- ML20100A426 + (ML20100A426)
- 05000387/LER-1985-005-01, :on 850213,verification of 6 Plus or Minus 1 Simulated Thermal Power Time Constant Inadvertently Omitted from Routine Surveillance Testing for Aprms.Time Constant Since Verified + (ML20100A429)
- ML20100A431 + (ML20100A431)
- 05000388/LER-1985-009, :on 850212,setpoints for Three Reactor Water Level Switches Found to Be Outside Acceptance Criteria During Performance of Scheduled Surveillance.Caused by Instrument Drift.Instruments Recalibr + (ML20100A432)
- ML20100A434 + (ML20100A434)
- 05000305/LER-1985-005, :on 850211,exhaust Fan 1A of Auxiliary Bldg Special Ventilation Sys Found Running.Caused by Burnt Out Coil in Solenoid Valve Controlling Air to Zone SV Exhaust Filter 1A Inlet Damper.Valve Replaced + (ML20100A447)
- 05000397/LER-1984-114, :on 841028,gland Steam Condenser Bypass Valve Closed,Tripping Two Condensate Booster Pumps & Causing Loss of Feedwater & Reactor Scram.Caused by Personnel Error. Training Will Be Provided + (ML20100A448)
- ML20100A454 + (ML20100A454)
- ML20100A456 + (ML20100A456)
- ML20100A465 + (ML20100A465)
- 05000361/LER-1984-062, :on 841023,w/unit in Mode 5 & Containment Purge in Progress,Train a of Containment Purge Isolation Sys Actuated by Instrument Failure Signal from Containment Airborne Monitor Channel C + (ML20100A466)
- ML20100A468 + (ML20100A468)
- 05000361/LER-1984-063, :on 841024,w/unit in Mode 5,train a Containment Purge Isolation Sys Actuated by High Radiation Alarm on Containment Airborne Radiation Monitor While RCS Vented + (ML20100A475)
- ML20100A476 + (ML20100A476)
- ML20100A480 + (ML20100A480)
- ML20100A486 + (ML20100A486)
- ML20100A492 + (ML20100A492)
- ML20100A493 + (ML20100A493)
- ML20100A495 + (ML20100A495)
- ML20100A500 + (ML20100A500)
- ML20100A551 + (ML20100A551)
- ML20100A557 + (ML20100A557)
- ML20100A561 + (ML20100A561)
- ML20100A569 + (ML20100A569)
- ML20100A572 + (ML20100A572)
- ML20100A575 + (ML20100A575)
- ML20100A577 + (ML20100A577)
- ML20100A615 + (ML20100A615)
- ML20100A628 + (ML20100A628)
- ML20100A638 + (ML20100A638)
- BECO-84-200, Responds to Generic Ltr 84-23 Re Improvements to Reactor Water Level Instrumentation Sys.Mods Either Rerouting or Preventing Ref Leg Overheating Are in Internal Review Cycle to Evaluate Feasibility & Impact on Safety + (ML20100A644)
- ML20100A646 + (ML20100A646)
- ML20100A659 + (ML20100A659)
- B11379, Forwards Amend 11 to FSAR & Responses to Selected Requests for Addl Info + (ML20100A670)
- W3P84-3337, Forwards Addl Info on Soil Spring Distributions & north- South Bending Capacities in Positive & Negative Directions Re Foundation Basemat Cracks,Per Js Ma 841116,20 & 26 Requests + (ML20100A680)
- ML20100A686 + (ML20100A686)
- ML20100A687 + (ML20100A687)
- ML20100A689 + (ML20100A689)
- 05000249/LER-1985-004-06, :on 850215,level Indicating Switch 3-263-58B Found to Trip at 116.5 Inches Water & Switch 3-263-57B Found to Trip at 127 Inches Water (Differential Pressure).Caused by Setpoint Drift.Switches Adjusted & Recalibr + (ML20100A709)
- 05000397/LER-1985-018, :on 850224,containment Monitoring Sys Temp Indicator Exceeded 150 F for Greater than 8 H.Caused by Circulating Water Sys Cooling Towers Alternately Being Taken Out of Svc for Electrical Repairs + (ML20100A715)
- HL-5089, Responds to NRC Re Violations Noted in Insp Rept 50-321/95-23.Corrective Actions:Peo Disciplined,Operations Personnel Reviewed Applicable Fuel Oil Transfer Procedures. Procedure Rev W/Appropriate Enhancements Implemented + (ML20100A722)
- 05000397/LER-1985-019, :on 850216,temp Monitoring of RHR Pump Room Areas Not Accomplished in Accordance W/Tech Specs.Caused by Incorrect Transference of Instructions from Plant Procedure Deviation to Actual Procedure Used on 850216 + (ML20100A723)
- 05000397/LER-1985-015, :on 850213,fire Detection Instrument Discovered to Have Been Removed from RHR Valve Room During Plant Mod. from 840909-850213 No Fire Detection or Fire Watch Patrol Monitored RHR Valve Room + (ML20100A737)
- ML20100A744 + (ML20100A744)
- 05000397/LER-1985-014, :on 850214,high Pressure Reactor Scram Initiated Due to Actuation of Turbine Bypass Valve 7 Inches Mercury Low Condenser Vacuum Interlock.Normal Scram Recovery Procedures Followed + (ML20100A750)
- ML20100A751 + (ML20100A751)
- ML20100A761 + (ML20100A761)
- ML20100A762 + (ML20100A762)
- ML20100A768 + (ML20100A768)
- ML20100A771 + (ML20100A771)
- ML20100A780 + (ML20100A780)