- B11063, Responds to NRC Re Violations Noted in IE Insp Rept 50-336/80-11.Corrective Actions:Offstream Liquid Effluent Monitors Will Be Installed by 841130 + (ML20095A415)
- ML20095A427 + (ML20095A427)
- ML20095A437 + (ML20095A437)
- ML20095A441 + (ML20095A441)
- ML20095A442 + (ML20095A442)
- 05000254/LER-1995-006-08, :on 951103,TS Surveillance Was Missed Due to Procedure Deficiency.Enhanced Procedure Qcop 500-1 to More Accurately Define RPS EPA Operability + (ML20095A449)
- ML20095A454 + (ML20095A454)
- 05000339/LER-1995-004-03, :on 951111,automatic RT Occurred Due to Loss of B Control Rod Drive Sys Motor Generator Set.Entered Emergency Procedure E-0, RT & Si + (ML20095A455)
- ML20095A458 + (ML20095A458)
- ML20095A463 + (ML20095A463)
- 05000443/LER-1995-007, :on 951103,MSSV Setpoint Testing Failed.Reset Four MSSVs to Required Setpoint & Retested Satisfactorily at Plant + (ML20095A464)
- ML20095A472 + (ML20095A472)
- ML20095A476 + (ML20095A476)
- RBG-18-586, Forwards Operating Shift Experience Tables,Per DG Eisenhut 840531 Request.Info Updates .Shift Advisors Will Not Be Used to Augment Operating Staff + (ML20095A484)
- HL-5065, Informs That Licensee Elected to Defer Augmented Reactor Pressure Vessel Exam for Unit 1 to First Period of Third Insp Interval,Commencing on 960101 + (ML20095A491)
- ML20095A493 + (ML20095A493)
- BECO-92-038, Requests Temporary Waiver of Compliance for 96 H from Plant Startup to Cold Shutdown from Applicable Portions of Plant TS Associated W/Rv Water Level Instrumentation.Supercedes Previous Request + (ML20095A501)
- 05000348/LER-1995-010, :on 951105,ESF Equipment Actuation Occurred Due to Loss of Mfw.Sgfp Lube Oil Pressure Regulating Sys on Both Units Was Properly Adjusted + (ML20095A517)
- ML20095A518 + (ML20095A518)
- ML20095A520 + (ML20095A520)
- ST-HL-AE-1077, Forwards Rev 6 to QA Program Description for Design & Const Phase of Facilities.Changes Clarify Definition of Bechtel Div Quality Policies & Defines Responsibilities for Trend Analysis + (ML20095A521)
- ML20095A531 + (ML20095A531)
- ML20095A532 + (ML20095A532)
- ML20095A535 + (ML20095A535)
- ML20095A540 + (ML20095A540)
- ML20095A545 + (ML20095A545)
- ML20095A549 + (ML20095A549)
- SNRC-1923, Advises That Util Implemented 10CFR73.56, Personnel Access Authorization Requirements for Nuclear Power Plants & Incorporated Required Access Authorization Program Into Site Security Plan.All Elements of Reg Guide 5.66 Met + (ML20095A553)
- ML20095A556 + (ML20095A556)
- ML20095A558 + (ML20095A558)
- 05000458/LER-1992-006, :on 920314,unsecured High Radiation Area Boundary Rope Discovered at Entrance to Drywell.Cause unknown.Non-essential Personnel Authorized RCA Access Directed to Stop Work & Report to Meetings + (ML20095A565)
- ML20095A567 + (ML20095A567)
- ML20095A570 + (ML20095A570)
- ML20095A576 + (ML20095A576)
- ML20095A578 + (ML20095A578)
- ML20095A587 + (ML20095A587)
- ML20095A596 + (ML20095A596)
- ML20095A600 + (ML20095A600)
- ML20095A602 + (ML20095A602)
- ML20095A604 + (ML20095A604)
- ML20095A629 + (ML20095A629)
- ML20095A632 + (ML20095A632)
- SNRC-1924, Advises That J Little (Screening & Badging Administrator) Authorized to Submit Fingerprints & Receive Results Under Criminal History Program.Jl Molini & AF Downs Designated as Alternates in Event of J Little Absence + (ML20095A640)
- 05000219/LER-1992-001-01, :on 920312,rept Received Re Sparks from Status Lights for Undervoltage Protection Circuit in Front of 4,160 Volt Emergency Switchgear.Caused by Design of Lamp Sockets & Circuitry.Damaged Wiring & Fuse Replaced + (ML20095A642)
- ML20095A649 + (ML20095A649)
- ML20095A654 + (ML20095A654)
- ML20095A657 + (ML20095A657)
- ML20095A673 + (ML20095A673)
- 05000341/LER-1992-002, :on 920316,inadvertent Actuation of LPCI Sys Loop Select Logic Occurred,Resulting in Core Flow Decrease & Entry Into Region a of Power/Flow Map.Caused by Short Circuit in Contacts.Meeting Held + (ML20095A674)
- 05000338/LER-1992-008, :on 920319,both Channels of Auxiliary Feedwater Pump Station Blackout Automatic Start Circuit Defeated.Caused by Executing Inadequate Procedure.Test Terminated & Relays Returned to Svc + (ML20095A680)
- ML20095A685 + (ML20095A685)