Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ST-HL-AE-3960, Special Rept:On 911212,standby Diesel Generator 11 Nonvalid Failure Occurred Due to High Resistance of Relay Contacts within Instantaneous Preposition Board.Instantaneos Preposition Board Replaced & Similar Relays to Be Inspected + (ML20087D344)
- 05000263/LER-1984-009, :on 840207,EFT Sys (Control Room HVAC) Transferred to Emergency Mode Due to Toxic Chemical Detector Tape Break.Caused by Excessive Friction Between Optics Block & Tape.Spring Tension Reduced & Block Replaced + (ML20087D345)
- ML20087D349 + (ML20087D349)
- ML20087D350 + (ML20087D350)
- 05000395/LER-1984-011, :on 840210,reactor Tripped Due to Turbine Trip on Low Discharge Pressure of shaft-driven Oil Pump.Caused by Procedural Inadequacy in Not Verifying Motor Suction Pump Operation Prior to Restart + (ML20087D357)
- ML20087D358 + (ML20087D358)
- ML20087D359 + (ML20087D359)
- ML20087D362 + (ML20087D362)
- ML20087D363 + (ML20087D363)
- ML20087D365 + (ML20087D365)
- ML20087D369 + (ML20087D369)
- DCL-95-153, Forwards Public Files Version of Revised Corporate Emergency Response Plan Implementing Procedures,Including Rev 14 to 1.1,Rev 8 to 1.2,Rev 11 to 2.1,Rev 5 to 3.1,Rev 12 to 3.2,Rev 6 to 3.5,Rev 14 to 4.3.W/950807 Release Memo + (ML20087D371)
- ML20087D375 + (ML20087D375)
- ML20087D380 + (ML20087D380)
- ML20087D382 + (ML20087D382)
- ML20087D383 + (ML20087D383)
- 05000311/LER-1984-002-01, :on 840209,RHR Common Suction Valve 2RH1 Inadvertently Shut,Resulting in Loss of RHR Flow Through Rcs.Caused by Bezel Covers Not Removed to Reflect Release of Breaker Tags + (ML20087D384)
- ML20087D386 + (ML20087D386)
- ML20087D387 + (ML20087D387)
- BSEP-95-0299, Requests Rev to Ts,Revising MCPR Limit,Ts 5.3.1 to Reflect New Fuel Type & Acceptable Range of Na Pentaborate Concentration for Standby Liquid Control Sys Shown in TS Figure 3.1.5-1 That Reflects Changes to Poison Matl + (ML20087D391)
- ML20087D392 + (ML20087D392)
- ML20087D394 + (ML20087D394)
- ML20087D400 + (ML20087D400)
- RBG-17-225, Forwards Rev 2 to Physical Security Plan & Explanation of Major Changes to Facilitate Review.Rev & Explanation Withheld (Ref 10CFR2.790) + (ML20087D403)
- ML20087D406 + (ML20087D406)
- ML20087D411 + (ML20087D411)
- ML20087D412 + (ML20087D412)
- ML20087D418 + (ML20087D418)
- ML20087D419 + (ML20087D419)
- ML20087D420 + (ML20087D420)
- A00027, Unit 1 Saltwater 1 Inch Half Coupling Weld Failure + (ML20087D421)
- ML20087D432 + (ML20087D432)
- ML20087D435 + (ML20087D435)
- 05000247/LER-1984-002, :on 840105,two of Four MSIVs Did Not Fully Close within 5 Tech Spec Requirement.Caused by Dried Out Valve Shaft Lubrication.Shaft & Packing Lubricated + (ML20087D436)
- BSEP-84-0531, Special Rept 2-SR-84-4:on 840204,fire Barrier Limiting Conditions for Operation Initiated to Permit Repair of Inoperable Fire Door 108.Distortion of Door Upper Hinge Prevented Door from Latching Properly.Door Returned to Svc + (ML20087D439)
- ML20087D440 + (ML20087D440)
- ML20087D449 + (ML20087D449)
- ML20087D451 + (ML20087D451)
- ML20087D460 + (ML20087D460)
- 05000333/LER-1995-012-01, :on 950526,primary Containment Makeup Nitrogen Flow Monitoring Surveillance Missed Due to Personnel Error. Applicable Surveillance Tp (ST-40D) Change to Provide Alternate Means of Monitoring Subj Flow + (ML20087D468)
- ML20087D469 + (ML20087D469)
- ML20087D472 + (ML20087D472)
- ML20087D474 + (ML20087D474)
- ML20087D476 + (ML20087D476)
- ML20087D477 + (ML20087D477)
- 05000280/LER-1984-003-01, :on 840206,reactor Tripped Due to Low Steam Generator Level W/Steam Flow/Feed Flow Mismatch in Steam Generator A.Caused by Tripped Feedwater Breaker Closing. Breaker Replaced + (ML20087D486)
- ML20087D497 + (ML20087D497)
- ML20087D504 + (ML20087D504)
- HL-5008, Bound Steam Supply Valve Which Resulted in Inoperable HPCI Sys + (ML20087D506)
- ML20087D511 + (ML20087D511)
- 05000321/LER-1995-006, :on 950711,HPCI Was Inoperable Due to Bound Steam Supply Isolation Valve.Installed Spacer Ring in Packing Gland,Replaced Valve Stem,Repaired Valve Bonnet & Returned HPCI Sys to Svc + (ML20087D513)