- ML20092K529 + (ML20092K529)
- LD-92-016, Forwards Response to NRC Re Addl Info for Review of C-E Std Sar.W/Two Oversize Figure Drawings + (ML20092K532)
- 3F0684-09, Special Rept 84-02:on 840312,engineered Safeguards High Pressure Injection Initiated.Caused by Spurious Actuation of Channel 2 Train B.Equipment Replaced & Borated Water Injected + (ML20092K536)
- ML20092K540 + (ML20092K540)
- 05000285/LER-1984-006, :on 840522,unplanned Actuation of Ventilation Isolation Actuation Sys (Vias) Occurred.Vias Actuation Spurious.Alarm Cleared & Vias Lockout Reset Once Filter Replaced + (ML20092K541)
- ML20092K547 + (ML20092K547)
- HL-1946, Application for Amends to Licenses DPR-57 & NPF-5,changing Snubber Functional Test Insp Interval to 18 Months,Per Generic Ltr 90-09 + (ML20092K551)
- ML20092K552 + (ML20092K552)
- ML20092K557 + (ML20092K557)
- HL-2058, Rev to 900921 Application for Amend to License DPR-57, Adding Note to TS Table Re Temporary Bypass of RWCU Differential Flow Isolation Instrumentation When Sys Restoration,Testing or Maint Performed + (ML20092K558)
- ML20092K564 + (ML20092K564)
- 05000387/LER-1984-027, :on 840622,two Grab Samples Required by Tech Spec Action Statements Not Taken within Requisite Time Limits.Caused by Personnel Oversight.Supervisor Met W/ Technicians to Review Responsibilities + (ML20092K566)
- 05000315/LER-1984-007-01, :on 840522,detector Code Programming Error Discovered in Calculational Logic While Modifying Code. Procedure Change Made to Require Independent Line by Line Review of Coding + (ML20092K569)
- ML20092K575 + (ML20092K575)
- 05000366/LER-1992-002-01, :on 920127,Group 5 Primary Containment Isolation Sys Valve 2G31-F001 Closed on RWCU Sys High Differential Flow Isolation Signal.Caused by Personnel Error.Signal Reset & Valve Opened + (ML20092K577)
- ML20092K579 + (ML20092K579)
- ML20092K581 + (ML20092K581)
- ML20092K584 + (ML20092K584)
- ML20092K587 + (ML20092K587)
- ML20092K592 + (ML20092K592)
- 3F0292-10, Responds to NRC Re Violations Noted in Insp Rept 50-302/91-24.Corrective Actions:Missed Surveillance Associated W/Anticipatory Reactor Trips Performed & Canal Seal Plate Placed in Proper Position + (ML20092K593)
- ELV-03462, Forwards Fitness for Duty Performance Data for Jul to Dec 1991 Per 10CFR26.71(d) + (ML20092K594)
- ML20092K596 + (ML20092K596)
- ML20092K598 + (ML20092K598)
- ML20092K603 + (ML20092K603)
- ML20092K606 + (ML20092K606)
- ML20092K610 + (ML20092K610)
- ML20092K612 + (ML20092K612)
- ML20092K613 + (ML20092K613)
- ML20092K626 + (ML20092K626)
- 05000457/LER-1995-006-05, :on 950823,failed to Perform Surveillance as Required When Afd Alarm Was Inoperable Due to Personnel Error.Entered Lcoar,Started Surveillance & Updated Ppc + (ML20092K632)
- 05000370/LER-1984-012-01, :on 840510,reactor Trip Occurred When Steam Generator C Level Dropped Below lo-lo Level Reactor Trip Setpoint.Caused by Main Feedwater Transient.Feedwater Regulator Pilot Valve Stem Cleaned + (ML20092K636)
- ML20092K638 + (ML20092K638)
- 05000483/LER-1992-001, :on 910912,licensed Operators Performed TS 4.7.7 Surveillance of Train a Emergency Exhaust Sys for Only 9 H & 21 Minutes.On 920121,discovered Flow Not Maintained Through Exhaust.Individuals Coached + (ML20092K644)
- ML20092K653 + (ML20092K653)
- ML20092K660 + (ML20092K660)
- 05000327/LER-1992-001-01, :on 920117,determined That 2B-B DG Load Sequence Timer Associated W/Train B Electric Board Room Air Handling Unit Not Calibr Per Ts.Caused by Procedural Inadequacies.Site Stds Revised + (ML20092K662)
- ML20092K663 + (ML20092K663)
- B11238, Forwards Addl Info Re Protection Against Postulated Pipe Breaks Outside Containment & Hydrogen Recombiner Bldg post- Accident Exhaust Sys,Per Auxiliary Sys Branch 840613 Request.Lists FSAR Figures Provided on 840613 + (ML20092K664)
- ML20092K674 + (ML20092K674)
- 05000353/LER-1995-010, :on 950820,reactor Scram Resulted from High Rv Pressure Signal Caused by Malfunctioning Relay Associated W/Electrohydraulic Control Sys.Replaced KT106 Relay Boards for Units 1 & 2 ECS Sys + (ML20092K676)
- ML20092K678 + (ML20092K678)
- 05000353/LER-1992-002-01, :on 920119,momentary Spike Occurred on D Channel of Unit 2 Refueling Floor Exhaust Duct Radiation Monitor.Caused by Unexpected Equipment Failure.Radiation Sensor Was Replaced on 920131 + (ML20092K682)
- ML20092K684 + (ML20092K684)
- 05000285/LER-1992-001, :on 920121,alarms That Indicated Loss of 13.8 Kv Electric Sys.Caused by Inadequate Design of RM-041/042 & 043 Sample Pump Motor Control.Sample Pump Restarted + (ML20092K688)
- ML20092K695 + (ML20092K695)
- ML20092K700 + (ML20092K700)
- ML20092K702 + (ML20092K702)
- ML20092K704 + (ML20092K704)
- ML20092K712 + (ML20092K712)
- ML20092K719 + (ML20092K719)