Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20149F003 + (ML20149F003)
- ML20149F004 + (ML20149F004)
- ML20149F007 + (ML20149F007)
- ML20149F011 + (ML20149F011)
- ML20149F012 + (ML20149F012)
- ML20149F016 + (ML20149F016)
- ML20149F017 + (ML20149F017)
- ML20149F018 + (ML20149F018)
- ML20149F021 + (ML20149F021)
- ML20149F022 + (ML20149F022)
- 05000341/LER-1987-055, :on 871210,isolation of RCIC Sys Steam Line Occurred.Caused by Inadequacy in Sys Operating Procedure.Rev Made to Operating Procedure Which Directs Operator to Throttle Inboard & Outboard Isolation Valves + (ML20149F023)
- ML20149F025 + (ML20149F025)
- LD-88-001, Corrects Record Re Info Previously Provided in Re post-accident Uncertainties Associated W/Core Exit Thermocouple Sys Supplied by C-E.NRC Should Disregard Inclusion of Plant in Previous Info Package + (ML20149F026)
- 05000483/LER-1988-002, :on 880107,two RHR Trains Rendered Inoperable When Operator Inadvertently Closed cross-connect Valve. Caused by Control Switches Being in Close Proximity to Each Other.Control Switches Covered W/Plastic + (ML20149F028)
- IR 05000373/1997008 + (ML20149F029)
- 05000413/LER-1987-043, :on 871105,RCS Monitoring Instrumentation Declared Inoperable.Caused by Design Deficiency.Unit 1 Resistance Temp Detector Junction Boxes Sealed by Filling Epoxy.Unit 2 Boxes Will Be Sealed or Replaced + (ML20149F030)
- ML20149F032 + (ML20149F032)
- ML20149F033 + (ML20149F033)
- 05000374/LER-1987-016-01, :on 870713,min Flow Switch Found to Be Leaking Water Through Switch Internals During Performance of Instrument Surveillance.Cause Undetermined.Defective Switch Replaced,Calibr & Returned to Svc + (ML20149F035)
- ML20149F036 + (ML20149F036)
- ML20149F037 + (ML20149F037)
- 05000370/LER-1987-021-02, :on 871130,reactor Trip Occurred.Caused by Reversed Wiring on Generator Stator Cooling Differential Pressure (D/P) Switch Circuitry Combined W/Calibr Drift of D/P Switch & Gauge.Wiring Will Be Corrected + (ML20149F039)
- ML20149F041 + (ML20149F041)
- ML20149F043 + (ML20149F043)
- ST-HL-AE-2493, Forwards Radial Peaking Factor Limit Rept Per Tech Specs 4.2.2.2e & 6.9.1.6 + (ML20149F044)
- ML20149F047 + (ML20149F047)
- ML20149F048 + (ML20149F048)
- ML20149F051 + (ML20149F051)
- NL-88-113, Forwards Updated NRC Open Item Closure Schedule & Summary Status.Weekly Updates Will Be Provided Until Restart + (ML20149F055)
- ML20149F056 + (ML20149F056)
- ML20149F060 + (ML20149F060)
- ML20149F062 + (ML20149F062)
- ML20149F064 + (ML20149F064)
- ML20149F066 + (ML20149F066)
- ML20149F068 + (ML20149F068)
- 05000364/LER-1987-010-01, :on 871209,unit Shutdown Due to Pressure Boundary Leakage on RCS Loop B Cold Safety Injection Line Between Check Valve & Loop.Caused by Cracked Joint Due to Fatigue.Defective Pipe Section Replaced + (ML20149F069)
- ML20149F071 + (ML20149F071)
- ML20149F072 + (ML20149F072)
- ML20149F073 + (ML20149F073)
- ML20149F075 + (ML20149F075)
- ML20149F077 + (ML20149F077)
- ML20149F078 + (ML20149F078)
- ML20149F081 + (ML20149F081)
- ML20149F083 + (ML20149F083)
- ML20149F084 + (ML20149F084)
- ML20149F085 + (ML20149F085)
- ML20149F087 + (ML20149F087)
- AECM-88-0002, Documents 871029 Telcon Re Standby Svc Water Solutions & Advises of Insp Completion of Div I & II Emergency Diesel Generator Jacket Water Hxs,Rhr C Pump Room Cooler & Other Components,Per Insp Rept 50-416/87-03 + (ML20149F088)
- ML20149F089 + (ML20149F089)
- NSD-NRC-97-5231, Forwards Formal Transmittal of Correspondence Previously Sent Over Period 970515-970605.W/index + (ML20149F091)
- ML20149F092 + (ML20149F092)