- 05000324/LER-1986-012-01, :on 860506,high Chlorine Alarm Condition Occurred.Caused by Failure to Close Chlorination Valve 2-CS-V34 Per Operating Procedures.Disciplinary Action Taken W/Personnel Involved + (ML20195D903)
- 05000341/LER-1998-006, :on 980905,failure of MSIVs to Meet Local Leak Rate Acceptance Criteria Was Noted.Caused by Minor Scale on Seat & Poppet,Linear Indications & Indentations in Nose Cone Area.Repaired & Retested Valves + (ML20195D910)
- ML20195D911 + (ML20195D911)
- ML20195D913 + (ML20195D913)
- ML20195D915 + (ML20195D915)
- ML20195D917 + (ML20195D917)
- ML20195D918 + (ML20195D918)
- ML20195D920 + (ML20195D920)
- ML20195D921 + (ML20195D921)
- ML20195D923 + (ML20195D923)
- ML20195D924 + (ML20195D924)
- ML20195D925 + (ML20195D925)
- 05000341/LER-1998-011, :on 981014,cracking in Silicone Fire Barrier Penetration Seal Occurred Due to High Temps.Caused by Inappropriate Translation of Vendor Matl Info Into Penetration Seal Design.With + (ML20195D926)
- IR 05000483/1988010 + (ML20195D928)
- ML20195D929 + (ML20195D929)
- ML20195D930 + (ML20195D930)
- IR 05000482/1988024 + (ML20195D933)
- ML20195D934 + (ML20195D934)
- ML20195D935 + (ML20195D935)
- ML20195D938 + (ML20195D938)
- ML20195D939 + (ML20195D939)
- CEO-88-319, Forwards Response to Violations Noted in Insp Rept 50-312/88-29.Response Withheld (Ref 10CFR2.790) + (ML20195D942)
- PNO-I-99-028, on 990608,Susquehanna Unit 2 Automatically Shut Down from 100% Power,Due to Failure in a Main Transformer. Region I Public Affairs Prepared to Respond to Media Inquires.Resident Inspectors on-site & Responded + (ML20195D943)
- ML20195D944 + (ML20195D944)
- ML20195D946 + (ML20195D946)
- ML20195D947 + (ML20195D947)
- ML20195D950 + (ML20195D950)
- ML20195D951 + (ML20195D951)
- ML20195D952 + (ML20195D952)
- ML20195D953 + (ML20195D953)
- 05000455/LER-1987-019-03, :on 871002,reactor Tripped Due to Turbine Trip from High Steam Generator Level.Caused by Equipment Operator Opening Sys Auxiliary Transformer Instead of Main Power Transformer Disconnects.Operator Disciplined + (ML20195D956)
- ML20195D958 + (ML20195D958)
- ML20195D961 + (ML20195D961)
- ML20195D962 + (ML20195D962)
- ML20195D965 + (ML20195D965)
- 05000301/LER-1986-002-01, :on 860430,control Operator Noticed That Analog RPI for Shutdown Bank B Misaligned.Shutdown Bank B Withdrawn.Cause Could Not Be Confirmed But Failure of Mechanical Demand Counter Suspected + (ML20195D966)
- PNO-II-99-023, on 990601,one CEA Descended Into Reactor Core for Unknown Reasons,With Unit 2 Rated Power.Licensee Noted Voltage Fluctuations on CEA Power Supplies.Licensee Is Continuing to Investigate CEA Problems + (ML20195D967)
- ML20195D971 + (ML20195D971)
- IR 05000072/1988001 + (ML20195D972)
- PNO-I-88-115, on 881101,reactor Scrammed from Full Power Due to Main Turbine Trip.Caused by Loss of Electrical Field on Main Generator.Reactor Stabilized in Shutdown Condition & Entered Into 5-day Outage,Including Deinerting of Drywell + (ML20195D975)
- ML20195D979 + (ML20195D979)
- ML20195D981 + (ML20195D981)
- ML20195D982 + (ML20195D982)
- L-98-212, Informs That Necessary Changes to Two Operating Surveillance Tests Can Not Be Completed by 981111.Necessitates Rev to Commitment to Develop New Surveillance Criteria by 981230 + (ML20195D985)
- ML20195D987 + (ML20195D987)
- ML20195D990 + (ML20195D990)
- ML20195D993 + (ML20195D993)
- IR 05000461/1988001 + (ML20195D994)
- ML20195D995 + (ML20195D995)
- B12945, Application for Amend to License NPF-49,decreasing Reactor Trip Setpoint & ESFAS Instrumentation Setpoint for Steam Generator Water Level Low Low Trip Setpoint from 23.5% to 20.73% of Narrow Range Instrument Span.Fee Paid + (ML20195D996)
- ML20195E003 + (ML20195E003)