- ML20083F934 + (ML20083F934)
- ML20083F935 + (ML20083F935)
- ML20083F940 + (ML20083F940)
- 3F1283-34, Forwards Response to NRC Re Violations Noted in IE Insp Rept 50-302/83-21.Corrective Action Withheld + (ML20083F946)
- ML20083F949 + (ML20083F949)
- ML20083F951 + (ML20083F951)
- 05000315/LER-1983-119-03, /03L-0:on 831123,reservoir & Half of Retaining Clamp for Snubber 1-GRC-S594 Found Detached from Snubber. Caused by Loosening of Clamp Fasteners & Vibration.New Snubber Tested & Installed + (ML20083F954)
- B10983, Advises That Weston Geophysical Corp Rept, Seismology & Geological Studies:Miramichi Area,New Brunswick & Central Nh No Longer Treated as Proprietary Info Due to Limited Commercial Marketability + (ML20083F955)
- ML20083F970 + (ML20083F970)
- NUREG-2233, EPRI 3002016054 Comments Resolution + (ML20083F972)
- ML20083F974 + (ML20083F974)
- 05000328/LER-1983-172-03, /03L-0:on 831130,steam Generator Blowdown Containment Isolation Valve 2-FCV-1-182 Failed to Close on Demand.Caused by Valve Limit Switch Misadjustment.Switch Adjusted & Returned to Svc on 831130 + (ML20083F980)
- U-101112, Interim Deficiency Rept 82-12 Re Binding of Sway Strut/ Snubber Piping Component Supports.Initially Reported on 821021.Defective Parts Tagged & Segregated to Prevent Inadvertent Use.Final Rept Will Be Submitted in 90 Days + (ML20083F991)
- ML20083F999 + (ML20083F999)
- ML20083G001 + (ML20083G001)
- ML20083G008 + (ML20083G008)
- ML20083G017 + (ML20083G017)
- ML20083G022 + (ML20083G022)
- RBG-16-650, Final Deficiency Rept DR-122 Re Filler Matl in Bf Shaw Shop Welds.Condition Not Reportable Under 10CFR50.55(e) + (ML20083G028)
- ML20083G037 + (ML20083G037)
- NRC-83-0064, Interim Significant Deficiency Rept 83-13 Re Limitorque Valve Operator Limit Switch Rotor Matl.Initially Reported 831116.Caused by Excessive Shrinkage in Matl in Rotors. Rotors Replaced.Also Reported Per Part 21 + (ML20083G038)
- ML20083G039 + (ML20083G039)
- ML20083G044 + (ML20083G044)
- ML20083G049 + (ML20083G049)
- ML20083G051 + (ML20083G051)
- ML20083G052 + (ML20083G052)
- ML20083G053 + (ML20083G053)
- ML20083G059 + (ML20083G059)
- ML20083G060 + (ML20083G060)
- ML20083G062 + (ML20083G062)
- ML20083G063 + (ML20083G063)
- ML20083G088 + (ML20083G088)
- AECM-84-0021, Endorses Safety Review Committee on Operational Readiness Review for 5% Power.Util Mgt Reviewed & Approved Rept W/One Exception Re Diesel Generator Testing.Exception Outlined in Encl + (ML20083G090)
- ML20083G092 + (ML20083G092)
- ML20083G093 + (ML20083G093)
- ML20083G101 + (ML20083G101)
- RBG-16-610, Interim Deficiency Rept DR-97 Re Hma Relays Mfg by GE in 1974.Next Rept Will Be Submitted by 840207 + (ML20083G102)
- ML20083G103 + (ML20083G103)
- ML20083G111 + (ML20083G111)
- ML20083G112 + (ML20083G112)
- ML20083G115 + (ML20083G115)
- ML20083G119 + (ML20083G119)
- ML20083G125 + (ML20083G125)
- ML20083G128 + (ML20083G128)
- 05000348/LER-1983-080-03, /03L-0:on 831125,spent Fuel Storage Area Radiation Monitor R-5 Declared Inoperable Due to Erroneous Indication. Caused by Loose Connection.Connection Repaired + (ML20083G132)
- ML20083G133 + (ML20083G133)
- ML20083G134 + (ML20083G134)
- ML20083G137 + (ML20083G137)
- ML20083G138 + (ML20083G138)
- 05000369/LER-1983-113-03, /03L-0:on 831124,trouble Alarm for Fire Detection Zone Efa 162 Received & Would Not Reset.Caused by Moisture Accumulation in Detector Base,Resulting in Corrosion.Water Source Undetermined.Detector Replaced + (ML20083G141)
- 05000348/LER-1983-081-03, /03L-0:on 831201,river Water Pump 4 Declared Inoperable Due to Broken Lower Pump Bearing Lube Water Supply Line.Caused by Failed Fitting Between Line & Pump. Fitting Replaced + (ML20083G145)