Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20235S837 + (ML20235S837)
- ML20235S838 + (ML20235S838)
- IR 05000454/1987024 + (ML20235S840)
- ML20235S841 + (ML20235S841)
- ML20235S844 + (ML20235S844)
- ML20235S845 + (ML20235S845)
- ML20235S852 + (ML20235S852)
- ML20235S853 + (ML20235S853)
- ML20235S854 + (ML20235S854)
- ML20235S857 + (ML20235S857)
- ML20235S858 + (ML20235S858)
- ML20235S861 + (ML20235S861)
- ML20235S862 + (ML20235S862)
- ML20235S863 + (ML20235S863)
- 05000254/LER-1987-016-06, :on 870912,determined That Measured Combined Leakage Rate from All Penetrations & Valves,Excluding MSIV, Exceeded Tech Spec Limits.Cause Not Yet Determined. Investigation Underway + (ML20235S868)
- ML20235S870 + (ML20235S870)
- ML20235S873 + (ML20235S873)
- ML20235S883 + (ML20235S883)
- 05000348/LER-1987-011, :on 870611,results of Testing of Fire Dampers Declared Inoperable on 870605,determined That Dampers Would Not Fully Close & Latch W/Air Flow.Caused by Design Deficiency.Design Change Being Developed + (ML20235S884)
- ML20235S889 + (ML20235S889)
- ML20235S891 + (ML20235S891)
- ML20235S892 + (ML20235S892)
- 05000366/LER-1987-004-02, :on 870616,HPCI Found Incapable of Performing Intended Safety Function.During 870618 Testing,Two Hpic Steam Supply Valve Isolations Occurred.Cause Under Investigation + (ML20235S895)
- 05000261/LER-1987-019-01, :on 870616,discovered That Thot & Tcold Reversed on RCS Loop 1.Caused by Inadvertent Reversal During Repair Work on Thot & Tcold Connections Inside Containment. Circuits Corrected + (ML20235S896)
- ML20235S899 + (ML20235S899)
- ML20235S900 + (ML20235S900)
- AECM-89-0030, Responds to NRC Bulletin 88-007,Suppl 1, Power Oscillations in Bwrs. Off-Normal Emergency Procedure 05-1-02-III-3, Decrease in Recirculation Sys Flow Rate, Changed to Incorporate BWR Owners Group Recommendations + (ML20235S904)
- 05000327/LER-1987-028, :on 870611,determined That Both Control Air Trains Could Be Lost in Event of Offsite Power Loss.Caused by Design Deficiency.Jumpers Installed Around sealed-in Contacts to Provide Automatic Reset + (ML20235S907)
- NRC-87-0110, Informs of Corrective Actions Taken Re 870626 Unplanned Mode Change Discussed at 870707 Meeting W/Nrc.Actions Taken Include Disciplinary Actions for Responsible Personnel,Exam Developed & Will Be Administered by 870801 + (ML20235S909)
- ML20235S911 + (ML20235S911)
- ML20235S912 + (ML20235S912)
- 05000254/LER-1987-019-04, :on 870912,containment Leakage Determined to Be in Excess of Tech Spec 3.7.A.2.b Limit.Cause Not Determined. Investigation Will Determine Corrective Actions + (ML20235S913)
- NLS8700352, Forwards Util Submitting Util 1987 Emergency Preparedness Exercise Objectives.Encl Info Not for Release to PDR Before 871008 + (ML20235S917)
- NLS8700341, Forwards Emergency Preparedness Objectives for 871007 Exercise.Util Attempted to Address Areas Which Would Evaluate Emergency Response Organization Capabilities. Objectives Developed in Conjunction W/States of Ne & Mo + (ML20235S920)
- B12578, Responds to NRC 870519 Concerns Over Implementation of Commitments (Ref Insp Rept 50-213/87-08).Efforts Underway to Improve Link Between Commitment Tracking & Work Assignment Sys.Util Performance Expected to Improve + (ML20235S921)
- ML20235S922 + (ML20235S922)
- ML20235S925 + (ML20235S925)
- ML20235S927 + (ML20235S927)
- ML20235S929 + (ML20235S929)
- ML20235S931 + (ML20235S931)
- ML20235S934 + (ML20235S934)
- U-601049, Forwards Proposed Mod to NPDES Permit,Changing Design Max Flow for Outfall 003 Water Treatment Wastes + (ML20235S935)
- ML20235S936 + (ML20235S936)
- ML20235S938 + (ML20235S938)
- U-601050, Advises That Util Endorses BWR Owners Group 870820 Comments on Draft NUREG-1150, Reactor Risk Ref Document + (ML20235S941)
- ML20235S942 + (ML20235S942)
- ML20235S947 + (ML20235S947)
- SNRC-1556, Shoreham Nuclear Power Station Annual Operating Rept 1988 + (ML20235S948)
- ML20235S950 + (ML20235S950)
- ML20235S951 + (ML20235S951)
- ML20235S954 + (ML20235S954)