- 05000354/LER-1991-010, :on 910515,discovered ESF Actuation & Automatic Closure of RCIC Torus Vaccum Breaker Inboard Isolation Valve During Functional Testing.Cause Not Determined.Procedure Revised + (ML20116N192)
- LD-85-022, Responds to 841126 Request for Addl Info Re Modified Acceptance Criteria for CESSAR-F Section 14.2.12.5.17 on Main & Emergency Feedwater Sys Test.Listed Criterion Will Be Added to Future Amend + (ML20116N196)
- 05000302/LER-1992-015, :on 920717,EFIC Sys Actuation Occurred Due to Low OTSG Level.Plant Startup Procedure Will Be Revised to Assure That Both Main Feedwater Pumps Are Capable of Controlling Main Feedwater Flow + (ML20116N197)
- ML20116N198 + (ML20116N198)
- 05000302/LER-1992-022, :on 921015,discovered That RCP Lube Oil Collection Drain Tanks Exhibited Fluid Level of 19%.Caused by Accumulation of Over 65 Gallons of Water in Tanks.Fluid Drained from Lube Oil Collection Drain Tanks + (ML20116N199)
- 05000331/LER-1992-016, :on 921022,control Bldg Chiller B Tripped & Could Not Be Promptly Restarted,Resulting in Loss of Control Bldg Air Conditioning.Caused by Air Bubble in Chilled Water Piping.Air Purged & Circuitry Verified Intact + (ML20116N201)
- ML20116N209 + (ML20116N209)
- RBG-43157, Monthly Operating Rept for Jul 1996 for River Bend Station Unit 1 + (ML20116N215)
- RC-96-0203, Forwards semi-annual fitness-for-duty Report for 960101-0630 + (ML20116N217)
- ML20116N225 + (ML20116N225)
- ML20116N231 + (ML20116N231)
- ML20116N232 + (ML20116N232)
- ML20116N238 + (ML20116N238)
- 05000416/LER-1992-019, :on 921104,UFSAR for Facility Does Not Correctly Reflect Iodine Dose Conversion Factors Employed in Design Basis Loca.Caused by Inadequate Documentation of Design Basis Assumptions.Ufsar Updated + (ML20116N240)
- ML20116N241 + (ML20116N241)
- 05000341/LER-1992-011, :on 921024,reactor Pressure Vessel Low Level Trips Occurred During Vessel Pressure Test.Caused by Bumpimg Instrument Rack.Barrier Will Be Installed Around Instrument Rack H21-P004 + (ML20116N245)
- ML20116N249 + (ML20116N249)
- 3F0896-16, Submits Results of Refuel 10 Augmented Insp of Pressurizer Nozzle to Lower Head Weld Indication Detected During Refuel 9 + (ML20116N258)
- ML20116N261 + (ML20116N261)
- ML20116N266 + (ML20116N266)
- ML20116N267 + (ML20116N267)
- ML20116N268 + (ML20116N268)
- ML20116N272 + (ML20116N272)
- ML20116N273 + (ML20116N273)
- ML20116N274 + (ML20116N274)
- ML20116N277 + (ML20116N277)
- ML20116N288 + (ML20116N288)
- 05000341/LER-1992-009, :on 921021,Wyle Labs Notified Util That Nine SRVs Exceeded TS Acceptance TS Tolerance of Plus or Minus 1% of Pressure Setpoint.Caused by Pilot disc-to-seat Sticking.Srv Pilot Assemblies Replaced + (ML20116N291)
- ML20116N292 + (ML20116N292)
- ML20116N294 + (ML20116N294)
- ML20116N298 + (ML20116N298)
- 05000325/LER-1992-008-03, :on 921019,identified Leakage of Piping Off of Nuclear Header to Dg.Caused by Degraded Pipe Lining Which Resulted in Failure.Permanent Code Repair to Pipe Through Wall Leak on Line 2-SW-29-18-157 Completed + (ML20116N302)
- ML20116N303 + (ML20116N303)
- 05000445/LER-1992-025, :on 921023,equipment Failure Resulted in Drop of Four Control Bank B Group 1 Control Rods & Manual Reactor Trip.Caused by Inadequate Interior Cooling of Affected Rod Control Cabinet + (ML20116N306)
- ML20116N312 + (ML20116N312)
- ML20116N314 + (ML20116N314)
- ML20116N316 + (ML20116N316)
- ML20116N318 + (ML20116N318)
- ML20116N319 + (ML20116N319)
- ML20116N327 + (ML20116N327)
- ML20116N331 + (ML20116N331)
- ML20116N337 + (ML20116N337)
- ML20116N347 + (ML20116N347)
- ML20116N352 + (ML20116N352)
- ML20116N357 + (ML20116N357)
- 05000277/LER-1992-023, :on 921028,hourly Firewatches for Emergency Switchgear & Motor Generator Rooms Not Performed Per TS Due to Personnel Error.Training Will Be Conducted Re Aspects of Firewatch Insps + (ML20116N358)
- ML20116N360 + (ML20116N360)
- ML20116N361 + (ML20116N361)
- ML20116N368 + (ML20116N368)
- ML20116N369 + (ML20116N369)
- B11521, Forwards Tornado Missile Risk Analysis of Millstone Unit 3 Emergency Generator Encl Openings, Final Summary Rept for Mar 1985,in Support of Resolution of SER Open Item 2. Encl Rept Satisfies Option 2 of 841210 Sser + (ML20116N372)