Decemb r 17, 1986 Docket No. 50-267 Mr. R. O. Williams, Jr.

Vice President, Nuclear Operations Public Service Company of Colorado P. O. Box 840 Denver, Colorado 80201-0840

Dear- Mr.- Williams:

SUBJECT:

PREVENTIVE MAINTENANCE PROGRAM FOR CONTROL R0D DRIVE AND ORIFICING ASSEMBLIES AT FORT ST. VRAIN We have reviewed your submittals dated February 3 and September 19, 1986 (P-86078 and P-86547) concerning your preventive maintenance-program for the control rod drive and orificing assemblies (CRD0As) at the Fort St. Vrain Nuclear Generating Station. We conclude that the proposed program represents a well-planned and comprehensive approach to monitoring the operational status of the CRD0As. Therefore, we find your proposed program acceptable. Our Safety Evaluation is enclosed.

Sincerely, original signed by Kenneth L. Heitner, Project Manager Standardization and Special Projects Directorate Division of PWR Licensing-B Office of Nuclear Reactor Regulation

Enclosure:

, DISTRIBUTION:

As stated 1 Docket~'~"#

File .3 PNoonan NRC PDR KHeitner cc w/ enclosure: Local PDR 0 Lynch

'See next page PBSS Reading HBerkow FMiraglia 0GC-Bethesda 8612230347 861217 EJordan DR ADOCK 0500 7 p .

BGrimes JPartlow HThomspon ACRS (10) h PBSS PE S' PBS$ )

loonan KHeitner:cw 0 h HBerbw 12/9/86 12/t1/86. 12 f/86 12/yB6 l

I y,

.f %y y, UNITED STATES y

(k

' 3"( /p j p,

NUCLEAR REGULATORY COMMISSION

, ,. WASH;NG TON, D. C. 20555

%, - / December 17, 1986 Docket No. 50-267 Mr. R. O. Williams, Jr.

Vice President, Nuclear Operations Public Service Company of Colorado P. O. Box 840 Denver, Colorado 80201-0840

Dear Mr. Williams:

SUBJECT:

PREVENTIVE MAINTENANCE PROGRAM FOR CONTROL R0D DRIVE AN ASSEMBLIES AT FORT ST. VRAIN We have reviewed your submittals dated February 3 and September 19, 1986 1

(P-86078 and P-86547) concerning your preventive maintenance program for the control rod drive and orificing assemblies (CRD0As) at the Fort St. Vrain Nuclear Generating Station. We conclude that the proposed program represents a well-planned and comprehensive approach to monitoring the operational status of the CRD0As. Therefore, we find your proposed program acceptable. Our Safety Evaluation is enclosed.

=.

Sincerely, Kenneth L. Heitner, Project Manager Standardization and Special Projects Directorate Division of PWR Licensing-B Office of Nuclear Reactor Regulation

Enclosure:

As stated cc w/ enclosure:

See next page

_____a

Mr. R. O. Williams

, Public Service Company of Colorado Fort St. Vrain cc:

Mr. D. W. Warembourg, Manager Albert J. Hazle, Director Nuclear Engineering Division Public Service Company Radiation Control Division Department of Health of Colorado P. O. Box 840 4210 East lith Avenue Denver, Colorado 80220 Denver, Colorado 80201 Mr. David Alberstein,14/159A Mr. J. W. Gahm, Manager GA Technologies, Inc.

Post Office Box 85608 Nuclear Production Division San Diego, California 92138 Public Service Company of Colorado 16805 Weld County Road 19-1/2 Platteville, Colorado 80651 Mr. H. L. Brey, Manager Nuclear Licensing and Fuel Division Mr. P. F. Tomlinson, Manager Public Service Company of Colorado Quality Assurance Division

' P. O. Box 840 Public Service Company of Colorado Denver, Colorado 80201 16805 Weld County Road 19-1/2 Platteville, Colorado 80651 Senior Resident Inspector U.S. Nuclear Regulatory Commission Mr. R. F. Walker P. 0 Box 840 Public Service Company of Colorado Platteville, Colorado 80651 Post Office Box 8a0 Denver, Colorado 92138 Kelley, Stansfield & 0'Donnell Public Service Company Building Commitment Control Program Room 900 Coordinator 550 15th Street Public Service Company of Colorado Denver, Colorado 80202 2420 W. 26th Ave. Suite 100-D Denver, Colorado 80211

-~

Regional Administrator, Region IV U.S. Nuclear Regulatory Commission E 611 Ryan Plaza Drive, Suite 1000 Arlington, Texas 76011 Chairman, Board of County Commissioners of Weld County, Colorado Greeley, Colorado 80631 l Regional Representative 1 Radiation Programs Environmental Protection Agency l 1 Denver Place 999 18th Street, Suite 1300 Denver, Colorado 80202-2413 l