ML20150C751

From kanterella
Jump to navigation Jump to search
Forwards Copy of Safety Analysis Rep:Use of UC2 Fissle Fuel Particles in Fort St Vrain Fuel Elements. Requests Review Be Completed by 790215
ML20150C751
Person / Time
Site: Fort Saint Vrain 
Issue date: 11/17/1978
From: Wessman G
GENERAL ATOMICS (FORMERLY GA TECHNOLOGIES, INC./GENER
To: Gammill W
Office of Nuclear Reactor Regulation
Shared Package
ML20150C754 List:
References
NUDOCS 7811240232
Download: ML20150C751 (2)


Text

C FCRM 366 U. S. NUCLE AR REGULATORY COMMISSION /

7 77)

LICENSEE EVENT REPORT CONTROL DLOCK:

l l

l l

l h

(PLEASE PRINT OR TYPE ALL REQUIRED INFORMATION) l0 l1 l l M l I l D l C l C l 2 l@l 0 { 0 l - l 0 l 0 l 0 l 0 l 0 l ~ 10 l 0 l@l 4 l 1 l 1 l 1 l 1 l@l l

l@

8 9 LICENSEE CODE 14 15 LICENSE NUMBER 25 26 LICENSE T YPE JO S7 C A T b8 CON'T l0l1I

'$"C,' l L j@l 0 l 5 l 0 { 0 l 0 l 3 l 1 l 6 j@l 1 l 0 l 1 l 917 l 8 l@l1 11 10 l3 l 7 18 l@

S 7

8 60 61 DOCKET NUMBER 68 69 EVENT OATE 74 7b REPORT DATE 80 EVENT DESCRIPTION AND PROBABLE CONSEQUENCES h lol2l l WHILE ATTEMPTING TO PROVE OPERABILITY OF 2AB EMERG. DIESEL IN ORDER TO REMOVE l

2CD DIESEL FROM SERVICE, THE ENGINE FAILED TO START.

THIS CONSTITUTED AN IN-l y g,3,

OPERABLE POWER SOURCE PER T.S. 3.8.1.1.

INVESTIGATION REVEALED APPARENT LACK l

,g,,,

l OF FUA TO THE INJECTOR PUMPS.

ENGINE WA ' GAIN TESTED AND DID START ON THE l

yg,3j ;

THIRD ATTEMPT.

FUEL FILTER ELEMENT WAS REMOVED AND INSPECTED.

CONDITION OF l

l016l l lgl7; l ELEMENT APPEARED SATISFACTORY, BUT A NEW ELEMENT WAS INSTALLED.

ENGINE WAS l

INOPERABLE FOR 27 MINUTES.

NO PROBABLE CONSEQUENCES.

l gyg sueC70E suTEE S$3M"

'^ "o E su'acFOSE S'

^S CO COueONENT COoE l0l9l l E l E l@ l E l@ l B l@ l El Nl Gl Il Nl El@ l Z l@ W @

7 F

9 10 11 12 13 18 19 20 S E QUE N TI AL OCCU R R E NCE REPORT REVISION REPORT NO.

CODE TYPE NO.

lVE NT YE AR l-l l 0 l 7l 9l l/l l013l lLl l-l l 0l 3 p no E

@ng 7l 8l

_ 21 27 23 24 26 21 28 2')

Ju 31 32 TAKEN CTION ON PL ANT T O HOURS S B IT D FOR BUB.

5 PPLIE MAN FACTUfER lA l@l ZlQ lZ l@

l Zl@

l 01 0l 0l 0l lNl@

l Y l@

l Ll@

l Wl 3 l 1 l 4 l@

33 34 3b 36 3/

40 di 42 43 44 47 CAUSE DESC71PTION AND CORRECTIVE ACTIONS li lo l l THE CAUSE FOR THE APPARENT LACK OF FUEL COULD NOT BE DETERMINED.

FOLLOW-I ING THE ACTION DESCRIBED IN ITEM 10 ABOVE, THE ENGINE STARTED SATISFACTO-l

,,,3j RILY AND HAS CONTINUED TO DO SO ON NUMEROUS OCCASSIONS SUBSEQUENT TO THE l

EVENT.

,,, l SINCE THIS IS THE FIRST OCCURRENCE OF THIS TYPE, NO FURTHER ACTION l

IS PLN4NED.

l 80 7

8 9 ST

, POWER O THER ST ATUS SC ' FY DISCOJE RY DESCRIPTION l > l 51 1l@ l O! 9l 0l@l NA l

l B l@l REDUNDANT EQUIPMENT OPERABILITY TESTl

'2

" Aa,v,Tv CO b nEteAsE Or RF'. east AMOUNT OF ACTIVITY LOC ATION OF RE LE ASE l1 l c l l Z l @c3 l Zl@l NA l

l NA l

1 H 9 10 11 44 45 80 PEH50NNEL EXPO 5URLS N UMB E R TYPE DE SCRIPTION l i l -l [ 0 l 0 l 0 l@l Z l@l N

bp l

I 7

8 9 11 12 13 80 Ur E SCR IP T I ON 11 IHj l0l0l0l@l NA l

1 11 9 11 12 80 TY E C PT )

I i I o I LzJ@l_

"A I

7 8 9 10 80 lMyr 3 E! C RipTION 12101 I N l@l NA l

llllllllll lllj 8 9 to r, H 69

80. E f>16-65-5901, EXT. 398 N AME OF PREPARER PHONE: