Sqn,Unit 2 Cycle 6 Insp SG Tubing Insp Results
ML20087D362
Person / Time
Site: Sequoyah 
Issue date: 08/07/1995
From:
TENNESSEE VALLEY AUTHORITY
To:
Shared Package
ML20087D361 List:
References
NUDOCS 9508100298
Download: ML20087D362 (18)


Text

..

,, -..g s.

(

4 ENCLOSURE' SEQUOYAH NUCLEAR PLANT UNIT 2 ~

CYCLE 6 INSPECTION.

. AUGUST 1994 STEAM GENERATOR TUBING INSPECTION RESULTS (S57 950725 912) i I

l i

t-9508100298 950807 PDR ADOCK 05000328 D

PDR

1

)

-SEQUOYAH NUCLEAR PLANT UNIT 1 CYCLE 6 INSPECTION AUGUST 94 i

TABLE OF CONTENTS Table 1 Inspection Summary Table 2.1 SG 1 Inspection Table 2.2 SG 2 Inspection Table 2.3 SG 3 Inspection Table 2.4 SG~4 Inspection Table 3.1 SG 1 List of Indications and Tubes Plugged Table 3.2 SG 2 List of Indications and Tubes Plugged Table 3.3 SG 3 List' of Indications and Tubes Plugged Table 3.4

'SG 4 List of Indications and Tubes Plugged Table 4 Nomenclature i

_-m

T

~

l, 1

SEQUOYAH NUCLEAR PLANT UNIT 2 CYCLE 6 INSPECTION i

AUGUST 1994 l

)

TABLE 1 INSPECTION

SUMMARY

' EDDY CURRENT'(Tube Exams)

SG 1 SG 2 SG 3 SG 4 Full length bobbin 3377 3363 3370 3379' i

Support Plate RPC 33 27 27 27 Free-span RPC 5

4 3

11 Top-of-Tubesheet RPC 1530 3363 2125 1517 U-Bend RPC 187 188 183 188 Total Exam Completed 5132 6945 5708 5122 j

Total Tubes Examined 3377 3363 3370 3379 INDICATIONS (Tubes)

SG 1 SG'2 EG_1 SG 4 Defects

(>= 40% wall loss)

PWSCC HTS 0

13 3

0 ODSCC TSP O

O 5

2 AVB Wear 0

3 0

0 Cold Leg Wastage 0

0 2

0 PWSCC U-Bend-14 22 9

0 OD Indications 0

1 0

0 Degradation

(>= 20% and < 40% wall loss)

ODSCC TSP O

1 4

17 AVB Wear 10 16 3

3 Cold Leg Wastage 2

10 7

3 OD Indications 0

0 1

11 MFG. Flaw 4

0 1

0 ODSCC HTS 0

1 6

0 Imperfections (< 20% wall loss)

AVB Wear 2

6 1

4 Cold Leg Wastage 1

5 2

5 OD Indications 0

0 0

3 MFG. Flaws 3

2 1

'O ODSCC HTS 0

0 1

2 PLUGGING STATUS Previously plugged tubes 11 25 18 9

' Plugged Cycle 7 by Damage Mechanism PWSCC HTS 0

13 3

0 ODSCC TSP O

O 5

2 PWSCC U-Bend 14 22 9

0 AVB Wear 0

3 0

0 Cold Leg Wastage 0

0 3

0 OD Indication 0

1 0

0-Total Plugged Cycle 7 14 39 20 2

TOTAL TUBES PRESENTLY PLUGGEQ 25 64 38 11

~....,

z. $_ '.

SEQUOYAH NUCLEAR PLANT' UNIT 2 C1'CLE 6 INSPECTION AUGUST 1994 TABLE 2.1 STEAM GENERATOR INSPECTION SG 1

. Exam Extent Probe Tvoe Tubes' i

GENERAL' DEFECT EXAMS i

HTE-CTE Bobbin Coil 3377

' 1

- l SPECIALTY EXAMS Hot Leg Top of Tubesheet RPC 1530~

Support Plate Intersection RPC 33 Free-span RPC

-5 U-Bend RPC 187 TOTAL TUBES EXAMINED 3377 r

Y

-f k

ya v-

.e.

vs-r--

w

m-

_ ^

r SEQUOYAH NUCLEAR PLANT UNIT 2 CYCLE 6 INSPECTION AUGUST 1994 TABLE 2.2

-l i

STEAM GENERATOR INSPECTION SG 2 Exam Extent Probe Type Tubes GENERAL DEFECT EXAMS HTE-CTE Bobbin Coil 3363 SPECIALTY EXAMS Hot Leg Top of Tubesheet RPC-3363 Support Plate Intersection RPC 27 i

Free-span RPC 4

U-Bend RPC 188 TOTAL TUBES EXAMINED 3363 l

4 i

.i

~

y i

b

'T

.# g SEQUOYAH NUCLEAR PLANT UNIT 2 CYCLE 6 INSPECTION AUGUST 1994 TABLE 2.3 STEAM GENERATOR INSPECTION SG 3

)

Exam Extent Probe Tvoe Tubes GENERAL DEFECT EXAMS HTE-CTE Bobbin Coil

-3370 SPECIALTY EXAMS Hot Top of Tubesheet RPC 2125 Support Plate Intersection RPC 27 Free-span RPC 3

U-Bend RPC 183 TOTAL TUBES EXAMINED 3370 i

I l

i

7 4

SEQUOYAH NUCLEAR PLANT UNIT 2 CYCLE 6 INSPECTION

[

AUGUST 1994

)

TABLE 2.4 STEAM GENERATOR INSPECTION SG 4

~ Exam Extent Probe Tvoe.

Tubes-GENERAL DEFECT EXAMS HTE-CTE Bobbin Coil 3379 1

SPECIALTY EXAMS Hot Top of Tubesheet RPC 1517 Support Plate Intersection RPC 27 Free-span

.RPC 11-U-Bend RPC 188 TOTAL TUBES EXAMINED 3379 1

I SEQUOYAH NUCLEAR PLANT UNIT 2 CYCLE 6 INSPECTION AUGUSP 1994 l

TABLE 3.1

, LIST OF INDICATIONS AND TUBES PLUGGED SG 1 Boy Col Location Characterization Resolution i

Initial Sample 1

16 H07+ 7.11 SAI U-Bend PWSCC Plug Tube 1

26 H07+ 7.04 SAI U-Bend PWSCC Plug Tube 1

36 H07+ 2.87 SAI U-Bend PWSCC Plug Tube 1

38 H07+ 2.79 SAI U-Bend PWSCC Plug Tube 1

45 H07+ 6.84 SAI U-Bend PWSCC Plug Tube 1

55 H07+ 2.89 SAI U-Bend PWSCC Plug Tube 1

61 H07+ 2.81 SAI U-Bend PWSCC Plug Tube 1

72 H07+ 2.95 SAI U-Bend PWSCC Plug Tube 1

74 H07+ 5.62 SCI U-Bend PWSCC Plug Tube H07+ 5.98 SCI U-Bend PWSCC H07+ 7.19 SCI U-Bend PWSCC 1

85 H074 3.03 SAI U-Bend PWSCC Plug Tube H07+ 5.33 SCI U-Bend PWSCC H07+ 5.00 SCI U-Bend PWSCC 1

87 H07+ 2.80 SAI U-Bend PWSCC Plug Tube 1

88 H07+ 3.30 SAI U-Bend PWSCC Plug Tube H07+ 5.31 SCI U-Bend PWSCC 1

90 H07+ 3.00 SAI U-Bend PWSCC Plug Tube 1

92 H07+ 7.09 SAI U-Bend PWSCC Plug Tube 12 24 HTS +38.39 <40 MFG. Flaw (1) 19 38 AV2+ 0.00 29 AVB Wear (1) 21 55 HTS +37.77 <40 MFG. Flaw (1) 21 66 H02+47.33 <40 MFG. Flaw (1) 25 10 CTS + 8.76 11 MFG. Flaw (2) 26 52 H02+35.42 20 MFG. Flaw (1) 27 31 AV2+ 0.00 22 AVB Wear (1)

AV3+ 0.00 22 AVB Wear (1) 29 63 AV2+ 0.00 24 AVB Wear (1)

AV3+ 0.00 38 AVB Wear (1) 32 64 AV2+ 0.00 24 AVB Wear (1)

AV3+ 0.00 21 AVB Wear (1)

AV4+ 0.00 18 AVB Wear (2) 33 51 AV2+ 0.00 31 AVB Wear (1) 33 57 AV3+ 0.16 36 AVB Wear (1)

AV2- 0.08 37 AVB Wear (1)

~

SEQUOYAH NUCLEAR PLANT UNIT 2 CYCLE 6 INSPECTION AUGUST 1994 TABLE 3.1 LIST OF INDICATIONS AND TUBES PLUGGED (Continued)

SG 1 B2E ggl Location Characterization Resolution Initial Sample (Continued) 33 59 AV1+ 0.00 31 AVB Wear (1)

AV2+ 0.16 24 AVB WEAR (1)

AV3- 0.11 28 AVB Wear (1) 34 19 C01+ 0.00 23 Cold Leg Wastage (1) 34 53 AV2+ 0.00 35 AVB Wear (1)

AV3+ 0.00 28 AVB Wear (1) 36 66 AV3+ 0.00 23 AVB Wear (1) 37 21 CTS +34.98 18 MFG. Flaw (2) 37 62 AV2+ 0.00 21 AVB Wear (1)

AV3+ 0.00 30 AVB Wear (1) 39 45 AV2+ 0.00 19 AVB Wear (2) 42 62 HTS +14.45 10 MFG. Flaw (2) 44 34 C01+ 0.00 33 Cold Leg Wastage (1) 46 50 C01+ 0.22 19 Cold Leg Wastage (2)

Steam Generator 1 Inspection Initial Sample Results have been classified as Category C-2.

First Expansion Sample No indications Steam Generator 1 Inspection First Expansion Sample Results have been classified as Category C-1.

l (1) - Retest Future Outage (2) - None Required

SEQUOYAH NUCLEAR PLANT UNIT 2 CYCLE 6 INSPECTION AUGUST 1994 TABLE 3.2 j

LIST OF INDICATIO_NS AND TUBES PLUGGED SG 2 i

Row Cal Location Characterization Resolution Initial Sample i

1 2

H07+ 7.16 SAI U-Bend PWSCC Plug Tube 1

11 H07+ 2.56 SAI U-Bend PWSCC Plug Tube 1

19 H07+ 2.87 SAI U-Bend PWSCC Plug-Tube 1

32 H07+ 2.80 SAI U-Bend PWSCC Plug Tube H07+ 2.91 SAI U-Bend PWSCC l

1 39 H07+ 2.58 SAI U-Bend PWSCC Plug Tube 1

42 H07+ 2.50 SAI U-Bend PWSCC Plug Tube 1

49 H07+ 2.87 MAI U-Bend PWSCC Plug Tube 1

50 H07+ 5.19 SCI U-Bend PWSCC Plug Tube H07+ 6.33 SCI U-Bend PWSCC 1

51 H07+ 7.15 MAI U-Bend PWSCC Plug Tube 1

52 H07+ 6.17 SCI U-Bend PWSCC Plug Tube 1

53 H07+ 7.60 MAI U-Bend PWSCC Plug Tube 1

63 H07+ 7.16 SAI U-Bend PWSCC Plug Tube 1

65 H07+ 7.10 SAI U-Bend PWSCC Plug Tube 1

67 H07+ 4.01 SCI U-Bend PWSCC Plug Tube 1

68 H07+ 5.25 SCI U-Bend PWSCC Plug Tube 1

78 H07+ 8.28 SAI U-Bend PWSCC Plug Tube 1

79 H07+ 8.21 SAI U-Bend PWSCC Plug Tube 1

80 H07+ 2.95 SAI U-Bend PWSCC Plug Tube i

1 86 H07+ 7.48 SAI U-Bend PWSCC Plug Tube 1

87 H07+ 2.76 SAI U-Bend PWSCC Plug Tube 1

89 H07+ 7.23 SAI U-Bend PWSCC Plug Tube H07+ 5.10 SAI U-Bend PWSCC 1

93 H07+ 7.19 SCI U-Bend PWSCC Plug Tube H07+ 6.43 SCI U-Bend PWSCC H07+ 6.83 SCI U-Bend PWSCC 3

44 HTS-1.02 SAI TTS PWSCC Plug Tube 3

78 CTS +48.25 10 MFG. Flaw (2) 6 93 C01+ 0.00 28 Cold Leg Wastage (1) 7 59 HTS-1.47 SAI TTS PWSCC Plug Tube 8

49 HTS-1.14 SAI TTS PWSCC Plug Tube 8

53 HTS- 0.92 SAI TTS PWSCC Plug Tube 8

57 HTS-1.45 SAI TTS PWSCC Plug Tube 8

59 HTS- 0.22 SAI TTS PWSCC Plug Tube 8

63 HTS-1.80 SAI TTS PWSCC Plug Tube

F 1

-(

~

SEQUOYAH NUCLEAR PLANT UNIT 2 CYCLE 6 INSPECTION AUGUST 1994 TABLE 3.2 LIST OF INDICATIONS AND TUBES PLUGGED (Continued)

SG 2 Pow Col Location Characterization Resolution Initial Sample (Continued) 8 66 HTS- 0.93 SAI TTS PWSCC Plug Tube 8

75 HTS- 0.96 SAI TTS PWSCC Plug Tube 12 92 C01- 0.05 32 Cold Leg Wastage (1) 14 63 HTS + 2.07 <40 TTS ODSCC (1) 16 73 HTS- 0.10 SAI TTS PWSCC Plug Tube 17 28 AV3- 0.08 30 AVB Wear (1) 18 89 C01+ 0.05 20 Cold Leg Wastage (1) 19 28 AV1- 0.08 27 AVB Wear (1) 21 37 H01+42.53 61 OD Indication Plug Tube 22 38 HTS- 0.75 SAI TTS PWSCC Plug Tube 22 41 AV2- 0.08 24 AVB Wear (1) 23 69 AV2+ 0.00 31 AVB Wear (1)

AV3+ 0.00 27 AVB Wear (1) 24 61 AV2+ 0.00 29 AVB Wear (1) 24 63 AV2+ 0.00 29 AVB Wear (1) 24 67 AV2- 0.14 41 AVB Wear Plug Tube AV3- 0.29 42 AVB Wear 25 54 HTS- 0.96 SAI TTS PWSCC Plug Tube 26 70 AV3+ 0.21 27 AVB Wear (1) 27 65 AV2+ 0.00 26 AVB Wear (1)

AV3+ 0.00 20 AVB Wear (1) 29 32 AV2- 0.22 28 AVB Wear (1)

AV3+ 0.03 31 AVB Wear (1)

AV4+ 0.11 31 AVB Wear (1) 29 37 AV2+ 0.00 18 AVB Wear (2)

AV3+ 0.03 16 AVB Wear (2) 29 42 AV1- 0.27 27 AVB Wear (1)

AV2- 0.08 29 AVB Wear (1) j AV3+ 0.00 37 AVB Wear (1)

AV4- 0.13 18 AVB Wear (2) 29 56 C04+ 0.08 21 Cold Leg Wastage (1) l 30 44 H04+ 2.i66 9

MFG. Flaw (2) 32 54 AV2+ 0.00 17 AVB Wear (2) j AV3+ 0.00 37 AVB Wear (1) l 32 55 AV1+ 0.16 25 AVB Wear AV2- 0.08 32 AVB Wear AV2- 0.53 20 AVB Wear AV3- 0.18 40 AVB Wear Plug Tube l

1

W.

y dr SEQUOYAH NUCLEAR PLANT UNIT 2 CYCLE 6 INSPECTION AUGUST 1994 4

TABLE 3.2 LIST OF INDICATIONS AND TUBES PLUGGED (Continued)-

SG 2

'l Egg Egl Location Characterization Resolution l

Initial Sample (Continued) 32 79 Col- 0.08 32 Cold Leg Wastage (1) 33 49 AV1+ 0.00- 26 AVB Wear (1)

AV2+ 0.00 24 AVB Wear (1)

AV3+ 0.00 134 AVB Wear (1)

AV4+ 0.00 21 AVB Wear

-(1) 33 62 AV3+ 0.00 20 AVB Wear (1) 34 17 Col- 0.08 15 Cold Leg Wastage (2) 34 63 AV1+ 0.00 20 AVB Wear (1)

AV2+ 0.00 39 'AVB Wear (1)

AV3+ 0.00 23 AVB Wear' (1) 34 64

=AV1+ 0.00 21 AVB Wear AV2+ 0.00 41 AVB Wear-Plug Tube AV3+ 0.00 18 AVB Wear 35 55 H02- 0.10 <40 TSP ODSCC (1) i i

36 18 C01+ 0.18 22 Cold Leg Wastage (1) 37 21 C01+ 0.08 16 Cold Leg Wastage (2) 38 24 C01+ 0.16 29 Cold Leg Wastage (1) 38 46 AV3+ 0.00 17 AVB Wear.

(2)

AV4+ 0.00 18 AVB Wear' (2) 39 49 AV3+ 0.00 19 AVB Wear (2)

AV4+ 0.00 17 AVB Wear' (2)-

42 31 C01- 0.19-25 Cold Leg Wastage (1)'

42 64 C01+ 0.05 20 Cold Leg Wastage (1) 42 66 C01+ 0.03 14 Cold Leg 1 Wastage (2) 43 63 C01- 0.10 27 Cold Leg Wastage

-(1) 44 33 C01+ 0.19 4

Cold' Leg Wastage (2) 46 48 C01+ 0.02 13 Cold Leg' Wastage (2)

Steam Generator 2 Inspection Initial Sample Results have been c

- classified as Category C-2.

First Expansion Sample 12 19 HTS-1.43 SAI TTS PWSCC Plug. Tube Steam Generator 2 Inspection First Expansion Sample Results have been classified as Category C-2.

T SEQUOYAH NUCLEAR PLANT UNIT 2 CYCLE 6 INSPECTION AUGUST 1994 TABLE 3.2 LIST OF INDICATIONS AND TUBES PLUGGED (Continued)

SG 2 Row Col location Characterization Resolution Second Expansion Sample No Indications Steam Generator 2 Inspection Second Expansion Sample Results have been classified as Category C-1.

(1) - Retest Future Outage (2) - None Required i

1 y.

SEQUOYAH NUCLEAR PLANT UNIT 2 CYCLE 6 INSPECTION AUGUST 1994 TABLE 3.3 LIST OF INDICATIONS AND TUBES PLUGGED SG 3 Row E21 Location Characterization Resolution Initial Sample 1

1 H07+ 2.62 SAI U-Bend PWSCC Plug Tube 1

7 H07+ 7.30 MAI U-Bend PWSCC Plug Tube 1

13 H07+ 7.37 SAI U-Bend PWSCC Plug Tube 1

14 H07+ 7.36 SAI U-Bend PWSCC Plug Tube l'

-32 H07+ 3.74 SAI U-Bend PWSCC Plug Tube 1

34 H07+ 4.16 SAI U-Bend PWSCC Plug Tube 1

35 H07+ 3.53 SAI U-Bend PWSCC Plug Tube 1

43 H07+ 7.48 SCI U-Bend PWSCC Plug Tube 1

44 H07+ 7.46 SCI U-Bend PWSCC' Plug Tube 5

1 C01+ 0.05 35 Cold Leg Wastage (1) 6 51 H01+ 0.09 SAI TSP ODSCC Plug Tube 8

2 C01+ 0.00 31 Cold Leg Wastage (1) 8 54 H01+ 0.17 SAI TSP ODSCC Plug Tube 8

56 H0l+ 0.05 <40 TSP ODSCC (1) 10 39 HTS + 1.36 <40 -TTS ODSCC (1) 10

61. HTS + 1.58 29.

TTS ODSCC (1) 10 62 HTS + 1.04 13 TTS ODSCC (2) 11 2

C01+ 0.00 28 Cold Leg Wastage (1) 12 46 HTS + 1.12 30 TTS ODSCC (1) 13 8

H01+ 0.19 SAI TSP ODSCC Plug Tube 13 46 HTS + 1.31 <40 TTS ODSCC (1) 13 47 HTS + 1.60 <40 TTS ODSCC (1)~

14 3

C01+ 0.00-28 Cold Leg Wastage (1) 14 20 H02- 0.02 <40 TSP ODSCC (1) 14 50 HTS-1.03 SAI TTS PWSCC Plug Tube 17 30 H01+ 0.19 MAI TSP ODSCC Plug Tube AV3+ 0.00 -17 AVB Wear

'19 7

H01+ 0.19 SAI' TSP ODSCC

' lug Tube 19 64 AV2+ 0.00 27 AVB Wear

(?)

25 9

C01+ 0.08 38 Cold Leg Wastage (1?

28 45 AV3+ 0.00 21 AVB Wear (1) 32 16 'C01+ 0.00 48 Cold Leg Wastage Plus Tube 3

32 38 CTS + 5.03 17 MFG. Flaw (2) 32 68 H01+ 1.00 36 OD Indication (1) 33 79 C01- 0.10 14 Cold Leg Wastage (2) 34 16 C01- 0.18 18 Cold Leg Wastage (2)

SEQUOYAH NUCLEAR PLANT UNIT 2 CYCLE 6 INSPECTION AUGUST 1994 i

TABLE 3.3 LIST OF INDICATIONS AND_ TUBES PLUGGEO (Continued)

SG 3 Rgy Col Location Characterization Resolution Initial Sample (Continued) 34 21 H01+ 0.20 <40 TSP ODSCC (1) 34 43 AV2+ 0.00 29 AVB Wear (1)

AV3+ 0.00 34 AVB Wear (1)

AV4+ 0.00 24 AVB Wear (1) 34 78 C01- 0.03 22 Cold Leg Wastage (1) 35 17 Col- 0.08 20 Cold Leg Wastage (1) 37 65 HTS + 1.31 35 TTS ODSCC (1) 43 44 H04+ 0.08 <40 TSP ODSCC (1) 44 62 C01- 0.24 39 Cold Leg Wastage Plug Tube 45 36 C01- 0.05 42 Cold Leg Wastage Plug Tube Steam Generator 3 Inspection Initial Sample Results have been classified as Category C-2.

First Expansion Sample 23 21 HTS- 0.39 SAI TTS PWSCC Plug Tube 23 28 HTS-1.17 SAI TTS PWSCC Plug Tube Steam Generator 3 Inspection First Expansion Sample Results have been classified as Category C-2.

Second Expansion Sample No Indications Steam Generator 3 Inspection Second Expansion Sample Results have been classified as Category C-1.

(1) - Retest Future Outage

_(2) - None Required

l 7TQ m.

SEQUOYAH NUCLEAR PLANT UNIT 2 1

CYCLE 6 INSPECTION 1

AUGUST 1994 TABLE 3.4 LTST OF INDICATIONS AND TUBES PLUGGED SG 4 Eny gal Location Characterization Resolution Initial Sample i

1 94 H02- 0.38 <40 TSP ODSCC (1) 2 40 H01- 0.03 <40 TSP ODSCC (1) 2 55 H01- 0.03 <40 TSP ODSCC (1) 8 46 H01+ 0.23 SAI-TSP ODSCC Plug Tube 9

38 H01+ 0.11 <40 TSP ODSCC (1) 11 3

C01+ 0.05 14 Cold Leg Wastage (2) 11 9

H01+16.14 36 OD Indication (1) j 11 67 HTS + 1.87 18 TTS ODSCC (2) 11 86 H01+16.22 <40 OD Indication (1) 12 45 H01+ 0.00 <40 TSP ODSCC (1) 12 67 HTS + 0.96 14 TTS ODSCC (2) 12 72 H01- 0.08 <40 TSP ODSCC (1) 14 92 H01+ 0.00 <40 TSP ODSCC (1) 17 15 H01+15.92 <40 OD Indication (1) 18 33 H05- 0.03 <40 TSP ODSCC (1) 20 60 H01+ 0.08 <40 TSP ODSCC (1) 20 69 Hol- 0.08 <40 TSP ODSCC (1) 20 72 H01+15.42 13 OD Indication.

(2) 20 80 H01+15.43 14 OD Indication (2) 21 19 C05- 0.16 11 Cold Leg Wastage (2) 22 17 C04- 0.16 <40 Cold Leg Wastage (1)

C05- 0.19 <40 Cold Leg Wastage (1) 23 64 H01+ 0.00 <40 TSP ODSCC (1) 24 21 H01+15.93 15 OD Indication (2) 24 27 H01+16.09 <40 OD Indication (1) 24 28 H01+15.94 <40 OD Indication (1) 26 71 H01-O.16 <40 TSP ODSCC (1) 27 75 H02+ 0.05 <40 TSP ODSCC (1) 28 19 H01+15.99 <40 OD Indication (1) 28 21 H01+15.86 <40 OD Indication (1) 28 31 H01+16.19 <40 OD Indication (1) 2G 63 H02- 0.14 <40 TSP ODSCC (1) 28 67 Hol- 0.08 <40 TSP ODSCC

. (1) 28 69 H01+ 0.17 SAI TSP ODSCC Plug Tube 29 19 H01+15.98 <40 OD Indication (1) 29 27 H01+16.06 <40 OD Indication (1)

a M.

SEQUOYAH' NUCLEAR PIANT UNIT 2 CYCLE 6 INSPECTION q

AUGUST-1994 l

TABLE 3.4 1

LIST OF ' INDICATIONS ' AND TUBES PLUGGED l

(Continued)

SG 4 H2w Cql ' Location Characterization Resoluti'on Initial Sample (Continued) 29 67 AV1+ 0.00-14 -AVB Wear (2)

AV3+ 0.00 23 'AVB Wear (1)

)

I AV4+.0.00: 16 AVB Wear (2) 32 41 AV2+-0.00 14 AVB Wear (2).

AV3+.0.00 22 AVB Wear (1) 33 22' H01+15.84 <40 OD Indication (1) 35 55 AV1+'O.00 6

AVB Wear (2) 36 65 H01+ 0.00 <40 TSP ODSCC (1) 37 19 C01- 0.22 16 Cold Leg Wastage (2) 38 44 AV3+ 0.38 20 AVB Wear (1) 38 47 AV3+ 0.00 10 'AVB Wear (2)

AV4+ 0.00 10.AVB Wear.

(2) 38 49 AV3+ 0.00 7

AVB Wear.

(2) 38 52 AV3+ 0.00 18-AVB Wear (2) 43 35 CO2+ 0.16 21. Cold Leg Wastage (1) 43 61 CO2+ 0.00 31 Cold Leg Wastage (1)-

44

.61 C03+ 0.36 17 Cold Leg Wastage (2) 45 54-CO2+ 0.08 25 Cold Leg Wastage (1) 45 57 CO2+ 0.11 17 Cold Leg Wastage (2)

Steam Generator 4 Inspection Initial-Sample Results have been classified as Category C-2.

s 1

First Expansion Sample No indications Steam Generator 4 Inspection First Expansion. Sample Results have.

j

.been classified as Category C-1.

(1)

. Retest Future Outage (2) - None Required

=

s.

(

SEQUOYAH NUCLEAR PLANT UNIT 2 CYCLE 6 INSPECTION AUGUST 1994 l

Table 4 NOMENCLATURE Location Nomenclature for Sequoyah Nuclear Plant Notation Descrintion HTE Tube end - hot leg HTS Top of tubesheet - het leg Hol First support plate - hot leg H02 Second support plate - hot leg H03 Third support plate - hot leg H04 Fourth support plate - hot leg H05 Fifth support plate - hot leg H06 Sixth support plate - hot leg

}

H07 Seventh support plate - hot leg C07 Seventh support plate - cold leg C06 Sixth support plate - cold leg C05 Fifth support plate - cold leg C04 Fourth support plate - cold leg C03 Third support plate - cold leg CO2 Second support plate - cold leg Col First support plate - cold leg CTS Top of tubesheet - cold leg CTE Tube end - cold leg Indication locations are designated by the above list with a numeric value in inches above or below.

Positive inches indicate positive elevation.

Examples -

His+ 1.00 is one inch atnve the hot leg top of tubesheet.

H01+ 0.25 is one quarter inch above the center of the first hot leg tw support plate.

AVP Anti-Vibration Bar FLBD Flow Lane Blocking Device MFG.

Manufacturing ODSCC Outside Diameter Stress Corrosion Cracking PWSCC Primary Water Stress Corrosion Cracking SAI Single Axial Indication g

SCI Single Circumferential Indication TSP Tube Support Plate TTS Top-of-Tubesheet