- ML20083D774 + (ML20083D774)
- 05000370/LER-1983-073-03, /03L-0:on 831026,main Steam PORVs 2SV-1,7,13 & 19 Did Not Receive Close Signal from Solid State Protection Sys Train A.Caused by Disconnected Wire.Wire Reconnected + (ML20083D776)
- 05000250/LER-1983-022-03, /03L-0:on 831002,during Scheduled Refueling Shutdown Operations,Motor Operated Valves 843A,843B & 869 Not Verified Closed W/Breakers Racked Out.Caused by Not Adhering to Procedures + (ML20083D782)
- ML20083D784 + (ML20083D784)
- ML20083D785 + (ML20083D785)
- 05000327/LER-1983-174-03, /03L-0:on 831121,ESF for Steam Line Pressure Function Failed to Meet Surveillance Requirements & Declared Inoperable.Caused by Dirty Contacts on Universal Logic Card A206 + (ML20083D788)
- 05000482/LER-1991-011, :on on 910718,determined That Quarterly CCW Inservice Valve Test Not Completely Performed on 910514. Caused by Status Sheet Incorrectly Initialed to Signify Test Completed.Individual Counseled + (ML20083D794)
- ML20083D797 + (ML20083D797)
- ML20083D800 + (ML20083D800)
- ML20083D802 + (ML20083D802)
- ML20083D813 + (ML20083D813)
- 05000296/LER-1983-059-01, /01T-0:on 831208,during Refueling outage,crack- Like Indication Detected.Caused by Intergranular Stress Corrosion Cracking on Weld DSHS-3-2.Head Spray Piping Will Be Removed Before Startup + (ML20083D814)
- ML20083D816 + (ML20083D816)
- RBG-35-679, Forwards Results of UT Conducted on N4A-2 Feedwater Nozzle to safe-end Weld During mid-cycle Outage of Fourth Fuel Cycle.Circumferential Indication in Buttered Area of Safe End Side of Weld Noted During Second Refueling Outage + (ML20083D819)
- 05000321/LER-1983-112-03, /03L-0:on 831117,two Vacuum Breakers Would Not Open & Close Properly.Caused by Inadequate Design of Vacuum Breaker Hinge Pin.Safety Relief Valve Discharge Line Vacuum Breakers Replaced + (ML20083D821)
- ML20083D822 + (ML20083D822)
- ML20083D827 + (ML20083D827)
- TXX-9128, Supplemental Deficiency Rept CP-85-054 Re Discrepancies in Seismic Qualification Documents for HVAC Supports.Design Basis Document Established to Ensure That Seismic Qualification Requirements Maintained + (ML20083D834)
- ML20083D835 + (ML20083D835)
- ML20083D840 + (ML20083D840)
- RBG-16-594, Forwards Description of ASME III Subsection Nf Support Program Per 831213 Telcon.Info Will Be Included in Future FSAR Amend + (ML20083D842)
- ML20083D844 + (ML20083D844)
- 05000456/LER-1991-009-04, :on 910805,gas Decay Tank Sample Not Obtained. Caused by Procedure Deficiency.Alarm Response & Operating Procedures Will Be Revised to Provide More Guidance.W/ + (ML20083D845)
- 05000280/LER-1983-052-03, /03L-0:on 831118,both Charging Pump Component Cooling Water Intermediate Seal Coolers Isolated.Caused by Inadvertent Isolation of Cooler A.Component Cooling Water to Coolers Unisolated + (ML20083D851)
- ML20083D855 + (ML20083D855)
- ML20083D856 + (ML20083D856)
- 05000457/LER-1991-004-10, :on 910823,late Performance of Tech Spec Surveillance Occurred.Caused by Personnel Error.Corrective Actions:Gsrv Logbook Will Be Updated Using Date Directly from Surveillance Cover Sheet + (ML20083D859)
- ML20083D860 + (ML20083D860)
- ML20083D862 + (ML20083D862)
- 05000259/LER-1991-009-02, :on 910824,fire Penetration Discovered Open W/O Fire Watch in Place as Required by Plant Tech Specs. Caused by Inappropriate Personnel Action.Personnel Will Be Trained on Event + (ML20083D863)
- ML20083D869 + (ML20083D869)
- ML20083D870 + (ML20083D870)
- ML20083D872 + (ML20083D872)
- NRC-91-0119, Application for Amend to License NPF-43,changing Tech Specs to Revise Instrumentation Setpoints for Rod Block Monitor Downscale Trip Function + (ML20083D875)
- ML20083D877 + (ML20083D877)
- ML20083D878 + (ML20083D878)
- ML20083D880 + (ML20083D880)
- ML20083D884 + (ML20083D884)
- ML20083D885 + (ML20083D885)
- ML20083D888 + (ML20083D888)
- ML20083D903 + (ML20083D903)
- ML20083D906 + (ML20083D906)
- ST-HL-AE-1035, Final Deficiency Rept DER-019 Re Potentially Overstressed Containment Mechanical Penetration Welds.Initially Reported on 831115.Penetration Assemblies Modified by Replacing Carbon Steel Plate W/Stainless Steel Plate + (ML20083D914)
- ML20083D917 + (ML20083D917)
- 05000285/LER-1983-012-03, /03L-0:on 831122,during Performance of Monthly Surveillance Test,Pressure Indicator D/Pic-905 Operated Erratically.Caused by Blown Power Supply Fuse.Fuse Replaced + (ML20083D918)
- ML20083D919 + (ML20083D919)
- ST-HL-AE-1031, Forwards Response to Generic Ltr 81-07, Control of Heavy Loads. Deviations from Established Load Paths Will Require Written Alternatives Approved by Plant Safety Review Committee + (ML20083D922)
- ML20083D924 + (ML20083D924)
- ML20083D936 + (ML20083D936)
- ML20083D938 + (ML20083D938)
- ML20083D942 + (ML20083D942)