- 05000368/LER-1988-023-01, :on 880219,inoperability of Mechanical Snubber on Main Steam Supply Piping Discovered.Caused by High Dynamic Loading of Piping & Snubber Due to Water Entrainment in Steam Piping.Snubber Replaced + (ML20248A334)
- ML20248A335 + (ML20248A335)
- ML20248A336 + (ML20248A336)
- ML20248A340 + (ML20248A340)
- ML20248A341 + (ML20248A341)
- U-603003, Forwards Signed Consent to Confirmatory Order Modifying CPS License by Incorporating Changes to Proposed Consent to Confirmatory Order Included in NRC + (ML20248A342)
- ML20248A344 + (ML20248A344)
- ML20248A345 + (ML20248A345)
- ML20248A347 + (ML20248A347)
- IR 05000313/1989018 + (ML20248A348)
- ML20248A350 + (ML20248A350)
- ML20248A352 + (ML20248A352)
- ML20248A353 + (ML20248A353)
- ML20248A357 + (ML20248A357)
- ML20248A358 + (ML20248A358)
- ML20248A360 + (ML20248A360)
- 05000352/LER-1989-026, :on 890419,four Emergency Diesel Generators Inoperable.Caused by Deficiencies in Physical Separation Between Class 1E Internal Wires & Internal Nonclass 1E Wires.Wrapping of Appropriate Wires Initiated + (ML20248A363)
- ML20248A364 + (ML20248A364)
- ML20248A366 + (ML20248A366)
- JAFP-89-0689, Responds to NRC Re Violations Noted in Rept 50-333/89-80.Corrective Actions:Util Established Formal Preventive Maint Program in 1984 Which Includes 600-volt Class 1E Circuit Breakers,Motor Starters & Transformers + (ML20248A368)
- ML20248A372 + (ML20248A372)
- ML20248A374 + (ML20248A374)
- ML20248A379 + (ML20248A379)
- ML20248A385 + (ML20248A385)
- ML20248A387 + (ML20248A387)
- 05000266/LER-1989-005, :on 890503,inoperability of Low Temp Overpressure Protection Sys Using Nitrogen Gas Discovered. Caused by Inadequate post-mod Testing.Nitrogen Regulators Moved to Location Near PORVs + (ML20248A389)
- IR 05000271/1989012 + (ML20248A392)
- ML20248A393 + (ML20248A393)
- ML20248A395 + (ML20248A395)
- ML20248A396 + (ML20248A396)
- BECO-89-142, Responds to NRC Re Violations & Proposed Imposition of Civil Penalty from Insp Rept 50-293/89-95. Corrective Action:Two Responsible Util Operators Suspended Because Breakers Incorrectly Positioned for Test + (ML20248A401)
- ML20248A403 + (ML20248A403)
- 05000267/LER-1989-018, :on 890825,leak in Main Steam Ringheader of One of Loop I Steam Generator Modules Discovered & on 890827,37 Crack Indications Found in Inconel Ringheaders.Investigation in Progress.Plant Shut Down on 890829 + (ML20248A405)
- ML20248A406 + (ML20248A406)
- ML20248A409 + (ML20248A409)
- 05000266/LER-1989-006, :on 890505,automatic Actuation of motor-driven Auxiliary Feedwater Pumps Occurred.Caused by Cognitive Personnel Error Concerning Projected Plant Conditions.Sys Response Evaluated + (ML20248A410)