Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- LIC-95-0079, Responds to Questions in NRC 950302 RAI & Addl Questions Raised by NRC During 950323 Telcon,To Assist Closure of NRR Review of Plant Revised Evaluation of Control Habitability + (ML20082J225)
- ML20082J237 + (ML20082J237)
- ML20082J249 + (ML20082J249)
- ML20082J260 + (ML20082J260)
- ML20082J265 + (ML20082J265)
- ML20082J266 + (ML20082J266)
- ML20082J276 + (ML20082J276)
- LIC-95-0084, Informs That Util Completed eddy-current Testing of SG Tubes at Plant on 950317,during Fifteenth Refueling Outage + (ML20082J278)
- 05000373/LER-1983-127-03, /03L-0:on 831031,rod Block Monitor Channel a Generated Erratic & False Meter Indications for Local Power Range Monitor a & C Levels.Caused by Oscillations from Failed Capacitor.Capacitor Module Replaced + (ML20082J289)
- 05000373/LER-1983-125-03, /03L-0:on 831021,during Control Rod Movements,Rod Block Monitor Channel a Declared Inoperable & Rod Block Alarms Sounded When Control Rod Selected.Caused by Failed Logic Card.Card Replaced + (ML20082J291)
- ML20082J294 + (ML20082J294)
- ML20082J296 + (ML20082J296)
- 05000373/LER-1983-130-03, /03L-0:on 831021,stack wide-range Gas Monitor Alarm Received.Caused by Checksource Not Remaining Long Enough at Detector Window for Detector to respond.Mid-range Detector Manually Source Checked + (ML20082J298)
- ML20082J303 + (ML20082J303)
- ML20082J307 + (ML20082J307)
- ML20082J309 + (ML20082J309)
- 05000306/LER-1983-026-03, /03L-0:on 831021,sodium Hydroxide Concentration of 11.5% in Spray Additive Tank Exceeded Tech Spec Limit of 11%.Caused by Inadequate Mixing for Design Change.Tank Refilled.Solution Diluted & Recirculated + (ML20082J316)
- ML20082J317 + (ML20082J317)
- 05000373/LER-1983-131-03, /03L-0:on 831019,reactor Recirculation Sys Jet Pumps Did Not Meet Tech Spec Operability Criteria.Caused by Use of Data Obtained from Test Condition 3 Rather than Test Condition 6.Pumps Retested W/Proper Data + (ML20082J318)
- ML20082J323 + (ML20082J323)
- ML20082J325 + (ML20082J325)
- ML20082J331 + (ML20082J331)
- 05000249/LER-1983-040-03, /03L-0:on 831028,diesel Generator Did Not Close Onto 4-kV Bus 34-1 & Feed Breaker Remained Tripped.Caused by Dirt Buildup on Contact 52H on Bus.Contact Burnished + (ML20082J334)
- ML20082J336 + (ML20082J336)
- NG-83-3907, Responds to IE Bulletin 83-06 Re Tube-Line Corp Supplies. Documentation Review Revealed Tube-Line Products Not Received at Plant + (ML20082J339)
- ML20082J340 + (ML20082J340)
- ML20082J347 + (ML20082J347)
- PY-CEI-NRR-0082, Responds to IE Bulletin 83-06 Re Nonconforming Matls Supplied by Tube-Line Corp.Facility Does Not Possess Any Tube-Line Matl Described in Bulletin + (ML20082J349)
- ML20082J353 + (ML20082J353)
- 05000263/LER-1983-023-03, /03L-0:on 831026,flow Through Train B Standby Gas Treatment Less than Tech Spec Requirement.Caused by Stack Exhaust Flow Incorrectly Adjusted.Stack Flow Corrected + (ML20082J363)
- ML20082J368 + (ML20082J368)
- ML20082J372 + (ML20082J372)
- ML20082J374 + (ML20082J374)
- ML20082J378 + (ML20082J378)
- ML20082J384 + (ML20082J384)
- ML20082J385 + (ML20082J385)
- 05000373/LER-1983-132-03, /03L-0:on 831020,HPCS Diesel Air Start Storage Tank Air Pressure Dropped Below Tech Specs & Declared Inoperable.Caused by Air Compressor Failure Due to first- Stage Relief Valve Lifting.Compressor Repaired + (ML20082J390)
- ML20082J397 + (ML20082J397)
- ML20082J400 + (ML20082J400)
- ML20082J407 + (ML20082J407)
- ML20082J413 + (ML20082J413)
- ML20082J422 + (ML20082J422)
- ML20082J423 + (ML20082J423)
- ML20082J426 + (ML20082J426)
- ML20082J441 + (ML20082J441)
- ML20082J445 + (ML20082J445)
- ML20082J456 + (ML20082J456)
- ML20082J459 + (ML20082J459)
- ML20082J470 + (ML20082J470)
- ML20082J474 + (ML20082J474)
- ML20082J483 + (ML20082J483)