- ML20076F335 + (ML20076F335)
- 3F1094-07, Special Rept:On 940919,determined That Two Transmitters Which Comprise Rv Level Indication Sys Portion of Rc Inventory Tracking Sys Not Functioning Normally Due to Line Blockage in Common Tubing.Sys Restoration outage-dependent + (ML20076F337)
- ML20076F338 + (ML20076F338)
- 05000361/LER-1983-045-03, /03L-0:on 830504,while Working on Plant Protection Sys Channel A,Reactor Trip Circuit Breaker TCB-1 Tripped Open,Rendering Channel Inoperable.Caused by Loose Cable Terminal Block Screws.Screws Tightened + (ML20076F339)
- 05000362/LER-1994-002-01, :on 940912,momentary Loss of Voltage on Class 1E 4 Kv Bus 3A06 & Loss of Voltage Signal Occurred Due to Jarring of door-mounted Protective Relay.Normal Power to Bus 3A06 Restored within 72 H Allowed by TS + (ML20076F340)
- 05000277/LER-1994-008-02, :on 940909,discovered That ECCS & EDG May Have Been TS Inoperable on 940803 When ESW Outlet Valve MO-0498 Closed & Left Unattended,Causing ECT to Overflow.Valve Opened & ECT Level Restored to Normal Range.W/Undated Ltr + (ML20076F342)
- ML20076F344 + (ML20076F344)
- L-83-202, Responds to IE Bulletin 83-04, Failure of Under Voltage Trip Function of Reactor Trip Breakers. Representatives from Util & GE Are Testing Performance of Breakers Per Electrical Maint Procedure 0110060 + (ML20076F345)
- ML20076F346 + (ML20076F346)
- ML20076F349 + (ML20076F349)
- ML20076F350 + (ML20076F350)
- ML20076F355 + (ML20076F355)
- 05000454/LER-1994-009-07, :on 940908,reactor Trips Occurred During Planned Shutdown Due to Solid State Protection Sys Failure. Caused by Personnel Error.Event Placed in Required Reading for Sys Engineering Dept + (ML20076F356)
- ML20076F357 + (ML20076F357)
- ML20076F360 + (ML20076F360)
- 05000361/LER-1983-049-03, /03L-0:on 830429,emergency Chiller E-336 (Train a) Failed to Start Following Invalid Tgis.Caused by Misalignment of Supply Breaker.Breaker Aligned + (ML20076F365)
- ML20076F368 + (ML20076F368)
- ML20076F369 + (ML20076F369)
- 05000416/LER-1983-021-01, /01T-0:on 830519,while in Cold Shutdown,Standby Gas Treatment Sys Flow Monitoring Instrumentation Found Reading in Error.Caused by Incorrect Calibr Range.Correct Calibr Ranges Issued + (ML20076F375)
- ML20076F376 + (ML20076F376)
- 0CAN068304, Responds to IE Bulletin 83-03, Check Valve Failures in Raw Water Cooling Sys of Diesel Generators. Check Valves Described in Bulletin Not Employed at Facilities.Bulletin Not Applicable + (ML20076F380)
- ML20076F383 + (ML20076F383)
- ML20076F393 + (ML20076F393)
- ML20076F395 + (ML20076F395)
- ML20076F399 + (ML20076F399)
- ML20076F405 + (ML20076F405)
- ML20076F406 + (ML20076F406)
- ML20076F410 + (ML20076F410)
- 05000395/LER-1983-044-01, /01T-0:on 830523,steam Generator B Feedwater Flow Transmitter FT-486 Did Not Respond to Change in Feedwater Flow.Caused by Personnel Error in Not Properly Identifying Transmitter on Tagout Sheet + (ML20076F412)
- ML20076F416 + (ML20076F416)
- ML20076F422 + (ML20076F422)
- L-83-340, Responds to IE Bulletin 79-14, Seismic Analysis for As- Built Safety-Related Piping Sys. Program Verifying Piping Geometry,Including Support/Restraint/Valve Locations Re Piping Sys & Restraint Function,Complete + (ML20076F425)
- L-94-030, Monthly Operating Repts for Sept 1994 for Point Beach Nuclear Plant + (ML20076F429)
- ML20076F440 + (ML20076F440)
- ML20076F443 + (ML20076F443)
- JPN-94-051, Forwards Application for Amend to License DPR-59,changing TS Re Safety/Relief Valve Testing Requirements + (ML20076F450)
- 1CAN088309, Provides Current Status of Dresser Safety Valve Settings. Valve Settings Are -48,-93,+5 & W/No Lift Restriction. Adjustments Assure Safety Valves Will Achieve 100% of ASME Rated Capacity + (ML20076F451)
- 05000260/LER-1983-041-03, /03L-0:on 830721,following Preconditioning Operations,Tech Spec Limit for Linear Heat Generation Rate Exceeded in Four Nodes.Caused by Insufficient Communication Between Operators During Flow Increases + (ML20076F453)
- ML20076F454 + (ML20076F454)
- AECM-83-0477, RO 83-070/0:on 830716,listed Fire Rated Doors Blocked Open to Support Planned Maint Activities in Auxiliary & Control Bldgs.Fire Watches Established.Doors Expected to Be Restored by 830930 + (ML20076F455)
- ML20076F458 + (ML20076F458)
- ML20076F459 + (ML20076F459)
- ML20076F461 + (ML20076F461)
- ML20076F462 + (ML20076F462)
- ML20076F463 + (ML20076F463)
- W3P83-2783, Forwards Vital Equipment Block Diagram,Per 830725 Request. Diagram Withheld + (ML20076F464)
- IR 05000346/2020301 + (ML20076F465)
- 05000331/LER-1983-027-03, /03L-0:on 830803,RCIC Discharge Pressure Indicator Found Indicating Improperly.Caused by out-of-calibr Pressure Transmitter.Transmitter Calibr + (ML20076F466)
- ML20076F468 + (ML20076F468)
- ML20076F470 + (ML20076F470)
- ML20076F473 + (ML20076F473)