Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- 2CAN088314, Forwards Proprietary IAEA Design Info Questionnaire & Matl Balance Rept for Apr-Jul 1983.Installation Info to Be Transmitted to IAEA for Use in Safeguards Insp of Facility, Per .Encl Withheld + (ML20076E997)
- ML20076E999 + (ML20076E999)
- ML20076F000 + (ML20076F000)
- 05000387/LER-1983-104-03, /03L-0:on 830717,emergency Outside Air Intake High Radiation Alarm Received in Main Control Room.Caused by One Channel Detector Drifted High Due to Failure of Gm Tube. Gm Tube Replaced,Calibr & Retested + (ML20076F001)
- ML20076F002 + (ML20076F002)
- ML20076F005 + (ML20076F005)
- ML20076F011 + (ML20076F011)
- ML20076F012 + (ML20076F012)
- ML20076F016 + (ML20076F016)
- AECM-83-0486, Forwards Negotiated Schedule for Emergency Response capability.NUREG-0737,Suppl 1 Sections & 830413 Proposed Integrated Schedule Task Descriptions Referenced to Clarify Actions to Be Performed + (ML20076F017)
- ML20076F020 + (ML20076F020)
- 05000293/LER-1981-059-03, Acceptance Criteria for Test 8.7.3,Secondary Containment Leak Rate Test, Not Met. Caused by Damper Alignment Reducing Capability.Engineering Evaluations Added to Procedure + (ML20076F021)
- ML20076F022 + (ML20076F022)
- BSEP-83-1618, Ro:On 830509,main Condenser Steam Jet Air Ejector Offgas Radiation Monitors a & B Failed to Indicate Power Level. Caused by Closure of Root Isolation Valves to Each Monitor. Shift Personnel Counseled + (ML20076F026)
- ML20076F027 + (ML20076F027)
- ML20076F028 + (ML20076F028)
- ML20076F029 + (ML20076F029)
- ML20076F030 + (ML20076F030)
- ML20076F032 + (ML20076F032)
- ML20076F033 + (ML20076F033)
- ML20076F036 + (ML20076F036)
- ML20076F041 + (ML20076F041)
- TXX-3674, Forwards,For Review,Revised Page from Chapter 17.1 of Fsar.Change (Amend 40) Adds More Specific Commitment Re QA Program,Per Encl NRC 830307 Request + (ML20076F042)
- RBG-15-116, Interim Deficiency Rept DR-73 Re Improperly Installed Spring Nuts in GE Power Generation Control Complex Termination Cabinets.Initially Reported on 820902.GE Evaluation Awaited.Next Rept Due by 830805 + (ML20076F048)
- ML20076F049 + (ML20076F049)
- ML20076F052 + (ML20076F052)
- ML20076F055 + (ML20076F055)
- 05000327/LER-1983-057-03, /03L-0:on 830426,subcooling Margin Monitor Declared Inoperable Due to Plant Process Computer Failure. Caused by Power Failure.Computer Supplied by Maint Power While Inverter Repaired + (ML20076F058)
- ML20076F059 + (ML20076F059)
- ML20076F064 + (ML20076F064)
- 05000369/LER-1983-020-01, /01T-0:on 830503,soap Bubble Test of 47 Secondary Containment Bypass Leakage Paths Not Performed During Initial Integrated Leak Rate Test.Caused by Procedural Deficiency.Procedures Revised + (ML20076F065)
- ML20076F071 + (ML20076F071)
- ML20076F073 + (ML20076F073)
- ML20076F074 + (ML20076F074)
- ML20076F076 + (ML20076F076)
- ML20076F080 + (ML20076F080)
- ML20076F088 + (ML20076F088)
- ML20076F089 + (ML20076F089)
- ML20076F093 + (ML20076F093)
- ML20076F099 + (ML20076F099)
- RBG-40915, Addresses Question Raised by NRC During 940928 Telcon Re 940912 Submittal of LAR 94-10,changing TS 3/4.2.2, APRM Setpoints + (ML20076F100)
- ML20076F101 + (ML20076F101)
- ML20076F103 + (ML20076F103)
- NG-94-3444, Forwards Revised FFD Program Performance Info for DAEC for Jan-June 1994,reflecting Correction Made to Synopsis on Attachment + (ML20076F105)
- ML20076F108 + (ML20076F108)
- ML20076F109 + (ML20076F109)
- RBG-15-117, Interim Deficiency Rept DR-101 Re Undersized Fillet Welds on Nf Pipe Supports.Initially Reported on 830223.Addl Info from Util Ae Awaited.Next Rept Will Be Submitted by 830808 + (ML20076F111)
- LIC-94-0193, Forwards Util Annual Audit for Period of Jul 1993 - June 1994,as Required by Decommissioning Funding Plan Trust Agreement Submitted W/Util + (ML20076F113)
- ML20076F114 + (ML20076F114)
- ML20076F115 + (ML20076F115)
- ML20076F116 + (ML20076F116)