Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20100R436 + (ML20100R436)
- ML20100R440 + (ML20100R440)
- 05000373/LER-1996-001-06, :on 960213,missed TS Required Fire Protection Valve Position Verification Occurred.Caused by Human Performance.Operating Dept Senior Mgt Reinforced Expectations W/Sros & Shift Supervisors + (ML20100R441)
- ML20100R443 + (ML20100R443)
- ML20100R451 + (ML20100R451)
- ML20100R460 + (ML20100R460)
- ML20100R464 + (ML20100R464)
- B15508, Application for Amend to License NPF-49 Re Existing SRs 4.8.1.1.2.a.6 & 4.8.1.1.2.b to Require That DG Be Loaded to Greater than or Equal to 4986 Kw for at Least Sixty Minutes During Routine Surveillance + (ML20100R465)
- RBG-19462, Corrected Interim Deficiency Rept DR-252 Re Trunnion Welds on Pipe Support Components Supplied by Bf Shaw Co.Next Rept Will Be Submitted by 850124 + (ML20100R470)
- W3P84-3144, Final Deficiency Rept 179 Re Welding Maint & QA Program. Administrative Procedures Revised.Condition Not Reportable Per 10CFR50.55(e) + (ML20100R473)
- RBG-19463, Interim Deficiency Rept DR-251 Re Pipe Stress Analysis for Penetration mid-guard Restraints.Next Rept Will Be Provided by 850124 + (ML20100R474)
- ML20100R479 + (ML20100R479)
- ML20100R480 + (ML20100R480)
- RBG-19560, Interim Deficiency Rept DR-75 Re Ghosh-Wilson Computer Program Used in Reactor Bldg Hydrodynamic Analysis.Next Rept Will Be Provided by 850415 + (ML20100R481)
- ML20100R482 + (ML20100R482)
- RBG-19554, Interim Deficiency Rept DR-156 Re Conductivity Cells & Indicators Supplied by Ge.Next Rept Will Be Provided by 850131 + (ML20100R483)
- BECO-92-040, Boston Edison Co 1991 Annual Rept, W/Securities & Exchange Commission Form 10-K & + (ML20100R485)
- ML20100R486 + (ML20100R486)
- ML20100R492 + (ML20100R492)
- 05000352/LER-1996-003, :on 960204,ESFA Occurred Due to Loss of Power to Rps/Ups Power Distribution Panel Caused by Spurious Actuation of Underfrequency Relay.Replaced Relay + (ML20100R493)
- ML20100R504 + (ML20100R504)
- ML20100R505 + (ML20100R505)
- ML20100R508 + (ML20100R508)
- ML20100R510 + (ML20100R510)
- ML20100R513 + (ML20100R513)
- RBG-19590, Final Deficiency Rept DR-126 Re Discrepancies Between as-built Wiring & Diagrams of Class 1E 480-volt Load Ctrs Supplied by Powell Electric.No Performance Deviation Existed.Condition Not Reportable Per 10CFR50.55(e) + (ML20100R532)
- JPN-92-018, Forwards Info Re Use of Low Pressure Sys to Achieve & Maintain Safe Shutdown Following Control Room Fire,Per Concerns Raised During Recent NRC Fire Protection Insp + (ML20100R534)
- 05000414/LER-1996-001-02, :on 960206,loss of Offsite Power Due to Electrical Component Failures Occurred.Caused by Application of Type of Resistor Bushing Used.All Resister Bushing in Application Replaced + (ML20100R540)
- ML20100R541 + (ML20100R541)
- ML20100R543 + (ML20100R543)
- ML20100R552 + (ML20100R552)
- ML20100R578 + (ML20100R578)
- ML20100R610 + (ML20100R610)
- ML20100R634 + (ML20100R634)
- ML20100R636 + (ML20100R636)
- 05000443/LER-1996-002, :on 960207,inadequate SG Wide Range Water Level Channel Calibrations Occurred.Caused by Lack of Design Engineering Involvement in Original Surveillance Procedure Development.Procedures Will Be Revised + (ML20100R638)
- ML20100R648 + (ML20100R648)
- ML20100R653 + (ML20100R653)
- ML20100R655 + (ML20100R655)
- ML20100R659 + (ML20100R659)
- ML20100R661 + (ML20100R661)
- ML20100R666 + (ML20100R666)
- ML20100R671 + (ML20100R671)
- ML20100R689 + (ML20100R689)
- ML20100R690 + (ML20100R690)
- ML20100R701 + (ML20100R701)
- ML20100R712 + (ML20100R712)
- ML20100R713 + (ML20100R713)
- ML20100R714 + (ML20100R714)
- ML20100R723 + (ML20100R723)
- 05000498/LER-1989-017, Informs NRC of Change to Commitment Made as Result of LER 89-017 Re Event Involving Inadvertent Contamination of Nonradioactive Sys on 890814.Mods 89228,89229,89239 & 89231 No Longer Necessary.Justification Included + (ML20100R733)