- 05000259/LER-1983-015-03, /03L-0:on 830310,temp Switch TS-71-2L Operated at 2049F,exceeding Tech Spec Requirements.Caused by Temp Switch Calibr Drift.Switch Replaced,Functionally Tested & Returned to Svc + (ML20073D402)
- 05000254/LER-1994-008-07, :on 940820,unit 1 Reactor Was Manually Scrammed by Procedure to Achieve Shutdown Condition Required by Tss. Caused by Work Practices Associated W/Crimping Terminal Lug. Wire Terminal Lugs Were Replaced W/New Parts + (ML20073D403)
- ML20073D404 + (ML20073D404)
- ML20073D405 + (ML20073D405)
- ML20073D408 + (ML20073D408)
- ML20073D409 + (ML20073D409)
- ML20073D411 + (ML20073D411)
- 05000296/LER-1983-019-03, /03L-0:on 830312,while Performing Surveillance Instruction SI 4.3.C (Scram Timing),Control Rod Drive 38-31 Failed to Scram Upon Signal.Caused by O-ring on Valve Out of Position.Valve Rebuilt + (ML20073D413)
- ML20073D418 + (ML20073D418)
- ML20073D422 + (ML20073D422)
- 05000348/LER-1994-004, :on 940602,valve Actuator Spacer Bolts Found to Be of Incorrect Matl.Bolts of Correct Matl Installed in Actuator & Turbine Steam Admission Valve + (ML20073D424)
- ML20073D425 + (ML20073D425)
- ML20073D427 + (ML20073D427)
- ML20073D430 + (ML20073D430)
- ML20073D431 + (ML20073D431)
- ML20073D432 + (ML20073D432)
- ML20073D433 + (ML20073D433)
- ML20073D436 + (ML20073D436)
- 05000335/LER-1983-018-03, /03L-0:on 830309,during Local Leak Rate Testing, Valve FCV-25-3 Leaked Excessively & Check Valves V-27101 & V-27102 Stuck Open.Caused by Dirt Preventing Closure. Valves Adjusted & Cleaned + (ML20073D437)
- ML20073D439 + (ML20073D439)
- RC-94-0251, Provides 10CFR50.46 30 Day Rept,Documenting Changes to Current ECCS Evaluation Model Due to Boiling Heat Transfer Correlation Errors,Steam Line Isolation Logic Errors & Core Node Zirc Oxide Initialization Error + (ML20073D440)
- ML20073D441 + (ML20073D441)
- ML20073D445 + (ML20073D445)
- ML20073D446 + (ML20073D446)
- ML20073D450 + (ML20073D450)
- ML20073D456 + (ML20073D456)
- PY-CEI-NRR-1861, Submits Addl Info to Answer Questions Raised During NRC Review of Util 930311 & 1221 Responses to NRC Bulletin 90-001,Suppl 1 + (ML20073D459)
- ML20073D460 + (ML20073D460)
- ML20073D462 + (ML20073D462)
- ML20073D463 + (ML20073D463)
- RC-94-0247, Forwards Amend 94-02 to Updated Fire Evaluation Rept for VC Summer Nuclear Station + (ML20073D464)
- ML20073D492 + (ML20073D492)
- ML20073D501 + (ML20073D501)
- ML20073D502 + (ML20073D502)
- U-601825, 1990 Annual Radiological Environ Monitoring Rept + (ML20073D506)
- ML20073D515 + (ML20073D515)
- ML20073D526 + (ML20073D526)
- ML20073D529 + (ML20073D529)
- ML20073D542 + (ML20073D542)
- ML20073D547 + (ML20073D547)
- HL-4700, Forwards Revised LER Re Main Steam Line High Flow Isolation Setpoint Not within TS Limits.Due Apparent Error in Distribution of Original Ler,Incomplete Rept Mailed + (ML20073D572)
- ML20073D576 + (ML20073D576)
- ML20073D577 + (ML20073D577)
- ML20073D586 + (ML20073D586)
- 05000321/LER-1994-009, :on 940728,determined That High Flow Isolation Setpoint for Main Steam Line Flow Instruments Not within TS Limits Due to Personnel Error.Setpoint Recalculated Based on Rated Flow & Setpoint for Flow Instruments Adjusted + (ML20073D591)
- ML20073D600 + (ML20073D600)
- ML20073D603 + (ML20073D603)
- L-94-029, Forwards Public & Central Files Versions of Revised Epips. Central Files Version of Revised EPIPs Withheld + (ML20073D615)
- ML20073D622 + (ML20073D622)
- ML20073D628 + (ML20073D628)
- ML20073D629 + (ML20073D629)