Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20206R692 + (ML20206R692)
- ML20206R693 + (ML20206R693)
- ML20206R694 + (ML20206R694)
- ML20206R696 + (ML20206R696)
- ST-HL-AE-1748, Forwards Response to NRC 850909 Request for Addl Info Re NUREG-0737,TMI Item II.E.4.2(6) Concerning Containment Purge & Vent Valve Operability.W/Four Oversize Drawing + (ML20206R697)
- ML20206R698 + (ML20206R698)
- ML20206R699 + (ML20206R699)
- PNO-III-98-008, on 980115,licensee Treated Patient to Prevent Restenosis of Coronary Artery for Addl 60 to 90 Seconds Due to Difficulty Returning Pellets to Storage Device.Cause Under Investigation + (ML20206R701)
- ML20206R702 + (ML20206R702)
- 05000423/LER-1987-012, :on 870320,Tech Spec Surveillance on Snubber Visual Insp Missed.Caused by Engineering Oversight & Outdated Snubber List.List Updated & All Snubbers Inspected + (ML20206R703)
- ML20206R705 + (ML20206R705)
- PNO-III-98-006, on 980115,licensee Announced Permanent Shut Down of Station.Util Plans to Maintain Plant in Safstor Decommissioning Mode Until Approx 2014 + (ML20206R706)
- ML20206R708 + (ML20206R708)
- PNO-III-98-005, on 980113,spring-loaded Shutter Off Mechanism on Radiography Device Failed Exposing Source When Radiographer Was in Area.Licensee Mannually Closed Shutter Mechanism & Secured Exposure Room + (ML20206R710)
- ML20206R711 + (ML20206R711)
- PNO-III-98-003, on 971217,male Patient Had I-125 Seeds Permanently Implanted in Prostate Gland with Prescribed Dose of 160 Gy.Of 88 Seeds Implanted Only 49 Seeds Were Actually retained,39 Seeds Ended Up in Bladder & Were Recovered + (ML20206R713)
- ML20206R714 + (ML20206R714)
- ML20206R716 + (ML20206R716)
- ML20206R717 + (ML20206R717)
- ML20206R718 + (ML20206R718)
- ST-HL-AE-2043, Forwards Revs to FSAR Tables 3.2.A-1 & 3.2.B-1 Re Quality Classification of Structures,Sys & Components.Revs Result of General Update for Consistency W/Project Design Documents & Include Editorial Changes + (ML20206R719)
- ML20206R721 + (ML20206R721)
- ML20206R722 + (ML20206R722)
- PNO-III-98-002, on 980105,util Announced Selection of PECO Energy Co to Provide Mgt Services for Station.Peco Energy Will Provide Six to Eight Managers to Fill Key Positions + (ML20206R723)
- ML20206R724 + (ML20206R724)
- ML20206R726 + (ML20206R726)
- ML20206R729 + (ML20206R729)
- ML20206R730 + (ML20206R730)
- 05000456/LER-1987-019, :on 870319,shiftly Check of Pressurizer Pressure Channels Not Performed.Caused by Procedural Error. Temporary Procedure Change 1194 Incorporated,Indicating That Pressurizer Pressure Channels Must Be Checked + (ML20206R731)
- ML20206R733 + (ML20206R733)
- ML20206R734 + (ML20206R734)
- BECO-86-139, Forwards Revs 4,5 & 6 to Emergency Plan,For Info.Rev 5 Complete Reissue of Plan + (ML20206R735)
- SNRC-1332, Responds to Generic Ltr 87-06, Periodic Verification of Leak Tight Integrity of Containment (App J) Pressure Isolation Valves (Pivs). Tech Spec 4.4.3.2.2 Requires Periodic Leak Testing of All PIVs + (ML20206R736)
- PNO-II-98-017, on 980320,female Contract Worker Found Unconscious at Bottom of man-lift Station in Turbine Bldg. Plant First Aid Team Responded & Ambulance Was Called. Injured Person Transported to Hosp & Pronounced Dead + (ML20206R737)
- IR 05000139/1986001 + (ML20206R738)
- ML20206R739 + (ML20206R739)
- PNO-I-98-025, on 980630,unit 3 Established Reactor Criticality,However Reactor Was Shut Down When Control Room Operator Noticed Spiking Intermediate Range Monitor.Licensee Troubleshooting + (ML20206R742)
- ML20206R744 + (ML20206R744)
- PNO-I-98-013, on 980417,alert Declared After Detection by Smell of Unidentified Odor,Initially Believed to Be Acetylene or Propane Gas,Resulting in Evacuation of Area. Fire Brigade Activated + (ML20206R745)
- ML20206R747 + (ML20206R747)
- ML20206R748 + (ML20206R748)
- ML20206R749 + (ML20206R749)
- 05000327/LER-1987-020, :on 840518,nonconformance Rept Written Describing Condition Where Class 1E Electrical Components Found Unprotected Against Potential Water Spray from Failure of Piping.Caused by Inadequate Design + (ML20206R751)
- ML20206R756 + (ML20206R756)
- ML20206R758 + (ML20206R758)
- 05000382/LER-1987-010, :on 870318,discovered That Retest of Pressurizer Surge Line PSL-203 Sample Header Inside Containment Isolation Valve Not Performed.Caused by Failure to Comply W/Mgt Controls & Procedures + (ML20206R759)
- ML20206R760 + (ML20206R760)
- ML20206R762 + (ML20206R762)
- ML20206R763 + (ML20206R763)
- PNO-I-98-002, on 980130,operators Declared Both Trains of Component Cooling Reactor & Reactor Plant River Water Sys Inoperable Due to Failure to Meet TS Surveillance Testing Requirements.Entered TS 3.0.3 & 4.0.3 + (ML20206R764)
- 05000312/LER-1987-021, :on 861121,pressurizer Heater Bundles Damaged Following Heater Breaker Trips.Caused by Energization of Heaters W/O Adequate Water Level & Inadequate Administrative Controls.Root Cause Investigation 86-34 Issued + (ML20206R765)