of 125- Volt Station Batteries Relative to Dc Load.Analysis Revealed Batteries Unable to Bring Units to Cold Shutdown W/O Some Nonessential Loads Shed.Battery Load Reduced + (June 8, 1984)
- 05000373/LER-1984-026, :on 840517,Transco Personnel Identified Unsealed Conduit Penetration Firestop.Unsealed Circuit Not Identified in Prior Insps.Repairs & Insps Completed 840522 + (June 8, 1984)
- 05000362/LER-1984-015-01, :on 840427,0505 & 07,analysis of RCS Sample Indicated That Specific Activity Exceeded 1.0 Uci/G Dose Equivalent I-131.Cause Not Stated.Personnel Instructed to Perform Sampling within Required 4 H Period + (June 8, 1984)
- 05000362/LER-1984-013, :on 840330 & 0401,following Reactor Shutdown for Maint,Rcs Sample Analysis Indicated That RCS Specific Activity Exceeded 1.0 Uci/G Dose Equivalent I-131.Cause Indicative of Iodine Spiking Following Power Change + (June 8, 1984)
- 05000220/LER-1984-005, :on 840509,during Refueling Outage,Spurious Trip of Intermediate Range Monitors Occurred on Monitors 11 & 16.Caused by Electromagnetic Interference Due to Welding in Drywell.No Corrective Action Taken + (June 8, 1984)
- 05000373/LER-1984-025, :on 840517,trapdoor on Auxiliary Bldg Roof Neither Posted as High Radiation Area Nor Secured to Prevent Unauthorized Entry.Entrance Posted as High Radiation Area, Access Controlled & Door Secured + (June 8, 1984)
- 05000272/LER-1984-011-01, :on 840503,fire Suppression Pump Removed from Svc for 18-month Surveillance Requirements & on 840509,while Returning Pump to Svc,Pump Discharge Valve Would Not Open. Caused by Broken Stem.Stem & Disc Replaced + (June 8, 1984)
- 05000251/LER-1984-007-01, :on 840509,during Scheduled Refueling Outage, Three 480-volt Load Ctr Feeder Breakers Tripped.Caused by Procedural Deficiency.Power Restored to Three 480-volt Load Ctrs & Procedure Revised + (June 8, 1984)
- 05000327/LER-1984-034, :on 840509,valve 1-67-537B Found Mispositioned When Valves 1-FCV-67-123 & 1-FCV-67-124 Opened.Caused by Valve Being Closed Since 840424.Valve Throttled to Proper Position + (June 8, 1984)
- 05000311/LER-1984-013, :on 840511,reactor Trip Occurred While Troubleshooting & Calibr Steam Generator narrow-range Level Recorder 22.Caused by Personnel Error.Troubleshooting/Calibr Check Off Sheets Provided to Reduce Accidents + (June 8, 1984)
- 05000219/LER-1984-010, :on 840510,for Number of Iterations,Fuel Pool Gates Moved Over Irradiated Fuel Bundles in Violation of Tech Spec.Caused by Procedural Error.Handling Procedure Will Be Revised + (June 8, 1984)
- 05000397/LER-1984-042, :on 840517,reactor Manually Shut Down Due to Loss of Control of Vessel Water.Caused by Malfunction of Mechanical Linkage from Servo Control Motor.Linkage Repositioned & Refastened + (June 8, 1984)
- ML20199F706 + (June 8, 1984)
- ML20138Q000 + (June 8, 1984)
- ML20094M482 + (June 8, 1984)
- ML20127B722 + (June 8, 1984)
- ML20136B491 + (June 8, 1984)
- ML19271F410 + (June 8, 1984)
- ML18026B190 + (June 8, 1984)
- ML14192A478 + (June 8, 1984)
- ML13310B523 + (June 8, 1984)
- ML13310B530 + (June 8, 1984)
- ML17298B060 + (June 8, 1984)
- ML13310B533 + (June 8, 1984)
- ML13310B532 + (June 8, 1984)
- ML20117L769 + (June 8, 1984)
- ML20127B726 + (June 8, 1984)
- ML17346A565 + (June 8, 1984)
- ML19270C233 + (June 8, 1984)
- ML20099J140 + (June 9, 1984)
- ML20099J129 + (June 9, 1984)
- ML20099J119 + (June 9, 1984)
- ML20091Q832 + (June 9, 1984)
- ML20091P652 + (June 9, 1984)
- ML20106A384 + (June 9, 1984)
- ML20106A379 + (June 9, 1984)
- ML20106A373 + (June 9, 1984)
- ML20106A370 + (June 9, 1984)
- ML20106A371 + (June 9, 1984)
- ML20106A366 + (June 9, 1984)
- ML20106A360 + (June 9, 1984)
- ML20136F925 + (June 9, 1984)
- ML20136F926 + (June 9, 1984)
- ML20132E226 + (June 9, 1984)
- ML20091R869 + (June 10, 1984)
- ML20260J612 + (June 10, 1984)
- 05000305/LER-1984-011, :on 840510 & 11,shield Bldg Recirculation Fan 1A Found Operating W/Associated Dampers Open.No Apparent Cause Evident.Auxiliary Contact on Fan Motor Starter Replaced + (June 10, 1984)
- ML18038A677 + (June 11, 1984)
- ML17054A822 + (June 11, 1984)
- ML17054A821 + (June 11, 1984)
- ML17298B051 + (June 11, 1984)
- ML17298B052 + (June 11, 1984)
- ML20070A159 + (June 11, 1984)
- ML20095J472 + (June 11, 1984)
- ML20093A001 + (June 11, 1984)
- ML20092P405 + (June 11, 1984)
- ML20092P401 + (June 11, 1984)
- ML20092P340 + (June 11, 1984)
- ML20092P182 + (June 11, 1984)
- ML20092M730 + (June 11, 1984)
- ML20092L361 + (June 11, 1984)
- ML20092K584 + (June 11, 1984)