- ML20073S394 + (ML20073S394)
- 05000237/LER-1983-023, Forwards LER 83-023/03L-0 + (ML20073S397)
- ML20073S400 + (ML20073S400)
- ML20073S406 + (ML20073S406)
- 05000237/LER-1983-023-03, /03L-0:on 830406,during Surveillance of Component Cooling Svc Water Vault Floor Drain (DOS 4400-1),condensate Pump Room Flood Switch Actuated & Drain Valve AO-2-4999-74 Failed to Close.Cause Undetermined.Investigation Underw + (ML20073S409)
- ML20073S415 + (ML20073S415)
- ML20073S419 + (ML20073S419)
- ML20073S421 + (ML20073S421)
- ML20073S426 + (ML20073S426)
- ML20073S427 + (ML20073S427)
- ML20073S431 + (ML20073S431)
- ML20073S433 + (ML20073S433)
- ML20073S437 + (ML20073S437)
- ML20073S440 + (ML20073S440)
- ML20073S444 + (ML20073S444)
- ML20073S459 + (ML20073S459)
- ML20073S461 + (ML20073S461)
- ML20073S462 + (ML20073S462)
- ML20073S465 + (ML20073S465)
- ML20073S468 + (ML20073S468)
- ML20073S472 + (ML20073S472)
- ML20073S479 + (ML20073S479)
- ML20073S480 + (ML20073S480)
- ML20073S483 + (ML20073S483)
- ML20073S490 + (ML20073S490)
- ML20073S491 + (ML20073S491)
- ML20073S493 + (ML20073S493)
- ML20073S494 + (ML20073S494)
- ML20073S495 + (ML20073S495)
- ML20073S500 + (ML20073S500)
- ML20073S501 + (ML20073S501)
- ML20073S508 + (ML20073S508)
- ML20073S520 + (ML20073S520)
- ML20073S535 + (ML20073S535)
- ML20073S542 + (ML20073S542)
- ML20073S569 + (ML20073S569)
- ML20073S585 + (ML20073S585)
- ML20073S610 + (ML20073S610)
- ML20073S619 + (ML20073S619)
- ML20073S628 + (ML20073S628)
- ML20073S639 + (ML20073S639)
- ML20073S648 + (ML20073S648)
- 05000369/LER-1983-016, Forwards LER 83-016/03L-0 + (ML20073S651)
- 05000369/LER-1983-016-03, /03L-0:on 830327,hanger 1MCA-ND-H260 Discovered Pulled Loose from Wall Anchors & Snubbers 1MCA-ND-H177 & H317 Found Locked Up During Subsequent full-stroking.Caused by Water Hammer Event Resulting in Void Formation + (ML20073S654)
- ML20073S657 + (ML20073S657)
- ML20073S661 + (ML20073S661)
- 05000348/LER-1983-016, Forwards LER 83-016/03L-0 + (ML20073S662)
- 05000348/LER-1983-016-03, /03L-0:on 830412,diesel Generator 1B Declared Inoperable Due to Start Failure Resulting in Inoperability of Train B Due to Loss of Emergency Power.Caused by Mechanical Binding of Fuel Filter Constant Vent Check Valve + (ML20073S665)
- ML20073S666 + (ML20073S666)
- 05000259/LER-1980-049, Forwards Updated LER 80-049/03X-1 + (ML20073S668)
- 05000259/LER-1980-049-03, Increase in Pressure Detected on Shell Side of RHR 1-C Hx.Caused by Loose Locking & Full Nuts on Floating Head Due to Thermal Cycling & Vibration.Locking Tabs Installed on Nuts + (ML20073S671)