- ML20212E156 + (ML20212E156)
- ML20212E158 + (ML20212E158)
- ML20212E164 + (ML20212E164)
- 05000249/LER-1986-024-05, :on 861205,unit Shutdown Commenced Due to Qualification Deficiency of Environmentally Qualified Cable Splices in Drywell Penetrations.Caused by Excessive Leakage Current.Qualified Tape Used to Repair Splices + (ML20212E165)
- ML20212E166 + (ML20212E166)
- ML20212E169 + (ML20212E169)
- ML20212E170 + (ML20212E170)
- ML20212E172 + (ML20212E172)
- ML20212E174 + (ML20212E174)
- TXX-6180, Final Deficiency Rept CP-86-17 Re Min Concrete Coverage of Reinforced Steel in Walls & Floors Required to Maintain 3 H Fire Rating.Initially Reported on 860321.Facility Design Complies W/Bldg Code.Item Not Reportable Per 10CFR50.55(e) + (ML20212E178)
- IR 05000344/1986040 + (ML20212E179)
- ML20212E181 + (ML20212E181)
- ML20212E182 + (ML20212E182)
- ML20212E185 + (ML20212E185)
- ML20212E186 + (ML20212E186)
- IA-97-379, Final Response to FOIA Request for Documents.No Agency Records Subject to Request Have Been Located + (ML20212E187)
- ML20212E187 + (ML20212E187)
- ML20212E188 + (ML20212E188)
- ML20212E189 + (ML20212E189)
- ML20212E191 + (ML20212E191)
- ML20212E194 + (ML20212E194)
- ML20212E195 + (ML20212E195)
- ML20212E197 + (ML20212E197)
- ML20212E200 + (ML20212E200)
- ML20212E201 + (ML20212E201)
- ML20212E203 + (ML20212E203)
- ML20212E208 + (ML20212E208)
- ML20212E210 + (ML20212E210)
- ML20212E211 + (ML20212E211)
- 05000456/LER-1987-008, :on 870129,reactor Tripped Due to Deenergization of Nuclear Instrumentation Sys as Protective Measure Against Water Intrusion Into Control Room.Caused by Plugged Drain.Drain Cleared & Flushed + (ML20212E215)
- ML20212E216 + (ML20212E216)
- 05000414/LER-1986-053-01, :on 861122,during Startup from 861120 Reactor Trip,Steam Generator Level Transient & Reactor Trip Occurred Due to Failure of Main Feedwater Pump Automatic Controller. Caused by Printed Circuit Card Failure + (ML20212E217)
- ML20212E221 + (ML20212E221)
- PNO-III-87-118B, AIT on-site Activities Concluded.Team Gathered Necessary Info to Evaluate Significance of Event by Interviewing Operators & Other Plant Personnel,Reviewing Records & by Observing Plant Conditions + (ML20212E222)
- ML20212E224 + (ML20212E224)
- PNO-III-87-103, on 870727,licensee Reduced Power to Approx 2% to Repair Feedwater Check Valve Which Was Leaking. Unusual Event Under Licensee Emergency Plan Was Declared,Due to Required Shutdown + (ML20212E225)
- ML20212E227 + (ML20212E227)
- IR 05000188/1986002 + (ML20212E228)
- ML20212E229 + (ML20212E229)
- PNO-III-87-097A, on 870714,preliminary Review of Incident Determined That Startup Transformer 1-2 Faulted.Cause of Initial Fault Still Under Investigation + (ML20212E230)
- ML20212E231 + (ML20212E231)
- ML20212E232 + (ML20212E232)
- PNO-II-87-079, on 871128,North Anna Unit 1 Was Taken Off Line Due to Excessive Seal Leakage on B Reactor Coolant Pump. Outage Planned for 10 Days to Replace Seal Package & Inspect Lower Radial Bearing on Pump.Commonwealth of VA Informed + (ML20212E233)
- ML20212E237 + (ML20212E237)
- ML20212E238 + (ML20212E238)
- PNO-III-87-086, on 870623,licensee Declared Alert When Smoke Was Discovered in Outside Containment Cable Penetration Area.Although Outside Assistance Was Not Required,Fire Dept Was Placed on Standby During Event + (ML20212E241)
- ML20212E243 + (ML20212E243)
- ML20212E244 + (ML20212E244)
- PNO-V-87-085, on 871231,Region V Ofc Notified by NRC Resident Ofc at Washington Public Power Supply Reactor Site That Tractor Trailer Vehicle Had Overturned on Steven Highway Outside Richland,Wa.State of Wa Notified + (ML20212E248)
- IR 05000298/1986027 + (ML20212E250)
- PNO-III-87-083A, on 870617,while Operating at 29% Power During Reactor Recirculation Test,Recirculation Pumps Tripped & Natural Circulation Established.Ait Being Sent to Site.Corrected Version of PNO-III-87-083 + (ML20212E251)