Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20107H889 + (ML20107H889)
- ML20107H891 + (ML20107H891)
- ML20107H896 + (ML20107H896)
- ML20107H907 + (ML20107H907)
- ML20107H909 + (ML20107H909)
- ML20107H914 + (ML20107H914)
- ML20107H915 + (ML20107H915)
- ML20107H916 + (ML20107H916)
- ML20107H917 + (ML20107H917)
- 05000352/LER-1984-013-03, :on 850117,HPCI Sys Steam Supply Pressure Instrument PT-55-1N058F Removed from Svc for Troubleshooting & Not Placed in Tripped Condition.Caused by Personnel Error. Requirements Clarified + (ML20107H920)
- ML20107H925 + (ML20107H925)
- ML20107H932 + (ML20107H932)
- ML20107H937 + (ML20107H937)
- ML20107H939 + (ML20107H939)
- ML20107H945 + (ML20107H945)
- ML20107H946 + (ML20107H946)
- BECO-84-187, Forwards Util Commitments to Reg Guide 1.97,Generic Ltr 82-33 Re Description of Acceptable Method to Provide Instrumentation to Monitor Plant Variables & Safety Parameter Display Sys During & Following Accidents + (ML20107H947)
- ML20107H948 + (ML20107H948)
- W3P85-0364, NPDES Noncompliance Notification:On 850130,BOD5 Concentration & Oil & Grease Concentration Levels Exceeded Permit Limits.Caused by Cold Weather Slowing Process in Sewage Plant & Trapped Moisture in Oil + (ML20107H950)
- B06004, Approves of Fes for Facility.Epa Concerns Addressed in Re Des Resolved + (ML20107H952)
- ML20107H956 + (ML20107H956)
- ML20107H961 + (ML20107H961)
- 05000336/LER-1985-001, :on 850123,safety Analysis Error Found.Caused by Inconsistency Between Tech Spec Requirement on Axial Shape Index & Safety Analysis Assumptions on Index Used as Input to Small Break LOCA Analysis + (ML20107H963)
- ML20107H964 + (ML20107H964)
- ML20107H971 + (ML20107H971)
- ML20107H972 + (ML20107H972)
- ML20107H977 + (ML20107H977)
- ML20107H978 + (ML20107H978)
- ML20107H980 + (ML20107H980)
- ML20107H989 + (ML20107H989)
- 05000247/LER-1985-001, :on 850202 Reactor Manually Tripped.Caused by H Leak & Oil Mist from Main Generator Shaft Seals Due to Malfunction of Oil Filter in Seal Oil Supply Line.Filter Repaired Correcting H Leak + (ML20107H991)
- ML20107H998 + (ML20107H998)
- ML20107J000 + (ML20107J000)
- 05000454/LER-1985-016, :on 850124,reactor Trip Occurred.Caused by Instrument Mechanic Grounding Strip Chart Recorder Connector Using Incorrect Size for Connectors.Surveillances Performed to Verify Proper Operation of Trains + (ML20107J006)
- ML20107J007 + (ML20107J007)
- ML20107J009 + (ML20107J009)
- B11450, Forwards Summary of Core Barrel Insp Planned During 1985 End of Cycle 6 Refueling Outage.Insp Results & Conclusions Will Be Provided by 850601 + (ML20107J013)
- ML20107J014 + (ML20107J014)
- 05000454/LER-1985-017, :on 850119,PORV Block Valves Not Deenergized During RCS Leak Test.Caused by Misinterpretation of Tech Spec Limiting Condition for Operation.Personnel Briefed + (ML20107J016)
- ML20107J025 + (ML20107J025)
- FVY-84-128, Forwards Results of Detailed Engineering Evaluation of Potential Oxygen Addition to Primary Containment Conducted to Satisfy Criteria of Generic Ltr 84-09.Hydrogen Recombiner Capability Not Necessary + (ML20107J027)
- ML20107J050 + (ML20107J050)
- ML20107J053 + (ML20107J053)
- IR 05000219/1974005 + (ML20107J055)
- W3P85-0464, Forwards Program to Perform Confirmatory Analyses,Nuclear Plant Island Structure Basemat, Concerning Cracking of Basemat.Program Plan Incorporates NRC Comments from 850213 Meeting + (ML20107J073)
- TXX-9611, Forwards Rev 1 to Interim Change Request ISI-2, CPSES Unit 2 ASME Section XI ISI Program Plan + (ML20107J078)
- 05000321/LER-1984-016-01, :on 840929,reactor Protection Sys Logic Actuation Occurred from Erratic Reactor Water Level a Instruments 1B21-N017A & B.Caused by Air Trapped in Instrument Lines.Variable Leg Backfilled + (ML20107J079)
- 05000395/LER-1984-041, :on 840928,reactor Tripped from Approx 10% Power & Intermediate Range High Flux Bistable Did Not Reset on Decreasing Power.Caused by Operator Error.Incident Reviewed W/Personnel + (ML20107J087)
- ML20107J088 + (ML20107J088)
- ML20107J091 + (ML20107J091)
- ML20107J093 + (ML20107J093)