- ML20133M243 + (ML20133M243)
- ML20133M244 + (ML20133M244)
- 05000336/LER-1996-041-02, :on 961217,invalid Local Lrt of Fuel Transfer Tube Flange Discovered Due to Blockage of Test Port W/ Silicon Rubber Sealant Compound & Lack of Procedural Guidance.Developed Procedure + (ML20133M246)
- ML20133M247 + (ML20133M247)
- ML20133M250 + (ML20133M250)
- ML20133M253 + (ML20133M253)
- ML20133M256 + (ML20133M256)
- ML20133M257 + (ML20133M257)
- ML20133M258 + (ML20133M258)
- ML20133M261 + (ML20133M261)
- ML20133M262 + (ML20133M262)
- ML20133M263 + (ML20133M263)
- ML20133M264 + (ML20133M264)
- ML20133M266 + (ML20133M266)
- ML20133M267 + (ML20133M267)
- ML20133M270 + (ML20133M270)
- ML20133M272 + (ML20133M272)
- ML20133M274 + (ML20133M274)
- ML20133M275 + (ML20133M275)
- ML20133M278 + (ML20133M278)
- U-600197, Renews 841025 Request for Termination of Overinsp Program for Electrical Hangers (Cable Tray Hangers & Conduit Supports).Technical Justification for Request & Responses to 850411 Questions Encl + (ML20133M281)
- ML20133M283 + (ML20133M283)
- ML20133M286 + (ML20133M286)
- ML20133M289 + (ML20133M289)
- 05000315/LER-1985-030, :on 850705,10 Inoperable Radioactive Gaseous Process & Effluent Monitoring Instrumentation Channels Discovered During Procedural Review.Caused by Failure to Test.Tech Specs Implemented Immediately + (ML20133M291)
- ML20133M292 + (ML20133M292)
- ML20133M293 + (ML20133M293)
- 05000213/LER-1985-025, :on 850919,unplanned Release of Radwaste to Environ Detected.Caused by Isolation Valve Left Open Through Operator Error & Ambiguous Valve Tag Numbers.Event Reviewed W/Operators & Valves Relabeled Clearly + (ML20133M294)
- ML20133M296 + (ML20133M296)
- ML20133M297 + (ML20133M297)
- ML20133M299 + (ML20133M299)
- ML20133M301 + (ML20133M301)
- ML20133M303 + (ML20133M303)
- ML20133M304 + (ML20133M304)
- IA-85-342, Further Response to FOIA Request for Records Re CE Norelius & JW Cook 850322 Ltr Concerning BNL 850110 Rept Re Allegation of Ee Kent.App B Documents Completely Withheld (Ref FOIA Exemption 7).Search Continuing + (ML20133M304)
- 05000237/LER-1985-030-03, :on 850716,high Radiation Signal from Refueling Floor Radiation Monitors Caused Reactor Bldg Ventilation Sys Trip.Caused by Fuel Handlers Lifting Machinery for Repairs.Machine Submerged + (ML20133M307)
- 05000309/LER-1985-011, :on 850916,ECCS Partially Activated.Caused by Accidental Displacement of Safety Injection Signal Blocking Devices.Addl Devices Installed to Prevent Subsequent Activation + (ML20133M310)
- ML20133M311 + (ML20133M311)
- ML20133M315 + (ML20133M315)
- ML20133M317 + (ML20133M317)
- IR 05000424/1985032 + (ML20133M318)
- 05000244/LER-1985-017, :on 850916,rod Control Sys on Bank D Switch Allowed Only Two Rods in Each of Banks B & D to Move, Causing Control Rod Insertion & Bank Overlap Violations. Caused by Faulty Firing Card.Card Replaced + (ML20133M320)
- ML20133M322 + (ML20133M322)
- ML20133M325 + (ML20133M325)
- ML20133M326 + (ML20133M326)
- ML20133M330 + (ML20133M330)
- IA-85-435, Responds to FOIA Request for Communication W/Nrc Re Ownership of Psychiatric Diagnostic Labs of America,Inc.App Documents Available in PDR + (ML20133M330)