Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20151G982 + (ML20151G982)
- ML20151G985 + (ML20151G985)
- ML20151G986 + (ML20151G986)
- ML20151G989 + (ML20151G989)
- ML20151G993 + (ML20151G993)
- ML20151G995 + (ML20151G995)
- IR 05000225/1988002 + (ML20151G997)
- 05000373/LER-1988-002-09, :on 880316,Type B & C Total Leakage Exceeded 0.6 La During Leak Rate Testing.Cause Undetermined.Valves Repaired as Necessary + (ML20151G998)
- ML20151H001 + (ML20151H001)
- ML20151H002 + (ML20151H002)
- ML20151H006 + (ML20151H006)
- ML20151H008 + (ML20151H008)
- ML20151H010 + (ML20151H010)
- ML20151H011 + (ML20151H011)
- ML20151H013 + (ML20151H013)
- ST-HL-AE-2714, Responds to NRC Re Violations Noted in Insp Rept 50-498/88-33.Corrective Action:Memo Issued on 880514 Stressing Responsibilities of Personnel Re Need for Detailed Planning & Understanding of Actions to Be Performed + (ML20151H014)
- ML20151H015 + (ML20151H015)
- 05000498/LER-1988-024, :on 880316,discovered That Resetting Safeguards Test Cabinet Master Reset Would Reset & Block Safety Injection Actuation on Train A,B or C.Caused by Design Error.Design Change Issued to Modify Circuitry + (ML20151H016)
- ML20151H017 + (ML20151H017)
- ML20151H018 + (ML20151H018)
- ML20151H019 + (ML20151H019)
- ML20151H020 + (ML20151H020)
- ML20151H022 + (ML20151H022)
- ML20151H023 + (ML20151H023)
- ML20151H027 + (ML20151H027)
- ML20151H028 + (ML20151H028)
- ML20151H032 + (ML20151H032)
- ML20151H034 + (ML20151H034)
- ML20151H037 + (ML20151H037)
- ML20151H039 + (ML20151H039)
- ML20151H043 + (ML20151H043)
- ML20151H044 + (ML20151H044)
- ML20151H047 + (ML20151H047)
- ML20151H050 + (ML20151H050)
- PNO-V-88-048, on 880717,unit Manually Tripped & Natural Cooldown Commenced as Result of Ground Fault in 12 Kv non- Vital Buses.Event Investigation Team Formed to Determine Location & Cause of Ground Fault + (ML20151H052)
- ML20151H054 + (ML20151H054)
- ML20151H055 + (ML20151H055)
- BSEP-88-0732, Advises That Corrective Actions for Unit 1 in Response to IE Bulletin 85-003 Complete,Per 880718 Telcons.Analysis to Support Plant Mods for Removal of Resistors Will Be Completed on 880719 for Unit 1 & on 880720 for Unit 2 + (ML20151H056)
- ML20151H059 + (ML20151H059)
- ML20151H064 + (ML20151H064)
- ML20151H066 + (ML20151H066)
- ML20151H068 + (ML20151H068)
- ML20151H071 + (ML20151H071)
- ML20151H075 + (ML20151H075)
- ML20151H077 + (ML20151H077)
- ML20151H078 + (ML20151H078)
- ML20151H080 + (ML20151H080)
- ML20151H083 + (ML20151H083)
- ML20151H085 + (ML20151H085)
- ML20151H087 + (ML20151H087)
- ML20151H088 + (ML20151H088)