Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20215F236 + (ML20215F236)
- ML20215F237 + (ML20215F237)
- ML20215F241 + (ML20215F241)
- ML20215F242 + (ML20215F242)
- ML20215F245 + (ML20215F245)
- ML20215F253 + (ML20215F253)
- ML20215F254 + (ML20215F254)
- ML20215F258 + (ML20215F258)
- IR 05000456/1986049 + (ML20215F259)
- ML20215F265 + (ML20215F265)
- ML20215F267 + (ML20215F267)
- 05000409/LER-1986-028, :on 860913,reactor Scrammed When Turbine Stop Valve Opened Later than Required by Procedure.Caused by Operator Error.Procedure Change Initiated to Tie Turbine & Plant Startup Procedures Together + (ML20215F270)
- ML20215F273 + (ML20215F273)
- ML20215F275 + (ML20215F275)
- ML20215F277 + (ML20215F277)
- ML20215F278 + (ML20215F278)
- ML20215F279 + (ML20215F279)
- 05000409/LER-1986-027, :on 860910,reactor Tripped Due to Indication on source-range Nuclear Instrumentation Channel 2 Decreasing Before Channel Reached Full Scale.Caused by Undersized Output Tube Pins.Tube Replaced + (ML20215F281)
- ST-HL-AE-1760, Forwards Procedures Used to Estimate Core Damage in Response to SER Confirmatory Item 18 Re NUREG-0737,Item Ii.B 3, Post-Accident Sampling Sys + (ML20215F282)
- ML20215F283 + (ML20215F283)
- ML20215F287 + (ML20215F287)
- ML20215F288 + (ML20215F288)
- ML20215F289 + (ML20215F289)
- ML20215F290 + (ML20215F290)
- BSEP-86-1370, Revised Emergency Procedures,Including Rev 4 to PEP-02.6.17 Re Administrative & Logistics Manager,Rev 9 to PEP-03.4.1 Re Initial Dose Projections & Rev 17 to PEP-App a Re Emergency Response Resources + (ML20215F294)
- ML20215F296 + (ML20215F296)
- IR 05000327/1986026 + (ML20215F297)
- ML20215F298 + (ML20215F298)
- ML20215F299 + (ML20215F299)
- ML20215F300 + (ML20215F300)
- ML20215F301 + (ML20215F301)
- IR 05000424/1986121 + (ML20215F302)
- ML20215F305 + (ML20215F305)
- ML20215F306 + (ML20215F306)
- ML20215F307 + (ML20215F307)
- ML20215F311 + (ML20215F311)
- 3F1086-07, Monthly Operating Rept for Sept 1986 + (ML20215F315)
- IR 05000327/1986046 + (ML20215F316)
- 05000219/LER-1987-025, :on 870507,4 of 10 Primary Containment Vent & Purge Valves Found to Have Max Opening Stroke Greater than 30 Degrees.Caused by Procedural Inadequacy.Instructions Will Be Written Re New Valve Measuring Method + (ML20215F318)
- ML20215F320 + (ML20215F320)
- ML20215F321 + (ML20215F321)
- ML20215F322 + (ML20215F322)
- 05000282/LER-1986-006-01, :on 860907,simultaneous Inoperability of One Diesel Generator & One Diesel Cooling Water Pump Occurred. Caused by Rupture of Brass Tubing.Tubing Replaced W/Stainless Steel + (ML20215F326)
- 05000298/LER-1987-011, :on 870517,while Conducting Monthly Turbine Valve Testing,Unplanned Actuation of Reactor Protection Sys & Containment Isolation Valve Groups 2,3 & 6 Initiated. Caused by Personnel Error.Procedure Revised + (ML20215F331)
- 05000440/LER-1986-085, Forwards LERs 86-083,86-084 & 86-086.LER 86-085 Will Be Sent Under Separate Cover + (ML20215F332)
- 05000338/LER-1987-011, :on 870515,core Alterations Initiated W/O Operable Charging Pump & on 870516,charging Pump C Discovered Inoperable.Caused by Personnel Error.Root Cause & Corrective Actions Under Evaluation + (ML20215F334)
- ML20215F336 + (ML20215F336)
- ML20215F338 + (ML20215F338)
- ML20215F340 + (ML20215F340)
- ML20215F342 + (ML20215F342)
- ML20215F344 + (ML20215F344)