Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20213G637 + (ML20213G637)
- ML20213G638 + (ML20213G638)
- ML20213G639 + (ML20213G639)
- ST-HL-AE-1788, Forwards Amend 56 to FSAR for South Texas Project Units 1 & 2 + (ML20213G640)
- ML20213G646 + (ML20213G646)
- 05000219/LER-1986-026, :on 861011,reactor Vessel Low Water Level Scram Occurred During Excess Flow Check Valve Testing.Caused by Inadequate Administrative Controls.Administrative Controls Will Be Revised + (ML20213G647)
- ML20213G650 + (ML20213G650)
- ML20213G651 + (ML20213G651)
- ML20213G652 + (ML20213G652)
- ML20213G655 + (ML20213G655)
- ML20213G656 + (ML20213G656)
- ML20213G660 + (ML20213G660)
- ML20213G661 + (ML20213G661)
- ML20213G662 + (ML20213G662)
- 05000263/LER-1986-026, :on 861014,portions of Group II Primary Containment Isolation Sys & Standby Gas Treatment Sys Started W/O Valid Initiation Signal.Caused by Blown Fuse. Fuse Replaced + (ML20213G663)
- ML20213G666 + (ML20213G666)
- ML20213G669 + (ML20213G669)
- ML20213G671 + (ML20213G671)
- ML20213G672 + (ML20213G672)
- IA-87-247, Final Response to FOIA Request for Documents.No Agency Records Subj to Request Have Been Located + (ML20213G673)
- ML20213G673 + (ML20213G673)
- ML20213G674 + (ML20213G674)
- ML20213G675 + (ML20213G675)
- ML20213G678 + (ML20213G678)
- ML20213G679 + (ML20213G679)
- ML20213G680 + (ML20213G680)
- 05000247/LER-1986-033, :on 861015,480 Volt Emergency Diesel Generator Output Breakers 52 Eg 2A & 52 Eg 2B Failed to Close During Surveillance Check Causing Required Plant Shutdown.Cause Unknown.Breaker Racked Back to Svc & Tested + (ML20213G682)
- ML20213G684 + (ML20213G684)
- IA-87-220, Package Consisting of Task 3,Scope of Work for Mitre Corp Contract NRC-85-060,Plant License Extension + (ML20213G686)
- ML20213G686 + (ML20213G686)
- ML20213G688 + (ML20213G688)
- ML20213G694 + (ML20213G694)
- ML20213G696 + (ML20213G696)
- ML20213G698 + (ML20213G698)
- ML20213G699 + (ML20213G699)
- ST-HL-AE-2164, Forwards Revised Proof & Review Tech Specs & Offsite Dose Calculation Manual Pages for Incorporation Into Final Proof & Review Tech Specs.Revised Tech Specs & Offsite Dose Calculation Manual Pages Based on Agreement W/Util + (ML20213G700)
- PNO-III-86-133, on 861113,NRC Issued Full Power Ol.Plant Startup Expected on 861116,following Maint & Mod Outage + (ML20213G701)
- ML20213G702 + (ML20213G702)
- ML20213G703 + (ML20213G703)
- ML20213G704 + (ML20213G704)
- ML20213G707 + (ML20213G707)
- ML20213G709 + (ML20213G709)
- ML20213G712 + (ML20213G712)
- ML20213G713 + (ML20213G713)
- IR 05000344/1986030 + (ML20213G714)
- ML20213G719 + (ML20213G719)
- ML20213G720 + (ML20213G720)
- ML20213G721 + (ML20213G721)
- ML20213G722 + (ML20213G722)
- 05000265/LER-1986-015-08, :on 861013,leakage from Containment Exceeded 75% of La Required by Tech Spec 3.7.A.2.b.Caused by Reduced Resiliency of Silicon Rubber Mfg by J-Bar Silicon Corp. Silicon Rubber Replaced + (ML20213G724)
- ML20213G725 + (ML20213G725)