p Dube1%werCornpany D. L Rtm Catawba Nuclear Generation Depamnent Vice President 4800 ConcordRoad (803)8313205 Once York.SC29745 (803)S313426 Far

' DUKEPOWER L..

September 19,1994 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington,DC 20555

Subject:

Catawba Nuclear Station, Unit 2 Docket No. 50-414 Unit 2 Refueling Outage 6 1994 Inservice Inspection Repon Pursuant to 10 CFR 50.55a and Catawba Nuclear Station Technical Specification 4.0.5, find attached the Catawba Unit 2 End of Cycle 6 Insenice Inspection Report. The Catawba Unit 2 End of Cycle 6 Inservice Inspection was completed on June 30, 1994. This inspection was perfbnned in accordance with Section XI of the ASME Boiler and Pressure Vessel Code and applicable addenda-Relief Reque!,194-02 is included as Section 9 in this submittal. This formal relief request, with

- supponing documentation will be submitted under separate cover by L. J. Rudy.

Questions concerning this submittal may be directed to K. E. Nicholson at (803) 831-3237.

Veiy truly you,

D. L. Rehn

- KEN /EOC61SI.U2 Attachment xc: (w/o attachment)

S. D. Ebneter, Regional Administrator R. J. Freudenberger, SRI R. E. Martin, ONRR 230056 9409270209 940919 of I

PDR ADOCK 05000414 y,I CJ PDR e %ena.

I' 320 Pages FORM NIS-1 OWNERS' DATA REPP"T FOR INSERVICE INSPECTIONS As required by the Prov'

'as of the ASME Code Rules 1.

Owner:

Duke Power Company. 526 S. Church St.. Charlotte. NC 28201-1006 (Name and Address of Owner) 2.

Plant: Catawba Nuclear Station. 4800 Concord Road York. SC 29745 (Name and Address of Plant) 3.

Plant Unit: 2 4.

Owner Certificate of Authorization (if required) N/A 5.

Commercial Service Date: August 19.1986 6. National Board Number for Unit 1Z3 7.

Components Inspected:

Component or Manufacturer or Manufacturer or State or National Appurentance Installer installer Serial Providence No.

Board No.

No.

See Section 1 Paragraph 1.1 in the Attached Reoort 1

Note: Supplemental sheets in form of lists, sketches,or drawings may be used provided (1) size is 8 /2 in. x 11 in.,(2) information in items 1 through 6 on this data report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

FORM NIS-1 (back) 8.

Examinaffon Dates 03131/93 to 06/30/94

9. Inspection Interval from 08/19/86 to 08/19/%
10. Abstract of Examinations. Include a list of examinations and a statement concerning status of work required for current interval. See attached report.
11. Abstract of Conditions Noted. See attached repoIL
12. Abstract of Corrective Measures Recommended and Taken. SegI11a.rhed report.

We certify that the statements made in this report are correct and the examinations and corrective measures taken conform to the rules of the ASME Code,Section XI.

b 19M Signed Duke Power Co. By Date Owner Certificate of AuthorizationNo.(if applicable)

N/A Expiration Date N/A CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and/or the State or Province of N.C.

and employed by

'The HSBl&I Co. of have inspected the components described in this Owners Data Report during the period 03/31/93 to 06/30/94 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measu.res described in this Owners' Data Report in accordance with the requirements of the ASME code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures desc-ibed in this Owners' Data Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal liury or property damage or loss of any kind arising from or connected with this inspection.

Date 19 DM Commissions b

~

' \\ nspector's Signature I

National Board, State, Province and No.

"The Hartford Steam Boiler Inspection & Insurance Co.

200 Ashford Center North Suite 300 Atlanta Ca.,30338

.