- 05000346/LER-1984-004, :on 840321,survey Revealed Fire Doors Did Not Meet NFPA 80 Stds of 1/8 Inch Frame & Door & 3/4 Inch Frame & Bottom of Door Max Clearance.Cause Not Specified.Maint Repair Order Prepared + (April 27, 1984)
- 05000280/LER-1984-007-06, :on 840328,instrument Technicians Determined That Main Feed Regulating Valves Would Not Have Tripped Closed Upon Receipt of Feedwater Isolation Signal.Caused by Unapproved Work Procedure.Procedure Corrected + (April 27, 1984)
- 05000369/LER-1984-010, :on 840328,diesel Generator 1B Experienced Invalid Automatic Start.Caused by Severe Weather.Blackout Signal Cleared & Diesel Generator Not Loaded.Generator Shut Down After Operating 6 Minutes + (April 27, 1984)
- 05000278/LER-1984-003-01, :on 840329,core Spray Logic Fuse 14A-F2B Blew During Instrument Surveillance Testing Due to Shorted Socket on Indicating Light 14A-DS26B.Shorted Socket Removed from Logic Circuit & Fuse Replaced + (April 27, 1984)
- 05000277/LER-1984-007, :on 840403,reactor Water Cleanup Sys Isolated on High Temp.Caused by Loss of Electrical Power to Temp Indicating Switch TIS-12-99.Maint Shorted Hot Lead to Ground Causing Fuse 12A-F1 to Blow.Fuse Replaced + (April 27, 1984)
- 05000277/LER-1984-006, :on 840328,routine Sample of Water Taken from High Pressure Svc Water Piping Discovered Contaminated. Caused by HX Leaking Into Discharge Pond Via Piping Sys. HX Repaired + (April 27, 1984)
- 05000327/LER-1984-022, :on 840330 & 0409,high Radiation Alarm Actuated,Causing Containment Ventilation Isolation.Caused by Electromagnetic Interference Spike & Inadvertent Circuit Input Grounding.Alarm Reset + (April 27, 1984)
- 05000328/LER-1984-005-03, :on 840329,Surveillance Instruction 269, Channel Function Test of ESF Instrumentation for Automatic Switchover to Containment Sump, Not Completed Per Tech Specs.Scheduling & Tracking Program Modified + (April 27, 1984)
- 05000302/LER-1983-003-03, Containment Isolation Valve MUV-41 Declared Inoperable.Caused by Stripped Gear Train Due to Lack of Lubrication.Gears Replaced & Lubricated + (April 27, 1984)
- 05000361/LER-1984-022, :on 840330 & 0410,control Room Isolation Sys Train Spuriously Actuated from Spike on Control Room Airborne Radiation Monitor.Caused by Spurious Electrical Spikes.No Corrective Action Planned + (April 27, 1984)
- 05000395/LER-1984-018, :on 840323,during Snubber Insp of Steam Generator Blowdown sys,11 Supports Would Not Maintain Design Function & Nine of 11 Failed Functional Test.Caused by Sys Transients.Snubbers Repaired or Replaced + (April 27, 1984)
- ML20093K454 + (April 27, 1984)
- ML19276B033 + (April 27, 1984)
- ML19276B035 + (April 27, 1984)
- ML18051A877 + (April 27, 1984)
- L-84-112, Application for Amend to Licenses DPR-31 & DPR-41,changing Tech Specs to Add Definition of Heavy Loads & Prohibit Travel of Heavy Loads Over Irradiated Fuel Assemblies in Spent Fuel Pool + (April 27, 1984)
- ML17320B051 + (April 27, 1984)
- GO2-84-272, Advises That Reactor Coolant Disolved Gas Grab Sampling Capability Installed,Tested & Operational,Per Condition of Amend 1 to License NPF-21.Procedures Prepared & Appropriate Personnel Trained + (April 27, 1984)
- L-84-110, Advises That Addl Info Re Inservice Testing Program for Pumps & Valves Will Be Submitted by 840718,in Response to 840412 Request + (April 27, 1984)
- ML16340E336 + (April 27, 1984)
- ML14051A525 + (April 27, 1984)
- ML17255A820 + (April 27, 1984)
- ML13305A566 + (April 27, 1984)
- ML17298B010 + (April 27, 1984)
- ML17298B017 + (April 27, 1984)
- ML17298B026 + (April 27, 1984)
- ML20084G853 + (April 27, 1984)
- ML13310B401 + (April 27, 1984)
- 05000296/LER-1979-005, Updated LER 79-005/01T-2:on 790506,RHR Svc Water Supply to RHR HX 2B Isolated Standby Coolant Supply.Caused by Lack of Administrative Control Over Sys Cross Connect Valves. Controls Improved + (April 27, 1984)
- ML20084E733 + (April 28, 1984)
- ML20084E430 + (April 28, 1984)
- ML20084E133 + (April 28, 1984)
- ML20264E545 + (April 28, 1984)
- ML20264E057 + (April 28, 1984)
- ML20262B652 + (April 28, 1984)
- ML20260A832 + (April 28, 1984)
- ML20265E449 + (April 28, 1984)
- ML20153E149 + (April 29, 1984)
- ML20197G411 + (April 29, 1984)
- ML20261K052 + (April 29, 1984)
- Regulatory Guide 5.11 + (April 30, 1984)
- ML17054B164 + (January 31, 1984)
- ML17215A369 + (April 30, 1984)
- ML17215A368 + (April 30, 1984)
- ML17054B167 + (April 30, 1984)
- NRC Generic Letter 1984-12 + (April 30, 1984)
- ML18018B694 + (April 30, 1984)
- ML18018B693 + (April 30, 1984)
- ML18026A962 + (April 30, 1984)
- ML18092A200 + (April 30, 1984)
- ML18092A199 + (April 30, 1984)
- ML18051A879 + (April 30, 1984)
- ML18051A876 + (April 30, 1984)
- NRC Generic Letter 84-12, Compliance with 10 CFR 61 and Implementation of Radiological Effluent Tech Specs, Attendant Process Control Program + (April 30, 1984)
- ML20084R865 + (April 30, 1984)
- ML20084R162 + (April 30, 1984)
- ML20084R090 + (April 30, 1984)
- ML20084Q616 + (April 30, 1984)