Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20150C697 + (ML20150C697)
- 05000295/LER-1978-094, Forwards LER 78-094/03L-0 + (ML20150C698)
- PNO-III-88-021, on 880312,source Failed to Return to Shielded Position.Caused by Chip in Nylon Pinion Gear of Shutter Drive Mechanism.Defective Gear Replaced & Unit Functioned Properly + (ML20150C700)
- 05000295/LER-1978-094-03, /03L-0 on 780914:on a Phase a isolation,1FCV-PR24B & 1FCV-WD17A Failed to Close Placing Containment Isolation Sys in Degraded Mode.Caused by Asco 8320 Solenoid Valve Failing to Close Due to Oil in Instru Air + (ML20150C703)
- 05000295/LER-1978-091, Forwards LER 78-091/03L-0 + (ML20150C708)
- ML20150C709 + (ML20150C709)
- ML20150C711 + (ML20150C711)
- 05000295/LER-1978-091-03, /03L-0 on 780914: Damper Switching Sequence from Normal to Accident Mode Caused Pressure Differential in 1B Rcfc.Pressure Differential Caused Accident Inlet Damper Blades to Flex & Bend.Switching Sequence to Be Changed + (ML20150C712)
- ML20150C715 + (ML20150C715)
- ML20150C716 + (ML20150C716)
- ML20150C718 + (ML20150C718)
- 05000295/LER-1978-097, Forwards LER 78-097/03L-0 + (ML20150C722)
- ML20150C723 + (ML20150C723)
- ML20150C724 + (ML20150C724)
- ML20150C726 + (ML20150C726)
- 05000295/LER-1978-097-03, /03L-0 on 781004:Unit 1 Component Cooling Radiat Monitor Would Not Respond to Check Source.Caused by Water Damaged Detector in Detector Well & Defective Rate Board + (ML20150C728)
- IR 05000413/1988019 + (ML20150C729)
- ML20150C730 + (ML20150C730)
- ML20150C731 + (ML20150C731)
- 05000295/LER-1978-102, Forwards LER 78-102/03L-0 + (ML20150C732)
- W3P88-1234, Responds to Violations Noted in Insp Rept 50-382/88-08. Corrective Actions:Revised Work Instruction Implemented & Rev 5 to OP-2-009 Issued to Address Missing HVF-211A(B) Root Valve + (ML20150C733)
- ML20150C734 + (ML20150C734)
- 05000295/LER-1978-102-03, /03L-0 on 781006:Westinghouse Reported 0.5% Error in Apdms Limit Calculations Due to Roundoff & Addl Apparent Error Totaled 1.5%,creating Potential for Exceeding Apdms Limits.Caused by X.Xxx Format of Apdms Calculations + (ML20150C737)
- ML20150C739 + (ML20150C739)
- ML20150C740 + (ML20150C740)
- 05000295/LER-1978-096, Forwards LER 78-096/03L-0 + (ML20150C741)
- ML20150C742 + (ML20150C742)
- ML20150C743 + (ML20150C743)
- ML20150C744 + (ML20150C744)
- 05000295/LER-1978-096-03, /03L-0 on 780904:channel 1L-537 Higher than 2 Redundant Channels Due to Steam Leak on Root Valve (3/4, Manual,Globe)On Sensing Line Xmtr.Channel Failed Again on 780908.Root Valve Replaced + (ML20150C746)
- ML20150C748 + (ML20150C748)
- ML20150C749 + (ML20150C749)
- ML20150C750 + (ML20150C750)
- ML20150C751 + (ML20150C751)
- ML20150C756 + (ML20150C756)
- ML20150C757 + (ML20150C757)
- ML20150C758 + (ML20150C758)
- 05000278/LER-1988-005-02, :on 880613,RWCU Outboard Isolation Valve Logic Actuation Occurred on False Sys High Flow Signal.Caused by Equipment Failure.Insp & Rework of Class 1E Splices & Cables Performed.Isolation Reset + (ML20150C759)
- ML20150C760 + (ML20150C760)
- ML20150C761 + (ML20150C761)
- ML20150C762 + (ML20150C762)
- ML20150C764 + (ML20150C764)
- ML20150C765 + (ML20150C765)
- ML20150C766 + (ML20150C766)
- ML20150C767 + (ML20150C767)
- ML20150C769 + (ML20150C769)
- ML20150C770 + (ML20150C770)
- ML20150C771 + (ML20150C771)
- ML20150C772 + (ML20150C772)
- ML20150C773 + (ML20150C773)
- ML20150C774 + (ML20150C774)