Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20151G933 + (ML20151G933)
- ML20151G936 + (ML20151G936)
- ML20151G939 + (ML20151G939)
- ML20151G944 + (ML20151G944)
- PNO-II-88-043A, on 880715,augmented Insp Team Reviewed Events & Associated Corrective Actions for Equipment Failures.All Repairs Completed on 880716 Except Testing.Request for HPCI Limiting Condition for Operation Extension Granted + (ML20151G945)
- ML20151G948 + (ML20151G948)
- IR 05000336/1988006 + (ML20151G950)
- ML20151G952 + (ML20151G952)
- 05000338/LER-1988-013, :on 880319,turbine Trip/Reactor Trip Occurred. Caused by Electrohydraulic Fluid Control Sys Malfunction. Servo Control Valves for Four Governor Valves Replaced & Tested Satisfactorily + (ML20151G954)
- ML20151G956 + (ML20151G956)
- ML20151G961 + (ML20151G961)
- ML20151G965 + (ML20151G965)
- IR 05000334/1988015 + (ML20151G968)
- U-601164, Monthly Operating Rept for Mar 1988 + (ML20151G969)
- ML20151G973 + (ML20151G973)
- 05000498/LER-1987-026, :on 871212,discovered That Degraded Undervoltage Coincident W/Safety Injection Not Tested.Caused by Personnel Misinterpretation of Trip Actuation Devise Operational Test Requirements + (ML20151G975)
- ML20151G976 + (ML20151G976)
- ML20151G978 + (ML20151G978)
- ML20151G979 + (ML20151G979)
- ML20151G982 + (ML20151G982)
- ML20151G985 + (ML20151G985)
- ML20151G986 + (ML20151G986)
- ML20151G989 + (ML20151G989)
- ML20151G993 + (ML20151G993)
- ML20151G995 + (ML20151G995)
- IR 05000225/1988002 + (ML20151G997)
- 05000373/LER-1988-002-09, :on 880316,Type B & C Total Leakage Exceeded 0.6 La During Leak Rate Testing.Cause Undetermined.Valves Repaired as Necessary + (ML20151G998)
- ML20151H001 + (ML20151H001)
- ML20151H002 + (ML20151H002)
- ML20151H006 + (ML20151H006)
- ML20151H008 + (ML20151H008)
- ML20151H010 + (ML20151H010)
- ML20151H011 + (ML20151H011)
- ML20151H013 + (ML20151H013)
- ST-HL-AE-2714, Responds to NRC Re Violations Noted in Insp Rept 50-498/88-33.Corrective Action:Memo Issued on 880514 Stressing Responsibilities of Personnel Re Need for Detailed Planning & Understanding of Actions to Be Performed + (ML20151H014)
- ML20151H015 + (ML20151H015)
- 05000498/LER-1988-024, :on 880316,discovered That Resetting Safeguards Test Cabinet Master Reset Would Reset & Block Safety Injection Actuation on Train A,B or C.Caused by Design Error.Design Change Issued to Modify Circuitry + (ML20151H016)
- ML20151H017 + (ML20151H017)
- ML20151H018 + (ML20151H018)
- ML20151H019 + (ML20151H019)
- ML20151H020 + (ML20151H020)
- ML20151H022 + (ML20151H022)
- ML20151H023 + (ML20151H023)
- ML20151H027 + (ML20151H027)
- ML20151H028 + (ML20151H028)
- ML20151H032 + (ML20151H032)
- ML20151H034 + (ML20151H034)
- ML20151H037 + (ML20151H037)
- ML20151H039 + (ML20151H039)
- ML20151H043 + (ML20151H043)
- ML20151H044 + (ML20151H044)