- 05000412/LER-1996-001, :on 960212,PSC Rod Bank Pulse Step Counter Positions Indicating 0 Steps.Caused by Electrical Distribution Sys Disturbance That Occurred 36 H Earlier. Performed Manual Cold Start of PCS + (ML20101D314)
- ML20101D316 + (ML20101D316)
- ML20101D317 + (ML20101D317)
- ML20101D320 + (ML20101D320)
- BSEP-96-0072, Submits Suppl Response to NRC GL 94-02, Long-Term Solutions & Upgrade of Interim Operating Recommendations for Thermal- Hydraulic Instabilities in Bwrs + (ML20101D322)
- B11394, Forwards marked-up Draft STS for Four Loop Operation of Plant.Draft STS for Three Loop Operation Forthcoming. Requests Meeting Be Arranged W/Nrc for Early Jan 1985 to Discuss Review Process & Future Draft Submittals + (ML20101D324)
- ML20101D326 + (ML20101D326)
- ML20101D332 + (ML20101D332)
- ML20101D335 + (ML20101D335)
- NSD-NRC-96-4666, Forwards Rept on Impact of Fan Cooler Operation on AP600 Aerosol Removal Rates & post-LOCA Aerosol Releases from Containment,In Support of RAI 470.25.Response to RAI 470.25 Scheduled for Completion by 960329 + (ML20101D339)
- ML20101D355 + (ML20101D355)
- NLS8400290, Responds to 841026 Request for Plans & Proposed Schedules to Implement Improvements in Water Level Measurement & Instrumentation Sys to Improve Reliability & Accuracy,Per Generic Ltr 84-23.Analog Equipment Will Be Installed + (ML20101D357)
- ML20101D375 + (ML20101D375)
- ML20101D376 + (ML20101D376)
- ULNRC-03346, Transmits Relief Requests R-1a,E-3a,E-4a,E-6 & E-7 to ISI Program Plan.Relief Requests Submitted Based on Insp Results from Refuel 7 & Represent Final Relief Requests for First ten-yr Insp Interval + (ML20101D393)
- ML20101D396 + (ML20101D396)
- ML20101D401 + (ML20101D401)
- 05000354/LER-1996-001, :on 960113,safety & Turbine Acs Heat Exchangers Fouled W/Detritus Occurred Due to Failed Svc Water Strainer. Strainers Replaced & Enhanced Maint & Design Mod + (ML20101D402)
- ML20101D406 + (ML20101D406)
- ML20101D408 + (ML20101D408)
- AECM-84-0528, Forwards Amend 2 to Indemnity Agreement B-72.Amend Deletes Item 3 & Substitutes Listed Licenses + (ML20101D409)
- RC-96-0072, Forwards Summaries & Conclusions for Evaluations Performed on SFP Cooling Subsys to Support Acceptability of SFP Peak Temps + (ML20101D413)
- ML20101D415 + (ML20101D415)
- ML20101D417 + (ML20101D417)
- 05000354/LER-1995-038-02, Forwards LER-95-038-02 Re Failure to Comply W/Required Action Statement Upon Removal of Failed Snubber on RHR Shutdown Cooling Line.Suppl Updates Corrective Actions + (ML20101D419)
- ML20101D420 + (ML20101D420)
- 05000354/LER-1995-038, :on 951127,failed to Comply W/Required Action Statement Upon Removal of Failed Snubber on RHR SDC Line.C/A to Avoid Unnecessary SDC Isolations & Associated Potential for Water Hammer Events Identified & Assigned in CAP + (ML20101D424)
- BSEP-96-0097, Monthly Operating Repts for Feb 1996 for BSEP + (ML20101D431)
- 05000458/LER-1996-009, :on 960214,DG Overspeed Tripped.Caused by Field Flash Relay Failure.Component Replaced & in-depth Evaluation Performed on Effects of Max Temp in Cabinet + (ML20101D441)
- 05000361/LER-1984-069, :on 841109,containment Purge Isolation Sys Actuation Occurred.Caused by Radwaste Being Moved in Vicinity of Monitor.Actions to Prevent Radioactive Items from Being Placed in Vicinity of Monitors + (ML20101D442)
- ML20101D443 + (ML20101D443)
- ML20101D453 + (ML20101D453)
- 05000374/LER-1984-075-01, :on 841112,reactor Protection Sys Bus Tripped. Caused by Grounded Lead on Frequency Meter Due to Meter Connected Backwards.Use of Ac or Dc Frequency Meter Will Be Incorporated Into Electrical Maint Training + (ML20101D474)
- ML20101D546 + (ML20101D546)
- ML20101D549 + (ML20101D549)
- ML20101D579 + (ML20101D579)
- ML20101D627 + (ML20101D627)
- 05000334/LER-1984-014, :on 841101,common Reservoir to Eight Lower Snubbers Found Out of Oil.Possibly Caused by O-ring Damage Leading to Leaking Fitting.Snubbers Purged of Air & Vacuum Filled W/Oil + (ML20101D649)
- 05000336/LER-1996-006-01, :on 960207,service Water Pump Motor Flood Protection Not Provided.Caused by Inadequate Administrative Controls.Administrative Controls Established + (ML20101D655)
- 05000352/LER-1984-007-02, :on 841114,core Spray Pump C,Rhr Pump C & Diesel Generator D13 Automatically Started.Caused by Improper Venting of Reactor Level Instrument Rack.Low Signal Cleared & Sys Returned to Operation + (ML20101D675)
- 05000334/LER-1984-013, :on 841024,cooling Water Pump Declared Inoperable.Caused by Flow Instrument Out of Calibr.Test Procedure Modified to Meet ASME Requirements + (ML20101D681)
- 05000413/LER-1984-022, :on 841115,emergency Core Cooling Flowpath Inoperable.Caused by Personnel Error.Locks Installed on Containment Sump Intake Screen Doors.Key to Locks Will Be Administratively Controlled + (ML20101D689)
- 05000374/LER-1984-073-01, :on 841112,reactor Water Cleanup Sys (Rwcs) Isolated on High Differential Temp in Pump Rooms.Caused by Lack of Circulating Air.Ge Investigating Differential Flow Setpoint + (ML20101D692)
- 05000352/LER-1984-021, :on 841115,fuse Blew,Causing Isolation of Reactor Water Cleanup Sys.Caused by Inboard Isolation Logic Relay Fuse Burnout from Electrical Short in Visicorder Test Cable Plug.Fuse Replaced & Sys Restored + (ML20101D695)
- ML20101D697 + (ML20101D697)
- 05000265/LER-1984-011-07, :on 841130,reactor Bldg Fuel Pool Channel B Area Radiation Monitor Tripped,Isolating Reactor Bldg Ventilation & Starting Standby Gas Treatment Sys.Cause Undetermined.No Corrective Action Necessary + (ML20101D706)
- ML20101D710 + (ML20101D710)
- ML20101D716 + (ML20101D716)
- 05000352/LER-1984-008-02, :on 841115,main Control Room Chlorine Analyzer Failed.Caused by Equipment Malfunction & Sample Tape Breaking,Causing Indicator to React full-scale.Broken Tape Replaced & Analyzer Recalibr + (ML20101D729)
- 05000440/LER-1996-002, :on 960218,partial Actuation of HPCS Sys Occurred.Caused by Inverter Circuitry Failure.Inverter Refurbished W/Replacement Electrolytic Capacitors,Bench Tested & Returned to Svc + (ML20101D730)
- ML20101D738 + (ML20101D738)