Text
-
l l
t l
GPU Nuclear Corporation U
OM "oute 44' sout" P.O. Box 480 Middletown. Pennsylvania 17057-0480 (717) 944-7621 Wnter's Direct Dial Nurnber.
(717) 948-8005 September 20, 1995 C311-95-2391 U. S. Nuclear Regulatory Commission Att: Document Control Desk Washington, DC 20555
Dear Sir:
Subject:
Three Mile Island Nuclear Station, Unit 1 (TMI-1)
Operating License No. DPR 50 Docket No. 50-289 Technical Specification Change Request No. 227, Supplement 2 Technical Specification Change Request (TSCR) No. 227, submitted on January 16,1995, incorporates improvements from the Standard Technical Specifications (STS) for B&W Plants (NUREG-1430). In a lettcc dated June 22,1995 GPU Nuclear responded to a May 16, 1995 request for additional information (RAI) in TSCR No. 227, Supplement 1.
The purpose of this letter is to submit a second revision to TSCR No. 227 as requested by the NRC staff in a conference call on August 28,1995. Attached are the mvised pages 4 -31, 4-32, and 4-33 which incorporate a change in Technical Specification (TS) Section 4.4.1.5 where the NRC staff requested that, rather than deleting this specification altogether, a reference to the containment inspection requirements of Appendix J be included.
Also, the changes to the Bases for TS 3.1, " Reactor Coolant System," proposed by the original TSCR No. 227 are being withdrawn at this time.
A double margin bar has been used to show the change on page 4-31. Please replace the affected pages 4-31,4-32, and 4-33 with the attached replacement pages and remove the proposed pages 3-2 and 3-2a from the TSCR No. 227 package. The double margin bar is I
provided to facilitate review and should be removed prior to issuance of the amendment.
Also enclosed is a Certificate of Service for this request, certifying service to the chief
~$l '
9509260039 950920 PDR ADOCK 05000289 t
I P
... " C311-95-2391 Page 2 of 2 executives of the township and county in which the facilities am located, as well as the designated official of the Commonwealth of Pennsylvania, Bureau of Radiation Protection.
Pursuant to 10 CFR 50.91(a)(1), the proposed change to the TMI-l Technical Specifications has been distributed as specified by 10 CRF 50.4. The significant hazards consideration determination as originally submitted with TSCR No. 227 is unaffected by this revision. The signed copy of the Cenificate of Service to the chief executives of Iondonderry Township and Dauphin County and the designated mpresentative of the Commonwealth of Pennsylvania is also enclosed.
- Sincemly, J. Knubel Vice Pmsident and Director, TMI MRK
Enclosures:
- 1) TMI-l Technical Specifications Revised Pages
- 2) Cenificate of Service for TMI-l TSCR No. 227 cc: Administrator, Region I TMI Senior Resident Inspector TMI-l Senior Project Manager i
1 i
METROPOLITAN EDISON COMPANY
~
JERSEY CENTRAL POWER & LIGHT COMPANY AND PENNSYLVANIA ELECTRIC COMPANY THREE MILE ISLAND NUCLEAR STATION, UNITS 1 Operating License No. DPR-50 Docket No. 50-289 Technical Specification Change Request No. 227, Supplement 2 COMMONWEALTH OF PENNSYLVANIA )
) SS:
COUNTY OF DAUPHIN
)
This Technical Specification Change Request supplement is submitted in support of Licensee's request to change Appendix A to Operating License No. DPR-50 for Three Mile Island Nuclear Station, Unit 1. As part of this request, proposed replacement pages for Appendix A are also included.
GPU NUCLEAR CORPORATION BY:
-2
/ fce President and Director, TMI Swom and Subsc ' bed to before me this dday of n264,1995.
hg Debra S c Public Notary Pubh..c l.cndonderry
., aup in Coun My commisson xpires July 4.19 a embur, Penreylvarna kax;aton ol Nc*aTS
--~~z
UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION IN THE MA' ITER OF DOCKET NO. 50-289 GPU NUCLEAR CORPORATION LICENSE NO. DPR-50 CERTIFICATE OF SERVICE This is to certify that a copy of Technical Specification Change Request (TSCR) No. 227, Supplement 2 to Appendix A of the Operating License for Three Mile Island Nuclear Station Unit 1, has, on the date given below, been filed with executives of Iondonderry Township, Dauphin County, Pennsylvania; Dauphin County, Pennsylvania; and the Pennsylvania Depanment of Environmental Resources, Bureau of Radiation Protection, by deposit in the United States mail, addressed as follows:
Mr. Jay H. Kopp, Chairman Mr. Russell L. Sheaffer, Chairman Board of Supervisors of Board of County Commissioners Iondonderry Township of Dauphin County R. D. #1, Geyers Church Road Dauphin County Counhouse Middletown, PA 17057 Harrisburg, PA 17120 Director, Bureau of Radiation Protection PA. Dept. of Environmental Resources P. O. Box 2063 Harrisburg, PA 17120 Attn: Mr. Stan P. Maingi GPU NUCLEAR CORPORATION j
l BY:
C V' e President and Director, TMI DATE:
l