- 05000321/LER-1979-021, Forwards Supplemental Narrative Summary to LER-79-021/03L-0, Rev 5 Re Tritium Levels in Groundwater for Second Quarter 1983 Exceeding ETS Levels + (ML20076B502)
- ML20076B505 + (ML20076B505)
- ML20076B508 + (ML20076B508)
- ML20076B509 + (ML20076B509)
- 05000416/LER-1983-068-01, While in Cold Shutdown, Discrepancy Identified Between Tech Specs & FSAR Re Secondary Containment Ventilation Isolation Damper Closure Time.Cause Unknown + (ML20076B513)
- ML20076B518 + (ML20076B518)
- 05000369/LER-1983-053-03, /03L-0:on 830701,quadrant Power Tilt Ratio Exceeded Tech Spec Limits During Startup Power Increase. Caused by in-core Xenon Imbalance of Unknown Origin.Neutron Flux Increased,Eliminating Xenon by Burnup + (ML20076B521)
- PMNS20200261, Closed Public Meeting to Discuss NEI 09-05 Unattended Opening + (ML20076B522)
- 05000327/LER-1983-090-03, /03L-0:on 830714,w/Unit 1 in Mode 1 & Unit 2 in Mode 1,while Performing SMI-1-SD1B-5,6,900-volt Shutdown Board 1B-B Deenergized.Caused by Personnel Failure to Reset Device 86S1B Before Replacing Trip Cut Blocks + (ML20076B524)
- ML20076B527 + (ML20076B527)
- ML20076B528 + (ML20076B528)
- ML20076B541 + (ML20076B541)
- 05000352/LER-1991-014, :on 910530,failed to Perform Tech Spec SR for Tech Spec 3.7.7, Fire Rated Assemblies. Caused by Personnel Error Resulting in Procedural Deficiencies. Surveillance Test Requirements Will Be Revised + (ML20076B544)
- 05000334/LER-1991-018, :on 910606,auxiliary Feedwater Pump Flow Indicating Switches as-found Configuration Not Supported by Seismic Analysis.Caused by Installation as Part of Design Change in 1980.Design Change Initiated + (ML20076B550)
- 05000325/LER-1983-029-03, /03L-0:on 830713,during Exchange of Hoses in Radwaste Bldg,Nozzle on Hose Station RW-51 Found Missing & Hose Found Charged W/Water.Cause Undetermined.Frequency of Hose Insps Increased + (ML20076B563)
- 05000302/LER-1983-026-03, /03L-0:on 830712,erroneous Shutdown Margin Calculations Made Due to Procedure Inadequacies & Calculational Error.Caused by Personnel Error.Mgt Instruction Issued Revising Training Methods + (ML20076B565)
- 05000324/LER-1983-065-03, /03L-0:on 830714,HPCI Condensate Storage Tank Level Switches E41-LSL-N002 & N003 Found W/Float Setpoint Out of Calibr.Caused by Incorrectly Installed Level Switches.Level Switches Raised to Proper Level + (ML20076B573)
- ML20076B575 + (ML20076B575)
- ML20076B576 + (ML20076B576)
- 05000416/LER-1983-099-03, /03L-0:on 830714,while Performing 18-month Channel Calibr,Suppression Pool Low Water Level Channel a Trip Found Out of Tech Spec Limit.Caused by Instrument Drift.Rosemount Model 510DU245011 Reset + (ML20076B577)
- ML20076B579 + (ML20076B579)
- ML20076B589 + (ML20076B589)
- ML20076B590 + (ML20076B590)
- ML20076B594 + (ML20076B594)
- ML20076B597 + (ML20076B597)
- ML20076B606 + (ML20076B606)
- ML20076B607 + (ML20076B607)
- 05000260/LER-1983-039-03, /03L-0:on 830716,during Transient Operation, Following Control Rod Sequence Exchange & Scram Testing, Program P1 Indicated R Calculated Less than R Setpoint. Caused by Failure of TIP Machine Indexer D + (ML20076B609)
- ML20076B612 + (ML20076B612)
- 05000315/LER-1983-066-03, /03L-0:on 830711,leak Developed from Packing Seal Water Supply Line of Component Cooling Water Pump.Caused by Failure of 3/8-inch Isolation Valve on Supply Lines.Lines Removed & Pipe Plugs Installed + (ML20076B614)
- ML20076B619 + (ML20076B619)
- ML20076B622 + (ML20076B622)
- ML20076B623 + (ML20076B623)
- ML20076B627 + (ML20076B627)
- ML20076B629 + (ML20076B629)
- 05000315/LER-1983-067-03, /03L-0:on 830712,circuit Breaker for Containment Equalization Fan HV-CEQ-1 Tripped.Cause Not Determined. Breaker Replaced + (ML20076B630)
- ML20076B632 + (ML20076B632)
- ML20076B634 + (ML20076B634)
- ML20076B635 + (ML20076B635)
- ML20076B638 + (ML20076B638)
- ML20076B645 + (ML20076B645)
- ML20076B646 + (ML20076B646)
- ML20076B649 + (ML20076B649)
- ML20076B651 + (ML20076B651)
- 05000249/LER-1983-027-03, /03L-0:on 830714,rod Block Monitor Channel 7 Downscale Trip Level Setting Determined to Be 4.6/125 Full Scale & Below Tech Spec Limit.Caused by Electronic Drift of Channel 7.Setpoint Adjusted + (ML20076B655)
- ML20076B656 + (ML20076B656)
- ML20076B660 + (ML20076B660)
- 05000369/LER-1983-054-03, /03L-0:on 830701,two Programmed Setpoint Circuit Cards of Each Steam Generator Water Level low-low Channel Not Tested During Required Monthly Surveillance.Caused by Procedural Deficiency.Surveillance Procedure Revised + (ML20076B667)
- ML20076B670 + (ML20076B670)
- 05000369/LER-1983-033-03, /03L-0:on 830701,two Programmed Setpoint Circuit Cards of Each Steam Generator Water Level low-low Channel Not Tested During Required Monthly Surveillance.Cause Not Known.Monthly Surveillance Procedure Revised + (ML20076B675)
- ML20076B679 + (ML20076B679)