W M

4 ll l

Duke Tour Company -

D. L REtty Catawba Nuclear Generation Department Lice President 4800ConcordRoad '

(803)831-3205 Ofluce York, SC29745 (803)S313426 Fax DUKEPOWER September 20,1994 U. S. Nuclear Regulatory Commission Attention: Document Control Desk Washington, D. C. 20555

Subject:

Catawba Nuclear Station, Unit 2 Docket No. 50-414 Special Report End ofCycle 6 Refuelir.g Outage Steam Generator Tube Inspection Report - 12 month Pursuant to Catawba Technical Specification 4.4.5.5, the following information is submitted:

1.

The following quantities of steam generator tubes were inspected from either side of the i

generator:

i Tubes Inspected Steam Generator Full Length A

4533 B

4550 C

4549 D

4545 2.

The following information is submitted regarding tube indications of imperfections.

(The attached lists identify the tubes with imperfections, their locations, and their size.)

Steam Generator Attachment A

1 B

2 C

3 D

4 270018 Dk O

9409270 m 940920 PDR 05000414

-f.

ADOCK PDR 9

I

%, tr w wwmu l

U.S. N"; lear Regulatory Commission Sept:

' er 20,1994 P-3.

The following quantities of tubes were removed from service by plugging or repaired by sleeving. (The tubes are identified in the attachments.)

Steam Generator Number ofTubes Attachment I

A 6

5 l

B 11 6

C 5

7 D

9 8

For further information, please contact Devereux Tower at (803) 831-3419.

Very truly yours, L5.

D. L. Rehn DT/

Attachments i

i i

l i

l

U.S. Nuclear Regulatory Commission September 20,1994 Page 3 xc: Mr. S. D. Ebneter Regional Administrator, Region II Mr. Roben E. Manin, Project Manager ONRR Mr. Nick Economos, Inspector Region II Mr. R. J. Freudenberger NRC Resident Inspector l

Catawba Nuclear Station i

I i

1 m

i U. S. Nuclear Regulatory Commission September 20,1994 Page 4 bxc: D. B. hiayes Z. L. Taylor J. S. Forbes G. B. Swindlehurst C. B. Cauthen NSRB Staff A. V. Carr J. E. Snyder I

J. E. Burchfield NChiPA-1 SREC PhfPA NCEMC ELL-EC050 Group File: CN-801.01 hiaster File: CN-801.01

I P

I r

s i

L ATTACilMENT 1 w

i-b i

E i

(

e i

I 1

)

BWNS TUBAN !! (Version 2.0) 06/16/1994 14:17:53 eee............

Catawba Nuclear Station - Unit Two u..u...u u...............

sfa g 05/94 RF0 Bobbin,C/L Spec'at Interest,H/L Special Interest,H/L Tubesheet,U-Bend Page 1 of 32

$/G A - ATTACHMENT #1 INDICATIONS OF IMPERFECTIONS ROW COL OUTAGE TEST TYPE IND %TW VOLTS LOCATION EXTENT 1

)

1 1 05/94 RFC Bobbin NQI 3.64 7TH TSP

+13.78 BTH TSP 05/94 RF0 H/L Special Int VOL 2.46 7TH TSP

+13.26 7TH TSP 1 3 05/94 RF0 Bobbin ODI 10 1.56 2ND TSP

+17.94 BTH TSP 05/94 RF0 M/L Special Int VOL 0.75 2ND TSP

+19.27 3RD TSP 1 6 05/94 RF0 Bobbin 001 6

2.37 4TH TSP

+0.72 BTH TSP 05/94 RF0 H/L Special Int VOL 1.37 4TH TSP

+0.76 4TH TSP 1 25 05/94 RF0 Bobbin ADI 0.50 18TH TSP

+13.18 8TH TSP 05/94 RF0 Bobbin ADI 2.41 19TH TSP

+1.72 8TH TSP 05/94 RF0 C/L Special Int VOL 0.35 197H TSP

+1.52 19TH TSP 05/94 RF0 C/L Special Int VOL 0.54 18TH TSP

+12.98 18TH TSP 05/94 RF0 C/L Special Int VOL 0.62 18TH TSP

+20.98 18TH TSP 1 49 05/94 RF0 Bobbin ODI 7

1.03 6TH TSP

+32.49 BTH TSP l

1 58 05/94 RFO Bobbin ADI 1.59 7TH TSP

+2.60 BTH TSP 05/94 RF0 H/L Special Int VOL 1.79 7TH TSP

+2.22 TTH TSP 1 63 05/94 RF0 Bobbin NQI 0.68 STH TSP

+13.15 BTH TSP 05/94 RF0 H/L Special Int VOL 0.50 STH TSP

+13.06 STH TSP 1 64 05/94 RF0 Bobbin NQI 0.80 2ND TSP

+11.18 BTH TSP l

05/94 RF0 H/L Special Int VOL 0.41 2ND TSP

+10.80 2ND TSP 1 84 05/94 RF0 Bobbin 001 11 1.74 4TH TSP

+40.70 STH TSP 1 93 05/94 RF0 Bobbin NQI 1.32 4TH TSP

+9.67 BTH TSP 05/94 RF0 Bobbin NQ1 2.03 4TH TSP

+4.89 STH TSP 05/94 RF0 Bobbin 001 1

1.04 10TH TSP

+12.09 8TH TSP 05/94 RF0 H/L Special Int VOL 0.86 4TH TSP

+7.50 4TH TSP i

05/94 RF0 H/L Special Int VOL 0.94 4TH TSP

+9.47 4TH TSP

)

05/94 RF0 H/L Special Int VOL 1.14 4TH TSP

+4.78 4TH TSP j

05/94 RF0 H/L Special Int VOL 1.33 4TH TSP

+6.16 4TH TSP 1 104 05/94 RF0 Bobbin 001 23 0.38 12TH TSP

+32.46 BTH TSP 1 109 05/94 RF0 Bobbin NQI 0.84 6TH TSP

+36.40 BTH tsp 05/94 RF0 H/L Special Int VOL 0.33 7TH TSP

-16.76 7TH TSP 05/94 RF0 H/L Special Int VOL 0.39 7TH TSP

-6.15 7TH TSP 05/94 RF0 H/L Special Int VOL 0.50 7TH TSP

-12.23 7TH TSP 05/94 RF0 H/L Special Int VOL 0.61 7TH TSP

-1.95 77H TSP 2 2 05/94 RF0 Bobbin ADI 1.22 12TH TSP

+2.96 to

+9.24 8TH TSP 05/94 RF0 C/L Special Int VOL 0.55 12TH TSP

+2.96 to

+9.24 12TH TSP 2 16 05/94 RF0 Bobbin NQI 0.32 18TH TSP

+22.16 BTH TSP i

2 25 05/94 RF0 Bobbin ADI 7.26 TTS CL

+4.12 BTH TSP l

05/94 RF0 C/L Special Int VOL 1.01 TTS-CL

+3.45 191H TSP 2 36 05/94 RF0 Bobbin NQI 0.79 4TH TSP

+6.52 BTH TSP 2 37 05/94 RF0 Bobbin 001 3

0.70 STH TSo

+1.66 BTH TSP 2 42 05/94 RF0 Bobbin ADI 2.88 3RD TSP

+31.27 8TH TSP 05/94 RF0 Bobbin ADI 7.09 4TH TSP

+14.78 BTH TSP 05/94 RF0 H/L Special Int VOL 0.93 4TH TSP

-5.57 4TH TSP 05/94 RF0 H/L Special Int VOL 1.10 4TH TSP

+15.36 STH TSP 2 43 05/94 RF0 Bobbin ADI 5.31 3RD TSP

+19.f' 8TH TSP 05/94 RF0 H/L Special Int VOL 0.90 3RD TSP

+20..

4TH TSP 2 52 05/94 RF0 Bobbin ODI 7

0.86 9TH TSP

-0.91 8TH TSP 2 66 05/94 RFC Bobbin NQI 1.68 1BTH TSP

+27.41 87H TSP 05/94 RF0 C/L Special Int VOL 0.92 18TH TSP

+27.41 187H TSP 2 73 05/94 RF0 Bobbin NQI 2.01 iST TSP

+14.59 BTH TSP 05/94 RF0 H/L Special ht VOL D.78 1ST TSP

+14.42 1ST TSP 2 74 05/94 RF0 Bobbin NQ1 0.42 3RD TSP

+18.36 BTH TSP 05/94 RF0 Bobbin NQI 0.61 3RD TSP

+17.01 BTH TSP 05/94 RF0 Bobb

  • NQI 0.78 2ND TSP

+19.38 STH TSP 05/94 RF0 Bobt.)

NQI 0.79 3RD TSP

+8.25 BTH TSP 05/94 RF0 Bobidi NCI 1.14 2ND TSP

+15.71 BTH TSP 05/94 RF0 BoWn i NQI 1.15 3RD TSP

+9.54 8TH TSP 05/94 RF0 Bobrin ODI 29 1.04 2ND TSP

+18.18 BTH TSP 2 75 05/94 RF0 BobLir 001 12 0.73 3RD TSP

+12.83 8TH TSP 2 84 05/94 RF0 Bobbin NOI 0.53 2ND TSP

+14.82 BTH TSP 05/94 RF0 Bobbin NQI 0.71 2ND TSP

+16.21 BTH TSP 05/94 RF0 Bobbin NQI 0.83 2ND TSP

+17.52 BTH TSP 05/94 RF0 H/L Special Int VOL 0.95 2ND TSP

+16.07 to +21.08 2ND TSP 2 99 05/94 RF0 Bobbin NO!

0.53 4TH TSP

+5.44 11TH TSP 05/94 RF0 H/L Special Int VOL 0.59 4TH TSP

+6.20 4TH TSP 2 101 05/94 RF0 Bobbin NQI 0.72 71H TSP

+9.67 8TH TSP 05/94 RF0 Bobbin NQ1 0.90 5TH TSP

+2.34 STH TSP

ee**************************

BWNS TUBAN !! (Version 2.0) 06/16/1994 14:17:53

      • eeeeeeee****eeeeeeeee***e Catawba Nuclear Station - Unit Two S/G A eeeeeeeeeeeeeeee************

05/94 RF0 Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U-Bend Page 2 of 32

$/G A - ATTACHMENT #1 INDICATIONS OF IMPERFECTIONS RDW COL OUTAGE TEST TYPE IND %TW VOLTS LOCATION EXTENT 1 05/94 RF0 Bobbin NQ1 0.96 STH TSP

+1.66 8TH TSP 05/94 RF0 Bobbin NQI 1.08 77H TSP

+11.06 BTH TSP 05/94 RF0 Bobbin NQI 1.17 STH TSP

+6.20 BTH TSP 05/94 RF0 Bobbin NQI 1.42 STH TSP

+3.66 8TH TSP 05/94 RF0 H/L Special Int VOL 0.69 71H TSP

+9.07 7TH TSP 05/94 RF0 H/L Special Int VOL 1.58 7TH TSP

+7.97 7TH TSP 05/94 RF0 H/L Special Int VOL 0.74 STH TSP

+1.50 to

+7.00 STH TSP 2 109 05/94 RF0 Bobbin ADI 2.34 2ND TSP

+20.05 8TH TSP 05/94 RF0 H/L Special Int VOL 0.40 2ND TSP

+16.16 2ND TSP 05/94 RF0 H/L Special Int VOL 0.63 2ND TSP

+21.18 2ND TSP 2 114 05/94 RFO Bobbin No!

0.96 7TH TSP

+12.44 BTH TSP 05/94 RF0 H/L Special Int VOL 0.72 7TH TSP

+9.26 7TH TSP 05/94 RF0 H/L Special Int VOL 1.07 7TH TSP

+10.41 7TH TSP 05/94 RF0 H/L Special Int VOL 1.41 77H TSP

+13. 75 7TH TSP 3 6 O!!94 RF0 Bobbin NQI a.51 11TH TSP

+28.77 BTH TSP 05/94 RF0 C/L Special Int VOL 0.42 10TH TSP

-13.38 10TH TSP 3 9 05/94 RF0 Bobbin NQ1 0.2613TH TSP

+37.43 BTH TSP 05/94 RF0 Bobbin NQ1 0.43 13TH TSP

+31.63 BTH TSP 05/94 RF0 Bobbin NQI 0.43 15TH TSP

+4.28 81H TSP 05/94 RF0 Bobbin NQI 0.49 16TH TSP

+15.54 BTH TSP 05/94 RFO Bobbin WQt 0.52 12TH TSP

+8.39 BTH TSP 05/94 RF0 Bobbin NQ1 0.55 13fH TSP

+18.78 BTH TSP 05/94 RF0 Bobbin NQI 0.62 1STH TSP

+9.86 BTH TSP 05/94 RF0 Bobbin NQI 0.84 16TH TSP

+11.45 8TH TSP 05/94 RF0 Bobbin NQI 0.89 15TH TSP

+4.83 BTH TSP 05/94 RF0 Bobbin 001 21 0.34 16TH TSP

+9.52 BTH TSP 05/94 RF0 Robbin ADI 1.99 TTS CL

+0.00 to

+3.88 BTH TSP 05/94 RF0 Bobbin ADI 3.76 19TH TSP

+0.64 to

+3.04 8TH TSP 05/94 RF0 C/L Special Int VOL 0.3715f H TSP

+4.12 15TH TSP 05/94 RF0 C/L Special Int VOL 0.39 13TH TSP

+37.25 12TH TSP 05/94 RF0 C/L special Int VOL 0.56 16TH TSP

+11.80 16TH TSP 05/94 RF0 C/L Specist Int VOL 0.59 1STH TSP

+4.78 15TH TSP 05/94 RF0 C/L Special Int VOL 0.62 13TH TSP

+18.75 12TH TSP 05/94 RF0 C/L Special Int VOL 0.63 16TH TSP

+15.61 16TH TSP 05/94 RF0 C/L Special Int VOL 0.69 13TH TSP

+31.64 12TH TSP 05/94 RF0 C/L Special Int VOL 0.79 12TH TSP

+B.42 12TH TSP 05/94 RF0 C/L Special Int VOL 0.86 15TH TSP

+9.26 15TH TSP 05/94 RF0 C/L Special Int VOL 0.83 TTS CL

+0.26 to

+3.67 18TH TSP 05/94 RF0 C/L Special Int VOL 0.87 19TH TSP

+1.36 to

+3.05 18TH TSP 3 10 05/94 RF0 Bobbin NQI 0.33 4TH TSP

+20.25 BTH TSP 05/94 RF0 Bobbin NQI 0.60 4TH TSP

+21.56 BTH TSP 05/94 RF0 Bobbin NQI 0.69 4TH TSP

+29.48 BTH TSP 05/94 RF0 Bobbin NQ1 0.78 4TH TSP

+22.86 BTH TSP 05/94 RF0 Bobbin NQ1 1.10 4TH TSP

+24.24 BTH TSP 05/94 RF0 Bobbin NQ1 1.10 4TH TSP

+28.15 BTH TSP 05/94 RF0 Bobbin NQI 1.19 4TH TSP

+26.82 BTH TSP 05/94 RF0 Bobbin No!

1.25 4TH TSP

+25.52 BTH TSP 05/94 RF0 Bobbin ODI 7

0.72 10TH TSP

+8.08 STH TSP 05/94 RF0 N/L Special Int VOL 0.34 STH TSP

-12.70 STH TSP 05/94 RF0 H/L Special Int VOL 0.38 STH TSP

-13.26 STH TSP 05/94 RF0 H/L Special Int VOL 0.38 STH TSP

-16.91 STH TSP 05/94 RF0 H/L Special Int VOL 0.46 STH TSP

-15.65 STH TSP 05/94 RF0 H/L Special Int VOL 0.48 STH TSP

-18.11 STH TSP 05/94 RFO H/L Special Int VOL 0.49 STH TSP 18.71 STH TSP 05/94 RF0 H/L Special Int VOL 0.52 STH TSP 16.24 STH TSP 05/94 RF0 H/L Special Int VOL 0.54 STH TSP

-14.49 STH TSP 05/94 RF0 H/L Special Int VOL 0.55 STH TSP

-15.18 STH TSP 05/94 RF0 H/L Special Int VOL 0.68 STH TSP

-17.48 STH TSP 05/94 RF0 H/L Special Int VOL 0.73 STH TSP

-13.83 STH TSP 05/94 RF0 C/L Special Int VOL 0.55 10TH TSP

+ 7. 22 10TH TSP 05/94 RF0 C/L Special Int VOL 0.57 10TH TSP

+6.39 10Th TSP 3 12 05/94 RF0 Bobbin NQI 1.28 7TH TSP

+0.16 BTH TSP 05/94 RF0 Bobbin NQI 1.31 77H TSP

-1.21 8TH TSP 05/94 RF0 H/L Special Int VOL 0.36 7TH TSP

-1.71 7TH TSP 05/94 RF0 M/L Special Int VOL 0.76 7TH TSP

+1.44 8TH TSP 05/94 RF0 H/L Special Int VOL 1.48 TTH TSP

j

......................e*****

BWNS TUBAN 11 (Version 2.0) 06/16/1994 14:17:53

.......e**e...**************

Catawba Nuclear Station - Unit Two Sfg g 05/94 RF0 Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U-Bend l

Page 3 of 32 S/G A - ATTACHMENT #1 INDICATIONS OF IMPERFECTIONS ROW COL OUTAGE TEST TYPE IND %TW VOLTS LOCATION EXTENT 1 3 14 05/94 RF0 Bobbin ADI 7.50 4TH TSP

+3.52 BTH TSP 05/94 RF0 Bobbin ADI 1.20 17TH TSP

+14.53 BTH TSP 05/95 RFO Bobbin ADI 1.86 17TH TSP

+15.83 BTH TSP 05/9. RF0 Bobbin

%c!

1.17 16TH TSP

-1.01 BTH TSP 05/04 RF0 Bobbin 001 30 1.19 16TH TSP

+1.38 8TH TSP 05/?4 RF0 H/L Special Int VOL 0.43 4TH TSP

+3.50 4TH TSP 05j94 RF0 H/L Special Int VOL 0.89 4TH TSP

+8.77 4TH TSP 05/v4 RF0 C/L Special Int VOL 0.63 17TH TSP

+14.35 16TH TSP 05/94 RF0 C/L Special Int VOL 0.68 16TH TSP

+1.56 16TH TSP 05/94 RF0 C/L Special Int VOL 0.79 17TH TSP

+15.74 16TH TSP 05/94 kFO C/L Special Int VOL 0.83 177H TSP

+16.96 16TH TSP 05/94 RF0 C/L Special Int VOL 1.01 16TH TSP

+0.79 16TH TSP 3 22 05/94 RF0 Bobbin ADI 5.09 6TH TSP

+4.60 81H TSP 05/94 RFC H/L Special Int VOL 0.83 6TH TSP

+4.70 7TH TSP 3 31 05/94 RFC Bobbin NQ1 0.38 4TH TSP

+16.21 8TH TSP 05/94 RF0 Bobbin NQI 0.65 4TH TSP

+15.59 8TH TSP 05/94 RF0 H/L Special Int VOL 0.80 4TH TSP

+14.68 STH TSP 3 63 05/94 RF0 Bobbin NQI 1.36 1ST TSP

+17.01 8TH TSP 05/94 RF0 H/L Special Int VOL 1.42 1ST TSP

+ 16. 75 iST TSP 3 67 05/94 RF0 Bobbin NQI 0.41 13TH TSP

+31.34 BTH TSP 3 83 05/94 RF0 Bobbin 001 13 2.55 10TH TSP

+38.48 BlH TSP 4 12 05/94 RF0 Bobbin NQ1 0.61 STH TSP

+4.57 8TH TSP 05/94 RF0 H/L Special Int VOL 0 ?4 5fH TSP

+3.44 6TH TSP 05/94 RF0 H/L Special Int VOL 3i STH TSP

+5.78 6TH TSP 05/94 RFO H/L Special Int VOL u.34 STH TSP

+4.63 6TH TSP 4 41 05/94 RF0 Bobbin NQI 0.35 14TH TSP

+11.84 8TH TSP 05/94 RF0 C/L Special Int VOL 0.41 14TH TSP

+11.81 14TH TSP 4 51 05/94 RF0 Sobbin ODI 17 0.31 11TH TSP

+12.31 BTH TSP 4 53 05/94 RF0 Bobbin 001 16 0.65 1ST TSP

+14.92 8TH TSP 4 55 05/94 RF0 Bobbin 001 2

1.23 2ND TSP

+26.14 8TH TSP 4 74 05/94 RF0 H/L Tubesheet VOL 0.19 TTS-HL

-0.11 TTS ML 4 78 05/94 RF0 Bobbin 001 10 1.27 2ND TSP

+10.95 BTH TSP 4 85 05/94 RF0 Bobbin 001 8

2.39 7TH TSP

+15.76 8TH TSP 4 111 05/94 RF0 Bobbin 001 2

1.26 IST TSP

+23.22 BTH TSP 5 29 05/94 RF0 Bobbin ADI 5.90 11TH TSP

+16.49 F/L 05/94 RF0 C/L Special Int VOL 0.76 11TH TSP

+16.22 11TH TSP 5 34 05/94 RF0 Bobbin 001 21 1.59 TTS-CL

+4.29 F/L 05/94 RF0 Bobbin 001 27 1.78 13TH TSP

+ 7. 72 F/L 5 37 05/94 RF0 Bobbin ADI 11.89 12TH TSP

+12.92 F/L 05/94 RF0 Bobbin 001 25 0.81 15TH TSP

+8.50 F/L 05/94 RF0 C/L Special Int VOL 1.76 12TH TSP

+12.24 12TH TSP 5 58 05/94 RF0 Bobbin No!

0.36 IST TSP

+8.27 F/L 05/94 RF0 Bobbin 001 3

8.76 12TH TSP

+1.51 F/L 05/94 RF0 Bobbin 001 9

5.46 13TH TSP

+16.B4 F/L 05/94 RF0 Bobbin DDI 11 5.01 14TH TSP

+16.07 F/L 05/94 RF0 H/L Special Int VOL 0.34 1ST TSP

+8.01 1ST TSP 05/94 RF0 C/L Special Int VOL 0.55 13TH TSP

-1.95 137H TSP 05/94 RF0 C/L Special Int VOL 0.81 13TH TSP

+16.81 13TH TSP 05/94 RF0 C/L Special Int VOL 0.94 12TH TSP

+1.42 12TH TSP 5 60 05/94 RF0 Bobbin ADI 1.18 3RD TSP

+1.71 to

+6.82 F/L 05/94 RF0 H/L Special Int VOL 0.41 3RD TSP

+1.83 3RD TSP 05/94 RF0 H/L Special Int VOL 0.58 3RD TSP

+3.24 3RD TSP 05/94 RF0 H/L Special Int VOL 0.68 3RD TSP

+4.40 3RD TSP 5 62 05/94 RF0 Bobbin ADI 6.96 13TH TSP

+35.45 F/L 05/94 RF0 t/L Special Int VOL 0.40 12TH TSP

-2.53 12TH TSP 05/94 RF0 C/L Special Int VOL 1.10 12TH TSP

-7.57 12TH TSP 5 64 05/94 RF0 Bobbin ADI 2.14 1ST TSP

+12.70 to +21.96 F/L 05/94 RF0 H/L Special Int VOL 0.25 1ST TSP

+11.81 to +20.07 1ST TSP 5 74 05/94 RF0 Bobbin DDI 14 1.39 2ND TSP

+4.26 F/L 5 84 05/94 RTO Bobbin 001 14 1.16 4TH TSP

+4.76 F/L 5 88 05/94 RTO Bobbin ADI 1.771ST TSP

+22.76 F/L 05/94 RF0 H/L Special int VOL 0.49 1ST TSP

+21.66 1ST TSP 5 99 05/94 RF0 Bobbin 001 11 2.70 10TH TSP

+27.74 F/L 5 108 05/94 RF0 Bobbin 001 18 0.86 TTH TSP

+32.51 F/L 6 2 05/94 RF0 Bobbin 001 12 0.90 13TH TSP

+11. 75 F/L 05/94 RTO Bobbin 001 23 5.15 16TH TSP

+9.12 F/L

BWNS TUBAN II (Version 2.0) 06/16/1994 14:17:53 eeeeee**********************

Catawba Nuclear Station - Unit Two eeeeee......................

gfg g eeeeee............**********

05/94 RF0 e.......................****

Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U-Bend Page 4 of 32 S/G A - ATTACHMENT #1 INDICATIONS OF IMPERFECTIONS ROW COL DUTAGE TEST TYPE IND %TW VOLTS LOCATION EXTENT 1 6 3 05/94 RF0 Bobbin 001 29 3.79 1ST TSP

+24.81 F/L 05/94 RF0 Bobbin 001 4

1.72 10TH TSP

+15.38 F/L 05/94 RF0 Bobbin DDI 18 3.27 18TH TSP

+2.64 F/L 05/94 RF0 H/L Special Int VOL 0.97 2ND TSP

-3.86 2ND TSP 05/94 RF0 C/L Special Int VOL 0.31 10TH TSP

+14.46 10TH TSP 05/94 RF0 C/L Special ITt VOL 0.89 18TH TSP

+2.27 18TH TSP 6 4 05/94 RF0 Bobbin 001 9

0.67 14TH TSP

+7.42 F/L 05/94 RF0 C/L Special Int VOL 0.46 14TH TSP

+8.46 14TH TSP 05/94 RF0 C/L Special' Int VOL 0.52 14TH TSP

+7.51 14TH TSP 6 5 05/94 RF0 Bobbin ODI 10 2.71 15TH TSP

+4.33 F/L 6 19 05/94 RF0 Bobbin ADI 2.23 12TH TSP

+21.24 F/L 6 21 05/94 RF0 Bobbin ODI 28 1.19 7TH TSP

+32.62 F/L 6 24 05/94 RFO Bobbin ADI 0.85 2ND TSP

+31.50 F/L 05/94 RF0 H/L Special Int VOL 0.70 3RD TSP

-6.21 3RD TSP 6 31 05/94 RF0 Bobbin ADI 6.98 12TH TSP

+34.00 F/L 6 35 05/94 RF0 Bobbin ADI 6.13 6TH TSP

+9.76 F/L 05/94 RF0 Bobbin ADI 6.24 6TH TSP

+28.58 F/L 05/94 RTO Bobbin ADI 6.97 6TH TSP

+7.42 F/L 05/94 RF0 N/L Specia:

1"*

VOL 1.27 6TH TSP

+10.82 TTH TSP 05/94 RF0 H/L Special int VOL 1.52 6TH TSP

+17.76 7TH TSP 05/94 RF0 H/L Special Int VOL 1.69 6TH TSP

+8.71 7TH TSP 05/94 RF0 H/L Special Int VOL 2.11 6TH TSP

+31.04 TTH TSP 6 36 05/94 RFC Bobbin ADI 3.13 15TH TSP

+12.86 F/L 05/94 RF0 Bobbin ADI 3.7511TH TSP

+17.19 F/L 05/94 RF0 C/L Special Int VOL 0.26 11TH TSP

+14.78 11TH TSP 05/94 RF0 C/L Special Int VOL 0.34 15TH TSP

+13.06 14TH TSP 05/94 RF0 C/L Special Int VOL 0.40 11TH TSP

+16.92 11TH TSP 6 37 05/94 RF0 Bobbin ADI 4.27 iST TSP

+4.17 F/L 6 40 05/94 RF0 Bobbin 001 20 1.97 10TH TSP

+39.62 F/L 6 53 05/94 RF0 Bobbin ADI 6.65 2ND TSP

+33. 75 F/L 05/94 RFC Bobbin ADI 7.05 191H TSP

+1.49 F/L 05/94 RF0 H/L Special int VOL 0.28 3RD TSP 2.52 3RD TSP 05/94 RF0 C/L Special Int VOL 0.91 19TH TSP

+1.51 197H TSP 6 54 05/94 RF0 Bobbin ADI 7.60 STH TSP

+ 3. 73 F/L 05/94 RF0 Bobbin ADI 3.7512TH TSP

+13.64 F/L 05/94 RF0 H/L Special Int VOL 1.12 STH TSP

+4.25 6TH TSP 05/94 RF0 C/L Special Int VOL 0.36 12TH TSP

+12.94 12TH TSP 6 62 05/94 RF0 Bobbin DDI 3

1.00 4TH TSP

+21.42 F/L 6 75 05/94 RF0 Bobbin 001 23 2.17 197H TSP

+6.97 F/L 05/94 RF0 Bobbin 001 27 1.79 11TH TSP

+10.20 F/L 6 77 05/94 RF0 Bobbin ADI 4.65 11TH TSP

+32.94 F/L 05/94 RF0 C/L Special Int VOL 1.53 10TH TSP 9.66 10TH TSP 6 81 05/94 RF0 Bobbin 001 12 1.87 11TH TSP

+4.25 F/L 05/94 RF0 Bobbin ODI 30 2.81 11TH TSP

+19.35 F/L 6 84 05/94 RF0 Bobbin DDI 22 1.74 STH TSP

+6.94 F/L 6 91 05/94 RF0 Bobbin DDI 10 3.49 4TH TSP

+13.97 F/L 05/94 RF0 Bobbin DDI 6

0.65 10TH TSP

+19.59 F/L 05/94 RF0 H/L Special Int VOL 0.85 4TH TSP

+13.86 4TH TSP 05/94 RF0 C/L Special Int VOL 0.43 10TH TSP

+19.59 10TH TSP 6 99 05/94 RF0 Bobbin NQI 0.82 16TH TSP

-1.36 F/L 05/94 RF0 Bobbin DDI 21 1.89 10TH TSP

+11.97 F/L 05/94 RF0 C/L Special Int VOL 0.43 16TH TSP

+3.06 16TH TSP 05/94 RF0 C/L Special Int Vm 0.51 16TH TSP

-1.36 16TH TSP 6 114 05/94 RF0 Bobbin ADI 2.80 10TH TSP

+36.83 F/L 05/94 RF0 C/L Special Int VOL 1.52 97H TSP

-9.36 9TH TSP 05/94 RF0 C/L Special Int VOL 0.3510TH TSP

+31. 72 10TH TSP 7 3 05/94 RF0 Bobbin NQI 0.38 7TH TSP

+28.71 F/L 7 14 05/94 RF0 Bobbin DDI 27 1.63 TTS-CL

+6.32 F/L 7 15 05/94 RF0 Bobbin 001 6

1.18 TTS-CL

+4.67 F/L 7 26 05/94 RF0 Bobbin 001 22 5.13 3RD TSP

+9.16 F/L 7 31 05/94 RF0 Bobbin 001 10 2.43 4TH TSP

+ 9. 32 F/L 7 40 05/94 RF0 Bobbin NQI 0.35 191H TSP

+4.09 F/L 05/94 RF0 Bobbin NQ1 0.7917TH TSP

+13.23 F/L 05/94 RF0 Bobbin DDI 37 0.69 181H TSP

+12.98 F/L I

05/94 RF0 C/L Special Int VOL 0.40 197H TSP

+4.21 19TH TSP 05/94 RF0 C/L Special Int VOL 0.66 1dTH TSP

+12.74 18TH TSP

BWNS TUBAN ll (Version 2.0) 06/16/1994 14:17:53 Catawba Nuclear Station - Unit 1wo

...................+*.......

Sfg g 05/94 RF0 Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U Bend Page 5 of 32 S/G A ATTACHMENT #1 INDICATIONS OF IMPERFECTIONS ROW COL OUTAGE TEST TYPE IND %TW VOLTS LOCATION EXTENT 1 05/94 RF0 0/L Special int VOL 1.38 17TH TSP

+13.27 17TH TSP 7 56 05/94 RF0 Bobbin ADI 7.70 STM TSP

+5.02 F/L 05/94 RF0 H/L Special Int VOL 0.70 STH TSP

+6.01 6TH TSP 7 61 05/94 RF0 Bobbin DDI 15 2.10 6TH TSP

+19.68 F/L 05/94 RF0 Bobbin DDI 24 2.25 6TH TSP

+15.41 F/L 7 62 05/94 RF0 Bobbin NQI 0.48 10TH TSP

+33.41 F/L 05/94 RF0 C/L Special Int VOL 0.28 9TH TSP

-12.56 9TH TSP 05/94 RF0 C/L Special Int VOL 0.36 97H TSP

-11.67 9TH TSP i

05/94 RF0 C/L Special Int VOL 0.37 9TH TSP

-9.19 9TH TSP 7 65 05/94 RF0 Bobbin 001 4

0.98 197H TSP

+1.87 F/L 05/94 RF0 C/L Special Int VOL 1.62 197H TSP

+2.03 19TH TSP 7 67 05/94 RF0 Bobbin 001 20 0.58 187H TSP

+10.23 F/L 05/94 RF0 C/L Special Int VOL 1.07 18TH TSP

+10.23 181H TSP 7 69 05/94 RF0 Bobbin ADI 5.37 BTH TSP

-1.53 F/L 05/94 RF0 Bobbin 001 28 0.67 TTS HL

+6.02 F/L 05/94 RF0 Bobbin 001 30 2.09 TTS-HL

+4. 73 F/L 05/94 RF0 Bobbin 001 10 0.58 7TH TSP

+31.07 F/L 05/94 RF0 Bobbin 001 21 1.44 3RD TSP

+4.43 F/L 05/94 RF0 H/L Special Int VOL 0.63 3RD TSP

+4.13 3RD TSP 05/94 RF0 H/L Special Int VOL 0.63 BTH TSP

-11.47 BTH TSP 05/94 RF0 H/L Special Int VOL 0.68 BTH TSP

-1.61 BTH TSP 05/94 RF0 H/L Special Int VOL 0.76 BTH TSP

-12.28 BTH TSP 7 70 05/94 RF0 Bobbin 001 11 2.7717TH TSP

+7.23 F/L 05/94 RF0 Bobbin 001 20 2.02 16TH TSP

+12.50 F/L 05/94 RF0 C/L Special Int VOL 0.52 16TH TSP

+12.27 16TH TSP 05/94 RF0 C/L Special Int VOL 0.82 17TH TSP

+6.84 16TH TSP 7 90 05/94 RF0 Bobbin ODI 39 0.72 7TH TSP

+30.91 F/L 05/94 RF0 Bobbin 001 24 0.73 10TH TSP

+31.94 F/L 7 93 05/94 RF0 Bobbin 001 3

1.171ST TSP

+6.91 F/L 05/94 RF0 H/L Special Int VOL 0.23 1ST TSP

+0.68 1ST TSP 05/94 RF0 H/L Special Int VOL 0.98 1ST TSP

+6.44 1ST TSP 7 94 05/94 RF0 Bobbin 001 22 1.25 1ST TSP

+20.03 F/L 7 97 05/94 RF0 Bobbin NQI 0.62 11TH TSP

+9.41 F/L 7 102 05/94 RF0 Bobbin 001 18 3.30 6TH TSP

+30.17 F/L 7 104 05/94 RF0 Bobbin 001 24 1.171ST TSP

+10.09 F/L

[

7 106 05/94 RF0 Bobbin ADI 3.82 6TH TSP

+7.40 F/L 7 113 05/94 RF0 Bobbin DDI 24 1.41 TTS-CL

+ 3. 73 F/L 8 5 05/94 RF0 Bobbin DDI 27 1.11 12TH TSP

+4.32 F/L 8 15 05/94 RF0 Bobbin ADI 3.21 197H TSP

+3.83 F/L 8 16 05/94 RF0 Bobbin 001 23 3.86 1ST TSP

+19.89 F/L 05/94 RTO Bobbin 001 11 0.26 10TH TSP

+29.06 F/L 8 19 05/94 RF0 Bobbin ADI 13.67 4TH TSP

+30.79 F/L 05/94 RF0 H/L Special Int VOL 1.12 STH TSP

-12.76 STH TSP 8 24 05/94 RF0 Bobbin DDI 30 2.75 77H TSP

+33.28 F/L 05/94 RF0 H/L Special Int VOL 1.02 8TH TSP

-10.53 BTH TSP 8 30 05/94 RF0 Bobbin ODI 23 0.52 13TH TSP

+9.37 F/L 8 34 05/94 RF0 Bobbin ODI 21 0.73 11TH TSP

+30.73 F/L 8 35 05/94 RF0 Bobbin NQI 0.34 19TH TSP

+ 7. 28 F/L 05/94 RF0 Bobbin 001 17 0.59 19TH TSP

+8.33 F/L 8 38 05/94 RF0 Bobbin 001 28 0.53 2ND TSP

+14.62 F/L 8 39 05/94 RF0 Bobbin 001 29 1.62 13TH TSP

+ 1. 64 F/L 05/94 RF0 C/L Special int VOL 0.88 13TH TSP

+1.33 13TH TSP 8 42 05/94 RF0 Bobbin DDI 13 1.52 10TH TSP

+36.92 F/L 8 44 05/94 RF0 Sobbin DDI 18 2.28 2ND TSP

+25.77 F/L 05/94 RF0 Bobbin 001 14 0.60 15TH TSP

+8.77 F/L 05/94 RF0 Bobbin 001 18 0.67 14TH TSP

+4.34 F/L 8 45 05/94 RF0 Bobbin 001 24 2.40 STH TSP

+35.38 F/L 05/94 RF0 Bobbin 001 11 3.14 15TH TSP

+14.99 F/L 05/94 RF0 Bobbin 001 16 0.71 15TH TSP

+2.07 F/L 05/94 RF0 Bobbin DDI 19 1.33 16TH TSP

+11.15 F/L 05/94 RF0 C/L Special int VOL 0.22 15TH TSP

+2.05 15TH TSP 8 46 05/94 RF0 Bobbin ODI 11 4.55 STH TSP

+36.20 F/L 05/94 RF0 Bobbin DDI 21 4.08 18TH 1SP

+4. 73 F/L 8 47 05/94 RF0 Bobbin DDI 24 5.14 6TH TSP

+2.32 F/L 05/94 RF0 H/L Spectat Int VOL 1.31 6TH TSP

+3.16 7TH TSP 8 52 05/94 RF0 Bobbin DDI 5

0.68 3RD TSP

+3.92 F/L

'l 1

1 B,$ 1u m,, tv,,,,on,.0, 06,16,1,,4 14,,7,53 Catawba Nuclear Station

  • Unit Two S/G A 05/94 RF0 Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U-Bend Page 6 of 32

$/G A - ATTACHMENT #1 INDICATIONS OF IMPERFECTIONS ROW COL OUTAGE TEST TYPE IND %TW VOLTS LOCATION EXTENT 1 u5/94 RF0 H/L Special Int VOL 1.31 3RD TSP

+4.47 4TH TSP 8 58 05/v4 'O Bobbin 001 29 1.54 17TH TSP

+14.60 F/L l

8 63 05/94 Rtc Robbin 001 10 3.66 11TH TSP

+33.53 F/L 8 74 05/94 RFP ocobin ODI 6

2.53 4TH TSP

+28.65 F/L 8 87 05/94 RFO Bobbin 001 34 2.61 12TH TSP

+27.19 F/L 8 91 05/94 RF0 Bobbin ADI 3.70 16TH TSP

+11.16 F/L 05/94 RF0 C/L Special Int VOL 0.34 16TH TSP

+11.16 16TH TSP 8 96 05/94 RF0 Bobbin 001 31 0.32 1STH TSP

+10.59 F/L 8 107 05/94 RF0 Bobbin NQI 0.42 10TH TSP

+36.65 F/L 05/94 RF0 Bobbin No!

0.95 10TH TSP

+18.93 F/L 05/94 RF0 Bobbin 001 4

2.24 7TH TSP

+10.48 F/L 05/94 RF0 Bobbin 001 41 1.11 7TH TSP

+18.60 F/L 05/94 RF0 C/L Special Int VOL 0.63 9TH TSP

-4.17 9TH TSP 05/94 RF0 H/L Special Int VOL 0.40 7TH TSP

+18.35 TTH TSP 8 108 05/94 RF0 Bobbin 001 3

2.81 11TH TSP

+14.34 F/L 05/04 RF0 Bobbin 001 15 2.79 11TH TSP

+9.33 F/L 05/94 RF0 Bobbin 001 23 1.75 11TH TSP

+17.13 F/L 8 109 05/94 RF0 Bobbin No!

6.31 STH TSP

+28,10 F/L 05/94 RF0 U-Bend VOL 0.94 BTH TSP

+ 27.56 9TH TSP 8 113 05/94 RF0 Bobbin 001 8

0.70 7TH TSP

+22.36 F/L 05/94 RF0 Bobbin 001 33 0.67 71H TSP

+18.80 F/L 9 6 05/94 RF0 Bobbin 001 27 2.43 1ST TSP

+20.31 F/L 9 8 05/94 RFO Bobbin ADI 10.26 BTH TSP

+17.80 F/L 9 10 05/94 RF0 Bobbin 001 3

0.44 10TH TSP

+30.60 F/L 9 11 05/94 RF0 Dobbin NOI 0.84 13TH TSP

+4.82 F/L 05/94 RF0 C/L Special Int VOL 0.43 13TH TSP

+4.90 13fH TSP 9 15 05/94 RF0 Bobbin NQI 1.88 171H TSP

+11.64 F/L 05/94 RF0 C/L Special Int VOL 0.48 171H TSP

+7.04 171H TSP 05/94 RF0 C/L Special Int VOL 1.20 17TH TSP

+11.36 17TH TSP 9 20 05/94 RF0 Bobbin ADI 3.65 14TH TSP

+11.09 F/L 05/94 RF0 Bobbin ADI 4.64 11TH TSP

+29.06 F/L 05/94 RF0 C/L Special Int VOL 0.31 14TH TSP

+10.38 14TH TSP 05/94 RF0 C/L Special Int VOL 1.08 10TH TSP

-14.15 10TH TSP 9 21 05/94 RF0 Bobbin NQ1 0.86 13TH TSP

+23.15 F/L 05/94 RF0 C/L Special Int VOL 0.39 13fH TSP + 17.54 13fH TSP 05/94 RTO C/L Special Int VOL 0.44 13fH TSP

+21.05 13TH TSP 05/94 RF0 C/L Special Int VOL 0.6713TH TSP

+19.02 131H TSP 05/94 RF0 C/L Special Int VOL 0.80 13TH TSP

+22.68 131H TSP 9 41 05/94 RF0 Bobbin ADI 1.91 13fH TSP

+5.68 F/L 05/94 RF0 C/L Special Int VOL u.37 13fH TSP

+5.52 13TH TSP 9 46 05/94 RF0 Bobbin ADI 1.94 16TH TSP

+3.99 F/L 05/94 RF0 C/L Special Int VOL 0.37 16TH TSP

+3.58 16TH TSP 9 59 05/94 RF0 Bobbin ADI 6.31 2ND TSP

+30.36 F/L 05/94 RF0 H/L Special Int VOL 2.12 2ND TSP

+31.80 3RD TSP 9 62 05/94 RF0 Bobbin No!

0.31 12TH TSP 1.48 F/L 9 70 05/94 RF0 Bobbin NQI 0.67 4TH TSP

+6.49 F/L 05/94 RF0 H/L Special Int VOL 0.34 4TH TSP

+6.14 4TH TSP 9 73 05/94 RF0 Bobbin ADI 2.46 10TH TSP

+36.58 F/L 05/94 RF0 C/L Special Int VOL 0.33 9TH TSP

-9.02 97H TSP 9 80 05/94 RF0 Bobbin ADI 2.91 1ST TSP

+19.59 F/L 9 81 05/94 RF0 Bobbin 001 4

1.0718TH TSP

+11.19 F/L i

9 88 05/94 RF0 Bobbin ADI 2.43 2ND TSP

+2.80 F/L 05/94 RF0 H/L Special Int VOL 0.23 2ND TSP

+3.23 2ND TSP 9 89 05/94 RF0 Bobbin No!

0.74 13TH U P

+19.64 F/L 05/94 RF0 C/L Special Int VOL 0.61 13TH TSP

+20.27 13fH TSP 9 93 05/94 RF0 Bobbin ODI 9

0.3714TH TSP

+13.18 F/L 9 95 05/94 RF0 Bobbin NQI 0.67 7TH TSP

+25.08 F/L 05/94 RF0 Bobbin ADI 1.23 10TH TSP

+27.23 F/L 05/94 RF0 C/L Special Int VOL 0.67 10TH TSP

+27.23 10TH TSP 9 96 05/94 RF0 Bobbin ADI 1.51 7TH TSP

+32.95 F/L 05/94 RF0 Bobbin No!

0.77 4TH TSP

+38.11 F/L 05/94 RF0 Bobbin 001 24 0.75 7TH TSP

+32.05 F/L 05/94 RF0 H/L Special Int VOL 6.44 STM TSP

-4.82 STH TSP 9 99 05/94 RF0 Bobbin ADI 8.30 BTH TSP 5.15 F/L 05/94 RF0 U-Bend VOL 1.01 BTH TSP

+5.98 1AVB 9 100 05/94 RF0 Bobbin Nol 0.93 4AVB

-3. 73 F/L 1

1

BWNS TUBAN 11 (Version 2.0) 06/16/1994 14:17:53 aseeeeeeeeeeeeeee***********

Catawba Nuclear Station - Unit Two eeeeeeee********************

S/G A 05/94 RF0 Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U-Bend Page 7 of 32 S/G A - ATTACHMENT #1 INDICATIONS OF IMPERFECTIONS RDW COL QUTAGE TEST TYPE

'ND %TW VOLTS LOCATION EXTENT 1 05/94 RF0 Bobbin ADI 0.50 13TH TSP

+25.77 F/L 05/94 RF0 U Bend VOL t 96 4AVB

-3.64 97H TSP 05/94 RF0 C/L Special Int VOL 0.28 13fH TSF

+24.42 13TH TSP 05/94 RF0 C/L Special Int VOL 0.54 13fH TSP

+25.77 13fH TSP 9 102 05/94 RF0 Bobbin ADI 2.19 STH TSP

+7.42 F/L 05/94 RFO H/L Special Int VOL 0.37 STH TSP

+6.60 STH TSP 9 105 05/94 RF0 Bobbin ADI 2.07 7TH TSP

+10.92 F/L 05/94 RF0 H/L Special Int VOL 0.47 7TH TSP

+14.82 7TH TSP 05/94 R.'O H/L Special Int VOL 0.67 7TH TSP

+11.04 7TH TSP 9 106 05/94 RF0 Bobbin DDI 16 2.22 11TH TSP

+15.98 F/L 9 109 05/94 RF0 Bobbin NQ1 0.34 10TH TSP

+22.90 F/L 05/94 RF0 C/L Special Int VOL 0.87 10TH TSP

+22.58 10TH TSP 9 112 05/94 RF0 Bobbin 001 7

0.55 77H TSP

+30.23 F/L 10 12 05/94 RF0 Bobbin 001 25 2.10 7TH TSP

+6.99 F/L 05/94 RF0 H/L Special Int VOL 1.02 7TH TSP

+7.87 TTH TSP 10 14 05/94 RF0 Bobbin ADI 5.64 3RD TSP

+6.77 F/L 05/94 RF0 Bobbin 001 17 3.49 3RD TSP

-1.00 F/L 05/94 RF0 Bobbin 001 18 3.59 3RD TSP

+8.34 F/L 05/94 RF0 H/L Special Int VOL 0.66 3RD TSP

+7.77 3RD TSP 05/94 RF0 H/L Special int VOL 1.04 3RD TSP

-0.77 3RD TSP 05/94 RF0 H/L Special Int VOL 1.08 3RD TSP

+9.46 3RD TSP 05/94 RF0 H/L Special Int VOL 1.18 3RD TSP 8.79 3RD TSP 10 17 05/94 RF0 Bobbin ADI 8.15 11TH TSP

+22.33 F/L 05/94 RF0 C/L Special Int VOL 0.92 11TH TSP

+22.80 11TH TSP 10 19 05/94 RF0 Bobbin ODI 21 2.11 11TH ISP

+13.56 F/L 10 26 05/94 RF0 Bobbin ADI 2.73 STH TSP

+8.49 F/L 05/94 RF0 H/L Special Int VOL 0.81 STH TSP

+8.57 6TH TSP 10 41 05/94 RF0 Bobbin ADI 2.24 1ST TSP

+21.63 F/L 10 50 05/94 RF0 Bobbin ADI 3.76 71H TSP

+20.12 F/L 05/94 RFO Bobbin ADI 4.90 STH TSP

+28.74 F/L 05/94 RFC Bobbin 001 12 3.05 1ST TSP

+23.88 F/L 05/94 RF0 Bobbin 001 24 1.96 4TH TSP

+37.38 F/L 05/94 RF0 H/L Special Int VOL 1.39 STH TSP

+29.81 6TH TSP 10 59 05/94 RF0 Bobbin DDI 9

2.14 13TH TSP

+32.66 F/L 05/94 RF0 Bobbin ODI 20 0.98 16TH TSP

+2.97 F/L 10 61 05/94 RFO Bobbin NQ1 0.59 1ST TSP

+10.96 F/L 05/94 RF0 H/L Special Int VOL 0.94 1ST TSP

+11.42 1ST TSP 10 66 05/94 RF0 Bobbin 001 3

1.06 10TH TSP

+36.86 F/L 1

10 70 05/94 RF0 Bobbin 001 20 1.95 3RD TSP

+8.47 F/L 05/94 RF0 Bobbin 001 23 1.43 3RD TSP

+12.20 F/L 10 75 05/94 RFO Bobbin ADI 2.46 171H TSP

-1.22 F/L 05/94 RF0 C/L Special Int VOL 0.51 177H TSP

-1.42 17TH TSP 10 77 05/94 RF0 Bobbin 001 21 0.80 7TH TSP

+30.32 F/L 10 80 05/94 RF0 Bobbin 001 5

0.53 15TH TSP

+11.06 F/L 10 81 05/94 RF0 Bobbin 001 6

0.72 3RD TSP

+20.65 F/L 05/94 RF0 Bobbin 001 9

1.28 16TH TSP

+2.39 F/L 10 82 05/94 RF0 Bobbin 001 14 1.92 137H TSP

+11.97 F/L 05/94 RF0 Bobbin 001 23 3.24 15TH TSP

+15.70 F/L i

10 85 05/94 RF0 Bobbin 001 26 2.12 12TH TSP

+16. 75 F/L 10 88 05/94 RF0 Bobbin 001 7

1.21 11TH TSP

+ 7.55 F/L 10 89 05/94 RF0 Bobbin 001 12 0.47 13TH TSP

+22.85 F/L 10 91 05/94 RF0 Bobbin NQ1 0.59 STH TSP

+20.21 F/L 05/94 RF0 Bobbin 001 17 0.91 10TH TSP

+42.44 F/L 05/94 RF0 Bobbin 001 29 0.87 13fH TSP

+17.00 F/L 05/94 RF0 C/L Special Int VOL 0.97 9TH TSP 2.62 9TH TSP 05/94 RF0 C/L Special Int VOL 2.17 9TH TSP

-7.93 9TH TSP 05/94 RF0 H/L Special Int VOL 0.39 STH TSP

+18.79 STH TSP 05/94 RF0 C/L Special' Int VOL 0.76 13TH TSP

+17.00 13TH TSP 10 92 05/94 RF0 Bobbin 001 7

1.40 9TH TSP

-1.01 F/L 05/94 RF0 C/L Special Int VOL 0.74 97H TSP

-0.92 97H TSP 10 95 05/94 RF0 Bobbin ADI 1.32 7TH TSP

+28.00 F/L 05/94 RF0 Bobbin ADI 2.80 9TH TSP

-1.75 F/L 05/94 RF0 Bobbin NQI 0.52 7TH TSP

+27.29 F/L 05/94 RF0 Bobbin 001 9

0.79 10TH TSP

+42.97 F/L 05/94 RF0 C/L Special Int VOL 0.44 9TH TSP

-3.25 97H TSP 05/94 RF0 C/L Special Int VOL 1.07 9TH TSP 1. 75 9TH TSP

ene*************************

BWNS TUBAN !! (Version 2.0) 06/16/1994 14:17:53 eeeeeeeeeeeee***e***********

Catawba Nuclear Station - Unit Two

      • e*******e.eee*ee********e eeeeeee*****e************e..

gfg g ee** ee

....e**....e********

05/94 RF0 Bobbin,C/L Special Interest,N/L Special Interest,H/L Tubesheet,U-Bend Page 8 of 32 S/G A - ATTACHMENT #1 INDICATIONS OF IMPERFECTIONS ROW COL DUTAGE TEST TYPE IND %TW VOLTS LOCATION EXTENT 1 10 99 05/94 RF0 Bobbin ADI 5.41 4TH TSP

+ 27.19 F/L 05/94 RF0 H/L Special Int VOL 1.02 4TH TSP

+25.78 4TH TSP 05/94 RF0 H/L Special Int VOL 1.32 4TH TSP

+22.64 4TH TSP 05/94 RF0 H/L Spectat Int VOL 1.54 4TH TSP

+28.23 4TH TSP 10 108 05/94 RF0 Bobbin ADI 4.01 2ND TSP

+32.42 F/L 05/94 RF0 H/L Special Int VOL 0.55 3RD TSP

-3.35 3RD TSP 10 110 05/94 RF0 Bobbin ADI 6.69 191H TSP

+ 7. 73 F/L 10 111 05/94 RF0 Bobbin No!

0.58 10TH TSP

+34.50 F/L 05/94 RF0 C/L Special Int VOL 0.32 9TH TSP

-11.12 9TH TSP 05/94 RF0 C/L Special Int VOL 0.62 9TH TSP

-3.96 9TH TSP 10 112 05/94 RF0 Bobbin 001 20 1.53 10TH TSP

+44.98 F/L 11 4 05/94 RF0 Bobbin ADI 4.4015f H TSP

+4.77 F/L 05/94 RF0 C/L Special Int VOL 1.23 15TH TSP

+4.85 15TH TSP 11 5 05/94 RF0 Bobbin NQI 0.66 7TH TSP

+14.77 F/L 05/94 RF0 Bobbin No!

0.74 10TH TSP

+19.16 F/L 05/94 RF0 H/L Special Int VOL 0.95 7TH TSP

+15.63 7TH TSP 11 16 05/94 RF0 Bobbin No!

0.38 7TH TSP

+30.77 F/L 05/94 RF0 Bobbin 001 26 1.02 10TH TSP

+31.27 F/L 05/94 RF0 C/L Special Int VOL 0.27 9TH TSP

-14.58 9TH TSP 11 28 05/94 RF0 Bobbin ADI 4.45 TTS-CL

+5.61 F/L 05/94 RF0 Bobbin ADI 5.07 TTS-CL

+2.84 F/L 05/94 RF0 C/L Special Int VOL 0.22 TTS-CL

+5.44 197H TSP 05/94 RF0 C/L Special Int VOL 0.39 TTS-CL

+2.39 197H TSP 11 30 05/94 RF0 Bobbin 001 16 3.53 14TH TSP

+15.94 F/L 05/94 RF0 Bobbin 001 25 3.54 14TH TSP

+14.23 F/L 11 51 05/94 RF0 Bobbin 001 27 2.39 2ND TSP

+25.12 F/L 11 54 05/94 RF0 Bobbin ADI 3.90 15TH TSP

+3.02 F/L 11 65 05/94 RF0 Bobbin 001 1

0.77 3RD TSP

+5.99 F/L 05/94 RF0 Bobbin 001 7

1.02 13fH TSP

+14.66 F/L 11 87 05/94 RF0 Bobbin ADI 2.16 17TH TSP

+3.64 F/L 05/94 RF0 C/L Special Int VOL 0.47 17TH TSP

+3.65 17TH TSP 11 88 05/94 RF0 Bobbin 001 3

0.58 13TH TSP

+22.18 F/L 11 102 05/94 RF0 Bobbin 001 14 1.62 2ND TSP

+24.24 F/L 11 106 05/94 RF0 Bobbin 001 20 0.49 7TH TSP

+30.57 F/L 11 110 05/94 RF0 Bobbin ODI 2

0.69 10TH TSP

+36.74 F/L 11 111 05/94 RF0 Bobbin ODI 17 1.11 10TH TSP

+39.62 F/L 05/94 RF0 C/L Special Int VOL 1.46 97H TSP

-4.87 91H TSP 11 112 05/94 RF0 Bobbin ODI 22 1.57 8TH TSP

-1.16 F/L 05/94 RF0 H/L Special Int VOL 1.22 BTH TSP

-1.16 8TH TSP 12 2 05/94 RF0 Bobbin 001 2

0.55 11TH TSP

+26.66 F/L 12 10 05/94 RF0 Bobbin 001 29 1.71 2ND TSP

-3.44 F/L 12 13 05/94 RF0 Bobbin ADI 9.70 TTS CL

+4.97 F/L 05/94 RF0 C/L Special Int VOL 1.11 TTS-CL

+4.44 TTS HL 12 18 05/94 RF0 Bobbin ADI 1.21 9TH TSP

-6.44 F/L 12 19 05/94 RF0 Bobbin ADI 9.21 9TH TSP

-7.60 F/L 05/94 RF0 Bobbin No!

0 B4 10TH TSP

+27.80 F/L 05/94 RF0 Bobbin No!

0.95 10TH TSP

+25.12 F/L 05/94 RF0 Bobbin 001 16 0.75 Tr ???

+22.23 F/L 05/94 RF0 C/L Special Int VOL 0.42 frH TSP

-16.70 9TH TSP 05/94 RF0 C/L Special Int VOL L.br YTH TSP

-8.79 97H TSP 05/94 RF0 C/L Speclat Int VOL 3.45 97H TSP

-7.74 91H TSP 12 23 05/94 RF0 Bobbin DDI if 0.59 77H TSP

+24.53 F/L 05/94 RF0 Bobbin ODI is 4 46 7TH TSP

+23.90 F/L 05/94 RF0 Bobbin 001 16 6.?* S"H TSP

+22.18 F/L 05/94 RF0 Bobbin 0D1 11 1.0F 1CrH TSP

+22.92 F/L 05/94 RF0 Bobbin ODI 24 1.13 ib.1 TSP

+26.94 F/L 05/94 RF0 H/L Special Int VOL 0.45 7TH TSP

+36.00 71H TSP 05/94 RF0 H/L Special Int VOL 0.47 7TH TSP

+38.04 7TH TSP 05/94 RF0 H/L Special Int VOL 0.55 7TH TSP

+38.B4 77H TSP 12 24 05/94 RFO Bobbin ADI 3.19 6TH TSP

-5.10 F/L 05/94 RF0 Bobbin ADI 4.67 2ND TSP

+18.43 F/L 05/94 RF0 H/L Special Int VOL 1.00 2ND TSP

+20.60 3RD TSP 12 33 05/94 RF0 Bobbin ADI 5.01 12TH TSP

-8.46 F/L 05/94 RF0 C/L Special Int VOL 0.2712TH TSP

-11.03 12TH TSP 05/94 RF0 C/L Special Int VOL 0.87 12TH TSP

-9.51 12TH TSP 12 37 05/94 RF0 Bobbin DDI 22 0.64 14TH TSP

+10.37 F/L

eeeeeee*********************

BWNS TUBAN !! (Version 2.0) 06/16/1994 14:17:53 ee***eeeeeeeeeeeeeeeeeeeeeee Catawba Nuclear Station - Unit Two eseeeeeeeee****** *******,*.

gjg g ee**eeee**..**.**. ********

05/94 RF0 Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U-Beid Page 9 of 32 S/G A - ATTACHMENT #1 INDICATIONS CF IMPERFECTIONS ROW COL DUTAGE TEST TYPE IND %TW VOLTS LOCATION EXTENT 1 12 48 05/94 RFO Bobbin 001 10 0.74 10TH TSP

+39.08 F/L 12 52 05/94 RF0 Bobbin NQI 1.2710TH TSP

+23.32 F/L 05/94 RF0 Bobbin 001 13 0.78 10TH TSP

+31.31 F/L 05/94 RF0 C/L Special Int VOL 2.48 10TH TSP

+22.61 10TH TSP 12 55 05/94 RF0 Bobbin 001 29 0.91 11TH TSP

+15.90 F/L 12 89 05/94 RF0 Bobbin ADI a.82 STH TSP

+16.34 F/L 05/94 RFO Bobbin 001 13 2.18 7TH TSP

+13.56 F/L 05/94 RF0 H/L Special Int VOL 1.64 STH TSP

+17.87 STH TSP 12 90 05/94 RF0 Bobbin ADI 4.38 7TH TSP

+20.79 F/L 05/94 RF0 Bobbin ADI 4.97 6TH TSP

+8.40 F/L 05/94 RF0 H/L Special Int VOL 0.18 BTH TSP

-10.70 BTH TSP i

05/94 RF0 H/L Special Int VOL 0.36 BTH TSP

-7.24 BTH TSP 05/94 RF0 H/L Special Int VOL 0.38 8TH TSP

-21.85 BTH TSP 05/94 RF0 H/L Special Int VOL 0.63 6TH TSP

+8.52 6TH TSP 05/94 RF0 H/L Special Int VOL 0.63 BTH TSP

-3.53 BTH TSP 05/94 RFO H/L Special Int VOL 0.70 8TH TSP

-9.48 8TH TSP 05/94 RF0 H/L Special Int VOL 0.78 6TH TSP

+9.15 6TH TSP 12 94 05/94 RF0 Bobbin 001 10 1.13 3RD TSP

+7.84 F/L 12 108 05/94 RF0 Bobbin NQI 0.86 STH TSP

+28.15 F/L 05/94 RF0 Bobbin 001 11 3.82 13TH TSP

+34.21 F/L 05/94 RF0 H/L Special Int VOL 0.55 6TH TSP

-14.58 6TH TSP 12 113 05/94 RFO Bobbin DDI 16 0.90 9TH TSP

-0.71 F/L 13 3 05/94 RF0 Bobbin ADI 4.95 3RD TSP

+21.53 F/L 05/94 RF0 H/L Special Int VOL 0.23 3RD TSP

+20.52 3RD TSP 13 4 05/94 RF0 Bobbin ADI 4.44 2ND TSP

+20.21 F/L 05/94 RF0 H/L Special Int VOL 0.94 2ND TSP

+19.26 2ND TSP 13 7 05/94 RF0 Bobbin ADI 2.82 12TH TSP

+2.49 F/L 05/94 RF0 C/L Special Int VOL 0.24 12TH TSP

+2.71 12TH TSP 13 11 05/94 RF0 Bobbin ADI 4.71 18TH TSP

+5.24 F/L 05/94 RF0 C/L Special Int VOL 0.72 18TH TSP

+5.22 18TH TSP 13 14 05/94 RF0 Bobbin ADI 3.76 13TH ISP

+38.62 F/L 05/94 RF0 C/L Special Int VOL 0.45 12TH TSP

-4.54 12TH TSP 13 17 05/94 RF0 Bobbin 001 4

0.36 9TH TSP

-5.92 F/L 13 21 05/94 RF0 Bobbin ADI 6.91 7TH TSP

+33.73 F/L 05/94 RF0 H/L Special Int VOL 1.25 STH TSP 10.47 BTH TSP 13 29 05/94 RF0 Bobbin ADI 1,69 7TH TSP

+10.14 F/L 05/94 RF0 Bobbin NQI 0.57 7TH TSP

+9.28 F/L 05/94 RFO H/L Special Int VOL 0.86 TTH TSP

+10.02 BTH TSP 05/94 RF0 H/L Special Int VOL 1.66 77H TSP

+11.24 8TH TSP 13 33 05/94 RF0 Bobbin ADI 6.78 7TH TSP

+17.56 F/L 05/94 RF0 H/L Special Int VOL 0.85 7TH TSP

+19.01 7TH TSP 13 34 05/94 RF0 Sobbin ADI 5.10 12id TSP

+18.37 F/L 05/94 RF0 Bobbin ADI 7.82 197H TSP

+4.86 F/L 05/94 RF0 Bobbin ADI 9.82171H TSP

+13.07 F/L 05/94 RF0 Bobbin No!

0.72 13TH TSP

+5.71 F/L 05/94 RF0 C/L Special Int VOL 0.65 19TH TSP

+4.37 18TH TSP 05/94 RF0 C/L Special Int VOL 0.69 12TH TSP

+18.15 12TH TSP 05/94 RFC C/L Special Int VOL 0.81 12TH TSP

+35.81 12TH TSP 05/94 RF0 C/L Special Int VOL 1.09 13TH TSP

+3.70 13TH TSP 05/94 RF0 C/L Special Int VOL 1.26 17TH TSP

+13.16 17TH TSP 13 40 0*f94 RF0 Bobbin ADI 4.58 12TH TSP

+34.B4 F/L 05/94 RF0 C/L Special Int VOL 0.47 11TH TSP

-7.99 11TH TSP 13 43 05/94 RF0 Bobbin ADI 6.77 STH TSP

+33.85 F/L 05/94 RF0 H/L Special Int VOL 0.83 6TH TSP

-8.94 6TH TSP 05/94 RF0 H/L Special Int VOL 0.88 6TH TSP

-7.20 6TH TSP 05/94 RF0 H/L Special Int VOL 1.35 6TH TSP

-10.19 6TH TSP 13 44 05/94 RF0 Bobbin ADI 4.34 STH TSP

-7.20 F/L 05/94 RF0 H/L Special Int VOL 1.22 STH TSP

-7.74 5TH TSP 13 47 05/94 RFO Bobbin ADI 5.09 181H TSP

-4.94 F/L 05/94 RF0 C/L Special Int VOL 0.50 19TH TSP

+5.08 18TH TSP 13 74 05/94 RF0 Bobbin ADI 6.18 7TH TSP

+13.70 to +17.35 F/L 05/94 RF0 H/L Special Int VOL 0.60 7TH TSP

+7.67 TTH TSP 05/94 RF0 H/L Special Int VOL 0.63 71H TSP

+15.40 7TH TSP 05/94 RF0 H/L Special Int VOL 0.88 7TH TSP

+30.91 7TH TSP 13 76 05/94 RF0 Bobbin ADI 5.14 4AVB

-3.04 F/L 05/94 RF0 Bobbin ADI 3.23 7TH TSP

+9.13 F/L l

1

eeeeeeeeeeee****************

BWNS TUBAN 11 (Version 2.0) 06/16/1994 14:17:53 eeeeeeeeeeeee***************

Catawba Nuclear Station - Unit Two esese.......................

5ja g 05/94 RF0 eeee************************

Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U Bend Page 10 of 32 S/G A - ATTACHMENT #1 INDICAfl0NS OF IMPERFECTIONS ROW COL QUTAGE TEST T &E IND %TW VOLTS LOCATION EXTENT 1 05/94 RF0 U-Bend VOL 0.56 4AVB

-3.31 97H TSP 05/94 RF0 Bobbin ODI 8

2.07 10TH TSP

+38.19 F/L 05/94 RF0 H/L Special Int VOL 1.07 71H TSP

+9.31 BTH TSP 05/94 RF0 N/L Special Int VOL 1.22 77H TSP

+7.70 BTH TSP 13 77 05/94 RF0 Bobbin 001 5

1.64 12TH TSP

+29.44 F/L 13 87 05/94 RF0 Bobbin ADI 2.92 6TH TSP

+25.22 F/L 05/94 RF0 Bobbin ADI 6.19 7TH TSP

+6.61 F/L 05/94 RF0 Bobbin ADI 6.33 7TH TSP

+20.40 F/L 05/94 RF0 H/L Special Int VOL 0,46 7TH TSP

-14.10 TTH TSP 05/94 RF0 H/L Special int VOL 0.71 7TH TSP

-15.72 TTH TSP 05/94 RF0 H/L Special Int VOL 0.85 7TH TSP

+20.56 7TH TSP 05/94 RF0 H/L Special Int VOL 0.96 TTH TSP

+6.53 7TH TSP 05/94 RF0 H/L Special Int VOL 1.56 7TH TSP

+19.35 7TH TSP 13 95 05/94 RF0 Bobbin ADI 3.47 4TH TSP

+25.99 F/L 05/94 RF0 H/L Special Int VOL 0.35 4TH TSP

+17.90 4TH TSP 05/94 RF0 H/L Special Int VOL 0.71 4TH TSP

+24.50 4TH TSP 13 98 05/94 RF0 Bobbin ADI 2.29 4TH TSP

+26.97 F/L 05/94 RF0 H/L Special Int VOL 0.96 4TH TSP

+25.38 4TH TSP 13 108 05/94 RF0 Bobbin 001 13 1.24 10TH TSP

+25.18 F/L 14 16 05/94 RF0 Bobbin NOI 0.27 7TH TSP

+36.80 F/L 05/94 RF0 Bobbin NQI 0.32 7TH TSP

+34.62 F/L 05/94 RF0 Bobbin NQ1 0.34 7TH TSP

+39.35 F/L 14 17 05/94 RF0 Bobbin ADI 4.52 3RD TSP

+24.00 F/L 05/94 RF0 Bobbin No!

0.22 TTH TSP

+30.36 F/L 05/94 RF0 N/L Special Int VOL 0.23 3RD TSP

+22.70 3RD TSP 14 19 05/94 RF0 Bobbin 001 7

0.43 14TH TSP

+12.69 F/L 14 25 05/94 RF0 Bobbin NQI 1.34 137H TSP

+11.72 F/L 05/94 RTO Bobbin 001 13 1.39 15TH TSP

+1.50 F/L 05/94 RFO Bobbin 001 14 1.38 10TH TSP

+3.57 F/L 05/94 RF0 Bobbin 001 25 1.82 16TH TSP

+1.57 F/L 05/94 RF0 C/L Special Int VOL 0.36 13TH TSP

+11.55 13TH TSP 05/94 RF0 C/L Special Int VOL 0.5715TH TSP

+1.79 15TH TSP 05/94 RF0 C/L Special Int VOL 0.66 10TH TSP

+3.28 10TH TSP 05/94 RF0 C/L Special Int VOL 0.67 16TH TSP

+1.22 15TH TSP 14 28 05/94 RF0 Bobbin ADI 2.89 15TH TSP

+15.57 F/L 05/94 RF0 Bobbin ADI 4.00 10TH TSP

+18.37 F/L 05/94 RF0 C/L Special Int VOL 0.41 15TH TSP

+15.57 14TH TSP 05/94 RF0 C/L Special Int VOL 0.51 15TH TSP

-2.44 14TH TSP 05/94 RF0 C/L Special Int VOL 0.53 10TH TSP

+16.30 10TH TSP 14 29 05/94 RF0 Bobbin 001 19 1.95 6TH TSP

+21.43 F/L 14 33 05/94 RFO Bobbin 001 11 0.59 10TH TSP

+41.09 F/L 14 35 05/94 RF0 Bobbin ADI 4.59 2ND TSP

+26.05 F/L 05/94 RF0 H/L Special Int VOL 0.39 3RD TSP

-9.82 3RD TSP 14 45 05/94 RF0 Bobbin ODI 21 0.40 10TH TSP

+40.79 F/L 14 49 05/94 RF0 Bobbin ADI 1.1710TH TSP

+33.92 F/L 05/94 RF0 Bobbin NOI 0.32 10TH TSP

+32.59 F/L 14 60 05/94 RF0 Bobbin ADI 2.94 11TH TSP

+4.60 F/L 05/94 RF0 C/L Special Int YOL 1.31 11TH TfP

+4.60 11TH TSP 14 68 05/94 RF0 Bobbin ADI 2.46 TTS-HL

+3.88 F/L 14 83 05/94 RF0 Bobbin ADI 3.38 3RD TSP

+22.49 F/L 05/94 RF0 Bobbin 001 20 1.49 3RD TSP

+13.36 F/L 05/94 RF0 N/L Special Int VOL 0.48 3RD TSP

+11.94 3RD TSP 05/94 RF0 N/L Special Int VOL 0.50 3RD TSP

+21.30 3RD TSP 05/94 RF0 H/L Special Int VOL 0.61 3RD TSa

+12.81 3RD TSP 14 88 05/94 RF0 Bobbin 001 18 1,82 17TH 1 9

+13.65 F/L 05/94 RF0 Bobbin ODI 18 2.00177H TSP

+10.67 F/L 14 97 05/94 RF0 Bobbin NQ1 1.0512TH TSP

+37.58 F/L 05/94 RFO Bobbin 001 14 2.43 12TH TSP

+31.35 F/L 05/94 RF0 C/L Special Int VOL 0.42 11TH TSP

-5.74 11TH TSP 05/94 RF0 C/L Special Int VOL 0.47 lith TSP

-12.39 11TH TSP 14 98 05/94 RF0 Bobbin 001 8

1.03 7TH TSP

+30.95 F/L 14 100 05/94 RF0 Bobbin ADI 9.51 1AVB

+17.37 F/L 05/94 RF0 U-Bend VOL 1.53 1AVB

+16.95 4AVB 14 103 05/94 RF0 Bobbin ADI 3.01 12TH TSP

+13.71 F/L 05/94 RF0 Bobbin ADI 3.96 12TH TSP

+15.45 F/L 05/94 RF0 C/L Special Int VOL 0.33 12TH TSP

+15.76 12TH TSP

BWNS TUBAN 11 (Version 2.0) 06/16/i994 14:17:53 Catawba Nuclear Station - Unit Two

.e..**.....................

Sfg a 05/94 RF0 Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U Bend b

Page 11 of 32 S/G A - ATTACHMENT #1 INDICATIONS OF IMPERFECTIONS RDW COL DUTAGE TEST TYPE IND %TW VOLTS LOCAT!DN EXTENT 1 05/94 RF0 C/L Special Int VOL 0.61 12TH TSP

+13.66 12TH TSP 14 105 05/94 RF0 Bobbin ADI 5.02 6TH TSP

+38.28 F/L 05/94 RF0 H/L Spectat Int VOL 0.66 TTH TSP

-1.35 7TH TSP 05/94 RF0 H/L Special Int VOL 0.71 7TH TSP

-4.24 7TH TSP 05/94 RF0 H/L Special Int VOL 0.92 7TH TSP

-4.18 7TH TSP 14 107 05/94 RF0 Bobbin NQI 0.65 10TH TSP

+40.04 F/L 05/94 RF0 Bobbin DDI 17 0.99 7TH TSP

+35.68 F/L 05/94 RF0 C/L Special Int VOL 0.73 9TH TSP

-4.97 9fH TSP 14 108 05/94 RF0 Bobbin 001 8

1.49 6TH TSP

+13.06 F/L 14 111 05/94 RF0 Bcbbin ODI 29 0.69 10Th TSP

+35.10 F/L 05/94 RF0 C/L Special Int VOL 0.42 9T3 TSP

-10.62 9TH TSP 15 3 05/94 RFU Bobbin NQ1 0.47 7TH TSP

+14.25 F/L 05/94 RF0 H/L Special Int VOL 0.52 7TH TSP

+13.11 7TH TSP 15 7 05/94 RF0 Bobbin 001 30 0.62 6TH TSP

+22.58 F/L 15 14 05/94 RF0 Bobbin No!

0.38 10TH TSP

+42.47 F/L 15 17 05/94 RF0 Bobbin 001 11 0.63 10TH TSP

+26.91 F/L 15 18 05/94 RF0 Bobbin ADI 0.53 10TH TSP

+43.65 F/L 05/94 RF0 Bobbin 001 13 0.79 7TH TSP

+30.14 F/L 05/94 RF0 Bobbin 001 10 0.52 10TH TSP

+35.93 F/L 15 22 05/94 RF0 Bobbin ODI 16 0.53 11TH TSP

+19.65 F/L 15 23 05/94 RF0 Bobbin 001 12 1.03 10TH TSP

+24.02 F/L 15 24 05/94 RF0 Bobbin No!

0.48 7TH TSP

+26.14 F/L 05/94 RF0 Bobbin 001 23 0.81 TTS-CL

+5.35 F/L 05/94 RF0 Bobbin 001 2

0.79 7TH TSP

+21.21 F/L 05/94 RF0 Bobbin DDI 17 0.40 7TH TSP

+25.21 F/L 05/94 RF0 Bobbin 001 18 0.88 10TH TSP

+42.95 F/L 05/94 RF0 Bobbin 001 13 1.23 10TH TSP

+5.20 F/L 05/94 RF0 H/L Special Int VOL 0.45 TTH TSP

+21.50 7TH TSP 05/94 RF0 C/L Special Int VOL 0.89 10TH TSP

+4.97 9TH TSP 05/94 RF0 C/L Special Int VOL 1,46 10TH TSP

+40.99 9TH TSP 05/94 RF0 C/L Special Int VOL 1,56 10TH TSP

+6.60 97H TSP 15 25 05/94 RF0 Bobbin 001 6

1.39 177H TSP

+16.33 F/L 15 26 05/94 RF0 Bobbin NQI 0.57 7TH TSP

+38.30 F/L 05/94 RF0 H/L Special Int VOL 0.95 BTH TSP

-3.66 BTH TSP 05/94 RF0 H/L Special Int VOL 1.35 BTH TSP

-13.54 8TH TSP 05/94 RF0 H/L Special Int VOL 1.45 BTH TSP

-10.82 BTH TSP 05/94 RF0 H/L Special Int VOL 1.46 BTH TSP

-12.52 BTH TSP 15 27 05/94 RF0 Bobbin No!

0.51 TTS-CL

+2.94 F/L 05/94 RF0 C/L Special Int VOL 0.53 TTS CL

+2.94 TTS-HL 15 29 05/94 RF0 sobbin 001 8

0.55 7TH TSP

+38.31 F/L 05/94 RF0 H/L Specist Int VOL 1.54 BTH TSP

-2.82 BTH TSP 15 30 05/94 RF0 Bobbin ADI 1.12 13TH TSP

+29.68 F/L 05/94 RF0 Bobbin 001 1

1.80 77H TSP

+36.15 F/L 05/94 RF0 Bobbin 001 8

0.32 7TH TSP

+36.58 F/L 05/94 RF0 Bobbin 001 1

0.75 10TH TSP

+39.09 F/L 05/94 RF0 C/L Special Int VOL 0.42 12TH TSP

-10.97 12TH TSP 05/94 RF0 C/L Special Int VOL 0.43 12TH TSP

-12.14 12TH TSP 05/94 RF0 C/L Special Int VOL 0.5012TH TSP

-14.65 12TH TSP 05/94 RF0 C/L Special Int VOL 0.61 12TH TSP

-13.45 12TH TSP 15 31 05/94 RF0 Bobbin ODI 17 2.34 6TH TSP

+35.73 F/L 05/94 RF0 Bobbin 001 2

0.83 10TH TSP

+33. 73 F/L 15 49 05/94 RF0 Bobbin 001 22 1.53 2ND TSP

+17.22 F/L 15 50 05/94 RF0 Bobbin NQ1 0.44 10TH TSP

+20.29 F/L 15 51 05/94 RF0 Bobbin NOI 0.31 TTH TSP

+28.42 F/L 05/94 RF0 H/L Special Int VOL 1.28 BTH TSP

-14.88 BTH TSP 15 53 05/94 RF0 Bobbin 001 16 0.53 6TH TSP

+40.35 F/L 15 55 05/94 RF0 Bobbin ODI 19 2.84 17TH TSP

+9.21 F/L 15 56 05/94 RF0 Bobbin DDI 26 0.41 6TH TSP

+4.25 F/L 15 57 05/5 9F0 Bobbin DDI 11 1.1918TH TSP

+9.90 F/L 15 65 05/94 RF0 Bobbin A01 2.18 13TH TSP

+39.42 F/L 05/94 RF0 Bobbin ADI 2.79 10TH TSP

+14.70 F/L 05/94 RF0 Bobbin 001 10 0.78 10TH TSP

+15.61 F/L 05/94 RF0 C/L Special Int VOL 0.24 10TH TSP

+13.83 10TH TSP 05/94 RF0 C/L Special Int VOL 0.3710TH TSP

+12.91 10TH TSP 05/94 RF0 C/L Special Int VOL 0.62 10TH TSP

+15.61 10TH TSP 15 72 05/94 RF0 Bobbin ODI 12 1.05 11TH TSP

+4.78 F/L j

I BWNS TUBAN 11 (Version 2.0) 06/16/1994 14:17:53 Catawba Nuclear Station - Unit Two Sfg g 05/94 RF0 Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U-Bend Page 12 of 32 S/G A - ATTACHMENT #1 INDICATIONS OF IMPERFECTIONS ROW COL DUTAGE TEST TYPE IND %TW VOLTS LOCATION EkTENT1 15 74 05/94 RF0 Bobbin ADI 3.16 16TH TSP

+11.15 F/L 05/94 RF0 C/L special Int VOL 0.21 16TH TSP

+11.02 16TH TSP 15 80 05/94 RF0 Bobbin ADI 2.86 10TH TSP

+14.43 F/L 05/94 RF0 C/L Special Int VOL 0.43 10TH TSD

+13.28 10TH TSP 15 81 05/94 RF0 Bobbin NQI 0.74 4AVB

-1.54 F/L 15 85 05/94 RF0 Bobbin ODI 13 1.59 13TH TSP

+31.30 F/L t

05/94 RF0 Bobbin 001 17 1.50 14TH TSP

+15.06 F/L 05/94 RF0 Bobbin 001 18 0.95 11TH TSP

+27.98 F/L 15 87 05/94 RF0 Bobbin ADI 2.00 6TH TSP

+32.04 F/L 05/94 RF0 Bobbin ADI 3.69 13TH TSP

+27.06 F/L 05/94 RF0 C/L Special Int VOL 0.54 13fH TSP

+26.93 13TH TSP 15 BS 05/94 RF0 Bobbin ODI 2

0.71 10TH TSP

+37.97 F/L 15 91 05'94 RF0 Bobbin NQI 1.37 TTH TSP

+29.67 F/L 15 92 05/94 RF0 Bobbin AD!

5.60 4TH TSP

+38.18 F/L l

05/94 RF0 H/L Special Int VOL 1.53 STH TSP

-4.00 STH TSP 15 97 05/94 RF0 Bobbin ADI 1.88 12TH TSP

+30.48 F/L 05/94 RF0 Bobbin 001 13 0.76 7TH TSP

+38.13 F/L 05/94 RF0 C/L Special Int VOL 0.29 12TH TSP

+31.06 11TH TSP 15 100 05/94 RF0 Bobbin 001 38 1.22 6TH TSP

+34.21 F/L 05/94 RF0 H/L Special Int VOL 0.79 7TH TSP

-8.83 7TH TSP 15 105 05/94 RF0 Bobbin ADI 1.87 11TH TSP

+7.73 F/L i

05/94 RF0 C/L Special Int VOL 0.63 11TH TSP

+ 7. 27 11TH TSP 15 109 05/94 RF3 Bobbin 001 11 0.79 11TH TSP

+27.76 F/L 15 110 05/94 RF0 Bobbin ADI 4.71 8TH TSP

+11.18 F/L 05/94 RF0 U Bend VOL 0.65 8TH TSP

+11.26 1AVB 16 4 05/94 RF0 Bobbin ADI 4.92 'TH TSP

+26.56 F/L 05/94 RF0 Bobbin ADI 3.89 11TH TSP

+29.46 F/L 05/94 RF0 H/L Special Int VOL 0.71 7TH TSP

+25.03 TTH TSP 05/94 RF0 C/L Special Int VOL 0.54 10TH TSP 14.13 10TH TSP 16 5 05/94 RF0 Bobbin ODI 9

0.85 11TH TSP

+25.77 F/L 16 17 05/94 RF0 Bobbin NQI 0.54 10TH TSP

+24.80 F/L 05/94 RF0 C/L Special Int VOL 1.22 10TH TSP

+24.51 10TH TSP 16 23 05/94 RF0 Bobbin ADI 5.43 13TH TSP

+15.07 F/L 05/94 RF0 C/L Special Int VOL 1.14 13TH TSP

+14.97 13TH TSP 16 42 05/94 RF0 Bobbin ADI 3.41 12TH TSP

+34.28 F/L 05/94 RF0 C/L Special Int VOL 0.56 11TH TSP

-9.01 11TH TSP 16 51 05/94 RF0 Bobbin DDI 28 2.34 12TH TSP

+28.28 F/L 05/94 RF0 C/L Special Int VOL 0.89 12TH TSP + 2 7. 72 12TH TSP 16 60 05/94 RF0 Bobbin ADI 4.00 3RD TSP

-3.00 F/L 05/94 RF0 Bobbin ADI 2.71 13TH TSP

+16.96 F/L 05/94 RF0 Bobbin 001 34 1.33 13TH TSP

+20.62 F/L 05/94 RF0 Bobbin 001 39 0.93 18TH TSP

+10.65 F/L 05/94 RF0 H/L Special Int VOL 0.37 3RD TSP

-2.93 3RD TSP 05/94 RF0 C/L Special Int VOL 0.20 13TH TSP

+13.20 13fH TSP 05/94 RF0 C/L Special Int VOL 0.34 13TH TSP

+14.64 13fH TSP 05/94 RF0 C/L Special Int VOL 0.34 13TH TSP

+15.82 13TH TSP 05/94 RF0 C/L Special Int VOL 0.53 18TH TSP

+9.76 1BTH TSP 16 61 05/94 RF0 Bobbin 001 13 1.7417TH TSP

+4.44 F/L 16 62 05/94 RF0 Bobbin ADI 6.65 1ST TSP

+4.13 F/L 05/94 RF0 H/L Special Int VOL 1.47 1ST TSP

+4.63 1ST TSP 16 64 05/94 RF0 Bobbin 001 26 2.19 18TH Tip

+14.85 F/L 16 72 05/94 RF0 Bobbin IDI 40 62.79 TTS-HL

-0.17 F/L 16 77 05/94 RF0 Bobbin DDI 33 0.62 16TH TSP

+11.46 F/L 16 PS 05/94 RF0 Bobbin 001 36 0.90 2ND TSP

+6.69 F/L 05/94 RF0 H/L Special Int VOL 1.28 2ND TSP

+6.67 2ND TSP 16 94 05/94 RF0 Bobbin ADI 0.69 8TH TSP

-3.55 F/L 16 105 05/94 RF0 Bobbin DDI 24 3.05 7TH TSo

+9.53 F/L 16 106 05/94 RF0 Bobbin 001 23 1.14 16TH TSP 10.56 F/L 05/94 RF0 Bobbin 001 37 1.06 10TH TSP

+20.53 F/L 05/94 RF0 C/L Special Int VOL 0.30 10TH TSP

+19.62 10TH TSP 16 111 05/94 RF0 Bobbin 001 13 1.13 7TH TSP

+26.72 F/L 05/94 RF0 Bobbin 001 19 0.68 7TH TSP

+25.82 F/L 05/94 RF0 H/L Special Int VOL 1.22 BTH TSP

-16.13 BTH TSP 05/94 RF0 H/L Special Int VOL 1.42 8TH TSP

-14.08 BTH TSP 05/94 RF0 H/L Special Int VOL 1.43 BTH TSP

-17.16 BTH TSP 05/94 RF0 H/L Special Int VOL 2.46 BTH TSP

-15.18 BTH TSP

l i

BWNS TUBAN II (Version 2.0) 06/16/1994 14:17:53

  • eeeeeeeeeeee.....eeee.. ***

Catawba Nuclear Station

  • Unit Two

]

Sfg a 05/94 RF0 Bobbin,C/L Special Interest.H/L Special Interest,H/L Tubesheet,U Bend eeeeee**.

  • ............t****

l Page 13 of 32 S/G A - ATTACHMENT #1 INDICATIONS OF IMPERFECTIONS RDW COL DUTA0E TEST TYPE IND %TW VOLTS LOCATION EXTENT 1 17 5 05/94 RF0 Bobbin NQI 1.91 18TH TSP

-5.18 F/L 05/94 RF0 Bobbin hol 2.72 18TH TSP

-6.59 F/L 05/94 RF0 C/L Special Int VOL 0.59 19TH TSP

+5.14 18TH TSP 05/94 RF0 C/L Speclat Int VOL 0.62 197H TSP

+3.80 18TH TSP 05/94 RF0 C/L Special Int VOL 1.31 19TH TSP

+2.52 18TH TSP 17 8 05/94 RF0 Bobbin 001 16 1.10 10TH TSP

+4.06 F/L 17 9 05/94 RF0 Bobbin 001 17 0.61 STH TSP

+11.02 F/L 05/94 RF0 Bobbin 001 31 0.44 14TH TSP

+11.13 F/L 17 11 05/94 RF0 Bobbin 001 11 2.03 13TH TSP

+21.61 F/L 05/94 RF0 C/L Special Int VOL 0.83 137H TSP

+21.80 13TH TSP 17 24 05/94 RF0 Bobbin NQI 0.54 11TH TSP

+25.23 F/L 05/94 RF0 C/L Speelat Int VOL 0.92 11TH TSP

+25.17 11TH TSP 17 31 05/94 RF0 Bobbin NQ1 0.29 10TH TSP

+33.*3 F/L 05/94 RF0 Bobbin 001 19 0.40 7TH TSP

+34.35 F/L 05/94 RF0 H/L Special Int vrL 0.60 8TH TSP

-8.63 8TH TSP 05/94 RF0 H/L Special Int.JL 2.60 8TH TSP

-7.63 STH TSP 17 35 05/94 RF0 Bobbin 001 9

1.39 7TH TSP

+21.27 F/L 17 36 05/94 RF0 Bobbin 001 5

0.93 9TH TSP

-1.78 F/L 17 39 05/94 RF0 Bob >in 001 10 0.86 BTH TSP

-1.23 F/L 17 45 05/94 RF0 Bobbin 001 27 0.67 10TH TSP

+17.33 F/L 17 52 05/94 RF0 Bobbin ADI 3.10 9TH TSP

-6.31 F/L 17 61 05/94 RF0 Bobbin 001 17 3.02 14TH TSP

+12.14 F/L 17 63 05/94 RF0 Bobbin 001 24 3.01 3RD TSP

+10.53 F/L 17 80 05/94 RF0 Bobbin 001 39 2.39 13fH TSP

+15.15 F/L 05/94 RF0 C/L Special Int VOL 0.95 13fH TSP

+21.87 13TH TSP 05/94 RF0 C/L Special Int VOL 1.10 13TH TSP

+15.26 13TH TSP 17 85 05/94 RF0 Bobbin NQ1 1.96 19TH TSP

-0.41 F/L 17110 05/94 RF0 Bobbin No!

0.63 STH TSP

+24.72 F/L 05/94 RF0 H/L Special Int VOL 0.95 6TH TSP

-18.73 6TH TSP 18 4 05/94 RF0 Bobbin NQI 0.46 9TH TSP

-8.92 F/L 18 15 05/94 RF0 Bobbin NQI 0.39 11TH TSP

+6.90 F/L 05/94 RF0 Bobbin NQI 0.54 11TH TSP

+12.52 F/L 05/94 RF0 C/L Speciat Int VOL 0.44 11TH TSP

+12.43 11TH TSP 18 17 05/94 RF0 Bobbin 001 35 0.58 10TH TSP

+24.27 F/L 18 36 05/94 RF0 Bobbin ADI 3.17 9TH TSP

-2.54 F/L 05/94 RF0 Bobbin 001 9

1.94 12TH TSP

-12.55 F/L 05/94 RF0 Bobbin 001 19 2.43 13TH TSP

+28.44 F/L 05/94 RF0 C/L Specist Int VOL 0.58 9TH TSP

-3.89 9TH TSP 05/94 RF0 C/L Special Int VOL 3.60 97H TSP

-2.82 9TH TSP 18 37 05/94 RF0 Bobbin NQ1 0.60 14TR ISP

+0.93 F/L 05/94 RF0 C/L Special Int VOL 0.87 15TH (SP

+ 0.49 15fH TSP 05/94 RF0 C/L Special Int VOL 1.31 1 sin TSP

-1.01 15TH TSP 18 38 05/94 RF0 Bobbin 001 19 1.07 10TH TSP

+41.92 F/L 05/94 RF0 C/L Special Int VOL 4.52 97H TSP

-2.83 9TH TSP 18 41 05/94 RF0 Bobbin 001 7

1.50 12TH TSP

+21.72 F/L 18 46 05/94 RF0 Bobbin 001 12 0.69 9TH TSP

-2.74 F/L 18 51 05/94 RF0 Bobbin NQI 0.35 10TH ISP

+41.52 F/L 18 65 05/94 RF0 Bobbin A01 5.71 STH TSP

+24.05 F/L 18 66 05/94 RF0 Bobbin 001 13 1.29 13TH TSP

+18.07 F/L 18 67 05/94 RF0 Bobbin 001 12 3.76 10TH TSP

+4.39 F/L 05/94 RF0 C/L Special Int VOL 0.44 10TH TSP

+3.82 10TH TSP 18 76 05/94 RF0 Bobbin NQI 0.83 9TH TSP

+0.95 F/L 18 84 05/94 RF0 Bobbin ADI 0.80 17TH TSP

-8.98 F/L 18 108 05/94 RF0 Bobbin 001 32 0.69 15TH TCP

-9.48 F/L 18 111 05/94 RF0 Bobbin 001 19 2,38 6TH TSP

+26.26 F/L 05/94 RF0 Bobbin 001 21 2.54 7TH TSP

+15.33 F/L 05/94 RF0 Bobbin 001 24 2.15 2ND TSP

+27.78 F/L 19 16 05/04 RF0 Bobbin ADI 3.76 4TH TSP

+11.38 F/L 05/94 RF0 H/L Special Int VOL 0.77 4TH TSP

+11.15 4TH TSP 19 19 05/94 RF0 Bobbin 001 27 0.66 7TH TSP

+37.89 F/L 19 43 05/94 RF0 Bobbin 001 4

1.45 11TH TSP

+26.82 F/L 19 44 05/94 RF0 Bobbin 001 5

1.16 9TH TSP 7.67 F/L 19 46 05/94 RF0 Bobbin NQI 0.52 10TH TSP

+39.25 F/L 05/94 RF0 Bobbin 001 4

1.10 97H TSP

-3.97 F/L 19 48 05/94 RF0 Bobbin ADI 2.47 1AVB

+ 7. 92 F/L 05/94 RF0 U-Bend VOL 1.43 1AVB

+9.28 1AVB

BWNS TUBAN II (Version 2.0) 06/16/1994 14:17:53 Catawba Nuclear Station - Unit Two S/G A e..........+.***************

05/94 RF0 Bobbin,C/L Special Interest,H/L Special Interest H/L Tubesheet,U-Bend Page 14 of 32

$/G A

  • ATTACHMENT #1 INDICATIONS OF IMPERFECTIONS ROW COL DUTAGE TEST TYPE IND %TW VOLTS LOCATION EXTENT 1 05/94 RF0 Bobbin 00I 1

1.22 BTH TSP 5.93 F/L 19 49 05/94 RF0 Bobbin 001 4

1.09 91H TSP

-4.44 F/L 19 54 05/94 RF0 Bobbin 001 1

1.39 9TH TSP

-3.42 F/L 19 55 05/94 RF0 Bobbin NQ1 0.39 10TH TSP

+37.20 F/L 05/94 RF0 Bobbin 001 3

0.98 10TH TSP

+44.16 F/L 19 56 05/94 RF0 Bobbin 001 14 0.67 10TH TSP

+40.91 F/L 19 57 05/94 RF0 Bobbin ADI 2.64 BTH TSP

-8.39 F/L 05/94 RF0 H/L Speclat Int VOL 0.70 8TH TSP

-8.02 8TH TSP 19 59 05/94 RF0 Bobbin 001 16 0.84 16TH TSP

+0.91 F/L 05/94 RF0 C/L Special Int VOL 1.13 16TH TSP

+0.B4 16TH TSP 19 62 05/94 RF0 Bobbin 001 2

0.59 12TH TSP

+30.54 F/L 19 69 05/94 RFO Bobbin ADI 4.46 6TH TSP

+13.98 F/L 05/94 RF0 H/L Special Int VOL 1.02 6TH TSP

+14.78 6TH TSP 19 94 05/94 RF0 Bobbin ADI 2.82 STH TSP

+10.27 F/L 05/94 RF0 Bobbin NQI 1.30 STH TSP

+12.50 F/L 05/94 RF0 Bobbin 001 12 2.83 4TH TSP

+8.32 F/L 05/94 RF0 Bobbin 001 12 4.83 1ST TSP

+14.81 F/L 05/94 RF0 H/L Special Int VOL 0.63 STH TSP

+9.00 STH TSP 05/94 RF0 H/L Special Int VOL 1.10 STH TSP

+9.66 STH TSP 05/94 RF0 H/L Special Int VOL 1.46 STH TSP

+12.52 STH TSP 19 96 05/94 RF0 Bobbin ADI 7.?8 11TH TSP

+35.22 F/L 05/94 RF0 C/L Special Int VOL 0.35 10TH TSP 8.41 10TH TSP 19 100 05/94 RF0 Bobbin NQI 0.74 IST TSP

+21.33 F/L 05/94 RF0 Bobbin NQI 0.75 2ND TSP

-7.61 F/L 05/94 RF0 H/L Special Int VOL 1.06 2ND TSP

-10.68 2ND TSP 05/94 RF0 H/L Special Int VOL 1.17 2ND TSP

-8.12 2ND TSP 19 103 05/94 RF0 Bobbin No!

0.45 13fH TSP

+24.49 F/L 05/94 RF0 C/L Special Int VOL 0.94 12TH TSP

-18.91 to 13.73 12TH TSP 19 105 05/94 RF0 Bobbin N01 0.72 STH TSP

-1.55 F/L 05/94 RF0 Bobbin 001 13 1.15 91H TSP

-4.44 F/L 05/94 RF0 Bobbin 001 32 1.16 91H TSP

-1.92 F/L 19 107 05/94 RF0 Bobbin ADI 6.41 12TH TSP

+2.89 F/L 05/94 RF0 Bobbin 001 34 1.44 14TH TSP

-1.92 F/L 05/94 RF0 C/L Special Int VOL 0.74 14TH TSP

-2.16 14TH TSP 05/94 RF0 C/L Special Int VOL 1.12 12TH TSP

+2.76 121H TSP 19 110 05/94 RF0 Bobbin ODI 29 0.70 9TH TSP

-4.47 F/L 20 5 05/94 RF0 Bobbin NQI 0.75 10TH TSP

+44.11 F/L 20 12 05/94 RF0 Bobbin 001 15 1.92181H TSP

+8.52 F/L 05/94 RF0 C/L Special Int VOL 0.39 1BTH TSP

+7.76 18TH TSP 20 20 05/94 RF0 Bobbin NQI 0.41 6TH TSP

+24.43 F/L 20 22 05/94 RF0 Bobbin 001 1

1.43 10TH TSP

+44.13 F/L 20 23 05/94 RF0 Bobbin 001 22 0.38 15TH TSP

+8.33 F/L 20 45 05/94 RF0 Bobbin NQI 0.42 9TH TSP

-3.59 F/L 20 46 05/94 RF0 Bobbin NQI 0.39 97H TSP

-5.23 F/L 05/94 RF0 Bobbin 001 13 2.53 7TH TSP

+36.09 F/L 20 52 05/94 RF0 Bobbin 001 9

1.31 91H TSP

-2.81 F/L 20 54 05/94 RF0 Bobbin 001 35 1.12 15TH TSP

+4.37 F/L 05/94 RF0 C/L Special Int VOL 0.53 15TH TSP

+4.05 1STH TSP 20 57 05/94 RF0 Bobbin ADI 1.83 6TH TSP

+20.12 F/L 05/94 RF0 Bobbin 001 32 1.58 6TH TSP

+21.15 F/L 05/94 RF0 Bobbin 001 20 0.78 10TH TSP

+23.12 F/L 05/94 RF0 H/L Special Int VOL 0.46 6TH TSP

+23.72 6TH TSP 05/94 RFO H/L Special Int VOL 0.55 6TH TSP

+21.83 6TH TSP 20 69 05/94 RF0 Bobbin ADI 3.11 181H TSP

+11.47 F/L 05/94 RF0 C/L Special Int VOL 1.03 17TH TSP

-6.83 17TH TSP 20 70 05/94 RF0 Bobbin NQI 0.71 16TH TSP

+5.96 F/L 05/94 RF0 C/L Special Int VOL 0.35 16TH TSP

+2.28 16TH TSP 05/94 RF0 C/L Special Int VOL 0.75 16TH TSP

+ 5. BC 16TH TSP 20 77 05/94 RFC Bobbin 001 18 1.44 4TH TSP

+14.7?

F/L 20 86 05/94'RF0 Bobbin NQ1 0.72 6TH TSP

+9.02 F/L 05/94 RF0 H/L Special Int VOL 0.76 6TH TSP

+8.6?

6TH TSP 20 88 05/94 RF0 Boblin NQ1 0.79 12TH TSP

+!8.26 F/L 05/94 RF0 C/L Special Int VOL 1.11 11TH TSP

-4.88 11TH TSP 20 91 05/94 RF0 Bobbin NOI d.75 5TH TSP

+36.42 F/L 05/94 RF0 H/L Special Int VOL 0.73 6TH TSP

-5.27 6TH TSP 20 92 05/94 RF0 Bobbin NQI 1.83 10TH TSP

+3.74 F/L

BWNS TUBAN 11 (version 2.0) 06/16/1994 14:17:53 Catawba Nuclear Station - Unit Two eeeeee.e. ***...***.....****

S/G A 05/94 RF0 Bobbin,C/L Special Interest H/L Special Interest,H/L Tubesheet,U-Bend Page 15 of 32 S/G A - ATTACHMENT #1 INDICATIONS OF IMPERFECTIONS ROW COL DUTACE TEST TYPE IND %TW VOLTS LOCATION EXTENT 1 05/04 RF0 C/L Special Int VOL 1.08 10TH TSP

+3.85 10TH TSP 20 109 05/94 RF0 Bobbin Nol 1.50 1ST TSP

+21.85 F/L 05/94 RF0 H/L Special Int VOL 1.75 2ND TSP

-6.91 2ND TSP 21 19 05/94 RF0 Bobbin 001 23 0.82 9TH TSP

-13.62 F/L 21 20 05/94 RF0 Bobbin ADI 2.10 10TH TSP

+43.98 F/L 05/94 RF0 Bobbin ADI 2.15 10TH TSP

+43.27 F/L 21 25 05/94 RF0 Bobbin 001 1E 1.30 STH TSP

+9.43 F/L 21 43 05/94 RF0 Bobbin ODI 18 1.10 13TH TSP

+28.08 F/L 21 53 05/94 RF0 Bobbin 001 21 2.31 2ND TSP

+15.83 F/L 21 64 05/94 RF0 Bobbin 001 15 2.53 2ND TSP

+13.04 F/L 21 67 05/94 RF0 Bobbin 001 5

0.98 14TH TSP

+6.95 F/L 21 75 05/94 RF0 Bobbin 001 33 0.38 14TH TSP

+6.79 F/L 21 88 05/94 RF0 Bobbin No!

0.58 7TH TSP

+17.95 F/L 05/94 RF0 M/L Special Int VOL 1.11 TTH TSP

+17.32 7TH TSP 21 89 05/94 RF0 Bobbin NOI 0.86 10TH TSP

+2.44 F/L 05/94 RF0 C/L Special Int VOL 0.34 10TH TSP

+2.23 10TH TSP 21 92 05/94 RF0 Bobbin No!

0.69 7TH TSP

+1.87 F/L 05/94 RF0 Bobbin NOI 0.71 4TH TSP

+2.68 F/L 05/94 RF0 H/L Special Int VOL 0.55 7TH TSP

+ 1. 73 7TH TSP 05/94 RF0 H/L Special Int VOL 0.93 4TH TSP

+2.72 4TH TSP 21 101 05/94 RF0 Bobbin ADI 2.28 7TH TSP

+22.87 F/L 21 102 05/94 kro Bobbin 001 2

0.64 6TH TSP

+28.51 F/L 21 103 05/94 RF0 Bobbin No!

0.73 9TH TSP

-1.93 F/L 05/94 RF0 C/L Special Int VOL 0.91 9TH TSP

-1.66 9TH TSP 05/94 RFC C/L Special Int VOL 1,57 97H TSP

-0.65 9TH TSP 21 106 05/94 RF0 Bobbin NQI 0.77 10TH TSP

+42.82 F/L 05/94 RF0 Bobbin 001 12 0.56 9TH TSP

-5.95 F/L 05/94 RF0 Bobbin DDI 16 0.96 8TH TSP

-7.59 F/L 05/94 RF0 C/L Special Int VOL 0.63 10TH TSP

+39.76 9TH TSP 05/94 RF0 C/L Special Int VOL 1.04 10TH 1SP

+30.97 9TH TSP 05/94 RF0 C/L Special Int VOL 1.04 10TH TSP

+38.22 9TH TSP 05/94 RF0 C/L Special Int VOL 1.49 10TH TSP

+39.31 97H TSP 05/94 RF0 C/L Special Int VOL 2.09 10TH TSP

+32.02 9TH TSP 21 107 05/94 RF0 Bobbin N01 0.97 6TH TSP

-5.09 F/L i

05/94 RF0 H/L Special Int VOL 0.61 6TH TSP 6.13 6TH TSP 05/94 RF0 H/L Special Int VOL 1.44 6TH TSP

-5.17 6TH TSP 22 14 05/94 RF0 Bobbin NQI 0.57 BTH TSP

+ 0. 73 F/L 05/94 RF0 Bobbin 001 12 0.88 BTH TSP

-2.00 F/L 22 20 05/94 RF0 Bobbin 001 20 1.1711TH TSP

+27.38 F/L 22 24 05/94 RF0 Bobbin No!

0.80 12TH TSP

-1.58 F/L 05/94 RF0 Bobbin 001 16 1.20 12TH TSP

+40.96 F/L 05/94 RF0 C/L Special Int VOL 0.77 12TH TSP 2.29 12TH TSP 05/94 RF0 C/L Special Int VOL 0.79 12TH TSP 1.61 12TH TSP 22 27 05/94 RF0 Bobbin 001 27 1,49 17TH TSP

+11.98 F/L 22 41 05/94 RF0 Bobbin No!

0.51 17TH TSP

+2.25 F/L 05/94 RF0 Bobbin 001 8

2.41 2ND TSP

+5.94 F/L 22 44 05/94 RF0 Bobbin 001 16 0.70 10TH TSP

+42.78 F/L 22 74 05/94 RF0 Bobbin 001 25 1.71 11TH TSP

+12.14 F/L 22 76 05/94 RF0 Bobbin 001 22 1.10 131H TSP

+4.59 F/L 22 89 05/94 RF0 Bobbin 001 13 0.98 2ND TSP

+14.38 F/L 05/94 RF0 Bobbin 001 10 1.81 14TH TSP

+11.65 F/L 05/94 RF0 Bobbin 001 19 1.33 14TH TSP

+9.02 F/L 22 96 05/94 RF0 Bobbin ADI 3.66 7TH TSP

+20.75 F/L 05/94 RF0 Bobbin 001 27 0.92 6TH TSP

+19.40 F/L 05/94 RF0 H/L Special Int VOL 1.11 7TH TSP

+20.52 7TH TSP 22 97 05/94 RF0 Bobbin No!

0.57 1ST TSP

+17.71 F/L 05/94 RF0 Bobbin 001 20 1.33 10TH TSP

+13.16 F/L 05/94 RF0 H/L Special Int VOL 0.28 2ND TSP

-10.94 2ND TSP 22 108 05/94 RF0 Bobbin 001 20 0.42 7TH TSP

+39.21 F/L 05/94 RF0 Bobbin 001 33 0.44 10TH TSP

+30.06 F/L 23 16 05/94 RF0 Bobbin ADI 1.89 7TH TSP

+35.99 F/L 23 23 05/94 RF0 Bobbin 001 2

1.71 17TH TSP

+4.46 F/L 05/94 RF0 C/L Special Int VOL 0.5017TH TSP

+4.12 17TH TSP 23 30 05/94 RF0 Bobbin 001 9

1.80 11TH TSP

+19.73 F/L 23 31 05/94 RF0 Bobbin 001 7

0.68 7TH TSP

+8.83 F/L 23 36 05/94 RF0 Bobbin No!

0.45 11TH TSP

+31.50 F/L

BWNS TUBAN 11 (Version 2.0) 06/16/1994 14:17:53 eeeeeeeeeee*****************

Catawba Nuclear Station - Unit Two eeeeeeee.***+...............

Sfg g 05/94 RFO Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U-Bend Page 16 of 32 S/0 A - ATTACHMENT #1 IN01 CATIONS OF IMPERFECTIONS ROW COL DUTAGE TEST TYPE IND %TW VOLTS LOCATION EXTENT 1 05/94 RF0 C/L Special Int VOL 0.78 10TH TSP

-11.51 10TH TSP 23 78 05/94 RF0 Bobbin 001 15 2.07 11TH TSP

+6.12 F/L 23 94 05/94 RF0 Bobbin ADI 2.79 1ST TSP

+23.44 F/L 23 95 05/94 RF0 Bobbin ADI 6.51 6TH TSP

+21.39 F/L 05/94 RF0 H/L Special Int VOL 2.84 6TH TSP

+20.71 6TH TSP 23 104 05/94 RF0 Bobbin 001 12 1.76 10TH TSP

+43.36 F/L 23 106 05/94 RTO Bobbin NQ1 0.70 7TH TSP

+32.45 F/L 23 108 05/94 RF0 Bobbin ADI 3.19 7TH TSP

+25.95 F/L 05/94 RFO Bobbin NQI 0.69 7TH TSP

+34.22 F/L 05/94 RF0 Bobbin 001 27 0.88 7TH TSP

+25.15 F/L 05/94 RF0 Bobbin 001 28 0.36 7TH ISP

+21.75 F/L 05/94 RF0 Bobbin ODI 11 1.07 10TH TSP

+33.14 F/L 24 8 05/94 RF0 Bobbin NQI 0.9710TH TSP

+42.76 F/L 05/94 RF0 C/L Special Int VOL 0.67 9TH TSP

-0.99 9TH TSP 24 15 05/94 RF0 Bobbin 001 8

1.08 18TH TSP

-1.14 F/L 05/94 RF0 Bobbin 001 8

1.50 18TH TSP

+3.17 F/L 05/94 RF0 Bobbin 001 26 1.34 13TH TSP

+12.33 F/L 24 18 05/94 RF0 Bobbin 001 24 1.94 7TH TSP

+33.60 F/L 24 31 05/94 RF0 Bobbin 001 24 0.79 10TH TSP

+38.09 F/L 24 37 05/94 RF0 Bobbin 001 14 3.13 12TH TSP

+4.71 F/L 24 60 05/94 RF0 Bobbin 001 14 0.44 2ND TSP

+25.51 F/L 24 64 05/94 RF0 Bobbin 001 21 1.29 13TH TSP

+14.90 F/L 24 66 05/94 RF0 Bobbin 001 13 0.31 7TH TSP

+36.78 F/L 24 73 05/94 RF0 H/L Tubesheet VOL 0.41 TTS HL

-0.10 TTS-HL 24 77 05/94 RF0 Bobbin ADI 1.53 10TH TSP + 12. 73 F/L 05/94 RF0 C/L Special Int VOL 0.38 10TH TSP

+11.36 10TH TSP 24 79 05/94 RF0 Bobbin NQI 0.35 9TH TSP

-1.52 F/L t

24 82 05/94 RF0 Bobbin ADI 2.77 3AVB

-11.20 V/ '.

i 05/94 RF0 U-Bend VOL 1.06 3AVB 10.55 OTA TSP 05/94 RF0 Bobbin 001 5

0.24 131H TSP

+8.36 r/L 05/94 RF0 Bobbin 001 27 0.30 11TH TSP

+6.05 F/L 24 83 05/94 RF0 Bobbin A01 1.90 19TH TSP

+5.10 F/L 05/94 RF0 C/L Special Int VOL 0.42 19TH TSP

+5.01 18TH TSP 24 84 05/94 RF0 Bobbin 001 3

0.56 77H TSP

+31.21 F/L 05/94 RF0 Bobbin 001 24 2.64 STH TSP

+ 29. 73 F/L 24 89 05/94 RF0 Bobbin A01 2.34 13TH TSP

+32.40 F/L 24 90 05/94 RF0 Bobbin 001 24 1.09 16TH TSP

+ 7. 60 F/L 05/94 RF0 Bobbin 001 34 0.99 11TH TSP

+31.54 F/L 24 93 05/9' RF0 Bobbin 001 22 0.73 12TH TSP

+35.99 F/L 24 94 05, RF0 Bobbin 001 22 2.31 12TH TSP

+38.54 F/L 24 99 05//4 RF0 Bobbin NQI 0.38 10TH TSP

+41.86 F/L 05/94 RF0 C/L Special Int VOL 0.77 10TH TSP

+41.26 9TH TSP 24 100 05/94 RF0 Bobbin 001 14 0.57 10TH TSP

+41.63 F/L 24 103 05/94 RF0 Bobbin 001 18 0.25 10TH TSP

+23.22 F/L 24 106 05/94 RF0 Bobbin 001 10 0.43 12TH TSP

+39.93 F/L 05/94 RF0 C/L Special Int VOL 0.40 12TH TSP

+39.95 11TH TSP 05/94 RF0 C/L Special Int VOL 0.55 12TH TSP

+1.69 11TH TSP 24 108 05/94 RF0 Bobbin NO!

1.26 BTH TSP

-1.42 F/L 05/94 RF0 Bobbin NQ1 1.27 9TH TSP

-3.77 F/L 05/94 RF0 Bobbin 001 12 1.44 71H TSP

+39.37 F/L 05/94 RF0 Bobbin 001 55 0.81 TTH TSP

+29.57 F/L 05/94 RF0 C/L Special Int VOL 0.76 91H TSP

-4.62 9TH TSP 05/94 RF0 C/L Special Int VOL 2.01 9TH TSP

-5.68 9TH TSP i

05/94 RF0 H/L Special Int VOL 0.94 BTH TSP

-12.13 BTH TSP 25 7 05/94 RF0 Bobbin NQI 0.35 6TH TSP

+29.81 F/L 05/94 RF0 Bobbin ADI 2.29 18TH TSP

+5.21 F/L i

05/94 RF0 H/L Special Int VOL 0.56 7TH TSP

-4.88 7TH TSP 05/94 RF0 C/L Special Int VOL 0.16 181H TSP

+4.82 18TH TSP 25 8 05/94 RF0 Bobbin 001 21 1.92 16TH TSP

+13.26 F/L 25 13 05/94 RfD Bobbin NCI 0.5916TH TSP

+11.78 F/L 05/94 RF0 C/L Special Int VOL 0.43 16TH TSP

+12.75 16TH TSP 25 15 05/94 RF0 Bobbin 001 12 0.74 18TH TSP

+2.23 F/L 05/94 RF0 C/L Special Int VOL 0.43 18TH TSP

+2.30 18TH TSP 25 16 05/94 RF0 Bobbin 001 32 0.50 STH TSP

+12.67 F/L 25 19 05/94 RF0 Bobbin 001 20 1.34 6TH TSP

+22.39 F/L 05/94 RF0 Bobbin 001 20 1.67 STH TSP

+11.48 F/L t

BVNS TUBAN II (Version 2.0) 06/16/1994 14:17:53 Catawba Nuclear Station - Unit Two eseeeeeee...................

gfg g 05/94 RF0

    • eeeeee................****

Bobbin,C/L Special Interest,H/L Special Interest,H/L Tv5esheet,U Bend Page 17 of 32 S/G A - ATTACHMENT #1 INDICATIONS OF IMPERFECTIONS ROW COL DUTAGE TEST TYPE IND %TW VOLTS LOCAfl0N EXTENT 1 05/94 RF0 Bobbin DDI 37 0.77 STH TSP

+29.59 F/L 05/94 RF0 H/L Special Int VOL 1.01 6TH TSP

-12.56 6TH TSP 25 23 05/94 RF0 Bobbin 001 27 0.48 7TH TSP

+23.05 F/L 25 24 05/94 RF0 Bobbin ADI 1.60171H TSP

+1.66 to +10.52 F/L 05/94 RF0 C/L Special Int VOL 0.73 17TH TSP

+B.67 16TH TSP 05/94 RF0 C/L Special Int VOL 0.95 17TH TSP

+7.25 16TH T$P 05/94 RF0 C/L Special Int VOL 1.01 17TH TSP

+5.90 16TH TSP 05/94 RF0 C/L Special Int VOL 1.12 17TH TSP

+4.57 16TH TSP 05/94 RF0 C/L Special Int VOL 2.39 171H TSP

+4.87 16TH TSP 25 25 05/94 RF0 Bobbin ADI 5.56 3RD TSP

+24.18 F/L 05/94 RF0 H/L Special Int VOL 0.53 3RD TSP

+27.69 3RD TSP 25 27 05/94 RF0 Bobbin 001 3

0.89 7TH TSP

+12.03 F/L 05/94 RF0 Bobbin 001 32 0.43 7TH TSP

+10.85 F/L 05/94 RF0 H/L SpeciLL Int VOL 0.3J 7TH TSP

+10.30 7TH TSP 05/94 RF0 H/L Special Int VOL 0.60 7TH TSP

+11.42 7TH TSP 25 29 05/94 RF0 Bobbin ADI 7.12 1AVB

+18.65 F/L 25 30 05/94 RF0 Bobbin No!

0.59 10TH TSP

+37.86 F/L 05/94 RF0 Bobbin ODI 2

2.27 14TH ISP

+9.39 F/L 05/94 RF0 Bobbin 001 4

2.7213TH TSP

+10.18 F/L 05/94 RF0 Bobbin 001 9

0.30 10TH TSP

+30.93 F/L 05/94 RF0 C/L Special Int VOL 0.42 14TH TSP

+9.35 14TH TSP 05/94 RF0 C/L Special Int VOL D.45 13TH TSP

+9.45 13TH TSP 25 32 05/94 RF0 Bobbin ODI 2

4.24 6TH TSP

+18.34 F/L 05/94 RF0 Bobbin ODI 2

1.39 12TH TSP

+22.72 F/L 25 37 05/94 RF0 Bobbin 001 2

3.86 3AVB

+1.69 F/L 25 39 05/94 RF0 Bobbin 001 25 1.26 6TH TSP

+15.46 F/L 25 41 05/94 RF0 Bobbin 001 14 5.65 1ST TSP

+27.14 F/L 25 55 05/94 RF0 Bobbin NCI 1.14 12TH TSP

+6.87 F/L 05/94 RF0 C/L Special Int VOL 1.14 12TH TSP

+6.09 12TH TSP 25 62 05/94 RF0 Bobbin DDI 12 0.46 6TH TSP

+38.25 F/L 25 88 05/94 RF0 Bobbin 001 7

2.52 2ND TSP

+17.88 F/L 05/94 RF0 Bobbin DDI 17 2.15 STH TSP

+1.17 F/L 25 101 05/94 RF0 Bobbin ODI 14 0.33 6TH TSP

+34.35 F/L 25 103 05/94 RF0 Bobbin NQ1 0.23 10TH TSP

+37.24 F/L 05/94 RF0 Bobbin 001 10 0.46 10TH TSP

+33.52 F/L 05/94 RF0 Bobbin DDI 11 0.74 10TH TSP

+38.50 F/L 05/94 RF0 C/L Special Int VOL 0.73 10TH TSP

+31.77 97H TSP 05/94 RF0 C/L Special Int VOL 1.6410TH TSP

+32.84 9TH TSP 25 104 05/94 RF0 Bobbin NQI 0.31 7TH TSP

+30.29 F/L 05/94 RF0 Bobbin ADI 2.52 137H TSP

+35.67 F/L 05/94 RF0 C/L Special Int VOL 0.47 12TH TSP

-8.33 12TH TSP 25 106 05/94 RF0 Bobbin 001 18 1.21 10TH TSP

+41.06 F/L 25 107 05/94 RF0 Bobbin 001 6

2.14 STH TSP

+14.17 F/L 25 108 05/94 RF0 Bobbin NQI 0.47 7TH TSP

+31.83 F/L 26 8 05/94 RF0 Bebbin DDI 11 0.64 9TH TSP

-13.30 F/L 05/94 RF0 Bobbin 001 26 0.45 9TH TSP

-12.80 F/L 05/94 RF0 C/L Special Int VOL 0.49 97H TSP

-11.51 9TH TSP 05/94 RF0 C/L Special Int VOL 0.56 9TH TSP

-11.96 9TH TSP 26 11 05/94 RF0 Bobbin 001 2

1.70 2ND TSP

+21.20 F/L 26 14 05/94 RF0 Bobbin DDI 3

0.88 8TH TSP

-2.44 F/L 26 20 05/94 Rr0 Bobbin 001 5

0.49 71H TSP

+ 24. 73 F/L 05/94 RF0 H/L Spectat Int VOL 1.29 BTH TSP

-16.56 BTH TSP 26 24 05/94 RF0 Bobbin No!

0.71 12TH TSP

+6.15 F/L 05/94 RF0 Bobbin DDI 13 0.60 11TH TSP

-1.82 F/L 05/94 RF0 C/L Special Int VOL 0.34 11TH TSP

-1.81 11TH TSP 05/94 RF0 C/L Special Int VOL 0.50 12TH TSP

+6.47 12TH TSP 26 28 05/94 RF0 Bobbin ODI 14 1.28 17TH TSP

+15.03 F/L 05/94 RFC Bobbin 001 17 1.48 16TH TSP

+3.10 F/L 26 30 05/94 RF0 Bobbin DDI 27 0.43 10TH TSP

+39.96 F/L 26 31 05/94 RF0 Bobbin 001 7

1.22 10TH ISP

+33.87 F/L 26 32 05/94 RF0 Bobbin DDI 17 4.57 4AVB

-4.03 F/L 26 39 05/94 RF0 Bobbin DDI B

0.71 7TH TSP

+33.56 F/L 26 71 05/94 RF0 Bobbin NQI 2.15 9TH TSP

-1.49 F/L 05/94 RF0 C/L Special Int VOL 0.96 9TH TSP "1.31 9TH TSP 26 74 05/94 RF0 Bobbin DDI 17 2.06 STH TSP

+30.46 F/L 05/94 RF0 Bobbin ODI 3

1.95 10TH TSP

+1.80 F/L

BWNS TUBAN !! (Version 2.0) 06/16/1994 14:17:53 Catawba Nuclear Station - Unit Two Sfg g 05/94 RF0 Bobbin,C/L special Interest,H/L Special Interest,H/L Tubesheet,U-Bend Page 18 of 32

$/G A - ATTACHMENT #1 INDICATIONS OF IMPERFECTIONS RDW COL DUTAGE TEST TYPE IND %TW VOLTS LOCATION EXTENT 1 05/94 RF0 Bobbin 001 28 1.32 10TH TSP

+23.80 F/L 05/94 RF0 Bobbin 001 33 1.42 10TH TSP

+20.71 F/L 05/94 RF0 C/L Special Int VOL 0.75 10TH TSP

+1.86 10TH TSP 26 77 05/94 RF0 Bobbin NQI 0.57 13TH TSP

-0.31 F/L 05/94 RF0 C/L Special Int VOL 1.15 13TH TSP

-0.10 13TH TSP 26 85 05/94 RF0 Bobbin 001 5

0.68 6TH TSP

+31.15 F/L 26 86 05/94 RF0 Bobbin ADI 4.50 14TH TSP

+13.61 F/L 05/94 RF0 C/L Special Int VOL 0.91 147H TSP

+13.54 14TH TSP 26 88 05/94 RF0 Bobbin Not 0.30 91H TSP

-1.18 F/L 26 90 05/94 RF0 Bobbin 001 22 3.92 14TH TSP

+6.68 F/L 05/94 RF0 C/L Special Int VOL 1.15 14TH TSP

+7.11 14TH ISP 26 95 05/94 RF0 Bobbin 001 21 0.54 10TH TSP

+30.17 F/L 26 96 05/94 RF0 Bobbin ADI 2.46 13fH TSP

+ 7. 61 F/L 05/94 RF0 C/L Special Int VOL 0.21 13fH TSP

+ 7. 48 13TH TSP 26 105 05/94 RF0 Bobbin NOI 0.22 8TH TSP

+ 0. 5 2 F/L 27 13 05/94 RF0 Bobbin NQ1 0.61 17TH TSP

+2.21 F/L 05/94 RF0 Bobbin 001 28 1.69 10TH TSP

+29.04 F/L 05/94 RF0 Bobbin 001 29 1.49 10TH TSP

+28.95 F/L 05/94 RF0 C/L Special Int VOL 0.32 17TH TSP

+2.18 17TH TSP 27 18 05/94 RF0 Bobbin 001 8

1.25 6TH TSP

+10.04 F/L 05/94 RF0 Bobbin 001 9

0.80 7TH TSP

+21.83 F/L 05/94 RF0 Bobbin 001 13 1.28 IST TSP

+2.55 F/L 05/94 RF0 Bobbin 001 28 1.471ST TSP

+23.86 F/L 05/94 RF0 Bobbin 001 17 3.23 13TH TSP

+15.44 F/L 27 19 05/94 RF0 Bobbin No!

0.66 11TH TSP

+B.25 F/L 27 20 05/94 RF0 Bobbin 001 36 0.76 7TH TSP

+21.25 F/L 27 24 05/94 RF0 Bobbin 001 19 1.25 16TH TSP

+14.52 F/L 27 32 05/94 RF0 Bobbin 001 12 0.88 11TH TSP

+23.29 F/L 05/94 RF0 C/L Special Int VOL 0.33 11TH TSF

+22.04 11TH TSP 27 34 05/94 RF0 Bobbin No!

0.41 7TH TSP

+36.28 F/L 05/94 RF0 Bobbin 001 23 0.71 13fH TSP

+36.17 F/L 05/94 RF0 Bobbin 001 30 1.87 10TH TSP

+31.30 F/L 05/94 RF0 H/L Special Int VOL 0.68 8TH TSP

-5.09 BTH TSP 05/94 RF0 H/L Special Int VOL 0.96 BTH TSP

-0.81 BTH TSP 27 43 05/94 RF0 Bobbin 001 16 0.88 7TH TSP

+8.63 F/L 27 48 05/94 RF0 Bobbin 001 30 0.63 10TH TSP

+34.29 F/L 27 49 05/94 RF0 Bobbin 001 20 1.44 7TH TSP

+ 7.15 F/L 27 51 05/94 RF0 Bobbin 001 33 0.49 10TH TSP

+39.58 F/L 27 53 05/94 RF0 Bobbin 001 8

0.95 10TH TSP

+27.71 F/L 27 81 05/94 RF0 Bobbin 001 2

0.61 7TH TSP

+34.28 F/L 27 83 05/94 RF0 Bobbin 001 10 0.40 BTH TSP

+0.64 F/L 27 84 05/94 RF0 Bobbin Not 0.25 15TH TSP

+7.15 F/L 27 85 05/94 RF0 Bobbin 001 38 0.34 16TH TSP

+13.01 F/L 27 87 05/94 RF0 Bobbin 001 37 0.81 STN TSP

+24.86 F/L 05/94 RF0 H/L Special Int VOL 0.87 STH TSP

+25.49 STH TSP 27 92 05/94 RF0 Bobbin ADI 1.90 6TH TSP

+39.69 F/L 05/94 RF0 H/L Special Int VOL 0.56 7TH TSP

-2.73 TTH TSP 27 93 05/94 RF0 Bobbin Nol 0.30 10TH TSP

+38.82 F/L 27 96 05/94 RF0 Bobbin No!

0.32 10TH TSP

+35.09 F/L 05/94 RF0 Bobbin 001 15 0.22 10TH TSP

+37.69 F/L 27 98 05/94 RF0 Bobbin 001 6

0.54 7TH TSP

+38.37 F/L 05/94 RF0 Bobbin 001 18 0.52 TTH TSP

+40.48 F/L 05/94 RFJ Bobbin 001 19 1.52 10TH TSP

+38.47 F/L 27 99 05/94 RF0 Bobbin 001 16 0.5710TH TSP

+36.70 F/L 27 102 05/94 RF0 Bobbin No!

0.35 7TH TSP

+22.64 F/L 05/94 RF0 Bobbin 001 38 2.10 7TH TSP

+28.24 F/L 05/94 RTO Bobbin 001 13 0.5710TH TSP

+41.28 F/L 05/94 RF0 N/L Special Int VOL 1.09 8TH TSP

-19.06 BTH TSP 05/94 RF0 H/L Special Int VOL 1.58 BTH TSP 14.61 BTH TSP 27103 05/94 RF0 Bobbin ADI 3.20 4TH TSP

+24.22 F/L 05/94 RF0 Bobbin 001 33 0.7510TH TSP

+39.78 F/L 27104 05/94 RF0 Bobbin NCI 0.93 13fH TSP

+16.40 F/L 05/94 RF0 Bobbin 001 13 0.81 13fH TSP

+15.10 F/L 05/94 RF0 Bobbin 001 18 1.22 12TH TSP

+24.19 F/L 05/94 RF0 C/L Special Int VOL 0.2713TH TSP

+15.34 13TH TSP 05/94 RF0 C/L Special Int VOL 0.58 13fH TSP

+16. 64 13TH TSP

BWNS TUBAN !] (Version 2.0) 06/16/1994 14:17:53 Catawba Nuclear Station - Unit Two

    • e eeee.*****...***........

gfg A eeeeee....******************

05/94 RF0 Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U-Bend Page 19 of 32 S/G A ATTACHMENT #1 INDICATIONS OF IMPERFECTIONS ROW COL OUTAGE TEST TYPE IND %TW VOLTS LOCAT]DN EXTENT 1 27106 05/94 RfD Bobbin DDI 32 0.89 10TH TSP

+40.99 F/L 28 9 05/94 RF0 Bobbin 001 13 2.04 15TH TSP

+8.21 F/L 05/94 RF0 Bobbin 001 38 0.85 13TH TSP

-12.27 F/L 05/94 RF0 C/L Special Int VOL 0.87 13TH TSP

-11.65 13TH TSP 28 15 05/94 RF0 Bobbin 001 7

1.79 6TH TSP

+33.19 F/L 05/94 RFO Bobbin 001 25 1.72 6TH TSP

+30.31 F/L 28 18 05/94 RF0 Bobbin 001 13 0.57 7TH TSP

+23.27 F/L 28 19 05/94 RF0 Bobbin NQ1 0.65 18TH TSP

+8.06 F/L 05/94 RF0 C/L Special Int VOL 0.58 18TH TSP

+7.27 177H TSP 28 20 05/94 RFO Bobbin NQI 0.64 9TH TSP

+0.52 F/L 28 27 05/94 RF0 Bobbin 001 9

0.89 3RD TSP

+28.05 F/L 05/94 RF0 H/L Special int VOL 1.35 4TH TSP

-7.97 4TH TSP 28 34 05/94 RF0 Bobbin 001 29 0.78 12TH TSP

+13.33 F/L 28 37 05/94 RF0 Bobbin NQI 0.35 97H TSP

-0.66 F/L 05/94 RF0 Bobbin NO!

0.33 10TH TSP

+39.26 F/L 05/94 RF0 Bobbin 001 3

0.41 7TH TSP

+25.41 F/L 05/94 RF0 Bobbin 001 17 0.74 7TH TSP

+18.08 F/L 05/94 RF0 Bobbin 001 38 0.39 7TH TSP

+35.51 F/L 28 39 05/94 RF0 Bobbin 001 8

1.10 7TH TSP

+32.66 F/L 05/94 RF0 Bobbin 001 6

0.44 10TH TSP

+40.91 F/L 28 40 05/94 RF0 Bobbin 001 17 0.78 TTH TSP

+37.00 F/L 28 42 05/94 RF0 Bobbin 001 9

0.92 6TH TSP

+17.75 F/L 05/94 RF0 Bobbin 001 12 0.44 6TH TSP

+9.39 F/L 05/94 RF0 Bobbin 001 30 0.81 10TH TSP

+38.44 F/L 28 45 05/94 RF0 Bobbin NQI 0.86 13TH TSP

+35.04 F/L 05/94 RF0 Bobbin No!

0.93 14TH TSP

+2.49 F/L 05/94 RF0 Bobbin ODI 20 1.11 STH TSP

+25.15 F/L 05/94 RF0 Bobbin 001 35 1.54 STH TSP

+8.22 F/L 05/94 RF0 H/L Special Int VOL 0.56 STH TSP

+27.16 STH TSP 05/94 RF0 H/L Special Int VOL 1.10 STH TSP

+8.79 STH TSP 05/94 RF0 C/L Special Int VOL 0.23 14TH TSP

+3.68 14TH TSP 05/94 RF0 C/L Special Int V0t 0.30 14TH TSP

+9.00 14TH TSP 05/94 RF0 C/L Special Int VOL 0.51 13TF TSP

+34.04 12TH TSP 05/94 RF0 C/L Special Int VOL 0.57 14TH TSP

+2.49 14TH TSP 28 47 05/94 RF0 Bobbfn ADI 1.77 2ND TSP

+10.51 F/L 05/94 RF0 H/L Special Int VOL 0.99 2ND TSP

+11.34 2ND TSP 28 48 05/94 RF0 Bobbin NQI 0.49 1ST TSP

+10.82 F/L 05/94 RF0 Bobbin NQI 0.61 1ST TSP

+1.56 F/L 05/94 RF0 Bobbin NQI 1.49 STM TSP

+6.61 F/L 05/94 RF0 Bobbin N31 0.99 13TH TSP

+36.41 F/L 05/94 RF0 Bobbin NQI 1.17 17TH TSP

+15.13 F/L 05/94 RF0 Bobbin NQI 1.18 13TH TSP

+35.49 F/L 05/94 RF0 Bobbin Nol 115.60 12TH TSP

+38.70 F/L 05/94 RF0 Bobbin 001 13 0.55 TTH TSP

-1.50 F/L 05/94 RF0 Gobbin 001 26 0.65 7TH TSP

+12.74 F/L 05/94 RF0 Bobbin DDI 27 0.54 7TH TSP

+38.92 F/L 05/94 RF0 H/L Special Int VOL 0.57 STH TSP

+6.47 STH TSP 05/94 RF0 H/L Special Int VOL 0.70 1ST TSP

+1.70 1ST TSP 05/94 RF0 H/L Special Int VOL 0.87 STH TSP

+7.29 STH TSP 05/94 RFO H/L Special Int VOL 0.94 1ST TSP

+11.91 1ST TSP 05/94 RF0 C/L Special Int VOL 0.5712TH TSP

-6.55 12TH TSP 05/94 RF0 C/L Special Int VOL 0.58 12TH TSP

-7.50 12TH TSP 05/94 RF0 C/L Special Int VOL 0.61 177H TSP

+14.94 16TH TSP 05/94 RF0 C/L Special Int VOL 0.62 11TH TSP

-4.83 10TH TSP 28 52 05/94 RF0 Bobbin ADI 1.28 12TH TSP

+17.99 F/L 05/94 RF0 C/L Special Int VOL 0.23 12TH TSP

+17.78 12TH TSP 28 53 05/94 RF0 Bobbin DDI 11 0.7218TH TSP

+2.53 F/L 05/94 RF0 Bobbin ODI 20 0.57 18TH TSP

+3.69 F/L 28 56 05/94 RF0 Bebbin DDI 1

2.35 6TH TSP

+37.67 F/L 28 63 05/94 RF0 Bobbin 001 28 1.58 TTS-HL

+6.20 F/L 05/94 RF0 H/L Special Int VOL 0.38 iST TSP

-1.78 1ST TSP 28 68 05/94 RF0 Bobbin No!

0.27 91H TSP

-1.34 F/L 28 74 05/94 RF0 Bobbin ADI 2.98 10TH TSP

+ 7.16 F/L 05/94 RF0 Bobbin ADI 3.01 10TH TSP

+16.53 F/L 05/94 RF0 C/L Special Int VOL 0.56 10TH TSP

+16.16 10TH TSP 05/94 RF0 C/L Special Int VOL 0.79 10TH TSP

+7.16 10TH TSP l

BWNS TUBAN !! (Version 2.0) 06/16/1994 14:17:53 eeeeeeeeeeeeeeeee.**********

Catawba Nuclear Station - Unit Two e eeeeee*****e.......***....

Sfg A 05/94 RF0 Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U-Bend Page 20 of 32

$/G A ATTACHMFNT #1 INDICATIONS OF IMPERFECTIONS ROW COL CF s.ut TEST TYPE IND %TW VOLTS LOCATION EXTENT 1 28 84 05/94 R! J Bobbin 001 13 1.63 11TH TSP

+22.90 F/L 28 88 05/94 RI3 Bobbin No!

0.73 4TH TSP

+19.46 F/L 05/94 R: ' Bobbin 001 1

1.97 13TH TSP

+26.31 F/L 05/94 kFO H/L Special Int VOL 0.63 4TH TSP

< 19.12 4TH TSP 28 96 05/94 RF0 sobbin 001 15 0.71 9TH TSP

-0.68 F/L 05/94 RFC Bobbin DDI 26 1.21 16TH TSP

+9.59 F/L 05/94 RF0 C/L Special Int VOL 2.59 9TH TSP

+0.47 97H TSP 28 99 05/94 RF0 bobbin 001 14 1.55 7TH TSP

+37.89 F/L 05/94 RF0 Bobbin 001 25 1.00 10TH ISP

+33.61 F/L 28 100 05/94 RF0 Bobbin NQI 0.35 7TH TSP

+ 35. 75 F/L 05/94 RF0 Bobbin 001 27 0.75 77H TSP

+39.11 F/L 29 18 05/94 RF0 Bobbin 001 35 0.58 7TH TSP

+20.52 F/L 05/94 RF0 Bobbin 001 19 0.50 10TH TSP

+35.26 F/L 05/94 RF0 H/L Special Int VOL 1.16 77H TSP

+21.10 7TH TSP 29 22 05/94 RF0 Bobbin NQI 1.31 3RD TSP

+ 15. 72 F/L 05/94 RF0 H/L Special Int VOL 0.48 3RD TSP

+28.99 3RD TSP 05/94 RF0 H/L Spectat Int VOL 0.53 3RD TSP

+15.14 3RD TSP 29 24 05/94 RF0 Bobbin hol 0.50 TTH TSP

+33.39 F/L 05/94 RF0 Bobbin 001 32 0.48 7TH TSP

+25.43 F/L 05/94 RF0 H/L Special Int NQI 0.89 BTH TSP

-14.51 to

-3.80 81H TSP 29 25 05/94 RF0 Bobbin 001 10 0.63 10TH TSP

+32.75 F/L 05/94 RF0 Bobbin 001 11 1.52 18TH TSP

+8.56 F/L 29 28 05/94 RF0 Bobbin 001 33 0.30 7TH TSP

+37.24 F/L 05/94 RF0 Bobbin 001 34 0.34 10TH TSP

+43.55 F/L 29 30 05/94 RF0 Bobbin ADI 1.82 71H TSP

+6.77 F/L 05/94 RF0 Bobbin ADI 2.16 13TH TSP

+26.79 F/L 05/94 RF0 Bobbin 001 34 0.81 7TH TSP

+25.71 F/L 05/94 RF0 Bobbin 001 11 0.65 10TH TSP

+37. 75 F/L 05/94 RF0 Bobbin 001 15 1.53 10TH TSP

+39.12 F/L 05/94 RF0 C/L Special Int VOL 0.41 12TH TSP

-15.97 12TH TSP 29 31 05/94 RF0 Bobbin ADI 0.35 10TH TSP

+28.24 F/L 05/94 RF0 Bobbin 001 26 0.81 10TH TSP

+29.39 F/L 05/94 RF0 Bobbin DDI 34 0.22 10TH TSP

+36,25 F/L 29 32 05/94 RF0 Bobbin 001 8

1.01 7TH TSP

+37.36 F/L 05/94 RF0 Bobbin 001 17 0.82 7TH TSP

+38.10 F/L 05/94 RF0 Bobbin 001 8

0.66 1STH TSP

+2.27 F/L 05/94 RF0 Bobbin DDI 11 0.91 10TH TSP

+36.19 F/L 29 36 05/94 RF0 Bobbin ODI 6

0.58 7TH TSP

+36.38 F/L 29 37 05/94 RF0 Bobbin ADI 4.98 8TH TSP

+9.01 F/L 29 39 05/94 RF0 Bobbin 001 20 0.37 7TH TSP

+26.99 F/L 05/94 RF0 Bobbin 001 6

3.35 12TH TSP

+13.69 F/L 05/94 RF0 Bobbin DDI 30 0.42 10TH TSP

+35.78 F, L 29 40 05/94 RF0 Bobbin ADI 0.64 7TH TSP

+36.48 F/L 05/94 RF0 Bobbin NQI 0.49 10TH TSP

+40.62 F/L 05/94 RF0 Bobbin 001 12 1.08 71H TSP

+33.20 F/L 05/94 RF0 Bobbin 001 6

0.51 10TH TSP

+38.10 F/L 05/94 RF0 Bobbin 001 14 1.1710TH TSP

+43.03 F/L 29 44 05/94 RF0 Bobbin 001 3

0.86 10TH TSP

+40.95 F/L 29 48 05/94 RF0 Bobbin 001 4

1.30 7TH TSP

+35.77 F/L 05/94 RF0 Bobbin 001 6

0.88 BTH TSP

-1.38 F/L 05/94 RF0 Bobbin 001 21 0.78 7TH TSP

+38.24 F/L 05/94 RF0 Bobbin 001 39 0.49 7TH TSP

+37.36 F/L 05/94 RF0 Bobbin 001 7

0.73 10TH TSP

+39.54 F/L 29 50 05/94 RF0 Bobbin ADI 4.36 13TH TSP

+10.06 F/L 05/94 RF0 C/L Special Int VOL 0.4713TH TSP

+9.43 13fH TSP 29 51 05/94 RF0 Bobbin NQI 0.50 1CTH TSP

+39.88 F/L 05/94 RF0 Bobbin 001 4

2.25 10TH TSP

+38.05 F/L 05/94 RF0 Bobbin 001 7

2.44 10TH TSP

+41.70 F/L 29 52 05/94 RF0 Bobbin 001 20 1.72 1ST TSP

+14.93 F/L 29 53 05/94 RF0 Bobbin ODI 20 1.23 13TH TSP

+34.60 F/L 29 54 05/94 RF0 Bobbin DDI 15 0.71 10TH TSP

+43.66 F/L 29 61 05/94 RF0 Bobbin ODI 5

0.50 97H TSP 1.83 F/L 05/94 RfD Bobbin 001 19 2.06 14TH TSP

+0.94 F/L 05/94 RF0 C/L Special Int VOL 0.80 9TH TSP

-1.81 97H TSP 05/94 RF0 C/L Special int VOL 0.3714TH TSP

+0.71 14TH TSP 29 78 05/94 RF0 Bobbin 001 29 2.69 STH TSP

+2.37 F/L

BWNS TUBAN !! (Version 2.0) 06/16/1994 14:17:53 eseeeeeee*******************

Catawba Nuclear Station - Unit Two eeeeeeee********************

S/G A 05/94 RF0 Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U Bend Page 21 of 32 S/G A - ATTACHMENT #1 INDICATIONS OF IMPERFECTIONS ROW COL DUTAGE TEST TYPE IND %TW VOLTS LOCATION EXTENT 1 05/94 RF0 H/L Special Int VOL 1.37 STH TSP

+2.84 6TH TSP 29 82 05/94 RF0 Bobbin ADI 4.00 171H TSP

+4.47 F/L 05/94 RF0 C/L Special Int VOL 0.63 17TH TSP

+4.51 17TH TSP 29 92 05/94 RF0 Bobbin ADI 2.11 18TH TSP

+8.08 F/L 05/94 RF0 Bobbin No!

0.29 12TH TSP

+9.43 F/L 05/94 RF0 C/L Special Int VOL 0.41 18TH TSP

+8.05 18TH TSP 29 94 05/94 RF0 Bobbin No!

0.93 13TH TSP

+20.35 F/L 05/94 RF0 C/L Special Int VOL 0.35 9TH TSP

-24.07 97H TSP 29 98 05/94 RF0 Bobbin 001 2

0.72 7TH TSP

+31.42 F/L 29 99 05/94 RF0 Bobbin 001 12 1.04 7TH TSP

+34.68 F/L 29 100 05/94 RF0 Bobbin 001 17 0.68 TTS-CL

+2.99 F/L 05/94 RF0 Bobbin 001 31 2.63 6TH TSP

+6.38 F/L 05/94 RF0 Bobbin 001 19 0.96 14TH TSP

+7.98 F/L 05/94 RF0 Bobbin 001 31 0.95 17TH TSP

+4.42 F/L 05/94 RF0 C/L Special Int VOL 0.38 TTS-CL

+3.81 TTS-HL 29 104 05/94 RF0 Bobbin ADI 2.55 7TH TSP

+9.57 F/L 05/94 RF0 Bobbin 001 3

0.55 77H TSP

+ 29. 72 F/L 05/94 RF0 H/L Special Int VOL 0.59 7TH TSP

+9.86 7TH TSP 30 11 05/94 RF0 Bobbin 001 15 2.05 7TH TSP

+23.45 F/L 30 13 05/94 RF0 Bobbin ADI 2.69 4TH TSP

+6.07 F/L 05/94 RF0 Bobbin No!

0.65 12TH TSP

+10.96 F/L 05/94 RF0 Bobbin 001 20 2.11 11TH TSP

+31.59 F/L 05/94 RF0 H/L Special Int VOL 0.53 4TH TSP

+6.15 4TH TSP 30 15 05/94 RF0 Bobbin DDI 9

0.54 18TH TSP

+12.12 F/L 30 17 05/94 RF0 Bobbin DDI 16 1.05 12TH TSP

+14.29 F/L 30 18 05/94 RF0 Bobbin No!

0.28 10TH TSP

+36.86 F/L 05/94 RF0 Bobbin 001 7

1.64 3RD TSP

+17.70 F/L 05/94 RF0 Bobbin 001 28 0.55 6TH TSP

+10.36 F/L 05/94 RF0 Bobbin 001 39 0.40 3RD TSP

+12.80 F/L 05/94 RF0 Bobbin 001 11 0.33 11TH TSP

+29.16 F/L 05/94 RF0 H/L Special Int VOL 0.99 3RD TSP

+17.64 3RD TSP 30 24 05/94 RF0 Bobbin 001 35 0.37 6TH TSP

+15.59 F/L 30 28 05/94 RF0 Bobbin DDI 17 2.11 16TH TSP

+13.33 F/L 05/94 RF0 C/L Special Int VOL 0.78 15TH TSP

-5.04 15TH TSP 30 29 05/94 RF0 Bobbin NGI 0.35 13TH TSP

+15.25 F/L 05/94 RF0 Bobbin 001 16 0.76 10TH TSP

+38.5 2 F/L 30 31 05/94 RF0 Bobbin ADI 2.24 19TH TSP

+3.79 F/L 05/94 RF0 C/L Special Int VOL 0.37 19TH TSP

+4.69 19TH TSP 05/94 RF0 C/L Special Int VOL 0.64 19TH TSP

+3.50 19TH TSP 30 33 05/94 RF0 Bobbin DDI 17 1.35 1ST TSP

+17.06 F/L 30 34 05/94 RF0 Bobbin No!

0.30 10TH TSP

+27.50 F/L 30 35 05/94 RF0 Bobbin 001 15 0.64 7TH TSP

+39.88 F/L 30 36 05/94 RF0 Bobbin 001 17 1.80 13TH TSP

+32.88 F/L 05/94 RF0 C/L Special Int VOL 0.48 12TH TSP

-10.41 12TH TSP 30 38 05/94 RF0 Bobbin No!

7.12 97H TSP

-1.44 F/L 05/94 RF0 C/L Special Int VOL 0.36 9TH TSP 1.14 9TH TSP 30 40 05/94 RF0 Bobbin 001 1

1.27 77H TSP

+25.20 F/L 05/94 RF0 Bobbin 001 3

1.32 7TH TSP

+25.28 F/L 30 41 05/94 RF0 Bobbin ADI 12.27 2AVB

+8.57 F/L 05/94 RF0 Bobbin 001 3

1.32 2ND TSP

-10.64 F/L 05/94 RF0 U Bend VOL 1.46 2AVB

+9.37 BTH TSP 05/94 RF0 H/L Special Int VOL 0.46 2ND TSP

-10.32 2ND TSP 30 48 05/94 RF0 Bobbin 001 8

0.92 1ST TSP

+14.20 F/L 30 56 05/94 RF0 Bobbin DDI 16 1.00 6TH TSP

+29.22 F/L 05/94 RF0 Bobbin DDI 16 0.4713TH TSP

+28.02 F/L 05/94 RF0 Bobbin 001 16 1.07 13TH TSP

+15.85 F/L 30 61 05/94 RF0 Bobbin 001 25 0.60 12TH TSP

+7.06 F/L j

30 62 05/94 RF0 Bobbin 001 23 0.34 10TH TSP

+35.07 F/L 30 65 05/94 RF0 Bobbin ODI 23 3.17 1STH TSP

+4.58 F/L 30 66 05/94 RF0 Bobbin ADI 2.05 14TH TSP

+14.79 F/L l

05/94 RF0 Bobbin 001 15 2.55 14TH TSP

+8.99 F/L 05/94 RF0 C/L Special Int VOL 0.68 13TH TSP

-3.61 13TH TSP 30 68 05/94 RF0 Bobbin ADI 1.21 1ST TSP

+23.47 F/L l

05/94 RF0 Bobbin 001 17 2.17 11TH TSP

+22.10 F/L 05/94 RF0 H/L Special Int VOL 0.62 2ND TSP

-5.23 2ND TSP 30 80 05/94 RF0 Bobbin 001 4

0.44 13TH TSP

+26.80 F/L l

I

          • e*******.**************

BWNS TUBAN II (Version 2.0) 06/16/1994 14:17:53 Catawba Nuclear Station - Unit Two

$jg 4 05/94 RF0 Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U Bend Page 22 of 32

$/G A - ATTACHMENT #1 INDICATIONS OF IMPERFECTIONS ROW COL OUTACE TEST TYPE IND *atW VOLTS LOCATION EXTENT 1 05/94 RF0 Bobbin 001 31 0.44 11TH TSP

+20.08 F/L 30 83 05/94 RF0 Bobbin ODI 20 0.97 51H TSP

+29.47 F/L 05/94 RF0 Bobbin 001 21 2.50 STH TSP

+33.12 F/L 05/94 RF0 Bobbin 001 23 2.21 STH TSP

+27.70 F/L 30 88 05/94 RF0 Bobbin 001 32 1.61 12TH TSP

+27.36 F/L 30 96 05/94 RF0 Bobbin NOI 0.45 10TH TSP

+10.17 F/L 05/94 RF0 Bobbin ODI 18 3.B8 4TH TSP

+31.92 F/L 05/94 RF0 C/L Special Int VOL 1.79 10TH TSP

+10.89 10TH TSP 30 103 05/94 RF0 Bobbin NQI 1.46 6TH TSP

+28.68 F/L 05/94 RF0 Bobbin 001 22 2.40 3RD TSP

+29.04 F/L 05/94 RF0 Bobbin ODI 24 2.39 3RD TSP

+29.17 F/L 05/94 RF0 Bobbin 001 20 2.71 15TH TSP

+13.03 F/L 31 16 05/94 RF0 Bobbin ADI 4.25 10TH TSP

+17.47 F/L 31 22 05/94 RF0 Bobbin No!

0.40 7TH TSP

+33.16 F/L 05/94 RF0 Bobbin No!

0.55 7TH TSP

+24.21 F/L 31 33 05/94 RF0 Bobbin 001 4

0.56 7TH TSP

+24.37 F/L 05/94 RF0 Bobbin 001 7

0.42 7TH TSP

+23.62 F/L 05/94 RF0 Bobbin 001 27 0.63 71H TSP

+20.36 F/L 31 35 05/94 RF0 Bobbin ADI 8.19 12TH TSP

+39.74 F/L 05/94 RF0 C/L Special Int VOL 0.28 11TH TSP

-6.40 11TH TSP 05/94 RF0 C/L Special Int VOL 0.37 11TH TSP

-4.52 11TH TSP 05/94 RF0 C/L Special Int YOL 0.41 11TH TSP

-3.49 11TH TSP 31 36 05/94 RFO Bobbin DDI 3

0.35 10TH TSP

+20.40 F/L 05/94 RF0 Bobbin 001 4

0.40 10TH TSP

+29.62 F/L 31 38 05/94 RF0 Bobbin ADI 3.08 7TH TSP

+23.51 F/L 31 40 05/94 RF0 Bobbin 001 35 0.46 7TH TSP

+25.90 F/L 31 42 05/94 RF0 Bobbin NQI 1,77 7TH TSP

+28.94 F/L 31 44 05/94 RF0 Bobbin ODI 37 2.52 ISTH TSP

-4.20 F/L 05/94 RF0 C/L Special Int VOL 0.71 15TH TSP

-4.52 15TH TSP 31 48 05/94 RFO Bobbin ADI 2.90 7TH TSP

+15.80 F/L 31 51 05/94 RF0 Bobbin ODI 14 0.71 BTH TSP 1.44 F/L 31 52 05/94 RF0 Bobbin 001 7

0.94 7TH TSP

+15.83 F/L 31 53 05/94 RF0 Bobbin ODI 6

0.85 97H TSP

-2.62 F/L 31 55 05/94 RF0 Bobbin 001 21 0.55 7TH TSP

+33.27 F/L 05/94 RF0 H/L Special Int VOL 0.30 BTH TSP

-19.61 8TH TSP 31 67 05/94 RF0 Bobbin ODI 24 0.29 10TH TSP

+42.31 F/L 31 68 05/94 RF0 Bobbin 001 12 2.74 STH TSP

+20.88 F/L 31 72 05/94 RF0 Bobbin ADI 4.68 STH TSP

+41.56 F/L 05/94 RF0 H/L Special Int VOL 0.76 6TH TSP

-1.69 6TH TSP 31 73 15/94 RF0 Bobbin 001 28 1.64 15TH TSP

+13.06 F/L 31 74 e5/94 RF0 Bobbin ADI 2.39 12TH TSP

+8.32 F/L 31 75 05/94 RF0 Bobbin 001 20 1.22 7TH TSP

+29.63 F/L 05/94 RF0 Bobbin 001 8

1.98 11TH TSP

+14.87 F/L 05/94 RF0 Bobbin ODI 14 1.71 14TH TSP 1,39 F/L 05/94 RF0 C/L Special Int VOL 1.16 14TH TSP

-1.35 14TH TSP 31 80 05/94 RF0 Bobbin ADI 2.48 3RD TSP

+ 15. 64 F/L 31 81 05/94 RF0 Bobbin ADI 5.45 11TH TSP

+27.26 F/L 05/94 RF0 Bobbin 001 16 0.59 7TH TSP

+5.24 F/L 05/94 RF0 C/L Special Int VOL 0.85 11TH TSP

+27.39 11TH TSP 31 82 05/94 RF0 Bobbin ADI 2.76 3RD TSP

+7.94 F/L 05/94 RFO Bobbin ADI 4.59 1ST TSP

+10.00 F/L 05/94 RF0 Bobbin ADI 5.46 3RD TSP

+10.24 F/L 05/94 RF0 Bobbin ODI 3

1.14 7TH TSP

+19.42 F/L 05/94 RF0 H/L Special Int VOL 0.95 1ST TSP

+9.97 151 TSP 05/94 RF0 H/L Special Int VOL 1.61 3RD TSP

+ 10.47 3RD TSP 31 92 03/94 RF0 Bobbin 001 7

1.18 9TH TSP

-0.62 F/L 05/94 RF0 C/L Special Int VOL 3.97 97H TSP

+0.46 91H TSP 31 96 05/94 RF0 Bobbin 001 23 2.57 3AVB

-21.17 F/L 31 99 05/94 RF0 Bobbin 001 14 1.10 10TH TSP

+9.97 F/L i

05/94 RF0 Bobbin 001 17 0.41 10TH TSP

+19.23 F/L 05/94 RF0 Bobbin 001 24 1.m5 13TH TSP

+26.14 F/L 31 103 05/94 RF0 Bobbin WAR 16 0.75 2AVB

+0.00 F/L 31 104 05/94 RF0 Bobbin AD1 1.97 19TH TSP

+3.37 F/L 05/94 RF0 Bobbin ADI 2.33 197H TSP

+1.35 F/L 05/94 RF0 C/L Special Int VOL 0.61 191H TSP

+1.64 19TH TSP 05/94 RF0 C/L Special Int VOL 0.64 19TH TSP

+3.50 19TH TSP I

I 1

BWNS TUBAN 11 (Version 2.0) 06/16/1994 14:17:53 Catawba Nuclear Station - Unit Two

                                      • c********

ee............***...........

gfg 3 05/94 RF0 Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U-Bend Page 23 of 32 S/G A - ATTACHMENT #1 INDICATIONS OF IMPERFECTIONS ROW COL DUTAGE TEST TYPE IND %TW VOLTS LOCATION EXTENT 1 32 13 05/94 RF0 Bobbin 001 17 0.68 15TH TSP

+4.25 F/L 05/94 RF0 C/L Special Int VJL 0.66 15TH TSP

+4.27 15TH TSP 32 34 05/94 RF0 Bobbin 001 3

0.92 11TH TSP

+32.15 F/L 32 38 05/94 RF0 Bobbin 001 12 0.51 6TH 1SP

+23.43 F/L 32 40 05/94 RF0 Bcbbin NO!

0.43 12TH TSP

+26.44 F/L 32 45 05/94 RF0 Bobbin NQI 1.09 3RD TSP

+14.47 F/L 05/94 RF0 H/L Special Int VOL 0.90 3RD TSP

+14.09 3RD TSP 32 48 05/94 RF0 Bobbin ADI B.64 13TH TSP

+33.07 F/L 05/94 RF0 bobbin 001 36 1.40 TfH TSP

+33.90 F/L 05/94 RF0 C/L Special Int VOL 0.8712TH TSP 10.03 12TH TSP 32 70 05/94 RF0 Bobbin No!

0.71 13TH TSP

+17.84 F/L 05/94 RF0 C/L Special Int VOL 0.43 13TH TSP

+18.17 13TH TSP 32 77 05/94 RF0 Bobbin 001 2

2.72 12TH TSP

+35.13 F/L 32 79 05/94 RF0 Bobbin ADI 11.90 7TH TSP

+32.04 F/L 05/94 RF0 Bobbin ODI 11 3.23 12TH TSP

+12.24 F/L 05/94 RF0 Bobbin A01 2.53 17TH TSP

+4.71 to +11.39 F/L 05/94 RF0 C/L Special Int VOL 0.33 17TH TSP

+5.00 to +11.54 17TH TSP 32 80 05/94 RF0 Bobbin 001 1

0.94 7TH TSP

+26.77 F/L 32 8: 05/94 RF0 Bobbin ADI 3.17 12TH TSP

+35.14 F/L 05/94 RF0 C/L Special Int VOL 0.35 11TH TSP 8.71 11TH TSP 32 87 05/94 RF0 Bobbin 001 10 0.65 4TH TSP

+26.49 F/L 32 88 05/94 RF0 Bobbin NQI 0.71 12TH TSP

+33.17 F/L 05/94 RF0 C/L Special Int VOL 0.60 11TH TSP

-10.18 11TH TSP 32 89 05/94 RF0 Bobbin 001 19 2.26 12TH TSP

+9.28 F/L 32 90 05/94 RF0 Bobbin ADI 5.40 4TH TSP

+32.18 F/L 05/94 RF0 H/L Special Int VOL 0.70 STH TSP

-10.30 STH TSP 32 94 05/94 RF0 Bobbin 001 13 0.62 14TH TSP

+7.47 F/L 32 97 05/94 RF0 Bobbin DDI 28 1.13 7TH TSP

+35.61 F/L 32 100 05/94 RF0 Bobbin ODI 10 0.80 12TH TSP

+22.47 F/L 32 103 05/94 RF0 Bobbin 001 9

1.22 7TH TSP

+34.42 F/L 05/94 RF0 Bobbin DDI 7

0.76 10TH TSP

+36.58 F/L 33 12 05/94 RF0 Bobbin ADI 2.91 11TH TSP

+8.25 F/L 05/94 RF0 Bobbin 001 6

2.00 4TH TSP

+35.03 F/L 05/94 RF0 Bobbin ODI 19 1.36 11TH TSP

+6.80 F/L 33 14 05/94 RF0 Bobbin 001 4

4.37 STH TSP

-9.45 F/L 33 15 05/94 RF0 Bobbin NQ1 0.72 2ND TSP

+8.27 F/L 05/94 RF0 H/L Special Int VOL 1.23 2ND TSP

+8.08 2ND TSP 33 17 05/94 RF0 Bobbin C01 24 1.95 15TH TSP

+2.20 F/L 33 22 05/94 RF0 Bobbin ADI 6.59 7TH TSP

+28.21 F/L 05/94 RF0 H/L Special Int VOL 0.83 BTH TSP 10.71 8TH TSP 05/94 RF0 H/L Special Int VOL 0.87 BTH TSP

-14.53 BTH TSP 33 23 05/94 RF0 Bobbin ADI 3.62 10TH TSP

+35.20 F/L 05/94 RF0 Bobbin 001 19 0.61 10TH TSP

+33.74 F/L 05/94 RF0 C/L Special Int VOL 0.93 9TH TSP

-10.47 9TH TSP 05/94 RF0 C/L Special Int VOL 2.47 9TH TSP

-9.47 97H TSP 33 24 05/94 RF0 Bobbin 001 33 1.30 13TH TSP

+41.19 F/L 33 25 05/94 RF0 Bobbin 001 6

0.82 10TH TSP

+36.34 F/L 33 28 05/94 RF0 Bobbin 001 8

0.55 187H TSP

+4.17 F/L 05/94 RF0 Bobbin 001 17 0.68 18TH TSP

+3.18 F/L 33 33 05/94 RF0 Bobbin 001 19 0.63 4TH TSP

+35.66 F/L 33 36 05/94 RF0 Bobbin 001 7

1.01 10TH TSP

+36.46 F/L 05/94 RF0 Bobbin 001 14 1.5817TH TSP

-3.47 F/L 33 40 05/94 RF0 P tbin 001 4

0.52 14TH TSP

+7.31 F/L 33 41 05/94 RF0 bf> bin 001 4

1.75 10TH TSP

+14.49 F/L 05/94 RF0 ;/L Special Int VOL 1.10 10TH TSP

+12.95 10TH TSP 33 42 05/94 RF0 Bobbin ODI 9

1.92 3RD TSP

+ 7. 41 F/L 05/94 RF0 Bobbin ODI 14 3.60 3RD TSP

-2.24 F/L 33 44 05/94 RF0 Bobbin 001 11 1.63 16TH TSP

+5.32 F/L 33 47 05/94 RFO Bobbin DDI 15 1.47 14TH TSP

+9.07 F/L 33 61 05/94 RF0 Bobbin 001 30 0.33 10TH TSP

+33.83 F/L 33 70 05/94 RF0 Bobbin 001 14 0.55 10TH TSP

+26.64 F/L 33 72 05/94 RF0 Bobbin 001 35 1,56 10TH TSP

+11.42 F/L 05/94 RF0 C/L Special Int VOL 0.41 10TH TSP

+10.90 10TH TSP 33 76 05/94 RF0 Bobbin ODI 17 3.88 11TH TSP

+25.68 F/L 33 82 05/94 RF0 Bobbin ODI 20 1.76 3AVB

-6.97 F/L 05/94 RF0 Bobbin 001 6

0.90 15TH TSP

+3.50 F/L

l BWNS TUBAN !! (Version 2.0) 06/16/1994 14:17:53 Catawba Nuclear Station - Unit Two e........................**.

Sfg g eeeeee.*********************

05/94 RF0 Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U-Bend eeee.......................*

Page 24 of 32 S/G A - ATTACHMENT #1 INDICATIONS OF IMPERFECTIONS ROW COL OUTAGE TEST TYPE IND %TW VOLTS LOCATION EXTENT 1 05/94 RF0 Bobbin 001 12 3.06 13TH TSP

+23.57 F/L 33 93 05/94 RF0 Bobbin WAR 15 0.50 2AVB

+0.00 F/L 34 13 05/94 RF0 Bobbin NQI 0.83 18TH TSP

+3.12 F/L 05/94 RF0 C/L Special Int VOL 0.65 18TH TSP

+3.01 18TH TSP 34 14 05/94 RF0 Bobbin 001 13 2.88 7TH ?3P

+20.00 F/L 05/94 RF0 Bobbin 001 31 0.94 7TH TSP

+19.31 F/L 05/94 RF0 Bobbin 001 17 0.68 11TH TSP

+33. 73 F/L 05/94 RF0 Bobbin 001 20 0.58 11TH TSP

+34.42 F/L 34 17 05/94 RF0 Bobbin 001 31 0.86 10TH TSP

+34.49 F/L 05/94 RF0 C/L Special Int VOL 1.18 9TH TSP

-10.12 9TH TSP 34 18 05/94 RF0 Bobbin ADI 7.36 3RD TSP

-2.07 F/L 05/94 RFU H/L Special Int VOL 1.29 3RD TSP 2.65 3RD TSP 4'

34 22 05/94 RF0 Bobbin 001 32 1.33 17TH TSP

+4.58 F/L 34 42 05/94 RF0 Bobbin 001 25 2.99 1ST TSP

+16.31 F/L 34 45 05/94 RF0 Bobbin 001 23 2.28 10TH TSP

+11.81 F/L 34 55 05/94 RF0 Bobbin 001 30 0.72 6TH TSP

+34.74 F/L 05/94 RFC Bobbin 001 8

0.74 10TH TSP

+37.57 F/L 34 61 05/94 RFO Bobbin NQI 0.48 2ND TSP

+10.08 F/L 05/94 RF0 Bobbin 001 22 0.65 2ND TSP

+11.33 F/L j

34 69 05/94 RF0 Bobbin ADI 8.26 2AVB

-0.09 F/L 05/94 RF0 U-Bend VOL 2.89 2AVB

+0.36 3AVB 34 70 05/94 RF0 Bobbin 001 21 0.54 10TH TSP

+37.52 F/L 34 85 05/94 RF0 Bobbin DDI 21 3.7512TH TSP

+4.49 F/L 34 96 05/94 RF0 Bobbin DDI 6

1.95 17TH TSP

+8.52 F/L l

35 14 05/94 RF0 Bobbin WAR 18 0.94 1AVB

+0.00 F/L 05/94 RF0 Bobbin WAR 30 2.28 2AVB

+C.00 F/L 05/94 RFC Bobbin WAR 40 5.56 3AVB

+0.00 F/L 05/94 RF0 U-Bend VOL 1.65 3AVB

+0.00 97H TSP 35 15 05/94 RF0 Bobbin 001 1

0.91 7TH TSP

+23.67 F/L 05/94 RF0 Bobbin 001 8

0.76 7TH TSP

+26.33 F/L 05/94 RF0 Bobbin 001 20 0.38 7TH TSP

+20.17 F/L I

i 35 16 05/94 RF0 Bobbin WAR 20 1.06 2AVB

+0.00 F/L l

l 05/94 RF0 Bobbin 001 11 1.22 7TH TSP

+33.62 F/L i

35 18 05/94 RF0 Bobbin DDI 16 0.54 71H TSP

+28.49 F/L 35 19 05/94 RF0 Bobbin NQI 0.53 9TH TSP

+0.72 F/L 35 21 05/94 RF0 Bobbin DDI 13 1.05 6TH TSP

+27.07 F/L 05/94 RF0 Bobbin ODI 6

1.65 12TH TSP

+19.82 F/L 35 25 05/94 RF0 Bobbin DDI 24 0.44 7TH TSP

+17.22 F/L I

35 26 05/94 RF0 Bobbin ADI 5.58 1ST TSP

+26.73 F/L 05/94 RF0 N/L Special Int VOL 0.66 2ND TSP 1.48 2ND TSP 35 27 05/94 RF0 Bobbin ADI 4.98 3RD TSP

+24.15 F/L 05/94 RF0 H/L Special Int VOL 0.20 3RD TSP

+23.80 3RD TSP 35 28 05/94 RF0 Bobbin WAR 25 1.56 3AVB

+0.00 F/L 35 32 05/94 RF0 Bobbin NQI 1.17 7TH TSP

+19.79 F/L 05/94 RF0 Bobbin NOI 1.86 11TH TSP

+35.18 F/L 05/94 RF0 Bobbin DDI 19 0.95 11TH TSP

+37.37 F/L 05/94 RF0 C/L Special Int VOL 0.51 10TH TSP

-5.58 10TH TSP 05/94 RF0 C/L Special Int VOL 0.94 10TH TSP

-7.76 10TH TSP 05/94 RF0 C/L Special Int VOL 1.14 10TH TSP

-6.87 10TH TSP 35 33 05/94 RF0 Bobbin DDI 4

0.83 TTH TSP

+41.54 F/L 35 42 05/94 RF0 Bobbin 001 27 1.01 9TH TSP

+0.91 F/L 05/94 RF0 C/L Special Int VOL 0.98 91H TSP

+0.96 97H TSP 35 51 05/94 RF0 Bobbin 001 21 1.04 10TH TSP

+14.88 F/L 35 74 05/94 RF0 Bobbin ADI 8.13 BTH TSP

+4.82 F/L 05/94 RF0 Bobbin 001 34 1.99 10TH TSP

+13.62 F/L 05/94 RF0 U-Bend VOL 4.02 BTH TSP

+4.33 BTH TSP 35 100 05/94 RF0 Bobbin ODI 6

0.71 14TH TSP

+13.31 F/L 05/94 RF0 Bobbin 001 7

1.7714TH TSP

+ 7. 26 F/L 05/94 RF0 Bobbin 001 26 1.41 14TH TSP

+6.01 F/L 36 21 05/94 RF0 Bobbin Not 0.60 1biH TSP

+0.90 F/L 05/94 RF0 C/L Special Int VOL 0.21 187H TSP

+0.86 1STH TSP 36 23 J5/94 RF0 Bobbin NQl 1.31 8TH TSP

+11.65 F/L 05/94 RF0 U Bend VOL 0.97 BTH TSP

+10.71 BTH TSP 05/94 RF0 U Bend VOL 1.50 BTH TSP

+12.40 BTH TSP 36 27 05/94 RF0 Bobbin NQI 0.47 11TH TSP

+28.72 F/L 05/94 RF0 Bobbin No!

0.69121H TSP

+30.53 F/L f

._ _ _ ___~

BWNS TUBAN II (Version 2.0) 06/16/1994 14:17:53

  • eeeeeeeeeeeeeeeeeeeeeeee*e.

Catawba Nuclear Station - Unit Two eeeeeee*********************

S/G A 05/94 RF0 Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U-Bend Pa9e 25 of 32 S/G A - ATTACHMENT #1 INDICATIONS OF IMPERFECTIONS RDW COL DUTAGE TEST TYPE IND %TW VOLTS LOCATION EXTENT 1 05/94 RF0 C/L Special Int YOL 0.47 12TH TSP

+30.37 12TH TSP 36 32 05/94 RF0 Bobbin ADI 4.27 177H TSP

+13.86 F/L 05/94 RF0 C/L Special Int VOL 0.38 17TH TSP

+13.62 17TH TSP 36 44 05/94 RF0 Bobbin NQI 0.43 4TH TSP

  • 16.56 F/L 05/94 RF0 H/L Special Int VOL 0.46 4TH TSP

+16.91 4TH TSP 36 52 05/94 RF0 Bobbin 001 4

1.20 11TH TSP

+22.69 F/L 05/94 RF0 C/L Special Int VOL 0.65 11TH TSP

+22.17 11TH TSP 36 68 05/94 RF0 Bobbin No!

0.48 TTH TSP

+15.98 F/L 36 79 05/94 RF0 Bobbin ODI 28 0.65 10TH TSP

+41.61 F/L 05/94 RF0 Bobbin 001 37 0.55 10TH TSP

+38.89 F/L 05/94 RF0 C/L Special Int VOL 0.72 7TH TSP 5.82 9TH TSP 36 90 05/94 RF0 Bobbin 001 31 1.52 12TH TSP

+37.79 F/L 36 91 05/94 RF0 Bobbin 001 20 0.50 10TH TSP

+35.80 F/L 36 98 05/94 RF0 Bobbin No!

0.26 9TH TSP

-0.70 F/L 0?/94 RF0 Bobbin 001 9

0.39 8TH TSP

+0.59 F/L 05/94 RF0 H/L Special Int VOL 0.34 BTH TSP

+1.61 BTH TSP 36 99 05/94 RF0 Bobbin 001 30 0.34 9TH TSP

-1.10 F/L 36 100 05/94 RF0 Bobbin NQI 0.52 7TH TSP

+36.53 F/L 05/94 RTO Bobbin ADI 7.94 12TH TSP

+25.31 F/L 05/94 RF0 Bobbin 001 24 1,46 7TH TSP

+27 67 F/L 05/94 RF0 Bobbin 001 16 0.79 10TH TSP

+41.87 F/L 05/94 RF0 H/L Special Int VOL 1.69 8TH TSP

-5.14 8TH TSP 05/94 RF0 C/L Special Int YOL 0.83 12TH TSP

+25.36 12TH TSP 37 1S 05/94 RFO' Bobbin NQ1 0.54 91H 'SP

+1.59 F/L 37 19 05/94 RF0; Bobbin ADI 6.87 12TH TSP

+18.77 F/L 05/94 RF0 C/L Special Int VOL 0.26 12TH TSP

+17.77 12TH TSP 37 22 05/94 RTO Bobbin DDI 24 1.06 15TH TSP

+11.74 F/L 37 23 05/94 RF0 Bobbin ADI 4.96 2ND TSP

+11.34 F/L 05/94 RF0 Bobbin ADI 3.67 10TH TSP

+30.99 F/L 05/94 RF0 Bobbin NQI 0.99 12TH TSP

+32.03 F/L i

05/94 RF0 Bobbin 001 14 3.97 12TH TSP

+17.91 F/L 05/94 RF0 H/n Special Int VOL 0.95 2ND TSP

+12.06 2ND TSP 05/94 RF0 C/L Special Int VOL 0.64 10TH TSP + 27. 75 10TH TSP 37 il 05/94 RF0 Bobbin DDI 6

2.32 19TH TSP

+6.13 F/L 05/94 RF0 C/L Special Int VOL 0.30 19TH TSP

+6.27 18TH TSP 37 42 05/94 RF0 Bobbin NQ1 0.3514TH TSP

+1.05 F/L 05/94 RF0 Bobbin 001 6

0.53 17TH TSP

+11.85 F/L 05/94 RFO C/L Special Int VOL 0.22 14TH TSP

-1.58 14TH TSP 05/94 RF0 C/L Special Int VOL 0.24 14TH TSP

+1.03 14TH TSP 05/94 RF0 C/L Special Int VOL 0.41 14TH TSP

-0.01 14TH TSP i

37 44 05/94 RF0 Bobbin 001 6 0.7712TH TSP

+33.50 F/L 37 49 05/94 RF0 Bobbin NQI 2.53 4AVB

+11.46 F/L 05/94 RF0 U Bend VOL 2.73 9TH TSP

+18.64 3AVB 37 53 05/94 RFO' Bobbin NQI 1.04 97H TSP

+1.29 F/L 37 54 05/94 RF0 Bobbin NQI 0.37177H TSP

-1.63 F/L 05/94 RF0 Bobbin NQI 0.76 17TH TSP

-1.06 F/L 05/94 RF0 Bobbin ADI 6.77 17TH TSP

+1.17 to

+8.06 F/L

+

05/94 RF0 C/L Special Int VOL 0.8017TH TSP 0.42 17TH TSP 05/94 RF0 C/L Special Int VOL 0.72 177H TSP

+0.74 to

+8.15 17TH TSP 37 56 05/94 RF0 Bobbir.

NQI 0.59 Sf H TSP

+26.79 F/L 05/94 RF0 H/L ipe:ial Ir.t VOL -

1.57 $TH TSP

+26.34 STH TSP 37 62 05/94 RF0 Bobbin ADI 1.82 6TH TSP

+25.99 F/L 05/94 RFO H/L Special Int VOL 0.60 7TH TSP

-15.46 7TH TSP 05/94 RF0 H/L Special Int YOL 0.84 7TH TSP

-16.27 7TH ISP 37 65 05/94 RF0 Bobbin NQI 2.82 1ST TSP

+24.60 F/L 05/94 RF0 H/L Rpecial Int VOL 1.05 2ND TSP

-3.12 2ND TSP 37 66 05/94 RF0 Bobbin NQI 0.68 7TH TSP

+41.27 F/L 37 70 05/94 RF0 Bobbin NQI 0.36 10TH TSP

+38.53 F/L 05/94 RF0 hobbin 001 12 0.53 2ND TSP

+19.37 F/L 05/94 RF0 C/L Special Int VOL 0.48 9TH TSP

+6.02 97H TSP 37 71 05/94 RFC lobbin NQI 0.80 2ND TSP

+13.50 F/L 05/94 RF0 Sebbin No!

0.45 177H TSP

+14.68 F/L 05/94 RF0 Hit Special Int VOL 1.68 2ND TSP

+13.68 2ND TSP 05/94 RF0 C/L Special Int VOL 0.51 16TH TSP

-3.49 16TH TSP 37 90 05/94 RF0 Bcbbin NQ1 0.52 10TH TSP

+40.01 F/L 05/94 RF0 C/L Special Int VOL 0.30 9TH TSP

-4.72 9TH TSP i

i

BWNS TUBAN II (Version 2.0) 06/16/1994 14:17:53 e***************************

Catawba Nuclear Station Unit Two e e ee ee.....................

gfg g 05/94 RF0 Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U-Bend

    • eeeeee.........***********

Page 26 of 32 S/G A - ATTACHMENT #1 INDICATIONS OF IMPERFECTIONS RDW COL OUTAGE TEST TYPE IND %TW VOLTS LOCATION EXTENT 1 1

37 93 05/94 RF0 Bobbin ODI 32 0.46 10TH TSP

+15.18 F/L 37 99 05/94 RF0 Bobbin 001 5

1.31 7TH TSP

+30.60 F/L 38 17 05/94 RF0 Bobbin WAR 19 2.15 3AVB

+0.00 F/L 05/94 RF0 U-Bend VOL 1.02 3AVB

+0.00 1AVB 38 18 05/94 RF0 Bobbin 001 30 1.58 7TH TSP

+39.31 F/L 38 19 05/94 RF0 Bobbin No!

0.29 7TH TSP

+27.67 F/L 38 20 05/94 RF0 Bobbin DDI 11 0.86 7TH TSP

+34.28 F/L 38 31 05/94 RF0 Bobbin 001 7

0.90 7TH TSP

+20.80 F/L 76 35 05/94 RF0 Bobbin ADI 5.5717TH TSP

+11.67 F/L 05/94 RF0 C/L S >ecial Int VOL 1.09 16TH TSP

-6.78 16TH TSP 38 36 05/94 RF0 Bobbin ADI 7.39 14TH TSP

+12.62 F/L 05/94 RF0 Bobbin ODI 25 1.67 17TH TSP

+13.87 F/L 05/94 RF0 C/L Special Int VOL 0.45 13TH TSP

+4.94 13TH TSP 05/94 RF0 C/L Speclat Int VOL 0.82 13fH TSP

-5.53 13fH TSP i

38 44 05/94 RF0 Bobbin ADI 6.13 4TH TSP

+30.19 F/L j'

05/94 RF0 H/L Special Int VOL 0.90 STH TSP

-12.15 STH TSP 05/94 RF0 Bobbin NQI 1.57 2ND TSP

+19.95 F/L 05/94 RF0 H/L Special Int VOL 1.76 3RD TSP

-15.15 3RD TSP 38 46 05/94 RF0 Bobbin NQI 0.50 18TH TSP

+1.12 F/L 38 53 05/94 RF0 Bobbin NQI 0.87 lith TSP

+24.78 F/L 05/94 RF0 C/L Special Int VOL 0.45 11TH TSP

+23.96 11TH TSP 38 55 05/94 RF0 Bobbin NQI 0.53 6TH TSP

+34.45 F/L 05/94 RF0 H/L Speclat Int VOL 1.69 7TH TSP

-7.02 7TH TSP 38 61 05/94 RF0 Bobbin NQI 0.49 STH TSP

+1.48 F/L 38 64 05/94 RF0 Bobbin NQI 0.55 STH TSP

+27.63 F/L 3

05/94 RF0 N/L Special Int VOL 0.81 6TH TSP 15.36 6TH TSP 38 68 05/94 RF0 Bobbin 001 4

0.81 4TH TSP

+3.77 F/L 38 70 05/94 RF0 Bobbin NQI 0.51 7TH TSP

+19.46 F/L 38 83 05/94 RF0 Bobbin ODI 6

0.56 7TH TSP

+33.52 F/L 05/94 RF0 Bobbin 001 13 0.65 7TH TSP

+32.56 F/L i

38 84 05/94 RF0 Bobbin NQI 0.29 9TH TSP

-0.99 F/L 05/94 RF0 C/L Special Int VOL 0.69 9TH TSP

-0.78 9TH TSP 38 96 05/94 RF0 Bobbin WAR 25 1.46 2AVB

+0.00 F/L 38 97 05/94 RF0 Bobbin WAP 18 0.83 4AVB

+0.00 F/L 05/94 RF0 Bobbin WAR 22 1.15 3AVB

+0.00 F/L 05/94 R50 Bobbin WAR 34 2.63 2AVB

+0.00 F/L 05/94 RTO Bobbin NQI 0.33 6TH TSP

+14.38 F/L 38 98 05/94 RF0 Bobbin WAR 15 0.68 3AVB

+0.00 F/L 39 26 05/94 RF0 Bobbin 001 7

0.66 10TH TSP

+28.45 F/L 39 31 05/94 RF0 Bobbin WQI 1.26 97H TSP

+1.21 F/L 05/94 RF0 U-Bend VOL 0.53 9TH TSP

+1.36 4AVB

]

39 32 05/94 RF0 Bobbin NQI 0.51 13TH TSP

+26.44 F/L i

05/94 RF0 C/L Special Int VOL 0.48 13TH TSP

+25.92 12TH TSP 39 33 05/94 RF0 Bobbin NQI 0.36 9TH TSP

+0.71 F/L 05/94 RF0 C/L Special Int VOL 0.36 9TH TSP

+0.71 9TH TSP 39 37 05/94 RF0 Bobbin NQI 0.38 6TH TSP

+24.45 F/L 05/94 RF0 N/L Special Int VOL 0.48 6TH TSP

+24.13 7TH TSP 39 46 05/94 RF0 Bobbin NQI 0.36 10TH TSP

+24.63 F/L 05/94 RF0 Bobbin NQ!

0.69 13TH TSP

+11.49 F/L 05/94 RF0 Bobbin WQt 0.93 10TH TSP

+23.31 F/L 05/94 RF0 Bobbin NQI 1.26 10TH TSP

+21.96 F/L 4

05/94 RF0 C/L Soecial Int VOL 0.59 10TH TSP

+20.87 10TH TSP 05/94 RF0 C/L Soecist Int VOL 0.59 10TH TSP

+21.50 10Th TSP 05/94 RF0 C/L Speclat Int VOL 0.73 10TH TSP

+20.23 10TH TSP 39 49 05/94 RF0 Bobbin No!

D.43 7TH TSP

+22.43 F/L 39 51 05/94 RF0 Bobbin DDI 10 0.60 10TH TSP

+12.78 F/L 39 54 05/94 RF0 Bobbin NQ!

0.52 10TH TSP

+5.40 F/L 05/94 RF0 Bobbin ODI 17 0.82 11TH TSP

+36.14 F/L 39 60 05/94 RF0 Bobbin NQI 0.56 10TH TSP

+36.17 F/L 05/94 RF0 C/L Special Int VOL 0.74 9TH TSP

-8.50 9TH TSP 39 66 05/94 RF0 Bobbin NQt 0.83 BTH TSP

+1.58 F/L 05/94 RF0 U-Bend VOL 0.49 BTH TSP

+1.33 BTH TSP 39 68 05/94 RF0 Bobbin NQ1 0.47 10TH TSP

+7.20 to +10.13 F/L 05/94 RFO C/L Special Int VOL 0.3010TH TSP

+9.03 10TH TSP 39 91 05/94 RF0 Bobbin ADI 0.83 10TH TSP

+20.73 F/L 05/94 RF0 C/L Special Int VOL 0.38 10TH TSP

+17.82 10TH TSP

BWNS TUBAN 11 (Version 2.0) 06/16/1994 14:17:53 Catawba Nuclear Station - Unit Two Sfg 4 05/94 RF0 Bobbin,C/L Special Interest,H/L Speciat Interest,H/L Tubesheet,U Bend Page 27 of 32 S/G A - ATTACHMENT #1 INDICATIONS OF IMPERFECTIONS ROW COL DUTAGE TEST TYPE IND %TW VOLTS LOCATION EXTENT 1 05/94 *F0 C/L Special Int VOL 0.93 10TH TSP

+19.45 10TH TSP 39 93 05/94 RF0 Bobbin 001 10 1.05 10TH TSP

+43.30 F/L 05/94 RF0 C/L Special Int VOL 0.51 97H TSP

-1.50 9TH TSP 40 18 05/94 RF0 Bobbin WAR 30 2.47 3AVB

+0.00 F/L 40 19 05/94 RF0 Bobbin NQI 0.22 7TH TSP

+29.40 F/L 05/94 RF0 Bobbin No!

0.47 7TH TSP

+28.86 F/L 05/94 RF0 Bobbin NQI 0.58 71H TSP

+25.62 F/L 05/94 RF0 Bobbin NCI 2.75 7TH TSP

+24.59 F/L 05/94 RF0 Bobbin ADI 0.67 10TH TSP

+21.52 F/L 05/94 RF0 Bobbin NQI 0.72 10TH TSP

+29.11 F/L 05/94 RF0 Bobbin 001 37 2.05 7TH TSP

+23.85 F/L 05/94 RF0 Bobbin 001 16 0.65 10TH TSP

+41.41 F/L 05/94 RF0 H/L Special Int VOL 0.56 7TH TSP

+24.08 BTH TSP 05/94 RF0 C/L Special Int VOL 1.71 10TH TSP

+20.14 9TH TSP 40 22 05/94 RF0 Bobbin 00!

17 1.12 14TH TSP

+3.47 F/L 40 26 05/94 RF0 Bobbin NQI 0.32 7TH TSP

+25.55 F/L 05/94 RF0 Bobbin NCI 0.33 7TH TSP

+23.47 F/L 05/94 RF0 Bobbin NCI 0.56 7TH TSP

+23.69 F/L 40 27 05/94 RF0 Bobbin ADI 12.78 STH TSP

+21.82 F/L 05/94 RF0 Bobbin 001 12 1.78 6TH TSP

+18.52 F/L 05/94 RF0 H/L Special Int VOL 0.23 STH TSP

+23.04 STH TSP 05/94 RF0 H/L Special Int VOL 0.43 STH TSP

+22.09 STH TSP 40 28 05/94 RF0 Bobbin A01 3.86 12TH TSP

+16.26 F/L 05/94 RF0 C/L Special Int VOL 0.72 12TH TSP

+15.74 12TH TSP 40 31 05/94 RF0 Bobbin 001 27 0.62 7TH TSP

+2.83 F/L 40 44 05/94 RF0 Bobbin ADI 4.55 14TH TSP

+12.50 F/L 05/94 RF0 Bobbin NQI 0.72 16TH TSP

+1.95 F/L 05/94 RF0 Bobbin NQI 0.91 10TH TSP

+40.17 F/L 05/94 RF0 C/L Special Int VOL 0.58 16TH TSP

+2.05 16TH TSP 05/94 RF0 C/L Special Int VOL 0.73 14TH TSP

+12.07 14TH TSP i

40 50 05/94 RF0 Bobbin 001 24 1.59 17TH TSP

+7.03 F/L 05/94 RF0 C/L Special Int VOL 0.50 17TH TSP

+7.03 17TH TSP 40 52 05/94 RF0 Bobbin 001 33 0.87 2ND TSP

+26.26 F/L 40 54 05/94 RF0 Babbin NO!

3.64 3AVB

+2.57 F/L 05/94 RF0 Bobbin 001 7

4.69 3AVB

+14.41 F/L 05/94 RF0 U-Bend VOL 0.54 3AVB

+2.78 1AVB 05/94 RF0 Bobbin 001 12 2.55 10TH TSP

+5.41 F/L 05/94 RF0 Bobbin 001 15 3.16 10TH TSP

+17.70 F/L 40 60 05/94 RF0 Bobbin 001 7

0.55 7TH TSP

+32.42 F/L 05/94 RF0 Bobbin 001 24 0.24 7TH TSP

+32.28 F/L 05/94 RF0 H/L Special Int VOL 1.11 8TH TSP

-10.33 BTH TSP 40 61 05/94 RF0 Bobbin ADI 2.33 12TH TSP

+2.52 F/L 05/94 RF0 C/L Special Int VOL 0.44 12TH TSP

+3.67 12TH TSP 05/94 RF0 C/L Special Int VOL 0.53 12TH TSP

+2.30 12TH TSP 40 64 05/94 RF0 Bobbin ODI 7

0.81 2ND TSP

+33.31 F/L 40 68 05/94 RF0 Bobbin 001 4

0.62 BTH TSP

-0.72 F/L 40 72 05/94 RF0 H/L Tubesheet WQI 19.18 TTS HL

+0.00 TTS-HL 40 86 05/94 RF0 Bobbin ADI 2.70 16TH TSP

+ 7. 03 F/L 05/94 RF0 C/L Special Int VOL 0.60 16TH TSP

+6.76 16TH TSP 40 87 05/94 RF0 Bobbin ADI 3.55 16TH TSP

+4.04 F/L 05/94 RFO C/L Special Int YOL 0.53 16TH TSP

+4.51 16TH TSP 40 91 05/94 RF0 Bobbin 001 14 1.32 6TH TSP

+8.18 F/L 40 94 05/94 RF0 Bobbin WAR 26 1.56 2AVB

+0.00 F/L 40 95 05/94 RF0 Bobbin WAR 20 0.97 4AVB

+0.00 F/L 05/94 RF0 Bobbin WAR 25 1.45 2AVB

+0.00 F/L 41 22 05/94 RF0 Bobbin 001 28 1.04 7TH TSP

+25.38 F/L 41 27 05/94 RF0 Bobbin 001 12 0.88 10TH TSP

+32.65 F/L 41 31 05/94 RF0 Bobbin 001 25 0.44 7TH TSP

+19.97 F/L 41 45 05/94 RF0 Bobbin 001 15 1.55 12TH TSP

+1.43 F/L 05/94 RF0 C/L Special Int VOL 0.76 12TH TSP

+1.49 12TH TSP 41 56 05/94 RF0 Bobbin NQI 0.52 BTH TSP

+0.71 F/L 41 63 05/94 RF0 Bobbin 001 27 0.39 6TH TSP

+15.38 F/L 41 81 05/94 RF0 Bobbin WAR 14 0.61 3AVB

+0.00 F/L 05/94 RF0 Bobbin WAR 22 1.14 2AVB

+0.00 F/L 41 82 05/94 RF0 Bobbin NCI 0.61 12TH TSP

+10.38 F/L 05/94 RF0 C/L Special Int VOL 0.90 12TH TSP

+10.88 12TH TSP

BWNS TUBAN II (Version 2.0) 06/16/1994 14:17:53 Catawba Nuclear Station - Unit Two

  • ee******..............*****

S/G A

  • e*********......***********

05/94 RF0 Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubssheet,U-Bend

  • e***ee**..*****************

Page 23 of 32 S/G A - ATTACHMENT #1 INDICATIONS OF IMPERFECTIONS RDW COL OUTAGE TEST TTPE IND %TW VOLTS LOCATION EXTENT 1 41 84 05/94 RF0 Bobbin NCI 0.32 STH TSP

-0.52 F/L 05/94 RF0 Bobbin NQ1 1.90 BTH TSP

+0.64 F/L 41 85 05/94 RF0 Bobbin WAR 17 0.81 3AVB

+0.00 F/L 41 90 05/94 RF0 Bobbin WAR 13 0.54 3AVB

+0.00 F/L 41 92 05/94 RF0 Bobbin WAR 10 0.43 4AVB

+0.00 F/L 05/94 RF0 Bobbin WAR 16 0.71 3AVB

+0.00 F/L 41 94 05/94 RF0 Bobbin WAR 20 1.01 2AVB

+0.00 F/L 05/94 RF0 Bobbin WAR 31 2.06 3AVB

+0.00 F/L 42 21 05/94 RF0 Bobbin ODI 16 2.39 13TH TSP

+20.37 F/L 42 22 05/94 RF0 Bobbin ADI 1.56 10TH TSP

+36.01 F/L 05/94 RF0 Bobbin 001 13 0.61 12TH TSP

+12.43 F/L 05/94 RF0 C/L Special Int VOL 0.48 12TH TSP

+12.43 12TH TSP 42 27 05/94 RF0 Bobbin ODI 29 0.54 7TH TSP

+17.43 F/L 42 30 05/94 RF0 Bobbin DDI 17 0.70 7TH TSP

+15.98 F/L 42 45 05/94 RF0 Bobbin ADI 8.13 77H TSP

+33.06 F/L 05/94 RF0 Bobbin ODI 21 0.90 16TH TSP

+5.34 F/L 42 53 05/94 RF0 Bobbin ADI 9.49 4TH TSP

+25.43 F/L 05/94 RF0 H/L Special Int VOL 1.59 4TH TSP

+25.54 4TH TSP 42 54 05/94 RF0 Bobbin ADI 8.06 17TH TSP

+5.01 F/L 05/94 RF0 Bobbin ADI 13.68 15fH TSP

+7.88 F/L 05/94 RF0 C/L Special Int VOL 0.61 17TH TSP

+ 4. 64 17TH TSP 05/94 RF0 C/L Special Int VOL 1.16 1STH TSP

+7.56 15TH TSP 42 66 05/94 RF0 Bobbin ADI 4.62 1ST TSP

+0.78 to

+7.21 F/L 42 70 05/94 RF0 Bobbin ODI 15 1.01 11TH TSP

+21.57 F/L 42 75 05/94 RF0 Bobbin DDI 29 1.48 12TH TSP

+13.70 F/L 42 76 05/94 RF0 Bobbin DDI 10 1.48 9TH TSP

-12.34 F/L 42 81 05/94 RF0 Bobbin WAR 13 0.70 2AVB

+0.00 F/L 42 85 05/94 RF0 Bobbin WAR 29 2.37 2AVB

+0.00 F/L 42 91 05/94 RF0 Bobbin WAR 14 0.76 3AVB

+0.00 F/L 42 92 05/94 RF0 Bobbin 001 27 0.36 7TH TSP

+23.21 F/L

^

43 26 05/94 RF0 Bobbin ADI 6.59 2ND TSP

+22.18 F/L 05/94 RF0 H/L Special Int VOL 0.83 3RD TSP

-8.81 3RD TSP 05/94 RF0 H/L Special Int VOL 0.92 3RD TSP

-3.93 3RD TSP 05/94 RF0 H/L Special Int VOL 1.39 3RD TSP

-13.28 3RD TSP 43 29 05/94 RF0 Bobbin 001 15 0.90 BTH TSP

-0.55 F/L 43 31 05/94 RF0 Bobbin No!

0.47 6TH TSP

+18.11 F/L 43 39 05/94 RF0 Bobbin No!

0.65 2ND TSP

+16.63 F/L 05/94 RF0 H/L Special Int VOL 1.32 2ND TSP

+15.91 2ND TSP 43 49 05/94 RF0 Bobbin DDI 4

2.47 11TH TSP

+24.58 F/L 05/94 RF0 C/L Special Int VOL 0.93 11TH TSP

+23.97 11TH TSP 43 50 05/94 RF0 Bobbin 001 19 1.12 STH TSP

+22.40 F/L 43 55 05/94 RF0 Bobbin ADI 5.61 3AVB

-6.58 F/L 05/94 RF0 Bobbin ADI 6.85 3AVB

+1.43 F/L 05/94 RF0 Bobbin NQI 0.88 3AVB

-17.72 F/L 05/94 RF0 Bobbin 001 29 2.07 3AVB

-14.81 F/L 05/94 RF0 U-Bend VOL 0.56 2AVB

+13.14 1AVB 05/94 RF0 U-Bend VOL 0.62 3AVB

+1.05 1AVB 05/94 RF0 U Bend VOL 0.65 2AVB

+5.49 1AVB 05/94 RF0 U-Bend VOL 0.74 3AVB

-6.55 1AVB 05/94 RF0 U-Bend VOL 0.85 3AVB

-17.57 1AVB 05/94 RF0 U-Bend VOL 0.92 3AVB

-14.67 1AVB 05/94 RF0 Bobbin 001 10 1.09 14TH TSP

+15.67 F/L 05/94 RF0 Bobbin 001 14 0.69 13TH TSP

+3.41 F/L C5/94 RF0 C/L Special Int VOL 0.21 13TH TSP

+3.08 13fH TSP l

05/94 RF0 C/L Special Int VOL 0.3014TH TSP

+12.58 13TH TSP i

43 56 05/94 RFC C/L Special Int VOL 1.81 18TH TSP

+0.79 18TH TSP I

43 62 05/94 RF0 Bobbin 001 4

0.63 10TH TSP

+43.49 F/L 05/94 RF0 C/L Special Int VOL 1.29 9TH TSP

-1.33 9TH TSP 43 64 05/94 RF0 H/L Tubesheet YOL 1.09 TTS-HL

-1.16 TTS-HL 43 91 05/94 RF0 Bobbin WAR 12 0.64 2AVB

+0.00 F/L 05/94 RF0 Bobbin WAR 12 0.66 3AVB

+0.00 F/L 05/94 RF0 Bobbin WAR 18 1.07 4AVB

+0.00 F/L 43 93 05/94 RFO Bobbin ADI 6.48 11TH TSP

+11.07 F/L 05/94 RF0 C/L Special Int VOL 0.55 11TH TSP

+11.20 11TH TSP 44 23 05/94 RF0 Bobbin WAR 22 1.34 4AVB

+0.00 F/L 05/94 RF0 Bobbin WAR 23 1.43 2AVB

+0.00 F/L

    • .eeeeeeeeeeeeeee***eneeee.

BWNS TUBAN 11 (Version 2.0) 06/16/1994 14:17:53

                    • eeseeee***********

Catawba Nuclear Station - Unit Two Sfg A 05/94 RF0 Bobbin,C/L Special Interest,H/L Special Inters-t.H/L Tubesheet,U-Bend Page 29 of 32 S/G A - ATTACHMENT #1 INDICATIONS OF IMPERFECTIONS ROW COL DUTAGE TEST TYPE IND %TW VOLTS LOCATION EXTENT 1 05/94 RF0 Bobbin WAR 39 4.76 3AVB

+0.00 F/L 05/94 RF0 U-Bend VOL 1.46 3AVB

+0.00 3AVB 05/94 RF0 Bobbin ADI 21.08 BTH TSP

+23.73 F/L 05/94 RFO U Bend VOL 1.59 BTH TSP

+22.73 8TH TSP 44 28 05/94 RF0 Bobbin 001 5

3.64 13TH TSP

+4.26 F/L 44 31 05/94 RF0 Bobbin NQI 0.59 7TH TSP

+18.88 F/L 44 40 05/94 RF0 Bobbin 001 9

2.87 14TH TSP

+3.23 F/L 05/94 RF0 Bobbin 001 10 3.13 18TH TSP

+12.70 F/L 05/94 RF0 Bobbin DDI 18 5.81 17TH TSP

+8.58 F/L 05/94 RF0 Bobbin DDI 24 2.18 17TH TSP

+8.02 F/L 44 41 05/94 RF0 Bobbin ADI 4.09 12TH TSP

+6.93 F/L 05/94 RF0 C/L Special Int VOL 0.86 12TH TSP

+5.83 12TH TSP 44 42 05/?4 RF0 Bobbin NQI 0.3710TH TSP

+18.35 F/L 05/94 RFC C/L Special. Int VOL 0.26 10TH TSP

+16.58 10TH TSP 44 43 05/94 RF0 Bobbin No!

0.29 6TH TSP

+18.81 F/L 44 46 05/94 RF0 Bobbin NQI 0.48 11TH TSP

+25.67 F/l 05/94 RF0 Bobbin 001 26 2.91 STH TSP

+12.58 F/L 05/94 RF0 C/L Special Int VOL 0.60 11TH TSP

+25.01 11TH TSP 44 47 05/94 RF0 Bobbin ADI 8.86 13TH TSP

+ 8. 74 F/L 05/94 RF0 Bobbin DDI 20 6.91 2ND TSP

+15.54 F/L 05/94 RF0 Bobbin 001 5

2.91 13TH TSP

+20.85 F/L 05/94 RF0 C/L Special Int VOL 0.85 13TH TSP

+19.98 13TH TSP 05/94 RF0 C/L Special Int VOL 1.01 13TH TSP

+8.02 13TH TSP 05/94 RF0 C/L Special Int VOL 1.11 13TH TSP

+1.41 13TH TSP 44 49 05/94 RF0 Robbin Wal 0.39 7TH TSP

+37.95 F/L 05/94 RF0 Bobbin NQI 0.51 7TH TSP

+30.65 F/L 05/94 RF0 Bobbin 001 30 0.50 6TH TSP

+18.21 F/L 05/94 RF0 Bobbin 001 38 0.55 7TH TSP

+27.02 F/L 05/94 RF0 Bobbin 001 20 0.57 10TH TSP

+28.23 F/L 05/94 RF0 Bobbin DDI 24 0.94 10TH TSP

+28,73 F/L 44 51 05/94 RF0 Bobbin NQI 0.44 7TH TSP

+21.51 F/L 05/94 RF0 H/L Special Int VOL 2.52 7TH TSP

+24.26 7TH TSP 44 60 05/94 RF0 Bobbin DDI 15 0.76 7TH TSP

+28.94 F/L 44 61 05/94 RF0 Bobbin NQI 1.67 11TH TSP

+2.36 F/L 05/94 RF0 C/L Special Int VOL 1.23 11TH TSP

+2.55 11TH TSP 44 62 05/94 RF0 Bobbin NQI 0.29 10TH TSP

+43.23 F/L 05/94 RF0 Bobbin 001 34 0.60 7TH TSP

+35.95 F/L 05/94 RF0 C/L Special Ir-VOL 1.23 9TH TSP

-1.57 9TH TSP 44 63 05/94 RF0 Bobbin 001 22 1.96 7TH TSP

-3.92 F/L 44 66 05/94 RF0 Bobbin ADI 18.72 3AVB

+18.25 F/L 05/94 RF0 Bobbin NQI 1.35 4AVB

-31.31 F/L 05/94 RF0 Bobbin ADI 4.22 STH TSP

+34.35 F/L 05/94 RF0 Bobbin NQI 0.64 STH TSP

-1.17 F/L

[

05/94 RF0 U Bend VOL 2.53 3AVB

+17.10 9TH TSP 44 79 05/94 RF0 Bobbin 001 26 1.41 77H TSP

-2.76 F/L 44 81 05/94 RF0 Bobbin ADI 1.55 10TH TSP

+23.16 F/L 05/94 RF0 C/L Special Int VOL 0.61 10TH TSP

+21.69 10TH TSP 44 82 05/94 RF0 Bobbin ODI 12 0.98 87H TSP

-1.46 F/L 05/94 RF0 H/L Special Int VOL 0.37 BTH TSP

-1.47 BTH TSP i

44 89 05/94 RF0 H/L Tubesheet VOL 0.88 TTS-HL

+3.94 TTS-HL 45 26 05/94 RF0 Bobbin WAR 22 1.26 3AVB

+0.00 F/L 45 30 05/94 RF0 Bobbin ADI 2.64 7TH TSP

+27.58 F/L 05/94 RF0 Bobbin ADI 5.00 BTH TSP

+25.95 F/L 05/94 RF0 Bobbin NQI 0.28 77H TSP

+26.61 F/L 05/94 RF0 Bobbin NQI 0.48 TTH TSP

+26.80 F/L 45 34 05/94 RF0 Bobbin ADI 8.50 3RD TSP

+11.63 F/L 05/94 RF0 Bobbin ADI 2.9815TH TSP

+26.11 F/L 45 36 05/94 RF0 Bobbin ADI 0.65 13TH TSP

+7.68 F/L 45 41 05/94 RF0 Bobbin No!

0.45 15TH TSP

+26.09 F/L 05/94 RF0 C/L Special Int VOL 0.21 15TH TSP

+26.09 15TH TSP 45 42 05/94 RF0 Bobbin NQi 0.76 STH TSP

+35.08 F/L 05/94 RF0 H/L Special Int VOL 0.87 6TH TSP

-8.78 6TH TSP 45 43 05/94 RFO Bobbin NQI 1.07 4AVB

-32.44 F/L 45 68 05/94 RF0 Bobbin NQ1 0.42 6TH TSP

+18.48 F/L 45 76 05/94 RF0 Bobbin DDI 30 1.3311TH TSP

-6.11 F/L 45 81 05/94 RF0 Bobbin ADI 5.21 7TH TSP

+22.58 F/L

BWNS TUBAN 11 (Version 2.0) 06/16/1994 14:17:53 Catawba Nuclear Station - Unit Two S/G A e.**************************

05/94 RF0 Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U Bend i

Page 30 of 32 S/G A - ATTACHMEWT #1 INDICATIONS OF IMPERFECTIONS RDW COL DUTAuC TEST TYPE IND %TW VOLTS LOCATION EXTENT 1 05/94 RF0 H/L Special Int VOL 1.87 7TH TSP

+23.12 77H TSP 45 B4 05/94 RF0 cobtin No!

0.39 11TH TSP

+24.23 F/L 05/94 RF0 Bobbin 001 19 0.81 6TH TSP

+34.54 F/L 05/94 RF0 Bobbin DDI 12 0.81 10TH TSP

+22.78 F/L 05/94 RF0 Bobbin 001 15 0.4711TH TSP

+28.21 F/L 05/94 RF0 Bobbin 001 16 0.2710TH TSP

+2.96 F/L 05/94 RF0 C/L Special Int VOL 0.82 11TH TSP

+26.49 11TH TSP 05/94 RF0 C/L Special Int VOL 1.03 11TH TSP

+25.36 11TH TSP 45 88 05/94 RF0 Bobbin NQI 0.50 18TH TSP

-1.61 F/L 05/94 RF0 C/L Special Int VOL 0.25 18TH TSP

-1.50 18TH TSP 45 90 05/94 RF0 Bobbin WAR 16 0.90 3AVB

+0.00 F/L 45 91 05/94 RF0 Bobbin WAR 22 1.41 4AVB

+0.00 F/L 46 26 05/94 RF0 Bobbin 001 9

2.13 2ND TSP

+17.65 F/L 46 30 05/94 RF0 Sobbin ADI 5.79 3AVB 29.69 F/L l

05/94 RF0 U-Bend VOL 0.46 4AVB

-0.92 3AVB I

05/94 RF0 Bobbin ADI 6.56 17TH TSP

+29.50 F/L 05/94 RF0 Bobbin No!

1.59 18TH TSP

+12.87 F/L 05/94 RF0 Bobbin 001 22 5.17 6TH TSP

+15.94 F/L 05/94 RF0 Bobbin 00!

5 1.39 17TH TSP

+14.76 F/L 05/94 RF0 C/L Special Int VOL 0.57 1BTH TSP

+12.87 18TH TSP 05/94 RF0 C/L Special Int VOL 0.64 17TH TSP

+28.09 17TH TSP 46 31 05/94 RF0 Bobbin Nul 0.83 81H ISP

-0.49 F/L 05/94 RF0 H/L Special Int VOL 0.72 BTH TSP

+0.44 BTH TSP 46 32 05/94 RF0 Bobbin ADI 6.66 TTS-HL

+5.98 F/L 05/94 RF0 Bobbin ADI 3.59 STH TSP

+12.16 F/L 05/94 RF0 Bobbin ADI 4.69 6TH TSP

+33.30 F/L 05/94 RF0 Bobbin ADI 1.94 12TH TSP

+32.52 F/L 05/94 RF0 H/L Special Int VOL 0.61 TTS-HL

+5.37 1ST TSP 05/94 RF0 H/L Special Int VOL 0.61 7TH TSP

-9.38 71H TSP

[

05/94 RF0 H/L Special Int VOL 0.90 STH TSP

+12.28 STH TSP 2

05/94 RF0 C/L Special Int VOL 0.74 12TH TSP

+32.52 12TH TSP i

46 74 05/94 RF0 Bobbin ADI 1.64 7TH TSP

+25.95 F/6 46 3) 05/94 RF0 Bobbin NQI 2.33 12TH TSP

+9.68 F/L 05/94 RF0 Bobbin 001 2

3.60 3RD TSP

+8.05 F/L 05/94 RF0 C/L Special Irt VOL 1.22 12TH TSP

+9.45 12TH TSP 46 40 05/94 RF0 Bobbin No!

1.11 3RD TSP

+25.95 F/L 05/94 RF0 Bobbin NQI 1.22 2ND TSP

+32.62 F/L 05/94 RF0 H/L Special Int VOL 0.80 3RD TSP

+24.79 3RD TSP 05/94 RF0 H/L Special Int VOL 0.82 3RD TSP

+31.44 3RD TSP 46 45 05/94 RF0 Bobbin 001 15 1.49 11TH TSP

+27.16 F/L' 05/94 RF0 C/L Special Int VOL 0.80 11TH TSP

+26.23 11TH TSP 46 53 05/94 RF0 Bobbin 001 21 0.68 177H TSP

+12.76 F/L 46 81 05/94 RF0 Bobbin 001 16 1.87 3AVB

-19.58 F/L 05/94 RF0 Bobbin 001 13 2.59 18TH TSP

+7.33 F/L 05/94 RF0 C/L Special Int VOL 0.45 18TH TSP

+7.96 15TH TSP 46 87 05/94 RF0 Bobbin ADI 5.11 7TH TSP

+12.03 F/L 05/94 RF0 H/L Special Int VOL 1.15 7TH TSP

+12.03 7TH TSP 46 89 05/94 RF0 Bobbin NQ1 0.49 97H TSP

-1.48 F/L 47 27 05/94 RF0 Bobbin WAR 23 1.53 3AVB

+0.00 F/L 05/94 RF0 Bobbin ADI 10.27 12TH TSP

+21.60 F/L 47 28 05/94 RF0 Bobbin NOI 1.78 4AVB

+26.05 F/L 05/94 RF0 Bobbin 001 14 1.07 4AVB

-21.73 F/L 05/94 CFO U-Bend VOL 1.50 4AVB 29.50 2AVB 05/94 RF0 Bobbin NQI 1.03 11TH TSP

+26.02 F/L 05/94 R50 C/L Special Int VOL 0.o6 11TH TSP

+26.50 11TH TSP 47 33 05/94 RF0 Bobbin ADI 3.10 15TH TSP

+22.41 F/L 05/94 RF0 Bobbin ADI 3.23 17TH TSP

+27.65 F/L 05/94 RF0 Bobbin ADI 3.25 15fH TSP

+23.36 F/L 05/94 RF0 Bobbin ADI 5.98 177H TSP

+29.24 F/L 05/94 RF0 Bobbin NQ1 0.89 18TH TSP

+7.66 F/L 05/94 RF0 C/L Special Int VOL 0.36 15TH TSP

+23.60 15fH TSP 05/94 RF0 C/L Special Int VOL 0.44 15TH TSP

+22.41 15TH TSP 05/94 RF0 C/L Special Int VOL 0.5917TH TSP

+27.65 17TH TSP 05/94 RF0 C/L Special Int VOL 0.80 171H TSP

+29.24 17TH TSP 05/94 RF0 C/L Special Int VOL 1.26 18TH TSP

+7.66 18TH TSP i

47 34 05/94 RF0 Bobbin Nol 0.4617TH TSP

+2.81 F/L

+

BWNS TUBAN !! (Version 2.0) 06/16/1994 14:17:53 e***************************

Catawba Nuclear Station - Unit Two eeeeeeeeee....eeeeeees.eeese

  • o********.e***************

gjg A eeeeeeeeeeessesessese***esee 05,94 pro seessesseeeeeeeeeeeeeeeessee Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U-Bend PaDe 31 of 32 S/G A - ATTACHMENT #1 INDICATIONS OF IMPERFECTIONS ROW COL DUTAGE TEST TYPE IND %TW VOLTS LOCATION EXTENT 1 05/94 RF0 C/L Special Int VOL 0.33 17TH TSP

+2.81 171H TSP 47 35 05/94 RF0 Bobbin ADI 1.42 11TH TSP

+16.29 F/L 05/94 RF0 Bobbin ADI 3.35 13TH TSP

-1.55 F/L 65/94 RFO C/L Special Int VOL 0.60 13TH TSP

-1.55 13TH TSP 05/94 RFO C/L Special. Int VOL 1.29 111H TSP

+15.45 11TH TSP 47 36 05/94 RF0 Bobbin ADI 2.21 17TH TSP

+4.33 F/L 05/94 RF0 C/L Special Int VOL 0.67 17TH TSP

+4.33 17TH TSP 47 38 05/94 RF0 Bobbin ADI 1.28 17TH TSP

+26.51 F/L 05/94 RF0 Bobbin NQI 0.47 17TH TSP

+27.86 F/L 05/94 RF0 C/L Special Int VOL 0.3617TH TSP

+26.51 17TH TSP 05/94 RF0 C/L Special Int YOL 0.4717TH TSP

+27.86 17TH TSP 47 43 05/94 RF0 Bobbin NOI 2.18 1AVB

+18.69 F/L 05/94 RF0 Bobbin 001 25 2.68 3AVB

+12.95 F/L 05/94 RF0 U-Bend VOL 4.05 1AVB

+17.88 1AVB 47 46 05/94 RF0 Bobbin 001 19 1.78 11TH TSP

+8.36 F/L 47 55 05/94 RF0 Bobbin ADI 5.44 4TH TSP

+20.00 F/L 05/94 RTO Bobbin ADI 3.73 10TH TSP

+19.60 F/L 05/94 RF0 C/L Special Int VOL 0.37 10TH TSP

+19.60 10TH TSP 05/94 RF0 C/L Special Int VOL 0.61 10TH TSP

+8.64 10TH TSP 47 56 05/94 RF0 Bobbir WAR 18 1.31 2AVB

+0.00 F/L 05/94 RF0 Bobbir WAR 22 1.78 4AVB

+0.00 F/L 05/94 RF0 Bobbir WAR 35 4.89 3AVB

+0.00 F/L 05/94 RF0 U-Bend VOL 0.99 3AVB

+0.00 2AVB 47 59 05/94 RF0 C/L Special Int VOL 1.00 177H TSP

-2.03 17TH TSP 47 62 05/94 RFO Bobbin ADI 6.21 3AVB

-3,08 F/L 05/94 RFO Bobbin ADI 7.14 19TH TSP

-1.85 F/L 05/94 RF0 C/L Spectat Int VOL 0.50 191H TSP 3.06 191H TSP 47 65 05/94 RF0 Bobbin ADI 6.59 10TH TSP

+6.86 F/L 05/94 RF0 C/L Special Int VOL 0.54 10TH TSP

+6.27 10TH TSP 47 67 05/94 RF0 Bobbin ADI 3.67 BTH TSP

+22.87 F/L 47 75 05/94 RF0 Bobbin DDI 17 5.84 1ST TSP

-2.26 F/L 05/94 RF0 H/L Special Int VOL 1.09 1ST TSP

-1.91 1ST TSP 47 77 05/94 RFO Bobbin ODI 21 1.09 10TH TSP

+40.10 F/L 47 84 05/94 RF0 Bobbin 001 3

1.44 6TH TSP

+34.00 F/L 48 29 05/94 RF0 Bobbin NQI 0.56 17TH TSP

+17.05 F/L 05/94 RF0 Bobbin NOI 1.19 12TH TSP

+26.12 F/L 05/94 RF0 C/L Special Int VOL 1.52 12TH TSP

+26.12 12TH TSP 48 32 05/94 RF0 Bobbin 001 20 0.91 TTH TSP

+23.76 F/L 48 33 05/94 RF0 Bobbin NQI 0.51 8TH TSP

+2.78 F/L 48 35 05/94 RF0 Bobbin ADI 3.64 7TH TSP

+35.05 F/L 05/94 RF0 Bobbin ADI 5.70 STH TSP

+19,77 F/L 05/94 RF0 Bobbin 001 10 0.97 7TH TSP

+25.60 F/L 05/94 RF0 H/L Special Int VOL.

0.26 8TH TSP

-6.74 BTH TSP 05/94 RF0 H/L Special Int YOL 0.41 STH TSP

+20.98 STH TSP

]

05/94 RF0 H/L Special Int VOL 1.12 STH TSP

+19.65 STH TSP 48 39 05/94 RF0 Bobbin WQI 1.83 10TH TSP

+21.63 F/L 05/94 RF0 C/L Special Int VOL 1.39 10TH TSP

+21.63 10TH TSP 05/94 RF0 C/L Special Int VOL 1.73 10TH TSP

+20.92 10TH TSP 48 46 05/94 RF0 Bobbin NQI 0.42 7TH TSP

+20.58 F/L 05/94 RF0 Bobbin NOI 0.51 13TH TSP

+32.35 F/L 05/94 RF0 C/L Special Int VOL 0.96 12TH TSP

-9.47 12TH TSP 48 50 05/94 RF0 Bobbin ADI 3.53 7TH TSP

+31.96 F/L 48 ^52 05/94 RF0 Bobbin ADI 10.01 17TH TSP

+4.26 F/L 05/94 RF0 C/L Special Int VOL 0.4917TH TSP

+4.26 17TH TSP 48 53 05/94 RF0 Bobbin 001 10 0.71 7TH TSP

+40.04 F/L 48 56 05/94 RF0 Bobbin 001 35 0.72 1AVB

+ 7.12 F/L 48 68 05/94 RF0 Bobbin ADI 5.56 10TH TSP

+43.38 F/L 05/94 RF0 C/L Special Int VOL 0.70 9TH TSP

-2.58 9TH TSP 48 73 05/94 RF0 Bobbin No!

0.34 13TH TSP

+6.06 F/L 05/94 RF0 C/L Special Int VOL 0.45 13TH TSP

+6.06 13TH TSP 48 75 05/94 RF0 Bobbin DDI 20 1.44 10TH TSP

+41.09 F/L 48 76 05/94 RF0 Bobbin ODI 24 0.36 10TH TSP

+41.96 F/L 48 80 05/94 RF0 Bobbin 001 15 0.75 TTH TSP

+20.62 F/L 48 84 05/94 RF0 Bobbin DDI 29 1.29 10TH TSP

+23.12 F/L 48 85 05/94 RF0 Bobbin 001 25 0.88 10TH TSP

+43.29 F/L 49 31 05/94 RFO Bobbin ADI 7.35 11TH TSP

-1.55 F/L i

i

BWNS TUBAN II (Version 2.0) 06/16/1994 14:17:53 Catewba Nuclear Station - Unit Two eeeeeeee..******************

S/G A 05/94 RF0 Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U-Bend Page 32 of 32 S/G A - ATTACHMENT #1 INDICATIONS OF IMPERFECTIONS RDW COL DUTAGE TEST TYPE IND %TW VOLTS LOCA110N EXTENT 1 05/94 RFO C/L Special Int VOL 1.70 111H TSP

-1.55 11TH TSP 49 43 05/94 RFO Bobbin ADI 3.99 15TH TSP

+13.64 F/L 05/94 RFO Bobbin ADI 4.14 1STH TSP

+16.07 F/L 05/94 RF0 Bobbin NQI 0.41 10TH TSP

+15.04 F/L 05/94 RF0 C/L Special Int VOL 0.54 15TH TSP

+13.64 15fH TSP 05/94 RF0 C/L Special Int VOL 0.82 15TH TSP

+16.07 15TH TSP 49 45 05/94 RF0 Bebbin No!

1.10 15TH TSP

+13.17 F/L 05/94 RF0 C/L Special Int VOL 0.77 1STH Tre

+13.17 ISTH TSP 49 47 05/94 RF0 Bobbin No!

0.58 10TH TSP

+22.59 F/L 05/94 RF0 Bobbin NQI 3.56 10TH TSP

+20.39 F/L 05/94 RF0 C/L Special Int VOL 0.47 10TH TSP

+17.12 10TH TSP 05/94 RF0 C/L Special Int VOL 1.45 10TH TSP

+18.15 10TH TSP 49 53 05/94 RF0 Bobbin NQI 0.47 1STH TSP

+14.33 F/L 05/94 RF0 Bobbin DDI 16 1.25 151H TSP

+18.75 F/L 49 62 05/94 RF0 Bobbin NQ1 0.66 1ST TSP

+22.48 F/L l

05/94 RF0 Bobbin NQI 0.73 1ST TSP

+21.18 F/L l

05/94 RF0 Bobbin No!

0.90 1ST TSP

+20.52 F/L 49 67 05/94 RF0 Bobbin NO!

2.22 8TH TSP

+2.99 F/L 05/94 RF0 C/L Special Int VOL 0.20 18TH TSP

+0.00 18TH TSP 49 70 05/94 RF0 Bobbin ADI 3.45 3RD TSP

+ 17. 64 F/L 05/94 RF0 H/L Special Int VOL 0.56 3RD TSP

+19.95 3RD TSP l

49 73 05/94 RF0 C/L Special Int VOL 1.50 18TH TSP

+0.00 18TH TSP j

49 75 05/94 RF0 Bobbin No!

0.42 BTH TSP

-0.55 F/L

{

49 80 05/94 RF0 dobbin 001 15 1.63 18TH TSP

+1.72 F/L 05/94 RF0 C/L Special Int VOL 0.44 181H TSP

+0.00 18TH TSP Total Indications Found = 2071 Total Tubes Found = 913 i

l

)

1 3

I 5

)

i ATTACIIMENT 2 P

l I

I I

l 1

I I

v

l BWNS TUBAN !! (Version 2.0) 06/17/1994 06:22:10 eeeeeeeeeeeee***************

Catawba Nuclear Station - Unit Two eeeeeeee***.. ****..........

gfg g 05/94 RF0 e......................*****

Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U-Bend Page 1 of 21 S/C B - ATTACHMENT #2 INDICATIONS OF IMPERFECTIONS ROW COL DUTAGE TEST TYPE IND %TW VOLTS LOCATION EXTENT 1 1

6 05/94 RF0 Bobbin 001 17 2.5616TH TSP

+17.42 BTH TSP 05/94 RF0 C/L Special Int VOL 2.00 16TH TSP

+14.38 16TH TSP 05/94 RF0 C/L Special Int VOL 3.41 16TH TSP

+17.4 2 lolH TSP 1 14 05/94 RF0 Bobbin ADI 7.74 6TH TSP

+3.05 8TH TSP 05/94 RF0 H/L Special Int VOL 1.37 6TH TSP

+6.24 6TH TSP 1 40 05/94 RF0 Bobbin 001 4

0.73 4TH TSP

+7.18 STH TSP 1 49 05/94 RF0 N/L Tubesheet VOL 0.45 TTS-ML

+0.69 TTS-HL 1 51 05/94 RF0 Bobbin 001 12 0.72 TTS-ML

+2.58 BTH TSP 1 52 05/94 RF0 Bobbin 001 12 1.62 2ND TSP

+4.99 BTH TSP 1 56 05/94 RF0 Bobbin NQI 1.66 4TH TSP

+38.B4 8TH TSP 05/94 RF0 H/L Special Int VOL 1.17 STH TSP

-4.40 STH TSP 1 62 05/94 RF0 Bobbin 001 8

2.75 13f H TSP

+40.17 8TH TSP 05/94 RF0 C/L Special Int VOL 1.2712TH TSP

-3.30 12TH TSP 1 63 05/94 RF0 Bobbin 001 17 0.71 4TH TSP

+8.12 BTH TSP 1 73 05/94 RF0 Bobbin ADI 3.29 BTH TSP

+6.96 8TH TSP 1 82 05/94 RF0 Bobbin No!

0.38 10TH TSP

+29.95 BTH TSP 1 84 05/94 RF0 Bobbin 001 17 2.59 12TH TSP

+12.33 8TH TSP 1 88 05/94 RF0 Bobbin 001 8

0.87 BTH TSP

+4.42 8TH TSP 1 90 05/94 RF0 Bobbin ADI 1.00 3RD TSP

+14.41 BTH TSP 05/94 RF0 H/L Special Int VOL 0.46 3RD TSP

+14.28 3RD TSP 1 91 05/94 RF0 Bobbin ADI 1.58 7TH TSP

+8.38 BTH TSP 05/94 RF0 H/L Special Int VOL 2.17 7TH TSP

+8.44 7TH TSP 2 3 05/94 RF0 Bobbin 001 1

1.09 IST TSP

+21.87 BTH TSP 05/94 RF0 Bobbin 001 12 1.801ST TSP

+12.22 8TH TSP 2 4 05/94 RF0 Bobbin NCI 0.65 4TH TSP

+19.34 BTH TSP 05/94 RF0 H/L Special Int VOL 0.65 4TH TSP

+20.13 4TH TSP 2 9 05/94 RF0 Bobbin No!

0.68 12TH TSP

+4.63 SiH TSP 2 26 05/94 RF0 Bobbin 001 t

0.54 17TH TSP

+12.30 BTH TSP 2 31 05/94 RF0 Bobbin NOI 0.45 18TH TSP

+32.95 8TH TSP 2 43 05/94 RF0 Bobbin 001 1

1.06 3RD TSP

+19.62 8TH TSP 2 57 05/94 RF0 Bobbin 001 15 1.10 7TH TSP

+21.72 8TH TSP 05/94 RF0 Bobbin 001 32 0.95 7TH TSP

+18.56 STH TSP 2 60 05/94 RF0 Bobbin 001 17 0.63 STH TSP

+40.57 8TH TSP 2 76 05/94 RF0 Bobbin ADI 3.79 STH TSP

+15.15 BTH TSP 05/94 RF0 N/L Special Int VOL 0.77 STH TSP

+13.44 STH TSP 05/94 RF0 H/L Special Int VOL 0.97 STH TSP

+11.52 STH TSP 2 89 05/94 RF0 Bobbin 001 27 0.96 11TH TSP

+37.09 81H TSP 2 102 05/94 RF0 Bobbin 001 3

2.23 1BTH TSP

+2.37 BTH TSP 2 105 05/94 RF0 Bobbin 001 8

2.99 1ST TSP

+1.45 BTH TSP 05/94 RF0 H/L Special Int VOL 1.25 1ST TSP

+2.65 1ST TSP 3 14 05/94 RF0 Bobbin DDI 12 3.23 5TH TSP

+14.69 BTH TSP 3 24 05/94 RF0 Bobbin 001 21 1.78 12TH TSP

+27.73 F/L 3 36 05/94 RF0 Bobbin ADI 3.55 2ND TSP

+33.08 BTH TSP 3 43 05/94 RF0 Bobbin ADI 2.58 1ST TSP

+17.30 8TH TSP 05/94 RF0 H/L Special Int VOL 1.03 1ST TSP

+17.54 1ST TSP 3 52 05/94 RF0 Bobbin 001 6

0.85 4TH TSP

+12.71 BTH TSP 3 61 05/94 RF0 Bobbin DDI 28 0.47 7TH TSP

+2.84 BTH TSP 3 63 05/94 RF0 Bobbin No!

0.62 10TH TSP

+9.16 BTH TSP 05/94 RF0 C/L Special Int VOL 1.67 10TH TSP

+9.B4 10TH TSP 3 74 05/94 RFO Bobbin ADI 30.45 STH TSP

+1.65 8TH TSP 05/94 Rr0 H/L Special Int VOL 2.04 STH TSP

+1.55 STH TSP 3 75 05/94 RF0 Bobbin 001 3

5.87 2ND TSP

+16.89 BTH TSP 3 78 05/94 RF0 Bobbin ADI 2.87 13fH TSP

+36.25 BTH TSP 05/94 RF0 C/L Special Int VOL 0.4712TH TSP

-7.10 12TH TSP 3 101 05/94 RF0 Bobbin No!

1.13 12TH TSP

+40.50 STH TSP 05/94 RFC C/L Special Int VOL 1.94 11TH TSP

-2.96 11TH TSP 3 103 05/94 RF0 Bo a#-

NQI 0.31 16TH TSP

+6.90 8TH TSP 05/41 4F0 C/L.rertet Int VOL 0.3616TH TSP

+7.60 16TH TSP 4 8 05/94 RF0 Bobb a ADI 8.50 3RD TSP

+19.17 BTH TSP 05/94 RF0 H/L Special Int VOL 1.19 3RD TSP

+19.48 3RD TSP 4 11 05/94 RF0 Bobbin 001 5

1.03 7TH TSP

+13.68 BTH TSP 4 43 05/94 RF0 Bobbin ADI 5.14 1ST TSP

+5.78 BTH TSP 05/94 RF0 H/L Special Int VOL 1.05 IST TSP

+5.77 1ST TSP 4 49 05/94 RF0 Bobbin 001 25 0.66 7TH TSP

+7.36 BTH TSP 4 54 05/94 RF0 Bobbin ODI 19 1.13 7TH TSP

+12.81 BTH TSP 05/94 RF0 Bobbin 001 21 0.66 7TH TSP

+18.18 BTH TSP

I BWNS TUBAN 11 (Version 2.0) 06/17/1994 06:22:10 Catawba Nuclear Station - Unit Two e.**************************

S/G B e.**************************

05/94 RF0 Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U-Bend Page 2 of 21 S/G B - ATTACHMENT #2 INDICATIONS OF IMPERFECTIONS e

ROW COL OUTAGE TEST TYPE IND %TW VOLTS LOCATION EXTENT 1 4 55 05/94 RF0 Bobbin ADI 5.41 8TH TSP

+8.04 BTH TSP 05/94 RF0 U Bend VOL 1.35 9TH TSI

+1.11 9TH TSP 05/94 RF0 Bobbin 001 6

0.53 6TH TSP

+35.51 8TH T$o 4 59 05/94 RF0 Bobbin ADI 1.47 71H TSP

+24.99 8TH TSP 05/94 RF0 Bobbin ADI 2.88 7TH TSP

+12.52 8TH TSP 05/94 RF0 Bobbin ADI 5.20 7TH TSP

+32.96 8TH TSP 05/94 RF0 Bobbin ADI 7.87 TTH TSP

+16.71 BTH TSP 05/94 RF0 H/L Special Int VOL 0.33 7TH TSP

+11.09 8TH TSP 05/94 RTO H/L Special Int VOL 0.62 7TH TSP

+31.80 8TH TSP 05/94 RF0 H/L Special Int VOL 0.68 7TH TSP

+17.91 8TH TSP 05/94 RF0 H/L Special Int VOL 1.20 7TH TSP

+14.85 BTH TSP 05/94 RF0 H/L Special Int VOL 2.37 7TH TSP

+23.50 81H TSP 4 73 05/94 RF0 Bobbin ODI 14 4.32 STH TSP

+4.46 BTH TSP 4 93 05/94 RF0 Bobbin ADI 1.47 12TH TSP

+28.01 87H TSP 05/94 RF0 C/L Special Int VOL 0.46 11TH TSP

-16.55 11TH TSP 4 106 05/94 RF0 Bobbin NQI 1.20 4TH TSP

+12. 73 87H TSP 05/94 RF0 H/L Special Int VOL 1.16 4TH TSP

+11.37 4TH TSP 5 1 05/94 RF0 Bobbin 001 2

1.22 10TH TSP

+42.39 F/L 5 3 05/94 RF0 Bobbin 001 5

1.08 10TH TSP

+42.68 F/L 5 19 05/94 RF0 Bobbin r51 2

0.85 10TH TSP

+26.93 F/L 5 23 05/94 RTO Bobbin J01 1

2.65 10TH TSP

+13.06 F/L 05/94 RF0 Bobbin 001 13 0.7311TH TSP

+21.02 F/L 5 47 05/94 RF0 Bobbin 001 24 0.5716TH TSP

+15.19 F/L 5 51 05/94 RF0 Bobbin 001 2

0.45 14TH TSP

+6.55 F/L 5 53 05/94 RF0 Bobbin NQI 0.36 7TH TSP

+14.42 F/L 5 60 05/94 RF0 Bobbin 7"

10 1.19 7tW TSP

+19.36 F/L 5 72 2?/94 RF0 Bobbia ADI 5.91 13"+ Ts9

+7.78 F/L 05/9* AFO C/L Special Int VOL 0.98 13TH TSP

+7.95 13TH TSP 5 89 05/94 RF0 Bobbin No!

0.45 2ND TSP

+9.56 F/L 05/94 RF0 H/L Special Int VOL 0.91 2ND TSP

+9.76 2ND TSP 6 5 05/94 RF0 Bobbin 001 10 0.27 14TH TSP

+4.62 F/L 6 7 05/94 RF0 Bobbin NO!

0.46 16TH TSP

+8.68 F/L 05/94 RF0 Bobbin 001 2

1.00 13fH TSP

+31.75 F/L 05/94 RF0 Bobbin 001 4

1.10 10TH TSP

+42.62 F/L 05/94 RFO Bobbin 001 6

1.51 13TH TSP

+35.52 F/L 05/94 RF0 Bobbin 001 7

1.83 12TH TSP

+1.57 F/L 05/94 RF0 C/L Special Int VOL 2.18 16TH TSP

+8.68 16TH TSP 6 9 05/94 RF0 Bobbin 001 37 0.40 10TH TSP

+32.86 F/L 05/94 RF0 C/L Special Int VOL 2.11 9TH TSP

-12.49 91H TSP 05/94 RF0 C/L Special Int VOL 3.46 9TH TSP

-9.74 9TH TSP 6.11 05/94 RF0 Bobbin 001 7

0.61 10TH TSP

+43.26 F/L 6 14 05/94 RF0 Bobbin No!

0.76 2ND TSP

+17.35 F/L 05/94 RF0 H/L Special Int VOL 1.33 2ND TSP

+18.08 2ND TSP 6 15 05/94 RF0 Bobbin 001 3

0.59 10TH TSP

+42.62 F/L 6 16 05/94 RF0 Bobbin 001 18 0.29 2ND TSP

+17.36 F/L 6 41 05;14 RF0 Bobbin 001 34 0.6710TH TSP

+29.91 F/L 6 47 05/94 RF0 Bobbin 001 31 0.59 10TH TSP

+42.01 F/L 6 51 05/94 RF0 Bobbin 001 8

0.60 10TH TSP

+38.70 F/L 05/94 RF0 Bobbin 001 16 0.26 11TH TSP

+11.02 F/L 05/94 RF0 Bobbin 001 20 1.0710TH TSP

+26.05 F/L 7 6 05/94 RF0 Bobbin 001 19 0.96 13fH TSP

+27.49 F/L 7 19 05/94 RF0 Bobbin 001 24 0.62 10TH TSP

+26.96 F/L 7 26 05/94 RF0 Bobbin 001 3

0.64 4TH TSP

+22.53 F/L l

05/94 RF0 Bobbin 001 12 0.96 3RD TSP

+21.39 F/L 7 36 95/94 RFC Bobbin NQI 0.65 11TH TSP

+13.41 F/L 05/94 RF0 C/L Special Int VOL 2.07 11TH TSP

+13.41 11TH TSP 7 51 05/94 RF0 Bobbin Not 0.76 10TH TSP

+3.13 F/L j

05/94 RFO Bobbin 001 22 0.38 7TH TSP

+ 0. 73 F/L l

05/94 RF0 H/L Special Int VOL 0.38 7tH TSP

+1.91 7TH TSP i

7 52 05/94 RF0 Bobbin No!

0.32 77H TSP

+21.11 F/L 05/94 RF0 Bobbin NCI 0.40 7TH TSP

+25.01 F/L 05/94 RTO Bobbin ADI 2.89 11TH TSP

+36.49 F/L 05/94 RF0 Bobbin NQI 0.33 10TH TSP + 29. 55 F/L 05/94 RF0 Bobbin 001 7

1.11 7TH TSP

+18.26 F/L 05/94 RF0 Bobbin 001 25 1.35 7TH TSP

+20.69 F/L 05/94 RF0 Bobbin 001 22 0.23 10TH TSP

+8.62 F/L i

BWNS TUBAN 11 (Version 2.0) 06/17/1994 06:22:10 ese.eee**.eeee...eee********

Catawba Nuclear Station - Unit Two e..........................

sja g 05/94 RF0 Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U-Bend e..........*****************

Page 3 of 21 S/G B - ATTACHMENT #2 INDICATIONS OF IMPERFECTIONS ROW COL OUTAGE TEST TYPE IND %TW VOLTS LOCATION EXTENT 1 05/94 RF0 C/L Special Int VOL 0.45 9TH TSP 11.97 9TH TSP 05/94 RF0 H/L Special Int VOL 2.97 7TH TSP

+23.41 7TH TSP 05/94 RF0 C/L Special Int VOL 0.71 10TH TSP

-6.08 10TH TSP 7 54 05/94 RF0 Bobbin NQI 0.38 7TH TSP

+24.16 F/L 05/94 RF0 H/L Special Int VOL 0.28 BTH TSP

-17.77 BTH TSP 7 61 05/94 RF0 Bobbin 001 2

0.92 Sid TSP

+7.56 F/L 7 82 05/94 RF0 Bobbin ODI 8

3.01 19TH TSP

-2.89 F/L 7 95 05/94 RF0 Bobbin DDI 15 1.01 7TH TSP

+29.66 F/L 05/94 RF0 Bobbin DDI 15 0.45 10TH TSP

+40.72 F/L 05/94 RF0 C/L Special Int YOL 0.64 97H TSP

-5.61 9TH TSP 710105/94 RF0 Bobbin ADI 1.18 157H TSP

-4.16 F/L 05/94 RF0 C/L Special Int VOL 1.82 15fH TSP 4.92 1STH TSP 8 29 05/94 RF0 Bobbin 001 4

2.81 STH TSP

+33.46 F/L 8 37 05/94 RF0 Bobbin NQI 0.37 2ND TSP

+12.05 F/L 05/94 RF0 H/L Special Int VOL 0.58 2ND TSP

+9.95 2ND TSP 05/94 RF0 H/L Special Int VOL 0.87 2ND TSP

+12.12 2ND TSP 8 43 05/94 RF0 Bobbin 001 4

0.66 10TH TSP

+14.25 F/L 8 85 05/94 RF0 Bobbin 001 21 0.95 11TH TSP

+2.76 F/L 8 93 05/94 RF0 Bobbin ADI 3.10 TTS CL

+3.11 F/L 05/94 RF0 C/L Special Int VOL 0.57 TTS-CL

+3.11 TTS-HL 05/94 RF0 C/L Special Int VOL 0.56 TTS-CL

+3.75 to

+7.00 TTS-HL 8 95 05/94 RF0 Bobbin ADI 1.52 10TH TSP

+34.05 F/L 05/94 RF0 Bobbin ADI 1.98 10TH TSP

+35.23 F/L 8 103 05/94 RF0 Bobbin ADI 9.55 14TH TSP

+2.94 F/L 05/94 RF0 C/L Special Int VOL 0.76 14TH TSP

+2.54 14TH TSP 8 112 05/94 RF0 Bobbin ADI 4.55 1ST TSP

+1.92 F/L 05/94 RF0 H/L Special Int VOL 0.60 1ST TSP

+2.47 1ST TSP 9 2 05/94 RF0 Bobbin 001 37 0.90 10TH TSP

+28,86 F/L 05/94 RF0 C/L Special Int VOL 0.68 9TH TSP

-7.05 9TH TSP 05/94 RF0 C/L Special Int VOL 2.64 9TH TSP

-13.74 9TH TSP 9 4 05/94 RF0 Bobbin NQI 0.39 10TH TSP

+42.51 F/L 05/94 RF0 C/L Special Int VOL 1.51 9TH TSP

-3.32 9tH TSP 9 9 05/94 RF0 Bobbin 001 14 0.66 18TH TSP

+3.27 F/1 05/94 RF0 C/L Special Int VOL 2.79 18TH TSP

+3.27 18TH TSP 9 11 05/94 RF0 Bobbin 001 1

1.09 10TH TSP

+31.99 F/L 05/94 RF0 C/L Special Int VOL 0.94 97H TSP

-10.61 9TH TSP 9 15 05/94 RF0 Bobbin 001 15 0.42 10TH TSP

+39.91 F/L 05/94 RF0 C/L Special Int VOL 0.64 9TH TSP

-6.42 9TH TSP 9 17 05/94 RF0 Bobbin 001 14 0.94 10TH TSP

+43.84 F/L 9 22 05/94 RF0 Bobbin 001 6

0.73 2ND TSP

+14.77 F/L 9 46 05/94 RF0 Bobbin 001 14 0.48 4TH TSP

+18.30 F/L 9 47 05/94 RF0 Bobbin NQI 1.33 2ND TSP

+14.61 F/L 05/94 RF0 H/L Special it;t VOL 1.54 2ND TSP

+ 17.39 2ND TSP 9 70 05/94 RF0 Bobbin ADI 5.46 7TH TSP

+13.50 F/L 05/94 RF0 Bobbin 001 4

1.10 10TH TSP

-5.84 F/L 9 85 05/94 RF0 Bobbin NQI 1.24 1ST TSP

+11.48 F/L 05/94 RF0 H/L Special Int VOL 1.22 iST TSP

+12.88 1ST TSP 9 94 05/94 RF0 Bobbin NOI 0.87 4TH TSP

+19.67 F/L 05/94 RTO H/L Special Int VOL 1.82 4TH TSP

+19.5 7 4TH TSP 9 112 05/94 RF0 Bobbin 001 21 0.92 17TH TSP

+7.59 F/L 10 6 05/94 RF0 Bobbin NQI 0.68 18TH TSP

+12.71 F/L 05/94 RF0 Bobbin 001 11 0.52 10TH TSP

+30.17 F/L 05/94 RF0 C/L Special Int VOL 4.3' 9TH TSP

-14.60 97H TSP

[

05/94 RFC C/L Special Int VOL 2.53 181H TSP

+11.15 1BTH TSP 05/94 RF0 C/L Special Int VOL 2.93 18TH TSP

+12.71 18TH TSP 10 17 05/94 RF0 Bobbin NQ1 1.15 6TH TSP

+14.77 F/L 05/94 RF0 H/L Special Int VOL 1.34 STH TSD

+15 34 6TH TSP 10 19 05/94 RF0 Sebbin 001 2

1.08 10TH TSP

+43.89 F/L 10 22 05/94 RF0 Bobbin 0D! 20 0.27 9TH TSP

-0.11 F/L 10 40 05/94 RF0 6obbin AD 2.6% IST TSP

+25.78 F/L 10 47 05/94 RF0 Bobbin ADI 2.02 18TH T5P

+5.84 F/L 05/94 RF0 C/L Special Int VOL 0.66 18TH TSP

+5.59 18TH TSP 10 54 05/94 RF0 Bobbin NQI 0.35 18TH TSP

+0.15 F/L 10 70 05/94 RF0 Bobbin h31 0.40 13fH TSP

+1.97 F/L

)

05/94 RF0 Bobbin 001 8

0.83 13TH TSP

+6.25 F/L

-10 103 05/94 RF0 Bobbin 001 12 1.84 STH TSP

+26.42 F/L 4

BWNS TUSAN 11 (version 2.0) 06/17/1994 06:22:10 Catawba Nuclear Station - Unit Two

              • e.....***.........***

S/G B

          • e*e.ee.........,*******

05/94 RF0 Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U-Bend l

Page 4 of 21 S/G B - ATTACHMENT #2 INDICATIONS OF IMPERFECTIONS ROW COL DUTAGE TEST TYPE IND %TW VOLTS LOCATION EXTENT 1 11 11 05/94 RF0 Bobbin ADI 3.81 STH TSP

+36.85 F/L 05/94 RF0 H/L Special Int VOL 0.73 6TH TSP

-5.45 6TH TSP 11 59 05/94 RF0 Bobbin NQI 0.67 2ND TSP

-8.44 F/L 05/94 RF0 Bobbin NQ!

0.41 13TH TSP

+5.90 F/L 05/94 RF0 Bobbin NOI 1.72 14TH TSP

+5.66 F/L 05/94 RF0 Bobbin 001 14 1.31 11TH TSP

+3.90 F/L 05/94 RF0 Bobbin 001 20 0.72 12TH TSP

+19.48 F/L 05/94 RF0 Bobbin 001 20 1.46 1STH TSP

+ 5. 64 F/L 05/94 RF0 H/L Special Int VOL 0.58 2ND TSP

-B.19 2ND TSP 05/94 RF0 C/L Special Int VOL 0.40 15fH TSP

+7.06 1STH TSP 05/94 RF0 C/L Special Int VOL 0.55 13TH TSP

+6.72 13TH TSP 05/94 RFC C/L Special int VOL 0.85 14TH TSP

+5.53 14TH TSP 05/94 RF0 C/L Special Int VOL 0.92 14TH TSP

+6.23 14TH TSP 05/94 RF0 C/L Special Int VOL 1.16 14TH TSP 41.71 14TH TSP 05/94 RF0 C/L Special Int VOL 1.89 14TH TSP

+5.20 14TH TSP 12 6 05/94 RF0 Bobbin 001 1

0.44 10TH TSP

+34.55 F/L 12 16 05/94 RF0 Bobbin NQ1 0.40 tith TSP

+15.99 F/L 12 22 05/94 RF0 Bobbin NQ1 0.83 9TH TSP

+1.35 F/L 12 23 05/94 RF0 Bobbin 001 26 0.78 9TH TSP

+1.28 F/L 12 25 05/94 RF0 Bobbin ODI 22 1.05 9TH TSP

+1.95 F/L 12 31 05/94 RF0 Bobbin ADI 11.31 11TH TSP

+36.26 F/L 05/94 RF0 C/L Special Int VOL 0.65 10TH TSP

-7.68 10TH TSP 12 32 05/94 RF0 Bobbin NCI 1.96 4TH TSP

+5.26 F/L 05/94 RF0 H/L Special Int VOL 2.52 4TH TSP

+5.59 4TH TSP 12 33 05/94 RF0 Bobbin ODI 9

0.41 11TH TSP

+26.64 F/L 05/94 RF0 Bobbin 001 31 0.30 10TH TSP

+31.84 F/L 12 41 05/94 RFC Bobbin 001 11 1.05 10TH TSP

+9.69 F/L 12 52 05/94 S*O Bobbin 001 1

1.51 12TH TSP

+34.49 F/L 05/94 PF0 Botbin 001 12 0.72 10TH TSP

+28.03 F/L 12 88 05/94 RFi e,svin NQ1 0.40 10TH TSP

+25.95 F/L 05/94 RiJ C/L Special Int VOL 1.14 10TH TSP

+25.78 10TH TSP 12 91 05/94 RF0 Bobbin No!

0.36 7TH TSP

+19.40 F/L 05/94 RF0 Bobbin NQI 0.38 10TH TSP

+12.68 F/L 05/94 RF0 Bobbin No!

0.38 10TH TSP

+12.68 F/L 05/94 RF0 Bobbin 001 1

0.44 7TH TSP

+15.89 F/L 05/94 RF0 Bobbin 001 15 0.76 7TH TSP

+11.69 F/L 12 93 05/94 RF0 Bobbin 001 1

1.79 10TH TSP

+44.66 F/L 12 109 05/94 RF0 Bobbin ODI 12 0.93 10TH TSP

+33.04 F/L 13 10 05/94 RF0 Bobbin 001 10 1.65 4TH TSP

+22.35 F/L 13 11 05/94 RF0 Bo' bin 001 19 0.68 9TH TSP 2.07 F/L 13 18 05/94 RFO Bobbin KQI 0.37 11TH TSP

+19.80 F/L 05/94 RF0 Bobbin DDI 1

0.80 4TH TSP

+3.08 F/L 05/94 RF0 Bob 5in 001 19 0.28 15TH TSP

+2.77 F/L 13 43 05/94 RF0 Bobbin 001 33 0.37 13TH TSP

+22.76 F/L 13 44 05/94 RF0 Bobbin ADI 6.86 7TH TSP

+5.49 F/L t

05/94 RF0 Bobbin ADI 8.79 3RD TSP

+13.63 F/L 05/94 RF0 Bobbin ADI 2.98 12TH TSP

+22.86 F/L 05/94 RFC H/L Special Int VOL 1.00 3RD TSP

+14.20 3Rt TSP 05/94 RF0 H/L Special Int VOL 1.55 7TH TSP

+6.07 7 H TSP 4

05/94 RF0 C/L Special Int VOL 0.49 12TH TSP

+22.63 12TH TSP 13 50 05/94 RF0 Bobbin NOI 1.56 6TH TSP

+24.77 F/L 05/94 RF0 H/L Special Int VOL 0.60 6TH TSP

+21.10 6TH TSP 13 60 05/94 RF0 Bobbin ADI 5.67 13TH TSP

+15.44 to +20.38 F/L 05/94 RF0 C/L Special Int VOL 0.39 13TH TSP

+16.62 13TH TSP 05/94 RF0 C/L Special Int VOL 0.58 13TH TSP

+19.68 13TH TSP 05/94 RF0 C/L Special Int VOL 0.63 13TH TSP

+18.12 13TH TSP 05/94 RF0 C/L Speelal Int VOL 0.63 13TH TSP

+21.00 13TH TSP 13 79 05/94 RF0 Bobbin H Q '.

0.48 10TH TSP

+29.78 F/L 05/94 RF0 C/L Special int V0.

1.02 91H TSP

-17.26 97H TSP 13 89 05/94 RF0 Bobbin ACI 4.51 1ST TSP

-5.17 F/L 05/94 RF0 H/L Special Int VOL 0.79 1ST TSP

-4.75 151 TSP t

13 93 05/94 RF0 Bobbin ADI 2.97 IST TSP

+2.47 F/L 05/94 RF0 H/L Special irt VOL 0.75 1ST TSP

+2.78 1ST TSP 13 96 05/94 RF0 Bobbin No!

0.65 12TH TSP

+14.42 F/L 05/94 RF0 C/L Special Int VOL 0.76 12TH TSP

+15.40 12TH TSP 13 99 05/94 RF0 Bobbin No!

0.21 TTH TSP

+30.68 F/L

.-~

      • ese*** ******************

BWNS TUBAN 11 (Version 2.0) 06/17/1994 06:22:10

                  • e**eeeeeeeeeeee.e**

Catawba Nuclear Station - Unit Two sfg g

      • enee*********************

05/94 RF0 Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U-Bend

    • ee************************

Page 5 of 21 S/G B - ATTACHMENT #2 IN01 CATIONS OF IMPERFECTIONS ROW COL OUTAGE TEST TYPE IND %TW VOLTS LOCATION FXTENT1 05/94 RF0 Bobbin N01 0.42 9TH TSP

-0.56 F/L 05/94 RF0 H/L Special Int VOL 0.53 BTH TSP

-12.27 BTH TSP 13 100 05/94 RF0 Bobbin ADI 2.89 1ST TSP

+24.21 F/L 05/94 RF0 Bobbin ADI 3.54 STH TSP

+17.76 F/L 05/94 RF0 Bobbin ADI 2.03 16TH TSP

+9.35 F/L 05/94 RF0 H/L Special Int VOL 0.60 STH TSP

+17. 64 STH TSP 05/94 RF0 H/L Special Int VOL 0.61 2ND TSP 5.49 2ND TSP 05/94 RF0 C/L Special Int VOL 0.33 16TH TSP

+9.31 16TH TSP 13 104 05/94 RF0 Bobbin 001 6

1.09 STH TSP

+28.41 F/L 14 3 05/94 RF0 Bobtin No!

0.53 11TH TSP

+41.48 F/L 14 ~ 05/94 RF0 Bobbin 001 18 1.06 9TH TSP

-2.80 F/L 05/94 RF0 Bobbin 001 30 0.93 10TH TSP

+12.97 F/L 14 9 05/94 RF0 Bobbin NQI 0.62 12TH TSP

+ 8. 75 F/L 05/94 RF0 C/L Special Int VOL 3.24 12TH TSP

+9.24 12TH TSP 14 12 05/94 RF0 Bobbin 001 16 0.48 12TH TSP

+11.00 F/L 05/94 RF0 C/L Special Int VOL 2.64 12TH TSP

+17.93 12TH TSP 05/94 RF0 C/L Special Int VOL 2.84 12TH TSP

+12.77 12TH TSP 05/94 RF0 C/L Special int VOL 3.03 12TH TSP

+15.48 12TH TSP 05/94 RF0 C/L Special Int VOL 3.59 12TH TSP

+11.00 12TH TSP 05/94 RF0 C/L Special Int VOL 3.80 12TH TSP

+14.32 12TH TSP 05/94 RF0 C/L Speciai Int VOL 4.80 12TH TSP

+16.99 12TH TSP 14 31 05/94 RF0 Bobbin DDI 8

0.97 10TH TSP

+41.39 F/L 14 34 05/94 RF0 Bobbin 001 6

1.25 STH TSP

+24.93 F/L 14 53 05/94 RF0 Bobbin ODI 14 0.3714TH TSP

+9.41 F/L 14 55 05/94 RF0 Bobbin 001 15 0.64 12TH TSP

+23.90 F/L 14 59 05/94 RF0 Bobbin NQI 0.43 10TH TSP

+41.14 F/L 05/94 RF0 Bobbin ODI 3

1.26 10TH TSP

+36.83 F/L 05/94 RF0 C/L Special Int VOL 0.40 9TH TSP

-4.76 97H TSP 05/94 RF0 C/L Special Int VOL 0.78 97H TSP 3.58 9TH TSP 05/94 RF0 C/L Special Int VOL 0.94 9TH TSP

-9.22 9TH TSP 05/94 RF0 C/L Special Int VOL 1.67 9TH TSP

-8.08 9TH TSP Bo' bin 001 4

0.67 7TH TSP

+39.84 F/l 14 80 05/94 RF0 o

05/94 RFC H/L Special Int VOL 1.53 BTH TSP

-2.04 BTH TSP 14 89 05/94 RF0 Bobbin ADI 4.51 161H TSP

+9.47 F/L 05/94 RF0 C/L Special Int VOL 0.56 16TH TSP

+10.16 16TH TSP 14 92 05/94 RF0 Bobbin NQI 1.15 7TH TSP

+10.55 F/L 05/94 RF0 H/L Special Int VOL 1.22 7TH TSP

+11.26 TTH TSP 14 96 05/94 RF0 Bobbin ADI 2.13 8TH TSP

-2.66 F/L 05/94 RF0 Bobbin 001 24 0.57 9TH TSP 6.78 F/L 05/94 RF0 H/L Special Int VOL 0.96 8TH TSP

-2.58 8TH TSP 14 99 05/94 RF0 Bobbin 001 12 0.89 9TH TSP

-6.41 F/L 05/94 RF0 C/L Special Int VOL 0.14 97H TSP

-3.39 9TH TSP 05/94 RF0 C/L Special Int VOL 0.64 9TH TSP 2.08 9TH TSP 05/94 RF0 C/L Special Int VOL 0.64 9TH TSP

-6.79 9TH TSP 05/94 RF0 C/L Special Int VOL 1.32 9TH TSP

-5.66 9TH TSP 14 105 05/94 RF0 Bobbin 001 14 1.64 1ST TSP

+6.72 F/L 05/94 RF0 H/L Special Int VOL 1.54 1ST TSP

+6.54 1ST TSP 14 106 05/94 RF0 Bobbin 001 9

2.71 4TH TSP

+33.80 F/L 05/94 RF0 Bobbin ODI 3

3.18 11TH TSP

-6.31 F/L 05/94 RF0 Bobbin ODI 17 1.7011TH TSP

+7.27 F/L 14 107 05/94 RFO Bobbin ADI 1.94 4TH TSP

-7.59 F/L 05/94 RFO H/L Special Int VOL 0.90 4TH TSP

-7.37 4TH TSP 14 112 05/94 RF0 Bobbin 001 8

1.86 97H TSP

-1.39 F/L 05/94 RF0 C/L Special Int VOL 0.95 9TH TSP

-2.59 9TH TSP 05/94 RF0 C/L Special Int VOL 2.28 9TH TSP

-1.37 9TH TSP

~

15 5 05/94 RF0 Bobbin 001 9

0.95 10TH TSP

+43.97 F/L

)

15 7 05/94 RF0 Bobbin 001 11 0.43 BTH TSP

  • 1.31 F/L 15 14 05/94 RF0 Bobbin 001 4

0.77 13TH TSP

+22.88 F/L 15 35 05/94 RF0 Bobbin ADI 2.39 12TH TSP

+25.39 F/L 05/94 RF0 Bobbin NQI 0.82 11TH TSP

+7.14 F/L 05/94 RF0 C/L Special Int VOL 0.49 11TH TSP

+10.51 11TH T**

05/94 RF0 C/L Special Int VOL 0.71 11TH TSP

-16.79 10TH TSP 05/94 RF0 C/L Special Int VOL 0.72 11TH TSP

+7.44 11TH TSP 15 38 05/94 RF0 Bobbin 001 30 0.22 3RD TSP

+22.00 F/L 15 43 05/94 RF0 Bobbin 001 30 0.56 10TH TSP

+37.48 F/L 15 55 05/94 RF0 Bobbin ODI 34 0.42 7TH TSP

+28.83 F/L

BWNS TUBAN !! (Version 2.0) 06/17/1994 06:22:10 eeeeeeeeeeeeeeeeeeeeeeeeeee*

Catawba Nuclear Station - Unit Two me****e................u..

$fg g

                                                  • 2**

t see....................****

05/94 RFO Bobbin,C/L Special Interest,H/L fpecial Interest,H/L Tubesheet,U-Bend ee**************************

Page 6 of 21 S/G B - ATTACHMENT #2 INDICATIONS OF IMPERFECTICNS ROW COL OUTAGE TEST TYPE IND %TW VOLTS LOCATION EXTENT 1 05/94 RF0 Bot in 001 10 0.60 10TH TSP

+27.15 F/L 15 70 05/94 RF0 Bobbin 001 7

1.56 12TH TSP

+31.00 F/L 05/94 RF0 C/L Special Int VOL 0.41 11TH TSP

-16.84 11TH TSP 05/94 RF0 C/L Special Int VOL 0.70 11TH TSP

-14.88 11TH TSP 05/94 RF0 C/L Special Int VOL 1.44 11TH TSP

-13.10 11TH TSP 15 79 05/94 RF0 Bobbin 001 10 1.36 ISTH TSP

+2.34 F/L 15 91 05/94 RF0 Bobbin 001 16 0.93 10TH TSP

+39.52 F/L 15 94 05/94 RF0 Bobbin 001 7

0.82 9TH TSP

-1.05 F/L 05/94 RF0 C/L Special Int VOL 0.30 9TH TSP

-1.24 9TH TSP 15 111 05/94 RF0 Bobbin 001 13 0.58 7TH TSP

+38.37 F/L 16 21 05/94 RF0 Bobbin ODI 23 0.64 9TH TSP

-6.71 F/L 16 23 05/94 RF0 Bobbin 001 10 1.25 91H TSP

-6.10 F/L 16 47 05/94 RF0 Bobbin ADI 5.87 7TH TSP

+9.87 F/L 05/94 RF0 H/L Special Int VOL 1.01 7TH TSF

+11.24 7TH TSP 16 51 05/94 RFO Bobbin ADI 5 d 2 6TH TSP

+29.65 F/L 05/94 RF0 H/L Special Int VOL 1.25 7TH TSP

-11.06 7TH TSP 16 59 05/94 RF0 Bobbin 001 12 1.64 1ST TSP

+22.60 F/L 16 86 05/94 RF0 Bobbin ADI 8.53 4TH TSP

+3.76 F/L 05/94 RF0 H/L Special Int VOL 1.75 4TH TSP

+4.23 4TH TSP 16 89 05/94 RF0 Bobbin ADI 3.84 11TH TSP

+36.07 F/L 05/94 RF0 C/L Special Int VOL 0.58 10TH TSP 0.06 10TH TSP 16 104 05/94 RF0 Bobbin ADI 7.20 4TH TSP

+8.86 F/L 05/94 RF0 Bobbin ADI 8.58 3RD TSP

+25.66 F/L 05/94 RF0 H/L Special Int VOL 0.85 4TH TSP

+3.60 4TH TSP 05/94 RF0 H/L Special Int VOL 0.95 4TH TSP

+8.80 4TH TSP 05/94 RF0 H/L Special Int VOL 1.13 4TH TSP

-1.45 4TH TSP 05/94 RF0 H/L Special Int VOL 1.71 4TH TSP

-9.12 4TH TSP 17 10 05/94 RF0 Bobbin No!

1.24 10TH TSP

+14.75 F/L 05/94 RF0 C/L Special Int VOL 7.68 10TH TSP

+14.75 10TH TSP 17 19 05/94 RF0 Bobbin 001 5

1.40 10TH TSP

+43.51 F/L 17 22 05/94 RF0 Bobbin ODI 17 0.63 11TH TSP

+18.52 F/L 17 29 05/94 RF0 Bobbin No!

0.70 9TH TSP

-1.34 F/L 05/94 RF0 C/L Special Int VOL 0.33 91H TSP

-1.27 91H TSP 17 33 05/94 RF0 Bobbin 001 26 0.76 3RD TSP

+31.51 F/L 17 55 05/94 RF0 Bobbin 001 25 0.91 STH TSP

+23.25 F/L 17 56 05/94 RF0 Bobbin 001 23 1.14 7TH TSP

+31.33 F/L 05/94 RF0 Bobbin 001 28 1.46 STH TSP

-1.84 F/L 17 58 05/94 RF0 Bobbin 001 15 0.92 12TH TSP

+3.01 F/L 17 60 03/94 RF0 Bobbin ADI 1.23 9TH TSP

-2.92 F/L 05/94 RF0 Bobbin ADI 1.79 4TH TSP

-5.62 F/L

,y 05/94 RF0 C/L Special Int VOL 0.49 9TH TSP

-3.96 9TH TSP 05/94 RF0 H/L Special Int VOL 0.67 4TH TSP

-6.41 4TH TSP 17 66 05/94 RF0 Bobbin-ADI 7.36 3RD TSP

+8.10 F/L j

05/94 RF0 H/L Special Int VOL 0.95 3RD TSP

+9.11 3RD TSP j

18 4 05/94 RF0 Bobbin Not 0.40 10TH TSP

+30.70 F/L i

05/94 R.'O Bobbin 001 14 1.37 10TH TSP

+22.25 F/L l

05/94 RF0 Bobbin 001 18 0.66 10TH TSP

+41.56 F/L 3

18 6 05/94 RF0 Bobbin ADI 6.22 3RD TSP

+14.26 F/L l

05/94 RF0 Bobbin 001 37 2.24 4TH TSP

+37.89 F/L 05/94 RF0 H/L Special Int VOL 0.62 3RD TSP

+15.02 3RD TSP i

05/94 RF0 H/L Special Int VOL 1.55 STH TSP

-4.75 STH TSP 18 15 05/94 RF0 Bobbin ADI 2.4812TH TSP

+19.58 F/L y

05/94 RF0 C/L Special Int VOL 3.15 12TH TSP

+19.58 12TH TSP i

18_19 05/94 RF0 Cobbin Ncl 0.35 11TH TSP

+30.37 F/L 05/94 RF0 Bobbin 001 13 0.54 11TH TSP

+25.26 F/L 05/94 RF0 Bobbin 001 14 0.53 11TH TSP

+24.04 F/L i

18 20 05/94 RF0 Bobbin ODI 36 1.13 1ST TSP

+15.19 F/L 18 21 05/94 KF0 Bobbin 001 14 4.78 14TH ISP

+5.72 F/L 05/94 RFC C/L Special Int VOL 1.28 14TH TSP

+5.26 14TH TSP j

18 24 05/94 RF0 Bobbin 001 18 1.39 STH TSP

+3.95 F/L

{

18 26 05/94 RF0 Bobbin No!

0.68 STH TSP

+20.44 F/L 05/94 kF0 H/L Spr 'cl Int VOL 1.08 STH TSP

+20.95 STH TSP 05/94 U O H/L 5;

.at Int YOL 1.42 51H TSP

+17.60 STH TSP 18 36 05/94 RF0 Bobbin 001 5

0.50 15TH TSP

+6.06 F/L 18 38 05/94 RF0 Bobbin 001 21 0.39 6TH TSP

+37.56 F/L 05/94 RF0 Bobbin 001 16 0.58 16TH TSP

+10.67 F/L

BWNS TUBAN !! (Version 2.0) 06/17/1994 06:22:10 eeeeeeeeeeeeeeeeee......e***

Catawba Nuclear Station - Unit Two

..e******* eve ***************

eee............ e******e

  • e.

Sjg g 05/94 RF0 Bobbin,C/L Speciat interest,H/L Special Interest,H/L Tubesheet,U Bend Page 7 of 21 S/0 B - ATTACHMEN1 #2 INDICATIONS OF IMPERFECTIONS ROW COL DUTAGE TEST TYPE IND %TW VOLTS LOCATION EXTCNT1 18 48 05/94 RF0 Bebbin 001 12 0.51 2ND TSP

+30.50 F/L 05/94 RF0 Bobbin 001 15 0.50 18TH TSP

+10.14 F/L 18 49 05/94 RF0 Bobbin DDI 5

1.57 13TH TSP

+5.81 F/L 1B 51 05/94 RF0 Bobbin ADI 1.65 2ND TSP

+21.82 F/L 05/94 RF0 Bobbin 001 10 0.80 2ND TSP

+17.56 F/L 18 52 05/v4 RF0 Bobbin DDI 26 0.58 3RD TSP

+34.24 F/L 05/94 RF0 Bobbin 001 22 0.79 11TH TSP

+7.83 F/L 05/94 RF0 Bobbin DDI 29 0.66 11TH TSP

+3.98 F/L 05/94 RF0 H/L Special Int VOL 0.41 4TH TSP

-1.28 4TH TSP 05/94 RF0 C/L Special Int VOL 0.19 11TH TSP

+7.71 11TH TSP 05/94 RF0 C/L Special Int VOL 0.46 11TH TSP

+3.81 11TH TSP 18 53 05/94 RF0 Bobbin ADI 1.33 2ND TSP

+21.31 F/L 18 55 05/94 RF0 Bobbin 001 9

0.82 12TH TSP

+25.92 F/L 05/94 RF0 C/L Special Int VOL 0.56 11TH TSP

-17.10 11TH TSP 18 39 05/94 RF0 Bobbin ADI 2.54 13TH TSP

-1.37 F/L 05/94 RF0 C/L Special Int VOL 0.62 13TH TSP

-1.31 13TH TSP 18 86 05/94 RF0 Bobbin 001 28 2.42 1AVB

+1.99 F/L 18 87 05/94 RFO Bobbin ADI 7.B4 13TH TSP

+38.03 F/L 05/94 RFC C/L Special Int VOL 0.73 12TH TSP

-5.79 12TH TSP 18 88 05/94 RF0 Bobbin ADI 6.28 187H TSP

+13.49 F/L 18 92 05/94 RF0 Bobbin ADI 5.39 7TH TSP

+37.95 F/L 05/94 RF0 H/L Special Int VOL 0.54 BTH TSP

-8.98 BTH TSP 05/94 RF0 H/L Special Int VOL 0.67 BTH TSP

-3,02 STH TIP 05/94 RF0 H/L Special Int VOL 0.87 BTH TSP

-4.87 BTH TSP 18 94 05/94 RFC Bobbin ADI 5.20 7TH TSP

+33.81 F/L 05/94 RF0 Bobbin ODI 10 0.95 7TH TSP

+15.54 F/L 05/94 RF0 H/L Special Int VOL 1.17 BTH TSP

-9.14 8TH TSP 19 7 05/94 RF0 Bobbin 001 14 0.49 71H TSP

+8.67 F/L 19 8 05/94 RF0 Bobbin No!

0.40 6TH TSP

+20.53 F/L 05/94 RFO H/L Special Int VOL 1.53 6TH TSP

+20.82 6TH TSP 19 12 05/94 RF0 Bobbin 001 28 0.80 12TH TSP

+9.51 F/L 05/94 RF0 C/L Special Int VOL 0.63 12TH TSP

+9.06 12TH TSP 19 18 05/94 RF0 Bobbin 001 33 0.42 STH TSP

+26.08 F/L 19 22 05/94 RF0 Bobbin ADI 0.58 10TH TSP

+26.12 F/L 19 33 05/94 RF0 Bobbin ADI 4.16 6TH TSP

+40.57 F/L 05/94 RF0 H/L Special Int VOL 1.03 7TH TSP 5.63 7TH TSP 05/94 RF0 H/L Special Int VOL 1.09 7TH TSP

-1.70 7TH TSP 05/94 RF0 H/L Special Int VOL 1.50 7TH TSP

-9.57 TTH TSP 19 41 05/94 RF0 Bobbin DDI 22 1.21 1ST TSP

+14.36 F/L 19 42 05/94 RF0 Bobbin 001 7

2.71 10TH TSP

+36.52 F/L 19 51 05/94 RF0 Bobbin ADI 2.15 6TH TSP

+21.27 F/L 19 53 05/94 RF0 Bobbin No!

0.24 14TH TSP

+9.77 F/L 05/94 RF0 Bobbin NQI 0.38 14TH TSP

+9.23 F/L 05/94 RF0 Bobbin 001 27 0.43 9TH TSP

+1.96 F/L 05/94 RF0 Bobbin 001 9

0.71 14TH TSP

+10.63 F/L 05/94 RF0 Bobbin 001 12 0.43 11TH TSP

+27.44 F/L 05/94 RF0 C/L Special Int VOL 0.58 14TH TSP

+10.58 14TH TSP 19 55 05/94 RF0 Bobbin 001 20 2.18 10TH TSP

+22.30 F/L 05/94 RF0 C/L Special Int VOL 0.79 10TH TSP

+18.44 to +22.04 10TH TSP 19 56 05/94 RF0 Bobbin DDI 8

1.12 2ND TSP

+18.27 F/L 19 57 05/94 RF0 Bobbin 001 11 1.14 3RD TSP

+30.46 F/L 05/94 RFO 5cbbin 001 2

0.64 13fH TSP

+6.82 F/L 19 75 05/94 RF0 Bobbin ADI 6.24 11TH TSP

+4.45 F/L 05/94 RF0 Bobbin DDI 13 1.20 12TH TSP

+19.86 F/L 05/94 RF0 Bobbin 001 32 2.86 13TH TSP

+6.97 F/L 05/94 RF0 C/L Special Int VOL 1.56 11TH TSP

+5.39 11TH TSP 05/94 RF0 C/L Special Int VOL 1.80 12TH TSP

+22.02 12TH TSP

(

19 83 05/94 Rio Bobbin DDI 24 0.98 3RD TSP

+21.76 F/L 19 87 05/94 RFC Bobbin ADI 2.73 it/B

+16.63 F/L 05/94 RF0 Bobbin No!

0.69 16TH TSP

+4.00 F /l.

05/94 RF0 U-Bend VOL 0.45 1AV3

+15.87 8!H T$P I

05/94 RF0 C/L Special Int VOL 0.60 16TH TS?

+4.40 16TH TSP 19 106 05/94 RF0 Bobbin 001 8

0.85 1AVB

+11.32 F/L 19 109 05/94 RFO Bobbin ADI 4.65 77H TSP

+3.02 F/L 05/94 RFO Bobbin ADI 2.10 10TH TSP

+4.10 F/L 05/94 RF0 C/L Special Int YOL 0.73 10TH TSP

+3.83 10TH TSP

BVNS TUBAN II (Versien 2.0) 06/17/1994 06:22:10 Catawba Nuclear Station - Unit Two

.......e..........**........

Sfg g 05/94 RF0 Esbbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U-Bend Page 8 of 21 S/G B - ATTACHMENT #2 INDICATIONS OF IMPERFECTIONS RDW COL DUTAGE TEST TYPE IND %TW VOLTS LOCATION EXTENT 1 20 6 05/94 RF0 Bobbin 001 15 0.96 1ST TSP

+23.83 F/L 05/94 RF0 Bobbin DDI 5

0.57 10TH TSP

+26.02 F/L 20 13 05/94 RF0 Bcbbin ADI 2.71 11TH TSP

+37.96 F/L 05/94 RF0 C/L Special Int VOL 0.45 10TH TSP

-5.13 10TH TSP 20 17 05/94 RF0 Bobbin N01 0.34 17TH TSP

+3.72 F/L 05/94 RF0 C/L Special Int VOL 0.53 17TH TSP

+3. 72 17TH TSP 20 19 05/94 RF0 Bobbin 001 34 0.65 7TH TSP

+32.19 F/L 20 34 05/94 RF0 Bobbin 001 31 0.51 1ST TSP

+7.65 F/L 20 37 05/94 RF0 Bobbin NQI 0.40 15TH TSP

+11.88 F/L 05/94 RF0 Bobbin No!

0.62 11TH TSP

+38.94 F/L 05/94 RF0 Bobbin NQI 0.82 10TH TSP

+35.14 F/L 05/94 RF0 Bobbin 001 6

1.01 10TH TSP

+14.12 F/L 05/94 RF0 Bobbin 001 32 2.33 11TH TSP

+11.61 F/L 05/94 RF0 C/L Special Int VOL 0.73 9TH TSP

-10.34 97H TSP 05/94 RF0 C/L Special Int VOL 0.26 1STH TSP

+11.57 15TH TSP 05/94 RF0 C/L Special Int VOL 0.61 10TH TSP

-4.00 10TH TSP 20 82 05/94 RF0 Bobbin 001 13 1.10 11TH TSP

+37.52 F/L 20 86 05/94 RF0 Bobbin NOI 0.88 11TH TSP

+13.34 F/L 20 96 05/94 RF0 Bobbin 001 7

6.02 12TH TSP

+27.80 F/L 05/94 RF0 C/L Special Int VOL 0.95 11TH TSP

-17.01 11TH TSP 20 101 05/94 RTO Bobbin NQ1 0.59 2ND TSP 410.05 F/L 05/94 RF0 H/L Special Int VOL 0.30 2ND TSP

+10.73 2ND TSP 20 104 05/94 RFO M/L Tubesheet VOL 0.55 TTS HL

+0.00 TTS-HL 21 20 05/94 RF0 Bobbin Nol 0.49 11TH TSP

+3.61 F/L 05/94 RF0 Bobbin 001 24 2.76 91H TSP

-9.91 F/L 05/94 RF0 C/L Special Int VOL 0.32 11TH TSP

+3.50 11TH TSP 05/94 RF0 C/L Special Int VOL 0.37 11TH TSP

-1.04 11TH TSP 21 30 05/94 RF0 Bobbin No!

0.30 16TH TSP

+14.81 F/L 05/94 RFO C/L Special Int VOL 0.43 15TH TSP

-3.vo 1STH TSP 21 34 05/94 RF0 Bobbin 001 31 0.57191H TSP

+4.35 F/L 21 44 05/94 RF0 Bobbin 001 25 0.96 STM TCP

+21.64 F/L 05/94 RF0 H/L Special Int VOL 0.64 5th TSP

+21.99 STH TSP 21 45 05/94 RF0 Bobbin 001 25 0.31 18TH TSP

+5.83 F/L 05/94 RF0 Bobbin 001 32 0.52 11TH TSP

+36.13 F/L 21 49 05/94 RF0 Bobbin 001 33 1.29 17TH TSP

+5.16 F/L 21 56 05/94 RF0 Bobbin 001 29 3.05 12TH TSP

+24.50 F/L 21 59 05/94 RF0 Bobbin No!

0.83 8TH TSP

+0.32 F/L 21 75 05/94 RF0 Bobbin ADI 4.78 7TH TSP

+33.99 F/L 05/94 RF0 H/L Special Int VOL 0.59 8TH TSP

-9.72 8TH TSP 21 76 05/94 RF0 Bobbin 001 24 4.5619TH TSP

+0.87 F/L 05/94 RF0 C/L Special Int VOL 0.91 191H TSP

+0.48 19TH TSP 21 77 05/94 RF0 Bobbin 001 7

0.67 3RD TSP

+22.53 F/L 21 78 05/94 RF0 Bobbin 001 32 1.74 2ND TSP

+25.23 F/L 21 79 05/94 RF0 Bobbin 001 23 4.0716TH TSP

+13.23 F/L 21 96 05/94 RF0 Bobbin 001 3

1.13 14TH TSP

+13.01 F/L 05/94 RF0 C/L Special Int VOL 0.50 14TH TSP

+14.98 14TH TSP 22 15 05/94 RF0 Bobbin ADI 7.35 12TH TSP

+37.80 F/L 05/94 RF0 C/L Special ent VOL 0.68 11TH TSP

+0.27 11TH TSP 05/94 RF0 C/L Special Int VOL 0.96 11TH TSP

-5.37 11TH TSP 22 28 05/94 RF0 Bobbin ADI 3.66 18TH TSP

+14.29 F/L 05/94 RF0 Bobbin Nol 1.2717TH TSP

-5.40 F/L 05/94 RF0 C/L Special Int VOL 0.44 17TH TSP 4.21 171H TSP 05/94 RF0 C/L Special Int VOL 0.85 17TH TSP

-5.42 17TH TSP 22 30 05/94 RF0 Bobbin ODI 2

1.76 2M0 TSP

+22.56 F/L 22 76 05/94 RF0 Bobbin ADI 1.30 10TH TSP

+42.30 F/L 05/94 RF0 Bobbin ADI 2.93 10fH TSP

+40.14 F/L 05/94 RF0 C/L Special Int VOL 0.59 97H TSP

-1.21 91H TSP 05/94 RF0 C/L Special Int YOL 0.73 ?TH TSP

-8.30 9TH TSP 05/94 RTO C/L Special Int VOL 0.74 9fH TSP

-4.43 9TH TSP 22 97 05/04 RF0 Bobbin 001 30 3.61 390 TSP

+3.14 F/L 22 103 05/94 RF0 Bobbin 001 3

5.69 14TH TSP

-5.45 f/L 22 107 05/94 RF0 Bobbin ADI 18.40 4TH TSP

+36.54 F/L 05/94 RF0 Bobbin 001 4

8.58 TTS ML

+6.04 F/L 05/94 RF0 Bobbin 001 15 2.37 3RD TSP

+ 7.93 F/'

05/94 RF0 Bobbin 001 20 3.44 2ND TSP

+25.20 F/,

05/94 RF0 H/L Special Int VOL 2.53 STH TSP

- 6. 73 STH TSP

BWNS TUBAN II (Version 2.0) 06/17/1994 06:22:10 Catawba Nuclear Station - Unit Two

                                              • +++*

gfa g 05/94 RF0 eee*************************

Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U-Bend Page 9 of 21

$/G B - ATTACHMENT #2 INDICATIONS OF IMPERFECTIONS ROW Col. OUTAGE TEST TYPE IND %TW VOLTS LOCATION EXTENT 1 22 109 05/94 RF0 Bobbin 001 2

0.98 11TH TSP

+35.17 F/L 23 7 05/94 RF0 Bobbin 001 7

2.49 13TH TSP

+31.02 F/L 23 15 05/94 RF0 Bobbin NQI 0.70 1BTH TSP

+15.76 F/L 05/94 RF0 C/L Special Int VOL 0.64 17TH TSP

-2.45 17TH TSP 23 19 05/94 RF0 Bobbin No!

0.58 1ST TSP

+11.21 F/L 05/94 RF0 Bobbin NQ1 0.94 6TH TSP

+30.99 F/L 05/94 RF0 Bobbin 001 8

0.52 6TH TSP

+29.94 F/L 23 25 05/94 RF0 Bobbin ADI 4.36 1AVB

+2.45 F/L 05/94 RF0 U-Bend VOL 0.64 1AVB

+2.63 BTH TSP 05/94 RF0 Bobbin ODI 24 1.17 11TH TSP

+2.84 F/L 05/94 RF0 C/L Special Int VOL 0.52 11TH TSP

+2.65 11TH TSP 23 29 05/94 RF0 Bobbin 001 25 0.62 1STH TSP

+7.49 F/L 05/94 RF0 C/L Special Int VOL 0.17 15TH TSP

+7.23 15TH TSP 23 32 05/94 RF0 Bobbin No!

1.54 12TH TSP

+39.74 F/L 05/94 RF0 Bobbin 001 2

1.03 7TH TSP

+24.56 F/L 05/94 RF0 C/L Special Int VOL 0.53 11TH TSP

-3.47 11TH TSP 23 85 05/94 RF0 Bobbin 001 30 1.08 12TH TSP

+26.36 F/L 23 86 05/94 RF0 Bobbin 001 38 1.94 2ND TSP

-10.00 F/L 05/94 RF0 H/L Special Int VOL 0.29 2ND TSP

-11.64 2ND TSP 05/94 RF0 H/L Special Int VOL 1.41 2ND TSP

-10.15 2ND TSP 23 99 05/94 RF0 Bobbin ADI 4.00 4Avs 5.29 F/L 05/94 RF0 U-Bend VOL 0.84 4AVB

-5.34 4AVB 23 108 05/94 RF0 Bobbin NQI 0.47 1ST TSP

+15.56 F/L 23 109 05/94 RF0 Bobbin 0C1 6

0.62 7TH TSP

+40.68 F/L 24 12 05/94 RF0 Bobbin ODI 1

0.50 18TH TSP

+3.42 F/L 24 24 05/94 RF0 Bobbin 001 24 0.63 2ND TSP

+1.57 F/L 05/94 RF0 H/L Special Int VOL 1.30 2ND TSP

+1.69 2ND TSP 24 49 05/94 RF0 Bobbin NQI 0.62 STH TSP

+41.14 F/L 24 55 05/94 RF0 Bobbin Nol 1.57 10TH TSP

+33.06 F/L 05/94 RF0 Bobbin 001 9

1.43 7TH TSP

+24.96 F/L 05/94 RF0 Bobbin 001 24 1.13 7TH TSP

+31.44 F/L 24 63 05/94 RF0 Bobbin ADI 5.14 17TH TSP

+14.88 F/L 05/94 RF0 C/L Special Int VOL 0.60 16TH TSP

-6.77 16TH TSP 05/94 RF0 C/L Special Int VOL 0.89 16TH TSP

-3.87 16TH TSP 24 68 05/94 RF0 Bobbin 001 14 1.47 19TH TSP

+4.34 F/L 05/94 RF0 C/L Special Int VOL 0.66 19TH TSP

+4.19 19TH TSP 24 91 05/94 RF0 Bobbin ADI 4.58 4TH TSP

+34.57 F/L 05/94 RF0 Bobbin No!

0.32 4TH TSP

+7 78 F/L 05/94 RF0 Bobbin ADI 3.14 12TH TSP

+18.22 F/L 05/94 RF0 Bobbin ADI 3.21 13TH TSP

+35.86 F/L 05/94 RF0 Bobbin ADI 3.75 13TH TSP

+37.45 F/L 05/94 RF0 Bobbin ODI 12 2.77 2ND 1SP

+4.08 F/L 05/94 RF0 Bobbin 001 4

1.32 13TH TSP

+26.59 F/L 05/94 RF0 H/L Special Int VOL 0.80 STH TSP

-8.96 STH TSP 05/94 RF0 H/L Special Int VOL 1.05 4TH TSP

+6.04 4TH TSP 05/94 RF0 H/L Special Int VOL 1.07 4TH TSP

+8.07 4TH TSP 05/94 RF0 C/L Special Int VOL 0.23 12TH TSP

+1.52 12TH TSP 05/94 RF0 C/L Special Int VOL 0.25 12TH TSP

+1.75 12TH TSP 05/94 RF0' C/L Special Int VOL 0.29 12TH TSP 9.11 12TH TSP 05/94 RF0 C/L Special Int VOL 0.53 12TH TSP

+8.67 12TH TSP 05/94 RF0 C/L Special Int VOL 0.55 12TH TSP

-14.23 12TH TSP 05/94 RF0 C/L Spectat Int VOL 0.56 12TH TSP

-7.05 12TH TSP 05/94 RF0 C/L Special Int VOL 0.58 12TH TSP

  • i B.13 12TH TSP 05/o4 RFC C/L Special Int VOL 0.88 12TH TSP

'51.76 12TH TSP 05/94 RF0 C/L Special Int YOL 1.39 12TH TSF

+0.0 12TH TSP 24 93 05/94 RF0 Bobbin ADI 2.50 2ND TSP

+21.30 F/L 05/94 RF0 Bobbin ODI 6

2.15 2ND TSP

+16.33 F/L 05/94 RF0 H/L Special Int VOL 0.59 3RD TSP

-14.61 3RD TSP 05/94 RF0 H/L Special Int VOL 0.89 3RD TSP

-13.44 3RD TSP 05/94 RF0 H/L Special Int VOL 0.96 3RD TSP

-21.74 3RD TSP 24 94 05/94 RF0 Bobbin ODI 25 0.69 2ND TSP

+18.96 F/L i

05/94 RF0 Bobbin 001 1

1.22 12TH TSP

+31.92 F/L 1

24 99 05/94 RF0 Bobbin ADI 3.13 4TH TSP

+2.41 F/L l

05/94 RF0 H/L Special Int VOL 0.47 4TH TSP

+3.29 4TH TSP l

24 105 05/94 RF0 Bobbin ODI 15 1.13 2ND TSP

+17.13 F/L 25 8 05/94 RF0 Bobbin ODI 11 0.93 13TH TSP

+7.97 F/L i

I e........... ***************

BWNS TUBAN II (Version 2.0) 06/17/1994 06:22:10 Catawba Nuclear Station - Unit Two

..+.................e***ese eeeeee...................**.

gfg g eeeee.............**********

05/94 RF0 Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U-Rend 1

Page 10 of 21 S/G B - ATTACHMENT #2 INDICATIONS OF IMPERFECTIONS ROW COL OUTAGE TEST TYPE IND %TW VOLTS LOCATION EXTENT 1 25 42 05/94 RF0 Bobbin No!

0.80 3RD iSP

+11.29 F/L 05/94 RF0 Bobbin NQI 1.35 IST TSP

+1.09 F/L 05/94 RF0 H/L Special Int VOL 0.66 IST TSP

+1.02 iST T$P 25 44 05/94 RF0 Bobbin 001 37 1.32 4TH ISP

+32.15 F/L 25 50 05/94 RF0 Bobbin 001 26 0.96 10TH TSP

+5.21 F/L 25 55 05/94 RF0 Bobbin 001 10 6.82 12TH TSP

+25.39 F/L 05/94 RF0 C/L Special Int VOL 0.5711TH TSP

-17.50 11TH TSP 25 67 05/94 RF0 Bobbin 0D1 20 2.01 4AVB 3.34 F/L 25 75 05/94 RF0 Bobbin 001 6

2.0716TH TSP

+8.05 F/L 25 76 05/94 RF0 Bobbin ADI 13.50171H TSP

+3.87 F/L 05/94 RF0 C/L Special Int VOL 1.12 17TH TSP

+3.13 177H TSP 25 78 05/94 RF0 Bobbin 001 17 0.75 1ST TSP

+ 7. 04 F/L 25 81 05/94 RF0 Bobbin ADI 5.68 12TH TSP

+5.01 to +38.43 F/L 05/94 RF0 C/L $peclat Int VOL 0.50 12TH TSP

+38.68 12TH TSP 05/94 RF0 C/L Special Int VOL 0.59 12TH TSP

+9.40 12TH TSP 05/94 RF0 C/L Special Int VOL 0.8712TH TSP

+36.48 12TH TSP 05/94 RF0 C/L Special Int VOL 1.01 22TH TSP

+30.00 12TH TSP 05/94 RF0 C/L Special Int VOL 1.34 12TH TSP

+5.36 12TH TSP 05/94 RF0 C/L Special Int VOL l.43 12TH TSP

+11.44 12TH TSP 05/94 RF0 C/L Special Int VOL 1.64 12TH TSP

+32.56 12TH TSP 05/94 RFO C/L Special Int VOL 1.71 12TH TSP

+34.72 12TH TSP 25 88 05/94 RF0 Bobbin 001 16 3.43 STH TSP

+20.40 F/L 26 8 05/94 RF0 Bobbin NOI 0.96 6TH TSP

+35.18 F/L 05/94 RF0 H/L Special Int VOL 1.10 7TH TSP

-7.42 7TH TSP 26 12 05/94 RF0 Bobbin 001 21 2.00 8TH TSP

+1.46 F/L l

26 16 05/94 RF0 Bobbin ADI 2.62 19TH TSP

+7.95 F/L 05/94 RF0 C/L Special Int VOL 0.45 19TH TGP

+7.73 19TH TSP i

26 36 05/94 RF0 Bobbin ODI 26 2.23 11T H ' 4P

+1.63 F/L 05/94 RF0 C/L Special Int VOL 0.78 11TH TSP

+1.34 11TH TSP 26 38 05/94 RF0 Bobbin 001 22 2.61 16TH TSP

+7.01 F/L 26 40 05/94 RF0 Bobbin ADI 8.72 1AVB

+6.08 F/L

,t 26 62 05/94 RFC Bobbin 001 19 2.79 12TH TSP

+12.96 F/L 26 66 05/94 RF0 Bobbin NQI 1.17 4TH TSP

+40.94 F/L 05/94 RF0 Bobbin NQI 1.60 2ND TSP

+15.99 F/L 05/94 RFC Bobbin NQI 0.65 12TH TSP + 23. 73 F/L 05/94 RF0 H/L Speclat Int VOL 0.49 STH TSP

-1.93 STH TSP i

05/94 RF0 H/L Special Int VOL 1.86 2ND TSP

+15.50 2ND TSP 05/94 RF0 C/L Specist Int VOL 1.30 12TH TSP

+23.00 12TH TSP 26 83 05/94 RF0 Bobbin NQI 0.44 17TH TSP

+4.16 F/L 05/94 RF0 C/L Special Int VOL 0 94 17TH TSP

+4.47 17TH TSP 26 86 05/94 RF0 Bobbin ADI 2.82 15TH TSP

+8.17 F/L 05/94 RF0 Bobbin 001 30 0.89 16TH TSP

+5.68 F/L 05/94 RF0 C/L Special Int VOL 0.44 1STH TSP

+ 7. 65 15TH TSP 05/94 RF0 C/L Special Int VOL 0.66 15fH TSP

+8.99 15fH TSP 26 105 05/94 RF0 Bobbin 001 7

1.08 BTH TSP

+12.33 F/L 05/94 RF0 U Bend VOL 0.52 8TH TSP

+12.26 8TH TSP 27 10 05/94 RF0 Bobbin 001 18 0.39 11TH TSP

+19.08 F/L 05/94 RF0 Bobbin 001 30 2.58 10TH TSP

+43.20 F/L 27 27 05/94 RF0 Bobbin DDI 11 1.21 7TH 75P

+38.85 F/L 05/94 F(0 Bobbin 001 27 2.55 10TH TSP

+43.54 F/L 27 31 05/94 RF0 Bobbin 001 35 2.89 2hD TSP

-1.28 F/L 05/94 RF0 H/L Special Int VOL 0.58 2ND TSP

-0.95 2ND TSP 27 32 05/94 RF0 Bobbin 001 22 1.53 11TH TSP

+24.78 F/L 05/94 RF0 C/L Special Int VOL 0.60 11TH TSP

+23.60 11TH TSP 27 39 05/94 RF0 Bobbin 001 13 1.17 2ND TSP

+21.91 F/L 27 43 05/94 RF0 Bobbin DDI 1

0.43 12TH TSP

+15.12 F/L 27 50 05/94 RF0 Bobbin 001 24 2.15 18TH TSP

+14.66 F/L 27 $4 05/94 RF0 Bobbin NO!

0.75 3RD TSP

+10.98 F/L 05/94 RF0 Bobbin 001 18 2.80 17TH TSP

+12.30 F/L i

05/94 RF0 Bobbin 001 21 2.10 17TH TSP

+9.94 F/L j

27 59 05/94 RF0 Bobbin ADI 2.81 12TH TSP

+ 2.38 F/L 05/94 RF0 Bobbin 001 16 0.54 7TH TSP

+39.97 F/L 05/94 RF0 C/L Speclat Int VOL 0.34 12TH TSP

+2.94 12TH TSP 27 60 05/94 RF0 Bobbin WAR 28 1.87 2AVB

+0.00 F/L 05/94 RF0 Bobbin No!

0.69 7TH TSP

+40.67 F/L 05/94 RF0 H/L Special Int VOL 0.34 BTH TSP

-2.02 STH TSP l

ee**************************

BWNS TUBAN 11 (Version 2.0) 06/17/1994 06:22:10 e***************************

Catawba Nuclear Station - Unit Two

.u..m......m......um eee.........................

3fg g 05/94 RF0 l

Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U-Bend eeeeee.*********************

Page 11 of 21 S/G B - ATTACHMENT #2 INDICATIONS OF IMPERFECTIONS ROW COL OUTAGE TEST TYPE IND %TW VOLTS LOCATION EXTENT 1 05/94 RF0 H/L Special Int VOL 1.10 87H TSP

-0.90 BTH TSP 1

27 63 05/94 RF0 Bobbin ADI 2.67 15TH TSP

+8.11 F/L 05/94 RF0 C/L Special Int VOL 0.56 1STH TSP

+9.03 15TH TSP 27 68 05/94 RF0 Bobbin 001 8

0.56 7TH TSP 12.99 F/L 05/94 RF0 H/L Special Int VOL 0.66 71H TSP

-13.49 7TH TSP 27 75 05/94 RF0 Bobbin ADI 6.83 BTH TSP

+5.12 F/L 05/94 RF0 U-Bend VOL 0.86 BTH TSP

+5.12 BTH TSP 27 80 05/94 RF0 Bobbin ODI 18 1.30 11TH TSP

+15.26 F/L 27 84 05/94 RF0 Bobbin NQI 1.13 TTH TSP

+19.62 F/L 05/94 RF0 H/L Specist Int VOL 0.18 7TH TSP

+19.13 77H TSP 05/94 RF0 H/L Speclat Int VOL 0.68 7TH TSP

+20.15 7TH TSP 28 35 05/94 RF0 Bobbin ADI 5.04 17TH TSP

+1.88 F/L 05/94 RF0 C/L Special Int VOL 0.66177H TSP

+1.71 17TH TSP 28 42 05/94 RF0 Bobbin ADI 4.96 7TH TSP

+38.08 F/L 05/94 RF0 Bobbin 001 26 2.34 77H TSP

+23.79 F/L 05/94 RF0 H/L Special Int VOL 0.68 BTH TSP

-14.28 BTH TSP 05/94 RF0 H/L Special Int VOL 0.87 BTH TSP

-4.86 8TH TSP 05/94 RF0 H/L Special Int VOL 0.93 BTH TSP

-20.39 8TH TSP 28 52 05/94 RF0 Bobbin ODI 19 1.31 11TH TSP

+27.56 F/L 28 55 05/94 RF0 Bobbin 001 23 1.10 12TH TSP

+22.17 F/L 28 63 05/94 RF0 Bobbin 001 14 1.17 6TH TSP

+27.73 F/L i

28 66 05/94 RF0 Bobbin ODI 26 1.36 18TH TSP

+1.58 F/L 05/94 RF0 C/L Special Int VOL 0.59 18TH TSP

+1.19 1STH TSP l

28 69 05/94 RF0 Bobbin N01 0.66 3RD TSP

+4.54 F/L 05/94 RF0 H/L Special Int VOL 0.48 3RD TSP

+16.01 3RD TSP j

05/94 RF0 H/L Special Int VOL 0.82 3RD TSP

+4.42 3RD TSP 28 81 05/94 RF0 Bobbin ADI 1.42 12TH TSP

+15.01 F/L 05/94 RF0 C/L Special Int VOL 0.50 12TH TSP

+16.85 12TH TSP 28 84 05/94 RF0 Bobbin ADI 4.48 16TH TSP

+ 7.11 F/L 05/94 RF0 C/L Special Int VOL 0.77 16TH TSP

+7.12 16TH TSP i

28 85 05/94 RF0 Bobbin NQI 0.53 87H TSP

+1.02 F/L 28 93 05/94 RF0 Bobbin ODI 25 2.03 1AVB

+15.31 F/L 05/94 RF0 U-Bend VOL 0.66 1AVB

+13.65 2AVB 28 94 05/94 RF0 Bobbin 001 30 2.24 BTH TSP

-3.05 F/L 05/94 RF0 Bobbin 001 7

1.37 12TH TSP

+18.60 F/L 29 64 05/94 RF0 Bobbin ODI 18 2.57 IST TSP

+2.71 F/L 05/94 RF0 H/L Special Int VOL 1.65 1ST TSP

+2.84 1ST TSP 29 67 05/94 RF0 Bobbin ODI 15 2.98 1ST TSP

+23.86 F/L i

05/94 RF0 Bobbin ODI 21 1.18 1ST TSP

+22.54 F/L 29 79 05/94 RF0 Bobbin ODI 38 0.65 10TH TSP

+42.16 F/L 05/94 RF0 C/L Special Int VOL 0.72 9TH TSP

-5.08 97H TSP 29 85 05/94 RF0 Bobbin NQI 0.62 4TH TSP

-9.30 F/L 05/94 RF0 H/L Special Int VOL 0.34 4TH TSP

-10.90 4TH TSP l

05/94 RF0 H/L Special Int VOL 1.31 4TH TSP

-9.57 4TH TSP 29 87 05/94 RF0 Bobbin 001 48 1.83 8TH TSP

-7.53 F/L 05/94 RF0 H/L Special Int VOL 0.93 8TH TSP

-6.68 8TH TSP 29 88 05/94 RF0 Bobbin 001 20 1.0811TH TSP

+1.61 F/L 05/94 RF0 C/L Special Int VOL 0.42 11TH TSP

+2.21 11TH TSP 29 89 05/94 RF0 Bobbin ADI 9.36 4AVB 10.20 F/L 05/94 RF0 U Bend VOL 1.15 4AVB

-9.72 4AVB 29 95 05/94 RF0 Boobin NCI 1.34 BTH TSP

+1.09 F/L 05/94 RF0 Bobbin 001 20 0.50 3RD TSP

+15.17' F/L

]

05/94 RFC Bobbin 001 13 1.79 13TH TSP

+29.26 F/L 05/94 RF0 H/L Special Int VOL 0.16 3RD TSP

-1.66 3RD TSP i

05/94 RF0 H/L Special Int VOL 0.17 3RD TSP

+15.17 3RD TSP

]

05/94 RF0 C/L Special Int VOL 0.45 12TH TSP

-12.65 12TH TSP 1

29 98 05/94 RF0 Bobbin 001 9

1.24 12TH TSP 8.18 F/L 29 100 05/94 RF0 Bobbin ADI 1.98 13TH TSP

+1.78 F/L 05/94 RF0 Bobbin ADI 2.29 13TH TSP

+2.81 F/L 05/94 RF0 Bobbin ADI 3.90 13TH TSP

+7.18 F/L 05/94 RF0 C/L Special Int VOL 0.38 13tH TSP

+2.18 13TH TSP 05/94 RF0 C/L Special Int VOL 0.50 13TH TSP

+1.38 13TH TSP 05/94 RF0 C/L Special Int VOL 0.66 13TH TSP

+6.50 13TH TSP 29 102 05/94 RF0 Bobbin NCI 0.41 97H TSP

-1.56 F/L 05/94 RF0 C/L Specist Int VOL 0.79 9TH TSP 1.58 91H TSP 29 105 05/94 RF0 Bobbin ODI 31 2.26 TTS-HL

+2.73 F/L I

i l

J

1 e***************************

BWNS TUBAN 11 (Version 2.0) 06/17/1994 06:22:10 ese.......ee......ee********

Catawba Nuclear Station - Unit Two

    • eeeeee********************

S/G B 05/94 RF0 Bcbbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U-Bend

      • ee.**********************

Page 12 of 21 S/G B - ATTACHMENT #2 INDICATIONS OF IMPERFECTIONS ROW COL OUTAGE TEST TYPE IND %TW VOLTS LOCATION EXTENT 1 05/94 RF0 H/L Special Int VOL 0.50 TTS-HL

+2.39 TTS HL 30 23 05/94 RF0 Bobbin 001 24 2.31 12TH TSP

+39.30 F/L 30 24 05/94 RF0 Bobbin 001 6

5.12 TTS-CL

+6.62 F/L 05/941?F0 Bobbin 001 21 3.67 18TH TSP

+1.97 F/L 05/94 RF0 Bobbin 001 34 1.70 10TH TSP

+42. 75 F/L 30 30 05/94 RF0 Bobbin 001 24 1.70 2ND TSP

+ 7. 03 F/L 30 31 05/94 RF0 Bobbin 001 34 1.95 8TH TSP

+6.08 F/L 30 33 05/94 RF0 Bobbin 001 19 1.41 12TH TSP

+22.17 F/L 05/94 RF0 C/L Special Int VOL 0.19 12TH TSP

+21.98 12TH TSP 30 34 05/94 RF0 Bobbin 001 21 0.95 14TH TSP

+11.82 F/L 30 41 05/94 RF0 Bobbin ADI 3.49 4AVB

-5.44 F/L 30 45 05/94 RF0 Bobbin ADI 8.68 3RD TSP

+20.10 F/L 05/94 RF0 H/L Special Int VOL 2.26 3RD TSP

+19.60 3RD TSP 30 51 05/94 RF0 Bobbin DDI 21 0.81 STH TSP

+9.74 F/L 30 52 05/94 RF0 Bobbin ADI 2.68 18TH TSP

+8.78 F/L 30 64 05/94 RF0 Bobbin ADI 4.08 TTS-CL

+2.16 F/L 05/94 RF0 Bobbin 001 12 1.03 2ND TSP

+7.25 F/L 05/94 RF0 Bobbin DDI 12 3.70 2ND TSP

+13.77 F/L 05/94 RF0 C/L Special Int VOL 0.50 TTS-CL

+2.41 TTS-CL 30 68 05/94 RF0 Bobbin ADI 4.42 2ND TSP

+17.96 F/L 05/94 RF0 H/L Special Int VOL 0.70 2ND TSP

+17.93 2ND TSP 30 70 05/94 RF0 Bobbin DDI 22 2.74 3AVB

-10.79 F/L 30 73 05/94 RF0 Bobbin 001 21 0.47 3AVB

-6.62 F/L 05/94 RF0 Bobbin ADI 7.17 10TH TF#

+5.68 F/L 05/94 RF0 Dobbin ADI 7.19 10TH ISP

+5.68 F/L 05/94 RF0 Bobbin N0!

0.81 12TH TSP

+10.52 F/L 05/94 RF0 Bobbin NQ!

1.25 12iH TSP

+15.24 F/L 05/94 RF0 Bobbin 001 26 1.98 4TH TSP

+19.96 F/L 05/94 RF0 C/L Special Int VOL 0.25 12TH TSP

+9.21 12TH TSP 05/94 RF0 C/L Special Int VOL 0.29 12TH TSP

+8.30 121H TSP 05/94 RF0 C/L Special Int VOL 0.38 12TH TSP

+5.80 12TH TSP 05/94 RF0 C/L Special Int VOL 0.39 12TH TSP

+6.34 12TH TSP 05/94 RF0 C/L Special Int VOL 0.46 12TH TSP

+10.31 12TH TSP 05/94 RF0 C/L Special Int VOL 0.50 12TH TSP

+9.23 12TH TSP 05/94 RF0 C/L Special Int VOL 0.72 12TH TSP

+14. 75 12TH TSP 05/94 RF0 C/L Special Int VOL 0.80 10TH TSP

+4.24 10TH TSP 30 89 05/94 RF0 Bobbin ADI 6.35 18TH TSP

+16.14 F/L 05/94 RF0 C/L Special Int VOL 0.4817TH TSP

-3.58 17TH TSP 05/94 RF0 C/L Special !nt VOL 1.4017TH TSP

-2.39 17TH TSP 30 90 05/94 RF0 Bobbin 001 77 1.87 4TH TSP

+18.79 F/L 05/94 RTO H/L Special Int VOL 1.39 4TH ISP

+18.79 4TH TSP 30 95 05/94 RF0 Bobbin ADI 4.96 3AVB

-17.11 F/L 05/94 RF0 Bobbin ADI 6.49 4AVB

-6.05 F/L 05/94 RF0 U-Dend VOL 0.72 3AVB

-13.43 3AVB 05/94 RF0 U Bend VOL 0.72 3AVB

-17.13 3AVB 05/94 RF0 U-Bend VOL 0.87 4AVB 6.48 4AVB 31 11 05/94 RF0 Bobbin WAR 15 0.53 4AVB

+0.00 F/L 31 10 05/94 RF0 Bobbin No!

0.50 17TH TSP

-0.49 F/L 05/94 RF0 Bobbin Nol 0.89 10TH TSP

+42.31 F/L 05/94 RF0 C/L Special Int VOL 1.47 17TH TSP

-0.24 17TH TSP 31 20 05/94 RF0 Bobbin 001 12 0.62 71H TSP

+21.76 F/L 05/94 RF0 Bobbin 001 13 1.28 77H.tP

+22.64 F/L 31 30 05/94 RF0 Bobbin 001 30 1.02 19TH TSP

+5.75 F/L 31 31 05/94 RF0 Schbin 001 20 1.62 11TH TSP

+i9.0C F/L 31 32 05/94 RF0 Bobbin 001 21 1.06 1cTH TSP

+6.48 F/L 1

31 33 05/94 RF0 Bobbin ODI 17 1.97 Sfh TSP

+2.09 r/L l

31 40 05/94 RF0 Bobbin 001 11 2.86 10TH ISP

+ 6.36 F/L 31 44 05/94 RF0 Bobbin 001 11 1.72 6TH TSP

+6.86 F/L 31 70 05/94 RF0 Bobbin NQI 1.21 1ST TSP

+7.31 F/L 05/94 RF0 N/L Special Int YOL 0.64 1ST TSP

+4.82 1ST TSP 05/94 RF0 N/L Special Int YOL 1.19 1ST TSP

+7.13 1ST TSP j

31 78 05/94 RF0 Bobbin NQI 1.98 7TH TSP

+12.45 F/L 05/94 RF0 H/L Special Int YOL 1.60 TTH TSP

+12.88 7TH TSP 31 94 05/94 RF0 Bobbin ADI 3.99 4AVB

+1.41 F/L 31 96 05/94 RF0 Bobbin DDI 38 0.67 STH TSP

+2.42 F/L 31 98 05/94 RF0 Bobbin N )!

0.72 814 TSP

+1.41 F/L l

BWNS TUBAN !! (Version 2.0) 06/17/1994 06:22:10 Catawba Nuclear Station - Unit Two e.........................**

gfg g 05/94 RF0 Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U-Bend Page 13 of 21 S/G B ATTACHMENT #2 INDICATIONS OF IMPERFECTIONS ROW COL DUTAGE TEST TYPE IND %TW VOLTS LOCATION EXTENT 1 31 101 05/94 RF0 Bobbin ADI 7.84 11TH TSP

+36.17 F/L 05/94 RF0 Bobbin NQI 0.70 18TH TSP

+5.50 F/L 05/94 RF0 C/L Special Int VOL 0.64 18TH TSP

+4.61 18TH TSP 05/94 RF0 C/L Special Int VOL 1.14 10TH TSP

-6.87 10TH TSP 05/94 RF0 C/L Special Int VOL 1.82 18TH TSP

+2.28 18TH TSP 32 14 05/94 RF0 Bobbin NQI 1.90 13TH TSP

+10.89 F/L 05/94 RF0 Bobbin 001 12 5.43 13TH TSP

+12.91 to +18.48 F/L 05/94 RF0 C/L Special Int VOL 1.30 13TH TSP

+10.48 13TH TSP 05/94 RF0 C/L Special Int VOL 0.50 13TH TSP

+12.93 to +15.53 13TH TSP 32 25 05/94 RF0 Bobbin 001 29 3.01 13TH TSP

+25.21 F/L 32 28 05/94 RF0 Bobbin 001 29 0.85 4TH TSP

+34.01 F/L 32 35 05/94 RF0 Bobbin 001 11 1.85 1AVB

+10.67 F/L 52 39 05/94 RF0 Bobbin 001 31 1.16 6TH TSP

+8.99 F/L 32 44 05/94 RF0 Bobbin 001 18 2.55 13fH TSP

+ 7. 89 F/L 32 45 05/94 RF0 Bobbin 001 19 1.99 17TH TSP

-1.15 F/L 05/94 RF0 C/L Special Int VOL 0.36 17TH TSP

-1.50 17TH TSP 32 53 05/94 RF0 Bobbin 001 25 2.54 7TH TSP

+13.65 F/L 05/94 RF0 H/L Special Int VOL 0.81 77H TSP

+14.14 7TH TSP 32 83 05/94 RF0 Bobbin ADI 4.84 11TH TSP

+33.35 F/L 05/94 RF0 C/L Special Int VOL 0.83 10TH TSP

-9.49 10TH TSP 32 90 05/94 RF0 Bobbin.

001 27 2.25 1STH TSP

+13.48 F/L 05/94 RF0 C/L Special Int VOL 0.66 18TH TSP

+9.24 187H TSP 05/94 RF0 C/L Special Int VOL C.9B iBTW ISP

+12.49 18TH TSP 32 93 05/94 RF0 Bobbin NQI 2.05 STH TSD

+24.85 F/L 05/94 RF0 H/L Special Int VOL 0.9t SYP.SP

+23.64 STH TSP 33 17 15/94 FF0 Bobbin NQI 1.59 71H TSP

+39.95 F/L "ev4 AFO H/L Special Int VOL 0.45 8TH TSP

-3.66 87H TSP v5/94 RF0 H/L Special Int VOL 0.58 8TH TSP 2.46 Bid TSP 05/94 RF0 H/L Special Int VOL 0.61 STH TSP

-1.14 8TH TSP 33 25 05/t4 RF0 Bobbin 001 34 2.09 16TH TSP

+2.25 F/L 33 42 05/94 RF0 Bobbin 001 17 2.25 TTS-HL

+1.91 F/L 05/94 RF0 Bobbin 001 10 2.06 13TH TSP

+25.22 F/L 05/94 RF0 H/L Special Int VOL 0.88 TTS HL

+2.46 TTS-HL 05/94 RF0 C/L Special Int VOL 0.50 12TH TSP

-18.00 12TH TSP 33 63 05/94 RF0 Bobbin A01 3.78 4AVB

-4.44 F/L 33 65 05/94 RF0 Bobbin 001 7

2.14 18TH TSP

+15.82 F/L 05/94 RF0 Bobbin 001 30 1.83 18TH TSP

+15.18 F/L 05/94 RF0 C/L Special Int VOL 1.34177H TSP

-2.86 177H TSP 05/94 RF0 C/L Special Int VOL 1.72 177H TSP

-2.33 177H TSP 33 68 05/94 RF0 Bobbin 001 54 1.51 BTH TSP

+1.63 F/L 33 71 05/04 RF0 Bobbin 001 22 2.41 8TH TSP

+1.31 F/L 33 72 05/94 RF0 Bobbin 001 14 2.46 BTH TSP

+1.60 F/L 33 73 05/94 RF0 Bobbin N01 0.44 BTH TSP

+1.70 F/L 33 74 05/94 RF0 Bobbin 001 44 1.27 8TH TSP

+1.52 F/L 33 75 05/94 RF0 Bobbin 001 4

1.81 BTH TSP

+1.67 F/L 33 76 05/94 RF0 Bobbin 001 2

1.41 8TH TSP

+1.93 F/L 33 78 05/94 RF0 Bobbin 001 47 0.97 8TH TSP

+1.41 F/L 33 79 05/94 RF0 Bobbin 001 17 1.69 71H TSP

+28.01 F/L 05/94 RF0 H/L Special Int VOL 0.66 7TH TSP

+28.66 7TH TSP 33 80 05/94 RF0 Bobbin Nol 1.11 13TH TSP

+25.68 F/L 05/94 RF0 C/L Special Int VOL 0.89 13TH TSP

+24.28 13fH TSP 33 86 05/94 RF0 Bobbin ADI S.87 STH T5P

+B.31 F/L 05/04 RF0 Bobbin NQI C.49 3RD TSP

+30.58 F/L 05/94 RF0 Bobbin NOI 0.71 11TH TSO

+13.27 F/L 05.94 RF0 H/L Special Int VOL 0.75 STH TSP

+8.87 STH TSP 05/94 RF0 H/L Special Int VOL 1.13 4TH ISP

-5.62 4TH TSP 05/94 RF0 C/L Special Int VOL 0.69 lith TSP

+12.99 11TH TSP 33 102 05/94 RFC Bobbin 001 2

1.38 3PO TSP

+33.67 F/L 34 18 05/94 RF0 Bobbin 001 26 1.79 9TH TSP

-0.96 F/L 34 23 05/94 RF0 Bobbin ADI 2.48 1AVB

+14.03 F/L 05/94 RF0 U-Bend VOL 0.38 1AVB

+12.42 2AVB 05/94 RF0 U Bend VOL 0.63 1AVB

+ 6.56 2AVB 34 35 05/94 RF0 Bobbin ADI 2.37 11TH TSP

+8.66 F/L 05/94 RF0 C/L Special int VOL 0.59 11TH TSP

+8.44 11TH TSP 34 43 05/94 RF0 Bobbin 001 27 0.60 7TH TSP

+37.89 F/L 34 62 05/94 RF0 Bobbin NQ1 2.42 10TH TSP

+25.55 i

F/L

BWNS TUBAN !! (Version 2.0) 06/17/1994 06:22:10 ee**************************

Catawba Nuclear Station - Unit Two S/G B 05/94 RF0 Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U Bend Page 14 of 21 S/G B ATTACHMENT #2 INDICATIONS OF IMPERFECTIONS ROW COL DUTAGE TEST TYPE IND %TW VOLTS LOCATION EXTENT 1 05/94 RF0 C/L Special Int VOL 2.72 10TH TSP

+22.94 10TH TSP 35 34 05/94 RFO Bobbin ODI 38 1.50 1ST TSP

+5.57 F/L 35 35 05/94 RFO Bobbin ADI 2.26 7TH TSP

+30.40 F/L 05/94 RF0 Bobbin DDI 28 1.10 77H TSP

+16.05 F/L 05/94 RF0 Bobbin 001 29 0.57 7TH TSP

+15.13 F/L 05/94 RF0 H/L Special Int VOL 2.41 BTH TSP

-12.36 8TH TSP 35 37 05/94 RFO Bobbin 001 14 1.11 12TH TSP

+34.75 F/L 35 38 05/94 RF0 Bobbin NOI 1.09 11TH TSP

+19.25 F/L 05/94 RF0 Bobbin DDI 10 0.73 11TH TSP

+22.99 F/L 05/94 RF0 C/L Special Int VOL 0.83 11TH TSP

+19.12 11TH TSP 35 42 05/94 RF0 Bobbin DDI 17 0.33 6TH TSP

+7.31 F/L 35 44 05/94 RF0 Bobbin 001 1

1.11 11TH 1SP

+12.45 F/L 35 47 05/94 RF0 Bobbin ADI 9.35 2AVB

+9.38 F/L 35 48 05/94 RF0 Bobbin NOI 0.51 151H TSP

+11.76 F/L 05/94 RF0 C/L Special Int VOL 0.51 14TH TSP

-6.29 14TH TSP 35 64 05/94 RF0 Bobbin NQI 0.84 11TH TSP

+13.92 F/L 05/94 RF0 C/L Special Int VOL 0.66 11TH TSP

+14.06 11TH TSP 35 66 05/94 RF0 Bobbin ADI 3.20 1ST TSP

+6. 73 F/L 05/94 RF0 Bobbin DDI 3

0.63 1ST TSP

+19.63 F/L 05/94 RF0 H/L Special Int VOL 0.64 1ST TSP

-5.60 IST TSP 05/94 RF0 H/L Special Int VOL 1.12 1ST TSP

'6.83 1ST TSP 35 91 05/94 RF0 Bobbin NQ1 0.44 18TH TSP

+1.21 F/L 05/94 RF0 C/L Special Int VOL 0.38 18TH TSP

+1.21 18TH TSP 35 93 05/94 RF0 Bo5 bin N01 0.78 12TH TSP

+37.49 F/L 05/94 RF0 C/L Special Int VOL 0.91 11TH TSP

-7.31 to

-0.63 11TH TSP 36 19 05/94 RF0 Bobbin ODI 18 0.97 BTH TSP

-1.27 F/L 36 26 05/94 RF0 Bobbin NOI 0.66 7TH TSP

+18.47 F/L 05/94 RF0 H/L Special Int VOL 0.85 7TH TSP

+18.91 TTH TSP 36 29 05/94 RF0 Bobbin ADI 4.48 STH TSP

+38.57 F/L 05/94 RF0 Bobbin NQ1 0.82 3RD TSP

-1.82 F/L 05/94 RF0 H/L Special Int VOL 0.69 6TH TSP

-3.45 6TH TSP 05/94 RF0 H/L Special Int VOL 1.25 3RD TSP

-2.15 3RD TSP 36 34 05/94 RF0 Bobbin ODI 7

1.02 6TH TSP

+36.35 F/L 05/94 RF0 H/L Special Int V9L 1.2) 7TH TSP

-6.48 7TH TSP 36 44 05/94 RF0 Bobbin NOI 0.53 12TH TSP

+6.97 F/L 05/94 RF0 C/L Special Int VOL 0.77 12TH TSP

+6.38 12TH TSP 36 63 05/94 RF0 Bobbin ADI 4.3719TH TSP

+ 7. 56 F/L 05/94 RF0 Bobbin NQI 0.62 19TH TSP

+3.94 F/L 05/94 RF0 C/L Special Int VOL 0.69 19TH TSP

+ 7. 56 19TH TSP 05/94 RF0 C/L Special Int VOL 1.28 197H TSP

+3.94 19TH TSP 36 79 05/94 RF0 Bobbin No!

0.51 71H TSP

+25.52 F/L 05/94 RF0 Bobbin NQI 1.12 STH TSP

+20.75 F/L 05/94 RF0 Bobbin 001 12 1.67 1ST TSP

+15.13 F/L 05/94 RF0 H/L Special Int VOL 0.57 7TH TSP

+26.01 7TH TSP 05/94 RF0 H/L Special Int VOL 1.25 5TH TSP

+21.17 STH TSP 36 82 05/94 RF0 Bobbin NO!

0.75 3RD TSP

+0.16 F/L 05/94 RF0 H/L Special Int VOL 1.04 3RD TSP

+0.16 3RD TSP 36 84 05/94 RF0 Bobbin NQ1 1.42 6TH TSP 430.11 F/L 05/94 RF0 H/L Special Int VOL 0.B8 6TH TSP

+28.44 6TH TSP 36 94 05/94 RF0 Bobbin NOI 0.b0 15fH TSP

+13.56 F/L 05/94 RF0 C/L Special Int VOL 0.73 14TH TSP

-5.20 to

+4.05 14TH TSP 37 16 05/94 RTO Robbin ODI 14 2.05 9TH TSP

+1.65 F/L 05/94 RF0 U Bend v0L 0.39 9TH TSP

+1.39 9TH TSF 37 18 05/94 RF0 Bobbin 001 11 1.94 91H TSP

+1.83 F/L 37 32 05/94 RF0 Bobbin NQ1 1.20 10TH TSP

+13.45 F/L 05/94 RF0 Bobbin 001 3

0.61 7TH TSP

+36.96 F/L 37 35 05/94 RF0 Bobbin NOI-0.38 10TH TSP

+35.25 F/L L

05/94 RFO Bobbin 001 42 0.69 10TH TSP

+42.36 F/L 37 36 05/94 RF0 Bobbin 001 15 0.41 14TH TSP

+15.62 F/L 37 40 05/94 RF0 Bobbin DDI 20 2.18 2ND TSP

+32.70 F/L 05/94 RF0 Bobbin DDI 22 1.77 STH TSP

+25.71 F/L 05/94 RF0 Bobbin 001 2

3.33 10TH TSP

+14.51 F/L 05/94 RF0 Bobbin 001 29 2.27 19TH TSP

+5.16 F/L 05/94 RF0 H/L Special Int VOL 0.87 6TH TSP

-17.59 6TH TSP 05/94 RF0 C/L Special Int VOL 0.69 19TH TSP

+5.02 19TH TSP 05/94 RF0 C/L Special Int VOL 1.1710TH TSP

+13.12 10TH TSP

e eeeeeeeeee****************

BWNS TUBAN II (version 2.0) 06/17/1994 06:22:10 eeeeeee*********************

Catawba Nuclear Station - Unit Two eeeeeeee....................

gfg g e***************************

05/94 RF0 Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U Bend Page 15 of 21 S/G B ATTACHMENT #2 INDICATIONS OF IMPERFECTIONS RDW COL DUTAGE TEST TYPE IND %TW VOLTS LOCATION EXTENT 1 37 64 05/94 RF0 Bcbbin 001 4

0.61 2ND TSP

+12.19 F/L 05/94 RF0 Bobbin ODI 7

0.78 2ND TSP

+17.65 F/L 37 47 05/94 RF0 Bobbin 001 2

1.94 17TH TSP

+ 7. 46 F/L 37 67 05/94 RF0 Bobbin 001 5

1.40 6TH TSP

+4.02 F/L 37 99 05/94 RF0 Bobbin WA' 17 0.93 4AVB

+0.00 F/L 38 16 05/94 RF0 Bobbin WAR 16 0.78 4AVB

+0.JO F/L 05/94 RF0 Bobbin WAR 17 0.85 2AVB

+0.00 F/L 05/94 RF0 U Bend VOL 0.23 2AVB

+0.00 97H TSP 05/94 RF0 U Bend VOL 0.25 4AVB

+0.00 9TH TSP 05/94 RF0 U Bend VOL 0.56 3AVB

+0.00 9TH TSP 05/94 RF0 U Bend VOL 1.04 97H TSP U.70 9TH TSP 38 18 05/94 RF0 Bobbin DDI 23 0.73 8TH TSP

-0.53 F/L 38 19 05/94 RF0 Bobbin 001 6

0.89 10TH T'P

+37.85 F/L 38 24 05/94 RF0 Bobbin 001 9

1.14 11TH TSP

+30.57 F/L 05/94 RF0 C/L Special Int VOL 0.19 10TH TSP

-15.38 10TH TSP 05/94 RF0 C/L Special Int VOL 0.55 10TH TSP

-11.42 10TH TSP 38 27 05/94 RF0 Bobbin ADI 2.29 13TH TSP

+5.15 F/L 05/94 RF0 Bobbin ADI 2.30 11TH TSP

+27.43 F/L 05/94 RF0 C/L Special Int VOL 0.36 10TH TSP

-15.51 10TH TSP 38 32 05/94 RF0 Bobbin ADI 6.03 177H TSP

+13.40 F/L 05/94 RF0 C/L Special Int VOL 0.56 177H TSP

+6.87 to +13.81 17TH TSP 38 36 05/94 RF0 Bobbin ADI 1.67 10TH TSP

+41.59 F/L 05/94 RF0 Bobbin 001 24 0.78 7TH TSP

+11.95 F/L 05/94 RF0 Bobbin 001 30 1.70 9tH TSP

-3.13 F/L 38 37 05/94 RF0 Bobbin NO!

0.24 TTH TSP

+13.22 F/L 05/94 RF0 Bobbin ADI 0.63 10TH TSP

-2.82 F/L 05/94 RFO H/L Special Int VOL 0 37 77H TSP

+14.58 77H TSP 38 45 05/94 RF0 Bobbin ADI 7.00 4AVB

-6.45 F/L 05/94 RF0 U 9end VOL 0.64 4AVB 4.81 9TH TSP 05/94 RF0 Bobbin 001 27 7.33 13TH TSP

+20.66 F/L 38 48 05/94 RF0 Bobbin 001 25 0.43 6TH TSP

+41.41 F/L 38 50 05/94 RF0 Bobbin ODI 30 2.99 TTS HL

+5.58 F/L 05/94 RF0 Bobbin ODI 29 4.00 1ST TSP

+1.27 F/L 05/94 RF0 H/L Special Int VOL 0.66 TTS HL

+6.01 1ST TSP 05/94 RF0 H/L Special Int VOL 1.06 1ST TSP

<1.89 1ST TSP 38 52 05/94 RF0 Bobbin 001 33 2.11 137H TSP

+6.31 F/L 38 54 05/94 RF0 Bobbin 001 35 1.62 4AVB

+7.00 F/L 05/94 RF0 Bobbin 001 24 1.51 IST TSP

+8.38 F/L 05/94 RF0 Bobbin 001 27 1.98 1ST TSP

+17.82 F/L 05/94 RF0 Bobbin 001 32 1.771ST TSP

+19.33 F/L 05/94 RF0 Dobbin 001 7

2.60 17TH TSP

+13.49 F/L 38 59 05/94 RF0 Bobbin ODI 2

1,81 9TH TSP

+9.85 F/L 38 62 05/94 RF0 Bobbin ODI 9

2.31 STH TSP

-1.66 F/L 05/94 RF0 H/L Special Int VOL 1.66 8TH TSP

-0.80 STH TSP 38 65 05/94 RF0 Bobbin 001 6

3.86 187H TSP

+12.80 F/L 38 66 05/94 RF0 Bobbin 001 16 0.34 9TH TSP

-0.74 F/L 38 69 05/94 RF0 Bobbin NQI 1.07 11TH TSP

+29.36 F/L 05/94 RF0 C/L Special Int VOL 1.6010TH TSP 13.53 10TH TSP 38 75 05/94 RF0 Bobbin No!

0.63 14TH TSP

+8.32 F/L 05/94 RF0 Bobbin NQ!

1.21 17TH TSP

+13.41 F/L 05/94 RF0 C/L Speclat Irt VOL 0.84 16TH TSP

-4.81 16TH TSP 05/94 RF0 C/L Special Int VOL 1.28 14TH TSP

+5.30 to +10.10 14TH TSP 38 76 05/94 RF0 Bobbin Nol 1.27 4TH TS?

+27.97 F/L 05/94 AF0 H/L Specist Int VOL 0.72 SiH TSP

-13.S6 STP ?SP 38 80 05/94 RF0 Bobbin WAR 21 1.22 1AVB

+0.00 t/L 05/94 kFO Bobbin WAR 23 1.41 2AVB

+0.00 F/L 05/94 RF0 Bobbin WAR 32 2.41 3AVB

+0.00 F/L 05/94 RF0 Bobbin 001 18 1.77 71H TSP

+34.98 F/L 38 82 05/94 RF0 Bobbin WAR 12 0.63 2AVB

+0.00 F/L 05/94 RF0 Bobbin WAR 37 3.40 3AVB

+0.00 F/L 05/94 RF0 Bobbin No!

0.66 2ND TSP

+31.49 F/L 05/94 RF0 Bobbin 001 16 2.24 3RD TSP

+23.87 F/L 05/94 RF0 U Bend VOL 1.02 3AVB

+0.00 8TH TSP 05/94 RF0 U-Bend VOL 1.67 3AVB

+13.02 BTH TSP 05/94 RF0 N/L Special Int VOL 0.61 3RD TSP

-6.18 3RD TSP 05/94 RF0 H/L $pecial Int VOL 0.95 3RD TSP

-4.42 3RD TSP

1 I

eeeeeeeee*******************

BWNS TUBAN II (Version 2.0) 06/17/1994 06:22:10 eeeeeee*********************

Catawba Nuclear Station - Unit Two S/G B eeeeeeee+***..**************

05/94 RF0 Bobbin.C/L Spec'al Interest,H/L Special Interest,H/L Tubesheet,U-Bend l

Page 16 of 21 S/G B - ATTACHMENT #2 INDICATIONS OF IMPERFECTIONS ROW COL DUTAGE TEST TYPE IND %TW VOLTS LOCATION EXTENT 1 38 83 05/94 RF0 Bobbin ADI 1.69 3RD TSP

+5.02 F/L 05/94 RF0 H/L Special Int VOL 0.94 3RD TSP

+5.36 3RD TSP 38 85 05/94 RF0 Bobbin NQI 0.50 2ND TSP

+11.55 F/L 05/94 RF0 Bobbin 001 22 1.73 TTS HL

+5.57 F/L 05/94 RF0 Bobbin 001 23 0.62 2ND TSP

+10.42 F/L 05/94 RF0 H/L Special Int VOL 0.36 2ND TSP

+11.45 2ND TSP 05/94 RF0 H/L Special Int VOL 0.38 2ND TSP

+10.35 2ND TSP 38 86 05/94 RF0 Bobbin No!

1.17 3RD TSP

+7.30 F/L 05/94 RF0 Bobbin ADI 4.16 14TH TSP

+13.95 F/L 05/94 RF0 H/L Special Int VOL 0.53 3RD TSP

+7.60 3RD TSP 05/94 RF0 C/L Special Int VOL 0.59 13TH TSP

-3.23 13fH TSP 38 92 05/94 RF0 Bobbin 001 3

2.04 4TH TSP

+30.29 F/L 38 97 05/94 RF0 Bobbin 001 16 1.96 7TH TSP

+33.77 F/L 39 17 05/94 RF0 Bobbin 001 25 0.86 6TH TSP

+39.41 F/L 39 18 05/94 RF0 Bobbin ADI 5.03 14TH TSP

+2.46 F/L 05/94 RF0 C/L Special int VOL 0.39 14TH TSP

+4.59 14TH TSP 05/94 RF0 C/L Special Int VOL 0.78 14TH TSP

+2.07 14TH TSP 39 22 05/94 RF0 Bobbin 001 31 0.67 STH TSP

+19.07 F/L 39 23 05/94 RF0 Bobbin 001 35 1.65 4TH TSP

+34.80 F/L 05/94 RF0 H/L Special Int VOL 1.44 STH TSP

-8.26 STH TSP 39 29 05/94 RF0 Bobbin 001 35 1.40 1ST TSP

+20.42 F/L 05/94 RF0 Bobbin 001 25 1.19 16TH TSP

+6.05 F/L 05/94 RF0 H/L Special Int VOL 0.72 2ND TSP

-7.85 2ND TSP 39 34 05/94 RF0 Bobbin 001 25 1.32 3RD TSP

+24.25 F/L 05/94 RF0 Bobbin 001 32 1.22 3RD TSP

+30.68 F/L 39 35 05/94 RF0 Bobbin 001 32 0.67 97H TSP

-1.82 F/L 39 39 05/94 RF0 Bobbin ADI 0.64 7TH TSP

+22.75 F/L 05/94 RF0 H/L Special Int VOL 0.81 7TH TSP

+23.15 77H TSP 39 46 05/94 RF0 Bobbin 001 24 2.49 1AVB

+13.58 F/L 05/94 RF0 Bobbin 001 12 1.74 2ND TSP

+8.01 F/L 05/04 RF0 Bobbin 001 15 1.96 6TH TSP

+31.45 F/L 05/94 RF0 Bobbin 001 15 2.55 3RD TSP

+15.31 F/L 05/94 RF0 Bobbin 001 34 2.26 10TH TSP

+9.21 F/L 39 47 05/94 RF0 Bobbin 001 7

0.76 7TH TSP

+20.06 F/L 39 55 C5/94 RF0 Bobbin 001 33

1. 64 1 AVB

+24.68 F/L 05/94 RF0 Bobbin 001 10 2.7313TH TSP

+7.97 F/L 05/94 RF0 Bobbin 001 24 4.89 16TH TSP

+3.03 F/L 39 67 05/94 RF0 Bobbin ADI 2.68 TTS-ML

+3.85 F/L 05/94 RF0 H/L Spe:ial Int VOL 0.37 TTS HL

+3.65 TTS-nt 05/94 RF0 H/L Spe:ial Int VOL 0.64 TTS HL

+5.22 TTS HL 39 70 05/94 RFC Bobbin 001 36 1.09 BTH TSP

+2.34 F/L 39 72 05/94 RF0 Bobbin ADI 4.28 TTS-CL

+3.58 F/L 05/94 RF0 Bobbin ADI 3.48 15TH TSP

+5.80 F/L 05/94 RF0 C/L Special Int VOL 0.14 TTS-CL

+ 2.43 TTS CL 05/94 RF0 C/L Special Int VOL 0.38 15TH TSP

+6.02 15TH TSP 39 75 05/94 RF0 Bobbin NOI 1.15 BTH TSP

+2,20 F/L 39 85 05/94 RF0 Bobbin NQ1 0.37 17TH TSP

+9.54 F/L 05/94 RF0 Bobbin 001 4

1.08 10TH TSP

+33.08 F/L 05/94 RF0 Bobbin 001 34 0.48 11TH TSP + 27. 75 F/L 39 89 05/94 RF0 Bobbin NO!

0.64 14TH TSP

+2.47 F/L 39 91 05/94 RF0 Bobbin 001 2

0.84 16TH TSP

+15.56 F/L 39 92 05/94 RF0 Bobbin 001 15 1.25 1ST TSP

+9.14 F/L 39 93 05/94 RF0 Bobbin ADI 3.59 3AVB

-14.07 F/L 39 95 05/94 RF0 Cobbin ADI 1.68 2ND TSP 12.80 F/L i

05/94 RF0 H/L Special Int VOL 0.25 2ND TSP

+2.94 2ND TSP 39 97 05/94 RF0 Bobbin 001 5

3.29 14TH TSP

+14.14 F/L 40 18 05/94 RTO Bobbin NQ1 0.70 TTS HL

+1.73 F/L 40 24 05/94 RF0 Bobbin 001 6

0.56 13TH TSP

+1.99 F/L 40 25 05/94 RF0 Bebbin DDI 21 2.39 4AVB

+4.21 F/L i

40 29 05/94 RF0 Bobbin 001 2

0.71 6TH TSP

+21.60 F/L l

40 33 05/94 RF0 Bobbin NQI 0.70 11TH TSP

+3.56 F/L 05/94 RF0 C/L Special Int VOL 0.83 11TH TSP

+3.31 11TH TSP 40 35 05/94 RF0 Bobbin ODI 9

1.30 BTH TSP

+23.46 F/L 40 37 05/94 RF0 Bobbin 001 12 0.96 13TH TSP

+8.52 F/L 40 39 05/94 RF0 Bobbin 001 21 0.91 11TH TSP

+8.88 F/L 40 42 05/94 RF0 Bobbin 001 21 1.49 19TH TSP

+6.50 F/L

eeeeeeee********************

BWNS TUBAN II (Version 2.0) 06/17/1994 06:22:10 eee*************************

Catawba Nuclear Station - Unit Two eeeeeeee..******************

S/G B 1

05/94 RF0 Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U Bend Page 17 of 21 S/G B - ATTACHMENT #2 INDICATIONS OF IMPERFECTIONS RDW COL OUTAGE TEST TYPE IND %TW VOLTS LOCATION EXTENT 1 40 43 05/94 RF0 Bobbin 001 6

1.13 10TH TSP

+6.97 F/L 40 46 05/94 RF0 Bobbin ADI 4.17 3RD TSP

+2.43 F/L 05/94 RF0 Bobbin 001 18 0.40 11TH TSP

+13.97 F/L 05/94 RF0 Bobbin 001 21 0.41 12TH TSP

+37.2F F/L 40 48 05/94 RF0 Bobbin 001 16 0.54 13TH TSP

+3.52 F/L 40 50 05/94 RF0 Bobbin 001 3

0.64 8TH TSP

-1.21 F/L 05/94 RF0 Bobbin 001 33 0.29 7TH TSP

+7.20 F/L 05/94 RFC H/L Special Int VOL 0.59 81H TSP

-0.67 BTH TSP 05/94 RF0 H/L Special Int VOL 0.84 8TH TSP

-1.28 8TH TSP 40 51 05/94 RF0 Bobbin ODI 11 1.26 STH TSP

+25.17 F/L 40 59 05/94 RF0 Bobbin NQI 1.55 4AVB

-3.60 F/L 05/94 RF0 U Bend VOL 0.59 4AVB

-3.06 4AVB 40 60 05/94 RF0 Bobbin ODI 5

0.77 2ND TSP

+11.02 F/L 05/94 RF0 H/L Special Int VOL 1.28 2ND TSP

+11.02 2ND TSP 40 64 05/94 RF0 Bobbin 00!

37 1.51 1ST TSP

+0.50 F/L 05/94 RF0 H/L Special Int VOL 0.33 1ST TSP

+0.51 1ST TSP 05/94 RF0 H/L Special Int VOL 0.43 IST TSP

+0.56 1ST TSP 05/94 RF0 H/L Special Int VOL 0.55 1ST TSP

+0.55 1ST TSP 05/94 RF0 H/L Special Int VOL 0.56 1ST TSP

+0.50 1ST TSP 40 74 05/94 RFC Bobbin 001 28 1.30 1ST TSP

+11.37 F/L 40 80 05/94 RF0 Bobbin ADI 1.88 11TH TSP

+28.27 F/L 40 88 05/94 RF0 Bobbin ADI 3.09 1AVB

+12.20 F/L 05/94 RF0 U-Bend VOL 1.05 1AVB

+11.74 8TH TSP 40 89 05/94 RF0 Bobbin ODI 1

1.21 9TH TSP

+1.72 F/L 41 25 05/94 RF0 Bobbin ODI 14 1.18 13TH TSP

+2.50 F/L 05/94 RF0 C/L Special Int VOL 0.53 13TH TSP

+2.02 13fH TSP 41 33 05/94 RF0 Bobbin No!

0.88 13TH TSP

+3.50 F/L 41 50 05/94 RF0 Bobbin DDI 13 2.24 TTS-CL

+5.78 F/L 05/94 RF0 Bobbin 001 39 0.81 13fH TSP

+16.35 F/L 05/94 RF0 C/L Special Int VOL 0.89 13TH TSP

+15.45 13TH TSP 41 53 05/94 RF0 Bobbin 001 8

2.76 1ST TSP

+18.27 F/L 41 60 05/94 RF0 Bobbin N01 0.76 2ND TSP

+24.67 F/L 05/94 RF0 Bobbin 001 8

0.84 7TH TSP

+20.18 F/L 05/94 RF0 H/L Special Int VOL 0.34 2ND TSP

+30.75 2ND TSP 41 64 05/94 RF0 Bobbin DDI 44 2.26 1ST TSP

+0.49 F/L 05/94 RF0 H/L Special Int VOL 0.78 1ST TSP

+0.57 1ST TSP 05/94 RF0 H/L Special Int VOL 0.85 iST TSP

+0.51 1ST TSP 05/94 RF0 H/L Special Int VOL 0.86 1ST TSP

+0.49 1ST TSP 05/94 RF0 H/L Special Int VOL 0.91 1ST TSP

+0.49 iST TSP 41 68 05/94 RF0 Bobbin ADI 4.99 11TH ISP

+31.37 F/L.

41 71 05/94 RF0 Bobbin 001 7

0.84 12TH TSP

+39.28 F/L 41 72 05/94 RF0 Bobbin ADI 4.87 2AVB

+23.85 F/L 05/94 RF0 U-Bend VOL 1.58 2AVB

+17.68 2AVB 41 76 05/94 RF0 Bobbin NQI 0.84 10TH TSP

+31.44 F/L 05/94 RF0 Bobbin No!

0.88 10TH TSP

+30.06 F/L 05/94 RF0 C/L Special Int VOL 1.04 9TH TSP

-12.30 9TH TSP 05/94 RF0 C/L Special Int VOL 1.18 9TH TSP

-13.48 9TH TSP 41 78 05/94 RF0 Bobbin 001 19 1.81 TTS-CL

+2.10 F/L 05/94 RF0 Bobbin ADI 3.40 13TH TSP

+20.25 F/L 41 80 05/94 RF0 Bobbin 001 26 3.31 15fH TSP

+5.97 F/L 41 91 05/94 RF0 Bobbin ADI 1.26 7TH TSP

+32.41 F/L 05/94 RF0 Bobbin 001 2

1.02 7TH TSP

+31.53 f/L 05/94 RF0 h/L Speciel ir.t VGL 1.06 7TH TSP

+32.47 713 TSP 41 92 05/94 2FO Bobbin NCI 1.13 4AVB

-15.57 F/L 05/94 R50 U-Bend VUL 0.67 4AVB

-15.07 4AVB 42 21 05/94 RF0 Bobbin NQt 3.19 TTS ML

+1.31 F/l.

05/94 RF0 Bobbin 001 34 0.33 10TH TSP

+2.09 F/L 42 22 05/94 RF0 C/L Special Int V0L l.41 18TH TSP

+0.00 18TH TSP 42 23 05/94 RF0 Bobbin 001 26 1.53 16TH TSP

+8.36 F/L 42 24 05/94 RFO Bobbin ADI 4.82 2AVB

+6.84 F/L 42 25 05/94 RF0 Bobbin 001 38 0.37 8TH TSP

-0.61 F/L 42 30 05/94 RF0 Bobbin 001 7

0.92 2ND TSP

+21.37 F/L 05/94 RF0 H/L Special Int VOL 1.20 3RD TSP

-14.66 3RD TSP 42 34 05/94 RFO Bobbin ADI 5.51 4AVD

+21.44 F/L 42 36 05/94 RF0 Bobbin 001 21 0.99 15TH TSP

+6.14 F/L 42 41 05/94 RF0 Bobbin 001 2

1.171ST TSP

+19.16 F/L

l BWNS TUBAN !! (V.rsion 2.0) 06/17/1994 06:22:10 Catawba Nuclear Station - Unit Two e............**.............

Sfg g 05/94 RF0 Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U Bend i

Page 18 of 21 S/G B - ATTACHMENT #2 INDICATIONS OF !MPERFECTIONS RDW COL OUTAGE TEST TYPE IND %TW VOLTS LOCATION EXTENT 1 42 45 05/94 RF0 Bobbin NQI 0.75 18TH TSP

+0.85 F/L 05/94 RF0 C/L Special Int VOL 1.33 18TH TSP

+0.56 18TH TSP I

42 59 05/94 RFC Bobbin 001 12 2.95 12TH TSP

+40.28 F/L 05/94 RF0 C/L Special Int VOL 0.83 11TH TSP

-3.02 11TH TSP 42 60 05/94 RF0 Bobbin 001 6

1.53 16TH TSP

+9 44 F/L 05/94 RF0 Bobbin 001 14 0.88 15TH TSP

+10.12 F/L 42 61 05/94 RF0 Bobbin NQI 0.94 3RD TSP

+15.84 F/L 05/94 RF0 H/L Special Int VOL 0.93 3RD TSP

+16.22 3RD TSP 42 68 05/94 RF0 Bobbin 001 2

2.17 STH TSP

+ 31. 64 F/L 42 86 05/94 RF0 Bobbin NQI 0.49 13TH TSP

-0.05 F/L 05/94 RF0 C/L Special Int VOL 2.29 13TH TSP

+C.06 13fH TSP l

42 92 05/94 RF0 Bobbin ADI 2.56 12TH TSP

+18.84 F/L 05/94 RF0 C/L Special Int VOL 0.48 12TH TSP

+15.71 12TH TSP 42 94 05/94 RF0 Bobbin ADI 2.66 11TH TSP

+30.42 F/L 05/94 RF0 C/L Special Int VOL 0.73 10TH TSP

-11.46 10TH TSP 43 22 05/94 RFC Bobbin NQI 2.31 TTS HL

+1.33 F/L 05/94 RF0 Bobbin 001 7

0.21 19TH TSP

+4.47 F/L 05/94 RF0 H/L Tubesheet VOL 0.62 TTS HL

+1.57 TTS HL 05/94 RF0 H/L Special Int VOL 0.56 Tis HL

+1.26 1ST TSP 43 23 05/94 RF0 Bobbin ADI 1.86 10TH TSP

+40.06 F/L 05/94 RF0 C/L Special Int VOL 0.74 9TH TSP

-2.06 9TH TSP 43 26 05/94 RF0 Bobbin NQI 0.50 13TH TSP

+2.16 F/L 05/94 RF0 C/L Special Int VOL 0.94 13TH TSP

+2.18 13TH TSP 43 28 05/94 RF0 Bobbin ADI 5.73 4AVB

+5.37 F/L 05/94 RF0 U-Bend VOL 1.41 4AVB

+4.62 9TH TSP 05/94 RF0 U-Bend VOL 0.36 9TH TSP

-1.61 9TH TSP 43 32 05/94 RF0 Bobbin 001 3

0.66 7TH TSP

+29.12 F/i 43 34 05/94 RF0 Bobbin 001 8

0.67 7TH TSP

+6.00 F/l 43 35 05/94 RF0 Bobbin No!

0.34 9TH TSP

-0.84 F/L 05/94 RFC Bobbin NQI 1.34 7TH TSP

+12.90 F/L 43 38 05/94 RF0 Bobbin NQI 0.58 16TH TSP

+1.07 F/L 05/94 RF0 C/L Special Int VOL 0.41 16TH TSP

-2.35 to

+4.69 16TH TSP 43 39 05/94 RF0 Bobbin NCI 0.61 18TH TSP

+15.17 F/L 05/94 RFo Bobbin NQI 0.70 171H TSP

-1.68 F/L 05/94 RF0 Bobbin NCI 0.76 18TH TSP

+15.83 F/L 05/94 RF0 C/L Special Int VOL 0.41 18TH TSP

+14.91 18TH TSP 05/94 RF0 C/L Special Int VOL 0.49 18TH TSP

+16.05 18TH TSP 43 41 05/94 RF0 Bobbin NQI 0.41 8TH TSP

-2.67 F/L 05/94 RF0 Bobbin NQI 1.35 STH TSP

+26.79 F/L 05/94 RF0 H/L Special Int VOL 1.38 STH TSP

+27.29 STH TSP 43 47 05/94 RF0 Bobbin NOI 2.87 3AVB

+2.97 F/L 05/94 RF0 Bobbin NQI 1.46 12TH TSP

+15.65 F/L 05/94 RF0 C/L Special Int VOL 1.53 12TH TSP

+14.91 12TH TSP 43 49 05/94 RF0 Bobbin NQ!

1.56 97H TSP

-0.08 F/L 43 50 05/94 Rf0 Bobbin 001 7

3.31 13TH TSP

+33.08 F/L 43 66 05/94 RF0 Bobbin 001 10 3.13 14TH TSP

+4.61 F/L 43 67 05/94 RF0 Bobbin ADI 2.59 12TH TSP

+40.69 F/L 05/94 RF0 Bobbin ADI 4.32 11TH TSP

+16.84 F/L 05/94 RF0 C/L Special Int VOL 0.38 11TH TSP

-2.28 11TH TSP 05/94 RF0 C/L Special Int VOL 0.57 11TH TSP

+14.46 11TH TSP 43 86 05/94 RF0 Bobbin ADI 3.82 13TH TSP

+31.32 F/L 43 88 05/94 RF0 Bobbin 001 21

?.13 3RD ISP

+20.25

'i; 43 90 05/94 RF0 Bobbin NQI U.52 14TH TSP

+9.20 F /I.

05/94 RF0 C/L Special Int VOL 0.05 14TH ISP

+4.81 14TH TSP 05/94 RF0 C/L Special Int VOL 0.63 14TH TSP

+0.85 14fH TSP 05/94 RF0 C/L Special Int VOL 0.84 14TH TSP

+2.68 14TH TSP 05/94 RF0 C/L Special int VOL 0.34 14TH TSP

  • 8.08 14TH T5P 43 93 05/94 RF0 Bobbin ADI 4.22 TTS-HL

+3.76 F/L 05/94 RF0 H/L Special Int VOL 0.32 TTS HL

+3.85 TTS HL 44 23 05/94 RF0 Bobbin NCI 5.56 TTS-HL

+1.37 F/L 05/94 RF0 H/L Special Int VOL 1,57 TTS HL

+1.37 1ST TSP 44 26 05/94 RF0 Bobbin 001 3

0.63 10TH TSP

+8.55 F/L 44 33 05/94 RF0 Bobbin 001 10 1.76 17TH TSP

+7.47 F/L 44 35 05/94 RF0 Bobbin 001 12 1.26 9TH TSP

-0.79 F/L 44 36 05/94 RF0 bobbin ODI 34 0.47 7TH TSP

+6.29 F/L 44 39 05/94 RF0 Bobbin 001 24 1,43 13TH TSP

+10.78 F/L

BWNS TUBAN 11 (Version 2.0) 06/17/1994 06:22:10

                • e,******************

Catawba Nuclear Station - Unit Two S/G B 05/94 RF0 Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U-Bend

                    • ....*........u..*

Page 19 of 21 S/G B - ATTACHMENT #2 INDICATIONS OF IMPERFECTIONS ROW COL OUTAGE TEST TYPE IND %TW VOLTS LOCATION EXTENT 1 44 48 05/94 RF0 Bobbin ODI 17 0.69 14TH TSP

+6.49 F/L 05/94 RF0 Bobbin 001 17 1.43 12TH TSP

+11.05 F/L 44 49 05/94 RF0 Bobbin 001 21 2.66 10TH TSP

-3.64 F/L 44 50 05/94 RF0 Bobbin ADI 2.04 7TH TSP

+38.06 F/L 05/94 RF0 Bobbin Nol 1.07 2ND TSP

+3.85 F/L 05/94 RF0 h/L Special Int VOL 0.92 2ND TSP

+3.74 2ND TSP 44 54 05/94 RF0 Bobbin ODI 19 1.09 10TH TSP

+6.96 F/L 05/94 RF0 Bobbin ODI 25 1.51 10TH TSP

+23.65 F/L 44 56 05/94 RF0 Bobbin ODI 13 2.96 11TH TSP

+31.15 F/L 44 72 05/94 RF0 Bobbin ADI 2.28 14TH TSP

+1,95 F/L 05/94 RF0 C/L Special Int VOL 0.39 14TH TSP

+1.72 14TH TSP 44 84 05/94 RFO Bobbin ADI 0.90 3RD TSP

+11.71 F/L 05/94 RF0 Bobbin ADI 2.55 10TH TSP

+23.43 F/L 05/94 RF0 H/L Special Int VOL 0.52 3RD TSP

+11.89 3RD TSP 05/94 RF0 H/L Special Int VOL 0.82 3RD TSP

+10.95 3RD TSP 05/94 RF0 C/L Special Int VOL 0.19 10TH TSP

+18.09 10TH TSP 44 88 05/94 RFC Bobbin ODI 9

0.57 4TH TSP

+38.82 F/L 44 91 05/94 RF0 Bobbin WAR 13 0.68 2AVB

+0.00 F/L 05/94 RF0 Bobbin 001 2

0.95 7TH TSP

+27.68 F/L 05/94 RF0 Bobbin 001 16 0.40 7TH TSP

+27.15 F/L 45 24 05/94 RF0 Bobbin Nc!

3.04 TTS-HL

+1.25 F/L 05/94 RF0 H/L Special Int VOL 0.50 TTS-HL

+1.28 1ST TSP 45 37 05/94 RF0 Bobbin 001 42 0.83 19TH TSP

+0.43 F/L 05/94 RF0 C/L Special Int VOL 0.45 19TH TSP

+0.40 19TH TSP 45 39 05/94 RF0 Bobbin NDI 0.81 2AVB

+31.64 F/L 05/94 RF0 U-Bend VOL 1,56 2AVB

+28.23 2AVB 45 41 05/94 RF0 Bobbin NCI 0.64 9TH (SP

-3.05 F/L 45 42 05/94 RF0 Bobbin NQI 0.37 7TH Tk9

+39.04 F/L 45 47 05/94 RF0 Bobbin No!

0.49 15fH TS7

+21.37 F/L 05/94 RF0 Bobbin 001 10 2.01 151H TSP

-7.94 F/L 05/94 RF0 Bobbin 001 23 3.09 13TH TSP

+10.71 F/L 05/94 RF0 H/L Tubesheet VOL 0.75 TTS-HL 0.07 TTS ML k

45 60 05/94 RF0 Bobbin ODI 23 0.71 4TH TSP

+24.39 F/L

)

05/94 RF0 Bobbin 001 16 1.17 18TH TSP

+7.26 F/L 45 61 05/94 RF0 Bobbin ODI 16 1.96 2ND TSP

+1.42 F/L 45 64 05/94 RF0 Bobbin 001 30 1.34 4AVB

+6.00 F/L 05/94 RF0 Bobbin ADI 1.26 7TH TSP

+37.21 F/L 05/94 RF0 Bobbin Nol 1.70 BTH TSP

-1.03 F/L 05/94 RF0 Bobbin NCI 1.90 9TH TSP

-0.71 F/L 45 68 05/94 RFO Bobbin ODI 28 0.79 6TH TSP

+31.94 F/L 45 T3 05/94 RF0 Bobbin ADI 1.15 11TH TSP

+19.35 F/L 45 77 05/94 RfD Bobbin ADI 3.45 4TH TSP

+5.72 F/L 05/94 RF0 Fiobbin 001 2

1.61 16TH TSP

+ 0.27 F/L 05/94 RF0 H/L Specist Int VOL 0.37 4TH TSP

+ 7.13 4TH TSP 05/94 RF0 C/L Special Int VOL 0.91 177H TSP

+17.81 17TH TSP 45 80 05/94 RF0 Bobbin ADI 6.89 12TH TSP

+2.61 F/L 45 81 05/94 RF0 Bobbin 001 9

1.00 2ND TSP

+24.69 F/L 05/94 RF0 Bobbin ODI 22 1.75 2ND TSP

+29.89 F/L 05/94 RF0 H/L Special Int VOL 0.74 3RD TSP 12.00 3RD TSP l

05/94 RF0 H/L Special Int VOL 1.42 3RD TSP

-7.00 3RD TSP l

45 85 05/94 RF0 Bobbin ODI 13 0.8910TH TSP

+26.43 F/L 46 34 05/94 RFC Bobbin ODI 30 2.93 12TH TSP

+9.57 F/L 46 39 05/94 RF0 Bobbin 001 29 0.86 10TH TSP

+37.21 F/L 46 41 05/94 RF0 Bobbin 001 17 0.89 7TH TSP

+40.54 F/L 05/94 RF0 H/L Special Int VOL 1.28 BTH TSP

-1.77 BTH TSP 46 60 05/94 RF0 Bobbin 001 5

0.40 17TH TSP

+14.47 F/L 05/94 RF0 Bobbin 001 18 0.65 17TH TSP

+26.67 F/L 05/94 RTO Bobbin 001 26 0.40 171H TSP

+6.26 F/L 46 71 05/94 RF0 Bobbin ADI 5.01 13TH TSP

+3.09 F/L i

46 77 05/94 RF0 Bobbin NQI 2.06 157H TSP

+19.75 F/L j

05/94 RF0 C/L Special Int VOL 1.74 15TH TSP

+18.93 15TH TSP l

46 79 05/94 RF0 Bobbin 001 5

1.94 12TH TSP

+26.19 F/L 05/94 RF0 Bobbin 001 13 0.53 11TH TSP

+1.3C F/L 05/94 RF0 Bobbin 001 33 0.58 17TH TSP

+28.50 F/L 05/94 RF0 C/L Special Int VOL 0.52 11TH TSP

+1.32 11TH TSP 05/94 RF0 C/L Special Int VOL 0.57 11TH TSP 2.42 11TH TSP

BWNS TUBAN 11 (version 2.0) 06/17/1994 06:22:10 e***************************

Catawba Nuclear Station - Unit Two

.........+++****************

S/G B 05/94 RF0 Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U Bend Page 20 of 21 S/G B - ATTACHMENT #2 INDICATIONS OF IMPERFECTIONS ROW COL DUTAGE TEST TYPE IND %TW VOLTS LOCATION EXTENT 1 46 82 05/94 RF0 Bobbin 001 12 2.11 17TH TSP

+15.59 F/L 05/94 RF0 Bobbin 001 14 1.04 12TH TSP

  • 39.37 F/L 47 27 05/94 RF0 Bobbin WAR 12 0.51 4AVB

+0.00 F/L 05/94 RF0 Bobbin WAR 19 0.90 3AVB

+0.00 F/L 47 28 05/94 RF0 Bobbin WAR 12 0.50 4AVB

+0.00 F/L 47 29 05/94 RFO Bobbin No!

0.42 13TH TSP

+30.30 F/L 05/94 RF0 C/L Special Int VOL 1.23 12TH TSP

-12.42 12TH TSP 47 32 05/94 RF0 Bobbin No!

0.3715TH TSP

+15.85 F/L 47 38 05/94 RF0 Bobbin 001 38 1.08 9TH TSP

-1.40 F/L 47 62 05/94 RF0 Bobbin NO!

2.44 4AVB

+3.34 F/L 05/94 RF0 Bobbin NQI 2.82 3AVB

+6.62 F/L 05/94 RF0 U Bend VOL 0.65 4AVB

+4.13 4AVB 05/94 RF0 U Bend VOL 0.66 3AVB

+6.68 3AVB 05/94 RF0 Bobbin No!

4.02 3RD TSP

+ 30. 72 F/L 05/94 RF0 H/L Special Int VOL 0.65 4TH TSP

-8.40 4TH TSP 05/94 RF0 H/L Special Int VOL 0.96 4TH TSP

-8.96 4TH TSP 05/94 RF0 H/L Special Int VOL 1.61 4TH TSP

-9.27 4TH TSP 47 69 05/94 RF0 Bobbin 001 4

1.14 1AVB

+8.28 F/L 47 70 05/94 RF0 Bobbin 001 4

0.84 17TH TSP

+33.49 F/L 05/94 RF0 Bobbin 001 15 0.84 17TH TSP

+4.53 F/L 47 71 05/94 4F0 Bobbin ADI 4.50 11TH TSP

+20.26 F/L 47 72 05/94 RF0 Bobbin NQI 0.90 2ND TSP

+14.76 F/L 05/94 RF0 Bobbin NOI 1.29 3RD TSP

+6.20 F/L 05/94 RF0 H/L Special Int VOL 0.69 2ND TSP

+16.30 2ND TSP 05/94 RFO M/L Special Int VOL 0.70 3RD TSP

+7.33 3RD TSP 47 74 05/94 RF0 Bobbin ADI 2.58 2ND TSP

+14.40 F/L 05/94 RF0 H/L Special Int VOL 0.56 2ND TSP

+14.11 2ND TSP 47 77 05/94 RF0 Bobbin ADI 2.49 2ND TSP

+4.99 F/L 47 80 05/94 RF0 Bobbin 001 76 0.57 BTH TSP

+ 2. 64 F/L 47 82 05/94 RTO Bobbin ADI 3.0913TH TSP

+33.02 F/L 47 83 05/94 RF0 Bobbin ADI 2.23 12TH TSP

+19.34 F/L 47 86 05/94 RF0 Bobbin ODI 4

0.90 ISTN TSP

+26.71 F/L 47 88 05/94 RF0 Bobbin WAR 10 0.74 2AVB

+0.00 F/L 48 30 05/94 RF0 Bobbin ODI 27 1.10 2ND TSP

+ 27.52 F/L 48 36 05/94 RF0 Bobbin NQI 0.51 2AVB

+41.13 F/L 05/94 RF0 Bobbin NQ1 1.14 2AVB

+22.82 F/L 05/94 RF0 Bobbin NQI 1.66 2AVB

+31.17 F/L 05/94 RF0 U-Bend VOL 0.62 2AVB

+17.08 2AVB 05/94 RF0 U-Bend VOL 0.63 2AVB

+20.65 2AVB 05/94 RF0 U Bend VOL 0.75 2AVB

+27.89 2AVB 48 39 05/94 RF0 Bobbin ODI 7

0.45 7TH TSP

+23.23 F/L 48 40 05/94 RF0 Bobbin NOI 0.69 13TH TSP

+19. 72 F/L 05/94 RF0 C/L Special Int VOL 0.65 12TH TSP

-23.02 12TH TSP 48 42 05/94 RF0 Bobbin 001 18 0.40 11TH TSP

+29.14 F/L 48 49 05/94 RF0 Bobbin NO!

0.74 131H TSP

+5.29 F/L 05/94 RF0 C/L Special Int VOL 0.84 13TH TSP

+5.35 13TH TSP 48 50 05/94 RF0 Bobbin No!

2.55 STH TSP

-3.24 F/L 05/94 RF0 Bobbin Ncl 0.60 12TH TSP

+2.30 F/L 05/94 RF0 Bobbin ODI 11 1.19 BTH TSP

-4.34 F/L 48 55 05/94 RF0 Bobbin ODI a

0.83 7TH TSP

+4.42 F/L 48 68 05/94 RF0 Bobbin 001 19 0.58 9TH TSP

+3.23 F/L 48 74 05/94 RF0 Bobbin 001 15 1.62 11TH TSP

+18.83 F/L 48 86 05/94 RF0 Bobbin 001 17 2.19 4TH TSP

+33.98 F/L 49 41 05/94 RF0 Bobbin N01 1.61 BTH TSP

-1.33 F/L 05/94 RF0 Bobbin 001 8

0.93 BTH TSP

-2.48 F/L 05/94 RTO Bobbin DDI 28 0.62 9TH TSP

-1.48 F/L 05/94 RF0 C/L Special Int VOL 0.37 9TH TSP

-1.77 97H TSP 49 46 05/94 RF0 Bobbin 001 15 2.56 137H TSP

+19.83 F/L 05/94 RF0 C/L Special Int VOL 1.04 13TH TSP

+19.60 137H TSP 49 50 05/94 RF0 Bobbin 0D1 16 0,65 STH TSP

-4.41 F/L 05/94 RF0 Bobbin 001 1

0.71 11TH TSP

+23.74 F/L 49 55 05/94 RF0 Bobbin ODI 10 1.28 7TH TSP

-5.45 F/L 49 60 05/94 kfo Bobbin ADI 1.88 15TH TSP

+17.65 F/L 49 61 05/94 RF0 Bobbin ho!

0.35 13TH TSP

-0.23 F/L 05/94 RF0 C/L Special Int VOL 0.91 13TH TSP

-0.21 13TH TSP 49 66 05/94 RF0 Bobbin 001 9

0.66 12TH TSP

+15.69 F/L

eeeeeeeeeeeeeeee************

BWNS TUBAN 11 (Version 2.0) 06/17/1994 06:22:10 Catawba Nuclear Station - Unit Two ee** ee...*****************

S/G B eeeeeee**................***

05/94 RF0 Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U Bend e............***************

Page 21 of 21

$/G B - ATTACHMENT #2 INDICATIONE OF IMPERFECTIONS ROW COL DUTAGE TEST TYPE IND %TW VOLTS LOCATION EXTENT 1 05/94 RF0 Bobbin 001 10 0.93 10TH TSP

+4.45 F/L 05/94 RF0 Bobbin ODI 35 0.40 12TH TSP

+15.20 F/L 49 69 05/94 RF0 Bobbin No!

0.43 3RD TSP

+24.02 F/L 05/94 RF0 Bobbin 001 22 0.93 4TH TSP

+26.81 F/L 05/94 RF0 Bobbin DDI 1

1.65 17TH TSP

+6.57 F/L 05/94 RF0 H/L Special Int VOL 0.71 4TH TSP

-13.55 4TH TSP 49 72 05/94 RF0 Bobbin 001 20 0.47 7TH TSP

+25.00 F/L 49 73 05/94 RF0 Bobbin 001 25 0.32 7TH TSP

+30.17 F/L 49 74 05/94 RF0 Bobbin NQI 0.B4 6TH TSP

+37.4 9 F/L 05/94 RF0 H/L Special Int VOL 0.90 7TH TSP 6.28 TTH TSP 49 76 05/94 RF0 Bobbin No!

0.70 10TH TSP

+4.66 F/L 49 84 05/94 RF0 Bobbin 001 13 0.82 STH TSP

+31.71 F/L Total Indications Found = 1332 Total Tubes Found = 640

i ATTACIIMENT 3 P

5 I

l 1

i i

J

t BWNS TUBAN !! (version 2.0) 06/17/1994 06:29:03 eeeeeeeee*******************

Catawba Nuclear Station - Unit Two ese*************************

S/G C 05/94 RF0 e............**..,........**

Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U-Bend Page 1 of 27 S/G C

  • ATTACHMENT #3 ]NDICATIONS OF IMPERFECTIONS ROW COL QUTAGE TEST TYPE IND %TW VOLTS LOCATION EXTENT 1 1 13 05/94 RF0 Bobbin NQI 2.40 18TH TSP

+21.34 BTH T'P 05/94 RF0 C/L Special Int VOL 0.56 16TH TSP

-15.78 16TH 117 1 16 05/94 RF0 Bobbin 001 25 0.86 1ST TSP

+4.27 BTH TS 05/94 RF0 H/L Special Int VOL 0.50 1ST TSP

+4.44 iST TSP 1 19 05/94 RF0 Bobbin NQI 0.94 1ST TSP

+21.86 BTH TSP 1 20 05/94 RF0 Bobbin NQ1 0.56 18TH TSP

+29.09 BTH TSP 05/94 RF0 C/L Special Int VOL 1.09 16TH TSP

-7.72 16TH TSP 1 30 05/94 RF0 Bobbin ADI 1.19 4TH TSP

+41.23 BTH TSP 05/94 RF0 Bobbin NOI 0.82 STH TSP

+7.54 BTH TSP 05/94 RF0 Bobbin NQI 1.24 STH TSP

+5.60 87H TSP 05/94 RF0 Bobbin NQI 1.28 STH TSP

+2.02 BTH TSP 05/94 RF0 H/L Special Int VOL 0.56 STH TSP

+5.50 STH TSP 05/94 RF0 H/L Special Int VOL 0.67 5TH TSP

+1.96 STH TSP 05/94 RF0 H/L Special Int VOL 0.86 STH TSP

-1.85 STH TSP 05/94 RF0 H/L Special Int VOL 1.06 STH TSP

+7.51 STH TSP 1 40 05/94 RIO Bobbin NQI 0.77 3RD TSP

+0.38 BTH TSP 05/94 RF0 H/L Special Int VOL 0.85 3RD TSP

+0.77 3RD TSP 1 57 05/94 RF0 Bobbin NQI 0.28 TTS-CL

+4.19 BTH TSP 05/94 RF0 Bobbin 001 2

1.24 18TH TSP

+9.02 BTH TSP 1 62 05/94 RF0 Bobbin NQI 0.73 18TH TSP

+10.95 BTH TSP 05/94 RF0 Bobbin 001 3

1.59 10TH TSP

+19.05 BTH TSP 05/94 RF0 Bobbin ODI 4

0.95 16TH TSP

+26.00 BTH TSP 05/94 RF0 Bobbin ODI 6

1.04 18tH TSP

+17.23 BTH TSP 05/94 RF0 C/L Special Int VOL 0.23 16TH TSP

+26.00 14TH TSP 05/94 RFC C/L Special Int VOL 0.23 18TH TSP

+10.95 16TH TSP 05/94 RF0 C/L Special Int VOL 0.27 18TH TSP

+7.67 16TH TSP 05/94 RF0 C/L Special Int VOL 0.29 187H TSP

+5.89 16TH TSP 05/94 RF0 C/L Special Int VOL 0.30 16TH TSP

+5.98 14TH TSP 05/94 RF0 C/L Special Int VOL 0.30 18TH TSP 0.14 1BTH TSP 05/94 PF0 C/L Special Int VOL 0.34 16TH TSP

+25.79 14TH TSP 05/94 RF0 C/L Special Int VOL 0.56 10TH TSP

+19.16 10TH TSP 05/94 RF0 C/L Special Int VOL 0.66 10TH TSP

+19.05 10TH TSP 05/94 RF0 C/L Special Int VOL 0.90 ISTH TSP

+17.23 16TH TSP 1 67 05/94 RF0 Bobbin ODI 2

0.76 187H TSP

+1.46 87H TSP 05/94 RF0 C/L Special Int VOL 0.61 18TH TSP

-1.15 to

+1.89 18TH TSP 1 64 05/94 RF0 Bobbin ODI 3

0.99 1ST TSP

+27.15 BTH TSP 1 7105/94 RF0 H/L Tubesheet VOL 1.50 TTS-HL

+ 0. 73 TTS-HL 1 73 05/94 RF0 Bobbin 001 20 1.17 13TH TSP

+28.52 81H TSP 05/94 RTO C/L Special Int VOL 0.6013TH TSP

+28.28 13TH TSP 1 98 05/94 RF0 Bobbin ADI 3.45 16TH TSP

+ 7.90 BTH TSP 05/94 RF0 C/L Special Int VOL 0.17 16TH TSP

+10.02 16TH TSP 05/94 RF0 C/L Special Int VOL 0.24 16TH TSP

+20.71 16TH TSP 05/94 RF0 C/L Special Int VOL 0.41 16TH TSP

+ 7. 90 16TH TSP 1 110 05/94 RF0 Bobbin ADI 3.56 6TH TSP

+14.34 8TH TSP 05/94 RF0 H/L Special Int VOL 0.50 6TH TSP

+13.72 6TH TSP 1 111 05/94 RTO Bobbin NQI 2.90 18TH TSP

+16.82 to +33.85 BTH TSP 1 114 05/94 RTO Bobbin ADI 0.74 7TH TSP

+11.94 ETH TSP 05/94 RF0 Bobbin A01 0.78 7TH TSP

+11.97 STH TSP 05/94 RF0 H/L Special Int VOL 0.24 7TH TSP

+11.94 7TH TSP 2 8 05/94 RF0 Bobbin 001 22 1.15 7TH TSP

+7.61 8TH TSP 2 20 05/94 RF0 Bobbin 001 18 1.42 18TH TSP

+23.55 BTH TSP 2 23 05/94 RF0 Bobbin NQI 0.81 13TH TSP

+15.62 BTH TSP 2 31 05/94 RF0 Bobbin 001 15 0.7319TH TSP

+6.68 BTH TSP 2 37 05/94 RF0 Bobbin 001 13 3.26 10TH TSP

+32.29 BTH TSP 2 64 05/94 RF0 Bobbin NQI 0.88 13fH TSP

+5,t4 BTH TSP 05/94 RF0 Bobbin NOI 1.06 13TH TSP

+4 s.

BTH TSP 05/94 RF0 Bobbin NQI 1.15 13TH TSP

+3.11 BTH TSP 05/V4 RF0 Bobbin NO!

1.44 13TH TSP

+1.81 STH TSP 05/94 RF0 C/L Special Int VOL 0.32 137H TSP

+5.64 13TH TSP 05/94 RF0 C/L Special Int VOL 0.61 13TH TSP

+1.42 137H TSP 05/94 RF0 C/L Special Int VOL 0.66 13TH TSP

+0.35 13TH TSP 05/94 RF0 C/L Special Int VOL 0.77 13fH TSP

+2.48 13TH TSP 05/94 RF0 C/L Specist Int VOL 0.77 13TH TSP

+4.51 13TH TSP 05/94 RF0 C/L Special Int VOL 0.81 13TH TSP

+3.54 13TH TSP 2 65 05/94 RF0 Bobbin DDI 5

1.4711TH TSP

+20.41 STH TSP 2 66 05/94 RF0 Bobbin 001 11 1.83 16TH TSP

+18.77 bTH TSP

eeeeeeeeeeeeeee.************

BWNS TUBAN !! (Version 2.0) 06/17/1994 06:29:03

    • eeeee*eeeeeeeeeeeeeeeeeeem eeeeeeeeeeen.ee.......... **

Catawba Nuclear Station Unit two

      • eeeee.....*.............*

S/G C

e..........................

o$f94 RF0 eeeeeeee............********

Bobbin,C/L Speclat Interest,H/L Special Interest,H/L Tubesheet,U Bend Pa9e 2 of 27 S/G C ATTACHMENT #3 INDICATIONS OF IMPERFECTIONS ROW COL OUTAGE TEST TYPE IND %TW VOLTS LOCATION EXTEN11 2 68 05/94 RF0 Bobbin NQI 0.56 2ND TSP

-1.63 BTH TSP 05/94 RF0 H/L Special Int VOL 0.98 2ND TSP

-1.63 2ND TSP l

2 73 05/94 RF0 Bobbin ADI 5.60 41H ISP

+2.97 BTH TSP 05/94 RF0 H/L Special Int VOL 1.09 4TH TSP

+2.63 4TH TSP l

2 74 05/94 RF0 Bobbin NQI 2.80 12TH TSP

+30.17 BTH TSP l

05/94 RF0 Bobbin No!

3.10 121H TSP

+29.17 BTH TSP l

05/94 RF0 C/L Special Int VOL 1.10 121H TSP

+28.94 11TH TSP 05/94 RF0 C/L Special Int VOL 1.88 12TH ISP

+29.80 11TH TSP 2 75 05/94 RF0 Bobbin ADI 4.57101H TSP

+13.92 BiH TSP 05/94 RF0 C/L Special Int VOL 0.70 10TH TSP

+13.68 10TH TSP 2 76 05/94 RF0 Bobb'a Af" 7.38 6TH TSP

+35.48 BTH TSP 05/94 RF0 H/L special Int "0L 0.63 7TH TSP

-10.52 7TH TSP 2 82 05/94 RF0 Bobbin 001 9

1.00 16TH TSP

+34.62 BTH TSP i

2 84 05/94 RF0 Bobbin No!

0.46 6TH TSP

+1.84 BTH TSP

)

05/94 RF0 H/L Special Int VOL 0.66 6TH TSP

+1.84 6TH TSP 2 102 05/94 RF0 Bobbin NQ1 0.93 11TH TSP

+20.32 8TH TSP 05/94 RF0 C/L Special Int VOL 1.40 11TH TSP

+20.32 11TH TSP 2 106 05/94 RF0 Bobbin ADI 5.14 13TH TSP

+14.47 8TH TSP 05/94 RF0 C/L Special Int VOL 1.19 13TH TSP

+14.47 13TH TSP 2107 05/94 RIO Bobbin 001 4

0.89 STH TSP

+12.62 BTH TSP 3 17 05/94 RF0 Bobbin ADI 9.42 71H TSP

+32.33 BTH TSP 05/94 RF0 H/L Special Int VOL 0.51 7TH TSP

+34.03 7TH TSP 05/94 RF0 H/L Special Int VOL 1.51 71H TSP

+29.30 7TH TSP 3 23 05/94 RF0 Bobbin ADI 17.54 197H TSP 0.91 BTH TSP 05/94 RF0 C/L Special Int VOL 1.26 19TH TSP 0.29 19TH TSP 3 27 05/94 RIO Bobbin ODI 17 3.08 14TH TSP

+8.56 BTH TSP 3 37 05/94 RF0 Bobbin ODI 20 0.28 131H TSP

+0.71 BTH TSP 3 94 05/94 RF0 Bobbin ADI 0.67 16TH TSP

+9.80 BTH TSP 3 97 05/94 RF0 Bobbin ADI 5.20 13TH TSP

+14.59 BTP TSP 05/94 RF0 Bobbin ADI 7.03 18TH TSP

+12.18 81H TSP 05/94 RF0 C/L Spacial Int VOL 1.25 13TH TSP

+14.37 13TH TSP 05/94 RF0 C/L Special Int VOL 2.19 18TH TSP

+12.14 17TH TSP 4 15 05/94 RF0 Bobbin NQ1 0.37 12TH TSP

+0.76 STH TSP 4 23 05/94 RF0 Bobbin 001 3

1.25 15fH TSP

+10.55 BTH TSP 4 27 05/94 RF0 Bobbin ADI 2.80 51H TSP

+23.88 8TH TSP 05/94 RF0 Bobbin ADI 2.89 STH TSP

+39.52 BTH TSP 05/94 RF0 Bobbin ADI 3.62 STH TSP

+11.61 BTH TSP 05/94 RF0 Bobbin ODI 10 1.16 STH TSP

+21.45 BTH TSP 05/94 RF0 Bobbin 0D1 18 3.40 STH ISP

+19.16 BTH ISP 05/94 RF0 Bobbin 001 22 0.82 STH TSP

+26.99 BTH TSP 05/94 RF0 H/L Special Int VOL 0.51 STH TSP

+23.10 STH TSP 05/94 RF0 H/L Special Int VOL 0.66 STH ISP

+20.78 51H TSP 05/94 RF0 H/L Spectat Int VOL 0.79 STH TSP

+26.09 STH TSP 05/94 RF0 H/L Special Int VOL 1.09 STH TSP

+38.56 STH TSP 05/94 RF0 H/L Special Int vol 1.21 STH TSP

+11.37 STH TSP 05/94 RF0 H/L Special Int VOL 1.97 STH TSP

+18.55 STH TSP 4 38 05/94 RF0 Bobbin ADI 4.35 1ST TSP

+11.15 BTH TSP 05/94 RF0 H/L Speciel Int VOL 1.77 1ST TSP

+11.96 1ST TSP 4 39 05/94 RF0 Bobbin ADI 3.59 TTS-HL

+2.98 BiH TSP 05/94 RF0 H/L Tubesheet VOL 0.58 TTS HL

+2.93 TIS HL 05/94 RF0 H/L Special Int VOL 0.78 TTS HL

+2.68 TTS-HL 4 69 05/94 RF0 Bobbin ADI 2.58 BTH TSP

+9.35 BTH TSP 4 78 05/94 RF0 Bobbin ADI 5.44 10TH TSP

+24.90 81H TSP j

05/94 RF0 Bobbin ADI 11.54 11TH TSP

+31,25 BTH TSP 05/94 RTO C/L Special Int VOL 0.80 10TH TSP

+24.93 10TH TSP 05/94 RF0 C/L Special Int VOL 0.89 11TH TSP

+30.96 111H 1SP 4 84 05/94 RF0 Bobbin ODI 17 1.80 10TH TSP

+39.98 BTH ISP J

4 98 05/94 RF0 Bobbin ADI 4.26 12TH TSP

+ 7.55 BTH TSP 1

4 113 05/94 RF0 Bobbin ADI 11.00 16TH TSP

+3.40 81H TSP 05/94 RF0 C/L Special Int VOL 0.75 16TH TSP

+1.78 16TH TSP 05/94 RF0 C/L Special Int VOL 1.30 16TH TSP

+3.21 16TH TSP 4 114 05/94 RF0 Bobbin 001 8

1.23 10TH TSP

+40.85 81H TSP 5 9 05/94 RF0 Bobbin ODI 12 0.52 131H TSP

+7.94 F/L 5 15 05/94 RF0 Bobbin 001 13 0.81 13TH TSP

+14.67 F/L 05/94 RF0 C/L Special Int VOL 0.24 131H TSP

+14.67 13TH TSP 5 32 05/94 RF0 Bobbin ADI 7.20 4TH TSP

+8.62 F/L

]

=

BWNS TUBAN 11 (version 2.0) 06/17/1994 06:29:03

  • eee************************

Catawba Nuclear Station - Unit Two esesseeessesesseessessesseee eseeeeese.seesessessessee..

syg g eeeeeeeees.sosse..ee.ees.***

05/94 RF0

~

Bobbin,C/L Special Interest,H/L Special Interest.H/L Tubesheet,U-Bend e eessee.e.***.e.***********

Page 3 of 27

$/G C ATTACHMENT #3 INDICATIONS OF !MPERFECTIONS ROW COL DUTAGE TEST TYPE IND %TW VOLTS LOCATION EXTENT 1 I

1 05/94 RF0 N/L Speclat Int VOL 0.73 4TH TSP

+B.82 4TH TSP 5 49 05/96 AFO Bobbin NQI 0.46 14TH TSP

-1.01 F/L 5 64 05/94 RF0 Bobbin 001 12 1.10 11TH TSP

+7.48 F/L 5 87 05/94 RF0 Bobbin 001 20 1.23 3RD TSP

+28.31 F/L 05/94 RF0 Bobbin 001 29 0.72 STH TSP

+21.10 r/L 5 92 05/94 RF0 Bobbin DDI 11 0.82 13TH TSP

+2.77 F/L 5 101 05/94 RF0 Bobbin ODI 4

1.90 1ST TSP

+22.36 F/L 5 104 05/94 RF0 Bobbin DDI 15 1.00 4TH TSP

+25.17 F/L 05/94 RF0 Bobbin DDI 15 1.98 6TH TSP

+5.72 F/L 5 107 05/94 RF0 Bobbin 001 23 0.93 TTS HL

+5.94 F/L 5 til 05/94 RF0 Bobbin 001 8

1,29 13fH TSP

+16.38 F/L 5 114 05/94 RF0 Bobbin 001 5

1.15 71H TSP

+28.11 F/L 05/94 RF0 Bobbin 001 21 0.95 9TH TSP

-3.86 F/L l

05/94 RF0 Bobbin 001 14 0.86 10TH TSP

+25.87 F/L 6 4 05/94 RF0 Bobbin 001 2

0.93 7TH TSP

+0.60 F/L 6 8 05/94 RF0 Bobbin 001 4

0.71 TTH TSP

+29.76 F/L 05/94 RF0 H/L Spectat Int VOL 0.95 TTH TSP

+29.48 7TH TSP 6 14 05/94 RF0 Bobbin ADI 3.62 4TH TSP

+4.21 F/L 05/94 RF0 Bobbin 001 25 0.75 3RD TSP

+2.64 F/L 05/94 RF0 H/L Special Int VOL 1.18 4TH TSP

+4.24 4TH TSP 6 39 05/94 RF0 Bobbin ADI 3.43 TTH TSP

+ 7. 26 F/L 05/94 RF0 H/L Special Int VOL 0.72 71H TSP

+ 7. 76 7TH TSP 6 42 05/94 RF0 Bobbin 001 10 0.65 BTH TSP

+2.54 F/L 6 89 05/94 RF0 Bobbin 001 27 0.41 3RD TSP

+16.49 F/L 6 92 05/94 RF0 Bobbin 001 14 1.34 STH TSP

+20.28 F/L 6 98 05/94 RF0 Bobbin DDI 4

1.22 11TH TSP

+6.62 F/L 6 99 05/94 RF0 Bobbin 001 19 1.12 3RD TSP

+18.62 F/L 05/94 RF0 H/L Special Int VOL 0.77 4TH TSP

-16.98 4TH TSP 7 31 05/94 RF0 Bobbin 001 2

1.96 71H TSP

+12.49 F/L 05/94 RF0 Bobbin 001 9

1.99 10TH TSP

+11.49 F/L 7 35 05/94 RF0 Bobbin 001 12 1.53 TTS-CL

+5.13 F/L 05/94 RF0 Bobbin 001 26 1,38 18TH TSP

+16.16 F/L 05/94 RF0 C/L Special Int VOL 0.35 197H TSP

-3.62 19TH TSP 05/94 RF0 C/L Special Int VOL 0.70 17TH TSP 2.30 17TH TSP 7 38 05/94 RF0 Bobbin ADI 1,47 4TH TSP

+21.53 F/L 05/94 RF0 H/L Special Int VOL 0.32 4TH TSP

+22.27 4TH TSP 7 39 05/94 RF0 Bobbin DDI 13 3.67 4TH TSP

+4.15 F/L 7 41 05/94 RF0 Bobbin ADI 1,46 1ST TSP

+11.26 F/L 05/94 RF0 Bobbin 001 17 0.79 6TH TSP

+3.80 F/L 05/94 RF0 Bobbin 001 23 0.63 1ST TSP

+3.41 F/L 05/94 RF0 Bobbin DDI 34 0.71 2ND TSP

+19.56 F/L 05/94 RF0 H/L Special Int VOL 0.30 1ST TSP

+4.52 2ND TSP 05/94 RF0 H/L Special Int VOL 0.51 1ST TSP

+3.08 2ND TSP 05/94 RfD H/L Special Int VOL 0.58 1ST TSP

+10.70 2ND TSP 7 44 05/94 RF0 Bobbin ODI 13 0.72 1ST TSP

+11.86 F/L 7 64 05/94 RF0 Bobbin ADI 1,58 10TH TSP

+31.25 F/L 05/94 RF0 C/L Special Int VOL 0.69 91H TSP

-15.23 91H TSP 05/94 RF0 C/L Special Int VOL 0.88 9TH TSP

-16.07 9TH TSP 05/94 RF0 C/L Special Int VOL 0.93 97H TSP

-11.72 91H TSP 7 71 05/94 RF0 Bobbin ADI 0.84 131H TSP

+7.63 F/L 05/94 RF0 Bobbin 001 7 2.27131H TSP

+13.09 F/L 05/94 RF0 C/L Spectat Int VOL 0.32 13TH TSP

+1.33 13TH TSP 05/94 RF0 C/L Special Int VOL 0.45 13TH TSP

+3.74 13fH TSP 05/94 RF0 C/L Special Int VOL 0.46 13fH TSP

+ 7. 51 13fH TSP 05/94 RF0 C/L Specist Int VOL 0.53 131H TSP

+13.05 131H TSP 7 81 05/94 RF0 Bobbin 001 2

2.41 14TH TSP

+9.67 F/L 7 83 05/94 RF0 Bobbin 001 19 0.47 12TH TSP

+10.94 F/L 05/94 RF0 Bobbin 001 31 0.3712TH TSP

+8.02 F/L 7 B4 05/94 RF0 Bobbin 001 7

3.18 11TH TSP

+22.27 F/L l

7 104 05/94 RF0 Bobbin ADI 5.44 STH TSP

+19.75 F/L 05/94 RF0 H/L Special Int VOL 1.06 STH TSP

+ 19. 75 STH TSP 8 2 05/94 RF0 Bobbin ADI 5.37 4TH TSP

+9.14 F/L 05/94 RF0 H/L Speclat Int VOL 1.69 4TH TSP

+9.12 4TH TSP 8 10 05/94 RF0 Bobbin DDI B

1.27 STH TSP

+15.95 F/L 8 14 05/94 RF0 Bobbin No!

D.42 10TH TSP

+17.79 F/L 05/94 RF0 C/L Special Int VOL 0.17 10TH TSP

+17.79 10TH TSP

BWNS TUBAN II (Version 2.0) 06/17/1994 06:29:03 Catawba Nuclear Station - Unit Two eeeeewee.******************

S/G C 05/94 RF0 Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U-Bend Page 4 of 27 S/G C - ATTACHMENT #3 INDICATIONS OF IMPERFECTIONS ROW COL OUTACE TEST TYPE IND %TW VOLTS LOCATION EXTENT 1 8 16 05/94 RF0 Bobbin 001 7

1.21 16TH TSP

+11.91 F/L 8 31 05/94 RF0 Bobbin 001 19 0.69 STH TSP

+29.58 F/L 8 40 05/94 RF0 Bobbin NQI 0.58 13TH TSP

+11.92 F/L 8 46 05/94 RF0 Bobbin 001 20 0.89 7TH TSP

+19.92 F/L 8 49 05/94 RF0 Bobbin 001 26 0.35 1STH TSP

+9.53 F/L 8 50 05/94 RF0 Bobbin ADI 2.97 STH TSP

+1.31 F/L 05/94 RF0 Bobbin ADI 1.80 15TH TSP

+12.38 F/L 05/94 RF0 Bobbin 001 16 0.75 3RD TSP

+20.82 F/L 05/94 RF0 Bobbin 001 17 0.94 3RD TSP

+26.13 F/L 05/94 RF0 H/L Special Int YOL 1.26 STH TSP

+1.41 STH TSP 05/94 RF0 H/L Special Int VOL 1.97 STH TSP

+0.89 STH TSP 8 71 05/94 RF0 Bobbin ADI 12.85 2ND TSP

+10.41 F/L 05/94 RFC H/L Special Int VOL 0.96 2ND TSP

+10.41 2ND TSP 8 76 05/94 RF0 Bobbin Nol 1.57 STH TSP

+33.16 F/L 05/94 RF0 H/L Special Int VOL 2.20 6TH TSP

-9.84 6TH TSP 8 83 05/94 RF0 Bobbin 001 34 0.87 12TH ISP

+28.10 F/L 8 84 05/94 RF0 Bobbin ADI 1.98 12TH TSP

+11.30 F/L 05/94 RF0 C/L Special Int VOL 0.39 12TH TSP

+8.90 12TH ISP 8 85 05/94 RF0 Bobbin ADI 8.22 1ST TSP

+22.29 F/L 05/94 RF0 H/L Special Int VOL 1.84 2ND TSP

-5.91 2ND TSP 8 87 05/94 RF0 Bobbin 001 11 0.63 10TH TSP

+16.31 F/L 8 96 05/94 RF0 Bobbin ADI 7.47 16TH TSP

+12.16 F/L 05/94 7FO C/L Special int VOL 2.84 16TH TSP

+11.95 16TH TSP 8 103 05/94 RF0 Bobbin 001 13 0.85 16TH TSP

+10.48 F/L 8 110 05/94 RF0 Bobbin ADI 2.93 STH TSP

+26.61 F/L 05/94 RFO H/L Special Int VOL 0.56 STH TSP

+26.61 STH TSP 8 111 05/94 RTO Bobbin 001 14 0.60 10TH TSP

+28.79 F/L 9 8 05/94 RF0 Bobbin ODI 24 1.5711TH TSP

+34.61 F/L 05/94 RF0 C/L Special Int VOL 0.75 10TH TSP

-9.91 10TH TSP 9 18 05/94 RF0 Bobbin 001 24 1.14 10TH TSP

+24.75 F/L 9 35 05/94 RF0 H/L Tubesheet SAI 0.21 TTS-HL

-0.06 TTS-HL 9 38 05/94 RF0 Bobbin NQ1 2.35 2ND TSP

+11.53 F/L 05/94 RF0 H/L Special Int VOL 3.85 2ND TSP

+11.70 2ND TSP 9 41 05/94 RF0 Bobbin No!

0.98177H TSP

+B.59 F/L 05/94 RF0 C/L Special Int VOL 0.52 17TH TSP

+8.71 17TH TSP 9 42 05/94 RF0 Bobbin 001 1

1.45 BTH TSP

+3,37 F/L 9 49 05/94 RF0 Bobbin ODI 18 2.82 7TH TSP

+6.72 F/L 9 67 05/94 RF0 Bobbin 001 27 0.49 10TH TSP

+26.42 F/L 9 84 05/94 RF0 Bobbin 001 35 0.47 4TH TSP

+22.33 F/L 9 88 05/94 RF0 Bobbin DDI 9

0.90 18TH TSP

+16.82 F/L 9 98 05/94 RF0 Scbbin 001 11 1.16 7TH TSP

+19.71 F/L 9 112 05/94 RF0 Bobbin 001 18 1.21 4TH TSP

+30.66 F/L 05/94 RF0 Bobbin 001 24 0.97 3RD TSP

+21.02 F/L i

05/94 RTO Bobbin 001 26 0.94 3RD TSP

+21.71 F/L 05/94 RF0 Bobbin ADI 1.99 STH TSP

+2.39 to +20.83 F/L 05/94 RF0 H/L Special Int VOL 0.44 4TH TSP

-14.85 4TH TSP 05/94 RF0 H/L Special Int VOL 0.47 STH TSP

+5.00 STH TSP 05/94 RF0 H/L Special Int VOL 0.51 STH TSP

+6.00 STH TSP 05/94 RF0 H/L Special Int VOL 0.58 5TH TSP

-11.02 STH TSP 05/94 RF0 H/L Special Int VOL 0.62 STH TSP

-7.09 STH TSP 05/94 RF0 H/L Special Int VOL 0.64 STH TSP

+2.94 STH TSP 05/94 RF0 H/L Special Int VOL 0.68 5TH TSP

+11.97 STH TSP 05/94 RF0 H/L Special Int VOL 0.75 STH TSP

+7.21 STH TSP 05/94 RF0 H/L Special Int VOL 0.84 STH TSP

-13.00 5TH TSP 05/94 RF0 H/L Special Int VOL 0.85 STH TSP

+8.98 STH TSP 05/94 RF0 H/L Special Int VOL 1.16 STH TSP

+ 9. 75 STH TSP 10 4 05/94 RF0 Bobbin NQI 0.42 13TH TSP

+14.18 F/L 05/94 RF0 Bobbin 001 17 2.13 15TH TSP

+6.10 F/L 05/94 RF0 C/L Special Int VOL 0.59 13TH TSP

+14.18 13TH TSP 10 11 05/94 RF0 Bobbin kol 2.13 2ND TSP

+11.06 F/L 05/94 RF0 H/L Special Int VOL 1.59 2ND TSP

+10.78 2ND TSP 10 20 05/94 RF0 Bobbin ADI 2.60 14TH TSP

+14.14 F/L 05/94 RF0 C/L Specist Int VOL 0.63 13TH TSP

-4.59 13TH TSP 10 22 05/94 RF0 Bobbin 001 16 0.60 1ST TSP

+6.78 F/L 10 43 05/94 RF0 Bobbin 001 33 1.29 13TH TSP

+23.95 F/L 05/94 RF0 C/L Special Int VOL 0.6513TH TSP

+22.99 13TH TSP 1

i eeee***e.........***********

BWNS TUBAN II (Version 2.0) 06/17/1994 06:29:03 eeeeee**********************

Catawba Nuclear Station Unit Two 1

S/G C 05/94 RF0 Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U-Bend j

l 1

Page 5 of 27 l

S/G C ATTACHMENT #3 INDICATIONS OF IMPERFECTIONS ROW COL DUTACE TEST TYPE IND %TW VOLTS LOCATION EXTENT 1 10 49 05/94 RF0 Bobbin 001 13 0.73 157 TSP

+5.06 F/L l

05/94 RF0 Bobbin 001 6

1.11 13TH TSP

+18.05 F/L 10 51 05/94 RF0 Bobbin WQI 0.73 17TH TSP

+16.43 F/L 05/94 RF0 C/L Special Int VOL 0.41 16TH TSP

-1.65 16TH TSP 10 59 05/94 RF0 Bobbin 001 28 0.92 12TH TSP

+37.62 F/L 10 69 05/94 RF0 Bobbin 001 24 1.21 12TH TSP

+30.11 F/L 05/94 RF0 C/L Special Int VOL 1.18 12TH TSP

+29.73 11TH TSP 10 79 05/94 RF0 Bobbin 001 29 0.95 13TH TSP

+23.61 F/L 05/94 RF0 C/L Special Int VOL 1.04 13TH TSP

+23.85 13fH TSP 10 81 05/94 RF0 Bobbin NQI 0.72 17TH TSP

+12.19 F/L 05/94 RF0 Bobbin 001 23 0.B4 13TH TSP

+8.53 F/L 05/94 RF0 C/L Special Int VOL 0.28 17TH TSP

+14.95 16TH TSP 05/94 RF0 C/L Special Int VOL 0.43 17TH TSP

+12.78 16TH TSP 05/94 RF0 C/L Special Int VOL 0.53 17TH TSP

+12.11 16TH TSP 10 84 05/94 RF0 Bobbin ADI 3.65 10TH TSP

+25.88 F/L 05/94 RF0 C/L Special Int VOL 1.15 10TH TSP

+25.79 10TH TSP 10 112 05/94 RF0 Bobbin 001 14 0.69 7TH TSP

+34.15 F/L 11 21 05/94 RF0 Bobbin ADI 11.29 7TH TSP

+27.67 F/L 05/94 RF0 H/L Special Int VOL 5.65 7TH TSP

+ 27.5 7 TTH TSP 11 41 05/94 RF0 Bobbin 001 26 0.55 11?H TSP

+4.88 F/L 11 61 05/94 RF0 Bobbin DDI 1

0.75 77H TSP

+31.66 F/L 05/94 RF0 Bobbin 001 13 0.60 7TH TSP

+25.76 F/L 05/94 RF0 Bobbin 001 4

1.16 10TH TSP

+28.20 F/L 05/94 RF0 Bobbin 001 8

1.02 10TH TSP

+38.52 F/L 05/V4 RF0 H/L Special Int VOL 1.62 BTH TSP

-17.42 BTH TSP 05/94 RF0 H/L Special Int VOL 1.95 BTH TSP

-11.03 BTH TSP 11 65 05/94 RF0 Bobbin ADI 2.78 7TH TSP

+7.93 F/L 05/94 RF0 Bobbin 001 6

1.271TTH TSP

+7.14 F/L 11 68 05/94 RF0 Bobbin NQI 1,62 6TH TSP

+30.34 F/L l

05/94 RF0 Bobbin 001 5

1.67 6TH TSP

+16.49 F/L 05/94 RF0 H/L Special Int VOL 1.42 7TH TSP 15.99 71H TSP 05/94 RF0 H/L Special Int VOL 2.82 7TH TSP

-13.25 7TH TSP 11 83 05/94 RF0 Bobbin DDI 4

2.69 14TH TSP

+12.15 F/L I

11 87 05/94 RF0 Bobbin ADI 6.67 171H TSP + 10.47 F/L 05/94 RF0 C/L 3pecial Int VOL 0.81 17TH TSP

+9.77 16TH TSP 11 93 05/94 RF0 Bobbin ADI 1.19 3RD TSP

+26.21 F/L 05/94 RF0 Bobbin AD) 4.71 3RD TSP

+25.20 F/L 05/94 RF0 Bobbin 001 14 1.72 16TH TSP

+9.54 F/L 05/94 RF0 H/L Special Int VOL 0.42 3RD TSP

+ 26. 75 3RD TSP 05/94 RF0 H/L Special Int VOL 0.79 3RD TSP

+26.00 3RD TSP 05/94 RF0 H/L Special Int VOL 1.39 3RD TSP

+12.98 3RD TSP 11 98 05/94 RF0 Bobbin OD) 20 1.87 6TH TSP

+22.30 F/L 11 102 05/94 RF0 Bobbin DDI 14 0.75 18TH TSP

+5.50 F/L 05/94 RF0 Bobbin OD!

15 1.24 13TH TSP

+17.63 F/L 11 107 05/94 RF0 Bobbin 001 11 2.4? 2ND TSP

+31.46 F/L 11 112 05/94 RF0 Bobbin 001 11 2.87 10iH TSP

+26.46 F/L 05/94 RF0 Bobbin ODI 13 3.55 10TH TSP

+ 7.56 F/L 12 15 05/94 RF0 Bobbin NQI 0.77 FTS-HL

+3.69 F/L 05/94 RF0 Bobbin NQI 1,76 TTS HL

+3.08 F/L 05/94 RF0 H/L Special Int VOL 1.98 TTS-HL

+3.32 TTS-HL 12 30 05/94 RF0 Bobbin DDI 28 0.46 13TH TSP

+15.13 F/L 12 31 05/94 RF0 Bobbin ODI 3

1.57 7TH TSP

+30.17 F/L 12 37 05/94 RF0 Bobbin 001 14 0.79 7TH TSP

+31.21 F/L 12 41 05/94 RF0 Bobbin 001 17 3.2617TH TSP

+ 7.59 F/L 12 54 05/94 RF0 Bobbin ADI 8.75 3RD TSP

+21.08 F/L 05/94 RF0 H/L Special Int VOL 1.57 3RD TSP

+21.56 3RD TSP 12 56 05/94 RFC Bobbin 001 12 2.20 1ST TSP

+15.48 F/L 05/94 RF0 H/L Special Int VOL 1.67 15T

.P

+15.12 1ST TSP 12 59 05/94 RF0 Bobbin ADI 3.26 " t e ISP

+6.53 F/L 05/94 RTO C/L Special Int VOL

0. 00 o;1H TSP

+6.53 15fH TSP 12 69 05/94 RF0 H/L Tubesheet VOL 0.3 lIS-HL 0.17 TTS-ML 12 89 05/94 RF0 Bobbin 001 4

1.13 11TH TSP

+18.60 F/L 12 93 05/9= RF0 Bobbin ADI 3.35 STH TSP

+4.29 to

+9.71 F/L 05/94 RTO H/L Special Int VOL 0.75 STH TSP

+7.25 STH TSP 05/94 RF0 H/L Special Int V9L 0.88 STH TSP

+4.66 STH TSP 05/94 RF0 H/L Special Int VOL 0.95 STH TSP

+G 63 STH TSP

BWNS TUBAN 11 (Version 2.0) 06/17/1994 06:29:03 Catawba Nuclear Station - Unit Two S/G C 05/94 RF0 Bobbin,C/L Special Interest,H/L Spezial Interest,H/L Tubesheet,U-Bend Page 6 of 27 S/G C - ATTACHMENT #3 INDICATIONS OF IMPERFECTIONS ROW COL DUTAGE TEST TYPE IND %TW VOLTS LOCATION EXTENT 1 05/94 RF0 H/L Special Int VOL 0.96 STH TSP

+ 1. 73 STH TSP 05/94 RF0 H/L Special Int VOL 0.96 STH TSP

+10.14 STH TSP 05/94 RF0 H/L Special Int VOL 1.06 STH TSP

+6.14 STH TSP 05/94 RF0 H/L Special Int VOL 1.07 STH TSP

+3.09 STH TSP 12 98 05/94 RF0 Bobbin NQI 0.69 6TH TSP

+19.36 F/L 12 102 05/94 RF0 Bobbin 001 8

0.58 17TH TSP

+9.02 F/L 12 111 05/94 PF0 Bobbin Nol 1.0617TH TSP

+2.62 F/L 05/94 RF0 Bobbin 001 9

0.63 10TH TSP

+38.74 F/L 05/94 RF0 C/L Special Int VOL 0.45 10TH TSP

+35.75 9TH TSP 05/94 RF0 C/L Special Int VOL 0.45 17TH TSP

+2.71 17TH TSP 12 113 05/94 RF0 Bobbin DDI 21 0.38 7TH TSP

+19.72 F/L 13 6 05/94 RF0 Bobbin 001 6

0.79 7TH TSP

+25.42 F/L 05/94 RF0 Bobbin ODI 8

0.50 77H TSP

+34.79 F/L 05/94 RF0 Bobbin 001 8

0.54 7TH TSP

+29.89 F/L 05/94 RF0 Bobbin 001 37 0.28 7TH TSP

+40.38 F/L 05/94 RF0 H/L Special Int VUL 2.00 BTH TSP

+2.26 BTH TSP 13 8 05/94 RF0 Bobbin No!

0.52 7TH TSP

+13.87 F/L 05/94 RF0 Bobbin NQI 0.45 10TH TSP

+ 7. 28 F/L 05/94 RF0 Bobbin 001 11 0.93 7TH TSP

+8.56 F/L 05/94 RF0 Bobbin DDI 12 1.90 10TH TSP

+14.03 F/L 05/94 RF0 H/L Special Int VOL 1.20 7TH TSP

+13.82 7TH TSP 13 9 05/94 RF0 Bobbin No!

0.41 7TH TSP

+28.07 F/L 05/94 RF0 Bobbin 001 19 1.11 2ND TSP

+12.03 F/L 05/94 RF0 M/L Special Int VOL 0.71 7TH TSP

+28.60 7TH TSP 13 15 05/94 RF0 Bobbin ODI 3

1.29 10TH TSP

+10.17 F/L 05/94 RF0 Bobbin 001 5

1.92 11TH TSP

+34.75 F/L 05/94 RFC Bobbin 001 7

1.74 10TH TSP

+8.45 F/L 05/94 RF0 Bobbin 001 8

2.19 10TH TSP

+6.09 F/L 05/94 RF0 Bobbin 001 12 0.49 11TH TSP

+40.01 F/L 05/94 RF0 Bobbin ODI 16 0.83 10TH TSP

-1.53 F/L 05/94 RF0 Bobbin 001 17 0.37 10TH TSP

+2.95 F/L 05/94 RF0 Bobbin 001 18 1.19 11TH TSP

+28.55 F/L 05/94 RF0 Bobbin 001 28 0.77 10TH TSP

-1.80 F/L 13 34 05/94 RF0 Bobbin DDI 18 0.58 17TH TSP

+12.08 F/L 13 35 05/94 RF0 Bobbin NQI 0.34 6TH TSP

+39.66 F/L 05/94 RF0 Bobbin NQI 0.31 11TH TSP

+34.54 F/L 05/94 RF0 Bobbin DDI 6

1.42 10TH TSP

+7.72 F/L 05/94 RF0 Bobbin 001 25 0.53 11TH TSP

+29.61 F/L 05/94 RF0 Bobbin 001 30 0.90 10TH TSP

+2.98 F/L 05/94 RF0 H/L Special Int VOL 1.57 71H TSP

- 2. 75 71H TSP 13 78 05/94 RF0 Bobbin No!

0.60 19TH TSP

+6.85 F/L 05/94 RF0 Bobbin No!

0.85 19TH TSP

+7.76 F/L 05/94 RF0 Bobbin DDI 24 1.88 18TH TSP

+0.71 F/L 05/94 RF0 C/L Special Int VOL 0.90 19TH iso

+f.84 18TH TSP 05/94 RF0 C/L Special Int VOL 1.25 19TH TSP

+7.89 18TH TSP 13 89 05/94 RF0 Bobbin 001 9

1.27 /TH TSP

+25.22 F/L i

13 91 05/94 RF0 Bobbin ADI 4.49 1ST TSP

+11.00 t/L 05/94 RF0 Bobbin 001 17 1.09 16TH TSP

+10.40 F/L 05/94 RF0 H/L Special Int VOL 0.27 iST TSP

+10.90 1ST TSP 05/94 RF0 C/L Special Int VOL 0.75 16TH TSP

+10.58 15TH TSP 13 101 05/94 RF0 Bobbin 001 23 0.52 12TH TSP

+9.82 F/L 13 110 05/94 RF0 Bobbin 001 14 0.89 12TH TSP

+2.58 F/L 05/94 RF0 C/L Special Int VOL 0.55 12TH TSP

+2.41 12TH TSP 13 111 05/94 RF0 Bobbin 001 16 0.39 10TH TSP

+32.50 F/L 14 6 05/94 RF0 Bobbin DDI 4

1.26 71H TSP

+36.15 F/L 05/94 RF0 Bobbin 001 6

1.14 7TH TSP

+40.91 F/L 05/94 RF0 Bobbin 001 4

1.77 10TH TSP

+23.14 F/L 14 16 05/94 RF0 Bobbin DDI 12 1.05 4TH TSP

+7.53 F/L 05/94 RF0 H/L Special Int VOL 1.44 4TH TSP

+7.47 4TH TSP 14 17 05/94 RF0 Bobbin NQI 0.66 18TH TSP

+3.23 F/L 05/94 RF0 Bobbin 001 6

0.75 197H TSP

+3.96 F/L 05/94 RF0 Bobbin ODI 17 0.80 18TH TSP

+ 4. 73 F/L 05/94 RF0 Bobbin 001 19 1.35 18TH TSP

+0.89 F/L 05/94 RF0 C/L Special Int VOL 0.30 1BTH TSP

+3.23 18TH TSP 05/94 RF0 C/L Special Int VOL 0.52 18TH TSP

+0.85 18TH TSP 14 19 05/94 RF0 Bobbin NQ1 0.42 3RD TSP

+0.05 F/L 1

g.

BWNS TUBAN II (Version 2.0) 06/17/1994 06:29:03 eeeeeeeeeeeeeeeeeeeeeee*****

Catawba Nuclear Station

  • Unit Two eeeeeeee********************

S/G C eseeeeeeee**ee........e*****

05/94 RF0 Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U-Bend Page 7 of 27 S/G C ATTACHMENT #3 INDICATIONS OF IMPERFECTIONS R0W COL OUTAGE TEST TYPE IND %TW VOLTS LOCATION EXTENT 1 05/94 RF0 Bobbin ADI 4.54 197H TSP

-1.69 F/L 05/94 RF0 H/L Special Int VOL 0.94 3RD TSP

+0.03 3RD TSP 05/94 RF0 C/L Special Int VOL 0.61 19TH TSP

-1.34 19TH TSP 14 20 05/94 RF0 Bobbin 001 7

2.30 13fH TSP

-9.12 F/L 05/94 RF0 C/L Special Int VOL 1.99 13TH TSP

-9.95 13TH TSP 14 30 05/94 RF0 Bobbin ADI 4.06 11TH TSP

+15.65 F/L 05/94 RF0 C/L Special Int VOL 0.74 11TH TSP

+16.36 11TH TSP 14 51 05/94 RF0 Bobbin No!

0.39 4TH TSP

+8.03 F/L 05/94 RF0 Bobbin ODI 18 0.56 4TH TSP

+7.40 F/L 05/94 RF0 Bobbin 001 24 0.70 4TH TSP

+8.96 F/L 14 69 05/94 RF0 Bobbin No!

0.38 10TH TSP

+23.63 F/L 05/94 RF0 Bobbin 001 13 0.70 BTH TSP

-5.13 F/L 05/94 RF0 Bobbin DDI 15 1.00 6TH TSP

+39.90 F/L 05/94 RF0 Bobbin 001 16 1.37 7TH TSP

+29.04 F/L 05/94 RF0 Bobbin 001 22 1.91 7TH TSP

+27.44 F/L 14 74 05/94 RF0 Bobbin 001 8

1.17 10TH TSP

+38.12 F/L 14 108 05/94 RF0 Bobbin ADI 3.88 13TH TSP

+3.02 F/L 05/94 RF0 C/L Special Int VOL 0.54 13TH TSP

+1.19 13TH TSP 05/94 RF0 C/L Special Int VOL 0.71 13TH TSP

+2.59 13TH TSP 14 111 05/94 RFC Bobbin 001 5

0.83 11TH TSP

+29.55 F/L 15 6 05/94 RF0 Bobbin 001 2

2.44 71H TSP

+24.47 F/L 05/94 RF0 Bobbin 001 5

1.70 17TH TSP

+13.05 F/L 15 8 05/94 RF0 Bobbin 001 4

1.45 7TH TSP

+10.94 F/L 05/94 RF0 Bobbin 001 7

3.33 71H TSP

+11.99 F/L 05/94 RF0 Bobbin 001 3

1.51 10TH TSP

+16.63 F/L 15 10 05/94 RF0 Bobbin 001 4

1.15 12TH TSP

+10.70 F/L 15 11 05/94 RF0 Bobbin DDI 6

0.73 12TH TSP

+10.79 F/L 15 2G 05/94 RF0 Bobbin No!

0.68 16TH TSP

+3.44 F/L 03/94 RF0 C/L Special Int VOL 0.31 16TH TSP

+3.77 16TH TSP 15 23 05/94 RF0 Bobbin ADI 2.84 11TH TSP

+36.07 F/L 05,94 RF0 C/L Special Int VOL 0.59 10TH TSP

-8.32 10TH TSP 15 50 03/94 RF0 Bobbin DDI 2

0.88 3RD TSP

+4.43 F/L 15 72 05/94 RF0 Bobbin ADI 5.56 12TH TSP

+30.51 F/L 05/94 RF0 C/L Special Int VOL 0.89 11TH TSP

-12. 73 11TH TSP 15 98 05/94 RF0 Bobbin 001 12 1.12 12TH TSP

-3.92 F/L c

15 99 05/94 RF0 Bobbin ADI 6.15 4AVB

-9.17 F/L 05/94 RF0 Bobbin ADI 11.81 1AVB

+7.02 F/L 05/94 RF0 Bobbin ADI 3.83 11TH TSP

+16.72 F/L 05/94 RF0 Bobbin ADI 6.00 11TH TSP

+20.79 F/L 05/94 RF0 Bobbin 001 12 2.06 STH TSP

+15.11 F/L 05/94 RF0 U-Bend VOL 0.68 4AVB

-9.67 9TH TSP 05/94 RF0 U Bend VOL 1.47 1AVB

+7.02 9TH TSP 05/94 RF0 Bobbin 001 32 1.44 11TH TSP

+28.43 F/L 05/94 RF0 H/L Special Int VOL 0.99 STH TSP

+15.24 STH TSP 05/94 RF0 C/L Special Int VOL 0.55 11TH TSP

+41.39 10TH TSP 05/94 RF0 C/L Special Int VOL 0.64 11TH TSP

+16.72 10TH TSP 05/94 RF0 C/L Special Int VOL 0.99 11TH TSP

+20.79

  • 0TH TSP 05/94 RF0 C/L Specist Int VOL 1.11 11TH TSP

+28.43 10TH TSP 15 104 05/94 RF0 Bobbin No!

2.58 12TH TSP

+35.08 F/L 05/94 RF0 C/L Special Int VOL 2.0211TH TSP 8.20 11TH TSP 15 111 05/94 RF0 Bobbin 001 16 0.59 10TH TSP

+32.51 F/L 16 4 05/94 RF0 Bobbin 001 3

0.77 77H TSP

+0.70 F/L 05/94 RF0 H/L Special Int VOL 0.93 7TH TSP

+0.74 7TH TSP 16 29 05/94 RF0 Bobbin ADI 3.98 12TH TSP

+20.99 F/L 05/94 RF0 C/L Special Int VOL 0.67 12TH TSP

+20.47 12TH TSP 16 '42 05/94 RF0 Bobbin 001 14 0.63 10TH TSP

+33.40 F/L 16 43 05/94 RF0 Bobbin DDI 17 1.19 TTS-HL

+3.10 F/L 16 44 05/94 RF0 Bobbin 001 5

4.40 1ST TSP

-6.31 F/L 16 46 05/94 RF0 Bobbin Nol 0.36 3RD TSP

-6.45 F/L 05/94 RF0 Bobbin 001 14 0.57 3RD TSP

-4.79 F/L 16 50 05/94 RF0 Bobbin.

001 3

2.07 1ST TSP

+15.77 F/L 05/94 RF0 H/L Special Int VOL 0.59 1ST TSP

+14.88 1ST TSP 16 52 05/94 RF0 Bobbin 001 1

2.17 TTS HL

+3.83 F/L 16 62 05/94 RF0 Bobbin ADI 3.05 6TH TSP

+34.93 F/L 05/94 RF0 Bobbin ADI 1.09 19TH TSP

-4.42 F/L 05/94 RF0 H/L Special Int VOL 0.82 7TH TSP 8.37 71H TSP J

l BWNS TUBAN II (Version 2.0) 06/17/1994 06:29:03 Catewba Nuclear Station - Unit Two S/G C 05/94 RF0 seee.e**********************

Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U Bend Pige 8 of 27 S/G C ATTACHMENT #3 ]NDICATIONS OF IMifk ECTIONS T

RDW COL DUTAGE TEST TYPE IND JTS VOLTS LOCATION EXTENT 1 16 63 05/94 RF0 Bobbin 001 13 1.11 19TH TSP

-4.47 F/L 16 65 05/94 RF0 Bobbin ADI 2.86 10TH TSP

+31.05 F/L 05/94 RF0 Bobbin NOI 0.82 10TH TSP

+29.55 F/L 05/94 AFO $'6ron '

001 14 0.81 7TH TSP

+29.44 F/L 05/94 RF0 Bo6 bin 001 25 0.46 BTH TSP

-12.14 F/L 16 67 05/94 RF0 Bobbin 001 22 1.29 9TH TSP

-2.71 F/L 16 71 05/94 RF0 Bobbin 001 34 0.92 BTH TSP 9.76 F/L 05/94 RF0 H/L Special Int VOL 2.53 BTH TSP

-9.18 BTH TSP 1/ 77 05/94 RF0 Bobbin ADI 1.49 10TH TSP

+14.36 F/L 10 78 05/94 RF0 Bobbin NQ1 0.52 10TH TSP

+32.19 F/L 05/94 RF0 Bobbin 001 3

2.06 7TH TSP

+37.69 F/L 05/94 RF0 Bobbin 001 6

2.75 7TH TSP

+27.81 F/L 05/94 RF0 Bobbin 001 8

0.64 7TH TSP

+19.51 F/L 05/94 RF0 Bobbin 001 26 0.26 71H TSP

+32.13 F/L 05/94 RF0 Bobbin 001 6

1.83 10TH TSP

+38.16 F/L 05/94 RF0 Bobbin 001 9

1.07 10TH TSP

+33.37 F/L 05/94 RF0 Bobbin 001 13 1.33 17TH TSP

-8.67 F/L 05/94 RF0 Bobbin 001 20 0.32 10TH TSP

+32.79 F/L 05/94 RF0 Bobbin 001 23 1.15 12TH TSP

+16.35 F/L 05/94 RF0 C/L Special Int VOL 0.75 9TH TSP

-14.51 9TH TSP 05/94 RF0 H/L Special Int VOL 0.35 BTH TSP

-24.57 BTH TSP 05/94 RF0 H/L Special Int VOL 0.69 STH TSP

-18.12 BTH TSP 05/94 RF0 H/L Special Int VOL 2.08 8TH TSP

-4.41 8TH TSP 05/94 RF0 H/L Special Int VOL 2.32 8TH TSP

-5.54 8TH 100 05/94 RF0 H/L Special Int VOL 3.29 BTH TSP 14.34 BTH TSP 05/94 RF0 H/L Special Int VOL 4.58 BTH TSP

-16.97 BTH TSP

{

05/94 RF0 C/L Special Int VOL 0.28 17TH TSP

-9.17 17TH TSP 05/94 RF0 C/L Special Int VOL 0.87 12TH TSP

+16.35 12TH TSP 16 85 05/94 RF0 Bobbin DDI 35 0.81 STH TSP

+5.22 F/L OS/94 RF0 H/L Special Int VOL 1.11 STH TSP

+5.41 STH TSP 16 91 05/94 RF0 Bobbin DDI 30 0.75 71H TSP

+9.33 F/L 05/94 RF0 H/L Special Int VOL 0.73 7TH TSP

+9.88 7TH TSP 16 98 05/94 RF0 Bobbin NQI 0.91 1ST TSP

+26.13 F/L 05/94 RF0 Bobbin NQ1 1.07 2ND TSP

+3.25 F/L 1

05/94 RF0 Bobbin NQI 1.31 4TH TSP

+13.88 F/L 05/94 RF0 H/L Special Int VOL 0.29 2ND TSP

-1.51 2k0 TSP 05/94 RF0 H/L Special Int VOL 0.32 2ND TSP

+3.75 2ND TSP 05/94 RF0 H/L Special Int VOL 0.34 2ND TSP

+3.08 2ND TSP 05/94 RF0 H/L Special Int VOL 0.42 2ND TSP

-2.68 2ND TSP 05/94 RF0 H/L Special Int VOL 0.58 4TH TSP

+16.29 4TH TSP 05/94 RF0 H/L Special Int VOL 0.64 2ND TSP

+1.15 2ND TSP 05/94 RFC H/L Special Int VOL 0.66 2ND TSP

+2.35 2ND TSP 05/94 RF0 H/L Special Int VOL 0.68 4TH TSP

+14.36 4TH TSP 05/94 RF0 H/L Special Int VOL 0,69 4TH TSP

+6.00 4TH TSP 05/94 RF0 H/L Special Int VOL 0.74 4TH TSP

+15.03 4TH TSP 05/94 RF0 H/L Special Int VOL 0.80 4TH TSP

+15.59 4TH TSP i

05/94 RF0 H/L Special Int VOL 0.85 4TH TSP

+ 13. 73 4TH TSP l

05/94 RF0 H/L Special Int VOL 1.36 2ND TSP

+7.67 2ND TSP 16 105 05/94 RF0 Bobbin 001 6

0.60 97H TSP

-2.05 F/L 16 107 05/94 RF0 Bobbin 001 22 0.56 6TH TSP

+41.10 F/L 05/94 RF0 H/L Special Int VOL 0.51 7TH TSP

-2.81 77H TSP 17 11 05/94 RF0 Bobbin 001 4

0.99 BTH TSP

-1.22 F/L 17 14 05/94 RF0 Bobbin NQI 0.48 12TH TSP

+32.60 F/L 05/94 RF0 Bobbin NQI 0.83 13TH TSP

+19.54 F/L 05/94 RF0 Bobbin 001 11 3.01 10TH TSP

+11.78 F/L 17 21 05/94 RF0 Bobbin 001 5

1.06 12TH TSP

+36.09 F/L 17 32 05/94 RF0 Bobbin DDI 4

1.09 18TH TSP

+16.24 F/L 17 36 05/94 RF0 Bobbin ADI 1.99 12TH TSP

+35.83 F/L 17 38 05/94 RF0 Bobbin ODI 16 0.71 17TH TSP

+8.32 F/L 17 69 05/94 RFO Bobbin 001 5

0.88 10TH TSP

+27.60 F/L 17 73 05/94 RF0 Bobbin NCI 0.50 10TH TSP

+12.54 F/L 05/94 RF0 C/L Special Int VOL 0.42 10TH TSP

+11.20 10TH TSP 17 79 05/94 RF0 Bobbin NQ!

0.49 4TH TSP

+37.99 F/L 05/94 RF0 H/L Special Int VOL 0.50 STH TSP

-5.31 STH TSP 17 81 05/94 RF0 Bobbin No!

0.85 4TH TSP

+1.54 F/L 05/94 RF0 H/L Special Int VOL 1.29 4TH TSP

+1.54 4TH TSP

BWNS TUBAN II (Version 2.0) 06/17/1994 06:29:03 eseeen.e e******************

Cat, a Nuclear Station - Unit Two S/G C e.............**......******

05/94 RF0 Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U Bend Page 9 of 27 S/G C - ATTACHMENT #3 INDICATIONS OF IMPERFECTIONS ROW COL QUTAGE TEST TYPE IND %TW VOLTS LOCATION EXTENT 1 17 88 05/94 RF0 Bobbin 001 30 1.13 15TH TSP

+15.78 F/L 17 89 05/94 RF0 Bobbin 001 34 2.63 2ND TSP

-1.85 F/L 05/94 RF0 H/L Special Int VOL 2.39 2ND TSP

-1.61 2ND TSP 17 91 05/94 RF0 Bobbin NQI 1.98 17TH TSP

-6.17 F/L 05/94 RF0 C/L Special Int VOL 1.03 18TH TSP

+11.99 17TH TSP 1710105/94 RF0 Bobbin NQI 0.91 4TH TSP

+16.13 F/L 05/94 RF0 H/L Specia! Int VOL 0.92 4TH TSP

+16.35 4TH TSP 18 29 05/94 RF0 Bobbin 001 8

0.98 11TH TSP

+16.76 F/L 05/94 RF0 Bobbin 001 30 2.34 19TH TSP

-1.26 F/L 05/94 RF0 C/L Special Int VOL 1.03 19TH TSP 1.22 19TH TSP 18 36 05/94 RF0 Bobbin ADI 2.15 4TH TSP

-4.39 F/L 05/94 RF0 H/L Special Int VOL 0.26 4TH TSP

-6.22 4TH TSP 18 45 05/94 RF0 Bobbin 001 8

3.82 TTS-HL

+2.25 F/L 05/94 RF0 H/L Tubesheet VOL 0.26 TTS-HL

+0.00 TTS HL P'f94 RF0 H/L Special Int VOL 0.67 TTS HL 0.03 TTS-HL 0..e4 RF0 H/L Special Int VOL 1.36 TTS-HL

+3.34 TTS-HL 18 63 05/94 RF0 Bobbin PSI 32 0.44 12TH TSP

+2.75 F/L 05/94 RF0 Bobbin ODI 38 0.58 12TH TSP

-9.43 F/L 18 76 05/94 RF0 Bobbin ODI 21 0.76 10TH TSP

+4.06 F/L 18 78 05/94 RF0 Bobbin 001 15 0.80 13TH TSP

+23.32 F/L 05/94 RF0 Bobbin DDI 34 0.65 13TH TSP

+21.80 F/L 05/94 RF0 C/L Special Int VOL 0.37 131H TSP

+24. 84 13TH TSP 05/94 RFO C/L Special Int VOL 0.44 13TH TSP

+23.32 13TH TSP 05/94 RF0 C/L Special Int VOL 0.63 13TH TSP

+21.80 13fH TSP 18 102 05/94 RF0 Bobbin 001 13 3.84 10TH TSP

+26.24 F/L 18 109 05/94 RF0 Bobbin ODI 19 1.84 7TH TSP

+24.24 F/L 18 110 05/94 RF0 Bobbin 001 22 0.77 10TH TSP

+26.84 F/L 19 6 05/94 RF0 Bobbin 001 19 0.4017TH TSP

+8.03 F/L 19 21 05/94 RF0 Bobbin ADI 1.20 10TH TSP

+27.93 to +31.64 F/L 19 25 05/94 RF0 Bobbin ODI 15 0.58 10TH TSP

-8.88 F/L 19 42 05/94 RF0 Bobbin ADI 11.54 4TH TSP

+0.68 F/L 05/94 RF0 Bobbin NO!

0.60 4TH TSP

+20.83 F/L 05/94 RF0 H/L Special Int VOL 0.49 4TH TSP

+20.53 4TH TSP 05/94 RF0 H/L Special Int VOL 0.97 4TH TSP

+0.86 4TH TSP 19 46 05/94 RF0 Bobbin NQ1 0.89 17TH TSP

+4.93 F/L 05/94 RF0 C/L Special Int VOL 0.52177H TSP

+6.02 17TH TSP 19 62 05/94 RF0 Bobbin 001 7

0.93 18TH TSP

+3.16 F/L 19 63 05/94 RF0 Bobbin NQI 0.88 14TH TSP

+3.71 F/L 05/94 RF0 C/L Special Int VOL 0.78 14TH TSP

+3.71 14TH TSP 19 64 05/94 RF0 Bobbin ODI 11 3.19 4TH TSP

+39.66 F/L 19 72 05/94 RF0 Bcbbin ADI 3.52 17TH TSP

+6.40 F/L 05/94 RF0 Bobbin NQI 0.31 11TH TSP

-11.12 F/L 05/94 RF0 C/L Special Int VOL 0.19 17TH TSP

+6.40 17TH TSP 05/b RF1 5/L Special Int vnL 0.29 11TH TSP

-11.16 11TH TSP 19 80 05/9a RF0 Lobbin 001 8

2.08 10TH ISK

+40.'1 F/L 05/94 RF0 Bobbit.

001 15 0.85 10TH TSP

+24.18 F/L 19 fy 05/94 RF0 Bobbin NQI 0.91 11TH TSP

+29.41 F /t.

05/06 RF0 C/L Special Int VOL 0.93 10TH TSP

-13.74 10TH TSP 19 93 05/94 RF0 Bobbin NQI 0.30 ?TH TSP

+24.95 F/L 05/94 RF0 Bobbin NQI 0.38 7TH TSP

+25.14 F/L 19 102 05/94 RF0 Bobbin 001 25 0.63 3RD TSP

+21.75 F/L 19 107 05/94 RF0 Bobbin 001 16 2.07 7TH TSP

+28.10 F/L 05/94 RF0 H/L Special Int VOL 1.35 BTH TSP

-14.05 STH TSP 05/94 RF0 H/L Special Int VOL 1.55 8TH TSP

-15.15 BTH TSP 05/94 RF0 H/L Specict Int VOL 4.10 BiH TSF

-14.04 8TH TSP 19 108 05/94 RF0 Bobbin DDI 8

0.66 3RD TSP

+20.36 F/L 05/94 RF0 Bobbin 001 18 0.70 9TH TSP

-1.39 F/L 05/94 RF0 Bobbin 001 19 0.86 BTH TSP

-2.04 F/L 20 15 05/94 RF0 Bobbin 001 12 1.19 14TH TSP

+7.79 F/L 20 29 05/94 RF0 Bobbin 001 18 2.77 10TH TSP

+7.63 F/L 20 43 05/94 RF0 Bobbin 001 37 0.65 11TH TSP

+34.14 F/L 05/94 RF0 C/L Special Int VOL 1.02 10TH TSP

-12.39 10TH TSP 20 47 05/94 RF0 Bobbin 001 14 2.28 11TH TSP

+27.66 F/L 20 58 05/94 RF0 Bobbin ODI 9

0.50 2ND TSP

+22.69 F/L 20 59 05/94 RF0 Bobbin 001 36 0.72 91H TSP

-3.05 F/L 20 60 05/94 RF0 Bobbin NQ1 0.30 9fH tsp

-0.22 F/L

BWNS TUBAN 11 (Version 2.0) 06/17/1994 06:29:03 Catawba Nuclear Station - Unit Two eeeeeeee+.******************

S/G C 05/94 RF0 Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U-Bend Page 10 of 27 S/G C - ATTACHMENT #3 INDICATIONS OF IMPERFECTIONS ROW COL DUTAGE TEST TYPE IND %TW VOLTS LOCATION EXTENT 1 20 61 05/94 RFO Bobbin ODI 36 0.34 9TH TSP

-0.82 F/L 05/94 RFO Bobbin ODI 11 0.43 10TH TSP

+8.81 F/L 20 62 05/94 RF0 Bobbin 001 6

0.81 3RD TSP

+7.34 F/L 05/94 RF0 Bobbin 001 26 1.22 9TH TSP

-1.63 F/L 20 64 05/94 RF0 Bobbin 001 21 1.21 7TH TSP

+2.86 F/L 20 65 05/94 RF0 Bobbin DDI 5

1.71 10TH TSP

+23.42 F/L 20 67 05/94 RF0 Bobbin 001 1

1.30 10TH TSP

+32.67 F/L 20 74 05/94 RF0 Bobbin 001 25 2.27 18TH TSP

+10.60 F/L 20 82 05/94 RF0 Bobbin ADI 5.08 STH TSP

+14.03 F/L 05/94 RF0 H/L Special Int VOL 0.88 STH TSP

+14.42 STH TSP 20 89 05/94 RF0 Bobbin ADI 2.41 77H TSP

+28.72 F/L 05/94 RF0 Bobbin 001 32 0.75 7TH TSP

+27.85 F/L 05/94 RF0 Bobbin 001 10 2.06 16TH TSP

-2.45 F/L 05/94 RF0 H/L Special Int VOL 0.52 BTH TSP

-14.02 BTH TSP 20 93 05/94 RF0 bobbin NQi 0.44 STH TSP

+4.36 F/L 20 100 05/94 RF0 Bobbin 001 2

1.41 15fH TSP

-7.78 F/L 20 103 05/94 RF0 Bobbin 001 11 0.92 12TH TSP

+17.18 F/L 21 14 05/94 RF0 Bobbin 001 11 0.98 15TH TSP

+11.68 F/L 21 21 05/94 RF0 Bobbin 001 17 0.70 11TH TSP

+20.22 F/L 21 24 05/94 RFO Bobbin 001 13 3.08 12TH TSP

+40.94 F/L 21 46 05/94 RF0 Bobbin 001 5

1.47 4TH TSP

<*;.06 F/L 05/94 RF0 Bobbin DDI 8

1.69 4TH TSP

+19.24 F/L 05/94 RF0 H/L Special Int VOL 0.35 4TH TSP

+19.36 4TH TSP 05/94 RF0 H/L Special Int VOL 1.55 4TH TSP

+25.02 4TH TSP 21 47 05/94 RF0 Bobbin No!

0.60 1DTH TSP

+33.61 F/L 05/94 RF0 C/L Special Int VOL 1.29 9TH TSP

-15.01 9TH TSP 21 54 05/94 RF0 Bobbin 001 15 0.91 12TH TSP

+19.00 F/L 21 58 05/94 RF0 Bobbin ODI 19 3.34 4TH TSP

+5.01 F/L 05/94 RF0 H/L Speclat Int VOL 1.13 4TH TSP

+5.37 4TH TSP 21 64 05/94 RF0 Bobbin DDI 1.21 7TH TSP

+ 7. 32 F/L 05/94 RF0 Bobbin 001 23 0.60 4TH TSP

+31.26 F/L 21 66 05/94 RF0 Bobbin 001 35 0.39 7TH TSP

+27.18 F/L 05/94 RF0 Bobbin 001 37 0.48 TTH TSP

+23.42 F/L 21 67 05/94 RF0 Bobbin ADI 3.03 STH TSP

+6.46 F/L 05/94 RF0 N/L Special Int VOL 0.68 STH TSP

+ 7. 08 STH TSP 21 70 05/94 RF0 Bobbin 001 28 0.71 7TH TSP

+7.82 F/L 05/94 RF0 Bobbin 001 4

3.0713TH TSP

+10.94 F/L 21 73 05/94 RF0 Bobbin 001 4

1.23 6TH TSP

+25.66 F/L 21 80 05/94 RF0 Bobbin ODI 13 1.32 14TH TSP

-7.98 F/L 21 81 05/94 RF0 Bobbin ADI 5.59 11TH TSP

-4.36 F/!

05/94 RF0 Bobbin ADI 6.01 11TH TSP 1.36 F/L 05/94 RF0 C/L Special Int VOL 0.86 11TH TSP

+3.95 11Ti TSP 05/94 RF0 C/L Special Int VOL 1.05 11TH TSP

-4.36 11T1 TSP 05/94 RF0 C/L Special Int VOL 1.16 11TH TSP

-1.36 11Tu TSP 21 95 05/94 RF0 Bobbin ADI 4.51 1ST TSP

+5.83 F/L 05/94 RF0 H/L Special Int VOL 0.42 1ST TSP

+5.92 1ST VSP 21 98 05/94 RF0 Bobbin No!

2.39 7TH TSP

+26.09 F/L 05/94 RF0 H/L Special Int VOL 0.77 BTH TSP

-16.52 8TH TSP 21 100 05/94 RF0 Bobbin 001 14 2.76 12TH TSP

+16.18 F/L 21 102 05/94 RF0 Bobbin 001 2

0.88 1ST TSP

+4.65 F/L 21 109 05/94 RFO Bobbin 001 2

1.00 9TH TSP

-7.48 F/L 05/94 RFO Bobbin 001 3

0.73 9TH TSP

-8.66 F/L 22 17 05/94 RFO Bobbin DDI 29 2.89 13TH TSP

+1.89 F/L 05/94 RF0 C/L Spectat Int VOL 1.82 13TH TSP

+2.18 13TH TSP 22 22 05/94 RF0 Bobbin 001 4

1.17 TTS HL

+2.71 F/L 05/94 RF0 Bobbin 001 5

1.58 11TH TSP

+30.51 F/L 22 38 05/94 RFO Bobbin 001 19 1.38 9TH TSP

+1.23 F/L 22 44 05/94 RFO Bobbin 001 5

1.82 13TH TSP

+37.10 F/L 22 71 05/94 RF0 Bobbin ADI 3.92 4TH TSP

+34.42 F/L 05/94 RF0 H/L Special Int VOL 0.64 STN TSP

-9.11 STH TSP 05/94 RF0 H/L Special Int VOL 0.84 STH TSP

-6.02 STH TSP 22 73 05/94 RF0 Bobbin NQI 0.48 4TH TSP

-0.05 F/L 05/94 RF0 H/L Special Int VOL 1.88 4TH TSP

-0.37 4TH TSP 22 74 05/94 RfD Bobbin ADI 5.42 13TH TSP

+2.37 1ST TSP 05/94 RF0 C/L Special Int VOL 0.3513TH TSP

+2.37 13TH TSP 22 75 05/94 RF0 Bobbin 001 16 0.9712TH TSP

+19.99 F/L 1

i l

1 1

BWNS TUBAN II (Version 2.0) 06/17/1994 06:29:03 i

Catawba Nuclear Station - Unit Two

  • e**************************

S/G C e....e**********************

05/94 RF0 Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U Bend Page 11 of 27 i

S/G C - ATTACHMENT #3 INDICATIONS OF IMPERFECTIONS ROW COL OUTACE TEST TYPE IND %TW VOLTS LOCATION EXTENT 1 22 77 05/94 RF0 Bobbin 001 16 0.63 10TH TSP

+40.66 F/L 22 81 05/94 RF0 Bobbin NOI 1.13 4TH TSP

+21.30 F/L 05/94 RF0 H/L Special Int VOL 0.91 STH TSP

-21.71 STH TSP 22 90 05/94 RF0 Bobbin 001 23 1.53 6TH TSP

+1.79 F/L 05/94 RF0 H/L Special Int VOL 1.36 6TH TSP

+1.79 6TH TSP 22 93 05/94 RF0 Bobbin 001 6

1.19 77H TSP

+38.57 F/L 05/94 RF0 Bobbin ODI 4

1.36 10TH TSP

+43.55 F/L 05/9'. RF0 Bobbin 001 20 0.28 10TH TSP

+42.32 F/L 22 100 05/94 RF0 Bobbin 001 20 1.66 15fH TSP

+13.57 F/L 22 107 05/94 RF0 Bobbin 001 10 0.76 71H TSP

+21.40 F/L 23 6 05/94 RF0 Bobbin ODI 9

1.10 STH TSP

+15.51 F/L 05/94 RF0 Bobbin 001 13 0.63 8TH TSP

+0.70 F/L 05/94 RF0 Bobbin ODI 19 1.11 BTH TSP

+6.73 F/L 05/94 RF0 Bobbin ODI 12 0.27 14TH TSP

+6.13 F/L 05/94 RF0 Bobbin ODI 21 1.74 12TH TSP

+22.88 F/L 05/94 RF0 Bobbin ODI 38 0.37 14TH TSP

+9.84 F/L 23 is 05/94 RF0 Bobbin 001 7

1.38 11TH TSP

+26.04 F/L 23 33 05/94 RF0 Bobbin ODI 3

1.70 7TH TSP

+16.67 F/L 23 34 05/94 RF0 Bobbin ADI 2.48 10TH TSP

+40.16 F/L 05/94 RF0 Bobbin ODI 6

1.25 10TH TSP

+38.72 F/L 05/94 RF0 Bobbin 001 13 0.41 10TH TSP

+43.96 F/L 05/94 RF0 C/L Special Int VOL 1.99 91H TSP

-9.33 9TH TSP 05/94 RF0 C/L Special Int VOL 2.18 91H TSP

-7.94 97H TSP 23 35 05/94 RF0 Bobbin 001 15 1.89 2ND TSP

+7.22 F/L 23 37 05/94 RF0 Bobbin ADI B.15 18TH TSP

+10.35 F/L 05/94 RF0 C/L Special Int VOL 1.06 18TH TSP

+11.67 18TH TSP 05/94 RF0 C/L Special Int VOL 1.18 18TH TSP

+11.97 1BTH TSP 05/94 RF0 C/L Special Int VOL 1.75 181H TSP

+4.31 187H TSP 23 38 05/94 RF0 Bobbin ODI 4

1.19 10TH TSP

+15.41 F/L 23 73 05/94 RF0 Bobbin ODI 10 1.09 2ND TSP

+ 30. 73 F/L 23 76 05/94 RF0 Bobbin No!

0.41 10TH TSP

+33.22 F/L 05/94 RF0 Bobbin 001 4

1.55 9TH TSP

-9.82 F/L 23 77 05/94 RF0 Bobbin ODI B

1.05 9TH TSP

-4.31 F/L 23 83 05/94 RF0 Bobbin No!

0.58 12TH ISP

+11.28 F/L 05/94 RF0 C/L Special Int VOL 0.17 12TH TSP

+6.40 12TH TSP 05/94 RF0 C/L Special Int VOL 0.28 12TH TSP

+7.71 12TH TSP 23 86 05/94 RF0 Bobbin ADI 4.68 11TH TSP

+6.06 F/L 05/94 RF0 C/L Special Int VOL 0.90 11TH TSP

+6.06 11TH TSP 23 87 05/94 RF0 Bobbin NQI 0.40 16TH TSP

+12.93 F/L 23 90 05/94 RF0 Bobbin NOI 0.40 71H TSP

+26.20 F/L 05/94 RF0 H/L Special Int VOL 0.54 77H TSP

+26.95 77H TSP 23 91 05/94 RF0 Bobbin ADI 1.54 12TH TSP

+8.13 F/L 05/94 RF0 Bobbin ADI 1.60 10TH TSP

+32.90 F/L 05/94 RF0 C/L Special Int VOL 0.34 97H TSP

-11.17 97H TSP 05/94 RTO C/L Special Int VOL 0.25 12TH TSP

+8.13 12TH TSP 23 93 05/94 RF0 Bobbin ODI 10 1.03 7TH TSP

+14.09 F/L 05/94 RF0 H/L Special Int VOL 1.42 7TH TSP

+14.27 7TH TSP 23 98 05/94 RF0 Bobbin ADI 3.51 77H TSP

+29.42 F/L 05/94 RF0 H/L Special Int VOL 0.43 BTH TSP

-13.47 BTH TSP 23 102 05/94 RF0 Bobbin ODI 14 1.74 12TH TSP

+7.01 F/L 24 8 05/94 RF0 Bobbin ADI 5.98 STH TSP

+4.50 F/L 05/94 RF0 Bobbin No!

0.29 BTH TSP

+0.81 F/L l

05/94 RF0 Bobbin 001 4

0.94 71H TSP

+8.09 F/L 05/94 RF0 Bobbin ODI 7

0.91 3RD TSP

+0.72 F/L j

05/94 RF0 H/L Special Int VOL 0.65 STH TSP

+4.89 STH TSP 24 27 05/94 RF0 Bobbin 001 29 0.74 6TH 1SP

+26.14 F/L i

24 29 05/94 RTO Bobbin 001 2

1.26 97H TSP

-11.32 F/L 05/94 RF0 Bobbin ODI 6

0.63 9TH TSP

-10.78 F/L 24 31 05/94 RF0 Bobbin ADI 3.45 10TH TSP

+7.82 F/L 05/94 RF0 C/L Special Int VOL 1.28 10TH TSP

+7.64 10TH TSP 05/94 RTO C/L Special int VOL 2.81 10TH TSP

+8.95 10TH TSP 24 32 05/94 RF0 Bobbin ADI 1.04 TTS-HL

+3.67 F/L 24 35 05/94 RF0 Bobbin 001 1

1.10 15fH TSP

+ 7.39 F/L 24 37 05/94 RF0 Bobbin 001 38 0.45 BTH TSP

-0.59 F/L 24 39 05/94 RF0 Bobbin Nol 0.37 8TH TSP 0.54 F/L 05/94 RF0 Bobbin 001 25 0.45 97H TSP

-0.74 F/L

BWNS TUBAN 11 (Version 2.0) 06/17/1994 06:29:03 Catawba Nuclear Station - Unit Two eeeeeeee.................***

S/G C

    • e.************************

05/94 RF0 ees.************************

Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U-Bend Page 12 of 27 S/G C - ATTACHMENT #3 INDICATIONS OF IMPERFECTIONS ROW COL 00 TACE TEST TYPE IND %TW VOLTS LOCATION EXTENT 1 24 44 05/94 RF0 Bobbin 001 5

2.02 9TH TSP

-0.72 F/l 24 60 05/94 RF0 Bobbin NQI 0.41 10TH TSP

+32.96 F/L 05/94 RF0 Bobbin 001 9

0.85 10TH TSP

+34.02 F/L 05/94 RF0 Bobbin 001 15 0.80 10TH 1SP

+39.65 F/L 05/94 RF0 Bobbin ODI 25 0.27 10TH TSP

+38.13 F/L 05/94 RF0 Bobbin DDI 31 0.58 10TH TSP

+35.80 F/L 24 61 05/94 RF0 Bobbin 001 16 0.98 17TH TSP

+11.46 F/L 24 64 05/94 RF0 Bobbin No!

0.57 9TH TSP

+0.59 F/L 05/94 RF0 Bobbin 001 2

1.20 11TH TSP

+24.26 F/L 05/94 RF0 Bobbin 001 4

0.79 13fH TSP

-3.70 F/L 24 65 05/94 RF0 Bobbin NQI 1.39 18TH TSP

+3.99 F/L 05/94 RF0 Bobbin ODI 31 0.75 10TH TSP

+3.97 F/L 05/94 RF0 C/L Special Int VOL 1.14 18TH TSP

+3.94 18TH TSP 24 66 05/94 RF0 Bobbin ADI 2.53 17TH TSP

+12.33 F/L l

05/94 RF0 Bobbin N01 0.56 1;TH TSP

+2,04 F/L 05/94 RF0 C/L Special Int VOL 0.'"

iH TSP

+2.04 15TH TSP 05/94 RF0 C/L Special Int VOL 0

17TH TSP

+'2.33 17TH TSP 24 67 05/94 RF0 Bobbin ADI E ) 12TH TSP 49.12 F/L L

05/94 RF0 C/L Special Int VOL

.3 12TH TSP

+12.63 12TH TSP l

05/94 RF0 C/L Special Int VOL s.44 12TH TSP

+9.12 12TH TSP 24 71 05/94 RF0 Bobbin ADI 1.25 18FH TSP

-7.40 F/L 24 72 05/94 RF0 Bobbin DDI 12 1.35 10TH TSP

+15.92 F/L 24 75 05/94 RF0 Bobbin ODI 21 0.63 TTH TSP

+29.77 F/L 05/94 RF0 Bobbin DDI 24 0.73 10TH TSP

+19.27 F/L 24 80 05/94 RF0 Bobbin DDI 11 1.45 3RD TSP

+6.83 F/L 24 86 05/94 RF0 Bobbin ADI 2.74 197H TSP

+3.92 F/L 05/94 RF0 Bobbin 001 6

1.17 BTH TSP

-1.48 F/L 05/94 RF0 Bobbin 001 13 0.51 10TH iSP

+43.20 F/L 05/94 RF0 C/L Special Int VOL 0.64 19TH TSP

+3.27 19TH TSP 24 87 05/94 RF0 Bobbin ADI 2.27 10TH TSP

+19.89 F/L 05/94 RF0 C/L Special Int VOL 0.65 10TH TSP

+19.64 10TH TSP 24 91 05/94 RF0 Bobbin 001 1

1.97 71H TSP

+2.28 F/L 24 97 05/94 RF0 Bobbin 001 8

1.08 7TH TSP

+31.66 F/L 05/94 RF0 Bobbin 001 10 0.98 7th TSP

+12.15 F/L 05/94 RF0 Bobbin 001 33 0.34 6TH TSP

+33.38 F/L 05/94 RF0 Bobbin 001 37 0.25 6TH TSP

+38.38 F/L 05/94 RF0 H/L Special Int VOL 0.56 7TH TSP

+13.02 7TH TSP 05/94 RF0 H/L Special Int VOL 0.75 7TH TSP

-4.14 TTH TSP 05/94 RF0 H/L Special Int VOL 0.82 7TH TSP

+7.60 7TH TSP 05/94 RF0 H/L Special Int VOL 1.00 7TH TSP

+32.81 7TH TSP 24 103 05/94 RF0 H/L Tubesheet VOL 1.29 TTS HL

+0.00 TTS-HL 24 106 05/94 RF0 Bobbin NQI 1.60 BTH TSP

-2.47 F/L 05/94 RF0 Bobbin ADI 4.09 15fH TSP

+5.09 F/L 05/94 RF0 H/L Special Int VOL 0.44 BTH TSP

-2.41 BTH TSP 05/94 RF0 C/L Special Int VOL 0.57 15TH TSP

+5.09 15TH TSP 25 25 05/94 RF0 Bobbin ODI 9

0.68 7TH TSP

+41.68 F/L 05/94 RF0 Bobbin DDI 15 1.60 7TH TSP

+40.57 F/L 25 29 05/94 RF0 Sobbin ODI 7

0.63 2ND TSP

+5.31 F/L 05/94 RF0 Bobbin 001 25 0.85 BTH TSP

-0.57 F/L 25 30 05/94 RF0 Bobbin 001 1

1.04 STH TSP

-3.87 F/L 05/94 RF0 Bobbin ODI 6

1.48 9TH TSP

-9.35 F/L 05/94 RF0 Bobbin ODI 35 0.96 8TH TSP

-5.11 F/L 25 39 05/94 RF0 Bobbin DDI 31 0.65 BTH TSP

-9.98 F/L 25 43 05/94 RF0 Bobbin NQI 0.71 16TH TSP

+6.79 F/L 05/94 RF0 C/L Special Int VOL 0.64 16TH TSn 48.61 16TH TSP 25 45 05/94 RF0 Bobbin NOI 1.96 7TH TSF

+15.35 F/L 05/94 RF0 H/L Special Int VOL 0.56 7TH TSP

+15.33 7TH TSP 25 50 05/94 RF0 Bobbin NQI 0.82 12TH TSP

+23.47 F/L 05/94 RF0 C/L Special Int VOL 0.40 12?" TSP

+23.47 12TH TSP 25 56 05/94 RF0 Bobbin 001 7

1.39 TTS-HL

+1.89 F/L 05/94 RF0 H/L Special Int VOL 0.53 TTS-HL

+1.85 TTS HL 25 64 05/94 RF0 Bobbin ADI 2.24 4TH TSP

+33.04 F/L 05/94 RF0 H/L Special Int VOL 1.38 STH TSP

-10.29 STH TSP 25 66 05/94 RF0 Bobbin ODI 12 0.88 7TH TSP

+18.02 F/L 05/94 RF0 H/L Special Int VOL 0.57 7TH TSP

+20.44 7TH TSP 05/94 RF0 H/L Spe;ial Int VOL 1.22 7TH TSP

+13.64 7TH TSP

e......sr.v a***************

BVN9 TUBAN !! (Version 2.0) 06/17/1994 06:'49:03 Catawba Nuclear Station - Unit Two

      • t************************

S/G C ee.************************

05/94 RF0

?6.........****************

Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U Bend Page 13 of 27 S/G C ATTACHMENT #3 INDICATIUNS OF IMPERFECTIONS ROW COL DUTAGE TEST TYPE IND %TW VOLTS LOCAT!ON EXTENT 1 05/94 RF0 H/L Special Int VOL 2.34 7TH TSP

+2.41 7TH TSP 25 75 05/94 RF0 Bobbin ODI 16 0.70 2ND TSP

+3's. 51 F/L 05/94 RF0 Bobbin 001 18 0.47 3RD TSP

+I4.02 F/L 05/94 RTO Bobbin 001 22 0.48 3RD TSP

+10.92 F/L 25 79 05/94 RF0 Bobbin NQi 1.16 1ST TSP

+25.61 F/L 05/04 RF0 Bobbin ODI 8

0.90 7TH TSS

+29.44 F/L 05/94 RF0 Bobbin 001 11 0.64 7TH '!!P

+31.64 F/L 05/94 RF0 Bobbin 001 21 0.99 15T4 TSP

+10.33 F/L 05/94 RfD H/L Speciel Int VOL 1.72 240 TSP

-2.60 2ND TSP 25 83 05/94 RF0 Bobbin No!

0.(5 4TH TSP

+ 14. 0.*

F/L 25 86 05/94 RF0 Bobbin 001 28 0.46 16TH TSP

+11.93 F/L 25 90 05/94 RF0 Dobbin No!

0.42 6TH TSP

+34.65 F/L 05/94 RF0 H/L Special Int VOL 0.48 77H TSP

- 8. 73 7TH TSP 25 92 05/94 RF0 Bobbin 001 1

1.58 15TH TSP

+4.90 F/L 25 97 05/94 RF0 Bobbin 001 4

0.77 16TH TSP

-1.56 F/L 26 8 05/94 RF0 Bobbin ADI 3.63 12TH TSP

+18.42 F/L 05/94 RF0 C/L Special Int VOL 0.51 12TH TSP

+18.42 12TH iSP 26 13 05/94 RF0 Bobbin 001 6

0.53 3RD TSP

+0.52 F/L 26 16 05/94 RF0 Bobbin 001 5

1.30 11TH TSP

+27.26 F/L 26 23 05/94 RF0 Bobbin 00 1 1

0.98 197H TSP

+4.55 F/L 05/94 RF0 Bobbin 001 17 0.84 197H TSP

+4.90 F/L 26 32 05/94 RF0 Bobbin 001 1

0.65 TTS-CL

+5.87 F/L 05/94 RF0 Bobbin 001 3

1.11 TTS-CL

+3.81 F/L 05/94 RFO C/L Special Int VOL 0.22 TTS-CL

+0.69 19TH TSP 05/94 RF0 C/L Special Int VOL 0.23 TTS-CL

+3.81 197H TSP 05/94 RF0 C/L Special Int VOL 0.23 TTS-CL

+5.87 197H TSP 26 40 05/94 JF0 Bobbin No!

0.71 3RD TSP

+27.70 F/L 05/94 RFC Bobbin 001 4

1.28 3RD TSP

+32.35 F/L 05/94 RF0 H/L Special Int vol 1.43 4TH TSP

-B.43 4TH TSP 26 44 05/94 9F0 Bobbin 001 4

2.44 10TH TSP

+37.99 F/L 05/94 RF0 C/L Special Int VOL 2.19 97H TSP

+7.89 9TH TSP 26 48 05/94 RF0 Bobbin 001 13 0.82 181H TSP

+2.40 F/L 05/94 RF0 C/L Special Int VOL 0.82 18TH TSP

+3.11 181H TSP 05/94 RF0 C/L Special Int VOL 0.92 18TH TSP

+2.92 18TH TSP 26 52 05/94 RFO Bobbin DDI 4

1.35 16TH TSP

-1.40 F/L 05/94 RF0 Bobbin 001 5

1.20 17TH TSP

+15.90 F/L 05/94 RF0 C/L Special Int VOL 0.29 16TH TSP

-1.40 16TH TSP 26 56 05/94 RF0 Bobbin ODI 3

2.50 13TH TSP

+14.71 F/L 26 59 05/94 RF0 Bobbin ADI 2.97 11TH TSP

+19.92 F/L 05/94 RF0 C/L Special Int VOL 0.45 11TH TSP

+19.78 11TH TSP 26 60 05/94 RF0 Bobbin 001 9

2.30 10TH TSP

+25.69 F/L 26 66 05/94 RF0 Bobbin Nol 1.35 3RD TSP

+21.04 F/L 05/94 kFO H/L Special Int VOL 1.23 4TH TSP

-15.14 4TH TSP E

26 72 05/94 Rio Bobbin NQ1 1.28 13TH TSP

+12.48 F/L 05/94 RF0 C/L Special Int V01 0.98 13fH TSP

+12.72 13fH TSP 26 75 05/94 RF0 Bobbin 001 7

1.85 77H TSP

+10.05 F/L 05/94 RF0 Bobbin 001 23 0.72 7TH TSP

+28.26 F/L 26 80 05/94 RF0 Bobbin ADI 5.26 13TH TSP

-2.38 F/L 05/94 RF0 C/L Special Int VOL 0.88 131H TSP

-2.02 13TH TSP 26 90 05/94 RF0 Bobbin 001 16 0.69 77H TSP

+33.26 F/L 26 97 05/94 RF0 Bobbin ADI 2.45 14TH TSP

-3.30 F/L 05/94 RF0 C/L Special Int VOL 0.63 14TH TSP

-5.05 14TH TSP 05/94 RF0 C/L Special Int VOL 0.69 14TH TSP

-4.03 14TH TSP 27 8 05/94 RF0 Bobbin WAR 11 0.63 3AVB

+0.00 F/L 05/94 RF0 U Bend VOL 2.25 37VB

+0.00 9TH TSP 27 9 05/94 RF0 Bobbin WAR 32 2.95 2AVB

+0.00 F/L 27 11 05/94 RF0 Bobbin 001 28 0.39 14TH TSP

+0.57 F/L 27 43 05/94 RF0 Bobbin 001 22 0.55 14TH TSP

+6.63 F/L 27 48 05/94 RF0 Bobbin 001 16 1.30 10TH TSP

+27.37 F/L 27 59 05/94 RF0 Bobbin NOI 1.05 4TH TSP

+25.87 F/L 05/94 RF0 H/L Special Int VOL 0.77 4TH TSP

+25.71 4TH TSP 27 60 05/94 RF0 Bobbin No!

1.02 77H TSP

+8.88 F/L 05/94 RF0 H/L Special Int VOL 1.40 71H TSP

+9.14 7TH TSP 27 79 05/94 RF0 Bobbin ADI 2.24 10TH TSP

+28.36 F/L 05/94 RF0 C/L Special Int VOL 0.36 10fH TSP

+27.64 10TH TSP 05/94 RFC C/L Special Int VOL 0.3810TH TSP

+25.40 10TH TSP

- ~

bWNS TUBAN II (Version 2.0) 06/17/1994 06:29:03 eee.************************

Catawba Nuclear Station

  • Unit Two e....ee.....................

S/G C eeeeeeee...........*********

05/94 RF0 eeee************************

Bobbin,C/L Special interest,H/L Special Interest,H/L Tubesheet,U Bend Page 14 of 27 S/G C - ATTACHMENT #3 INDICATIONS OF IMPERFECTIONS ROW COL DUTAGE TEST TYPE IND %TW VOLTS LOCATION EXTENT 1 05/94 RF0 C/L Special Int VOL 0.42 10TH TSP

+26.83 10TH TSP 05/94 RF0 C/L Special Int VOL 0.43 10TH TSP

+26.38 10TH TSP 05/94 RF0 C/L Special Int VOL 0.51 10TH TSP

+28.23 10TH TSP 27 80 05/94 RF0 Bobbin 001 23 0.76 6TH TSP

+31.58 F/L 05/94 RF0 H/L Special Int VOL 2.47 7TH TSP

-10.34 TTH TSP 27 83 05/94 Rio Bobbin NQI 0.72 14TH TSP

-2.56 F/L 6

05/94 RF0 C/L Special Int VOL 0.35 14TH TSP

-2.56 14TH TSP 27 84 05/94 RF0 Bobbin NQ1 0.42 13TH TSP

-10.99 F/L 27 91 05/94 RF0 Bobbin 001 19 0.77 71H TSP

+17.44 F/L 28 11 05/94 RF0 Bobbin ADI 5.64 4TH TSP

+41.12 F/L 05/94 RF0 Bobbin ADI 8.83 STH TSP

+36.05 F/L 05/94 RF0 Bobbin NQI 1.00 STH TSP

+24.08 F/L 05/94 RF0 Bobbin NQ1 1.03 STH TSP

+20.83 F/L 05/94 RF0 Bobbin 001 21 1.08 4TH TSP

+41.76 F/L 05/94 RF0 H/L Special Int VOL 0.47 STH TSP

+29.55 SlH TSP 05/94 RF0 H/L Special Int VOL 0.60 6TH TSP

-20.86 6TH TSP 05/94 RF0 H/L Special Int VOL 0.61 STH TSP

+16.62 STH TSP 05/94 RF0 H/L Special Int VOL 0.71 STH TSP

+21.70 STH TSP 05/94 RF0 H/L Special Int VOL 0.76 6TH TSP

-16.25 6TH TSP 05/94 RF0 H/L Special Int VOL 0.82 6TH TSP

-13.24 6TH TSP 05/94 RF0 H/L Special Int VOL 0.86 STH TSP

+6.16 STH TSP 05/94 RF0 N/t Special Int VOL 0.86 6TH TSP

-21.80 6TH TSP 05/94 RF0 H/L Special Int VOL 0.95 STH TSP

+17.70 STH TSP 05/94 RF0 H/L Special Int VOL 0.96 STH TSP

+26.33 STH TSP 05/94 RF0 H/L Special Int VOL 0.97 STH TSP

+ 23. 73 STH TSP 05/94 RF0 H/L Special Int VOL 1.03 51H TSP

+10.87 STN TSP 05/94 RF0 H/L Special Int VOL 1.14 STH TSP

+20.58 STH TSP 05/94 RF0 H/L Special Int VOL 1.24 6TH TSP

  • 18. 79 6TH TSP 05/94 RF0 H/L Special int VOL 1.37 6TH TSP

-6.53 6TH TSP 05/94 RF0 H/L Speelat Int VOL 1.97 STH TSP 1.62 STH TSP 28 29 05/94 RF0 Bobbin ODI 2

0.64 11TH TSP

+2.17 F/L 05/94 RF0 Bobbin 001 16 0.77 11TH TSP

+0.99 F/L 28 31 05/94 RF0 Bobbin 001 15 1.11 STH TSP

+26.86 F/L 28 33 05/94 RF0 Bobbin 001 10 2.64 BTH TSP

+18.85 F/L 28 34 05/94 RF0 Bobbin 001 19 0.82171H TSP

+4.53 F/L 28 36 05/94 RF0 Bobbin 001 15 0.80 10TH TSP

+34.03 F/L 28 39 05/94 RF0 Bobbin DDI 11 1.34 16TH TSP

+13.86 F/L 05/94 RF0 C/L Speclat Int VOL 0.62 151H TSP

-4.67 15TH TSP 28 48 05/94 RF0 Bobbin 001 11 0.7314TH TSP

+9.10 F/L 28 49 05/94 RF0 Bobbin 001 4

1.04 14TH TS9

+10.28 F/L 28 51 05/94 RF0 Bobbin 001 11 0.67 14TH TSP

+10.31 F/L 28 55 05/94 RF0 Bobbin 001 6

1.93 14TH TSP

+12.89 F/L 05/94 RF0 C/L Special Int VOL 0.91 13TH TSP

-6.44 13TH TSP 28 60 05/94 RF0 Bobbin NQI 2.84 17TH TSP

-1.56 F/L 05/94 RF0 C/L Special Int VOL 1.82 17TH TSP

-1.56 17TH TSP 28 62 05/94 RF0 Cobbin NQI 1.27 7TH TSP 4.02 F/L 05/94 RF0 H/L Special Int VOL 2.05 77H TSP 4.13 7TH TSP 28 66 05/94 RF0 Bobbin NGI 0.72 13TH TSP

+36.08 F/L 05/94 RF0 H/L Tubesheet VOL 0.92 TTS-HL 0.14 TTS HL 05/94 RF0 C/L Special Int VOL 0.43 12TH TSP

-6.54 12TH TSP 28 69 05/94 RF0 Bobbin ADI 6.08 12TH TSP

+5.10 to +15.75 F/L 05/94 RF0 C/L Specint Int VOL 0.64 12TH TSP

+5.50 to +11.61 12TH TSP 28 71 05/94 RF0 Bobbin N01 0.59 9TH TSP

-4.73 F/L 05/94 RF0 C/L Special Int VOL 0.99 97H TSP

-4.47 97H TSP 28 72 05/94 RF0 Bobbin 001 14 2.64 9TH TSP 6.12 F/L 28 75 05/94 RF0 Bobbin 001 5

1.71 7TH TSP

+15.48 F/L 05/94 RF0 Bobbin 001 7

1.22 BTH TSP

-9.42 F/L 05/94 RF0 Bobbin DDI 27 0.47 TTH TSP

+35.31 F/L 28 77 05/94 RF0 Bobbin NQl 1.16 16TH TSP

-B.34 F/L 05/94 RF0 Bobbin 001 21 1.06 91H TSP

-9.25 F/L 05/94 RF0 C/L Special Int VOL 0.40 16TH TSP

-8.37 16TH TSP 28 83 05/94 RF0 Bobbin ADI 13.56 12TH TSP

+19.30 to +25.78 F/L 05/94 RF0 C/L Special Int VOL 0.43 12TH TSP

+19.30 to +25.78 12TH TSP 28 90 05/94 RF0 Bobbin 001 12 1.10 7TH TSP

+11.08 F/L 28 91 05/94 RF0 Bobbin ODI 13 1.67 13TH TSP

+27.47 F/L 05/94 RF0 C/L Special Int VOL 1.22 12TH TSP

-15.44 12TH TSP

BWNS TUBAN II (Version 2.0) 06/17/1994 06:29:03 eeee********************"***

Catawba Nuclear Station Unit Two e***e***********************

$/G C 05/94 RF0 e............+.......*******

Bobbin,C/L Special Interest,H/L Specist Interest,H/L Tubesheet,U-Bend i

Page 15 of 27 l

S/G C - ATTACHMENT #3 INDICATIONS OF IMPERFECTIONS RDW COL OUTACE TEST TYPE INO %fW VOLTS LOCATION EXTENT 1 28 92 05/94 RF0 Bobbin ADI 4.89 11TH TSP

- 7. 72 F/L 05/94 RF0 C/L Special Int VOL 0.66 11TH TSP

-9.04 11TH TSP 05/94 RF0 C/L Special Int VOL 0.76 11TH TSP

+0.94 11TH TSP 05/94 RF0 C/L Special int VOL 0.78 11TH TSP 7.72 11TH TSP 28 95 05/94 RF0 Bobbin AOI 4.96 11TH TSP

+22.63 to +25.97 F/L 05/94 RF0 C/L Special Int VOL 0.21 11TH TSP

+22.63 to +25.97 11TH TSP 28 96 05/94 RF0 Bobbin 001 7

1.08 7TH TSP

+16.74 F/L 05/94 RF0 Bobbin 001 4

1.12 1CTH TSP

+18.09 F/L 28 100 05/94 RF0 Bobbin NQI 0.81 16TH TSP

-5.16 F/L 05/94 RF0 Bobbin ho!

0.94 13TH TSP

-3.44 F/L 05/94 RF0 Bobbin 001 31 1.75 6TH TSP

+7.63 F/L 05/94 RF0 C/L Special Int VOL 0.51 16TH TSP

-5.16 16TH TSP 05/94 RF0 C/L Special Int VOL 0.65 13TH TSP

-3.44 13TH TSP 28 103 05/94 RF0 Bobbin ads 2.04 12TH TSP

+24.37 F/L 05/94 RF0 C/L Special Int VOL 0.25 12TH TSP

+23.02 12TH TSP 05/94 RF0 C/L Special Int VOL 0.28 12TH TSP

+24.37 12TH TSP 29 28 05/94 RF0 Bobbin 001 9

0.64 7TH TSP

+39.12 F/L 1

05/94 RF0 Bobbin 001 16 1.19 9TH TSP 0.65 F/L 05/94 RF0 Bobbin 001 25 0.41 TTH TSP

+38.38 F/L 29 42 05/94 RF0 Bobbin 001 29 0.46 10fH TSP

+33.55 F/L i

29 50 05/94 RF0 Bobbin DDI 20 0.67 12TH TSP

+37.17 f/L 29 59 05/94 RF0 Bobbin 001 14 1.63 17TH TSP

-1,61 F/L 05/94 RF0 C/L Special Int VOL 0.54 17TH TSP

-1.98 17TH TSP 29 65 05/94 RF0 Bobbin Nol 1.07 13TH TSP

+34.21 F/L 05/94 RF0 C/L Special Int VOL 0.36 12TH TSP

-8.70 12TH TSP 29 71 05/94 RF0 Bobbin NQI 0.51 10TH TSP

+38.13 F/L 05/94 RF0 Bobbin NQI 1.86 10TH TSP

+39.36 F/L 29 75 05/94 RF0 Bobbin No!

0.85 71H TSP

+33.94 F/L 05/94 RF0 Bobbin Nol 1.81 7TH TSP

+17.94 F/L 05/94 RIO H/L Speclat Int VOL 0.61 7TH TSP

+17.58 8TH TSP 05/94 RF0 H/L Special Int VOL 1.01 7TH TSP

+33. 73 STH TSP 05/94 RF0 H/L Special Int VOL 2.39 7TH TSP

+34.84 BTH TSP 29 76 05/94 RF0 Bobbin NOI 0.38 10TH TSP

+32.51 F/L 05/94 RF0 Bobbin 001 4

1.42 7TH TSP

+16.06 F/L 05/94 RF0 Bobbin 001 4

1.15 10TH TSP

+22.52 F/L 05/94 RF0 Bobbin 001 21 1.06 10TH TSP

+33.58 F/L 05/94 RF0 Bobbin 001 35 0.41 10TH TSP

+21.45 F/L i

29 79 05/94 RF0 Bobbin 001 7

1.00 7TH TSP

+8.44 F/L 29 90 05/94 RF0 Bobbin 001 13 1.30 13TH TSP

+34.43 F/L 05/94 RF0 Bobbin 001 15 1.24 11TH TSP

+4.12 F/L 29 92 05/94 RF0 Bobbin ADI 1.94 10TH TSP

-2.08 F/L 05/94 RF0 Bobbin ADI 4.66 12TH TSP

+21.71 F/L 05/94 RF0 Bobbin AOI 4.76 14TH TSP

-2.41 F/L 05/94 RF0 C/L Special Int VOL 0.65 14TH TSP

-2.41 14TH TSP 05/94 RF0 C/L Special Int VOL 0.66 10TH TSP

-2.08 10TH TSP 05/94 RF0 C/L Special Int VOL 0.67 12TH TSP

+21.71 12TH TSP 29 94 05/94 RF0 Bobbin ADI 5.81 11TH TSP

+8.64 F/L 05/94 RF0 C/L Special Int VOL 0.66 11TH TSP

+8.64 11TH TSP 29 98 05/94 RF0 Bobbin No!

1.12 11TH TSP

+34.57 F/L 05/94 RF0 C/L Special Int VOL 1.08 10TH TSP

-8.18 10TH TSP 29 101 05/94 RF0 Bobbin Nol 0.67 2ND TSP

+6.60 F/L 05/94 RF0 Bobbin NQI 1.00 19TH TSP

-4.41 F/L 05/94 RF0 H/L Special Int VOL 1.22 2ND TSP

+5.84 2ND TSP 05/94 RF0 C/L Spectet Int VOL 0.37 19TH TSP

-4.41 197H TSP 30 23 05/94 RF0 Bobbin 001 4

1.21 12TH TSP

+29.93 F/L 30 24 05/94 RF0 Bobbin DDI 26 0.56 97H TSP

-1.19 F/L 30 39 05/94 RF0 Bobbin 001 28 1.B4 10TH TSP

+27.97 F/L 05/94 RF0 C/L Special Int VOL 1.83 10TH TSP

+27.49 10TH TSP 30 41 05/94 RF0 Bobbin A01 2.88 16TH TSP

+13.32 F/L 05/94 RF0 Bobbin 001 6

1.06 6TH TSP

+11.11 F/L 05/94 RFC Bobbin 001 17 2.00 6TH TSP

+23.25 F/L 05/94 RF0 Boboin 001 28 1.06 6TH TSP

+21.85 F/L 05/94 RF0 Bobt in 001 28 1.41 6TH TSP

+16.06 F/L 05/94 RF0 Bobbin 001 35 1.57 6TH TSP

+12.74 F/L 05/94 RFC Bobbin 001 14 1.82 177H TSP

+14.56 F/L 05/94 RF0 Bobbin DDI 26 1.7316TH TSP

+1.63 F/L

BWNS TUBAN II (Versior.2.0) 06/17/1994 06:29:03 e........................***

Catawba Nuclear Station - Unit Two S/G C e................***********

05/94 RF0 e....................*******

Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U Bend Page 16 of 27 S/G C - ATTACHMENT #3 INDICATIONS OF IMPERFECTIONS ROW COL DUTAGE TEST TYPE IND %TW VOLTS LOCATION EXTENT 1 05/94 RF0 Bobbin 001 30 2.27 16TH TSP

-1.18 F/L 05/94 RF0 Bobbin 001 33 0.82 16TH TSP

+5.61 F/L 05/94 RF0 H/L Special Int VOL 0.51 6TH TSP

+20.71 6TH TSP 05/94 RF0 H/L Special Int VOL 0.63 6TH TSP

+11.00 6TH TSP 05/94 RF0 H/L Special Int VOL 0.79 6TH TSP

+12.83 6TH TSP 05/94 RF0 C/L Special Int VOL 0.61 16TH TSP

-3.57 16TH TSP 05/94 RF0 C/L Special Int VOL 0.63 15TH TSP

-5.79 1STH TSP 05/94 RF0 C/L Special Int VOL 0.70 16TH TSP

+1.64 16TH TSP 05/94 RF0 C/L Special Int VOL 0.76 16TH TSP

-4.85 16TH TSP 05/94 RF0 C/L Special Int VOL 0.91 16TH TSP

-1.43 16TH TSP 30 47 05/94 RF0 Bobbin DDI 31 0.87 9TH TSP

+0.98 F/L 30 54 05/94 RF0 Bobbin 001 26 1.59 STH TSP

+4.44 F/L 30 59 05/94 RF0 Bobbin ADI 7.67 10TH TSP

+5.56 F/L 05/94 RF0 C/L Special Int VOL 0.56 10TH TSP

+4.70 10TH TSP 30 67 05/94 RF0 Bobbin 001 8

3.19 1AVB

+7.26 F/L 30 69 05/94 RFJ Bobbin NQI 0.92 14TH TSP

+12.99 F/L 05/94 RF0 C/L Special Int VOL 0.20 14TH TSP

+12.76 14TH TSP 30 72 05/94 RF0 Bobbin NQI 0.97 STH TSP

+10.77 F/L 05/94 RF0 Bobbin No!

0.30 11TH TSP

+19.13 F/L 05/94 RF0 Bobbin h0!

D.74 12TH TSP

+19.25 F/L 05/94 RF0 H/L Special Int VOL 1.58 STH TSP

+11.12 5TH TSP 05/94 RF0 C/L Special Int VOL 0.47 11TH TSP

+19.13 11TH TSP 05/94 RF0 C/L Special Int VOL 0.72 12TH TSP

+19.25 12TH TSP 30 73 05/94 RF0 Bobbin No!

0.78 13TH TSP

+27.82 F/L 05/94 RF0 Bobbin No!

0.95 13TH TSP

+25.92 F/L 05/94 RF0 C/L Special Int VOL 0.75 13TH TSP

+27.82 13TH TSP 05/94 RF0 C/L Specist Int VOL 1.04 13TH TSP

+25.92 13TH TSP 30 75 05/94 RFO Bobbin ODI 12 1.94 11TH TSP

+14.67 F/L 30 78 05/94 RFC Bobbin 001 12 1.04 9TH TSP

-3.11 F/L 30 79 05/94 RF0 Bobbin A01 0.58 12TH TSP

+4.00 F/L 30 81 05/94 RF0 Bobbin 001 14 0.88 11TH TSP

+35.62 F/L 30 87 05/94 RF0 Bobbin No!

0.88 2ND TSP

+19.42 F/L 05/94 RFC H/L Special Int VOL 0.52 2ND TSP

+18.13 2ND TSP 05/94 RF0 H/L Special Int VOL 1.33 2ND TSP

+5.09 2ND TSP 30 93 05/94 RF0 Bobbin NQI 0.69 16TH TSP

+4.70 F/L 05/94 RF0 Bobbin 001 13 1.02 16TH TSP

+5.41 F/L 05/94 RF0 C/L Special Int VOL 0.56 16TH TSP

+4.70 16TH TSP 05/94 RF0 C/L special Int VOL 0.67 16TH TSP

+1.47 16TH TSP 30 105 05/94 RF0 Bobbin ADI 3.63 STH TSP

-B.13 F/L 05/94 RF0 Bobbin NQI 0.28 10TH TSP

+44.44 F/L 05/94 RF0 H/L Special Int VOL 0.76 STH TSP

-7.86 STH TSP 31 12 05/94 RF0 Bobbin WAR 14 0.81 3AVB

+0.00 F/L 31 24 05/94 RF0 Bobbin 001 2

2.96 2ND TSP

+29.50 F/L 05/94 RF0 Bobbin 001 9

1.73 STH TSP

+35.04 F/L 05/94 RFC Bobbin 001 14 0.69 10TH TSP

-0.81 F/L 05/94 RF0 Bobbin 001 28 0.85 10TH TSP

+28.60 F/L 31 28 05/94 RF0 Bobbin 001 35 0.74 97H TSP 0.64 F/L 31 42 05/94 RF0 Robbin 001 1

0.90 BTH TSP

-2.51 F/L 31 43 05/94 RF0 Bobbin 001 14 0.41 9TH TSP

+0.56 F/L 31 46 05/94 RF0 Sobbin DDI 4

1.28 BTH TSP

-2.54 F/L 05/94 RF0 Bobbin 001 16 0.58 9TH TSP

-0.72 F/L 05/94 RF0 C/L Special Int VOL 1.47 97H TSP

-0.74 9TH TSP 05/94 RF0 H/L Special Int VOL 1.63 BTH TSP

-2.07 8TH TSP 31 63 05/94 RF0 Bobbin N31 0.94 10TH TSP

+24.10 F/L 05/94 RF0 C/L Special Int VOL 0.67 10TH TSP

+22.17 10TH TSP 31 66 05/94 RF0 Bobbin ADI 2.01 9TH TSP

-5.55 F/L 05/94 RF0 Bobbin NQI 0.80 12TH TSP

+34.29 F/L 05/94 RF0 Bobbin NQI 1.80 10TH TSP

+40.37 F/L 05/94 RF0 C/L Special Int VOL 0.35 111H TSP 8.73 11TH TSP 31 69 05/94 RF0 Bobbin ADI 0.68 14TH TSP

+1.45 F/L 31 70 05/94 RFC Bobbin No!

0.57 6TH TSP

+2.56 F/L 05/94 RF0 Bobbin No!

0.20 13TH TSP

+10.10 F/L 05/94 RF0 Bobbin N31 0.37 117H TSP

+25.37 F/L 05/94 RF0 Bobbin No!

0.69 14TH TSP

+9.30 F/L 05/94 RF0 H/L Special Int VOL 0.59 6TH TSP

+2.89 6TH TSP 05/94 RF0 C/L Special Int VOL 0.2711TH TSP

+25.55 11TH TSP

eeeeee...............e******

BWNS TUBAN II (Version 2.0) 06/17/1994 06:29:03 eeeeee.........*************

Catawba Nuclear StatIDn - Unit Two e.

S/G C e***************************

05/94 RF0 Bobbin,C/L Special Interest,H/L Spe:lal Interest,H/L Tubesheet,U-Bend eeeeee............**********

Page 17 of 27 S/G C - ATTACHMENT #3 INDICATIONS OF IMPERFECTIONS ROW COL DUTAGE TEST TYPE IND %TW VOLTS LOCATION EXTENT 1 05/94 RF0 C/L Special Int VOL 0.45 13fH TSP

+9.90 131H TSP 31 71 05/94 RF0 Bobbin 001 10 0.72 10TH TSP

+17.12 F/L 31 72 05/94 RF0 Bobbin NQI 0.69 4AVB

-13.74 F/L 31 76 05/94 RF0 Bobbin Nwl 0.4817TH TSP

+11.01 F/L 05/94 RF0 C/L Special Int VOL 0.57171H TSP

+10.93 177H TSP 31 80 05/94 RF0 Bobbin ADI 5.75 13TH TSP

+39.55 F/L 05/94 RF0 C/L Special Int VOL 0.51 12TH TSP

-3.47 12TH TSP 31 90 05/94 RF0 Bobbin ADI 0.301ST TSP

+17.42 F/L 05/94 RF0 H/L Special Int VOL 1.03 2ND TSP

-11.37 2ND TSP 32 12 05/94 RF0 Bobbin WAR 12 0.74 1AVB

+0.00 F/L 05/94 RF0 Bobbin WAR 29 2.48 4Avs

+0.00 F/L 05/94 RF0 Bobbin WAR 35 3.53 3AVB

+0.00 F/L 05/94 RF0 U-Bend VOL 1.97 3AVB

+0.00 9TH TSP 05/94 RF0 U-Bend VOL 2.13 4AVB 40.00 9TH TSP 05/94 RF0 Bobbin WAR 27 2.36 4AVB

+0.00 4TH TSP 05/94 RF0 Bobbin WAR 34 3.42 3AVB

+0.00 4TH TSP 32 46 05/94 RF0 Bobbin 001 32 0.73 7TH TSP 3.09 F/L 32 47 05/94 RF0 Bobbin ADI 3.28 1AVB

+13.05 F/L 05/94 RF0 U Bend VOL 2.80 1AVB

+13.84 1AVB 32 59 05/94 RF0 Bobbin ADI 3.27 77H TSP

+15.88 F/L 05/94 RF0 Bobbin 001 22 1.73 7TH TSP

+ 15. 75 F/L 05/94 RF0 H/L Special Int VOL 1.78 7TH TSP

+16.50 7TH TSP 32 62 05/94 RF0 Bobbin NQI 0.32 13fH TSP

+22.69 F/L 05/94 RF0 C/L Special Int VOL 0.21 13TH TSP

+22.69 13fH TSP 32 65 05/94 RF0 Bobbin NQI 1.33 10TH TSP

+13.74 F/L 05/94 RF0 C/L Special Int VOL 0.88 10TH TSP

+13.60 10TH TSP 32 67 05/94 RF0 Bobbin 001 7

1.39 1ST TSP

+13.90 F/L 32 71 05/94 RF0 Bobbin No!

1.41 2AVB

+12.24 F/L 05/94 RF0 U Bend VOL 1.98 2AVB

+11.96 3AVB 05/94 RF0 Bobbin NQ!

0.42 12TH TSP

+21.65 F/L 05/94 RF0 Bobbin 001 11 0.73 12TH TSP

+22.58 F/L 32 73 05/94 RF0 Bobbin 001 8

0.71 12TH TSP

+35.01 F/L 05/94 RF0 Bobbin 001 10 0.61 12TH TSP

+33.94 F/L 32 75 05/94 RFO Bobbin N01 1.59 10TH TSP

+40 70 F/L 32 77 05/94 RF0 Bobbin 001 8

1.73 1AVB

+17'18 F/L 32 78 05/94 RF0 Bobbin 001 3

0.66 17TH TSP

-9.64 F/L 32 79 05/94 RF0 Bobbin 001 15 0.32 10TH TSP

+44.76 F/L 32 82 05/94 RF0 Bobbin NQI 0.33 12TH TSP

+21.54 F/L 05/94 RF0 C/L Special Int VOL 0.39 12TH TSP

+21.88 12TH TSP 32 83 05/94 RF0 Bobbin 001 1

1.1810TH TSP

+42.94 F/L 05/94 RF0 Bobbin DDI 2

1.88 10TH TSP

+42.42 F/L 05/94 RF0 Bobbin 001 18 0.77 10TH TSP

+41.73 F/L 32 84 05/94 RF0 Bobbin No!

0.95 1ST TSP

+23.94 F/L 05/94 RF0 Bobbin NQI 1.43 2ND TSP

+3.30 F/L 05/94 RF0 H/L Special Int VOL 0.17 2ND TSP

+3.04 2ND TSP 05/94 RF0 H/L Special Int VOL 0.46 2ND TSP

-4.12 2ND TSP 32 85 05/94 RF0 Bobbin ADI 2.10 10TH TSP

+43.14 F/L 05/94 RF0 Bobbin NCI 0.35 16TH TSP

+5.74 F/L 05/94 RF0 Bobbin 001 8

0.50 9TH TSP

-1.10 F/L 05/94 RF0 Bobbin 001 6

1.59 10TH TSP

+41.83 F/L 05/94 RF0 C/L Special Int VOL 1.63 9TH TSP

-3.73 9TH iSP 05/94 RF0 C/L Special Int VOL 2.05 9TH TSP

-2.60 9TH TSP 32 86 05/94 RF0 Bobbin 001 14 2.50 3AVB

+18.93 F/L 05/94 RF0 Bobbin NQI 0.93 11TH TSP

-1.97 F/L 05/94 RF0 C/L Special Int VOL 0.34 11TH TSP

-2.39 11TH TSP 32 90 05/94 RF0 Bobbin NQ1 0.86 9tH TSP

-1.77 F/L 05/94 RFO Bobbin 001 25 0.81 STH TSP

-4.80 F/L 05/94 RF0 C/L Special Int VOL 0.88 97H TSP

-1.68 9TH TSP 32 93 05/94 RF0 Bobbin 001 10 0.83 STH TSP

+25.05 F/L 33 14 05/94 RF0 Bobbin WAR 18 1.15 2AVB

+0.00 F/L 33 24 05/94 RF0 Bobbin 001 22 1.20 4TH ISP

+11.42 F/L 05/94 RfD Bobbin 001 3

1.60 10TH TSP

+43.96 F/L 05/94 RF0 Bobbin 001 6

1.31 12TH TSP

+32.82 F/L 05/94 RF0 C/L Special Int VOL 0.18 97H TSP

-0 S6 9TH TSP 05/94 RF0 C/L Special Int VOL 0.18 9TH TSP

-2.17 9TH TSP 05/94 RF0 C/L Special Int VOL 0.42 97H TSP 0.85 9TH TSP

1

... nee *********"********

BWNS TUBAN II (Version 2.0) 06/17/1994 06:29:03 e.. eee..................***

Catawba Nuclear Station - Unit Two e e e e e e............... * " * * "

S/G C eeeeee.................u.**

05/94 RF0 e********************"*****

Bobbin,C/L Special Interest,H/L Special interest,H/L Tubesheet.U-Bend Page 18 of 27 S/G C - ATTACHMENT #3 INDICATIONS OF IMPERFECTIONS ROW COL OUTAGE TEST TYPE

]ND %TW VOLTS LOCATION EXTENT 1 05/94 RF0 C/L special Int VOL 1.85 9TH TSP

-2.96 9TH TSP 05/94 RF0 C/L Special Int VOL 2.33 97H TSP

-1.47 9TH TSP 05/94 RF0 H/L Special Int VOL 0.69 4TH TSP

+8.18 4TH TSP 05/94 RF0 H/L Special Int VOL 0.75 4TH TSP

+9.42 4TH TSP 05/94 RF0 H/L Special int VOL 0.84 4TH TSP

+11.39 4TH TSP 05/94 RF0 C/L Special Int VOL 1.07 11TH TSP

-13.76 11TH TSP 05/94 RF0 C/L Special Int VOL 2.02 11TH TSP

-12.30 11TH TSP 33 30 05/94 RF0 Bobbin CD!

2 1.41 77H TSP

+29.75 F/L i

33 42 05/94 RF0 Bobbin 001 16 0.52 TTS-CL

+4.23 F/L 33 45 05/94 RF0 Bobbin NQI 0.90 16TH TSP

+14.71 F/L 05/94 RF0 C/L Specist Int VOL 0.99 15TH TSP

-4.19 15T4 TSP

+ 33 49 05/94 RF0 Bobbin ODI 16 2.89 1ST TSP

+12.48 F/L 33 54 05/94 RF0 Bobbin ODI 3

2.95 9TH TSP

+1.30 F/L 33 55 05/94 RF0 Bobbin ODI 27 0.71 1AVB

+11.81 F/L 05/94 RF0 Bobbin WAR 27 2.10 3AVB

+0.00 F/L 05/94 RF0 Bobbin 001 7

3.00 9TH TSP

+1.36 F/L 33 59 05/94 RF0 Bobbin 001 21 2.47 10TH TSP

+36.63 F/L 33 64 05/94 RF0 Bobbin 001 31 1.09 4TH TSP

+10.04 F/L 33 65 05/94 RF0 Bobbin NQI 0.89 2ND TSP

+8.45 F/L 05/94 RF0 H/L Special Int VOL 1.83 2ND TSP

+12.33 2ND TSP 33 68 05/94 RF0 Bobbin NQI 0.62 9TH TSP

-6.53 F/L 05/94 RF0 C/L Special Int VOL 0.94 9TH TSP

-6.49 9TH TSP 33 75 05/94 RFO Bobbin ODI 9

0.66 15TH TSP

+13.31 F/L 33 76 05/94 RF0 Bobbin ODI 21 0.94 11TH TSP

+6.97 F/L 33 80 05/94 RF0 Bobbin NQI 0.41 18TH TSP

+3.85 F/L 05/94 RF0 C/L Specist Int VOL 0.50 18TH TSP

+3.95 187H TSP 33 84 05/94 RF0 Bobbin ADI 2.08 11TH TSP

+17.33 F/L 33 87 05/94 RF0 Bobbin 001 12 0.83 10TH TSP

+11.43 F/L 33 90 05/94 RF0 Bobbin ADI 4.09 17TH TSP

+4.06 F/L 05/94 RF0 C/L Special Int VOL 0.4717TH TSP

+3.65 1TTH TSP 33 94 05/94 RF0 Bobbin 001 11 0.87 9TH TSP

-4.75 F/L 34 15 05/94 RF0 Bobbin NOI 0.70 9TH TSP

+1.08 F/L 05/94 RF0 U-Bend VOL 1.01 9TH TSP

+1.17 9TH TSP 34 20 05/94 RF0 Bobbin WQI 0.49 6TH TSP

+9.76 F/L 05/94 RF0 Bobbin NQI 0.69 77H TSP

+36.88 F/L 05/94 RF0 Bobbin NQI 0.82 STH TSP

+3.57 F/L 05/94 RF0 Bobbin NQI 0.53 12TH TSP

+15.41 F/L 05/94 RF0 Bobbin NQI 0.67 14TH TSP

+3.83 F/L 05/94 RF0 Bobbin NQI 1.00 10TH TSP

+6.03 F/L 05/94 RF0 H/L Special int VOL 0.41 6TH TSP

+9.85 F.TH TSP 05/94 RF0 H/L Special int VOL 0.58 STH TSP

+3.61 STH TSP 05/94 RF0 H/L Special Int VOL 0.78 BTH TSP

-5.35 BTH TSP 05/94 RF0 C/L Special Int VOL 1.05 10TH TSP

+5.43 10TH TSP 34 22 05/94 RF0 Bobbin ODI 28 0.63 10TH TSP

+4.04 F/L 34 25 05/94 RF0 Bobbin 001 6

1.73 10TH TSP

+23.68 F/L 34 28 05/94 RF0 Bobbin NQ1 0.35 131H TSP

+27.22 F/L 05/94 RF0 Bobbin No!

0.42 13TH TSP

+24.97 F/L 05/94 RF0 C/L Special Int VOL 0.36 12TH TSP 4.13 12TH TSP 05/94 RF0 C/L Special Int VOL 0.47 12TH TSP

-17.12 12TH TSP 05/94 RF0 C/L Special Int VOL 0.49 12TH TSP 10.31 12TH TSP 05/94 RF0 C/L Special Int VOL 0.51 12TH TSP

-15.06 12TH TSP 34 33 05/94 RFC Bobbin NQI 2.58 2AVB

+3.42 F/L 05/94 RF0 U-Bend VOL 4.63 2AVB

+1.82 2AVB 34 39 05/94 RF0 Bobbin NQI 0.41 11TH TSP

+10.01 F/L 05/94 RF0 C/L Special Int VOL 0.59 11TH TSP

+8.55 11TH TSP 34 41 05/94 RF0 Bobbin 001 8

1.00 4TH TSP

+24.46 F/L 34 54 05/94 RF0 Bobbin ADI 3.14 13fH TSP

+16.36 F/L 34 56 05/94 RF0 Bobbin ADI 4.65 3AYB

+13.48 F/L 05/94 RF0 U-Bend VOL 0.33 4AVB

+11.86 9TH TSP 34 61 05/94 RF0 Bobbin 001 8

1.56 9tH TSP

-9.23 F/L i

34 63 05/94 RF0 Bobbin ADI 2.28 7TH TSP

-6.56 F/L 1

05/94 RF0 H/L Special Int VOL 0.60 7TH TSP

-6.00 7TH TSP 05/94 RF0 H/L Special Int VOL 0.62 7TH TSP

-7.13 7TH TSP 34 68 05/94 RF0 Bobbin NQI 1.20 11TH TSP

+5.78 F/L 1

05/94 RF0 C/L Special Int VOL 1.14 11TH TSP

+6.30 11TH TSP

)

34 72 05/94 RF0 Bobbin ADI 1.93 3RD TSP

  • 24.49 F/L

i eeeeeee*********************

BWNS TUBAN !! (version 2.0) 06/17/1994 06:29:03 e...........****************

Catawba Nuclear Station - Unit Two e..

Sfg g e............***************

05/94 RF0 Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U-Bend ee.................*********

Page 19 of 27 S/G C ATTACHMENT #3 INDICATIONS OF IMPERFECTIONS ROW COL DUTAGE TEST TYPE IND %TW VOLTS LOCAfl0N EXTENT 1 05/94 RF0 Bobbin ADI 2.44 9TH TSP

-7.38 F/L 05/94 RF0 Bobbin NQ1 1.16 18TH TSP

+7.88 F/L 05/94 RF0 Bobbin 001 28 0.55 10TH TSP

+8.91 F/L 05/94 RF0 C/L Special Int VOL 0.74 97H TSP

-7.38 9TH TSP 05/94 RF0 H/L Special Int VOL 0.40 3RD TSP

+20.51 3R0 TSP 05/94 RF0 H/L Special Int VOL 0.66 3RD TSP

+21.96 3RD TSP 05/94 RF0 M/L Special Int VOL 0.95 3RD TSP

+20.01 3RD TSP 05/94 RF0 C/L Special Int VOL 0.82 181H TSP

+8.27 18TH TSP 34 82 05/94 RF0 Bobbin 001 10 1.75 12TH TSP

+34.80 F/L 34 83 05/94 RF0 Bobbin 001 10 1.73 12TH TSP

+34.30 F/L 34

  • 5 05/94 RF0 Bobbin 001 13 1.45 19TH TSP

+1.91 F/L 34 86 05/94 RF0 Bobbin DDI 7

2.53 2ND TSP

+17.00 F/L 05/94 RF0 Bobbin DDI 11 1.58 18TH TSP

+11.14 F/L 34 87 05/94 RF0 Bobbin 001 13 2.66 12TH TSP

+20.03 F/L t

34 88 05/94 RF0 Bobbin 001 19 0.7310TH TSP

+11.85 F/L 34 102 05/94 RF0 Bobbin 001 11 0.98 15TH TSP

-2.38 F/L 35 24 05/94 RF0 Bobbin NQI 0.67 4TH TSP

+9.82 F/L 05/94 RF0 Bobbin NQI 0.29 11TH TSP

+21.08 F/L 05/94 RF0 Bobbin NQI 1.31 10TH TSP

+5.72 F/L 05/94 RF0 Bobbin ODI 5

0.60 11TH TSP

+22.10 F/L 05/94 RF0 H/L Special Int VOL 0.54 4TH TSP

+9.89 4TH TSP 05/94 RF0 C/L Special Int VOL 0.41 10TH TSP

-20.63 10TH TSP 05/94 RF0 C/L Special Int VOL 0.59 10TH TSP

+0.86 10TH TSP 05/94 RF0 C/L Special Int VOL 0.70 10TH TSP

-19.69 10TH TSP 05/94 RTO C/L Special Int VOL 1.00 10TH TSP

+5.44 10TH TSP 35 27 05/94 RF0 Bobbin NQ1 0.75 1ST TSP

+16.60 F/L 05/94 RF0 H/L Specist Int VOL 0.98 157 TSP

+15.30 1ST TSP 35 12 05/94 RF0 Bobbin 001 4

0.50 13TH TSP

-1.08 F/L 05/94 RF0 C/L Special Int v0L 0.62 13TH TSP

-0.78 13TH TSP 35 34 05/94 RF0 Bobbin 001 29 0,47 13fH TSP

-5.52 F/L 35 39 05/94 RF0 Bobbin NQI 0.87 13TH TSP

-4.75 F/L 35 40 05/94 RF0 Bobbin ADI 6.79 3 AVG

+5.60 F/L 05/94 RF0 Bobbin ADI 10.65 3AVB

+ 1. 64 F/L 05/94 RF0 U Bend VOL 0.88 3 Ave

+1.00 3AVB 05/94 RF0 U Bend VOL 1.27 2AVB

+ 0. 73 2AVB 05/94 RF0 U-Bend VOL 5.12 3AVB

+4.53 3AVB 05/94 RF0 Bobbin NQI 0.96 71H TSP

+32.B4 F/L 05/94 RF0 H/L Special int VOL 0.60 BTH TSP

-10.93 STN TSP i

35 41 05/94 RF0 Bobbin NGI 0.59 11TH TSP

+33.48 F/L 35 56 05/94 RF0 Bobbin NQI 1.01 BTH TSP

-7.53 F/L 05/94 RF0 N/L Special Int VOL 0.58 BTH TSP

-7.57 BTH TSP 35 61 05/94 RF0 Bobbin NQ1 0.41 4TH TSP

+12.41 F/L 05/94 RF0 H/L Special Int VOL 0.19 4TH TSP

+12.79 4TH TSP 35 62 05/94 RF0 Bobbin 001 18 1.04 10TH tsp

+34.15 F/L 35 64 05/94 RF0 Bobbin ADI 5.64 2N9 TSP

+12.27 to +22.47 F/L 05/94 RF0 H/L Special Int VOL 1.22 2ND TSP

+19.31 2ND TSP 05/94 RF0 H/L Special Int VOL 1.55 2ND TSP

+12. 64 2ND TSP 05/94 RF0 H/L Special Int VOL 1.65 2ND TSP

+20.70 2ND TSP 05/94 RF0 H/L Special Int VOL 1.71 2ND TSP

+ 17. B4 2ND TSP 05/94 RF0 H/L Special Int VOL 1.78 2ND TSP

+15.90 2ND TSP 35 65 05/94 RF0 H/L Tubesheet VOL 0.69 TTS HL

+1.62 TTS-HL 35 74 05/94 RF0 Bobbin 001 15 0.90 10TH TSP

+40.01 F/L 35 79 05/94 RF0 Bobbin DDI 18 1.38 iSTH TSP

+3.07 F/L 05/94 RF0 C/L Special Int VOL 0.26 15TH TSP

+2.52 15TH TSP 35 80 05/94 RF0 Bnbbin NQI 0.57 17TH TSP

+ 7. 64 F/L 05/94 RF0 C/L Special Int VOL 0.21 17TH TSP

+ 7.44 17TH TSP 35 87 05/94 RF0 Bobbin 001 12 1.15 STH TSP

+13.06

  • /L 35 89 05/94 RF0 Bobbin 001 5

4.54 7TH TSP

+5.77

'/L 05/94 RF0 H/L Special Int VOL 1.11 7TH TSP

+6.03

?TH TSP 35 91 05/94 RF0 Bobbin DDI 8

3.68 2ND TSP

-3.02 F/!

35 96 05/94 RF0 Bobbin DDI 16 1.63 17TH TSP

+15.86 F/L 36 21 05/94 RF0 Bobbin 001 8

0.90 97H TSP 9.96 F/L 05/94 RF0 C/L Special Int VOL 0.93 97H TSP

-9.55 9TH TSP 05/94 RF0 C/L Special Int VOL 1.56 97H TSP

-8.34 9TH TSP 36 31 05/94 RF0 Bobbin 001 7

1.85 11TH TSP

+31.62 F/L 05/94 RF0 Bobbin 001 14 2.00 11TH TSP

+37.07 F/L

eeeee.........**************

BWNS TUBAN 11 (Version 2.0) 06/17/1994 06:29:03 Catawba Nuclear Station - Unit Two S/G C e...

05/94 RF0 Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U-Bend eeeeeee*********************

Page 20 of 27 S/G C - ATTACHMENT #3 INDICATIONS OF IMPERFECTIONS RDW COL DUTAGE TEST TYPE IND %TW VOLTS LOCATION EXTENT 1 36 40 05/94 RF0 Bobbin NQI 0.80 11TH TSP

-1.63 F/L 05/94 RF0 Bobbin NQ1 0.88 13fH TSP

+40.65 F/L 05/94 RF0 C/L Special Int VOL 0.23 12TH TSP

-2.17 12TH TSP 05/94 RF0 C/L Special Int VOL 0.3712TH TSP

-8.32 12TH TSP 05/94 RF3 C/L Special Int VOL 0.41 11TH TSP

-1.64 11TH TSP 05/94 RF0 C/L Special Int VOL 0.43 12TH TSP

+ 7. 46 12TH TSP 05/94 RF0 C/L Special Int VOL 0.63 12TH TSP

-3.40 12TH TSP 36 54 05/94 RF0 Bobbin No!

0.99 11TH TSP

+15.26 F/L 05/94 RF0 C/L Special Int VOL 0.69 11TH TSP

+14.38 11TH TSP 05/94 RF0 C/L Special Int VOL 1.34 11TH TSP

+15.26 11TH TSP 36 85 05/94 RF0 Bobbin 001 8

1,32 BTH TSP

-4.40 F/L 05/94 RF0 Bobbin 001 10 0.519TH TSP

-1.99 F/L 05/94 RF0 Bobbin DDI 39 0.37 9TH T$P

-3.11 F/L 05/94 RF0 C/L Special Int VOL 0.58 9TH TSP

-3.13 9TH TSP 36 90 05/94 RF0 Bobbin NQ1 1.02 12TH TSP

+19.79 F/L 05/94 RF0 C/L Special Int VOL 0.91 12TH TSP

+20.04 12TH TSP 36 98 05/94 RF0 Bobbin WAR 11 0.72 2AVB

+0.00 F/L 37 16 05/94 RF0 Bobbin 001 5

3.44 2AVB

+5.76 F/L 05/94 RF0 U-Bend VOL 1.12 2AVB

+5.28 8TH TSP 37 22 05/94 RF0 Bobbin DDI 1

0.72 12TH TSP

+23.29 F/L 05/94 RF0 C/L Special Int VOL 0.94 12TH TSP

+23.29 12TH TSP 37 23 05/94 RF0 Bobbin 001 4

0.62 11TH TSP

+35.98 F/L 05/94 RF0 Bobbin 001 16 0.43 11TH TSP

+35.44 F/L 05/94 RF0 Bobbin 001 17 0.33 lith TSP

+34.89 F/L 37 26 05/94 RF0 Bobbin DDI 15 1.64 97H TSP

+0.92 F/L 37 27 05/94 RF0 Bobbin 001 36 1.42 97H TSP

+0.81 F/L 05/94 RF0 Bobbin 001 2

0.91 11TH TSP

+34.99 F/L 37 31 05/94 RF0 Bobbin DDI 15 0.61 17TH TSP

-1.64 F/L 05/94 RF0 C/L Special Int VOL 0.4817TH TSP

-1.65 17TH TSP 37 40 05/94 RF0 Bobbin NCI 0.91 1AVB

+17.85 F/L 05/94 RF0 Bobbin 001 7

1.20 3AVB

+18.37 F/L 05/94 RF0 U-Bend VOL 0.96 1AVB

+14.84 1AVB 05/94 RF0 Bobbin ADI 3.63 4TH TSP

+19.61 F/L 05/s4 RF0 Bobbin 001 19 2.41 7TH TSP

+1.82 F/L 05/54 RF0 Bobbin 001 24 2.15 2ND TSP

+18.64 F/L 05/94 RF0 Bobbin 001 3

4.90 11TH TSP

+6.23 F/L 05/94 RF0 Bobbin 001 14 2.38 11TH TSP

+29.17 F/L 05/94 RF0 H/L Special Int VOL 0.93 4TH TSP

+20.22 4TH TSP 05/94 RF0 H/L Special Int VOL 1.42 71H TSP

+2.31 7TH TSP 37 41 05/94 RF0 Bobbin NOI 1.29 4AVB

-3.83 F/L 05/94 RF0 U-Bend VOL 1.14 4AVB

-3.13 4AVB 37 53 05/94 RF0 Bobbin 001 7 0.87177H TSP

+10.96 F/L 05/94 RF0 Bobbin 001 8

0.51 171H TSP

+4.98 F/L 05/94 RF0 Bobbin 001 8

1.58 10TH TSP

+16.55 F/L 37 61 05/94 RF0 Bobbin NOI 0.47 10TH TSP 1.89 F/L J

05/94 RF0 Bobbin NCI 0.64 10TH TSP

-3.24 F/L 05/94 RF0 C/L Special Int VOL 0.28 10TH TSP

-1.86 10TH TSP 05/94 RF0 C/L Special Int VOL 0.23 10TH TSP 6.39 to

-3.03 10TH TSP l

37 68 05/94 RF0 Bobbin NOI 1.22 12TH TSP + 28. 73 F/L

]

05/94 RF0 C/L Special Int VOL 0.62 12TH TSP

+29.27 12TH TSP 37 72 05/94 RF0 Bobbin NQI 0.71 2ND TSP

-2.45 F/L 05/94 RF0 H/L Special Int VOL 0.67 2ND TSP

+1.92 2ND TSP 05/94 RF0 H/L Special Int VOL 1.05 2ND TSP

-2.41 2ND TSP 37 77 05/94 RF0 Bobbin 001 5

1.35 4TH TSP

+3.10 F/L 05/94 RF0 Bobbin 001 6

2.74 3RD TSP

-5.32 F/L 05/94 RF0 Bobbin 001 10 3.62 2ND TSP

+10.73 F/L 05/94 RTO Bobbin DDI 7

1.5317TH TSP 11.26 F/L 37 86 05/94 RF0 Bobbin ODI 14 0.71 1STH TSP

-3.25 F/L 37 87 05/94 RF0 Bobbin DDI 12 1.42 131H TSP

-3.63 F/L 05/94 RF0 C/L Special Int VOL 0.48 13TH TSP

-6.07 13TH TSP 05/94 RF0 C/L Special Int VOL 0.67 13TH TSP

-3.74 13TH TSP 37 88 05/94 RF0 Bobbin 001 7

1.38 1STH TSP

-10.48 F/L 37 90 05/94 RF0 Bobbin NCI 0.67 4TH TSP

+11.20 F/L 05/94 RF0 Bobbin 001 12 1.69 TTS ML

+5.93 F/L i

05/94 RF0 Bobbin 001 2

0.90 6TH TSP

+29.77 F/L 05/94 RF0 Bobbin 001 6

0.92 6TH TSP

+36.93 F/L

e............ **e..e*******

BWNS TUBAN 11 (Version 2.0) 06/17/1994 06:29:03 Catawba Nuc' ear Station

  • Unit Two e.....e*********************

S/G C 05/94 RF0 e......***..........********

Bobbin,C/6 Special Interest,H/L Special Interest,H/L Tubesheet,U-Bend Page 21 of 27 S/G C - ATTACHMENT #3 INDICATIONS OF IMPERFECTIONS ROW COL DUTAGE TEST TYPE IND %TW VOLTS LOCATION EXTENT 1 05/94 RF0 Bobbin 001 7

2.33 6TH TSP

+13.40 F/L 05/94 RF0 Bobbin 001 8

3.74 4TH TSP

+22.23 F/L 05/94 RFJ Bobbin ODI 9

1.45 4TH TSP

+32.18 F/L 05/94 RF0 Bobbin 001 7

0.99 10TH TSP

+25.31 F/L 37 92 05/94 RF0 Bobbin NQI 1.18 7TH TSP

+23.99 F/L 37 95 05/94 RF0 Bobbin 001 5

1.57 STH TSP

+24.48 F/L 05/94 RF0 Bobbin 001 5

2.18 2ND TSP

-11.68 F/L 05/94 RF0 Bobbin 001 6

1.74 1ST TSP

+11.68 F/L 37 97 05/94 RF0 Bobbin 001 4

1.32 3RD TSP

-9.97 F/L 05/94 RF0 Bobbin DDI 8

0.72 2ND TSP

+23.50 F/L 05/94 RF0 Bobbin 001 9

1.49 3RD TSP

-9.34 F/L 05/94 RF0 Bobbin 001 5

0.87 18TH TSP

-2.52 F/L 37 98 05/94 RF0 Scbbin No!

1.00 BTH TSP

-12.33 F/L 05/94 RF0 H/L Special Int VOL 0.77 BTH TSP

-11.18 STH TSP 37 99 05/94 RF0 Bobbin 001 7

3.58 2AVB

+6.48 F/L 38 17 05/94 RF0 Bobbin WAR 10 0.55 2AVR

+0.00 F/L 38 23 05/94 RF0 Bobbin WAR 8

0.46 4AVB

+0.00 F/L 38 27 05/94 RF0 Bobbin 001 16 1.5711TH TSP

+25.59 F/L 38 34 05/94 RF0 Bobbin WAR 7

0.40 2AVB

+0.00 F/L 38 39 05/94 RF0 Bobbin DDI 12 1.11 16TH TSP

-12.32 F/L 05/94 RF0 Bobbin 001 31 0.56 10TH TSP

+28.58 F/L 38 40 05/94 RF0 Bobbin 001 4

0.81 4TH TSP

+3.85 F/L 38 41 05/94 RF0 Bobbin NQI 0.57 1 AVB

+22.48 F/L 05/94 RF0 Bobbin NQI 0.73 2AVB

+4.62 F/L 05/94 RF0 Bobbin 001 16 1.46 1AVB

+13.43 F/L 05/94 RF0 U Bend VOL 0.93 2AVB

+4.24 2AVB 05/94 RF0 U Bend VOL 2.62 2AVB

-5.33 2AVB 05/94 RF0 U Bend VOL 2.85 2AVB

-14.07 2AVB 05/94 RF0 Bobbin Not D.41 10TH TSP

+37.36 F/L 05/94 RF0 C/L Special Int VOL 1.22 9TH TSP

-8.32 97H TSP 38 69 05/94 RF0 Bobbin NQI 0.97 4TH TSP

+15.42 F/L 05/94 RF0 H/L Special Int VOL 1.33 4TH TSP

+14.58 4TH TSP 38 74 05/94 RF0 Bobbin 001 19 3.18 4AVB

+6.93 F/L 05/94 RF0 Bobbin 001 7

1.86 9TH TSP

-11.29 F/L 38 75 05/94 RF0 Bobbin 001 7

2.23 BTP TSP

-12.87 F/L 38 83 05/94 RF0 Bobbin 001 10 3.38 9TH TSP 0.66 F/L 38 86 05/94 RF0 Bobbin 001 10 0.79 13TH TSP

+11.14 F/L 38 88 05/94 RF0 Bobbin 001 4

2.40 10TH TSP

  • 1.69 F/L 05/94 RF0 Bobbin 001 5

1.83 15fH TSP

-9.15 F/L 38 89 05/94 RF0 Bobbin DDI 10 1.5712TH TSP + 21. 73 F/L 05/94 RF0 C/L Special Int VOL 0.16 12TH TSP

+21.88 12TH TSP 38 90 05/94 RF0 Bobbin ODI 10 1.09 16TH TSP

+15.62 F/L 05/94 RF0 Bobbin DDI 13 0.83 13fM TSP

+18.98 F/L 05/94 RF0 C/L Special Int VOL 0.16 13fH TSP

+19.81 131H TSP 05/94 RF0 C/L Special Int VOL 0.2715f H TSP

-5.91 15TH TSP 05/94 RF0 C/L Special Int VOL 0.37 15TH TSP

-2.16 15fH TSP 38 93 05/94 RF0 Bobbin DDI 10 2.97 16TH TSP

+3.30 F/L 05/94 RF0 Bobbin 001 8

1.68 13fH TSP

+9.86 to +14.96 F/L 38 94 05/94 RF0 Bobbin ODI 33 1.00 4TH TSP

+12.37 F/L 38 95 05/94 RF0 Bobbin 001 10 0.59 13TH TSP

+7.95 F/L 38 96 05/94 RF0 Bobbin 001 18 1.51 10TH TSP

+26.80 F/L 38 97 05/94 RF0 Bobbin WAR 13 0.79 2AVB

+0.00 F/L 05/94 RF0 Bobbin 001 10 0.80 12TH TSP

+11.89 F/L 05/94 RF0 Bobbin 001 12 1.81 131H TSP

+30.05 F/L 05/94 RF0 Bobbin 001 13 1.73 11TH TSP

+30.07 F/L 05/94 RF0 Bobbin 001 16 0.83 12TH TSP

+23.98 F/L 38 99 05/94 RF0 Bobbin WAR 22 1.54 3AVB

+0.00 F/L 05/94 RF0 Bobbin WAR 30 2.53 4AVB

+0.00 F/L 39 17 05/94 RF0 Bobbin WAR 9

0.53 1AVB

+0.00 F/L 39 18 05/94 RF0 Bobbin DDI 33 0.67 97H TSP

+1.12 F/L 39 20 05/94 RF0 Bobbin No!

0.44 137H TSP

+23.17 F/L 05/94 RF0 Bobbin No!

0.46 10TH TSP 4.87 F/L 05/94 RF0 Bobbin Ecl 0.62 15TH TSP

+2.16 F/L 05/94 RF0 Bobbin 001 13 0.51 12TH TSP

+12.66 F/L 05/94 RF0 C/L Special Int VOL 0.42 10TH TSP

-5.65 10TH TSP 05/94 RF0 C/L Special Int vot 0.60 13fH TSP

+23.17 13TH TSP

a.

I e**eeeeeeee**ee......e******

BWNS TUBAN 11 (Version 2.0) 06/17/1994 06:29:03

/

Catawba Nuclear Station - Unit Two eeeeeeee********************

S/G C eeeeee**********************

05/94 RF0 Bobbin,C/L Special Interest,H/L Special Interest H/L Tubesheet,U Bend eeee************************

Page 22 of 27 S/G C - ATTACHMENT #3 INDICATIONS OF IMPERFECTIONS ROW COL DUTAGE TEST TYPE IND %TW VOLTS LOCATION EXTENTl 05/94 RF0 C/L Special Int VOL 0.72 1STH TSP

+2.16 15TH TSP

- 39 22 05/94 RF0 Bobbin 001 12 0.50 4TH TSP

+17.35 F/L

?9 35 05/94 RF0 Bobbin 001 17 0.41 12TH TSP

+30.12 F/L 39 40 05/94 RF0 Bobbin 001 7

0.34 11TH TSP

+38.32 F/L 05/94 RF0 Bobbin 001 7

0.64 10TH TSP

+2.29 F/L 05/94 RF0 Bobbin 001 33 0.26 11TH TSP

+37.07 F/L 39 46 05/94 RF0 Bobbin ADI 7.80 BTH TSP

+28.82 F/L 05/94 RF0 Bobbin ODI 11 0.73 13TH TSP

+12.67 F/L 05/94 RF0 U-Bend VOL 0.71 8TH TSP

+29.12 87H TSP 05/94 RF0 U Bend VOL 1.85 BTH 1SP

+24.95 BTH TSP 39 47 05/94 RF0 Bobbin NQI 0.67 13fH TSP

+25.49 F/L 05/94 RF0 C/L Special Int VOL 0.34 12TH TSP

-18.70 12TH TSP 05/94 RF0 C/L Special Int VOL 1.02 12TH TSP 3.94 12TH TSP 39 55 05/94 RF0 Bobbin 001 5

2.06 4TH TSP

+23.05 F/L 39 62 05/94 RF0 Bobbin 001 21 2.24 13TH TSP

+15.60 F/L 39 73 05/94 RF0 Bobbin ADI 1.67 13TH TSP

+24.36 F/L 39 74 05/94 RF0 Bobbin ADI 5.17 TTS-CL

+5.03 F/L 05/94 RF0 Bobbin ADI 0.96 3RD TSP

+13.42 F/L 05/94 RF0 Bobbin ADI 1.98 7TH TSP

+31.56 F/L 05/94 RF0 Bobbin ADI 3.71 12TH TSP

+20.42 F/L 05/94 RF0 C/L Special Int VOL 0.84 TTS-C.

+4.83 TTS-HL 05/94 RF0 C/L Special Int VOL 0.89 12TH TSP

+19.48 12TH TSP 39 80 05/94 RF0 Bobbin ADI 1.92 18TH TSP

+13.18 F/L 05/94 RF0 C/L Special Int VOL 0.60 17TH TSP

-5.79 177H TSP 39 83 05/94 RF0 Bobbin ADI 2.48 3AVB

+5.78 F/L 39 86 05/94 RF0 Bobbin ADI 3.62177H TSP

+16.14 F/L 05/94 RF0 C/L Special Int VOL 0.58 16TH TSP

-2.71 16TH TSP

!) 89 05/94 RF0 Bobbin NQI 1.19 97H TSP

+1.07 F/L 39 95 05/94 RF0 Bobbin ADI 1.67 13fH TSP

+36.05 F/L 39 96 05/94 RF0 Boboin 001 5

3.08 12TH TSP

+41.24 F/L 05/94 RF0 Bobbin 001 15 1.85 11TH TSP

-1.20 F/L 05/94 RF0 C/L Special Int VOL 1.06 11TH TSP

-1.63 11TH TSP 39 97 05/94 RF0 Bobbin WAR 12 0.69 2AVB

+0.00 F/L 05/94 RF0 Bobbin WAR 16 0.95 4AVB

+0.00 F/L 39 98 05/94 RF0 Bobbin 0D1 3

0.66 10TH TSP

+33.21 F/L 40 19 05/94 RF0 Bobbin 001 26 0.45 10TH TSP

+28.76 F/L 40 30 05/94 RF0 Bobbin 001 10 0.60 11TH TSP

+28.63 F/L 40 32 05/94 RF0 Bobbin 001 10 1.41 6TH TSP

+31.98 F/L 05/94 RF0 Bobbin 001 5

0.46 13TH TSP

-4.80 F/L 40 37 05/94 RF0 Bobbin 001 9

0.91 6TH TSP

+35.76 F/L 40 38 05/94 RF0 Bobbin NQI 0.60 13fH TSP

+7.26 F/L 05/94 RF0 Bobbin DDI 20 2.09 6TH TSP

+33.98 F/L 05/94 RF0 Bobbin 001 12 2.08 17TH TSP

+13.41 F/L 05/94 RF0 C/L Special Int VOL 0.89 13TH TSP

+7.35 13TH TSP 40 46 05/94 RF0 Bobbin 001 8

0.68 6TH TSP

+4.34 F/L 40 47 05/94 RF0 Bcbbin 001 10 0.58 13TH TSP

+7.90 F/L 40 49 05/94 RF0 Bobbin WAR 32 2.69 4AVB

+0.00 F/L 40 50 05/94 RF0 Bobbin 001 1

0.48 10TH TSP

+30.68 F/L 40 69 05/94 RF0 Bobbin DDI 1

1.60 7TH TSP

+9.70 F/L 05/94 RF0 Bobbin 001 11 1.18 11TH TSP

+20.73 F/L 40 73 05/94 RF0 Bobbin NQI 0.97 11TH tsp

+25.85 F/L 05/94 RF0 C/L Special Int VOL 0.80 11TH TSP

+25.97 11TH TSP 40 74 05/94 RF0 Bobbin 001 3

0.45 9TH TSP

+0.40 F/L 40 76 05/94 RF0 Bobbin 001 12 1.43 11TH TSP

+29.46 F/L 40 82 05/94 RF0 Bobbin No!

0.47 6TH TSP

+34.40 F/L 05/94 RF0 H/L Special Int VOL 1.02 7TH TSP

-7.94 TTH TSP 40 B4 05/94 RF0 Robbin NOI 0.49 11TH TSP

+28.40 F/L 05/94 RF0 C/L Special ' Int VOL 0.10 10TH TSP

-13.89 10TH TSP 05/94 RF0 C/L Special Int VOL 0.40 10TH TSP 14.64 10TH TSP 40 85 05/94 RF0 H/L Tubesheet VOL 0.86 TTS-HL

+1.11 TTS-HL 40 87 05/94 RF0 Bobbin 001 8

0.76 10TH TSP

+18.81 F/L 40 88 05/94 RF0 Bobbin ADI 4.57 10TH TSP

+22.85 F/L 05/94 RF0 Bobbin 001 27 0.53 10TH TSP

+33.86 F/L 05/94 RF0 C/L Special Int VOL 1.26 9TH TSP

-22.09 9TH TSP 05/94 RF0 C/L Special Int VOL 2.44 9TH TSP

-10.98 9TH TSP 40 90 05/94 RF0 Bobbin DDI 13 3.07 11TH TSP

+26.15 F/L

1 l

eeeeeeeen.******************

swNS TUBAN II (Version 2.0) 06/17/1994 06:29:03 Catawba Nuclear Station - Unit Two eeeeee................*****

S/G C eeeeee**********************

05/94 RF0 Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U Bend Page 23 of 27 S/G C - ATTACHMENT #3 INDICATIONS CF IMPERFECTIONS ROW COL DUTAGE TEST TYPE IND %TW VOLTS LOCATION EXTENT 1 05/94 RF0 C/L Special Int VOL 0.67 10TH TSP 16.90 10TH TSP 40 92 05/94 RF0 Bobbin ODI 3

1.54 10TH TSP

+31.44 F/L 05/94 RF0 Bobbin ODI 9

0.37 10TH TSP

+30.19 F/L 05/94 RF0 C/L Special Int VOL 1.91 97H TSP

-13.64 9TH TSP 40 93 05/94 RF0 Bobbin 001 6

0.63 7TH TSP

+39.51 F/L 40 96 05/94 RF0 Bobbin 001 8

0.74 7TH TSP

+36.77 F/L 40 97 05/94 RF0 Bobbin 001 21 1.04 10TH TSP

+37.94 F/L 41 34 05/94 RF0 Bobbin 001 14 0.48 14TH TSP

+9.88 F/L 41 48 05/94 RF0 Bobbin IDI 28 7.71 TTS-HL

+0.85 F/L 41 60 05/94 RF0 Bobbin 001 8

0.98 13TH TSP

+20.51 F/L 41 68 05/94 RF0 Bobbin ADI 4.96 11TH TSP

+31.65 F/L 05/94 RF0 C/L Special Int VOL 0.65 10TH TSP

-12.00 10TH TSP 41 76 05/94 RF0 Bobbin DDI 4

2.05 11TH TSP

+38.73 F/L 05/94 RF0 C/L Special Int VOL 1.46 10TH TSP 4.29 10TH TSP 05/94 RF0 C/L Special Int VOL 1.74 10TH TSP

-3.23 10TH TSP 41 83 05/94 RF0 Bobbin N01 1.16 STH TSP

+34.05 F/L 05/94 RF0 H/L Special Int VOL 1.38 6TH TSP

-8.78 6TH TSP 41 92 05/94 RF0 Bobbin No!

0.62 10TH TSP

+25.89 F/L 05/94 RF0 Bobbin 001 26 0.42 9TH TSP

-1.25 F/L 05/94 RF0 C/L Special Int VOL 0.37 9TH TSP

-18.81 9TH TSP 05/94 RF0 C/L Special Int VOL 1.55 9TH TSP 17.80 9TH TSP 42 26 05/94 RF0 Bobbin 001 38 1.19 2AVB

+10.48 F/L 05/94 RF0 U-Bend VOL 1.56 2AVB

+9.21 2AVB 42 51 05/94 RF0 Bobbin 001 35 0.94 11TH TSP

+30.54 F/L 05/94 RF0 C/L Special Int VOL 1.17 10TH TSP

-14.18 10TH TSP 42 68 05/94 RF0 Bobbin ADI 4.2712TH TSP

+20.41 F/L 05/94 RF0 C/L Special Int VOL 1.03 12TH TSP

+19.41 12TH TSP 42 80 05/94 RF0 Bobbin 001 16 0.83 11TH TSP

+1.07 F/L 42 84 05/94 RF0 Bobbin 001 10 1.53 2ND TSP

+3.77 F/L 05/94 RF0 Bobbin ODI 26 0.34 STH TSP

+36.89 F/L 42 87 05/94 RF0 Bobbin ADI 2.78 19TH TSP

+ 5. 75 F/L 05/94 RF0 Bobbin ADI 2.88 19TH TSP

+8.46 F/L 05/94 RF0 C/L Special Int VOL 0.39 19TH TSP

+5.42 19TH TSP 42 89 05/94 RF0 Bobbin 001 30 0.46 7TH TSP

+21.01 F/L 42 90 05/94 RF0 Bobbin 001 28 0.73 14TH TSP

+5.61 F/L 05/94 RF0 C/L Special Int VOL 0.39 14TH TSP

+5.19 14TH TSP 43 22 05/94 RF0 Bobbin 001 17 0.93 1ST TSP

+4.31 F/L 43 23 05/94 RF0 Bobbin 001 12 1.32 7TH TSP

+14.16 F/L 05/94 RFO H/L Special Int VOL 0.53 7TH TSP

+7.09 TTH TSP 05/94 RF0 H/L Special Int VOL 0.91 7TH TSP

+13.92 7TH TSP 43 29 05/94 RF0 Bobbin 001 8

3.99 1ST TSP

+7.07 F/L 05/94 RF0 Bobbin 001 8

1.21 12TH TSP

+13.46 F/L 05/94 RF0 Bobbin 001 13 0.68 11TH TSP

+23.37 F/L 05/94 RF0 Bobbin 001 13 1.60 16TH TSP

+9.53 F/L 43 45 05/94 RF0 Bobbin NQI 0.76 11TH TSP

+9.65 F/L 05/94 RF0 C/L Special Int VOL 0.74 11TH TSP

+10.30 11TH TSP 43 55 05/94 RF0 Bobbin 001 26 0.44 6TH TSP

-0.83 F/L 05/94 RF0 Bobbin 001 3

1.72 11TH TSP

+34.63 F/L 05/94 RF0 Bobbin 001 8

1.69 11TH TSP

+20.65 F/L 05/94 RF0 Bobbin ODI 26 0.75 16TH TSP

+9.09 F/L 05/94 RF0 H/L Special lh! VOL 1.23 6TH TSP

-0.89 6TH TSP 05/94 RF0 C/L Special Int VOL 0.54 11TH TSP

+20.28 10TH TSP 05/94 RF0 C/L Special Int VOL 0.66 16TH TSP

+9.68 16TH TSP 05/94 RF0 C/L Special Int VOL 0.85 11TH TSP

+34.22 10TH TSP 43 66 05/94 RF0 Bobbin ODI 24 0.26 6TH TSP

+31.81 F/L 43 68 05/94 RF0 Bobbin NQI 0.19 10TH TSP

+29.76 F/L 43 71 05/94 RF0 Bobbin ADI 2.83 3RD TSP

+6.S4 F/L 05/94 RF0 Bobbin ADI 5.86 1ST TSP

+23.63 F/L 05/94 RF0 H/L Special Int VOL 1.39 3RD TSP

+6.90 3RD TSP 05/94 RF0 H/L Special int VOL 1.80 1ST TSP

+24.65 1ST TSP 43 82 05/94 RF0 Bobbin ADI 5.35 4AVB

  1. 12.80 F/L 05/94 RF0 U-Bend VOL 0.46 4AVB

+12.64 9TH TSP 43 86 05/94 RF0 Bobbin 001 7

2.08 12TH TSP

+9.76 F/L 05/94 RF0 Bobbin ODI B

1.56 12TH TSP

+1.65 F/L 05/94 RF0 Bobbin 001 9

1.66 12TH TSP

+11.10 F/L 05/94 RF0 Bobbin 001 12 1.31 12TH TSP

+1.01 F/L

eeeeee**********************

BWNS TUBAN 11 (Version 2.0) 06/17/1994 06:29:03 i

eeeeeeeeeee*****************

Catawba Nuclear Station

  • Unit Two S/G C 05/94 RF0 Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U Bend Page 24 of 27 S/G C - ATTACHMENT #3 INDICATIONS OF IMPERFECTIONS RDW COL DUTAGE TEST TYPE INO %TW VOLTS LOCATION EXTENT 1 05/94 RF0 Bobbin 001 19 1.57 12TH TSP

+11.83 F/L 05/94 RF0 Bobbin 001 19 1.86 12TH TSP

+10.44 F/L 05/94 RF0 Bobbin ADI 1.43 13TH TSP

+25.95 to +41.19 F/L 05/94 RF0 C/L Special Int VOL 0.44 12TH TSP

-4.19 to

-1.74 12TH TSP 43 89 05/94 RF0 Bobbin NQI 0.35 11TH TSP

+25.89 F/L 44 23 05/94 RF0 Bobbin WAR 7

0.38 4AVB

+0.00 F/L 05/94 RF0 Bobbin WAR 11 0.61 3AVB

+0.00 F/L 05/94 RF0 Bobbin WAR 13 0.78 1AVB

+0.00 F/L 44 37 05/94 RF0 Bobbin 001 7

0.95 91H TSP

-0.57 F/L 44 50 05/94 RF0 Bobbin 001 18 0.53 9TH TSP

-0.68 F/L 44 54 05/94 RF0 H/L Tubesheet VOL 0.99 TTS HL

+0.02 TTS HL 44 67 05/94 RF0 Bobbin 001 3

0.30 12TH TSP

+28.21 F/L 44 71 05/94 RF0 Bobbin ADI 1.95 18TH TSP

+2.46 F/L 05/94 RF0 C/L Special Int VOL 0.45 18TH TSP

+2.44 18TH TSP 44 76 05/94 RF0 Bobbin 001 4

1.11 14TH TSP

+5.96 F/L 44 80 05/94 RF0 Bobbin 001 9

0.61 6TH TSP

+21.56 F/L 05/94 RF0 H/L Special Int VOL 0.56 6TH TSP

+21.78 6TH TSP 44 81 05/94 RF0 Bobbin WAR 26 1.28 3AVB

+0.00 F/L 05/94 RF0 Bobbin WAR 28 1.53 2AVB

+0.00 F/L 05/94 RF0 U Bend VOL 0.19 3AVB

+0.00 9TH TSP 05/94 RF0 U Bend VOL 0.25 2AVB

+0.00 9TH TSP 44 86 05/94 RF0 Bobbin 001 17 0.50 11TH TSP

+30.62 F/L 44-87 05/94 RF0 Bobbin 001 9

0.33 10TH TSP

+10.53 F/L 05/94 RF0 Bobbin 001 9

2.06 18TH TSP

+13.68 F/L 05/94 RF0 Bobbin 001 19 0.34 11TH TSP

+40.19 F/L 44 88 05/94 RF0 Bobbin ADI 1.94 10TH TSP

+43.50 F/L 05/94 RFO C/L Special Int VOL 0.30 10TH TSP

+39.76 10TH TSP 44 90 05/94 RF0 Bobbin 001 3

0.50 14TH TSP

+12.86 F/L 44 91 05/94 RF0 Bobbin ODI 28 0.27 10TH TSP

+26.14 F/L 05/94 RF0 C/L Special Int VOL 1.14 9TH TSP

-17.69 97H TSP 44 v2 05/94 RF0 Bobbin ADI 2.88 TTS HL

+3.88 F/L 45 37 05/94 RF0 Bobbin 001 36 1.62 1ST TSP

+25.27 F/L 05/94 RF0 H/L Special Int VOL 0.44 2ND TSP

-4.30 2ND TSP 05/94 RF0 H/L Special Int VOL 1.33 2ND TSP

-3.23 2ND TSP 45 41 05/94 RF0 Bobbin ODI 10 1.39 13TH TSP

+34.77 F/L 05/94 RF0 Bobbin 001 17 1.54 13TH TSP

+21.74 F/L 05/94 RF0 Bobbin 001 36 0.99 13TH TSP

+31.50 F/L 05/94 RF0 C/L Spt.at Int VOL 0.20 12TH TSP

-9.17 12TH TSP 05/94 RFC C/L Specist Int VOL 0.35 12TH TSP

-11.96 12TH TSP 45 46 05/94 RF0 Bobbin No!

0.22 8TH TSP

-1.66 F/L 45 50 05/94 RF0 Bobbin 001 8

1.65 17TH TSP

+25.78 F/L 45 51 05/94 RF0 Bobbin 001 4

1.52 3AVB

+27.47 F/L 05/94 RF0 Bobbin 001 6

1.2710TH TSP

+17.27 F/L 05/94 RF0 C/L Specist Int VOL 1.00 10TH TSP

+17.70 10TH TSP 45 56 05/94 RF0 Bobbin 001 10 0.58 3AVB

-20.07 F/L 45 59 05/94 RF0 Bobbin No!

1.80 4AVB

-1.54 F/L 05/94 RF0 Bobbin WAR 15 0.91 3AVB

+0.00 F/L 05 / 94 RF0 Bobbin NQI 0.2711TH TSP

+17.98 F/L 05/94 RF0 U-Bend VOL 0.48 2AVB

+0.00 9TH TSP 05/94 RTJ U Bend VOL 0.53 4AVB

-1.54 9TH TSP 05/94 RFo U-Bend VOL 0.84 3AVB

+0.00 97H TSP 05/94 RF0 Bobbin 001 27 2.75 13TH TSP

+6.67 F/L 05/94 RF0 Bobbin 001 28 0.44 11TH TSP

+18.35 F/L 05/94 RF0 Bobbin 001 34 0.86 13TH TSP

+24.14 F/L 05/94 RFC C/L Special Int VOL 0.20 11TH TSP

+17.47 11TH TSP 05/94 RF0 C/L Special Int VOL 0.67 13TH TSP

+22.74 13TH TSP 05/94 RF0 C/L Special Int VOL 1.44 13TH TSP

+6.34 13TH TSP 45 61 05/94 RF0 Bobbin 001 34 0.58 13TH TSP

+18.17 F/L 05/94 RFU C/L Special Int VOL 0.60 13TH TSP

+18.07 13TH TSP 45 62 05/94 RTO Bobbin 001 29 1.38 2ND TSP

+12.33 F/L 45 67 05/94 RF0 Bobbin 001 14 0.97 2ND TSP

+14.18 F/L 45 70 05/94 RF0 Bobbin 001 30 0.84 1ST TSP

+8.02 F/L 45 73 05/94 RF0 Bobbin ADI 2.90 4AVB

+18.01 F/L 05/94 RF0 Bobbin A0!

4.81 4AVB

+16.27 F/L 05/94 RF0 Bobbin ADI 3.02 4TH TSP

+28.28 F/L 05/94 RF0 U Bend VOL 0.85 4AVB

+18.01 9TH TSP

eeeeeeeeee...........

...e*

BWNS TUBAN !! (Version 2.0) 06/17/1994 06:29:03 e***************************

Catawba Nuclear Station - Unit TWo S/G C 05/94 RF0 Bobbin,C/L Special Interett,H/L Special Interest,H/L Tubesheet,U-Bend Page 25 of 27 S/G C ATTACHMENT #3 INDICATIONS OF IMPERFECTIONS ROW COL QUTAGE TEST TYPE IND %TW VOLTS LOCATION EXTENT 1 05/94 RF0 U-Bend VOL 0.95 4AVB

+16.27 97H TSP 05/94 RF0 N/L Special Int VOL 1.45 4TH TSP

+28.94 4TH TSP i

45 76 05/94 RF0 Bobbin 001 5

0.58 BTH TSP

-0.69 F/L 45 77 05/94 RF0 Bobbin 001 14 1.06 TTS-HL

+1.77 F/L 45 78 05/94 RF0 Bobbin 001 6

0.89 2AVB

-1.00 F/L 45 86 05/94 RF0 Bobbin 001 18 1.44 3AVB

+2.83 F/L 05/94 RF0 Bobbin 001 3

2.02 11TH TSP

+16.82 F/L 45 88 05/94 RF0 Bobbin 001 9

0.50 7TH TSP

+37.02 F/L 05/94 RF0 Bobbin 001 9

0.56 TTH TSP

+39.06 F/L 05/94 RF0 Bobbin 001 10 0.97 2WD TSP

+18.17 F/L 46 16 05/94 RF0 Bobbin WAR 10 0.58 4AVB

+0.00 F/L 05/94 RF0 Bobbin WAR 17 1.08 3AVB

+0.00 F/L 05/94 RF0 U-Bend VOL 0.33 3AVB

+0.00 3AVB 05/94 RF0 Bobbin 001 6

0.65 9TH TSP

-0.59 F/L 46 28 05/94 RF0 Bobbin 001 3

0.81 11TH TSP

+31.28 F/L 46 31 05/94 RF0 Bobbin 001 14 0.46 13T,; TSP

+2 19 F/L 46 34 05/94 RF0 Bobbin 001 27 1.78 12TH TSP

+12.01 F/L 46 35 05/94 RF0 Bobbin 001 5

2.04 2AVB

+7.72 F/L 05/94 RF0 Bobbin 001 8 0.3712TH TSP

+11.50 F/L 46 41 05/94 RF0 Bobbin 001 12 1.02 7TH TSP

+5.34 F tL 46 47 05/94 RF0 Bobbin 001 11 0.68 13TH TSP

+4.92 P/L 05/94 RF0 Bobbin 001 16 1.26 13TH TSP

+10.30 F/L 05/94 RFC Bobbin 001 32 1,67 13TH TSP

+18.16 F/L 46 49 05/94 RF0 Bobbin 001 16 0.38 11TH TSP

+31.70 F/L 46 54 05/94 RF0 Bobbin 001 2

1.71 11TH TSP

+13.46 F/L 46 55 05/94 RF0 Bobbin NQI 0.67 BTH TSP

-1.40 F/L T

05/94 RF0 H/L Special Int VOL 0.63 BTH TSP

-1.32 8TH TSP 46 56 05/94 RF0 Bobbin WAR 14 0.85 4AVB

+0.00 F/L 46 65 05/94 RF0 Bobbin 001 25 0.34 TTH TSP

+4.19 F/L 46 73 05/94 RF0 Bobbin 001 5

0.36 9TH TSP

+0.49 F/L 05/94 RF0 Bobbin 001 2

0.62 13TH TSP

+9.44 F/L 46 75 05/94 RF0 Bobbin 001 4

2.02 5TH TSP

+13.23 F/L 05/94 RF0 Bobbin 001 11 0.93 13TH TSP

+8.87 F/L 46 76 05/94 RF0 Bobbin 001 3

0.62 9TH TSP

+0.40 F/L 46 87 05/94 RF0 Boboin 001 41 0.45 10TH TSP

+16.76 F/L 05/94 RF0 C/L Special Int 001 40 0.15 10TH T$P

+15.80 10TH TSP c

47 42 05/94 RF0 Bobbin ODI 19 4.81 4AVB

+7.78 F/L 05/94 RF0 Bobbin DDI 23 0.52 1STH TSP

+32.57 F/L 47 47 05/94 RF0 Bobbin ODI 4

1.25 15TH TSP

+31.10 F/L 05/94 RF0 Bobbin 001 6

0.49 11TH TSP

+28.09 F/L t

47 49 05/94 RF0 Bobbin 001 33 1.22 12TH TSP

+7.00 F/L 47 55 05/94 RF0 Bobbin No!

0.71 1ST TSP

+15.32 F/L 05/94 RF0 N/L Special Int VOL 1.74 1ST TSP

+14.83 1ST TSP 47 60 05/94 RF0 Bobbin 001 17 1.05 4AVB

+30.24 F/L 47 75 05/94 RF0 Bobbin NQI 0.27 BTH TSP 0.64 F/L 05/94 RF0 Bobbin 001 10 0.54 9Th TSP

-0.62 F/L 47 (6 05/94 RF0 Bobbin NQI 0.27 BTH TSP

-0.58 F/L 05/94 RF0 Bobbin 001 15 0.64 91H TSP

-0.65 F/L 47 81 05/94 RF0 Bobbin 001 12 0.43 87H TSP

-0.55 F/L 47 82 05/94 RF0 Bobbin 001 8

1.40 ISTH TSP

+26.92 F/L

- 47 87 05/94 RF0 Bobbin ADI 4.85 2ND TSP

+32.74 F/L 07/94 RF0 H/L Special Int VOL 2.26 3RD TSP

-2.60 3RD TSP 48 29 05/94 RF0 Bobbin 001 4

1.01 13TH TSP

-2.03 F/L 05/94 RF0 Bobbin 001 17 1.07 10TH TSP

-3.49 F/L 05/94 RF0 Bobbin ODI 29 0.63 1STH TSP

+21.21 F/L 48 32 05/94 RF0 Sobbin 001 8

1.63 STN TSP

+35.83 F/L 48 35 05/94 RF0 Bobbin 001 11 1.18 18TH TSP

+3.32 F/L 48 37 05/94 WF0 Bobbin ODI 12 1.51 2AVB

-5.62 F/L 48 45 05/94 RF0 Bobbin ADI 5.28 STH TSP

+13.46 F/L 05/94 RF0 Bobbin ADI 3.30 13fH TSP 3.69 F/L 05/94 RF0 H/L Special Int VOL 1.03 STN TSP

+13.21 STH TSP 05/94 RF0 C/L Special Int VOL 0.7513fH TSP

-5.45 13fH TSP 48 48 05/94 RF0 Bobbin A01 5.08 13TH TSP

+18.15 F/L 05/94 RF0 Bobbin 001 6 0.7217TH TSP

+20.45 F/L 05/94 RF0 C/L Special Int VOL 0.21 17TH TSP

+22.95 177H TSP 05/94 RF0 C/L Special Int VOL 1.07 13fH TSP

+20.45 13fH TSP

BWN5 TUBAN II (Version 2.0) 06/17/1994 06:29:03 r

Catawba Nuclear Station - Unit Two

.........++......***********

S/G C 05/94 RF0 Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U-Bend eenee............. *********

Page 26 of 27 S/G C - ATTACHMENT #3 INDICATIONS OF IMPEkFECTIONS ROW COL OUTACE TEST TYPE IND %TW VOLTS LOCATION EXTENT 1 48 52 05/94 RF0 Bobbin No!

0.31 15TH TSP

+29.23 F/L 05/94 RF0 Bobbin 001 16 0.66 15TH TSP

+29.48 F/L 05/94 RF0 C/L Special Int VOL 0.90 13TH TSP

-7.23 13TH TSP 48 53 05/94 RFO Bobbin NQI 0.95 18TH TSP

+10.70 F/L 05/94 RFJ Bobbin ODI 1

0.67 STH TSP

-3.37 F/L 05/94 RF0 Bobbin ODI 8

1.46 4TH TSP

+10.73 F/L 05/94 RF0 Bobbin ODI 21 3.32 4TH TSP

+10.35 F/L 05/94 RF0 C/L Special Int VOL 0.3717TH TSP 9.96 17TH TSP 48 54 05/94 RF0 Bobbin WAR 13 0.82 3AVB

+0.00 F/L 48 59 05/94 RF0 Bobbin 001 14 1.03 BTH TSP

+3.54 F/L 05/94 RF0 Bobbin 001 31 1.00 STH TSP

+4.09 F/L 05/94 RF0 U-Bend VOL 0.21 BTH TSP

+2.71 BTH TSP l

05/94 RF0 U-Bend VOL 0.69 81H TSP

-0.84 BTH TSP 05/94 RF0 U-Bend VOL 0.80 STH TSP

+4.10 BTH TSP 05/94 RF0 U-Bend VOL 1.20 8TH TSP

+3.40 BTH TSP 48 60 05/94 RF0 Bobbin No!

0.27 13TH TSP

+31.48 F/L 05/94 RF0 C/L Special Int VOL 0.23 13TH TSP

+18.58 13TH TSP 48 61 05/94 RF0 Bobbin NQI 1.00 4AVB

+31.09 F/L 05/94 RF0 Bobbin ODI 13 1.35 87H TSP

+4.55 F/L 05/94 RF0 U Bend VOL 0.63 8TH TSP

+4.61 8TH TSP 48 63 05/94 RF0 Bobbin 001 12 1.03 BTH TSP

+4.21 F/L 48 67 05/94 RF0 Bobbin ODI 18 1.03 4AVB

+30.35 F/L 05/94 RF0 Bobbin No!

0.43 STH TSP

+3.63 F/L 48 68 05/94 RF0 Bobbin ODI 6

1.00 8TH TSP

+4.34 F/L 05/94 RF0 U-Bend VOL 0.37 BTH TSP

+3.99 BTH TSP 48 72 05/94 RF0 Bobbin NOI 0.45 BTH TSP

+3.25 F/L 05/94 RF0 U-Bend VOL 0.64 BTH TSP

+3.58 8TH TSP 48 75 05/94 RF0 Bobbin ADI 2.73 6TH TSP

+21.94 F/L 05/94 RF0 H/L Special Int VOL 0.50 6TH TSP

+21.53 6TH TSP 48 76 05/94 RF0 Bobbin 001 11 1.44 15fH ISP

+7.13 F/L 05/94 RF0 Bobbin 001 14 3.39 10TH TSP

+3.74 F/L 05/94 RF0 C/L Special Int VOL 0.62 15fH TSP

+ 7. 3 7 15TH TSP 48 86 05/94 RF0 Bobbin ODI 7

0.95 18TH TSP

+13.59 F/L 05/94 RF0 Bobbin 001 9

0.99 13TH TSP

+7.36 F/L 05/94 RF0 Bobbin 001 13 3.21 11TH TSP

+15.38 F/L 05/94 RF0 C/L Special Int VOL 0.30 13TH TSP

+7.35 13TH TSP 05/94 RF0 C/L Special Int VOL 0.57 18TH TSP

+13.69 18TH TSP i

05/94 RF0 C/L Special Int VOL 1.17 181H TSP

+5.04 187H TSP 05/94 RF0 C/L Special Int VOL 1.22 11TH TSP

+15.50 11TH TSP 49 39 05/94 RF0 Bobbin ADI 10.15 STH TSP

+5.67 F/L 05/94 RF0 H/L Special Int VOL 0.74 STH TSP

+5.88 STH TSP 05/94 RF0 H/L Spectat Int VOL 1.04 STH TSP

+7.06 STH TSP 49 47 05/94 RF0 Bobbin ODI 4

1.06 13TH TSP

-5.97 F/L i

05/94 RF0 C/L Special Int VOL 0.80 13TH TSP

-4.74 13TH TSP 05/94 RF0 C/L Special Int VOL 0.89 13TH TSP

-7.79 13TH TSP 05/94 RF0 C/L Specist Int VOL 1.48 137H TSP

-7.04 13fH ISP 1

49 55 05/94 RF0 Bobbin 001 16 0.54 7TH TSP

+40.84 F/L 05/94 RF0 H/L Special Int VOL 1.12 BTH TSP

-7.73 8TH TSP 49 59 05/94 RF0 Bobbin ODI 9

1.99 4AVB 23.83 F/L 05/94 RF0 Bobbin 001 18 1.60 11TH TSP

+36.00 F/L 49 63 05/94 RF0 Bobbin ADI 3.26 15fH TSP

+33.55 F/L 05/94 RF0 C/L Special Int VOL 0.60 15TH TSP

+33.57 iSTH TSP 49 65 05/94 RF0 Bobbin ADI 3.69 4AVB

+23.57 F/L 05/94 RF0 Bobbin ADI 2.04 STH TSP

+32.75 F/L 05/94 RF0 U-Bend VOL 0.88 4AVB

-22.84 9TH TSP l

05/94 RF0 Bobbin ODI 5

0.62 11TH TSP

+16.22 F/L i

05/94 RF0 H/L Special Int VOL 1.36 6TH TSP

-7.05 6TH TSP 49 68 05/94 RF0 Bobbin ADI 2.56 12TH TSP

+21.12 F/L 49 70 05/94 RF0 Bobbin 001 11 0.6217TH TSP

+10.55 F/L 49 75 05/94 RF0 Bobbin ODI 13 0.43 9TH TSP

-0.79 F/L 49 76 05/94 RF0 Bobbin WAR 30 1.98 1AVB

+0.00 F/L 49 81 05/94 RF0 Bobbin ODI 13 0.8715TH TSP

+26.70 F/L 05/94 RF0 C/L Special Int VOL 0.58 15TH TSP

+26.77 15TH TSP 49 84 05/94 RF0 Bobbin ADI 2.56 13TH TSP

+18.66 F/L l

05/94 RF0 C/L Special Int VOL 0.55 13TH TSP

+18.33 13TH TSP

e**************************

BWNS TUBAN !! (Version 2.0) 06/17/1994 06:29:03 Catawba Nuclear Station - Unit Two eeeeee...*****************

S/G C 05/94 RF0 Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U-Bend Page 27 of 27

$/G C - ATTACHMENT #31NDICAT10NS OF IMPERFECTIONS ROW COL DUTAGE TEST TYPE IND %TW VOLTS LOCATION EXTENT 1 Total Indications Found = 1715 Total Tubes Found = 750 t

i 1

i

A ATTACIIMENT 4

BwNS TUBAN 11 (version 2.0) 06/17/1994 06:39:09

    • eee* *eeeeeee*************

Catawba Nuclear Station - Unit Two

.**.....e****.e**e....

Sfc p

        • e....**.****************

05/94 RF0 Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U Bend

  • ee............************

Page 1 of 32 S/G D - ATTACHMENT #4 INDICATIONS OF IMPERFECTIONS ROW COL DUTAGE TEST TYPE IND %TW VOLTS LOCATION EXTENT 1 1 9 05/94 RF0 S(44 J n ADI 5.75 STH TSP

+14.02 8TH TSP 05/94 RF0

  • t cpecial Int VOL 1.07 STH TSP

+12.69 STH TSP 1 30 05/94 RF0 0 Jin ADI 4.83 7TH TSP

+ 17.05 BTH TSP 05/94 RF0 Buobin ADI 5.17 TTH TSP

+11.86 BTH TSP 05/94 RF0 H/L Special Int VOL 0.91 7TH TSP

+16.11 7TH TSP 05/94 RIO H/L Special Int VOL 1.51 7TH TSP

+11.09 7TH TSP 1 32 05/94 RF0 Bobbin 001 8

1.25 13TH TSP

+21.06 8TH TSP 1 34 05/94 RF0 Bobbin ADI 5.56 3RD TSP

+29.16 87H TSP 05/94 RF0 Bobbin NQI 0.71 IST TSP

+19.30 8TH TSP 05/94 RF0 H/L Special Int VOL 0.62 4TH TSP

-6.97 4TH TSP 05/94 RF0 H/L Special Int VOL 0.69 2ND TSP

-8.51 2ND TSP 1 37 05/94 RF0 Bobbin DDI 24 0.53 12TH TSP

+33.31 DTH TSP i

05/94 RF0 C/L Specist Int VOL 0.84 12TH TSP

+32.99 11TH TSP 1 59 05/94 RIO Bobbin NQI 0.70 12TH TSP

+18.12 STH TSP 05/94 RF0 C/L Specint Int VOL 0.81 12TH TSP

+18.12 12TH TSP 1 65 05/94 RF0 Bobbin ADI 3.6712TH TSP

+29.65 STH TSP 05/94 RF0 Bobbin ADI 10.!2 10TH TSP

+8.25 BTH TSP 05/94 RF0 Bobbin 001 4

6.91 156 TSP

+12.89 BTH TSP 05/94 RF0 H/L Tubesheet VOL 0.91 TTS HL

+1.51 TTS HL 05/94 RF0 H/L Special Int VOL 0.29 1ST TSP

+12.63 END TSP 05/94 RF0 C/L Special Int VOL 0.39 12TH TSP

+10.85 11TH TSP 05/V4 RIO C/L Special Int VOL 0.59 12TH TSP

+28.82 11TH TSP 05/94 RF0 C/L Special Int VOL 0.78 10TH TSP

+8.25 10TH TSP 1 67 05/94 RF0 Bobbin ADI 4.32 4TH TSP

+4.48 8TH TSP 05/94 RTO H/L $pecial Int VOL 0.35 4TH TSP

+4.07 4TH TSP 05/94 RF0 H/L Special Int VOL 0.45 4TH TSP

+6.57 4TH TSP 1 80 05/94 RTO Bobbin 001 11 3.32 6TH TSP

+ 9.13 8TH TSP 1 94 05/94 RTO Bobbin 001 23 1.10 7TH TSP

+27.88 8TH TSP 1 95 05/94 RF0 Bobbin ADI 6.50 STH TSP

+27.07 8TH TSP 05/94 RF0 H/L Special Int VOL 0.30 STH TSP

+26.77 STH TSP 1 104 05/94 RF0 Bobbin ADI B.92 1ST TSP

+5.46 87H TSP 05/94 RF0 H/L Special Int VOL 1.19 1ST TSP

+ 7. 49 1ST TSP 05/94 RF0 H/L Special Int VOL 1.69 IST TSP

+4.85 1ST TSP 1 106 05/94 RF0 Scbbin 001 23 3.79 7TH TSP

+30.21 8TH TSP 2 2 05/94 RF0 Bobbin ADI 5.71 1BTH TSP + 28. 75 STH TSP 05/94 RTO C/L Specint Int VOL 0.91 16TH TSP

-7.28 16TH TSP 2 3 05/94 RF0 Bobbin ADI 4.13 4TH TSP

+9.35 8TH TSP 05/v4 RF0 Bobbin NQ1 1.43 3RD TSP

+ 27.33 STH TSP 05/94 RF0 Bobbin 001 34 0.66 STH TSP

+31.43 STH TSP 05/94 RF0 Bobbin 001 29 1.11 131H TSP

+25.63 8TH TSP 05/94 RF0 H/L Special Int VOL 0.58 4TH TSP

+8.03 4TH TSP 05/94 RF0 H/L Special Int VOL 0.90 4TH TSP

-8.07 4TH TSP 2 7 05/94 RF0 Bobbin NQI 0.98 7TH TSP

+17.09 8TH TSP 05/94 RTO Bobbin NQI 1.05 7TH TSP

+15.86 STH TSP 2 38 05/94 RF0 Bobbin 001 7

0.89 16TH TSP

+24.37 BTH TSP 2 42 05/94 RF0 Bobbin ODI 10 1.95 2ND TSP

+2.55 BTH TSP 2 45 05/94 RF0 Bobbin 001 28 2.74 IST TSP

+25.08 BTH TSP 2 61 05/94 RF0 Bobbin ADI 6.81 4TH TSP

+33.81 STH TSP 2 72 05/94 RTO Bobbin ADI 5.87 16TH TSP

+29,11 BTH TSP 05/94 RF0 Bobbin 001 11 0.99 51H TSP

+14.74 8TH TSP 05/94 RF0 H/L Special Int VOL 1.36 STH TSP

+14.08 STH TSP 05/94 RF0 C/L Special Int VOL 0.79 16TH TSP

+29.11 16TH TSP 2 84 05/94 RF0 Bobbin 001 7

1.25 4TH TSP

+36.29 BTH TSP 2 91 05/94 RF0 Bobbin 001 33 1.26 7TH TSP

+23.68 BTH TSP 2 108 05/94 RF0 Bobbin 001 16 0.66 11TH TSP

+33.19 BTH TSP 2 113 05/94 RF0 Bobbin ADI 3.86 16TH TSP

+32.57 STH TSP 05/94 RF0 C/L Special Int VOL 0.65 16TH TSP

+32.57 16TH TSP 3 2 05/94 RF0 Bobbin NQI 2.79 BTH TSP

+0.26 BTH TSP 05/94 RF0 Bobbin No!

0.46 10TH TSP

+36.62 BTH TSP 05/94 RF0 C/L Special Int YOL 0.41 9TH TSP 4.70 9TH ISP 05/94 RF0 C/L Special Int VOL 0.42 9TH TSP

-5.40 9TH TSP 05/94 RF0 C/L Special int VOL 1.62 97H TSP 4.60 9TH TSP 05/94 RF0 H/L Special int VOL 0.58 8TH 1SP

-4.15 87H TSP 05/94 RF0 H/L Special Int VOL 1.01 8TH TSP

-3.02 81H TSP 3 4 05/94 RF0 Bobbin 001 11 0.78 7TH TSP

+36.85 8TH TSP 3 6 05/94 RF0 Bobbin DDI 33 0.43 10TH TSP

+19.04 BTH TSP e

l BVNS TUBAN II (Version 2.0) 06/17/1994 06:39:09 eeeeeeeeeeeeeeeeeeeeeeeeeee.

Catawba Nuclear Station - Unit Two e......*********************

S/G D i

eeeeeeeeeeeeeee*************

05/94 RF0 Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U-Bend e.............e*************

Page 2 of 32 S/G 0 - ATTACHMENT #4 INDICATIONS OF IMPERFECTIONS ROW COL DUTAGE TEST TYPE IND %TW VOLTS LOCATION EXTENT 1 3 7 05/94 RF0 Bobbin NQI 0.68 10TH TSP + 29.5 7 BTH TSP 05/94 RF0 Bobbin 001 3

0.69 7TH TSP

+30.22 BTH TSP 3 8 05/94 RF0 Bobbin NOI 0.42 12TH TSP

+32.81 BTH TSP 05/94 RF0 Bobbin DDI 9

1.62 STH TSP

+32.82 87H TSP 3 9 05/94 RF0 Bobbin ADI 9.00 10TH TSP

+35.00 8TH TSP l

05/94 RF0 C/L Special Int VOL 2.10 10TH TSP

+36.45 10TH TSP 3 13 05/94 RF0 Bobbin 001 15 2.20 177H TSP

+12.82 BTH TSP 3 24 05/94 RF0 Bobbin ADI 6.67 2ND TSP

+26.21 BTH TSP 05/94 RF0 Bobbin ODI 11 1.24 18TH TSP

+8.30 8TH TSP 05/94 RF0 H/L Special Int VOL 0.73 3RD TSP

-9.59 3RD TSP 3 29 05/94 RF0 Bobbin ADI 7.78 7TH TSP

+10.62 8TH TSP 05/94 RF0 Bobbin ADI 6.61 12TH TSP

+35.91 BTH TSP 05/94 RTO Bobbin NQ1 0.42 10TH TSP

+15.31 8TH TSP 05/94 RF0 H/L Special Int VOL 0.79 7TH TSP

+10.24 TTH TSP 05/94 RF0 C/L Special Int VOL 0.73 11TH TSP 6.01 11TH TSP 05/94 RF0 C/L Specist Int VOL 0.76 10TH TSP

+14.87 10TH TSP 3 31 05/94 RF0 Bobbin ADI 3.60 STH TSP

+24.84 BTH TSP 05/94 RF0 H/L Special Int VOL 0.47 STH TSP

+23.73 5(H 1SP 3 37 05/94 RF0 Bobbin 001 20 1.82 7TH TSP

+24.68 BTH TSP 1

3 53 05/94 RF0 Bobbin 001 27 3.52 3RD TSP

+9.12 STH TSP 3 58 05/94 RF0 Bobbin ADI 3.62 16TH TSP

+13.09 BTH TSP l

3 64 05/94 RF0 Bobbin ADI 7.92 13fH TSP

+18.06 BTH TSP l

05/94 RF0 C/L Special Int VOL 0.64 13TH TSP

+18.06 13TH TSP l

3 70 05/94 RF0 Bobbin ADI 3.13 11TH TSP

+33.67 BTH TSP 05/94 RF0 C/L Special Int VOL 0.52 10TH TSP

-9.94 10TH TSP 3 75 05/94 RfD Bobbin 001 15 0.50 7TH TSP

+20.73 8TH TSP 3 76 05/94 RF0 Bobbin ADI 2.84 12TH TSP

+5.49 BTH TSP 05/94 RF0 Bobbin ADI 4.20 10TH TSP

+16.61 8TH TSP 05/94 RF0 Bobbin 001 19 1.42 7TH TSP

+14.96 BTH TSP 05/94 RF0 C/L Special Int VOL 0.56 10TH TSP

+17.83 10TH TSP 05/94 RF0 C/L Special int VOL 0.59 12TH TSP

+5.49 12TH TSP 3 89 05/94 RF0 Bobbin ADI 9.18 10TH TSP

+41.64 BTH TSP 05/94 RTO C/L Special Int VOL 1.65 97H TSP

-4.59 9TH TSP 3 101 05/94 RF0 Bobbin ADI 2.84 14TH TSP

+4.76 8TH TSP 05/94 RF0 Bobbin ADI 4.33 12TH TSP

+14.21 BTH TSP 05/94 RF0 Bobbin ODI 2

1.16 14TH TSP

+11.43 8TH TSP 05/94 RF0 Bobbin 001 15 0.73 14TH TSP

+12.52 BTH TSP 05/94 RF0 C/L Specia! Int VOL 0.45 12TH TSP

+14.76 12TH TSP 05/94 RF0 C/L Special Int VOL 0.59 14TH TSP

+4.76 14TH TSP 3 105 05/94 RF0 Bobbin ADI 2.51 15TH TSP

+13.41 8TH TSP 05/94 RF0 Bobbin 001 !?

0.50 17TH TSP

+2.90 8TH TSP 05/94 RF0 C/L Speclat Int VOL 1.32 14TH TSP

-5.04 14TH TSP 3 109 05/94 RF0 Bobbin 001 7

1.10 12TH TSP

+16.77 BTH TSP 05/94 RF0 Bobbin 001 7

1.29 12TH TSP

+17.86 81H TSP 3 112 05/94 RF0 Bobbin ADI 6.58 18TH TSP

+13.83 BTH TSP 05/94 RF0 C/L Special Int VOL 0.3417TH TSP

-4.70 17TH TSP 4 1 05/94 RF0 Bobbin NOI 0.23 7TH TSP

+39.79 STH TSP 05/94 RF0 Bobbin NOI 0.25 7TH TSP

+36.08 8TH TSP 05/94 RF0 Bobbin ODI 4

0.60 7TH TSP

+34.20 BTH TSP 05/94 RF0 Bobbin DDI 12 1.03 7TH TSP

+41.01 8TH TSP l

05/94 RF0 Bobbin 001 13 0.42 7TH TSP

+30.23 BTH TSP i

05/94 RF0 Bobbin 001 20 0.59 10TH TSP

+28.42 8tH TSP 4 2 05/94 RTO Bobbin ADI 0.79 7TH TSP

+23.23 BTH TSP 05/94 RF0 H/L Special Int VOL 0.54 7TH TSP

+23.20 71H TSP i

4 3 05/94 RF0 Bobbin ODI 22 3.14 BTH TSP

-4.81 8TH TSP 4 4 05/94 RF0 Bobbin 001 16 0.37 7TH TSP

+33.61 BTH TSP 05/94 RF0 Bobbin 001 23 0,41 71H TSP

+ 18.57 BTH TSP j

05/94 RF0 Bobbin 001 31 0.73 10TH TSP

+17.85 8TH TSP 4 5 05/94 RF0 Bobbin DDI 33 0.58 7TH TSP

+41.39 BTH TSP 4 8 05/94 RF0 Bobbin 001 9

0.70 STH TSP

+33.01 BTH TSP 4 9 05/94 RF0 Bobbin 001 9

0.94 STH TSP

+32. 64 8TH TSP 4 24 05/94 RF0 Bobbin ADI 1.77 2ND TSP

+26.53 BTH TSP 4 31 05/94 RF0 Bobbin ADI 6.76 18TH TSP

+5.98 BTH TSP 4 34 05/94 RF0 Bobbin ADI 3.99 12TH TSP

+19.51 8TH TSP 05/94 RF0 C/L Spectat Int VOL 0.45 12TH TSP

+19.35 12TH TSP 4 38 05/94 RF0 Bobbin ADI 3.46 17TH TSP

+0.03 BTH TSP

l eeeeeeeeeeeeeee*************

BWNS TUBAN 11 (Version 2.0) 06/17/1994 06:39:09 1

Catawba Nuclear Station Unit Two eseessesseeeeeeeeeeeeeeeeeee eeeeeeeeeeeeeeeeeeeeeeeeeeee gjg n

                                • b**********

05/94 Rr0 Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U Bend Page 3 of 32

$/G D ATTACHMENT #4 INDICATIONS OF IMPERFECTIONS ROW COL OUTAGE TEST TYPE IND %TW VOLTS LOCATION EXTENT 1 05/94 RfD Bobbin ADI 4.06171H ISP

+4.15 BTH TSP 05/94 RF0 C/L Special Int VOL 0.48 171H TSP

+4.50 171H TSP 05/94 RF0 C/L Special Int VOL 0.56171H TSP

+B.57 171H TSP 4 43 05/94 RF0 Bobbin ADI 1.99 151H TSP

+9.54 7TH TSP 05/94 RF0 Bobbin 001 35 2.94 3RD TSP

+9.84 BiH TSP 05/94 RF0 H/L 'pecial Int VOL 1.12 3RD TSP

+9.36 3RD TSP 05/94 RF0 C/L Special Int VOL 0.40 151H TSP

+9.36 15TH TSP l

4 51 05/94 RF0 Bobbin ADI 2.58 161H TSP

+5.97 8TH TSP 05/94 RF0 Bobbin ADI 4.35 16TH TSP

+5.81 81H TSP 05/94 RF0 C/L Special Int VOL 0.79 16TH TSP

+5.30 16TH TSP 4 53 05/94 RF0 Bobbin NQ1 1.67 3RD TSP

+12.64 BTH TSP 05/94 RF0 H/L Spectat Int VOL 1.00 3RD TSP

+12.76 3RD TSP 4 54 05/94 RF0 Bobbin ADI 1.00 STH TSP

+15.49 BTH TSP 05/94 RfD Bobbin ADI 1.30 STH TSP

+6.49 BTH TSP 05/94 RfD Bobbin ADI 2.11 STH ISP

+34.12 BTH TSP 05/94 RfD H/L Speclal Int VOL 0.99 STH TSP

+33.21 STH TSP 05/94 RF0 H/L Special Int VOL 1.53 STH TSP

+14.68 STH TSP 05/94 RF0 H/L Specist Int VOL 1.65 STH TSP

+5.92 STH TSP 4 65 05/94 RfD Bobbin ADI 4.46 15fH TSP

+8.71 to +13.33 BTH TSP 4 67 05/94 RfD Bobbin ADI 6.17 2ND TSP

+17.31 BTH TSP 05/94 RF0 H/L Special Int VOL 0.74 2ND TSP

+16.51 2ND TSP 4 68 05/94 RF0 Bobbin ADI 8.12 2ND TSP

+3.59 BTH ISP l

05/94 RF0 Bobbin 001 7

2.56 3RD TSP

+10.72 BTH TSP l

05/94 RF0 H/L Special Int VOL 0.86 ?ND TSP

+3.21 2ND TSP 4 75 05/94 RF0 Bobbin ODI 14 2.04 10TH ISP

+22.09 81H TSP 4 90 05/94 RfD Bobbin ADI 4.95 1ST TSP

+2.73 87H TSP 05/94 RFC M/L Special Int VOL 1.15 1ST ISP

+2.40 1ST TSP 4 93 05/94 RfC Bobbin 001 3

1.73 101H ISP

+32.48 BTH TSP 4 94 05/94 RF0 Bobbin NQI 0.63 3RD TSP

-1.35 81H ISP 05/94 RfD Bobbin NQ1 1.16 3RD TSP

+5.71 8TH ISP 05/94 RF0 Bobbin NQI 2.04 3RD iSP

+3.10 8TH TSP 05/94 RfD Bobbin 001 5

1.34 3RD TSP

+1.21 BTH TSP 05/94 RfD Bobbin 001 6

1.10 3RD iSP

+5.02 STH TSP 05/94 RF0 H/L Speelat Int VOL 0.36 3RD TSP

+5.14 3RD TSP 05/94 RF0 H/L Special Int VOL 0.44 3RD TSP

+5.81 3RD TSP l

05/94 RfD H/L Special Int VOL 0.48 3RD TSP

+4.54 3RD TSP 05/94 RTO H/L Special Int VOL 0.59 3RD TSP

+3.26 3RD TSP l

l 05/94 RF0 H/L Special Int VOL 0.65 3RD TSP

+1.96 3RD TSP 4 95 05/94 RF0 Bobbin NQ1 0.52 IST TSP

+25.58 8TH TSP 05/94 RF0 Bobbin NOI 0.54 IST TSP

+26.22 BTH TSP 05/94 RF0 Bobbin No!

0.59 1ST TSP

+22.32 BTH TSP 05/94 RF0 Bobbin NQI 0.63 1ST TSP

+24.26 STH TSP

]

05/94 RF0 Bobbin N01 0.79 1ST TSP

+24.94 8TH TSP l

05/94 RF0 Bobbin Not 0.95 1ST TSP

+23.62 BTH TSP 05/94 RF0 H/L Special Int VOL 0.63 2ND TSP

-8,50 2ND ISP 05/94 RF0 H/L Special Int VOL 0.73 2ND TSP

-6.01 2ND ISP 05/94 RF0 H/L Special Int VOL 0.76 2ND ISP

-2.02 2ND TSP 05/94 RF0 H/L Special Int VOL 0.76 2ND TSP

-7.24 2ND TSP 05/94 RF0 H/L Special Int VOL 0.77 2ND TSP 4.65 2ND TSP

)

05/94 RF0 H/L Special Int VOL 0.82 2ND TSP 3.40 2ND ISP 4 104 05/94 RF0 Bobbin ml 13 1.35 1ST TSP

+21.87 8TH TSP 4 109 05/94 RF0 Bobbin

'I 15 1.68 STH TSP

+18.55 BTH ISP 4 113 05/94 RF0 Bobbin

  • >l 4.36 14TH TSP

+2.60 81H TSP 05/94 RF0 C/L Special Int VOL 1.24 14TH TSP

+2.60 14TH TSP 5 2 05/94 RF0 Bobbin ODI 12 1.12 9TH TSP 3.63 F/L 5 10 05/94 RF0 Bobbin ODI 10 2.10 2ND TSP

+11.7/

F/L 05/94 RF0 Bobbin 001 8

0.59 197H ISP a3.24 F/L 5 11 05/94 RF0 Bobbin 001 23 1.47 6TH TSP

+24.48 F/L 5 34 05/94 RF0 Bobbin ADI 5.5713TH TSP

+5.26 to +10.85 F/L 05/94 RF0 C/L Special Int VOL 0.79 13TH TSP

+4.12 to +11.23 13fH TSP 5 35 05/94 RF0 Bobbin No!

0.56 4TH TSP

+12.11 F/L 05/94 RF0 Bobbin ADI 1.35 10TH TSP

+10.18 F/L 05/94 RF0 Bobbin 001 18 0.50 STH TSP

-7.63 F/L 05/94 RF0 Bobbin 001 20 0.53 7TH TSP

+10.66 F/L 05/94 RF0 Bobbin 001 11 0.77 10TH TSP

+8.88 F/L i

05/94 RF0 Bobbin 001 12 2.18 171H TSP

+ 7. 5 8 F/L l

j l

l t..

ee**************************

BWNS TUBAN II (Version 2.0) 06/17/1994 06:39:09 ese.ee............**********

Catawba Nuclear Station - Unit Two

.eeeeee..... *.............*

S/G D

  • ee............*************

05/94 RF0 Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U-Bend e***************************

Page 4 of 32 S/G D - ATTACHMENT #4 INDICATIONS OF IMPERFECTIONS ROW COL DUTAGE TEST TYPE IND %TW VOLTS LOCATION EXTENT 1 05/94 RTO H/L Special Int VOL 1.02 4TH TSP

+12.21 4TH TSP 05/94 RF0 C/L Special Int VOL 0.55 10TH TSP

+8.55 10TH TSP 5 42 05/94 RF0 Bobbin NQI 0.67 2ND TSP

+28.76 F/L 05/94 RF0 Bobbin NOI 0.87 2ND TSP

+20.02 F/L 05/94 RF0 Bobbin ADI 5.77 16TH TSP

-6.16 F/L 05/94 RF0 H/L Special Int VOL 0.55 3RD tsp 7.26 3RD TSP 05/94 RF0 H/L Special Int VOL 0.72 3RD TSP

-16.08 3RD TSP 05/94 RF0 C/L Spectat Int VOL 0.63 16TH TSP 6.58 16TH TSP 5 58 05/94 RF0 Bobbin 001 7

0.34 14TH TSP

+16.05 F/L 5 65 05/94 RF0 Bobbin ADI 3.59 13TH TSP

+39.63 F/L 05/94 RF0 C/L Speclat Int VOL 0.45 12TH TSP

-3.37 12TH TSP 5 76 05/94 RF0 Bobbin ADI 9.31 12TH TSP

+23.65 F/L 5 81 05/94 RF0 Bobbin 001 10 3.08 11TH TSP

+25.30 F/L 5 82 05/94 RF0 Bobbin ADI 4.44 16TH TSP

+6.97 F/L 05/94 RF0 C/L Special Int VOL 0.4716f H TSP

+ 6. 74 16TH TSP 05/94 RF0 C/L Special Int VOL 0.66 16TH TSP

+4.20 16TH TSP 5 84 05/94 RF0 Bobbin ADI 5.56 7TH TSP

+25.09 F/L 05/94 RF0 H/L Speclat Int VOL 0.58 7TH TSP

+24.89 7TH TSP 5 98 05/94 RF0 Bobbin ADI 5.00 12TH TSP

+37.41 F/L 5 105 05/94 RF0 Bobbin ADI 1.84 10TH TSP

+15.51 F/L 05/94 RF0 Bobbin ADI 1.97 10TH TSP

+41.55 F/L 05/94 RF0 Bobbin ADI 3.96 18TH TSP

+12.61 F/L 05/94 RF0 C/L Spectat Int VOL 0.39 10TH TSP

+14.47 10TH TSP 05/94 RF0 C/L Special Int VOL 0.98 17TH TSP

-5.57 17TH TSP 5 107 05/94 RF0 Bobbin 001 2

1.41 3RD TSP

+16.14 F/L 6

1 05/94 RF0 Bobbin NQI 0.39 10TH TSP

+23.76 F/L 05/94 RF0 C/L Special Int VOL 0.62 10TH TSP

+23.80 10TH TSP 6 2 05/94 RF0 Bobbin 001 1

1.11 BTH TSP

-4.69 F/L 6 3 05/94 RF0 sobbin ODI 14 2.47 10TH TSP

+39.01 F/L 6 5 05/94 RF0 Bobbin ADI 1.30 9TH TSP

- 7. 64 F/L 05/94 RF0 Bobbin NQI 0.41 8TH TSP

+1.18 F/L 05/94 RF0 Bobbin NQI 0.44 7TH TSP

+28.19 F/L 05/94 RF0 Bobbin No!

0.72 7TH TSP

+35.69 F/L 05/94 RF0 C/L Special Int VOL 0.44 97H TSP

-11.42 97H TSP 05/94 RF0 H/L Special Int VOL 0.40 7TH TSP

+36.16 7TH TSP 05/94 RF0 H/L Specist Int VOL 0.43 7TH TSP

+35.36 7TH TSP 05/94 RF0 H/L Special Int VOL 0.89 TTH TSP

+29.42 7TH TSP 05/94 RF0 H/L Special Int VOL 0.95 7TH TSP

+39.57 7TH TSP 6 8 05/94 RF0 Bobbin ADI 1.89 BTH TSP

~3.69 F/L 05/94 RfD Bobbin ADI 6.29 9TH TSP 1.32 F/L 05/94 RF0 C/L Special Int VOL 0.99 9TH TSP

-1.09 9TH TSP 05/94 RF0 H/L Special Int VOL 0.67 BTH TSP

-1.84 STH TSP 05/94 RF0 H/L Special Int VOL 0.90 BTH TSP

-3.59 BTH TSP 6 10 05/94 RF0 Bobbin ADI 1.05 97H TSP

+1.00 F/L 05/94 RTO C/L Special Int VOL 0.45 97H TSP

+1.24 97H TSP 6 18 05/94 RF0 Bobbin NQI 0.35 10TH TSP

+26.86 F/L 05/94 RF0 Bobbin 001 1

0.60 71H TSP

+25.40 F/L 05/94 RF0 Bobbin 001 9

1.35 7TH TSP

+22.54 F/L 05/94 RF0 Bobbin 001 21 1.00 7TH TSP

+26.90 F/L 05/94 RF0 Bobbin 001 10 0.53 10TH TSP

+24.40 F/L 05/94 RF0 Bobbin 001 13 0.97 10TH TSP

+24.63 F/L 05/94 RF0 Bobbin 001 17 0.65 10TH TSP

+22.40 F/L

~6 19 05/94 RF0 Bobbin No!

0.73 10TH TSP

+32.81 F/L 05/94 RF0 C/L Special Int VOL 0.45 9TH TSP

-14.96 9TH f**

6 27 05/94 RF0 Bobbin N01 0.36 7TH TSP

+30.91 F/L i

6 35 05/94 RF0 Bobbin 001 9

0.93 10TH TSP

+26,00 F/L 05/94 RF0 C/L Special Int VOL 0.9710TH TSP

+27.75 10TH TSP i

6 59 05/94 RF0 Bobbin NQI 0.89 2ND TSP

+33.62 F/L

)

05/94 RF0 Bobbin 001 4

0.8716TH TSP

+13.13 F/L j

05/94 RF0 H/L Special Int VOL 0.77 3RD TSP

-2.70 3RD TSP 4

6 66 05/94 RF0 Bobbin ADI 4.40 2ND TSP

+14.06 F/L 05/94 RF0 Bolrin ADI 5.15 3RD TSP

+8.40 F/L 05/94 RF0 H/L Special Int VOL 0.96 2ND TSP

+13.52 2ND TSP 05/94 RF0 H/L Special Int VOL 0.99 3RD TSP

+8.97 3RD TSP 6 68 05/94 RF0 Bobbin ADI 6.70 4TH TSP

+14.72 F/L 05/94 RF0 H/L Special Int VOL 0.B4 4TH TSP

+14.23 STH TSP J

i

BWNS TUBAN II (Version 2.0) 06/17/1994 06:39:09 Catewba Nuclear Station - Unit Two Sfg 9 05/94 RF0 Bobbin,C/L Special Interest,H/L Specist Interest,H/L Tubesheet,U-Bend Page 5 of 32 S/G 0 - ATTACHMENT #4 INDICATIONS OF IMPERFECTIONS ROW COL OUTAGE TEST TYPE IND %TW VOLTS LOCATION EXTENT 1 6 77 05/94 RF0 Bobbin ADI 4.34 18TH TSP

+9.42 F/L 05/94 RF0 C/L Special Int VOL 0.61 18TH TSP

+8.90 187H TSP 6 81 05/94 RF0 Bobbin NQI 0.57 12TH TSP

+6.11 F/L 05/94 RF0 C/L Special Int VOL 0.43 12TH TSP

+6.22 12TH TSP 6 82 05/94 RFO Bobbin 001 17 0.35 TTS-HL

+7.40 F/L 05/94 RF0 Bobbin ADI 4.13 18TH TSP

+8.73 F/L 05/94 RF0 C/L Special Int VOL 0.64 18TH TSP

+8.19 18TH TSP 05/94 RF0 C/L Spectat Int VOL 0.79 18TH TSP

+8.73 18TH TSP 05/94 RF0 H/L Special Int VOL 0.57 T1S-HL

+6.93 to

+8.43 TTS-HL 6 91 05/94 RF0 Bobbin ADI 4.42 4TH TSP

+10.60 F/L 05/94 RF0 Bobbin ADI 6.60 16TH TSP

+9.08 F/L 05/94 RF0 C/L Special Int VOL 0.90 lith TSP

+9.08 16TH TSP 6 100 05/94 RF0 Bobbin ADI 5.31 3RD TSP

+ 7. 4 7 F/L 05/94 RF0 Bobbin ODI 16 1.67 3RD TSP

+5.26 F/L 05/94 RF0 H/L Special Int VOL 0.90 3RD TSP

+5.24 3RD TSP 05/94 RF0 H/L Special Int VOL 1.07 3RD TSP

+7.62 3RD TSP 7 2 05/94 RF0 Bobbin ADI 4.0710TH TSP

+30.07 F/L 7 3 05/94 RF0 Bobbin ADI 1.92 7TH TSP

+30.60 F/L 05/94 RF0 H/L Special Int VOL 0.90 7TH TSP

+30.14 77H TSP 7 8 05/94 RFO Bobbin NQI 1.48 1STH TSP

+8.35 F/L 05/94 RF0 C/t Special Int VOL 0.71 15fH TSP

+9.16 15TH TSP l

7 11 05/94 RF0 Bobbin NQI 0.78 7TH TSP

+16.51 F/L f'

05/94 RF0 H/L Special Int YOL 0.98 7TH TSP

+16.62 7TH TSP 7 25 05/94 RF0 Bobbin ADI 6.25 7TH TSP

+33.11 F/L 7 26 05/94 RF0 Bobbin No!

1.09 14TH TSP

+10.09 F/L 05/94 RF0 C/L Special Int VOL 0.70 14TH TSP

+11.20 14TH TSP 7 36 05/94 RF0 Bobbin 001 14 3.38 4TH TSP

+8.63 F/L 7 56 05/94 RF0 Bobbin ADI 2.86 11TH TSP

+18.38 F/L 05/94 RF0 Bobbin ADI 4.31 13TH TSP

+14.11 F/L l

05/94 RF0 Bobbin ADI 4.63 11TH TSP

+25.52 F/L 05/94 RF0 C/L Special Int VOL 0.55 13TH TSP

+15.39 13TH TSP 05/94 RF0 C/L Special Int VOL 0.73 11TH TSP

+18.87 11TH TSP 05/94 RF0 C/L Special Int VOL 0.91 11TH TSP

+26.08 11TH TSP 7 58 05/94 RF0 Bobbin ADI 2.87 4TH TSP

+41.19 F/L 05/94 RF0 Bobbin NQI 0.79 4TH TSP

+33.71 F/L l

05/94 RF0 Bobbin NQ1 0.99 1ST TSP

+7.03 F/L t

05/94 RF0 H/L Special Int VOL 0.44 STH TSP

+0.79 STH TSP 05/94 RF0 H/L Specia! Int VOL 0.76 1ST TSP

+6.55 1ST TSP j

05/94 RFO H/L Special Int VOL 0.96 STH TSP

-1.51 STH TSP

{

05/94 RF0 H/L Special Int VOL 1.15 STH TSP

-9.11 STH TSP l

7 69 05/94 RF0 Bobbin ADI 2.39 2ND TSP

+5.37 F/L 05/94 RFO Bobbin NQI 0.41 17TH TSP

+10.21 F/L 7 71 05/94 RF0 Bobbin ADI 2.39 7TH TSP

+19.48 F/L 05/94 RF0 Bobbin Axl 16 1.42 7TH TSP

+21.76 to +35.30 F/L 05/94 RF0 Bobbin Axl 20 2.65 71H TSP

+9.65 to +12.02 F/L 05/94 RfD H/L Special Int VOL 0.29 7TH TSP

+31.57 7TH TSP 05/94 RF0 H/L Special Int VOL 0.43 7TH TSP

+24.15 7TH TSP 05/94 RF0 H/L Special Int VOL 0.48 7TH TSP

+19.17 71H TSP 05/94 RF0 H/L Special Int VOL 0.81 7TH TSP

+26.27 7TH TSP 05/94 RFC H/L Special Int VOL 1.40 7TH TSP

+29.48 7TH TSP 05/94 RF0 H/L Special Int VOL 0.48 7TH TSP

+21.23 tc +23.95 7TH TSP 05/94 RF0 H/L Special Int VOL 0.74 7TH TSP

+9.50 to +11.12 7TH TSP j

7 84 05/94 RF0 Bobbin ADI 3.72 10TH TSP

+11.38 F/L J

05/94 RFC Bobbin 001 7

0.62 7TH TSP

+16.11 F/L 05/94 RF0 Bobbin 001 5

1.48 10TH TSP

+17.68 F/L 05/94 RF0 C/L Special Int VOL 0.33 10TH TSP

+9.83 10TH TSP 7 98 05/94 RF0 Bobbin 001 25 0.77 2ND TSP

+13.88 F/L 7 99 05/94 RF0 Bobbin ADI 6.01 13TH TSP

+17.43 F/L i

05/94 RF0 C/L Special Int VOL 0.45 13fH TSP

+17.43 13TH TSP

)

I 7 112 05/94 RF0 Robbin ADI 5.25 11TH TSP

+32.29 F/L 05/94 RF0 C/L Special Int VOL 0.62 10TH TSP

-11.51 10TH TSP 8 5 05/94 RF0 Bobbin No!

1.68 BTH TSP

+1.18 F/L l

05/94 RF0 Bobbin Nol 2.10 7TH TSP

+37.04 F/L I

05/94 RF0 Bobbin ODI 20 1.10 7TH TSP

+36.00 F/L 05/94 RF0 Bobbin ODI 9

1.49 10TH TSP

+40.28 F/L 05/94 RF0 H/L Special Int VOL 0.41 BTH TSP

-6.69 BTH TSP 1

______J

BWNS TUBAN !! (Version 2.0) 06/17/1994 06:39:09 Catawba Nuclear Station

  • Unit Two

....... *****..e*** e.....e e..................... **...

Sfg n eeeeeeeeee**e.**************

05/94 RF0 Bobbin,C/L Special Interest,H/L Special In*erest,H/L Tubesheet,U-Bend e.............**************

Page 6 of 32 i

S/G D - ATTACHMENT #4 INDICATIONS OF IMPERFECTIONS ROW COL DUTAGE TEST TYPE IND %TW VOLTS LOCATION EXTENT 1 8 6 05/94 RF0 Bobbin 001 10 1.23 TTH TSP

+17.10 F/L 05/94 RF0 Bobbin 001 19 0.87 71H TSP

+26.89 F/L 8 7 05/94 RF0 Bobbin 001 1

1.61 7TH TSP

+31.07 F/L 05/94 RF0 Bobbin ODI 2

3.94 7TH TSP

+23.98 F/L 8 8 05/94 RF0 Bobbin No!

0.73 7TH TSP

+27.04 F/L 05/94 RF0 Bobbin 001 34 0.79 7TH TSP

+20.33 F/L 05/94 RF0 H/L Special Int VOL 1.73 7TH TSP

+29.51 7TH TSP 05/94 RF0 H/L Special int VOL 2.17 7TH TSP

+27.48 7TH TSP 8 12 05/94 RF0 Bobbin NQ1 1.27 7TH TSP

+26.37 F/L 05/94 RFO Bobbin NQ1 1.36 10TH TSP

+27.64 F/L 05/94 RF0 Bobbin 001 1

3.62 7TH TSP

+24.41 F/L 05/94 RF0 C/L Special Int VOL 0.49 9TH TSP

-16.27 9TH TSP 05/94 RF0 C/L Special Int VOL 0.66 91H TSP

-9.07 97H TSP 05/94 RF0 C/L Special Int VOL 1.03 9TH TSP 2.38 9TH TSP 05/94 RF0 H/L Special Int VOL 0.38 77H TSP

+25.67 7TH TSP 05/94 RF0 H/L Special Int VOL 0.73 7TH TSP

+21.28 77H TSP 8 19 05/94 RF0 Bobbin NQI 0.86 STH TSP

+16.50 F/L 05/94 RF0 H/L Special Int VOL 1.40 STH TSP

+16.13 STH TSP 8 28 05/94 RF0 Bobbin NQI 1.46 9TH TSP

+1.13 F/L 8 56 05/94 RF0 Bobbin ADI 6.54 2ND TSP

+22.76 F/L 05/94 RF0 H/L Special Int VOL 0.78 3RD TSP

-13.20 3RD TSP 8 59 05/94 RF0 Bobbin 001 25 0.48 10TH TSP

+26.16 F/L 8 60 05/94 RF0 Bobbin AXI 8

0.71 2ND TSP

+8.68 to +22.03 F/L 05/94 RF0 Bobbin AXI 28 1.18 6TH TSP

+38.14 to +40.42 F/L 05/94 RF0 H/L Special Int VOL 0.34 2ND TSP

+8.30 to +20.95 2ND TSP 8 68 05/94 RF0 Bobbin ADI 3.51 13TH TSP

+12.92 F/L 05/94 RTO C/L Special Int VOL 0.55 13TH TSP

+12.92 131H T$P 8 71 05/94 RF0 Bobbin ADI 3.70 18TH TSP

+2.78 F/L 05/94 RF0 Bobbin ADI 6.82 18TH TSP

+12.86 F/L 05/94 RF0 C/L Special Int VOL 0.48 18TH TSP

+2.78 171H TSP 05/94 RF0 C/L Special Int VOL 1.51 181H TSP

+12.86 17TH TSP 8 81 05/94 RF0 Bobbin ADI 2.68 10TH TSP

+7.04 F/L 05/94 RF0 C/L Special Int VOL 0.51 10TH TSP

+7.04 10TH TSP 05/94 RF0 C/L Special Int VOL 1.42 10TH TSP

+1.08 10TH TSP 8 84 05/94 RF0 Bobbin ADI 1.27 TTS-CL

+5.54 F/L i

05/94 RF0 Bobbin ADI 2.34 18TH TSP

+4.59 F/L 05/94 RF0 Bobbin ADI 2.44 18TH TSP

+16.30 F/L 05/94 RF0 Bobbin ADI 2.86 19TH TSP

+2.65 F/L 05/94 RF0 Bobbin ADI 4.45 101H TSP

+6.38 F/L 05/94 RF0 C/L Special Int VOL 0.34 18TH TSP

+15.80 177H TSP 05/94 RF0 C/L Special Int VOL 0.37 187H TSP

+2.27 17TH TSP 05/94 RF0 C/L Special Int VOL 0.52 18TH TSP

+4.59 17TH TSP 05/94 RF0 C/L Special Int VOL 0.53 181H TSP

+13.76 17TH TSP 05/94 RF0 C/L Special Int VOL 0.67 10TH TSP

+6.38 10TH TSP 05/94 RF0 C/L Spectat Int VOL 0.26 19TH TSP / TTS-CL

+0.00 19TH TSP 8 88 05/94 RF0 Bobbin ADI 7.79 1ST TSP

+26.94 F/L 05/94 RF0 H/L Special Int VOL 0.73 2ND TSP

-1.77 2ND TSP l

8 92 05/94 RF0 Bobbin Nol 2.12 9TH TSP

+1.43 F/L 05/94 RF0 Bobbin 001 9

0.92 7TH TSP

+23.91 F/L 05/94 RF0 Bobbin 001 1

2.39 10TH TSP

+28.37 F/L 05/94 RF0 Bobbin 001 2

3.91 10TH TSP

+26.28 F/L 8 93 05/94 RF0 Bobbin DDI 2

0.96 14TH TSP

-4.21 F/L 8 95 05/94 RF0 Bobbin ADI 3.03 10TH TSP

+2.78 F/L 8 96 05/94 RF0 Bobbin 001 10 1.28 10TH TSP

+31.99 F/L 8 104 05/94 RF0 Bobbin ADI 3.93 16TH TSP

+6.40 F/L 05/94 RF0 C/L Special int VOL 0.89 16TH TSP

+6.40 16TH TSP 8 105 05/94 RF0 Bobbin 001 15 2.38 11TH TSP

+4.87 F/L 8 107 05/94 RF0 Bobbin ADI 22.94 STH TSP

+31.67 F/L 05/94 RF0 U Bend VOL 2.93 BTH TSP

+32.97 9TH TSP 8 109 05/94 RF0 Bobbin ADI 6.1711TH TSP

+22.06 F/L 05/94 RF0 C/L Special Int VOL 1.13 10TH TSP

-20.94 10TH TSP 9 12 05/94 RF0 Bobbin 001 17 0.53 10TH TSP

+22.86 F/L 9 16 05/94 RF0 Bobbin No1 1.04 STH TSP

+6.71 F/L 9 20 05/94 RF0 Bobbin No!

0.31 STH TSP

+37.75 F/L 9 56 05/94 RF0 Bobbin 001 8

1.15 13TH TSP

+18.43 F/L 9 62 05/94 RF0 Bobbin ADI 1.67 10TH TSP

+8.44 F/L

eeeeeeeee**eeeee************

BVNS TUBAN II (Version 2.0) 06/17/1994 06:39:09 Catawba Nuclear Station - Unit Two e..........................

Sfg n 05/94 RF0 Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U-Bend Page 7 of 32 S/G 0 - ATTACHMENT #4 INDICATIONS OF IMPERFECTIONS ROW COL DUTAGE TEST TYPE IND %TW VOLTS LOCATION EXTENT 1 05/94 RF0 Bobbin Axl 22 0.53 1ST TSP

+21.52 to +24.99 F/L 05/94 RF0 H/L Special Int VOL 0.49 2ND TSP 4.98 2ND TSP 05/94 RF0 H/L Specist Int VOL 0.67 2ND TSP

-6.12 2ND TSP 05/94 RF0 H/L Special Int VOL 0.80 2ND TSP

-7.34 2ND TSP 05/94 RF0 C/L Special Int VOL 0.55 10TH TSP

+B.44 10TH TSP 9 68 05/94 RF0 Bobbin 001 6

1.78 6TH TSP

+22.61 F/L 9 71 05/94 RF0 Bobbin 001 8

1.89 2ND TSP

+32.44 F/L 9 72 05/94 RF0 Bobbin ADI 0.76 12TH TSP

+19.58 F/L 05/94 RF0 Bobbin ADI 1.03 14TH TSP

+10,85 F/L 05/94 RF0 Bobbin ADI 1.14 16TH TSP

+12.11 F/L 05/94 RF0 Bobbin ADI 1.25 13TH TSP

+4.54 F/L 9 75 05/94 RF0 Bobbin 001 2

3.13 1ST TSP

+14.84 F/L 05/94 RTO Bobbin DDI 11 1.94 2ND TSP

+11.70 F/L 9 91 03/94 RF0 Bobbin ADI 7.09 13TH TSP

+27.60 F/L 05/94 RF0 C/L Special Int VOL 0.46 12TH TSP 15.40 12TH TSP 9 92 05/94 RF0 Bobnin 001 11 1.24 17TH TSP

+7.39 F/L 9 93 05/94 RF0 Bobbin 001 14 1.70 7TH TSP

+28.64 F/L 05/94 RF0 Bobbin 001 2

1.34 15TH TSP

+8.30 F/L i

9 98 05/94 RF0 Bobbin No1 0.61 17TH TSP

+1.84 F/L i

05/94 RF0 C/l Special Int VOL 0.61 17TH TSP

+1.90 177H TSP 9 99 05/94 RF0 Bobbin 001 5

1.50 10TH TSP

+28.43 F/L 05/94 RF0 Bobbin DDI 19 0.84 10TH TSP

+19.34 F/L 9 101 05/94 RF0 Bobbin ODI 9

0.74 STH TSP

+23.52 F/L 9 103 05/94 RF0 Bobbin 001 11 3.31 2ND TSP

+9.28 F/L

?

10 3 05/94 RF0 Bobbin 001 4

0.77 7TH TSP

+27.95 F/L 05/94 RF0 Bobbin 001 22 0.58 7TH TSP

+21.19 F/L 05/94 RF0 Bobbin 001 14 0.71 10TH TSP

+37.73 F/L 10 26 05/94 RF0 Bobbin ODI 18 0.62 71H TSP

+24.55 F/L 10 31 05/94 RF0 Bobbin 001 2

0.78 TTH TSP

+35.26 F/L 05/94 RF0 Bobbin 00!

2 0.54 10TH TSP

+34.44 F/L 05/94 RF0 Bobb!n ODI 7 0.5710TH TSP

+37.30 F/L 05/94 RF0 Bobbin 001 14 0.46 10T4 TSP

+14.83 F/L 10 38 05/94 RF0 Bobbin N01 0.63 TTH TSP

+19.55 F/L 10 51 05/94 RF0 Bobbin No!

0.40 10TH TSP

+32.32 F/L 10 64 05/94 RF0 Bobbin 001 25 1.69 1ST TSP

+9.83 F/L 10 69 05/94 RF0 Bobbin ADI 3.05 11TH TSP

+5.84 F/L 05/94 RFC C/L Special Int VOL 0.35 lith TSP

+6.05 11TH TSP 10 70 05/94 RF0 Bobbin WQI 3.86 3RD TSP

+23.26 F/L 05/94 RF0 H/L Special Int VOL 0.44 3RD TSP

+22.94 3RD TSP 10 75 05/94 RF0 Bobbin DDI 13 0.70 3RD TSP

+10.00 F/L 05/94 RF0 H/L Special Int VOL 0.22 3RD TSP

+10.91 3RD TSP 10 76 05/94 RF0 Bobbin No!

0.56 12TH TSP 1.37 F/L 05/94 RF0 C/L Special Int VOL 1.34 12TH TSP

-1.37 12TH TSP 10 77 05/94 RF0 Bobbin NQI 0.18 16TH TSP

+0.04 F/L 10 88 05/94 RTO Bobbin 001 14 1.00 3RD TSP

+25.04 F/L 10 91 05/94 RF0 Bobbin 001 3

1.86 6TH TSP

+33.81 F/L 10 92 05/94 RF0 Bobbin No!

0.50 13TH TSP

+35.51 F/L 10 93 05/94 RF0 Bobbin 001 23 0.65 7TH TSP

+36.78 F/L 10 94 05/94 RF0 Bobbin ODI 15 0.56 2ND TSP

+21.06 F/L 10 96 05/94 RF0 Bobbin 001 3

1.22 10TH TSP

+3.00 F/L 05/94 RF0 C/L Special Int VOL 0.66 10TH TSP

+3.00 10TH TSP 10 106 05/94 RF0 Bobbin 001 15 0.44 2ND TSP

+3.41 F/L 05/94 RF0 Bobbin 001 2

3.48 14TH TSP

+13.71 F/L 10 109 05/94 RF0 Bobbin 001 2

0.45 10TH TSP

+23.02 F/L 10 112 05/94 RF0 Bobbin 001 6

1.22 10TH TSP

+29.30 F/L 05/94 RF0 Bobbin 001 12 0.62 15fH TSP

+14.42 F/L 10 113 05/94 RF0 Bobbin 001 9

1.18 13TH TSP

+21.74 F/L 11 2 05/94 RF0 Bobbin NQI 1.44 7TH TSP

+40.26 F/L 05/94 RF0 Bobbin ODI 14 0.80 10TH TSP

+38.82 F/L 05/94 RF0 H/L Special Int VOL 0.93 8TH TSP

-2.84 BTH TSP 11 3 05/94 RF0 Bobbin ADI 4.40 10TH TSP

+32.87 F/L 05/94 RF0 C/L Special Int VOL 0.55 9TH TSP 4.50 97H TSP 05/94 RF0 C/L Special Int YOL 0.74 97H TSP

-10.48 9TH TSP 11 4 05/94 RF0 Bobbin 001 8

0.59 7TH TSP

+29.86 F/L 11 10 05/94 RF0 Bobbin Wo!

1.10 10TH TSP

+34.89 F/L 05/94 RF0 t/L Special Int VOL 0.47 97H TSP

-7.31 9TH TSP

1

]

)

eeseeou sseeeeeeee uees*****

BWNS TUBAN !! (version 2.0) 06/17/1994 06:39:09 eeeeeeeeeeeeeueee**********

Catawba Nuclear Station Unit Two i

euneuueuunessuneese eseouseneusseeenesenses syg n enesununununeueue noseuueousueessuusuo n$79s pgn Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U Bend Page 8 of 32 S/G 0 ATTACHMENT #4 INDICAfl0NS OF IMPERFECTIONS ROW COL OUTAGE 1[ST TYPE IND %TW VOLTS LOCATION EXTEN11 05/94 RF0 C/L Special Int VOL 0.81 9TH ISP 11.31 97H TSP 11 40 05/94 RF0 Bobbin Not 0.54 10TH TSP

+39.37 F/L 11 45 05/94 RF0 Bobbin ODI 11 1.18 2ND T$P

+33.05 F/L 11 49 05/94 RF0 Bobbin No!

1.28 11TH TSP

+39.63 F/L 11 61 05/94 RF0 Bobbin ODI 8

2.02 2ND TSP

+5.53 F/L 11 73 05/94 RF0 Bobbin ODI i

1.58 121H TSP

+5.33 F/L 05/94 RF0 Bobbin ODI 10 0.88 iSTH TSP

+15.23 F/L 11 82 05/94 RF0 Bobbin ODI 12 2.12 41H TSP

+37.37 F/L 05/94 RF0 Bobbin 001 5

1.84 13fH TSP

+26.85 F/L 05/94 RF0 Bobbin ODI 29 1.88 10TH TSP

+15.77 F/L 05/94 RFC H/L Speclat Int VOL 0.35 51H ISP 5.02 STH TSP 05/94 RF0 C/L Special Int VOL 0.34 131H TSP

+26.98 13TH TSP 05/94 RF0 C/L Special Int VOL 1.16 10iH TSP

+15.77 10TH TSP 11 83 05/94 RF0 Bobbin Nol 0.28 12iH TSP

+15.76 F/L 11 88 05/94 RF0 Bobbin ODI 11 1.00 3RD TSP

+1.98 F/L 05/94 RF0 H/L Special int VOL 0.85 3RD TSP

+1.93 4TH TSP 11 89 05/94 RF0 Bobbin ADI 5.71 15TH ISP

+2.16 F/L 05/94 RF0 C/L Special Int VOL 0.57 15fH TSP

+2.16 15fH ISP 11 90 05/94 RF0 Bobbin ADI 1.89 14TH TSP

+3.74 F/L 05/94 RF0 Bobbin ADI 2.56 14TH ISP

+15.57 F/L 05/94 RF0 Bobbin 001 9

0.88 13fH TSP

+8.06 F/L 05/94 RF0 C/L Special Int VOL 0.36 14TH ISP

+12.45 14TH TSP 05/94 RF0 C/L Spectat Int VOL 0.37141H TSP

+8.57 14TH TSP 05/94 RF0 C/L Special Int VOL 0.39 14TH TSP

+16.71 14TH TSP 05/94 RF0 C/L Speclat Int VOL 0.41 14TH TSP

+7.22 14TH TSP 05/94 RF0 C/L Speclat Int VOL 0.44 14fH ISP

+14.91 14TH TSP 05/94 RIO C/L Spectat Int VOL 0.55 141H TSP

+3.54 14TN TSP 11 92 05/94 RF0 Bobbin ADI 2.33 141H TSP

-2.42 F/L 05/94 RF0 C/L Special Int VOL 0.38 14TH ISP 2.43 14TH TSP 11 93 05/94 RF0 Bobbin ADI 2.12 14TH TSP

-2.22 F/L 05/94 RF0 Bobbin ADI 3.92 127H TSP

+9.83 F/L 05/94 RF0 C/L Special Int VOL 0.31 121H TSP

+9.83 12TH ISP 05/94 RF0 C/L Special Int VOL 0.40 14TH TSP

-2,22 14TH ISP 11 95 05/94 RF0 Bobbin ADI 3.21 1?TH ISP

+14.33 F/L 05/94 RF0 C/L Special Int VOL 0.33 12TH TSP

+14.51 12TH TSP 12 3 05/94 RF0 Bobbin No!

0.57 10TH ISP

+30.46 F/L 12 13 05/94 RF0 Bobbin 001 12 2.41 12TH ISP 1.67 F/L 05/94 RF0 C/L Spectat Int VOL 1.26 12TH TSP 1.59 121H TSP 12 80 05/94 RIO Bobbin 001 6

1.81 7TH TSP

+31.16 F/L 05/94 RF0 Bobbin 001 13 1.36 15TH TSP

+8.62 F/L 12 91 05/94 RF0 Bobbin No!

0.55 2ND TSP

+10.09 F/L 05/94 RF0 H/L Special Int VOL 0.86 2ND TSP

+10.58 2ND TSP 12 109 05/94 RF0 Bobbin 001 21 1.28 71H TSP

+29.05 F/L 05/94 RF0 Bobbin 001 21 1.89 6fH TSP

+39.40 F/L 05/94 RF0 Bobbin 001 24 1.17 TTH TSP

+18.84 F/L 05/94 RF0 H/L Special Int VOL 1.13 71H TSP

+19.02 7TH TSP 05/94 RF0 H/L Special Int VOL 1.14 7tM TSP

+29.48 7TH TSP 05/94 RF0 H/L Spectat Int VOL 1.36 71H TSP

+21.84 7TH TSP 05/94 RF0 H/L Spectat Int VOL 1.54 71H TSP

-3.78 7TH TSP 13 7 05/94 RF0 Bobbin 001 30 0.70 71H ISP

+36.52 F/L 13 10 05/94 RF0 Bobbin 001 8

1.30 12TH TSP

+25.49 F/L 13 41 05/94 RF0 Bobbin ODI 9

0.67 16TH TSP

+15.07 F/L 13 69 05/94 RF0 Bobbin 001 3

0.94 13fH TSP

+2.44 F/L 05/94 RF0 Bobbin 001 8

1.68 13TH ISP

+24.17 F/L 05/94 RF0 Bobbin 001 13 0.8713f H TSP 18.07 F/L 13 83 05/94 RF0 Bobbin 001 3

0.84 13fH TSP

-1.24 F/L i

13 85 05/94 RF0 Bobbin ADI 2.46 111H TSP

+18.85 F/L 05/94 RF0 Bobbin 001 7

1.68 171H ISP

+10.B4 F/L 05/94 RF0 Bobbin 001 31 0.97 12rH TSP

+16.36 F/L 05/94 RF0 C/L Speclat Int VOL 0.68 12iH ISP

+15.64 12tH TSP 05/94 RF0 C/L Special Int VOL 0.71 16fH TSP

-6.44 16fH TSP 05/94 RF0 C/L Speclot Int VOL 0.78 11TH ISP

+18.85 111H ISP 13 86 05/94 RF0 Bobbin ODI 1

1.98 161H TSP

-5.30 F/L 13 88 05/94 RF0 Bobbin 001 33 1.03 151H TSP

-6.41 F/L 05/94 RF0 C/L Special Int VOL 0.95 15fH ISP 6.08 151H TSP 13 90 05/94 RF0 Bobbin ADI 4.58 131H ISP

+7.74 F/L i

I BWNS TUBAN 11 (Version 2.0) 06/17/1994 06:39:09 Catawba Nuclear Station

  • Unit Two ee..........................

$fg n 05/94 RF0 Bobbin,C/L Special Interest,H/L Spectat Interest,H/L Tubesheet,U Bend Page 9 of 32 S/G D ATTACHMENT #4 INDICATIONS OF IMPERFECTIONS RDW COL OUTAGE TEST TYPE IND %fW VOLTS LOCATION EXTENT 1 05/94 RFO Hobbin 001 12 2.85 7TH TSP

+ 17. 58 F/L 05/94 RF0 C/L Special Int VOL 0.61 13TH TSP

+7.76 13TH TSP 13 92 05/94 RF0 Bobbin 001 7

4.03 13TH TSP

+28.15 F/L 05/94 RF0 Bobbin 001 8

3.29 12TH TSP

+23.98 F/L 05/94 RF0 Bobbin 001 10 4.26 13TH TSP

+3.48 F/L 05/94 RF0 Bobbin 001 15 2.5712TH TSP

+12.02 F/L 05/94 RF0 Bobbin ODI 16 2.47 13TH TSP

+38.55 F/L 05/94 RF0 Bobbin 001 19 2.51 13TH TSP

+26.90 F/L 13 103 05/94 RF0 Bobbin 001 12 1.63 STH TSP

+16.88 F/L 05/94 RF0 H/L Special Int VOL 1.40 STH TSP

+17.20 STH TSP 13 109 05/94 RF0 Bobbin 001 9

1.01 17TH TSP

+6.90 F/L 05/94 RF0 C/L Speclat Int VOL 0.44 16TH TSP 11.10 16TH TSP 14 6 05/94 RF0 Bobbin 001 6

1.60 4TH TSP

+40.17 F/L 14 39 05/94 RF0 Bobbin No!

0.90 BTH TSP

-2.02 F/L 14 63 05/94 RF0 Bobbin 001 2

1.09 13TH TSP

+4.85 F/L 14 65 05/94 RF0 Bobbin ADI 2.48 15TH TSP

+10.78 F/L 05/94 RF0 Bobbin ODI 7

0.93 7TH TSP

+17.45 F/L 05/94 RF0 C/L Special Int VOL 0.37 14TH ISP 8.11 14TH TSP 14 69 05/94 RF0 Bobbin ADI 2.39 15TH TSP

+6.33 F/L 05/94 RF0 t/L Special Int VOL 0.49 15TH TSP

+5.83 15TH TSP 14 73 05/94 RF0 Bobbin ODI 6

1.20 6TH TSP

+36.13 F/L 14 77 05/94 RF0 Bobbin DDI 13 1.94 4TH TSP

+34.71 F/L 14 82 05/94 RF0 Bobbin ADI 6.18 1AVB

+4.97 F/L 05/94 RF0 Bobbin 001 4

1.90 4TH TSP

+40.62 F/L 05/94 RF0 U Bend VOL 0.57 1 AVB

+5.78 9TH TSP 05/94 RF0 H/L Special Int VOL 0.47 STH TSP

-1.91 STH TSP 14 86 05/94 RF0 Bobbin 001 2

1.82 2ND TSP

+30.57 F/L 14 87 05/94 Rio Bobbin 001 2

1.63 13TH TSP

+23.69 F/L 14 91 05/94 RF0 Bobbin 001 13 2.90 9TH TSP 4.47 F/L 14 103 05/94 RF0 Sobbin NQ1 0.47 4TH TSP

+31.09 F/L 05/94 RF0 Bobbin NQ1 0.66 7TH TSP

+3.94 F/L 05/94 RFC H/L Spectat Int VOL 0.69 7TN TSP

+4.11 7TH TSP 05/94 RF0 H/L Special Int VOL 0.88 STH TSP 11.90 STH TSP 14 104 05/94 RIO Bobbin 001 5

3.87 TTS-HL

+1.74 F/L 05/94 RF0 H/L Special Int VOL 1.00 TTS-ML

+1.81 1ST TSP 15 5 05/94 RF0 Bobbin 001 3

1.71 10TH TSP

+24.18 F/L 05/94 RF0 Bobbin 001 39 0.48 1CTH TSP

+23.56 F/L 15 6 05/94 RF0 Bobbin No!

0.48 10TH TSP

+22.22 F/L 15 8 05/94 RF0 Bobbin 001 3

0.76 10TH TSP

+28.20 F/L 15 49 05/94 RF0 Bobbin WAR 27 1.82 1AVB

+0.00 F/L 15 58 05/94 RF0 Bobbin 001 6

1.00 12TH TSP

+19.76 F/L 15 62 05/94 RF0 Bobbin ODI 4

1.64 7TH TSP

+28.42 F/L 05/94 RF0 Bobbin 001 15 0.41 7TH TSP

+36.11 F/L 05/94 RF0 Bobbin 001 7

1.51 10TH TSP

+37.02 F/L 05/94 RF0 Bobbin 001 19 0.57 10TH TSP

+36.49 F/L 15 72 05/94 RF0 Bobbin 001 2

0.58 6TH TSP

+22.72 F/L 05/94 RF0 Bobbin 001 4

0.63 12TH TSP

+9.49 F/L 15 77 05/94 RF0 Bobbin ADI 5.39 14TH TSP

+6.17 F/L 05/94 RF0 C/L Special int VOL 1.05 14TH TSP

+6.06 14TH TSP 15 79 C3/94 RF0 Bobbin 001 11 1.76 181H TSP

+10.98 F/L l

05/94 RF0 Bobbin 001 20 1.52 12TH TSP

+41.26 F/L l

15 82 05/94 RF0 Bobbin ADI 3.31 11TH TSP

+24.39 F/L 05/94 RF0 C/L Special Int VOL 0.24 11TH TSP

+26.33 11TH TSP 15 87 05/94 RF0 Bobbin 001 25 0.72 3RD TSP

+25.41 F/L 15 90 05/94 RF0 Bobbin 001 9

1.32 14TH TSP

+4.80 F/L 15 91 05/94 RF0 Bobbin 001 11 0.93 3RD TSP

+26.08 F/L 05/94 RF0 H/L Specist Int VOL 0.96 3RD TSP

+26.24 3RD TSP 15 98 05/94 RF0 Bobbin ADI 2.68 10TH TSP

+12.19 F/L 05/94 RF0 Bobbin 001 14 1.93 16TH TSP

-8.29 F/L 05/94 RF0 C/L Special Int VOL 0.48 10TH TSP

+11.37 10TH TSP 15 101 05/94 RF0 Bobbin 001 17 0.61 1ST TSP

+11.60 F/L 05/94 RF0 Bobbin ODI 19 0.85 1ST TSP

+11.60 F/L 15 104 05/94 RTO Bobbin DDI 19 1.24 10TH TSP

+32.89 F/L 05/94 RF0 Bobbin 001 22 1.2710TH TSP

+29.61 F/L 15 108 05/94 RF0 H/L Tubesheet NQI 3.07 TTS HL

+0.00 TTS-HL j

16 4 05/94 RF0 Bobbin NQ1 0.40 STH TSP

+20.82 F/L i

l i

e.......... **............

BWNS TUBAN !! (Version 2.0) 06/17/1994 06:39:09 Catawba Nuclear Station Unit Two e**ee***********************

S/G D 1

e eeeee*********************

05/94 RTO e...............***********

Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U-Bend I

Page 10 of 32 S/G 0 - ATTACHMENT #4 INDICATIONS OF IMPERFECTIONS ROW COL DUTACE TEST TYPE IND %TW VOLTS LOCATION EXTENT 1

~

05/94 RF0 H/L Special Int VOL 1.12 STH TSP

  • 20.58 STH TSP 16 12 05/94 RF0 Bobbin 001 3

0.60 10TH TSP

+35.26 F/L 16 13 05/94 RF0 Bobbin 001 8

1.80 1ST TSP

+14.76 F/L 16 19 05/94 RF0 Bobbin 001 4

0.50 10TH TSP

+40.41 F/L 16 20 05/94 RF0 Bobbin No!

0.53 STH TSP

+27.30 F/L 05/94 RF0 H/L Special Int VOL 0.82 STH TSP

+26.15 STH TSP 16 23 05/94 RF0 Bobbin 001 22 0.27 7TH TSP

+23.19 F/L 16 24 05/94 RF0 Bobbin 001 11 0.44 10TH TSP

+22.41 F/L i

16 53 05/94 RF0 Bobbin No!

0.70 STH TSP

+19.67 F/L 05/94 RF0 Bobbin 001 1

1.30 6TH TSP

+13.39 F/L

.~

05/94 RF0 Bobbin 001 19 1.05 4TH TSP

-1.91 F/L 05/94 RFO Bobbin 001 34 1.06 7TH TSP

+25.97 F/L 1

05/94 RF0 Bobbin 001 1

3.3714TH TSP

+9.52 F/L 05/94 RF0 Bobbin 001 20 0.74 10TH TSP

+20.87 F/L 16 62 05/94 RF0 Bobbin ADI 3.99 7TH TSP

+40.66 F/L 05/94 RF0 Bobbin 001 8

1.57 7TH TSP

+39.50 F/L 1

05/94 RF0 Bobbin DDI 16 2.12 10TH TSP

+40.70 F/L 05/94 RF0 H/L Special Int VOL 0.71 BTH TSP

-1.07 81H TSP 05/94 RF0 H/L Special Int VOL 1.09 8fH TSP

-4.04 8TH TSP 05/94 RF0 H/L Special Int VOL 2.40 BTH TSP

-2.91 BTH TSP 16 63 05/94,*FO Bobbin ADI 3.06 11TH TSP

+4.25 F/L 05/94 RF0 C/L Special Int VOL 0.58 11TH TSP

+4.29 11TH TSP 16 72 05/94 RF0 Bobbin NQ1 0.46 11TH TSP

+37.27 F/L 05/94 RF0 C/L Special Int VOL 0.49 10TH TSP

-5. 64 10TH TSP 16 84 05/94 RF0 Bobbin ADI 4.73 15TH TSP

+11.65 F/L 05/94 RF0 C/L Special Int VOL 0.44 14TH TSP

-8.09 14TH TSP 16 87 05/94 RF0 Bobbin ADI 7.65 12TH TSP

+27.79 F/L 4

05/94 RF0 C/L Special Int VOL 0.67 11TH TSP

-15.21 11TH 6*P 16 88 05/94 RF0 Bobbin ADI 17.72 11TH TSP

+15.51 F/L 05/94 RF0 C/L Snecial Int VOL 1.98 11TH TSP

+15.51 11TH TSP

{

16 93 05/94 EF0 Bobbin No!

0.45 4AVB

-15.55 F/L 05/94 RF0 U-Bend VOL 0.75 4AVB

-15.71 9TH TSP 05/94 RF0 Bobbin 001 5

0.59 157H TSP

+10.56 F/L e

16 99 05/94 RF0 Bobbin ADI 6.38 13Tn TSP

+39.08 F/L 05/94 RF0 C/L Special Int VOL 0.33 12TH TSP

-5.86 12TH TSP i

i 05/94 RF0 C/L Special Int VOL 0.68 12TH TSP

-3.92 12TH TSP 16 100 05/94 RF0 Bobbin ADI 7.5011TH TSP

+34.34 F/L 05/94 RF0 C/L Special Int VOL 0.49 10TH TSP

-8.66 10TH TSP 16 101 05/94 RF0 Bobbin ADI 3.27 11TH TSP

+14.15 F/L 05/94 RF0 C/L Special Int VOL 0.29 11TH TSP

+12.43 11TH TSP 16 110 05/94 RF0 Bobbin 001 9

2.19 6TH TSP

+33.33 F/L 17 5 05/94 RF0 Bobbin No!

0.40 10TH TSP

+30.40 F/L 05/94 RFO C/L Special Int VOL 1.19 9TH TSP 13.33 9TH TSP 17 8 05/94 RF0 Bobbin ADI 2.27 STH TSP

+13.74 F/L 05/94 RF0 Bobbin ADI 4.08 11TH TSP

+24.77 F/L 05/94 RF0 H/L Special Int VOL 1.04 STH TSP

+13.93 STH TSP 05/94 RF0 C/L Special Int VOL 0.52 11TH TSP

+24.15 10TH TSP 17 23 05/94 RF0 Bobbin N01 0.61 14TH TSP

+0.11 F/L 05/94 RF0 C/L Special Int VOL 0.29 14TH TSP

+0.11 14TH TSP 17 25 05/94 RF0 Bobbin 001 6

1.56 16TH TSP

+10.30 F/L 17 36 05/94 RF0 Bobbin No!

0.75 6TH TSP

+13.05 F/L 05/94 RF0 H/L Special Int VOL 0.81 6TH TSP

+12.95 6TH TSP 17 40 05/94 RF0 Bobbin NQI 1.36 10TH TSP

+10.63 F/L 05/94 RF0 C/L Special Int VOL 1.11 10TH TSP

+10.63 10TH TSP 17 42 C5/94 RF0 Bobbin 001 3

1.87 6TH TSP

+8.50 F/L 17 47 05/94 RF0 Bobbin No!

0.58 1ST TSP

+9.78 F/L 05/94 RF0 H/L Special Int VOL 0.31 1ST TSP

+15.98 1ST TSP 05/94 RF0 H/L Special Int VOL 0.43 1ST TSP

+14.26 1ST TSP 05/94 RF0 H/L Special Int VOL 0.66 1ST TSP

+18.13 1ST TSP 05/94 RF0 H/L Special Int VOL 0.98 1ST TSP

+8.99 1ST TSP 1

17 50 05/94 RF0 Bobbin 001 5

0.74 2ND TSP

+ 29. 64 F/L 17 59 05/94 RF0 Bobbin ODI 11 3.21 2ND TSP

+30.08 F/L 05/94 RF0 Bobbin 001 11 5.13 2ND TSP

+26.81 F/L 95/94 RF0 Bobbin 001 25 1.34 2ND TSP

+10.40 F/L 05/94 RFC Bobbin ODI 26 1.72 2ND TSP

+25.12 F/L 05/94 RF0 Bobbin 001 35 1.27 2ND TSP

+23.97 F/L

~

-\\

'l

..*.e eeeee.e***************

BWNS TUBAN !! (version 2.0) 06/17/1994 06:39:09

                  • eu...............

eteneee*eseeeeeees.es**ee***

Catawba Nuclear Station - Unit Two

      • eee*e..................**

S/G D eeeeeeee........e...........

05/94 RF0

..**e............***********

Bobbin,C/L Special Interest,H/L $peclat Interest,H/L Tubesheet,U Bend Page 11 of 32 S/G D ATTACHMFNI #4 !NDICATIONS OF IMPERIEC110NS ROW COL OUTAGE ILST TYPE IND XTW VOLi$ LOCATION EXTENT 1 05/94 RF0 H/L Special Int VOL 0.83 2ND TSP

+24.11 2ND TSP 05/94 RF0 H/L Special Int VOL 0.98 2ND TSP

+25.47 2ND TSP 05/94 RF0 H/L Special Int VOL 0.43 2ND TSP

+8.69 to +11.88 2ND TSP 05/94 RF0 H/L Special Int VOL 0.60 2ND TSP

+3.55 to

+6.59 2ND TSP j

17 65 05/94 RF0 Bobbin ADI 8.06 12iH ISP

+9.76 F/L 05/94 RF0 C/L Special Int VOL 0.74 12TH TSP

+9.51 12FH TSP 17 87 05/94 RF0 Bobbin ODI 16 4.19 3RD TSP

+32.40 F/L 05/94 RF0 Bobbin ODI 19 5.14 3RD TSP

+34.69 F/L 05/94 RF0 Bobbin 001 9

2.18 13fH TSP

+40.78 F/L 05/94 RF0 pobbin ADI 5.68 3RD TSP

+15.76 to +21.86 F/L 05/94 RF0 Bobbin ADI 6.35 4TH TSP

+2.09 to +21.27 F/L 05/94 RF0 Bobbin ADI 10.28 2ND TSP

+20.99 to +28.03 F/L 05/94 RF0 H/L Speclot Int VOL 0.41 2ND TSP

+21.39 2ND TSP 05/94 RF0 H/L Special Int VOL 0.44 2ND TSP

+22.71 2ND TSP 05/94 RF0 H/L Special Int VOL 0.66 4TH TSP

+2.62 4TH TSP 05/94 RF0 H/L Speelal Int VOL 0.75 2ND TSP

+25.16 2ND ISP 05/94 RF0 N/L Special Int VOL 0.89 4TH TSP

+5.43 4TH TSP 05/94 RF0 H/L Special Int VOL 1.15 4TH TSP

+ 7. 86 4TH TSP 05/94 RF0 H/L Special Int VOL 1.19 2ND TSP

+26.85 2ND iSP 05/94 RF0 H/L Specist Int VOL 1.63 3RD TSP

+21.16 3RD TSP 05/94 RF0 H/L Special Int VOL 1.69 4Th TSP 0.82 4TH TSP 05/94 RF0 H/L Special Int VOL 1.74 3RD iSP

+19.62 3RD TSP 05/94 RF0 H/L Special Int VOL 2.28 3RD TSP

+16.29 3RD TSP 17 90 05/94 RF0 Bobbin ADI 4.85 13fH TSP

+31.34 F/L 05/94 RF0 C/L Spectat Int VOL 0.43 12iH ISP

-12.66 12TH ISP 17 93 05/94 RF0 Bobbin 001 16 0.82 161H ISP

+11.47 F/L 17 106 05/94 RF0 Bobbin ADI 3.07 71H ISP

+12.99 F/L 05/94 RF0 H/L Special Int VOL 0.72 71H TSP

+13.33 71H TSP 17 108 05/94 RF0 Bobbin ADI 3.72 111N TSP

+10.37 F/L 05/94 RF0 C/L Special Int YOL 0.22 1'TH TSP

+10.37 111H TSP 18 9 05/94 RF0 Bobbin ODI 5

1.33 1(TH TSP

+39.75 F/L 18 20 05/94 RF0 Bobbin ADI 7.25 16TH ISP

+1.81 F/L 05/94 RF0 C/L Speclat Int VOL 1.d 16TH ISP

+1.81 16TH TSP 18 59 05/94 RF0 Bobbin 001 11 1.39 IST TSP

+15.67 F/L i

18 72 05/94 RF0 Bobbin ADI 4.54 18TH TSP

+14.10 F/L 05/94 RF0 C/L Special Int VOL 0.42 17TH TSP 4.26 177H TSP 18 73 05/94 RF0 Bobbin ADI 3.43 131H TSP

+1.72 to + 17. 96 F/L 05/94 RF0 C/L Speclat Int VOL 0.20 131H TSP

+6.08 to

+9.20 13fH ISP 18 80 05/94 RF0 Bobbin 001 3

3.25 13TH ISP

+23.06 F/L 05/94 RF0 Bobbin 001 4

3.17 13TH TSF-

+31.56 F/L 05/94 RF0 Bobbin 001 4

6.58 11FH TSP

+21.41 F/L 05/94 RF0 Bobbin 001 8

4.50 131H ISP

+27.83 F/L 05/94 RF0 Botbin ODI 11 8.08 131H TSP

+33.48 F/L 18 85 05/94 RF0 Bothin ADI 4.40 187H TSP

+15.34 F/L l

05/94 RF0 C/L Special Int VOL 0.58 17TH TSP

-3.18 171H TSP 18 86 05/94 RF0 Bottin ADI 2.15 6TH TSP

+35.00 F/L 05/94 RF0 H/L Speclat Int VOL 0.71 71H ISP

-5.89 71H TSP 05/94 RF0 H/L Special Int VOL 0.82 77H TSP

-5.06 7TH TSP 18 87 05/94 RF0 Bobbin ADI 7.30 191 TSP

+13.69 F/L l

05/94 RF0 H/L Special Int VOL 1.04 1ST TSP

+13.49 1ST TSP 18 96 05/94 RF0 Bobbin ADI 3.01 10TH FSP

+41.19 F/L t

05/94 RF0 C/L Specist Int VOL 0.55 97H TSP

-4.67 91H ISP 18 108 05/94 RF0 Bobbin ADI 2.17 4TH TSP

+ 7.96 F/L 05/94 RF0 Bobbin ADI 3.52 3RD TSP

+31.22 F/L 05/94 RF0 H/L Special Int VOL 0.60 4TH ISP 4.52 4TH TSP 05/94 RF0 H/L Speclat ' Int VOL 1.14 41H TSP

+8.46 41H TSP 05/94 RFC H/L Special Int Vol 1.46 4TH TSP

+4.73 4TH TSP 18 110 05/94 RF0 Bobbin ADI 2.30 131H TSP

  • 14.19 F/L 05/94 RF0 C/L Specist Int VOL 0.67 13TH TSP

+11.29 to +20.16 131H TSP 19 13 05/94 RF0 Fabbin 001 6

0.92 10TH TSP

+37.34 F/L 19 22 05/94 RF0 Bobbin ODI 21 0.85 10iH TSP

+42.59 F/L 19 23 05/94 RF0 Bobbin NOl 1.93 71H TSP

+27.66 F/L 0$/94 RF0 Bobbin hol 1.17 111H ISP

+33.54 F/L 05/94 RF0 Bobbin 001 31 1.34 TTH TSP

+8.79 F/L r

05/94 RF0 Bobbin ODI 6

1.00 10TH ISP

+9.84 F/L 05/94 RF0 H/L Special Int VOL 0.44 7tH TSP

i

.........e******************

BWNS TUBAN 11 (Version 2.0) 06/17/1994 06:39209 eeeeeeeeee.eeeeeeeeeeeeeee**

Catawba Nuclear Station Unit Two ee..........................

Sfg n eseee.ee*.e*****************

05/94 RF0 Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U-Bend eeeeeeee....... u n...******

Page 12 of 32 S/G D ATTACHMENT #4 !NDICAi!ONS OF !MPERFECTIONS ROW COL OUTAGE TEST TYPE IND %TW VOLTS LOCATION EXTENT 1 05/94 RF0 C/L Special Int VOL 0.30 11TH TSP

+33.82 11TH TSP 19 60 05/94 RF0 Bobbin 001 25 0.78 187H TSP

+6.04 F/L 05/94 RF0 C/L Special Int VOL 0.98 187H TSP

+5.89 18TH TSP 19 61 05/94 RF0 Bobbin NQI 0.34 111H TSP

+34.94 F/L 05/94 RF0 C/L Special Int VOL 0.28 10iH TSP 8.00 10TH TSP 19 62 05/94 RF0 Bobbin ADI 7.04 71H TSP

+13.72 to +23.97 F/L 05/94 RF0 M/L Special Int VOL 0.65 71H TSP

+33.07 77H TSP 05/94 RF0 H/L Special int VOL 1.03 7TH TSP

+21.26 77H TSP l

05/94 RF0 H/L Special Int VOL 1.03 71H TSP

+29.75 7TH TSP 05/94 RF0 H/L Special Int VOL 1.22 77H TSP

+23.67 7TH TSP 19 67 05/94 RF0 Bobbin 001 36 0.40 10iH TSP

+43.82 F/L 05/94 RF0 C/L Special Int VOL 0.15 9TH TSP

-1.14 9TH TSP 19 86 05/94 RF0 Bobbin ADI 3.0711TH TSP

+7.20 F/L 05/94 RF0 C/L Special Int VOL 0.26 11TH TSP

+7.17 11TH TSP 19 95 05/94 RF0 Bobbin No!

0.25 71H TSP

+23.65 F/L 05/94 RF0 Bobbin N01 0.27 71H TSP

+22.00 F/L 05/94 RF0 Bobbin kQI 0.29 77H TSP

+24.73 F/L 05/94 RF0 Bobbin NQI 0.25 10fH TSP

+24.0L F/L 05/94 RF0 H/L Special Int VOL 0.47 71H TSP

+23.99 7TH ISP 19 97 05/94 RF0 Bobbin No!

0.24 4TH 1SP

+23.66 F/L 19 98 05/94 RF0 Bobbin 001 20 0.79 18TH TSP

+7.33 F/L 19 99 05/94 RF0 Bobbin ODI 28 0.55 187H TSP

+4.00 F/L 19 107 05/94 RF0 Bobbin 001 11 4.91 16TH TSP

+14.72 F/L 05/94 RF0 C/L Special Int VOL 0.90 15TH TSP

-3.42 151H TSP e

20 6 05/94 RF0 Bobbin ADI 6.95 10fH TSP

+34.13 F/L 20 8 05/94 RF0 Bobbin NO!

0.75 17TH TSP

+8.53 F/L 05/94 RF0 r/L Special Int VOL 0.43 171H TSP

+5.53 17TH TSP 20 9 05/94 RF0 Bobbin 001 8

0.49 10!H TSP

+34.43 F/L 20 18 05/94 RF0 Bobbin No!

0.65 12TH TSP

+34.27 F/L 05/94 RF0 Bobbin N01 0.81 121H TSP

+15.25 F/L 05/94 RF0 (/L Specla! Int VOL 0.43 12TH ISP

+15.26 12TH ISP 05/?4 RF0 C/L Special Int VOL 0.46 121H TSP

+34.27 121H TSP 20 20 05/94 RF0 Bobbin ODI 12 1.31 1AVB

+5.36 F/L 20 23 05/94 RF0 Bobbin Nol 1.24 1AVB

+5.98 F/L 05/94 RF0 U-Bend VOL 0.80 1AVB

+5.71 9TH ISP 20 29 05/94 RF0 Bobbin ODI 13 2.84 13fH TSP

+15.56 F/L 20 30 05/94 RF0 Bobbin ADI 4.17 14fH TSP

+4.15 F/L 05/94 RF0 C/L Special Int VOL 0.56 14TH TSP

+4.15 14TH TSP 20 37 05/94 RF0 Bobbin ADI 3.03 5tH TSP

+13.82 F/L 05/94 RF0 Babbin ADI 4.24 STH TSP

+ 11.0 7 F/L 05/94 RF0 H/L Special Int VOL 0.82 51H TSP

+14.05 51H TSP 1

05/94 RF0 H/L Special Int VOL 0.97 $1H TSP

+10.29 STH TSP 20 40 05/94 RF0 Bobbin ADI 4.94 12TH ISP

+11.90 F/L 05/94 RF0 Bobbin 001 15 2.62 12TH TSP

+6.92 F/L 05/94 RF0 C/L Special Int VOL 0.89 121H TSP

+6.80 12TH TSP 05/94 RF0 C/L Special Int VOL 0.55 12iH TSP

+8.32 to +13.22 12fH TSP 20 41 05/04 RF0 Bobbin 001 6

3.03 51H TSP

+24.70 F/L 05/94 RF0 Bobbin 001 13 1.38 51H TSP

+14.57 F/L i

20 46 05/94 RF0 Bobbin ADI 3.00 13TH TSP

-1.77 F/L 05/94 RF0 Bobbin ODI 19 2.59 121H TSP

+24.51 F/L 05/94 RF0 C/L Special Int YOL 0.45 131H TSP 1.77 13fH ISP 20 53 05/94 RF0 Bobbin 001 8

2.96 TTS-HL

+16.09 F/L 20 54 05/94 RF0 Bobbin 001 12 1,29 4TH TSP

+14.85 F/L 05/94 RF0 Bobbin 001 6

0.98 18TH TSP

+13.41 F/L f

05/94 RF0 Bobbin 001 10 1.29 141H TSP

+6.06 F/L 05/94 RF0 Bobbin 001 13 2.26 10TH TSP

+17.41 F/L l

20 55 05/94 RF0 Bobbin C?!

16 0.87197H TSP

+5.05 F/L 20 58 05/94 RF0 Bobbin ODI 7

0.76 10TH TSP + 37.53 F/L 20 61 05/94 RF0 Bobbin ODI 2

0.77 3RD TSP

+ 27.43 F/L 05/94 RF0 Boblin 001 8

0.86 41H TSP

+8.90 F/L 20 68 05/94 RF0 Bobtain 001 3

0.57 181H TSP

+3.51 F/L i

20 70 05/94 RFJ Bobbin ODI 14 0.86 181H ISP

+11.79 F/L

)

05/94 RF0 C/L Spectat Int VOL 0.97 187H TSP

+9.68 18TH TSP i

05/94 RF0 C/L Special Int VOL 1.30 181H TSP

+13.13 18TH TSP

)

20 72 05/94 RF0 Bobbin 001 4

0.58 18TH TSP

+8.33 F/L j

20 73 05/94 RF0 Bobbin 001 18 0.78 181H TSP

+B.22 F/L 1

l

BWNS TUBAN ]! (Version 2.0) 06/17/1994 C6:39:09 eeeeeeeeeeeeeeeeeee*********

Catawba Nuclear Station - Unit Two eeeessessesseeeeeeeesseesses eeeeeeeeeeeeeeeeeeeeeeeeeeee gjg n eeeeeeeeeee*****************

05/94 RF0 eeeee+ee********************

Bobbin,C/L Special Interest,H/L Speclat Interest,H/6 Tubesheet,U Bend Page 13 of 32 S/G D - ATTACHMENT #4 INDICATIONS OF IMPERFECTIONS RDW COL DUTAGE TEST TYPE IND %TW VOLTS LOCATION EXTENT 1 20 74 05/94 Rr0 Bobbin ADI 3.39 BiH TSP

+49.60 F/L 05/94 RF0 Bobbin ADI 4.21 10TH TSP

+35.35 F/L i

05/94 RF0 Bobbin ADI 5.39 14TH TSP

+3.03 F/L 05/94 RF0 Bobbin ADI 7.50 12TH TSP

+37.71 F/L 05/94 RF0 Bobbin 001 4

1.71 4TH TSP

+37.72 F/L 05/94 RF0 Bobbin 001 24 0.77 4TH TSP

+27.25 F/L 05/94 RF0 C/L Special Int VOL 0.56 11TH TSP

-5.11 11TH TSP 05/94 RF0 C/L Special Int VOL 0.75 14TH TSP

+3.03 14TH TSP 05/94 RF0 C/L Special Int VOL 0.38 91H TSP

-11.70 to

-6.61 97H TSP 20 75 05/94 RF0 Bobbin 001 33 0.52 181H TSP

+8.37 F/L 20 78 05/94 RF0 Bobbin 001 17 1.25 10TH TSP

+20.17 F/L 20 80 05/94 RF0 Bobbin ODI 9

2.32 10TH TSP

+7.67 F/L 20 81 05/94 RF0 Bobbin 001 28 0.57 18TH TSP

+8.64 F/L 20 82 05/94 RF0 Bobbin 001 18 0.54 1BTH TSP

+7.91 F/L 20 83 05/94 RF0 Bobbin 001 28 0.40181H TSP

+7.91 F/L 20 84 05/94 RF0 Bobbin 001 13 0.59 18TH TSP

+9.47 F/L 05/94 RF0 C/L Special Int VOL 1.53 1BTH TSP

+10.96 18tH TSP 20 90 05/94 RF0 Bobbin NOI 0.42 1BTH TSP

+5.79 F/L 20 91 05/94 RF0 Bobbin N01 0.36 18TH TSP

+9.17 F/L 20 92 05/94 RF0 Bobbin 001 31 0.66 18TH TSP

+6.63 F/L 20 93 05/94 RF0 Bobbin 001 7

0.58 18TH TSP

+9.0' F/L 05/94 RF0 C/L Special Int VOL 0.69 1BTH TSP

+9.e3 181H TSP 20 94 05/94 RF0 Bobbin 001 24 0.58 1STH TSP

+9.22 F/L 20 96 05/94 RF0 Bobbin DDI 19 1.1718TH TSP

+7.92 F/L 05/94 RF0 C/L Special Int VOL 0.88 1BTH TSP

+8.81 181H TSP 20 98 05/94 RF0 Bobbin 001 2

1.67187H TSP

+9.23 F/L l

05/94 RF0 C/L Special Int VOL 1.44 181H TSP

+10.50 18TH TSP 20 99 05/94 RF0 Bobbin 001 15 0.55 18TH TSP

+9.09 F/L

?0 100 05/94 RF0 Robbin 001 28 0.78 18TH TSP

+9.08 F/L 20 101 05/94 RF0 Bobbin ADI 3.44 18TH TSP

+9.02 F/L 05/94 RF0 C/L Special Int VOL 0.13 181H TSP

+9.56 18TH TSP 20 102 05/94 WF0 Bobbin 001 33 0.72 181H TSP

+9.44 F/L 05/94 RFO C/L Special Int VOL 0.82 18TH TSP

+9.83 187H TSP 20 103 05/94 RF0 Bobbin ODI 36 0.88 181H TSP

+9.11 F/L 05/94 RF0 C/L Special Int VOL 0.61 181H TSP

+9.50 18Th TSP 20 104 05/94 RTO Bobbin 001 23 1.19 181H TSP

+9.35 F/L 20 105 05/94 RfD Bobbin ODI 22 0.81 18TH TSP

+6.64 F/L 20 106 05/94 RF0 Bobbin ADI 2.41 1ST TSP

+24.36 F/L 05/94 RF0 Bobbin 001 25 0.54 18TH TSP

+ 7. 82 F/L 05/94 RF0 H/L Special Int VOL 0.66 2ND TSP

-4.44 2ND TSP 20 107 05/94 RF0 Bobbin 001 3

1.51 18TH TSP

+9.40 F/L 20 108 05/94 RF0 Bobbin ODI 34 0.31 18TH TSP

+9.54 F/L 20 110 05/94 RF0 Bobbin 001 14 0.86 181H TSP

+4.20 F/L 21 5 05/94 RF0 Bobbin ODI 20 1.92 6TH TSP

+28.37 F/L 21 9 05/94 RF0 Bobbin 00!

2.70 1ST TSP

+9.22 F/L 21 13 05/94 RF0 Bobbin 001 12 2.91 2ND TSP

+17.03 F/L 21 14 05/94 RF0 Bobbin 001 3

3.21 18TH TSP

+15.00 F/L 21 15 05/94 RF0 Bobbin 001 37 0.96 10TH TSP

+10.09 F/L 05/94 RF0 C/L Special Int VOL 0.51 10TH TSP

+9.45 10TH TSP 21 17 05/94 RF0 Bobbin ADI 3.21 1ST TSP

+15.97 F/L 05/94 RF0 N/L Speclat Int VOL 0.92 1ST TSP

+16.09 iST TSP 21 18 05/94 RF0 Bobbin ADI 2.36 15fH TSP

+15.93 F/L 05/94 RF0 C/L Specist Int VOL 0.52 15TH TSP

+15.93 15fH TSP 21 20 05/94 RF0 Bobbin ADI 2.77 71H TSP

+29.74 F/L 05/94 RF0 Bobbin ADI 3.37 7TH TSP

+21.17 F/L 05/94 RF0 Bobbin ADI 5.04 12TH TSP

+32.09 F/L 05/94 RFC H/L Special Int VOL 0.70 71H TSP

+29.17 71H TSP 05/94 RF0 H/L Special Int VOL 0.73 71H TSP

+20.72 7TH TSP 05/94 RF0 C/L Special Int VOL 0.82 11TH TSP

-11.76 11TM TSP 21 21 05/94 RF0 Bobbin ADI 1.62 71H TSP

+36.30 F/L 05/94 RFO Bobbin ADI 4.62 16TH TSP

+13.74 F/L 05/94 RF0 Bobbin 001 6

1.62 7TH TSP

+27.41 F/L 05/94 RF0 Bobbin DDI 4

2.?8 12TH TSP

+28.51 F/L 05/94 RF0 Bobbin 001 6

3.51 13TH TSP

+24.80 F/L 05/94 RF0 Bobbin 001 13 2.0211TH TSP

+3.35 F/L 05/94 RF0 sobbin 001 13 2.65 14TH TSP

+5.73 F/L

...........eee..e**********

BWNS TUBAN II (version 2.0) 06/17/1994 06:39:09 eeeeeeeeeeeeeeeeeeeeeeeee***

Catawba Nuclear Station Unit Iwo eeeeee.................****

3/G D eeeeet....................**

05/94 Rt0 Bobbin,C/L Special Interest,H/L Spectat Interest,H/L Tubesheet,U-Bend Page 14 of 32

$/G D - ATTACHMENT #4 INDICAtl0NS OF IMPERFECTIONS RDW COL DUTACE TEST TYPE INO %1W VOLTS LOCAi!ON EXTENT 1 05/94 RF0 H/L Special Int VOL 0.29 81H TSP

-6.40 81H TSP 05/94 RF0 C/L Special Int VOL 0.40 161H ISP

+13.66 16TH TSP 05/94 RF0 C/L Special Int VOL 0.87 161H ISP

+13.65 16TH TSP 21 30 05/94 RF0 Bobbin 001 34 0.32 13fH TSP

+31.35 F/L 21 31 05/94 RF0 Bobbin A01 3.00 6TH ISP

+30.94 F/L 05/94 RF0 H/L Special Int VOL 0.49 7TH TSP 10.93 7TH TSP 21 33 05/94 RF0 Bobbin ODI 11 4.03 1AVB

+13.21 F/L 05/94 RF0 Bobbin 001 16 0.73 51H ISP

+19.31 F/L 21 36 05/94 RF0 Bobbin 001 5

1.25 71H ISP

+37.01 F/L 21 47 05/94 RF0 Bobbin 001 18 2.05 161H TSP

+15.20 F/L 21 49 05/94 RF0 Bobbin A01 2.89 13fH ISP

+8.16 F/L 05/94 RF0 C/L Speclat Int VOL 0.36 13fH TSP

+8.80 13fH TSP 21 52 05/94 RF0 Bobbin 001 4

1.34 13f H TSP

+23.00 F/L 21 54 05/94 RF0 Bobbin A01 1.08 17TH TSP

+12.36 F/L 05/94 RFO C/L Special Int VOL 0.26 177H TSP

+12.76 17IH TSP 05/94 RFO C/L Speclat Int VOL 0.40 17TH TSP

+2.00 17IN TSP 21 61 05/94 RF0 Bobbin 001 14 0.65 171H TSP 6.29 F/L 21 63 05/94 RFO Bobbin 001 29 0.51 177H TSP

-4.14 F/L 21 65 05/94 RF0 Dobbin 001 14 0.65 181H TSP

+13.49 F/L 21 66 05/94 RF0 Bobbin 001 27 0.68 187H TSP

+15.43 F/L 21 68 05/94 RF0 Bobbin 001 14 0.96 177H ISP

-7.22 F/L l'

69 05/94 RF0 Bobbin 001 14 1.34 187H TSP

+13.60 F/L 24 73 05/94 RF0 Bobbin 001 22 0.52 181H TSP

+13.01 F/L ft 74 05/94 RF0 Bobbin 001 29 0.82 18TH TSP

+11.39 F/L (1 76 05/94 RF0 Bobbin 001 13 0.95 181H TSP

+14.00 F/L l

21 77 05/94 RF0 Bobbin 001 16 1.22 18TH ISP

+11.11 F/L l

21 79 05/94 RF0 Bobbin 001 3

1.58171H ISP

-4.24 F/L l

05/94 RF0 C/L Special Int VOL 1.37 17TH ISP

-4.44 171H ISP l

21 80 05/94 RF0 Bobbin 001 28 0.56 18tH TSP

+12.21 F/L 21 81 05/94 RF0 Bobbin 001 9

1.38 181H TSP

+12.30 F/L 21 82 05/94 RF0 Bobbin 001 25 0.8718TH ISP

+12.06 F/L 21 83 05/94 RF0 Bobbin 001 11 2.20171N TSP 6.11 F/L 21 84 05/94 RF0 Bobbin 001 8

0.77 18TH TSP

+12.43 F/L 21 85 05/94 RF0 Bobbin 001 23 0.94 181H TSP

+12.39 F/L 21 87 05/94 RF0 Bobbin 001 4

0,55 191H ISP 5.35 F/L 05/94 RTO Bobbin 001 22 1.04 181H ISP

+12.32 F/L 05/94 RF0 C/L Special Int VOL 0.77171H TSP

-6.42 17TH ISD 21 88 05/94 RF0 Bobbin 001 9

1.09 13fH TSP

+12.36 F/L 05/94 RFC Bobbin 001 19 0.32 1BTH ISP

+1.78 F/L 05/94 RF0 Bobbin 001 24 0.26 181H TSP

+2.51 F/L 21 89 05/94 RF0 Bobbin 001 3

1.11 181H ISP

+12.57 F/L 21 90 05/94 RF0 Bobbin 001 13 1.43 18TH TSP

+12.66 F/L 21 91 05/94 RF0 Bobbin 001 12 0.82 17TH TSP 5.63 F/L 21 92 05/94 RF0 Bobbin 001 1

1.93 17TH TSP

5. 73 F/L 21 93 05/94 RF0 Bobbin ADI 2.47 11rH ISP

+30.94 F/L 05/94 RF0 Bobbin ODI 15 0.72 181H TSP

+12.56 F/L l

05/94 RIO Dobbin ADI 3.72 11TH TSP

+11.73 to +23.23 F/L 05/94 RF0 C/L Special Int VOL 0.22 111H ISP

+15.56 11TH TSP 05/94 RF0 C/L Special Int VOL 0.24 11TH TSP

+13.48 11TH ISP 05/94 RF0 C/L Speclat Int Vot 0.25 11TH ISP

+12.45 11TH TSP 05/94 RF0 C/L Spectat Int VOL 0.32 11TH TSP

+20.12 111H ISP 05/94 RF0 C/L Special Int VOL 0.49 111H TSP

+14.10 111H TSP 05/94 RF0 C/L Special Int VOL 0.52 111H ISP

+23.20 11TH TSP 05/94 RF0 C/L Special Int VOL 0.65 111H TSP

+30.91 111H TSP 05/94 RF0 C/L Special Int VOL 0.70 11TH TSP + 17.4 7 111H TSP 21 94 05/94 RF0 Bobbin NQI 0.30 1BTH TSP

+2.30 F/L 05/94 RF0 Bobbin 001 11 1.61 187H TSP

+12.40 F/L 21 96 05/94 RF0 Bobbin No!

0.19 18TH TSP

+8.01 F/L 05/94 RF0 Bobbin 001 8

1.43 181H TSP

+12.82 F/L 21 97 05/94 RF0 Bobbin ODI 2

1.29 181H ISP

+2.70 F/L 21 99 05/94 RF0 Bobbin 001 24 1.28 18TH TSP

+2.72 F/L 21 101 05/94 RF0 Bobbin 001 6

2.20 181H TSP

+2.91 F/L 21 102 05/94 RF0 Botbin 001 1

1.29 18TH TSP

+2.87 F/L 21 103 05/94 RF0 Bobbin 001 35 0.96 187H ISP

+2.39 F/L 21 104 05/94 RF0 Bobbin 001 17 1.14 18TH TSP

+3.24 F/L 21 105 05/94 RF0 Bobbin 001 4

1.86 81H TSP

+26.40 F/L I

eeeeeeeee*******************

BWNS TUBAN !! (Version 2.0) 06/17/1994 D6:39:09 e eeee**********************

Catawba Nuclear Station - Unit Two

......e....**..........*****

sfg n e e*************************

05/94 RF0

  • eeeeee......****...********

Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U-Bend Page 15 of 32 S/G D - ATTACHMENT #4 INDICATIONS OF IMPERFECTIONS fiOW COL OUTAGE TEST TYPE IND %TW VOLTS 10 CATION EXTENT 1 05/94 RF0 Bobbin 001 33 1.04 18TH TSP

+2.76 F/L 05/94 RF0 U Bend VOL 1.61 BTH TSP

+24.03 8TH TSP 21 108 05/94 RF0 Bobbin 001 2

1.58 18TH TSP

+2.62 F/L 21 110 05/94 RF0 Bobbin ODI 13 1.12 18TH TSP

+3.17 F/L 05/94 RF0 C/L Special Int VOL 0.65 18TH TSP

+3.00 18TH TSP 22 8 05/94 RF0 Bobbin 001 7

1.94 13TH TSP

+31.56 F/L 05/94 RF0 Bobbin 001 15 3.89 11TH TSP

+38.37 F/L 22 9 05/94 RF0 Bobbin ADI 1.64 14TH TSP

+9.70 F/L 05/94 RFO Bobbin ADI 2.79 11TH TSP

+26.98 F/L 22 13 05/94 RF0 Bobbin ADI 2.5710TH TSP

+32.34 F/L 05/94 RF0 Bobbin 001 19 0.40 77H TSP

+23.69 F/L 22 16 05/94 RF0 Bobbin ADI 1.53 10TH TSP

+37.72 F/L 22 27 05/94 RF0 Bobbin 001 32 0.85 16TH TSP

+11.03 F/L 22 30 05/94 RF0 Bobbin 001 19 0.77 18TH TSP

+13.46 F/L 22 33 05/94 RF0 Bobbin ADI 1.50 13TH TSP

+24.59 F/L 05/94 RF0 Bobbin ADI 1.54 13fH TSP

+21.73 F/L 05/94 RF0 C/L Special Int VOL 0.18 13TH TSP

+24.60 13TH TSP 05/94 RF0 C/L Special Int VOL 0.19 137H TSP

+21.51 13TH TSP 22 36 05/94 RF0 Bobbin ADI 3.39 4TH TSP

+30.66 F/L 05/94 RF0 H/L Special Int VOL 0.69 STH TSP

-12.40 STH TSP 22 40 05/94 RF0 Bobbin 001 11 1.10 16TH TSP

+11.59 F/L 22 70 05/94 RF0 Bobbin ADI 2.19 15TH TSP

+1.50 F/L 05/94 RF0 Bobbin ADI 4.5714TH TSP

-8.53 F/L 05/94 RF0 C/t Special Int VOL 0.25 14TH TSP 6.63 14TH TSP 05/94 RF0 C/L Special Int VOL 0.36 15TH TSP

+1.19 15TH TSP 05/94 RF0 C/L Special Int VOL 0.4714TH TSP

-9.07 14TH TSP 22 74 05/94 RF0 Bobbin ADI 8.14 10TH TSP

+4.59 F/L 05/94 RF0 C/L Special Int VOL 0.57 10TH TSP

+4.31 10TH TSP 22 75 05/94 RF0 Bobbin ADI 9.34 4TH TSP

+23.29 F/L 05/94 RF0 H/L Special Int VOL 1.43 4TH TSP

+23.79 4TH TSP 22 81 05/94 RF0 Bobbin ADI 1.93 2ND TSP

+28.32 F/L 05/94 RF0 H/L Special Int VOL 0.54 3RD TSP

-7.71 3RD TSP 22 89 05/94 RF0 Bobbin 001 6

1.17 8TH TSP

-1.01 F/L 05/94 RF0 Bobbin 001 11 1.90 6TH TSP

-8 45 F/L 05/94 RF0 Bobbin ODI 27 0.37 7TH TSP

+40.47 F/L 22 01 05'94 RF0 Bobbin ADI 2.34 13TH TSP

+15.32 F/L 05/94 RF0 Bobbin NOI 0.41 13TH TSP

+18.46 F/L 05/94 RF0 C/L Special Int VOL 0.16 137H TSP

+18.75 13TH TSP 22 92 05/94 RF0 Bobbin NQI 0.75 131 TSP

+24.68 F/L 05/94 RFO Bobbin 001 20 1.16 1ST TSP

+ 7. 5 7 F/L 05/94 RF0 H/L Special Int VOL 0.59 2ND TSP

-3.79 2ND TSP 22 93 05/94 RF0 Bobbin ADI 3.81 STH TSP

+34.28 F/L 05/94 RF0 H/L Special Int VOL 1.03 6TH TSP

-8.77 6TH TSP 22 102 05/94 RF0 Bobbin 001 11 1.84 13fH TSP

+17.46 F/L 23 9 05/94 RF0 Bobbin ADI 1.34 7TH TSP

+37.74 F/L 05/94 RFO Bobbin ADI 2.79 1ST TSP

+20.90 F/L 05/94 RF0 H/L Special Int VOL 0.59 2ND TSP

-6.88 2ND TSP 23 11 05/94 RF0 Bobbin ODI 8

3.07 4TH TSP

+17.33 F/L 23 12 05/94 RF0 Bobbin 001 20 1.21 7TH TSP

+37. 60 F/L 23 18 05/94 RF0 Bobbin 001 10 1.46 BTH TSP

-1.95 F/L 23 25 05/94 RF0 Bobbin 001 14 0.95 11TH TSP

+26.62 f/L 23 28 05/94 RF0 Bobbin ADI 2.89 Sih TSP

+20.98 to +28.48 F/L 05/94 RF0 H/L Special Int VOL 0.14 STH TSP

+21.?8 STH TSP 05/94 RF0 H/L Special Int VOL 0.26 STH TSP

+24.59 STH TSP 05/94 RF0 N/L Special Int VOL 0.28 STM TSP

+27.15 STH FSP 05/94 RF0 H/L Special Int VOL 0.30 STH TSP

+23.73 STH TSP 23 34 05/94 RF0 Bobbin ADI 2 89 137H TSP

+7.97 F/L g

05/94 RF0 C/L Spectat Int VOL 0.26 13TH TSP

+7.98 13TH TSP 23 39 05/94 RF0 Bobbin ADI 4.68 14TH TSP

+13.94 F/L 05/94 RF0 C/L Special Int VOL 0.33 14TH TSP

+15.06 14TH TSP 05/94 RF0 C/L Special Int VOL 0.38 14TH TSP

+13.25 14TH TSP 23 45 05/94 RF0 Bobbin 001 6

1.24 7TH TSP

+28.25 F/L 05/94 RF0 Bobbin 001 8

4.50 7TH TSP

+1.90 F/L 05/94 RF0 Bobbin 001 10 5.16 81H TSP

+9.50 F/L 05/94 RF0 Bobbin 001 11 2.77 7TH ISP

+34.24 F/L 23 99 05/94 RF0 Bobbin N01 0.28 91H TSP

-6.70 F/L

ee**************************

BWNS TUBAN 11 (version 2.0) 06/17/1994 06:39:09 esee *eeeee*****************

Catawba Nuclear Station - Unit Two S/G 0 eeeeee......

e*************

05/94 RF0 Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U-Bend Page 16 of 32 S/G D - ATTACHMENT #4 INDICATIONS OF IMPERFECTIONS ROW COL OUTAGE TEST TYPE IND %TW VOLTS LOCATION EXTENT 1 05/94 RF0 Bobbin 001 16 0.54 177H TSP 9.06 F/L 05/94 RF0 C/L Speclet Int VOL 0.81 9TH TSP

-5.45 97H TSP 23 101 05/94 RF0 Bobbin 001 2

1.81 10TH TSP

+24.34 F/L 23 103 05/94 RF0 Bobbin 001 30 1.27 97H TSP

-2.34 F/L 05/94 RF0 C/L Special Int VOL 0.37 9TH TSP

-2.69 97H TSP 05/94 RF0 C/L Special Int VOL 0.41 91H TSP

-1.39 9TH TSP 05/94 RF0 C/L Special Int VOL 0.59 9TH TSP

-2.62 9TH TSP 23 106 05/94 RF0 Bobbin NQI 0.73 14TH TSP

+8.70 F/L 05/94 RF0 C/L Special Int VOL 0.78 14TH TSP

+8.56 14TH TSP 23 108 05/94 RF0 Bobbin ADI 4.55 11TH TSP

+12.13 F/L 23 109 05/94 RF0 Bobbin ADI 3.25 16TH TSP

-5.26 F/L 05/94 RFO C/L Special Int VOL 0.35 16TH ISP

-5.82 16TH TSP 24 7 05/94 RF0 Bobbin 001 31 2.23 7TH TSP

+7.21 F/L 05/94 RF0 Bobbin 001 19 2.12 11TH TSP

+2.22 F/L 24 8 05/94 RF0 Bobbin 001 3

3.04 6TH TSP

+25.50 F/L 24 10 05/94 RF0 Bobbin ADI 3.04 157 TSP

+11.44 F/L 05/94 RF0 Bobbin ADI 5.68 1ST TSP

+4.17 F/L 05/94 RF0 H/L special Int VOL 0.21 IST TSP

+11.44 IST TSP 05/94 RF0 H/L Special Int VOL 0.92 1ST TSP

+4.15 1ST TSP 24 13 05/94 RF0 Bobbin ADI 2.33 14TH TSP

+13.86 F/L 05/94 RF0 Bobbin ADI 2.40 18tH TSP

+10.25 F/L 05/94 RF0 Bobbin ADI 3.33 171H TSP

+10.67 F/L 05/94 RF0 C/L Special Int VOL 0.24 18TH TSP

+10.25 18TH TSP 05/94 RF0 C/L Special Int VOL 0.27 13fH TSP

-4.66 13fH TSP 05/94 RF0 C/L Special Int VOL 0.56 177H TSP

+10.67 17TH TSP 24 18 05/94 RF0 Bobbin 001 6

2.92 2ND TSP

+26.52 F/L 05/94 RF0 Bobbin 001 8

1.34 11TH TSP

+25.02 F/L 05/94 RF0 H/L Special Int VOL 0.95 3RD TSP

-9.34 3RD TSP 24 19 05/94 RF0 Bobbin 001 14 2.69 13fH TSP

+29.69 F/L 05/94 RF0 C/L Special Int VOL 0.82 12TH TSP

-10.95 12TH TSP 24 28 05/94 RF0 Bobbin ADI 5.87 12TH TSP

-1.57 F/L 05/94 RF0 Bobbin NQ1 0.87 13fH TSP

+22.99 F/L 05/94 RF0 Bobbin DDI 1

2.21 7TH TSP

+21.19 F/L 05/94 RF0 C/L Special Int VOL 0.51 12TH TSP

-1.57 12TH TSP 05/94 RF0 C/L Special Int VOL 0.78 12TH TSP

-21.02 12TH TSP 24 32 05/94 RF0 Bobbin ADI 3.61 13fH TSP

+18.02 F/L 24 37 05/94 RF0 Bobbin NQI 0.61 97H TSP

-0.80 F/L 05/94 RF0 C/L Special Int VOL 0.43 91H TSP

-1.00 9TH TSP 24 47 05/94 RFC Bobbin ADI 2.11 19TH TSP

+2.13 F/L 05/94 RF0 C/L Special Int VOL 0.44 19TH TSP

+2.38 197H TSP 24 51 05/04 RfD Bobbin 001 8

1.14 16TH TSP

+5.82 F/L 24 60 05/94 RF0 Bobbin Nol 1.36 7TH TSP

+23.08 F/L 05/94 RF0 H/L Special Int VOL 2.04 7TH TSP

+22.64 77H TSP 24 62 05/94 RF0 Bobbin NQI 0.46 11TH TSP

-0.82 F/L 05/94 RF0 C/L Special Int VOL 0.59 11TH TSP 0.88 11TH TSP 24 71 05/94 RF0 Bobbin ADI 2.93 13TH TSP

+13.36 F/L 05/94 RF0 Bobbin NQ1 0.93 13fH TSP

+10.19 F/L 05/94 RF0 C/L Specist Int VOL 0.69 13TH TSP

+12.04 13TH TSP 05/94 RF0 C/L Special Int VOL 0.80 13TH TSP

  • 13.29 13TH TSP 05/94 RF0 C/L Special Int VOL 0.96 131H TSP

+10.55 13TH TSP 24 72 05/94 RF0 Bobbin 001 13 1.08 10TH TSP

+36.19 F/L 24 79 05/94 RF0 Bobbin 001 7

1.38 17TH TSP

+12.47 F/L 24 86 05/94 RF0 Bobbin 001 11 1.18 4TH TSP

+10.47 F/L 05/94 RF0 Bobbin 001 16 1.74 10TH TSP

+39.34 F/L 24 91 05/94 RF0 Bobbin NQ1 0.43 16TH TSP

+8.75 F/L 05/94 RF0 Bobbin NQI 0.76 17iH TSP

+8.34 F/L I

05/94 RF0 Bobbin 001 13 1.63 17TH TSP

+ 7.17 F/L 05/94 RF0 C/L Special Int VOL 0.23 17TH TSP

+5.56 171H TSP 05/94 RF0 C/L Speclat Int VOL 0.34 16TH 1SP

+8.71 16TH TSP 05/94 RF0 C/L Special Int VOL 0.50 16TH TSP

+9.45 16TH TSP 05/94 RF0 C/L Special Int VOL 0.81 17TH TSP

+ 7.13 17TH TSP 05/94 RF0 C/L Special Int VOL 0.81 17TH TSP

+8.26 17TH TSP 24 102 05/94 RF0 Bobbin 001 20 1.55 11TH T$P

+28.72 F/L 24 103 05/94 RF0 Sobbin ADI 3.0517TH TSP

+6.27 F/L 05/94 RF0 Bobbin DDI 3

1.36 17TH TSP

+2.75 F/L 05/94 RF0 C/L Special Int VOL 0.32 171H TSP

+3.01 171H TSP i

l BWNS TUBAN 11 (Version 2.0) 06/17/1994 ',6:39:09 1.eeeeeeeeeeeee..eeeeeeeeen Catawba Nuclear Station - Unit Two e......................****

S/G D eee.........................

05/94 RF0 Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U-Bend f

$/G D - ATTACHMENT #4 INDICATIONS OF IMPERFECTIONS

[

ROW COL OUTAGE TEST TYPE IND 1.TW VOLTS LOCAil0N EXTENT 1 24 104 05/94 RF0 Bobbin ADI 4.30 11TH TSP

+2.16 to +29.24 F/L 05/94 RF0 C/L Special Int VOL 0.78 111H TSP

+ 2.16 t o +29.24 11TH TSP

[

24 105 05/94 RF0 Bobbin ADI 2.36 131H TSP

+35.78 F/L t

05/94 RF0 Bobbin ADI 2.89 13TH TSP

+22.89 F/L 05/94 RF0 C/L Special lot VOL 0.3712TH TSP

-9.49 12TH TSP 05/94 RF0 C/L Speclat Int VOL 0.37 12TH TSP

-20.55 12TH TSP 05/94 RF0 C/L Speclat Int VOL 0.49 12TH TSP

-6.28 12TH TSP 05/94 RF0 C/L Special Int VOL 0.62 12TH TSF

-7.76 12TH TSP

[

24 106 05/94 RF0 Sobbin NQI 1.12 4TH TSP

+4.78 F/L 05/94 RF0 Bobbin ADI 2.37 14TH TSP

+8.93 F/L 05/94 RF0 Bobbin ADI 2.40 1STH T$P

-2.36 F/L 05/94 RF0 H/L Special Int V0t 1.05 4TH TSP

+5.36 4TH TSP 05/94 RF0 C/L Special Int VOL 0.36 14TH TSP

+9.07 14TH TSP I

05/94 RF0 C/L Special Int VOL 0.46 18TH TSP

-2.63 18TH TSP 25 8 05/94 RF0 Bobbin NQ1 0.66 10TH TSP

+36.39 F/L 05/94 RF0 C/L Special Int VOL 0.34 91H TSP

-8.48 9TH TSP 25 14 05/94 RF0 Bobbin NQ1 0.63 7FH TSP

+28.47 F/L 05/94 RF0 Bobbin NQ1 0.72 7TH TSP

+38.01 F/L 05/94 RF0 Bobbin 001 2

1.13 71H TSP

+24.63 F/L 05/94 RF0 H/L Special Int VOL 0.37 BTH TSP 14.33 BTH TSP 05/94 RF0 H/L Special Int VOL 0.51 8TH TSP

-4.15 BTH TSP 05/94 RF0 H/L Special Int VOL 0.64 81H TSP

-5.44 BTH TSP 25 16 05/94 RFO Bobbin ODI 13 1.94 10TH TSP

+33.70 F/L 25 21 05/94 RF0 Bobbin ADI 4.11 1AVB

+0.97 F/L 05/94 RF0 Bobbin ODI 15 2.93 3AVB

-2.65 F/L 05/94 RF0 Bobbin 001 14 1.65 7TH TSP

+27.45 F/L 25 23 05/94 RF0 Bobbin 001 8

1.19 10TH TSP

+40.21 F/L 05/94 RF0 C/L Special Int VOL 0.90 9TH TSP 6.36 9TH TSP 25 30 05/94 RF0 Bobbin 001 1

2.13 10TH TSP

+33.48 F/L 25 34 05/94 RF0 Bobbin 001 26 1.17 6TH TSP

+36.38 F/L 25 40 05/94 RF0 Bobbin ADI 2.41 12TH TSP

  • 14.18 F/L 05/94 RF0 Bobbin 001 13 1.6712TH TSP

+23.98 F/L 05/94 RFC C/L Special Int VOL 0.31 12TH TSP

+14.13 12TH TSP 25 45 05/94 RF0 Bobbin 001 7

1.15 131H TSP

+18.75 F/L 05/94 RF0 Bobbin ODI 17 1.30 16TH TSP

+2.48 F/L 05/94 RF0 C/L Specist Int Vbt 0.34 16TH TSP

+2.11 16TH TSP 25 51 05/94 RF0 Bobbin ODI 8

1.32 6TH TSP

+4.54 F/L 05/94 RF0 Bobbin ODI 15 1.1715TH TSP

+9.69 F/L 25 56 05/94 RF0 Bobbin ADI 4.35 11TH TSP

+34.50 F/L l

05/94 RIO Bobbin 001 17 1.68 12TH TSP

+6.21 F/L 05/94 RF0 C/L Special Int Vot 0.37 10TH TSP

-8.24 10TH TSP I

05/94 RF0 C/L Special Int VOL 0.51 10TH TSP 9.76 10TH TSP 25 62 05/94 RF0 Bobbin ADI 4.92 4AVB

-18.51 F/L 05/94 RF0 Bobbin 001 7

1.43 4TH TSP

+32.01 F/L 05/94 RF0 Bobbin ODI 12 1.58 2ND TSP

  • 13.52 F/L 25 63 05/94 RF0 Bobbin ADI 9.23 3AVB

-10.25 F/L 25 71 05/94 RF0 Bobbin ADI 3.83 12TH TSP

+7.37 F/L 05/94 RF0 C/L Special Int VOL 0.37 12TH TSP

+7.26 12TH TSP 25 78 05/94 RF0 Bobbin ADI 3.77 15TH TSP

-6.13 F/L 05/94 RF0 C/L Special Int VOL 0.74 15fH 1SP

-6.13 15TH TSP 25 80 05/94 RF0 Bobbin ADI 4.83 STM TSP

+28.05 F/L 05/94 RF0 H/L Special Int VOL 0.45 Sik TSP

+26.67 STH TSP I

05/94 RF0 H/L Special Int VOL 0.83 51H TSP

+27.78 to +29.89 STH TSP 25 86 05/94 RF0 Bobbin ADI 7.09 2AVB

+10.97 F/L 05/94 RF0 U Bend VOL 0.58 1AVB

+11.15 3AVB 25 91 05/94 RF0 Bobbin ODI 7

1.3712TH TSP

+1.93 F/L 05/94 RF0 Bobbin 001 15 2.20 12TH TSP

+1.22 F/L 25 96 05/94 RF0 Bobbin ADI 2.69 16TH TSP

+12.59 F/L 05/94 RF0 Bobbin ADI 4.59 10TH TSP

+16.30 F/L 05/94 RF0 Bobbin 001 20 1.24 15fH TSP 5.01 F/L 05/94 RF0 C/L Speclet Int VOL 0.20 10TH TSP

+17.18 10TH TSP 05/94 RF0 C/L Speclat Int VOL 0.69 15fH TSP

-6.23 151H TSP 25 103 05/94 RF0 Botbin ADI 4.99 PND TSP

-2.80 F/L 05/94 RF0 Bobbin ADI 5.75 2ND 1SP

+4.55 F/L 05/94 RF0 Bobbin 001 11 0.81 12TH TSP

+16.95 F/L 05/94 RF0 H/L Special int VOL 0.24 2ND TSP

-2.61 2ND TSP

eeeeee**********************

BWNS TUBAN ll (Version 2.0) 06/17/1994 06:39:09 Catawba Nuclear 3tation - Unit Two S/G 0 05/94 RF0 Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U Bend e.e.... ********************

Page 18 of 32 S/G D - ATTACHMENT #4 INDICATIONS OF IMPERFECTIONS ROW COL DUTAGE TEST TYPE IND %TW VOLTS LOCATION EXTENT 1 05/94 RF0 N/L Special Int VOL 0.44 2ND TSP

-2.76 2ND TSP 05/94 RF0 H/L Special Int VOL 0.49 2ND TSP

+5.20 2ND TSP i

25 105 05/94 RF0 Bobbin NOI 0.93 17TH TSP

-2.98 F/L 05/94 RF0 C/L Special Int VOL 0.68 171H TSP

-2.92 171H TSP 25 107 05/94 RF0 Bobbin WAR 23 1.12 2AVB

+0.00 F/L 25 108 05/94 RF0 Bobbin ADI 3.43 13TH TSP

+11.77 F/L 05/94 RF0 C/L Special Int VOL 0.45 13TH TSP

+11.64 13TH TSP 26 9 05/94 RFC Dobbin NQI 0.71 12TH ISP

+17.05 F/L 05/94 RF0 Bobbin ODI 5

1.11 10TH TSP

+24.17 F/L 05/94 RF0 C/L Special Int VOL 0.76 121H TSP

+17.05 121H TSP 26 10 05/94 RF0 Bobbin 001 5

1.77 7TH TSP

+32.08 F/L 26 14 05/94 RF0 Bobbin 001 2

1.11 TTH TSP

+28.54 F/L 26 18 05/54 RF0 Bobbin Noi 0.55 12TH TSP

+30.49 F/L 05/94 RF0 C/L Special Int VOL 0.59 11TH TSP

-10.67 11TH TSP 26 19 05/94 RF0 Bobbin 001 5

1.95 3RD TSP

+28.69 F/L 05/94 Rio Bobbin 001 8

2.98 3RD TSP

+32.85 F/L 05/94 RF0 Bobbin 001 12 0.78 4TH TSP

+4.79 F/L 05/94 RF0 Bobbin 001 10 2.10 10TH TSP

+22.97 F/L 05/94 RF0 N/L Special Int VOL 0.33 4TH TSP

+4.19 4TH TSP 05/94 RF0 H/L Special Int VOL 0.38 4TH TSP 6.88 4TH TSP 05/94 RF0 H/L Special Int VOL 0.82 4TH TSP

-2.94 4TH TSP 05/94 RF0 C/L Special Int VOL 0.32 10TH TSP

+22.93 10TH TSP 26 23 05/94 RF0 Bobbin 001 8

4.23 71H ISP

+31.63 F/L l'

26 25 05/94 RF0 Bobbin 001 7

1.86 STH TSP

+30.27 F/L 26 27 05/94 RF0 Bobbin NQI 1.08 4TH TSP

+12.18 F/L 05/94 RF0 H/L Special Int VOL 1.19 4TH TSP

+11.85 4TH ISP 26 28 05/94 RF0 Bobbin 001 16 1.33 16TH TSP

+4.64 F/L 05/94 RF0 C/L Special Int VOL 0.52 16TH TSP

+4.27 16TH TSP 26 32 05/94 RF0 Bobbin ADI 2.72 7TH ISP

+16.33 F/L 05/94 RF0 H/L Special Int VOL 0.60 71H TSP

+16.33 7TH TSP 26 36 05/94 RF0 Bobbin ODI 10 1.41 6TH TSP

+ 30. 3 7 F/L 26 37 05/94 RF0 Bobbin 001 7

1.39 10TH TSP

+38.60 F/L 26 39 05/94 RF0 Bobbin DDI 11 2.02 STH TSP

+B.40 F/L 05/94 RF0 Bobbin 001 25 0.72 7TH TSP

+36.5m F/L 26 42 05/94 RF0 Bobbin 001 20 0.86 STH TSP

+15.20 F/L 26 45 05/94 RF0 Bobbin ODI 15 2.04 TTH TSP

+36.73 F/L 05/94 RF0 Bobbin 001 3

1.07 10TH TSP

+32.09 F/L 05/94 RF0 C/L Special Int VOL 0.30 9TH TSP

-4.21 9TH ISP 05/94 RF0 C/L Special Int VOL 0.31 9TH TSP

-2.95 91H TSP 05/94 RF0 C/L Special Int VOL 0.38 9TH TSP

-1.55 9TH TSP 05/94 RF0 C/L Special Int VOL 0.48 97H TSP

-0.20 9TH TSP 05/94 RF0 C/L Special Int VOL 1.55 9TH TSP 13.21 97H TSP 05/94 RF0 H/L Special Int VOL 0.36 BTH TSP

-5.09 81H TSP 26 46 05/94 RF0 Bobbin 001 2

3.68 3AVB

-3.77 F/L 05/94 RF0 Bobbin 001 10 5.05 4TH TSP

+5.49 F/L 05/94 RF0 Bobbin DDI 5

2.04 12TH ISP

+'O.48 F/L 05/94 RF0 Bobbin ODI 5

5.05 12TH TSP

+t9.95 F/L 05/94 RF0 Bobbin DDI 6

1.91 10TH TSP

+28.98 F/L 05/94 RF0 Bobbin 001 8

2.27 10TH TSP

+ 7.51 F/L 05/94 RF0 Bobbin DD1 12 1.43 10TH TSP

+44.69 F/L 26 56 05/94 RF0 Bobbin ADI 9.07 2AVB

+3.01 F/L j

05/94 RF0 Bobbin ADI 6.60 10TH TSP

+19.07 F/L 05/94 RF0 Bobbin ODI 3

3.15 3RD TSP

+18.53 F/L 05/94 RF0 Bobbin 001 12 4.95 3RD TSP

+20.73 F/L 1

05/94 RFO C/L Special int VOL 0.98 10TH ISP + 17. 53 10TH TSP j

26 59 05/94 RF0 Bobbin No!

0.64 STH TSP

+6.29 F/L 05/94 RF0 H/L Special Int VOL 0.66 STH TSP

+15.44 STM TSP 05/94 RF0 N/L Special Int VOL 0.77 STM TSP

+6.25 STH ISP i

26 67 05/94 RF0 Bobbin ADI 3.5710TH ISP

+13.65 F/L 05/94 RF0 C/L Special Int VOL 1.10 10TH TSP

+12.31 10TH TSP 26 TO 05/94 RF0 Bobbin ADI 2.89 11TH ISP

+22.46 F/L 05/94 RF0 Bobbin ADI 4.09 10TH ISP

+4.97 F/L 05/94 RIO Bobbin ADI 4.70 111H TSP + 36.17 F/L 05/94 RF0 Bobbin ADI 7.17 13TH TSP

+36.86 F/L 05/94 RF0 C/L Special Int VOL 0.13 11TH TSP

+22.48 11TH TSP 05/94 RF0 C/L Special Int VOL 0.38 10TH TSP

-7.72 10TH TSP i

l

BWNS TUBAN !! (Version 2.0) 06/17/1994 06:39:09 Catawba Nuclear Station - Unit Two eseessessessesseesseesseee**

eeeeeeesesessessessee** eese sig n

  • ee.e......e...e..e*********

05/94 RF0 Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U Bend Page 19 of 32 S/G 0 - ATTACHMENT #4 INDICATIONS OF IMP RFECTIONS J

ROW COL DUTAGE TEST TYPE IND %TW VOLTS LOCATION EXTENT 1 05/94 RF0 C/L Spectat Int VOL 0.40 10TH TSP

+5.31 10TH TSP 05/94 RF0 C/L Speclat Int VOL 0.4710TH TSP

+4.65 10TH TSP 05/94 RF0 C/L Special Int VOL 1.15 12TH TSP

-6.41 12TH TSP 26 72 05/94 RF0 Bobbin 001 4

2.54 10TH TSP

+27.54 F/L 26 75 05/94 RF0 Bobbin ADI 5.19 2ND TSP

+11.25 F/L 05/94 RF0 Bobbin ADI 4.35 19TH TSP

+6.35 F/L 26 76 05/94 RF0 Bcbbin ADI 1.8217TH TSP + 15. 75 F/L 05/94 RF0 Bobbin ADI 2.24 12TH TSP

+28.00 F/L 05/94 RF0 Bobbin ADI 2.29 12TH TSP

+35.93 F/L 05/94 RF0 Bobbin ADI 2.90 12TH TSP

+23.05 F/L 05/94 RF0 Bobbin ADI 3.35 13fH TSP

+23.18 F/L 05/94 RF0 Bobbin 001 6

1.79 10TH TSP

+35.35 F/L 05/94 RF0 Bobbin 001 10 1.07 10TH TSP

+31.56 F/L 26 77 05/94 RF0 Bobbin ADI 5.47 BTH TSP

+14.52 F/L 05/94 RF0 U-Bend VOL 0.68 STH TSP

+14.91 BTH TSP 26 80 05/94 RF0 Bobbin ADI 4.21 19TH TSP 6.74 F/L 26 82 05/94 RF0 Bobbin ADI 2.50 197H TSP

+3.39 F/L 05/94 RF0 C/L Special Int VOL 0.18 19TH TSP

+3.87 19TH TSP 26 85 05/94 RF0 Bobbin ADI 2.44 15TH TSP

+8.54 F/L 05/94 RF0 C/L Special Int VOL 0.15 15TH TSP

+8.54 15fH TSP 26 88 05/94 RF0 Bobbin ADI 5.67 3AVB

+6.00 F/L 05/94 RF0 U-bend VOL 0.67 3AVB

+6.19 4AVB 05/94 RF0 U Bend VOL 0.87 STH TSP

+12.78 4AVB 05/94 RF0 U-Bend VOL 0.88 BTH TSP

+10.69 4AVB 05/94 RF0 U-Bend VOL 0.93 81H TSP

+15.34 4AVB 26 95 05/94 RF0 Bobbin ADI 6.11 11TH TEP

+25.89 F/L 05/94 RF0 C/L Special Int VOL 0.77 111H TSP

+25.93 11TH TSP

+

26 98 05/94 RF0 Bobbin DDI 10 0.79 6TH TSP

+11.69 F/L 26 99 05/94 RF0 Bobbin ODI 25 0.5817TH TSP

+1.36 F/L 05/94 RF0 C/L Special Int VOL 0.48177H TSP

+1.25 17TH TSP 27 11 05/94 RF0 Bobbin ODI 17 1.96 13TH TSP

+13.91 F/L 27 12 05/94 RF0 Bobbin DDI 9

1.38 1BTH TSP

+11.03 F/L 27 27 05/94 RF0 Bobbin ADI 1.11 10TH TSP

+12.59 F/L 27 39 05/94 RF0 Bobbin ND1 0.76 91H TSP

-1.69 F/L 05/94 RF0 C/L Spectat Int VOL 0.31 9TH TSP 2,10 9TH TSP 27 43 05/94 RF0 Bobbin 001 13 0.73 13TH TSP

-7.02 F/L 27 49 05/94 RF0 Bobbin 001 10 2.25 11TH TSP

+26.79 F/L 27 56 05/94 RF0 Bobbin NQ) 1.38 8TH TSP

+1.54 F/L 27 67 05/94 RF0 Bobbin DDI 1

1.22 131H TSP

+14.04 F/L 27 94 05/94 RF0 Bobbin ODI 13 1.24 177H TSP

+11.67 F/L 05/94 RF0 H/L Tubesheet Vol 3.98 TTS-HL

+0.81 TTS HL 27 97 05/94 RF0 Bobbin ADI 7.85 2ND TSo

+8.90 F/L 05/94 RF0 Bobbin 0D1 7

1.12 13fH TSP

+39.92 F/L 05/94 RF0 Bobbin 00!

8 1.16 13TH TSP

+38.13 F/L 05/94 RTO Bobbin ODI 19 0.92 12TH TSP

+28.54 F/L 05/94 RF0 Bobbin 001 24 1.35 12TH TSP

+10.19 F/L 05/94 RF0 H/L Special Int VOL 0.84 2ND TSP

+9.42 2ND TSP 27 104 05/94 RF0 Bobbin NQ1 0.58 1AVB

+3.29 F/L 05/94 RTO U-Bend VOL 0.72 1AVB

+3.48 4AVB 27 105 05/94 RF0 Bobbin 001 4

2.30 BTH TSP

-1.12 F/L 05/94 RF0 H/L Special Int VOL 0.72 BTH TSP

-2.46 BTH TSP 05/94 RF0 H/L Spectat Int VOL 1.45 BTH TSP 1.30 8TH TSP 1

27 106 05/94 RF0 Bobbin No!

0.51 6TH TSP

+37.29 F/L 05/94 RF0 Bobbin No!

0.58 6TH TSP

+41.67 F/L 05/94 RF0 H/L Speclat Int VOL 0.21 ?TH TSP

-6.38 71H TSP 05/94 RF0 H/L SDecial Int VOL 0.28 7TH TSP

-1.42 7TH TSP 28 12 05/94 RF0 Bobbin 001 18 0.63 10TH TSP

+26.20 F/L 28 16 05/94 RF0 Bobbin DDI 23 1.10 12TH TSP

+12.75 F/L 28 18 05/94 RF0 Bobbin ADI 5.91 11TH TSP

+25.83 F/L 05/94 RF0 C/L Special Int VOL 1.1711TH TSP

+26.43 11TH TSP 28 19 05/94 RF0 Bobbin No!

0.51 9TH TSP

+0.82 F/L 05/94 RF0 Bobbin DDI 20 1.09 87H TSP

-4.20 F/L 05/94 RF0 C/L Special Int VOL 0.59 91H TSP

-3.02 9TH TSP 05/94 RF0 C/L Special Int VOL 0.59 9TH TSP

-3.62 9TH TSP 05/94 RF0 C/L Special Int VOL 0.60 9TH TSP

-0.89 97H TSP 05/94 RIO C/L Spectat Int VOL 0.62 91H TSP

-1.59 97H TSP

)

..........ee......e*********

BWNS TUBAN 11 (Version 2.0) 06/17/1994 06:39:09 l

ee**************************

Catawba Nuclear Station Unit Two eee..................*******

S/G 0 05/94 RF0 i

..ee************************

Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U Bend Page 20 of 32 S/G 0 - ATTACHMENT #4 INDICATIONS OF IMPERFECTIONS ROW COL DUTAGE TEST TYPE IND %TW VOLTS LOCATION EXTENT 1 05/94 RF0 C/L Special Int VOL 0.66 91H TSP

-2.23 97H TSP 05/94 RF0 C/L Special Int VOL 0.69 97H TSP

+0.42 91H TSP 05/94 RF0 C/L Special Int VOL 0.96 9TH TSP 0.29 91H TSP 05/94 RF0 C/L Specist Int VOL 0.99 91H TSP

+1.02 9TH TSP 28 25 05/94 RF0 Bobbin 001 10 0.B4 9FH TSP

-8.32 F/L 28 27 05/94 RF0 Bobbin ODI 28 0.53 15fH TSP

-9.57 F/L i

28 32 05/94 RF0 Bobbin 001 27 0.49 16TH TSP

-9.40 F/L 28 33 05/94 RF0 Bobbin NQI 0.52 12TH TSP

+5.21 F/L 05/94 RF0 Bobbin 001 30 1.04 19TH TSP

+2.68 F/L 05/94 RF0 C/L Special Int VOL 0.45 12TH TSP

+5.29 12TH TSP i

28 40 05/94 RF0 Bobbin NQI 1.14 81H TSP

+1.23 F/L 28 41 05/94 RF0 Bobbin 001 9

0.79 1ST TSP

+10.80 F/L 28 63 05/94 RF0 Bobbin DDI 14 0.58 10TH TSP

+40.65 F/L 28 64 05/94 RF0 Bobbin 001 9

1.33 16TH TSP

+16.47 F/L 28 65 05/94 RF0 Bobbin 001 8

0.72 14TH TSP

+13.57 F/L 05/94 RF0 C/L Special Int VOL 0.45 13TH TSP

-4.41 13fH TSP 28 71 05/94 RF0 Bobbin NQ1 1.20 2AVB

+0.53 F/L 05/94 RF0 U Bend VOL 0.47 2AVB

+0.54 3AVB 28 72 05/94 RF0 Bobbin NQI 0.31 16TH TSP

+10.49 F/L 05/94 RF0 C/L Special Int VOL 0.38 16TH TSP

+10.86 16TH TSP 28 73 05/94 RF0 Bobbin NCI 0.79 3RD TSP

+3.54 F/L 05/94 RF0 H/L Special Int VOL 0.51 3RD TSP

+3.62 3RD TSP 28 81 05/94 RF0 Bobbin ODI 37 0.44 10TH TSP

+40.73 F/L 05/94 RF0 C/L Special Int VOL 0.41 97H TSP

-2.37 9TH TSP 05/94 RF0 C/L Special Int VOL 0.58 9TH TSP

-1.18 97H TSP 28 83 05/94 RF0 Bobbin Nol 0.52 7TH TSP

+40.42 F/l 05/94 RF0 Bobbin 001 10 1.10 10TH TSP

+36.82 F/L 28 94 05/94 RF0 Bobbin No!

2.29 2ND TSP

+22.53 F/L 05/94 RF0 Bobbin Nol 2.54 171H TSP

+1.98 F/L 05/94 RF0 H/L Spectat Int VOL 1.05 2ND TSP

+22.59 2ND TSP 05/94 RF0 C/L Special Int VOL 0.55 171H TSP

+1.68 17TH TSP 28 102 05/94 RF0 Bobbin ODI 28 0.45 71H TSP

+38.21 F/L 28 104 05/94 RF0 Bobbin Not 0.94 11TH TSP

+24.64 F/L 05/94 RF0 C/L Special Int VOL 0.51 11TH TSP

+29.05 10TH TSP 05/94 RF0 C/L Speclat Int VOL 0.63 11TH TSP

+24.35 10TH TSP 28 106 05/94 RF0 Bobbin N01 0.59 12TH TSP

+10.50 F/L 05/94 RTO C/L Spectat Int VOL 0.64 12TH TSP

+10.50 12TH TSP 29 11 05/94 RF0 Bobbin 001 13 0.68 9TH TSP

-2,43 F/L j

05/94 RF0 Bobbin ODI 18 0.75 9TH TSP 4.39 F/L 29 14 05/94 RF0 Bobbin ODI 1

1.16 BTH TSP

-1 0. 75 F/L 29 17 05/94 RF0 Bobbin ODI B

2.02 10TH TSP

+23.70 F/L i

05/94 RF0 C/L Special int VOL 0.16 10TH TSP

+17.59 10TH TSP 05/94 RF0 C/L Special Int VOL 0.77 10TH TSP

+2?.25 10TH TSP l

29 33 05/94 RF0 Bobbin 001 12 1.6B 10TH TSP

+1.14 F/L 29 36 05/94 RF0 Bobbin DDI 4

0.88 97H TSP

-2.42 F/L 05/94 RF0 Bobbin 001 9

1.03 STH TSP

-4.13 F/L 05/94 RF0 Bobbin 001 22 0.92 STH TSP

+6.05 F/L 29 37 05/94 RF0 Bobbin No!

0.83 3RD TSP

+13.25 F/L 05/94 RF0 Bobbin 001 2

0.67 9TH TSP 9.17 F/L 05/94 RF0 Bobbin 001 14 2.16 101H TSP

+23.34 F/L C5/94 RF0 H/L Special Int VOL 0.46 3RD TSP

+12.98 3RD TSP 29 39 03/94 RF0 Bobbin 001 7

0.61 7TH TSP

+39.21 F/L 05/94 RF0 Bobbin ODI 13 0.58 7TH TSP

+35.72 F/L 05/94 Pro Bobbin 001 31 0.36 10TH TSP

+42.45 F/L 29 42 05/94 RF0 Bobbin No!

0.56 BTH TSP

+0.67 F/L 05/94 RF0 Bobbin NQI 0.73 91H TSP

+1.63 F/L 29 45 05/94 RF0 Bobbin 001 5

0.56 15TH TS/

2.27 F/L 29 50 05/94 RF0 Bobbin 001 21 0.78 2ND TSP

+13.42 F/L 29 51 05/94 RF0 Bobbin 001 6

1.70 7TH TSP

+15.93 F/L 05/94 RF0 Bobbin DDI 8

1.10 7TH TSP

+17.86 F/L 05/94 RF0 Bobbin ODI 21 0.39 7TH TSP

+14.09 F/L 29 56 05/94 RF0 Bobbin 001 8

0.48 131H TSP 2.78 F/L Po 59 05/94 RF0 Bobbin ADI 4.15 18TH TSP

+12.07 to +13.94 F/L j

C5/94 RfD C/L Special Int VOL 0.3517TH TSP

-4.53 17TH TSP 05/94 RF0 C/L Special Int VOL 1.02171H TSP

-5.80 171H TSP 05/94 RF0 C/L Special Int VOL 1.23 171H TSP

-2.58 17TH TSP

]

1 i

i I

DwNS TUBAN II (Version 2.0) 06/17/1994 06:39:09 eeeeeeeee.eeeeeeeeeeeeeeee.e Catawba Nuclear Station - Unit Two eeeeeeee..................**

S/G D ee**************************

05/94 RF0 Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U Bend

.ee.ee..................****

Page 21 of 32 i

S/G D - ATTACHMENT #4 INDICA 110NS OF IMPERFECTIONS RDW COL DUTAGE TEST TYPE IND %TW VOLTS LOCAfl0N EXTENT 1 05/94 RF0 C/L Special Int VOL 1.46 177H ISP

-4.90 171H TSP 05/94 RF0 C/L Special Int VOL 1.54 17TH TSP 3.84 171H TSP i

29 63 05/94 RF0 Bobbin No!

1.07 TTS CL

+1.97 F/L 05/94 RF0 Bobbin ADI 9.63 14TH ISP

+11.61 F/L 05/94 RF0 C/L Spectat Int VOL 0.46 Tis-CL

+2.03 TTS-HL 05/94 RF0 C/L Special Int VOL 0.83 14TH T$P

+11.20 14TH TSP 29 66 05/94 Rr0 Bobbin 001 1

1.50 14TH TSP

+6.34 F/L 05/94 RF0 Bobbin 001 4

2.13 15fH TSP

+7.12 F/L 05/94 RF0 Bobbin col 11 0.50 10TH TSP

+23.42 F/L 30 14 05/94 RF0 Bobbin ODI 1

1.37101H TSP

+33.77 F/L 30 15 05/94 RF0 Bobbin No!

0.69 STH TSP

+0.77 F/L 30 20 05/94 RF0 Bobbin 001 16 4.66 1ST ISP

+23.54 F/L 30 22 05/94 RF0 Bobbin ODI 26 0.59 81H ISP

-12.21 F/L 30 29 05/94 RF0 Bobbin 001 11 0.56 10TH TSP

+39.01 F/L 30 31 05/94 RF0 Bobbin No!

0.46 11TH 1SP

+22.95 F/L 05/94 RF0 C/L Special Int VOL 0.26 111H TSP + 25. 73 111H TSP 05/94 RF0 C/L Special Int VOL 0.62 11TH ISP

+23.76 11TH TSP 30 33 05/94 RF0 Bobbin DDI 7

1.82 10TH TSP

+29.02 F/L 30 36 05/94 RF0 Bobbin DDI 27 0.69 2ND TSP

+25.69 F/L 30 37 05/94 RF0 Bobbin 001 36 0.27 91H ISP

+0.06 F/L 05/94 RF0 C/L Speciat Int VOL 0.27 9TH ISP

+0.02 97H TSP 30 38 05/94 RF0 Bobbin 001 7

'.63 71H TSP

+ 32. 73 F/L 30 39 05/94 RF0 Bobbin 001 1

1.00 11TH TSP

+9.69 F/L 30 4' 05/94 RF0 Bobbin 001 35 0.33 2ND TSP

+22.94 F/L 05/94 RF0 H/L Special Int VOL 0.24 3RD TSP

-12.96 3RD TSP 30 41 05/94 RF0 Bobbin 001 19 2.9714TH TSP

+1.50 F/L 05/94 RF0 C/L Spectat Int Vol 0.44 14TH TSP

+0.68 14TH TSP 05/94 RF0 C/L Special Int VOL 1.15 14TH ISP

+1.74 14TH ISP 30 46 05/94 RF0 Bobbin 001 1

0.93 10TH TSP

+31.67 F/L 05/94 RF0 Bobbin 001 5

0.31 10iH TSP

+36.27 F/L 05/94 RF0 Bobbin 001 14 0.51 10TH TSP

+36.01 F/L 30 47 05/94 RF0 Bobbin Nol 0.79 41H TSP

+18.81 F/L 05/94 RF0 H/L Special Int VOL 0.54 4TH TSP

+19.70 4TH TSP 30 50 05/94 RF0 Bobbin 001 25 0.21 81H ISP

-0.15 F/L 30 54 05/94 RF0 Bobbin 001 17 1.19 131H TSP

+15.55 F/L 30 55 05/94 RF0 Bobbin ODI 6

3.48 14TH TSP

-1.20 F/L 05/94 RF0 C/L Special Int VOL 0.53 14TH TSP

-2. 73 14TH TSP 30 59 05/94 RF0 Bobbin 001 16 v.99 71H ISP

+30.14 F/L 05/94 RF0 Bobbin 001 16 1.23 77H TSP

+32.82 F/L 05/94 RTO Bobbin 001 30 1.01 97H ISP

-0.58 F/L 30 77 05/94 RF0 Bobbin 001 10 1.49 13TH ISP

+16.24 F/L 05/94 RF0 Bobbin 001 21 1.4817TH TSP

+8,99 F/L 30 79 05/94 RF0 Dobbin NO!

1.84 16TH TSP

+1.10 F/L 05/94 RF0 C/L Special Int VOL 1.13 16TH TCP

+1.00 16TH TSP 30 83 05/94 RF0 Bobbin N01 0.36 10TH TSP

+37.28 F/L 30 86 05/94 RF0 Bobbin 001 7

0.62 161H ISP

+11.24 F/L 30 99 05/94 RF0 Bobbin No!

0.48 91H 1SP

+1.11 F/L 05/94 RF0 C/L Special Int VOL 1.14 97H ISP

+1.21 97H TSP 30 105 05/94 RF0 Bobbin ADI 5.84 3RD ISP

-6.38 F/L i

05/94 RF0 H/L Spectat Int VOL 1.83 3RD iSP

-6.72 3RD TSP 31 13 05/94 RF0 Bobbin N01 0.99 BTH TSP

+0.80 F/L 31 15 05/94 RF0 Bobbin 001 11 1.86 TTS CL

+6.25 F/L 05/94 RF0 C/L Special Int VOL 1.09 TTS CL

+5.46 TIS-HL i

31 16 05/94 RF0 Bobbin 001 12 0.82 10TH TSP

+43.65 F/L 05/94 RF0 Bobbin 001 20 0.78 10TH TSP

+43.24 F/L 05/94 RF0 Bobbin 001 26 0.35 10TH TSP

+36.65 F/L 05/94 RF0 C/L Special Int VOL 0.32 91H TSP 7.28 9TH TSP 05/94 RF0 C/L Special Int VOL 0.37 97H 1SP

-4.93 97H 15P 05/94 RF0 C/L Special Int VOL 0.79 9TH TSP

-6.95 91H TSP 05/94 RF0 C/L Special Int VOL Oc94 91H TSP

-8.13 91H TSP 05/94 RF0 C/L Special int VOL 0.53 9TH 1SP

-4.50 to

-3.56 97H 1$P 05/94 RF0 C/L Spectat Int VOL

~0.65 91H TSP

-1.61 to

-0.47 91H TSP r

05/94 RF0 C/L Special Int VOL 1.35 9TH TSP 2.63 to

-2,17 97H TSP 31 22 05/94 RF0 Bobbin 001 7

0.75 14TH TSP

+6.26 F/L 05/94 RF0 C/L Special Int VOL 0.20 14TH ISP

+5.87 14TH TSP 31 23 05/94 RF0 Bobbin ADI 3.16 131H TSP

+26.51 F/L l

i t

eeeeeeee**ee.............***

BWNS TUBAN 11 (Version 2.0) 06/17/1994 06:39:09 ee**************************

Catawba Nuclear Station Unit Two i

eeeeee.....................

S/G D eeeeee.....................

05/94 RF0 eeeee**..................***

Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U Bend Page 22 of 32 S/G D - ATTACHMENT #4 INDICATIONS OF IMPERFECTIONS RDW COL DUTAGE TEST TYPE IND %TW VOLTS LOCATION EXTENT!

05/94 RF0 Bobbin ODI 14 2.56 13fH TSP

+8.42 F/L 31 24 05/94 RF0 Bobbin DDI 26 1.24 151H TSP

+10.76 F/L 31 25 05/94 RF0 Bobbin 001 5

2.65 171H TSP

+7.99 F/L 31 37 05/94 RF0 Bobbin 001 5

1.77 7TH TSP

+29.99 F/L 05/94 RF0 Bobbin 001 6

1.45 12TH TSP

+31.34 F/L 31 38 05/94 RF0 Bobbin 001 33 1.05 19TH TSP

+2.16 F/L 31 39 05/94 RF0 Bobbin 001 16 1.35 11TH TSP

+12.34 F/L 05/94 RF0 C/L Spectat Int VOL 1.00 11TH TSP

+12.21 11TH TSP 31 40 05/94 RF0 Bobbin 001 12 0.86 12TH TSP

+34.35 F/L 31 41 05/94 RF0 Bobbin No!

0.36 4TH TSP

+32.14 F/L 31 49 05/94 RF0 Bobbin 001 6

1.58 16TH TSP

+7.73 F/L 31 59 05/94 RF0 Bobbin 001 15 0.86 7TH TSP

+32.23 F/L 05/94 RF0 Bobbin 001 21 0.67 10TH TSP

+38.51 F/L 05/94 RF0 Bobbin 001 21 0.99 10TH TSP

+40.01 F/L 31 63 05/94 RF0 Bobbin NQ1 0.60 12TH TSP

+19.23 F/L 05/94 RF0 Bobbin No!

1.01 12TH TSP

+27.64 F/L 05/94 RF0 Bobbin NO!

1.24 12TH TSP

+22.59 F/L 05/94 RF0 Bobbin NO!

1.54 12TH TSP

+24.69 F/L 05/94 RF0 C/L Special Int VOL 0.54 12TH TSP

+19.53 12TH TSP 05/94 RF0 C/L Special Int VOL 1.21 12TH TSP

+23.18 12TH TSP 05/94 RF0 C/L Special Int VOL 1.39 12TH TSP

+25.20 12TH TSP 05/94 RF0 C/L Spectat Int VOL 1.96 12TH TSP

+29.07 121H TSP 31 65 05/94 RF0 Bobbin h0!

0.63 9TH TSP 4.08 F/L 05/94 RF0 Bobbin ODI 3

0.96 18TH TSP

+10.50 F/L 31 67 05/94 RF0 Bobbin ODI 4

1.12 3RD TS'

+17.94 F/L 05/94 RF0 Bobbin 001 17 0.71 3RD TSP

-3.07 F/L 05/94 RF0 Bobbin 001 14 1.41 13TH TSP

+38.39 F/L 31 68 05/94 RF0 Bobbin 001 24 1.85 TTH TSP

+22.64 F/L 31 76 05/94 RF0 Bobbin No!

0.49 9TH TSP

-2.15 F/L 31 77 05/94 RF0 Bobbin No!

0.78 10TH TSP

-3.12 F/L 05/94 RF0 C/L Special Int VOL 1.08 10TH TSP

-2.99 10TH TSP 31 78 05/94 RF0 Bobbin NQI 1.02 12TH TSP

-3.79 F/L 05/94 RF0 C/L Special Int VOL 0.69 12TH TSP

-3.88 12TH TSP 31 82 05/94 RF0 Bobbin NQ1 0.51 71H TSP

+24.26 F/L 05/94 RF0 Bobbin DDI 1

0.86 7TH TSP

+25.32 F/L 05/94 RF0 H/L Special Int VOL 0.84 71H TSP

+23.83 BTH TSP 05/94 RF0 H/L Special Int VOL 1.57 7TH TSP

+25.02 BTH TSP 31 86 05/94 RF0 Bobbin kol 1.42 1AvB

+ 7. 4 2 F/L 05/94 RF0 U Bend VOL 0.51 1AVB

+6.66 3AVB 05/94 RF0 Bobbin ADI 2.79 15TH TSP

+11.81 F/L 05/94 RF0 Bobbin ADI 3.20 13TH TSP

+22.13 F/L 05/94 RF0 Bobbin 001 17 0.79 11TH TSP

+10.47 F/L 05/94 RF0 C/L Spectat Int VOL 0,48 1STH TSP

+12.88 15TH TSP 05/94 RF0 C/L Special Int VOL 0.51 11TH TSP

+10.92 11TH TSP 05/94 RFC C/L Spectet Int VOL 0.71 13TH TSP

+22.60 13TH TSP 31 87 05/94 RF0 Bobbin 001 4

3.59 15TH TLP

-8.08 F/L 05/94 RF0 C/L Special Int VOL 1.22 15YH TSP

-9.36 15fH TSP 31 92 05/94 RF0 Bobbin 001 10 1.45 15TH TSP

+11.55 F/L 31 104 05/94 RF0 Bobbin NQI 0.47 9TH TSP

+0.60 F/L 05/94 RF0 C/L Special Int VOL 1.20 91H TSP

+0.74 9TH TSP 32 12 05/94 RF0 Bobbin 001 8

0.83 10TH TSP

+40.80 F/L 05/94 RF0 C/L Special Int VOL 0.18 9TH TSP

-3.16 91H TSP 05/94 RF0 C/L Special Int VOL 0.37 9TH T$P 5.19 9TH TSP 05/94 RF0 C/L Special Int VOL 0.39 9TH TSP

-6.44 91H TSP 05/94 RF0 C/L Spectat Int VOL 0.97 9TH TSP

-4.03 9TH TSP 32 13 05/94 RF0 Bobbin NQI 0.64 BTH TSP

+1.64 F/L 05/94 RF0 Bobbin No!

0.77 8TH TSP

+2.14 F/L 32 29 05/94 RF0 Bobbin NQ1 0.92 3RD TSP

+15.56 F/L 05/94 RF0 Bobbin DDI 8

1.27 3RD TSP

+23.55 F/L i

05/94 RF0 Bobbin 001 17 0.82 3RD TSP

+24.67 F/L 05/94 RfD Bobbin 001 28 0.99 3RD TSP

+26.34 F/L 05/94 RF0 H/L Speclat Int VOL 0.41 3RD TSP

+14.86 3RD TSP i

32 32 05/94 RF0 Bobbin ADI 2.94 1AVB

+15.79 F/L 05/94 RF0 Bobbin ADI 5.59 2AVB

+1.73 F/L 32 37 05/94 RF0 Bobbin ADI 3.85 6TH TSP

+21.23 F/L 05/94 RF0 H/L Special Int VOL 0.83 6TH TSP

+21.03 6TH TSP l

w

......ee.*******************

BWNS TUBAN 11 (Version 2.0) 06/17/1994 06:39:09 Catawba Nuclear Station - Unit Two S/G D eeeeeeee+.******************

05/94 RF0 Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U-Bend Page 23 of 32 S/G D - ATTACHMENT #4 INDICATIONS OF IMPERFECTIONS RDW COL DUTACE TEST TYPE IND %TW VOLTS LOCATION EXTENT 1 32 41 05/94 RF0 Bobbin 001 22 0.71 9TH TSP

-4.66 F/L 32 46 05/94 RF0 Bobbin DDI 10 0.65 1BTH TSP

-4.02 F/L 32 48 05/94 RF0 Bobbin NCI 0.64 13fH TSP

+23.20 F/L 05/94 RFO C/L Special Int VOL 0.64 12fH TSP

-19.52 12TH TSP 32 59 05/94 RF0 Bobbin 001 3

0.88 77H TSP

+29.35 F/L 32 62 05/94 RF0 Bobbin 001 1

0.63 15TH TSP

-3.84 F/L 05/94 RF0 Bobbin ODI 11 1.14 16TH TSP

+14.99 F/L 05/94 RF0 Bobbin 001 20 0.83 11TH TSP

+33.12 F/L 32 64 05/94 RF0 Bobbin NQI 0.36 11TH TSP

-9.87 F/L 05/94 RTO C/L Special Int VOL 0.17 11TH TSP

-10.91 11TH TSP 32 65 05/94 RF0 Bobbin 001 4

3.27 7TH TSP

+4.17 F/L 05/94 RF0 Bobbin 001 12 2.94 13TH TSP

+25.81 F/L 32 66 05/94 RF0 Bobbin ODI 21 0.71 10TH TSP

+34.98 F/L 32 70 05/94 RF0 Bobbin 001 3

0.53 6TH TSP

+26.17 F/L 32 71 05/94 RF0 Bobbin 001 27 0.25 7TH TSP

+36.13 F/L 03/94 RF0 H/L Special Int VOL 1.31 7TH TSP

+37.09 8TH TSP 32 75 05/94 RF0 Bobbin 001 11 0.73 10TH TSP

+36.08 F/L 32 76 05/94 RF0 Bobbin ODI 16 4.87 BTH TSP

+16.73 F/L 32 82 05/94 RF0 Bobbin 001 32 0.38 77H TSP

+35.14 F/L 05/94 RF0 Bobbin 001 3

1.91 10TH TSP

+22.61 F/L 05/94 RF0 Bobbin 001 4

1.25 10TH TSP

+9.66 F/L 05/94 RF0 C/L Special Int VOL 1.58 10TH TSP

+9.21 10TH TSP 05/94 RF0 C/L Special Int VOL 1.72 10TH TSP

+23.22 10TH TSP 05/94 RFO C/L Special Int VOL 2.18 10TH TSP

+10.34 10TH TSP 05/94 RF0 C/L Special Int VOL 2.50 10TH TSP

+24.39 10TH TSP 32 86 05/94 RF0 Bobbin 001 15 3.75 3AVB 12.09 F/L 05/94 RF0 U Bend VOL 0.47 3AVB 11.18 9TH TSP 05/94 RF0 Bobbin 001 8

4.89 12TH TSP

+28.95 F/L 05/94 RF0 Bobbin DDI 10 0.56 13fH TSP

+25.16 F/L 05/94 RF0 C/L Special Int VOL 0.26 13fH TSI

+25.89 13fH TSP 05/94 RF0 C/L Special Int VOL 2.43 12TH TSP

+30.41 12TH TSP 32 88 05/94 RFO Bobbin 001 11 0.74 7TH TSP

+35. 75 F/L 32 90 05/94 RF0 Bobbin 001 1

1.23 10TH TSP

+13.65 F/L 32 92 05/94 RF0 Bobbin 001 9

1.08 13fH TSP

+21.26 F/L 05/94 RF0 C/L Special Int VOL 0.34 13fH TSP

+20.70 13TH TSP 05/94 RF0 C/L Special Int Vol 0.45 13TH TSP

+24.58 131H TSP 05/94 RF0 C/L Special Int VOL 0.50 13TH TSP

+21.47 13TH TSP

)

32 93 05/94 RF0 Bobbin 001 7

0.63 4TH TSP

-6.66 F/L 32 101 05/94 RF0 Bobbin ADI 6.30 4AVB

-10.30 F/L 05/94 RF0 U-Bend VOL 0.33 4AVB

-7.30 9tH TSP 05/94 RF0 U Bend VOL 0.54 4AVB

-10.04 9TH TSP 05/94 RF0 Bobbin 001 16 1.84 17TH TSP

+0.96 F/L 32 103 05/94 RF0 Bobbin ODI 18 1.38 10TH TSP

+40.70 F/L 33 13 05/94 RF0 Bobbin WAR 16 0.73 3AVB

+0.00 F/L 05/94 RF0 Bobbin WAR 26 1.61 2AVB

+0.00 F/L I

33 16 05/94 RF0 Bobbin ODI 15 0.39 7TH TSP

+0.35 F/L l

05/94 RF0 H/L Special Int VOL 0.49 7TH TSP

+0.32 7TH TSP i

33 17 05/94 RF0 Bobbin ODI 23 0.53 10TH TSP

+40.13 F/L 33 26 05/94 RF0 Bobbin ADI 3.14 11TH TSP

-5.04 F/L 05/94 RF0 C/L Special Int VOL 0.73 11TH TSP

-5.31 11TH TSP 33 28 05/94 RF0 Bobbin 001 14 0.44 10TH TSP

+34.60 F/L 33 35 05/94 RF0 Bobbin 001 29 0.63 71H TSP

+2 7.15 F/L 33 40 05/94 RF0 Bobbin No!

0.66 10TH TSP

+15.44 F/L 05/94 RFC C/L Special Int V0L 0.21 10TH TSP

+13.80 10TH TSP 33 41 05/94 RF0 Bobbin ADI 2.35 STH TSP

+6.95 F/L 05/94 RF0 Bobbin ADI 3.96 3RD TSP

+26.27 F/L 05/94 RFO H/L Special Int VOL 0.74 3RD TSP

+26.08 3RD TSP 05/94 RF0 H/L Special Int VOL 0.77 STH TSP

+7.67 STH TSP 33 46 05/94 RF0 Bobbin NOI 0.44 10TH TSP

+15.78 F/L 05/94 RF0 C/L Special Int VOL 0.50 10TH TSP

+13.71 10TH TSP 33 48 05/94 RF0 Bobbin 001 19 2.91 10TH TSP

+ 7.12 F/L 05/94 RF0 C/L Special Int VOL 0.52 10TH TSP

+3.48 10iH TSP 05/94 RF0 C/L Special Int VOL 0.55 10TH TSP

+2.84 10TH TSP 05/94 RF0 C/L Special Int VOL 0.5710TH TSP

+1.07 10TH TSP 05/94 RF0 C/L Special Int VOL 0.61 10TH TSP

+1.49 10TH TSP 05/94 RFC C/L Special Int VOL 0.65 10TH TSP

+2.16 10TH TSP

BwNS TUBAN 11 (Version 2.0) 06/17/1994 06:39:09 Catawba Nuclear Station - Unit Two eeeeee......**...**********

S/G 0 05/94 RF0 Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U Bend Page 24 of 32

)

S/G 0 - ATTACHMENT #4 INDICATIONS OF !MPERFfCTIONS ROW COL DUTAGE TEST TYPE IND %TW VOLTS LOCATION EXTENT 1 05/94 RF0 C/L Special Int VOL 0.88 10TH TSP

+0.68 10TH TSP 05/94 RF0 C/L Special Int VOL 1.12 10TH TSP

+6.50 10TH TSP 05/94 RF0 C/L Special Int VOL 1.14 10TH TSP

-1.05 10TH TSP 05/94 RF0 C/L Special Int VOL 1.21 10TH TSP

-1.96 10TH TSP 33 55 05/94 RF0 Bobbin 001 16 0.65 7TH TSP

+20.70 F/L 33 62 05/94 RF0 Bobbin 001 2

5.20 4AVB

-5.41 F/L 33 63 05/94 RF0 Bobbin ADI 1.49 10TH TSP

+41.87 F/L 05/94 RF0 Bobbin AD1 3.42 10TH TSP

+36.96 F/L 05/94 RF0 Bobbin 001 7

0.73 8TH TSP 8.13 F/L 05/94 RF0 Bobbin 001 13 0.86 9TH TSP

-5.45 F/L 05/94 RF0 C/L Special Int VOL 0.51 9TH TSP

-5.13 9TH TSP 05/94 RF0 C/L Special Int VOL 1.40 9TH TSP

-4.02 9TH TSP 05/94 RF0 C/L Special Int VOL 1.71 9TH TSP

-10.10 9TH TSP 05/94 RF0 C/L Special Int VOL 2.95 97H TSP

-8.82 9TH TSP 33 64 05/94 RF0 Bobbin 001 9

0.90 10TH TSP

+25.09 F/L 33 66 05/94 RF0 Bobbin ODI 9

2.36 12TH TSP 6.97 F/L 33 75 05/94 RF0 Bobbin 001 27 0.54 14TH TSP

+11.78 F/L 05/94 RF0 C/L Special Int VOL 0.34 14TH TSP

+12.32 14TH TSP 33 77 05/94 RF0 Bobbin 001 7

1.05 1ST TSP

+11.13 F/L 33 85 05/94 RF0 Bobbin 001 14 0.40 71H TSP

+38.20 F/L 33 86 05/94 RF0 Bobbin ODI 13 0.96 15TH TSP

+11.92 F/L 33 88 05/94 RF0 Bobbin 001 15 1.45 15TH TSP

+8.03 F/L 05/94 RF0 C/L Special Int VOL 0.48 15TH TSP

+8.45 1STH TSP 33 103 05/94 RF0 Bobbin 001 36 0.39 7TH TSP

+36.95 F/L 34 16 05/94 RF0 Bobbin ADI 5.43 13TH TSP

+7,87 F/L 05/94 PF0 Bobbin ADI 5.73 12TH TSP

+27.33 F/L 05/94 RF0 Bobbin 001 22 0.75 16TH TSP

+2.64 F/L 05/94 RF0 C/L Special Int VOL 0.62 13TH TSP

+7.29 13TH TSP 05/94 RF0 C/L Special Int VOL 0.68 11TH TSP

-16.88 11TH ISP 34 17 05/94 RF0 Bobbin ODI 1

0.82 8TH TSP

-1.56 F/L 05/94 RF0 Bobbin 001 16 0.45 7TH TSP

+36.60 F/L 05/94 RF0 Bobbin 001 26 0.55 77H TSP

+38.74 F/L 34 32 05/94 RF0 Bobbin 001 2

1.01 10TH TSP

+32.54 F/L 05/94 RF0 C/L Speclat Int VOL 0.65 9TH TSP

-13.05 9TH TSP 34 36 05/94 RF0 Bobbin 001 12 0.57 11TH TSP

+25.74 F/L 34 38 05/94 RF0 Bobbin 001 15 0.50 9TH TSP

-0.62 F/L 34 56 05/94 RF0 Bobbin DDI 14 1.18 2ND TSP

+8.61 F/L 34 67 05/94 RF0 Bobbin ADI 1.40 12TH TSP

+39.02 F/L 05/94 RF0 C/L Spectat Int VOL 0.63 11TH TSP

-4.35 11TH TSP 34 69 05/94 RF0 Bobbin ADI 7.5810TH TSP

+26.55 F/L 05/94 RF0 Bobbin 001 32 0.82 7TH TSP

+35.97 F/L 05/94 RF0 C/L Special Int VOL 0.39 10TH TSP

+26.23 10TH TSP 34 75 05/94 RF0 Bobbin 001 1

1.68 TTH TSP

-8.10 F/L 05/94 RF0 Bobbin 001 21 1.30 8TH TSP

+15.32 F/L 34 79 05/94 RF0 Bobbin 001 6

1.45 3RD TSP

-2.03 F/L 05/94 RF0 Bobbin DDI 6

1.70 2ND T$P

+18.30 F/L 05/94 RF0 Bobbin DDI 9

1.01 17TH TSP

-9.90 F/L 05/94 RF0 H/L Special Int VOL 0.74 3RD TSP 1.29 3RD TSP 34 82 05/94 RTO Bobbin NQI 0.74 7TH TSP

+24.26 to +28.02 F/L 34 87 05/94 RF0 Bobbin 001 17 1.28 4TH ISP

+2.41 F/L 05/94 RF0 H/L Special Int VOL 0.42 4TH TSP

+3.40 STH TSP 05/94 RF0 H/L Special Int VOL 0.63 4TH TSP

+ 2. 64 STH TSP 05/94 RF0 H/L Special Int VOL 0.84 4TH TSP

+4.24 STH TSP 34 88 05/94 RF0 Bobbin 001 12 2.05 13TH TSP

+34.46 F/L 05/94 RF0 Bobbin 001 14 5.29 13TH TSP

+23.44 F/L 34 89 05/94 RF0 Bobbin 001 7

1.34 7TH TSP

+40.05 F/L 34 90 05/94 RF0 Bobbin ADI 2.95 13TH TSP

+4.23 F/L 05/94 RF0 C/L Special Int VOL 0.44 13TH TSP

+4.60 13TH TSP 34 94 05/94 RF0 Bobbin 001 1

6.86 81H TSP

+10.81 F/L 34 97 05/94 RF0 Bobbin 001 16 1.72 10TH TSP

+33. 73 F/L 34 98 05/94 RF0 Bobbin WAR 17 0.91 2AVB

+0.00 F/L j

34 99 05/94 RF0 Bobbin WAR 19 0.94 2AVB

+0.00 F/L

)

34 100 05/94 RF0 Bobbin WAR 13 1.54 3AVB

+0.00 F/L j

34 101 05/94 RF0 Bobbin 001 16 0.66 7TH TSP

+29.90 F/L 1

05/94 RF0 Bobbin 001 1

0.86 10TH TSP

+25.67 F/L 05/94 RF0 Bobbin 001 3

0.49 10TH TSP

+24.41 F/L

1 BWNS TUBAN 11 (Version 2.0) 06/17/1994 06:39:09 e............ ee........ee**

Catawba Nuclear Station - Unit Two l

S/G 0 05/94 RF0 eeeeeeeeeee, ee.************

Bobbin,C/L i;ecial Interest,H/L Special Interest,H/L Tubesheet,U-Bend Page 25 of 32

$/G D - ATTACHMENT #4 INDICATIONS OF IMPERFECTIONS ROW COL DUTACE TEST TYPE IND %TW VOLTS LOCATION EXTENT 1 35 14 05/94 RF0 Bobbin WAR 35 3.10 2AVB

+0.00 F/L 05/94 RF0 U-Bend VOL 0.65 2AVB

+0 00 2AVB 35 16 05/94 RF0 Bobbin 001 1

0.69 77H TSP

+38.71 F/L 05/94 RF0 Bobbin DDI 6

0.50 7Th TSP

-3!.62 F/L

?5 17 05/94 RF0 Bobbin 001 12 0.50 10TH 'iP

+21.09 F/L 05/94 RF0 C/L Special int VOL 0.84 10TH ISP

+21.11 10TH TSP 05/94 RF0 C/L Special Int VOL 1.28 10TH TSP

+20.02 10TH TSP 35 27 05/94 RF0 Bobbin ODI 7

1.36 2ND TSP

+18.94 F/L 35 32 05/94 RF0 Bobbin 001 2

1.65 6TH TSP

+30.80 F/L 35 41 05/94 RF0 Bobbin 001 16 0.71 6TH TSP

+18.32 T/L 35 52 05/94 RF0 Bobbin 001 3

0.46 12TH TSP

+19.69 F/L 35 66 05/94 RF0 Bobbin NOI 0.81 17TH TSP

-0.63 F/L 05/94 RF0 C/L Special Int VOL 2.39 17TH TSP

+0.00 17TH TSP 35 73 05/94 RF0 Bobbin 001 1

0.78 2ND TSP

+13.81 F/L 35 74 05/94 RF0 Bobbin ADI 3.54 3RD TSP

+11.53 F/L 05/94 RF0 H/L Special Int VOL 1.04 3RD TSP

+10.99 4TH TSP 05/94 RF0 H/L Special Int VOL 1.11 3RD TSP

+4.03 4TH TSP 35 75 05/94 RF0 Bobbin ADI 10.56 3AVB

-11.18 F/L 05/94 RFC Bobbin 001 7

3.61 4AVB

+7.01 F/L 05/94 RF0 U-Bend VOL 0.63 3AVB

-10.87 9TH TSP 05/94 RF0 U-Bend VOL 0.85 3AVB

-11.74 97H TSP 35 77 05/94 RF0 Bobbin ADI 10.47 STH TSP

+4.02 F/L 05/94 RF0 H/L Special Int VOL 0.16 STH TSP

+4.43 6TH TSP 35 79 05/94 RF0 Bobbin 001 27 0.48 7TH TSP

+34.05 F/L 35 93 05/94 RF0 Bobbin NOI 28.53 1AVB

+22.74 F/L 35 94 05/94 RF0 Bobbin ADI 5.78 3RD TSP

+22.57 F/L 05/94 RF0 Bobbin ADI 9.55 3RD TSP

+16.16 F/L 05/94 RFC H/L Special Int VOL 1,53 3RD TSP

+24.11 4TH TSP 05/94 RF0 H/L Special Int VOL 1.79 3RD TSP

+16.55 4TH TSP 35 101 05/94 RF0 Bobbin ADI 5.20 15TH TSP

+B.40 F/L 05/94 RF0 Bobbin 001 10 3.25 1ST TSP

+11.85 F/L 05/94 RF0 C/L Special int VOL 0.84 15TH TSP

+ 7. 88 151H TSP 36 16 05/94 RF0 Bobbin WAR 35 4.03 2AVB

+0.00 F/L 05/94 RF0 U-Bend VOL 1.38 2AVB

+0.00 2AVB 36 18 05/94 RF0 Bobbin 001 22 0.87 97H TSP

-2.95 F/L 05/94 RF0 C/L Special Int VOL 0.77 91H TSP

-2.49 9TH TSP 36 22 05/94 RF0 Bobbin Nol 1.15 14TH TSP

+8.02 F/L 05/94 RF0 Bobbin DDI 1

0.63 17TH TSP

+14.18 F/L 05/94 RF0 Bobbin ODI 4

0.61 16TH TSP

+11.42 F/L 05/94 RF0 Bobbin 001 4

0.87 177H TSP

+11.99 F/L 05/94 RF0 C/L Special Int VOL 0.64 17TH TSP

+14.34 17TH TSP 05/94 RF0 C/L Special Int VOL 0.78 17TH TSP

+12.24 17TH TSP 05/94 RF0 C/L Special Int VOL 0.82 16TH TSP

+11.49 16TH TSP 05/94 RF0 C/L Special Int VOL 0.87 14TH TSP

+8.62 14TH TSP 36 24 05/94 RF0 U Bend VOL 1.26 1AVB

+15.87 3AVB 05/94 RF0 Bobbin ADI 9.70 BTH TSP

+48.77 F/L 36 27 05/94 RF0 Bobbin 001 10 0.82 STH TSP

+18.83 F/L 36 31 05/94 RF0 Bobbin NOI 0.90 71H TSP

+2.15 F/L 05/94 RF0 H/L Special Int VOL 0.29 77H TSP

+2.17 7TH TSP 36 33 05/94 RF0 Bobbin 001 19 0.54 3RD TSP

+19.26 F/L 36 35 05/94 RF0 Bobbin 001 18 0.39 14TH TSP

+13.09 F/L 05/94 RF0 C/L Special Int VOL 0.68 14TH TSP

+11.77 14TH TSP 36 60 05/94 RF0 Bobbin ADI 2.94 11TH TSP

+24.29 F/L 1

36 62 05/94 RF0 Bobbin ADI 6.62 STH TSP

+20.23 F/L 05/94 RF0 H/L Special Int VOL 0.64 STH TSP

+23.58 6TH TSP 05/94 RF0 H/L Special Int VOL 1.10 STH TSP

+21.24 6TH TSP 36 63 05/94 RF0 Bobbin 001 5

1.90 3RD TSP

+34.30 F/L 05/94 RF0 Bobbin 001 15 1.58 2ND TSP

+24.65 F/L 05/94 RF0 Bobbin 001 9

0.60 131H TSP

+29.57 F/L 36 65 05/94 RF0 Bobbin DDI 31 1.64 3AVB

-0. 75 F/L 05/94 RF0 U-Bend VOL 0.32 3AVB

+ 0. 64 9TH TSP 36 66 05/94 RF0 Bobbin No!

0.42 1ST TSP

+11.98 F/L 05/94 RF0 Bobbin NQ1 0.45 1ST TSP

+10.79 F/L 36 75 05/94 RF0 Bobbin 001 12 1.41 fiH TSP

+33.44 F/L 05/94 RF0 Bobbin ODI 29 0.74 13fH TSP

+ 7. 77 F/L 36 76 05/94 RF0 Bobbin ADI 3.46 2ND TSP

+32.43 F/L

l eeeeee**********************

BWNS TUBAN !! (Version 2.0) 06/17/1994 06:39:09 l

eeeeeeeeeeee****************

Catawba Nuclear Station - Unit Two S/G D l

i

                                  • =**********

05/94 RF0 l

Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U-Bend l

Page 26 of 32

$/G 0 - ATTACHMENT #4 INDICATIONS OF IMPERFECTIONS i

ROW COL OUTAGE TEST TYPE IND %TW VOLTS LOCATION EXTENT 1 05/94 RF0 H/L Special Int VOL 1.42 3RD TSP 4.32 3RD TSP l

36 80 05/94 RF0 Bobbin 001 11 1.76 BiH TSP

-1.11 F/L l

05/94 RF0 H/L Special Int VOL 1.37 BTH TSP 0.94 8TH TSP 36 88 05/94 RF0 Bobbin 001 12 3.44 16TH TSP

+13.54 F/L i

36 91 05/94 RF0 Bobbin 001 4

0.49 9TH TSP

-0.84 F/L 05/94 RF0 Bobbin ODI 19 0.75 97H TSP

-1.14 F/L 05/94 RF0 C/L Special Int VOL 0.72 97H TSP

-0.99 9TH TSP l

05/94 RF0 C/L Special Int VOL 1.08 9TH TSP

-0.77 91H TSP l

36 93 05/94 RF0 Bobbin WAR 14 0.58 2AVB

+0.00 F/L i

l 05/94 RF0 Bobbin 001 5

0.88 1CTH TSP

+29.33 F/L 3e 94 05/94 RF0 Bobbin WAR 10 0.35 1AVB

+0.00 F/L l

05/94 RFO Bobbin WAR 17 0.71 2AVB

+0.00 F/L 36 95 05/94 RF0 Bobbin 001 3

2.25 2ND TSP

+17.64 F/L 05/94 RIO Bobbin 001 17 2.37 11TH TSP

+B.47 F/L 05/94 RF0 C/L Special Int VOL 0.45 11TH TSP

+8.36 11TN TSP 36 96 05/94 RIO Bobbin WAR 18 0.80 2AVB

+0.00 F/L 36 98 05/94 RF0 Bobbin 001 5

4.80 4TH TSP

+32.84 F/L 05/94 RF0 Bobbin ODI 6

3.25 4TH TSP

+36.69 F/L 05/94 RF0 Bobbin ODI B

3.57 4TH TSP

+24.85 F/L 05/94 RF0 Bobbin ODI 9

2.54 4TH TSP

+21.52 F/L 36 99 05/94 RF0 Bobbin ODI 7

1.82 3AVB 19.55 F/L 05/94 RF0 Bobbin ADI 3.01 14TH TSP

+5.17 F/L l

05/94 RF0 Bobbin ODI 13 1.92 121H TSP

-2.65 F/L l

05/94 RF0 C/L Speclat Int VOL 1.23 14TH TSP

+5.16 14TH TSP l

05/94 RF0 C/L Special Int VOL 1.80 12TH TSP

-3.12 12TH TSP 37 17 05/94 RF0 Bobbin WAR 16 0.63 2AVB

+0.00 F/L 05/94 RF0 Bobbin WAR 18 0.79 4AVB

+0.00 F/L 05/94 kFO Bobbin ADI 10.71 10TH TSP

+25.72 F/L 37 22 05/94 RF0 Bobbin ODI 11 1,81 121H TSP

+2.42 F/L 05/94 RF0 Bobbin 001 16 0.67 11TH TSP

+6.66 F/L j

05/94 RF0 C/t Speclat Int VOL 0.37 11TH TSP

+6.96 11TH TFP 05/94 RF0 C/L Special Int VOL 0.5612TH TSP

+2.47 12TH TSP 37 30 05/94 RF0 Bobbin 001 16 0.67 2ND TSP

+30.98 F/L i

37 35 05/94 RF0 Bobbin 001 6

0.81 7TH TFt

+18.58 F/L 05/94 RF0 Bobbin 001 2

0.69 14TH ifP

+2.60 F/L l

37 36 05/94 RF0 Bobbin 001 5

1.60 12TH !!?

+33.10 F/L t

37 37 05/94 RF0 Bobbin 001 12 1.00 10TH TSP

+36.58 F/L 05/94 RF0 Bobbin NQI 1.01 171H TSP

+1.32 to +10.19 F/L 05/94 RF0 C/L Special Int VOL 0.93 17TH TSP

+1.21 to +10.54 17TH TSP 37 43 05/94 RF0 Bobbin ODI 1

3.41 2ND TSP

+32.65 F/L 37 48 05/94 RF0 Bobbin 001 5 2.2217TH TSP

+1.25 F/L i

37 52 05/94 RF0 Bobbin ODI 33 0.4712TH TSP

+30.83 F/L l

37 61 05/94 RF0 Bobbin 001 35 1.49 13TH TSP

+18.67 F/L l

05/94 RF0 C/L Spectat Int VOL 0.63 13fP TSP

+21.19 13fH TSP l

37 63 05/94 RF0 Bobbin 001 3

5.22 91H TSP

-3.24 F/L 37 82 05/94 RF0 Bobbin ODI 4

1.06 7TH TSP

+21.65 F/L 37 83 05/94 RIO Bobbin NQ1 1.05 1ST TSP

+12.53 F/L 05/94 RF0 H/L Special Int VOL 0.80 1ST TSP

+12.94 2WD TSP 38 17 05/94 RF0 Bobbin WAR 26 1.10 4AVB 40.00 F/L 05/94 RF0 Bobbin WAR 35 2.16 2AVB

+0.00 F/L 05/94 RF0 U Bend VOL 0.37 2AVB

+0.00 2AVB 38 18 05/94 RF0 Bobbin WAR 20 0.71 4AVB

+0.00 F/L 05/94 RF0 Bobbin WAR 23 0.91 2AVB

+0.00 F/L 38 34 05/94 RF0 Bobbin ODI 16 0.71 111H TSP

+27.65 F/L 38 36 05/94 RF0 Bobbin N01 0.58 10TH TSP

+6.81 F/L 05/94 RIO C/L Special Int VOL 0.58 10TH TSP

+6.65 10TH TSP l

38 39 05/94 RF0 Bobbin ODI 12 0.54 97H TSP

-6.40 F/L 38 46 05/94 RIO Bobbin NQI 1.28 7TH TSP

+14.77 F/L 38 49 05/94 RF0 Bobbin 001 11 3.42 10TH TSP

+7.17 F/L P'

63 05/94 RF0 Bobbin No!

0.93 BTH TSP

+0.75 F/L 38 65 05/94 RF0 Bobbin 001 21 0.75 14TH TSP

+5.61 F/L 05/94 RIO C/L Speclat Int VOL 1.06 14TH TSP

+5.79 14TH TSP 38 70 05/94 RF0 Bobbin ADI 3.98 121H TSP

+3.66 F/L 05/94 RF0 C/L Spectat Int VOL 0.97 12TH TSP

+3.51 12TH TSP 05/94 RF0 C/L Special int VOL 1.34 12TH TSP

+2.36 12TH TSP 35 73 05/94 RTO Bobbin 001 11 3.30 6TH TSP

+31.B4 F/L l

l

BWNS TUBAN 11 (Version 2.0) 06/17/1994 06:39:09 ee**eeeee*******************

Catawba Nuclear Station - Unit Two eeeeee e*****..**,.

sfg g

    • .e e**********************

05/94 RF0 Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U-Bend i

Page 27 of 32 S/G D - ATTACHMENT #4 INDICATIONS OF IMPERFECTIONS ROW COL OUTAGE TEST TYPE IND %TW VOLTS LOCATION EXTENT 1 05/94 RF0 H/L Special Int VOL 2.39 7TH TSP

-10.46 7TH TSP 38 74 05/94 RF0 Bobbin 001 10 1.37 14TH TSP

+3.78 F/L 38 77 05/94 RF0 Bobbin 001 11 2.00 1ST TSP

+16.26 F/L 38 80 05/94 RF0 Bobbin 001 4

1.95 7TH TSP

+17.34 F/L 38 93 05/94 RF0 Bobbin WAR 28 1.77 2AVB

+0.00 F/L 39 18 05/94 RF0 Bobbin WAR 11 0.32 2AVB

+0.00 F/L 05/94 RF0 Bobbin WAR 15 0.48 1AVB

+0.00 F/L 05/94 RF0 Bobbin WAR 19 0.68 4AVB

+0.00 F/L 05/94 RF0 Bobbin WAR 39 3.20 3AVB

+0.00 F/L 05/94 RF0 U Bend VOL 1.64 3AVB

+0.00 97H TSP 39 19 05/94 RF0 Bobbin ODI 1.56 14TH TSP

+2.66 F/L 05/94 RF0 C/L Speciel Int VOL 0.3714TH TSP

'7.09 14TH TSP 39 23 05/94 RF0 Bobbin ADI 3.38 77H TSP

+25.99 F/L 05/94 RF0 H/L Special Int VOL 0.81 7TH TSP

+25.68 7TH TSP 39 28 05/94 PF0 Bobbin ADI 2.83 6TH TSP

+26.01 F/L 05/94 RF0 H/L Special Int VOL 0.62 6TH TSP

+8.02 6TH TSP 05/94 RF0 H/L Special Int VOL 0.72 6TH TSP

+26.30 6TH TSP 39 29 05/94 RF0 Bobbin ADI 4.00 7TH TSP

+29.76 F/L 05/94 RF0 H/L Special Int VOL 0.65 TTH TSP

+29.41 7TH TSP 39 38 05/94 RF0 Bobbin 001 5

0.64 177H TSP

+3.37 F/L 39 39 05/94 RF0 Bobbin ODI 2

0.49 13fH TSP

-6.25 F/L 05/94 RF0 Bobbin 001 13 1.57 17TH TSP

+3.82 F/L 39 41 05/94 RF0 Bobbin 001 5

1.86 4AVB

+8.95 F/L 39 44 05/94 RF0 Bobbin 001 6

1.10 BTH TSP

-2.37 F/L 05/94 RF0 Bobbin 001 22 0.50 15TH TSP 5.87 F/L 05/94 RF0 C/L Special Int VOL 0.71 1STH TSP

-5.85 15fH TSP 39 48 05/94 RF0 Bobbin ADI 6.84 1AVB

+ 25. 73 F/L 05/94 RF0 U Bend VOL 0.58 1AVB

+21.10 97H TSP 39 55 05/94 RF0 Bobbin 001 15 0.64 TTH TSP

-7.63 F/L I

39 61 05/94 RF0 Bobbin ADI 1.58 10TH TSP

+13.97 F/L 05/94 RF0 C/L Speclat Int VOL 4.24 10TH TSP

+12.98 10TH TSP 39 62 05/94 RF0 Bobbin ADI 10.62 1AVB

+13.90 F/L 05/94 RF0 U-Bend VOL 2.00 1AVB

+14.56 2AVB 05/94 RF0 Bobbin ADI 1.81 7TH TSP

+25.66 F/L 05/94 RF0 Bobbin 001 21 1.33 14TH TSP

-11.49 F/L 05/94 RF0 H/L Special Int VOL 1.49 7TH TSP

+26.83 BTH TSP 39 63 05/94 RF0 Bobbin DDI 13 1.82 BTH TSP

+2.07 F/L 05/94 RF0 U Bend VOL 0.85 BTH TSP

+1.15 BTH TSP 05/94 RF0 U-Bend VOL 0.98 BTH TSP

+2.04 BTH TSP 05/94 RF0 U Bend VOL 1.12 BTH TSP

+2.66 BTH TSP 05/94 RF0 U-Bend VOL 4.24 BTH TSP

-0.77 BTH TSP 39 64 05/94 RTO Bobbin ADI 3.11 1ST TSP

-3.31 F/L 05/94 RF0 Bobbin ADI 5.08 1ST TSP

-1.14 F/L g

05/94 RF0 Bobbin 001 34 0.76 BTH TSP

+1.97 F/L t

05/94 RFO H/L Special Int VOL 0.23 1ST TSP

-2.93 1ST TSP 05/94 RF0 H/L Special Int VOL 0.75 1ST TSP

-0.90 1ST TSP 39 68 05/94 RF0 Bobbin 001 6

1.74 1ST 7tP

+16.61 F/L 30 70 05/94 RF0 Bobbin ODI 5

1.70 3RD TSP

+21.15 F/L 39 76 05/94 RF0 Bobbin ADI 3.91 6TH TSP

+33.61 F/L 05/94 RF0 H/L Special Int VOL 0.51 7TH TSP

-9.25 7TH TSP 39 78 05/94 RF0 Bobbin 001 7

0.59 6TH TSP

+31.27 F/L

[

05/94 RF0 Bobbin DDI 22 1.19 3RD TSP

-7.89 F/L 39 80 05/94 RF0 Bobbin 001 25 1.07 1AVB

+6.16 F/L 39 SS 05/94 RF0 Bobbin ODI 9

1.30 12TH TSP

-10.70 F/L 39 90 05/94 RF0 Bobbin 001 27 0.40 71H TSP

+40.42 F/L 40 21 05/94 RF0 Bobbin ADI 1.83 10TH TSP

+ 7. 45 F/L 05/94 RF0 C/L Special Int VOL 0.3710TH TSP

+7.79 10TH TSP 40 24 05/94 RF0 Bobbin Nol 1.63 4TH TSP

+9.56 F/L i

05/94 RF0 Bobbin 001 21 1.65 17TH TSP

+1.66 F/L i

05/94 RF0 H/L Special Int VOL 0.43 4TH TSP

+15.66 4TH TSP 4

05/94 RF0 H/L Special Int VOL 0.70 4TH TSP

+9.37 4TH TSP 40 25 05/94 RF0 Bobbin DDI 2

1.73 1STH TSP

+3.29 F/L 40 28 05/94 RF0 Bobbin ADI 21.86 BTH TSP

+2.47 F/L 05/94 RF0 Bobbin 001 3

1.62 13TH TSP

+4.84 F/L 05/94 RF0 U-Bend VOL 1.54 BTH TSP

+3.16 BTH TSP 40 31 05/94 RF0 Bc5 bin 001 28 0.79 10TH TSP

+5.67 F/L l

......e*********************

BWNS TUBAN 11 (Version 2.0) 06/17/1994 06:39:09 se**************************

Catawba Nuclear Station - Unit Two e.......********************

S/G D e.............**************

05/94 RF0 Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet.U Bend eee............*************

Page 28 of 32 S/G D - ATTACHMENT #4 INDICATIONS OF IMPERFECTIONS RDW COL DUTAGE TEST TYPE IND %TW VOLTS LOCATION EXTENT 1 40 37 05/94 RF0 Bobbin NQI 0.31 10TH TSP

+41.75 F/L 05/94 RF0 Bobbin NQ1 0.59 'Old TSP

+37.%3 F/L 05/94 RF0 Bobbin DDI 12 1.09 10TH TSP

+38.c F/L 05/94 RF0 C/L Special Int VOL 0.86 9T H T SP 6.90 9TH TSP 05/94 RFC C/L Special Int VOL 0.99 91H TSP 8.01 91H TSP 05/94 RF0 C/L Spectat Int VOL 1.25 9TH TSP

-3.23 97H TSP 40 44 05/94 RFC Bobbin 001 4

0.69 7TH TSP

+32.81 F/L 40 48 05/94 RF0 Bobbin DDI 4

0.76 11TH TSP

+28,13 F/L 05/94 RF0 Bobbin 001 8

0.4014TH TSP

+11.70 F/L 40 56 05/94 RF0 Bobbin 001 13 1.02 14TH TSP

+12.06 F/L 05/94 RF0 C/L Special Int VOL 0.41 1BTH TSP

-0.98 18TH TSP 40 63 05/94 RF0 Bobbin DDI 11 0.99 71H TSP

-1.96 F/L 05/94 RF0 H/L Special Int VOL 1.19 TTH TSP

-1.99 7TH TSP 40 64 05/94 RF0 Bobbin 001 25 5.04 2AVB

+15.50 F/L 05/94 RF0 U-Bend VOL 1.64 2AVB

+16.21 3AVB 05/94 RF0 Bobbin 001 1

1,49 10TH TSP

+24.24 F/L 05/94 RF0 C/L Special Int VOL 0.44 10TH TSP

+23.12 10TH TSP 40 66 05/94 RF0 Bobbin ADI 9.02 2ND TSP

+27.95 F/L 05/94 RF0 H/L Special Int VOL 1.42 2ND TSP

+28.52 2ND TSP 40 67 05/94 RF0 Bobbin ODI 31 0.49 10TH TSP

+37.56 F/L 05/94 RFC Bobbin DDI 48 0.3910TH TSP

+38,12 F/L 05/94 RF0 C/L Special int VOL 1.98 9TH TSP

-3.99 YTH TSP 05/94 RF0 C/L Special Int VOL 4.60 97H TSP

-4,53 9TH TSP 40 84 05/94 RFC Bobbin NQ1 0.88 BTH TSP

+33.74 F/L 40 88 05/94 RF0 Bobbin ADI 3.92 9TH TSP

+10.51 F/L 40 57 05/94 RF0 Bobbin DDI 6

0.65 3RD TSP

+29.62 F/L 05/94 RFO Bobbin 001 6

1.22 10TH TSP

+1.38 F/L 05/94 RFC Bobbin 001 10 0.60 13TH TSP

+9,97 F/L 05/94 RF0 Bobbin DDI 15 0.26 13TH TSP

+11.00 F/L 05/94 RF0 C/L Spectat Int VOL 0.48 10TH TSP

+1.35 10TH TSP 41 28 05/94 RF0 Bobbin ADI 4.35 11TH TSP

+28.27 F/L 05/94 RTO C/L Special Int VOL 0.59 10TH TSP

-15.50 10TH TSP 41 29 05/94 RF0 Bobbin DDI 6

0.72 TTH TSP

+31.91 F/L 41 33 05/94 RF0 Bobbin NOI 0.58 2ND TSP

+8.46 F/L 05/94 RF0 H/L Special Int VOL 0.76 2ND TSP

+8.89 3RD TSP 41 38 05/94 RF0 Bobbin 001 5

0.81 11TH TSP

+11.14 F/L 41 40 05/94 RF0 Bobbin 001 1

0.64 15fH TSP

+13.12 F/L 05/94 RFC C/L Special Int VOL 0.3715TH TSP

+12.88 15TH TSP 41 43 05/94 RF0 Bobbin No!

1.68 2AVB

+24.33 F/L 05/94 RF0 Bobbin 001 42 0.70 11TH TSP

+29.15 F/L 05/94 RF0 C/L Special Int VOL 0.20 10TH TSP

-13.74 10TH TSP 05/94 RF0 C/L Special Int VOL 0.2710TH TSP

-15.63 10TH TSP 05/94 RF0 C/L Special Int VOL 0.64 10TH TSP

-11.46 10TH TSP 41 59 05/94 RF0 Bobbin 001 2

0.90 14TH TSP

-7.80 F/L 05/94 RF0 C/L Special Int VOL 0.32 14TH TSP

-7.80 14TH TSP 41 60 05/94 RF0 Bobbin 001 8

2.35 6TH TSP

+18.40 F/L 41 63 05/94 RF0 Bobbin 001 33 2.28 1AVB

+10.17 F/L 05/94 RF0 Bobbin ADI 6.2317TH TSP

+B.16 F/L 05/94 RF0 Bobbin No!

0.60 13TH TSP

+8.52 F/L 05/94 RF0 Bobbin NQI 0.80 13TH TSP

+9.71 F/L 05/94 RF0 C/L Special Int VOL 0.85 13TH TSP

+B.64 13TH TSP 05/94 RF0 C/L Special Int VOL 1.0313TH TSP

+10.00 13TH TSP 05/94 RF0 C/L Special Int VOL 3.0317TH TSP

+7.94 17TH TSP 41 67 05/94 RF0 Bobbin No!

0.66 71H TSP

+6.76 F/L 05/94 RF0 H/L Special Int VOL 0.48 71H TSP

+ 7. 02 BTH TSP 41 68 05/94 RF0 Bobbin No!

0.63 6TH TSP

+37.48 F/L 05/94 RF0 H/L Specist Int VOL 0.88 6TH TSP

+38.91 6TH TSP 41 69 05/94 RF0 Bobbin No!

1.16 2AVB

+17.71 F/L 05/94 RF0 U-Bend VOL 0.97 2AVB

+19.21 4AVB 05/94 RTO Bobbin N01 1.05 1ST TSP

+25.52 F/L 05/94 RF0 Bobbin NQI 1.49 2ND TSP

+16.96 F/L 05/94 RF0 Bobbin ODI 26 2,08 STH TSP

+30.55 F/L 05/94 RF0 P/L Special Int VOL 0.85 STH TSP

+31.35 STH TSP 05/94 RTO H/L Special Int VOL 0.95 1ST TSP

+26.08 1ST TSP 05/94 RFC H/L Special Int VOL 1.20 2ND TSP

+17.31 2ND TSP 41 70 05/94 RF0 Bobbin 001 19 0.29 7TH TSP

+33.79 F/L k

1

'""5 'ua^" ii (version z o) 06/'7/1994 o6:39:09 cata ba "uci ar Station - unit imo 03,ia o s

94 Rr0 Bobbin,C/L Specist Interest,H/L Special Interest,H/L Tubesheet,U Bend J

Page 29 cf 32 S/G 0 - ATTACHMENT #4 INDICATIONS OF IMPERFECTIONS ROW COL DUTAGE TEST TYPE IND %TW VOLTS LOCATION EXTENT 1 41 72 05/94 RF0 Bobbin No!

0.46 7TH TSP

+29.80 F/L 05/94 RF0 H/L Special Int VOL 0.27 BTH TSP 8.50 BTH TSP 05/94 RF0 H/L Spectat Int VOL 0.41 BTH TSP 14.13 BTH TSP 41 81 05/94 RF0 Bobbin 001 5

1.5010TH TSP

+19.45 F/L i

41 84 05/94 RF0 Bobbin 001 6

1.10 BTH TSP

+2.33 F/L t

41 87 05/94 RF0 Bobbin No!

0.71 1ST TSP

+16.54 F/L 41 88 05/94 RF0 Bobbin 001 1

1.45 BTH TSP

+2.62 F/L 05/94 RF0 Bobbin 001 9

2.54 6TH TSP

+6.42 F/L 41 89 05/94 RF0 Bobbin 001 35 1.30 BTH TSP

+2.57 F/L l

41 90 05/94 RTO Bobbin DDI 2

0.66 10TH TSP

+32.36 F/L 05/94 RF0 Bobbin 001 8

3.45 13TH TSP

-6.35 F/L 05/94 RF0 C/L Special Int VOL 0.77 13fH TSP

-6.74 13TH TSP 05/94 RF0 C/L Speclot Int VOL 1.39 10TH TSP

+25.15 10TH TSP 41 93 05/94 RFO Bobbin 001 37 1.22 7TH TSP

+35.42 F/L 05/94 RF0 H/L Special Int VOL 1.46 BTH TSP

-5.83 BTH TSP 42 23 05/94 RF0 Bobbin WAR 21 0.94 2AVB

+0.00 F/L 42 26 05/94 RF0 Bobbin NQI 0.83 11TH TSP

+28.96 F/L 05/94 RF0 C/L Special int VOL 0.51 10TH ISP

-14.54 10TH TSP 42 39 05/94 RF0 Bobbin 001 11 1.02 12TH TSP

+26.21 F/L 42 54 05/94 RF0 Bobbin Nol 1.04 91H TSP

+1.93 F/L 42 55 05/94 RF0 Bobbin ODI 1

0.93 14TH TSP

+13.56 F/L 42 59 05/94 RF0 Bobbin 001 22 0.54 3AVB

+23.19 F/L 05/94 RF0 Bobbin DDI 1

0.55 1ST TSP

+5.37 F/L 42 61 05/94 RTO Bobbin 001 7

0.57 IlTH TSP

+17.82 F/L 05/94 RF0 Bobbin DDI 8

0.56 111H TSP

+18.94 F/L 05/94 RF0 Bobbin ODI 14 0.59 11TH TSP

+29.46 F/L 05/94 RF0 Bobbin 001 16 0.53 11TH TSP

+28.21 F/L 42 62 05/94 RF0 Bobbin A01 4.67 14TH TSP

-2.96 F/L i

05/94 RF0 C/L Special Int VOL 2.69 14TH TSP

-3.44 14TH TSP 42 67 05/94 RF0 Bobbin 001 1

4.62 STH TSP 8.52 F/L 05/94 RF0 H/L Special Int VOL 1.54 STH TSP

-8.00 STH TSP 42 68 05/94 Rr0 Bobbin 001 12 2.39 3RD TSP

+21.92 F/L 42 69 05/94 RF0 Bobbin 001 18 0.85 77H TSP

+36.29 F/L 42 70 05/94 RF0 Bobbin 001 6

1.27 3RD TSP

+9.30 F/L 42 71 05/94 RF0 Bobbin 001 15 1.04 7TH TSP

+18.39 F/L 42 77 05/94 RF0 Bobbin 001 11 1.41 15TH TSP

+14.61 F/L 42 82 05/94 RF0 Bobbin 001 7

1.50 7TH TSP

+39.07 F/L 42 83 05/94 RF0 Bobbin 001 8

0.93 STH TSP

+39.83 F/L 05/94 RF0 Bobbin 001 12 1.16 STH TSP

+39.44 F/L 42 93 05/94 RF0 Bobbin 001 20 0.48 7TH TSP

+37.82 F/L 43 22 05/94 RF0 Bobbin WAR 24 1.19 4AVB

+0.00 F/L 05/94 RF0 Bobbin WAR 29 1.73 3AVB

+0.00 F/L 43 61 05/94 RF0 Bobbin 001 10 0.55 10TH TSP

+15.51 F/L 43 70 05/94 RF0 Bobbin 001 14 0.78 7TH TSP

+15.55 F/L 05/94 RF0 Bobbin 001 29 0.29 6TH TSP

+ 3 9. 86 F/L 43 72 05/94 RF0 Bobbin No!

0.87 3AVB

+13.31 F/L 43 73 05/94 RF0 Bobbin No!

0.76 BTH TSP

+10.90 F/L 05/94 RF0 Bobbin NOI 0.78 1ST TSP

+21.58 F/L 05/94 RTO U Bend VOL 0.49 BTH TSP

+11.12 BTH TSP 05/94 RF0 H/L Special Int VOL 1.21 2ND TSP

-5.02 2ND TSP 43 74 05/94 RF0 Bobbin No!

1.18 4TH TSP

+14.10 F/L 05/94 RFO H/L Spectat Int VOL 1.36 4TH TSP

+14.11 STH TSP 43 78 05/94 RF0 Bobbin WAR 24 1.42 2AVB

+0.00 F/L 05/94 RF0 Bobbin WAR 29 2.04 3AVB

+0.00 F/L 05/94 RF0 U Bend VOL 0.58 2AVB

+0.00 3AVB r

05/94 RF0 U-Bena VOL 0.78 3AvB

+0.00 3AVB 43 81 05/94 RF0 Bobbin WAR 17 0.83 4AVB

+0.00 F/L 05/94 RF0 Bobbin WAR 21 1.09 2AVB

+0.00 F/L 05/94 RF0 Bobbin WAR 30 2.21 3AVB

+0.00 F/L 05/94 RF0 U Bend VOL 0.23 4AVB

+0.00 97H TSP 05/94 RFO U Bend V0t 0.24 3AVB

+0.00 9TH TSP 05/94 RF0 U Bend VOL 0.35 2AVB

+0.00 97H TSP 43 85 05/94 RF0 Bobbin No!

0.53 7TH TSP

+39.38 F/L 43 87 05/94 RF0 Bobbin NO!

0.49 7TH TSP

+39.86 F/L 43 91 05/94 RF0 Bobbin NQ1 0.92 3RD TSP

+1.67 F/L 05/94 RF0 H/L Special Int VOL 0.60 3RD TSP

+1.68 4TH TSP

R eeeeee *********************

BWNS TUBAN 11 (Version 2.0) 06/17/1994 06:39:09 l

eeeeeeeee*******************

Catawba Nuclear Station - Unit two

)

eeeeee...... **............

Sfg n 05/94 RF0 Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U-Bend

    • eeeeee...*****************

l Page 30 of 32

$/G D - ATTACHMENT #4 INDICATIONS of IMPERFECTIONS ROW COL DUTAGE TEST TYPE IND %TW VOLTS LOCATION EXTENT 1 i

44 38 05/94 RF0 Bobbin 001 1

1.28 7TH TSP

+41.45 F/L 44 46 05/94 RF0 Bobbin WAR 15 0.58 3AVB

+0.00 F/L 44 54 05/94 RF0 Bobbin 001 17 1.3'. 8TH TSP

+2.49 F/L 44 59 05/94 RF0 Bobbin No!

1.00 BTH TSP

+2.41 F/L I

44 62 05/94 RF0 Bobbin DDI 12 2.21 4TH TSP

+38.47 F/L 44 64 05/94 RF0 Bobbin 00!

17 0.56 STH TSP

+40.54 F/L 05/94 RF0 H/L Special Int VOL 0.18 6TH TSP

-2.13 6TH TSP 44 69 05/94 RF0 Bobbin DDI 4

0.72 STH TSP

+37.64 F/L 44 76 05/94 RF0 Bobbin 001 2

2.35 6TH TSP

+24.05 F/L 44 80 05/94 RF0 Bobbin 001 13 1.18 9TH TSP

+2.52 F/L 05/94 RF0 U-Bend VOL 0.54 97H TSP

+2.67 9TH TSP 44 85 05/94 RF0 Bobbin NQI 1.36 BTH TSP

+2.65 F/L 05/94 RF0 U-Bend VOL 0.70 BTH TSP

+2.68 BTH TSP 44 90 05/94 RF0 Bobbin 001 8

0.58 10TH TSP

+38.70 F/L 45 24 05/94 RF0 Bobbin 001 12 2.00 1STH TSP

+25.68 F/L 45 27 05/94 RF0 Bobbin No!

0.28 12TH TSP

+30.60 F/L 05/94 RF0 C/L Special Int VOL 0.17 11TH TSP

-12.30 11TH TSP 45 35 05/94 RF0 Bobbin DDI 4

1.24 7TH TSP

+23.62 F/L 05/94 RF0 Bobbin 001 4

1.93 7TH TSP

+40.08 F/L 05/94 RF0 Bobbin 001 34 0.56 7TH TSP

+23.34 F/L 45 40 05/94 RF0 Bobbin Nc!

1.58 9TH TSP

+2.26 F/L 45 42 05/94 RF0 Bobbin 001 12 0.54 15TH TSP

+I3.02 F/L 45 52 05/94 RF0 Bobbin DDI 8

3.06 10TH TSP

+1.34 F/L 05/94 RFC Bobbin 0D1 33 0.37 17TH TSP

+8.51 F/L 05/94 RF0 Bobbin 001 35 0.88 11TH TSP

+17.12 F/L 05/94 RF0 C/L Special Int VOL 0.84 11TH TSP

+17.42 11TH TSP 45 73 05/94 RF0 Bobbin 001 21 1.36 13TH TSP

+28.02 F/L 05/94 RF0 C/L Special Int VOL 1.57 13TH TSP

+28.04 13TH TSP 45 78 05/94 RF0 Bobbin No!

0.52 13TH TSP

+5.30 F/L 45 79 05/94 RF0 Bobbin 001 21 1.32 4AVB

-20.66 F/L 45 83 05/94 RF0 Bobbin ODI 7

1.44 97H TSP

+2.49 F/L 05/94 RF0 U-Bend VOL 0.73 9TH TSP

+2.53 9TH TSP l

45 86 05/94 RF0 Bobbin NQI 1.12 9TH TSP

+1.40 F/L 45 91 05/94 RF0 Bobbin WAR 14 0.66 4AVB

+0.00 F/L 46 48 05/94 RF0 Bobbin No!

1.19 2AVB

+21.53 F/L 05/94 RF0 Bobbin Nol 2.39 3AVB

+1.09 F/L 05/94 RF0 Bobbin 001 17 0.98 1AVB

+22.65 F/L 05/94 RF0 Bobbin 001 24 2.10 2AVB

+9.95 F/L 05/94 RF0 Bobbin 001 28 2.19 1AVB

+31.10 F/L 05/94 RF0 U-Bend VOL 1.18 2AVB

+30.25 1AVB j

05/94 RF0 U Bend VOL 1.19 2AVB

+8.73 1AVB 05/94 RF0 U-Bend VOL 1.24 3A /B

+0.87 1AVB 05/94 RF0 U-Bend VOL 2.20 1AVB

+20.59 1AVB 05/94 RFC U Bend VOL 3.29 1AVB

+28.43 1AVB 46 51 05/94 RF0 Bobbin 001 9

0.78 12TH TSP

+6.31 F/L 46 61 05/94 RF0 Bobbin ODI 6

0.76 11TH TSP

+41.20 F/L 46 63 05/94 RF0 Bobbin ADI 5.51 1AVB

+30.67 F/L 05/94 RF0 Bobbin ODI 9

4.46 1AVB

+27.37 F/L 05/94 RF0 Bobbin 001 15 3.13 2AVB

+8.41 F/L 05/94 RF0 U-Bend VOL 0.80 1AVB

+30.29 2AVB 46 81 05/94 RF0 Bobbin DDI 11 0.85 17TH TSP

+25.22 F/L 47 27 05/94 RF0 Bobbin 001 4

1.02 6TH TSP

+7.74 F/L 05/94 RF0 Bobbin 001 5

1.62 71H TSP

+36.56 F/L 47 34 05/94 RF0 Bobbin Nol 1.21 1AVB

+11.14 F/L 05/94 RF0 Bobbin No!

1.22 1AVB

+17.37 F/L 05/94 RF0 Bobbin NQ1 1.56 1AVB

+15.29 F/L i

05/94 RF0 Bobbin NQ1 1.90 1AVB

+19.15 F/L l

05/94 RF0 Bobbin 001 13 1.17 1 AVB

+9.30 F/L 05/94 RF0 U-Bend VOL 0.47 1AVB

+9.52 2AVB 05/94 RF0 U-Bend VOL 0.62 1AVB

+12.79 2AVB 05/94 RF0 U Bend VOL 0.71 1AVB

+16.22 2AVB 05/94 RF0 U-Bend VOL 0.74 1AVB

+ 7. 94 2AVB 05/94 RF0 U Bend VOL 0.80 1AVB

+14.68 2AVB 05/94 RF0 U Bend VOL 0.78 BTH TSP

+22.73 2AVB 05/94 RF0 U Bend VOL 0.88 BTH TSP

+11.58 2AVB 47 41 05/94 RF0 Bobbin 001 7

1.12 9TH TSP

+2.33 F/L l

i L

BWNS TUBAN 11 (Version 2.0) 06/17/1994 06:39:09 eeeeeeeeeeeeee.*************

Catawba Nuclear Station - Unit Two eeeeee...............*******

S/G 0 05/94 RF0 Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U Bend eeee***e..u..........******

Page 31 of 32

$/G D - ATTACHMENT #4 IN0! CATIONS OF IMPERFECTIONS

]

ROW COL OUTAGE TEST TYPE IND %TW VOLTS LOCAfl0N EXTENT 1

]

47 43 05/94 RF0 Bobbin 001 9

1.16 97H TSP

-1.81 F/L 47 46 05/94 RF0 Bobbin 001 12 0.65 9TH TSP

-1.41 F/L 47 65 05/94 RF0 Bobbin 001 11 1.41 STH TSP

+24.99 F/L i

47 67 05/94 RF0 Bobbin 001 24 0.58 7TH TSP

+35.06 F/L 1

47 68 05/94 RF0 Bobbin ADI 8.74 3AVB

+9.54 F/L 05/94 RF0 Bobbin NO!

1.19 9TH TSP

+2.35 F/L 05/94 RF0 Bobbin 001 34 0.71 71H TSP

+30.03 F/L 05/94 RF0 U Bend VOL 1.02 4AVB

+28.19 9TH TSP 47 81 05/94 RF0 Bobbin 001 22 2.16 2AVB

+5.33 F/L 47 83 05/94 RF0 Bobbin ADI 3.1717TH TSP

+23.85 F/L 05/94 RF0 C/L Special Int VOL 0.33171H TSP

+26.09 17TH iSP j

47 87 05/94 RF0 Bobbin 001 20 0.59 4TH TSP

-2.13 F/L 4

48 32 05/94 RF0 Bobbin N:1 0.48 1/TH TSP

+12.04 FA 05/94 RF0 C/L Special Int VOL 0.36 171H tsp

+12.25 17TH TSP 48 33 05/94 RF0 Bobbin NQ1 0.52 13TH TSP

+3.28 F/L 05/94 RF0 C/L Special Int VOL 0.67 13fH TSP

+3.44 13TH TSP 48 35 05/94 RF0 Bobbin ODI 9

0.58 101H ISP + 3 7. 21 F/L 48 41 05/94 RF0 Bobbin 001 8

1.89 7TH TSP

+23.29 F/L 05/94 RF0 Bobbin ODI 18 0.65 7TH TSP

+22.19 F/L 48 44 05/94 RF0 Bobbin 001 1

1.58 4AVB 8.61 F/L 05/94 RF0 Bobbin NQ1 0.52 71H TSP

+36.07 F/L 05/94 RF0 Bobbin NO!

0.78 11TH TSP

+1.88 F/L 05/94 RF0 Bobbin N01 0.90 11TH TSP

+24.37 F/L 05/94 RF0 Bobbin NOI 1.04 15TH T$P

+26.29 F/L l

05/94 RF0 H/L Special Int VOL 0.73 BTH TSP

-22.15 BTH TSP l

05/94 RF0 C/L Special int Vol 0.28 131H TSP

-9.84 13fH TSP I

05/94 RF0 C/L Special Int VOL 0.48 13fH TSP

+0.00 13TH TSP 05/94 RF0 C/L Special Int VOL 0.63 11TH TSP

+24.20 11TH TSP I

05/94 RF0 C/L Special Int VOL 1.26 11TH TSP

+2.03 11TH TSP 48 56 05/94 RF0 C/L Special Int VOL 0.61 18TH TSP

-0.03 18TH TSP 48 62 05/94 RF0 Bobbin 001 28 0.48 li,iH TSP

+31.49 F/L 48 65 05/94 RF0 C/L Special Int VOL 0.97 18TH ISP

+3.39 181H TSP 05/94 RF0 C/L Special Int VOL 1.54 187H ISP

-2.54 18TH TSP 48 68 05/94 RF0 Bobbin 001 33 3.05 1AVB

+27.68 F/L i

48 70 05/94 RF0 Bobbin 00!

10 0.65 71H TSP

+26.48 F/L l

05/94 RF0 Bobbin 001 10 0.67 TTH TSP

+36.36 F/L 05/94 RF0 Bobbin 001 14 1.30 TTH TSP

+27.45 F/L 48 72 05/94 RF0 Bobbin A01 4.36 17TH TSP

+18.51 F/L 05/94 RF0 Bobbin ADI 6.08 111H TSP

+20.85 F/L 05/94 RF0 C/L Special Int VOL 0.38 17TH TSP

+19.09 171H TSP 05/94 RF0 C/L Special Int VOL 0.71 17TH TSP

+20.35 17TH TSP 48 75 05/94 RF0 H/L Tubesheet VOL 0.66 TTS-HL

+0.00 TTS-HL 48 78 05/94 RF0 Bobbin A01 6.09 4AVs

-0.57 F/L 05/94 RF0 U-Bend VOL 0.46 4AVB 0.20 9TH TSP 48 80 05/94 RF0 Bobbin NQ1 1.11 91H TSP

+1.49 F/L 48 84 05/94 RFO C/L Special Int VOL 18.45 18TH TSP

+0.00 187H TSP 49 33 05/94 RF0 Bobbin ODI 9

1.60 131H TSP

+5.85 F/L 49 37 05/94 RF0 Bobbin No!

0.74 121H TSP

+11.55 F/L 05/94 RF0 Bobbin 001 3

1.62 151H TSP

+24.92 F/L 05/94 RF0 C/L Special Int VOL 0.49 12TH TSP

+11.38 12TH TSP 49 47 05/94 RF0 C/L Special Int VOL 0.47 18TH TSP

+0.00 18TH TSP 49 48 05/94 RF0 Bobbin 001 11 1.36 8TH TSP

+3.47 F/L 49 51 05/94 RF0 Bobbin 001 8

0.60 15fH TSP

+19.89 F/L 05/94 RF0 Bobbin 001 14 1.8711TH ISP

+19.26 F/L 05/94 RF0 Bobbin 001 29 0.49 11TH TSP

+17,91 F/L 49 59 05/94 RF0 Bobbin ADI 2.36 77H TSP

+24.23 F/L 05/94 RFO H/L Special Int VOL 0.67 7TH TSP

+24.74 7TH TSP 49 67 05/94 RF0 Bobbin 001 2

2.66 9TH TSP 1.50 F/L 05/94 RF0 C/L Special I,t VOL 1.08 91H TSP

-1.83 9TH TSP 49 69 05/94 RF0 Bobbin 001 13 5.04 1AVB

'14.87 F/L 05/94 RFD U-Bend VOL 1.71 1AVB

+14.56 1AVB 05/94 RF0 C/L Special Int VOL 1.07 18TH TSP

-0.22 18TH TSP 05/94 RF0 C/L Special Int VOL 7.3817TH TSP

+0.00 17TH TSP 49 70 05/94 RF0 Bobbin NOI 1.04 BTH TSP

+3.58 F/L 49 72 05/94 RF0 C/L Special Int VOL 5.07 18TH TSP

+0.00 18TH TSP 49 79 05/94 RF0 C/L Special Int VOL 1.11 18TH TSP

+0.00 1STM TSP

--_---____--__________-_____________-_-_-___________________-______________m

l 1

BWNS TUBAN 11 (Version 2.0) 06/17/1994 06:39:09 ese**eeeeeeeeeeeeeeeee******

Catawba Nuclear Station - Unit Two eeeeeee*********************

S/G D eeeeeeeeeee...eeeeee*eee..

  • 05/94 RF0 Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U-Bend, i

l Page 32 of 32 S/G D - ATTACHMENT #4 INDICATIONS OF IMPERFECTIONS RDW COL DUTAGE TEST TYPE IND %TW VOLTS LOCATION EXTENT 1 49 83 05/94 RF0 Bobbin AXI 36 0.81 4TH TSP

+3.30 to

+5.27 F/L 05/94 RFO H/L Special Int VOL 0.43 4TH TSP

+4.72 4TH TSP 05/94 RF0 H/L Special Int VOL 0.59 4TH TSP

+3.56 4TH TSP Total Indications Found = 2049 Total Tubes Found = 903 l

l l

l l

l 4

I

)

I

I l

1 I

l l

l 1

ATI'ACllMENT 5 L

0 9

l l

l BWNS TUBAN II (Version 2.0) 06/17/1994 09:37:12 e**e*******************************

Catawba Nuclear Station - Unit Two eeeeeees...........................

Sfg g e**********************************

05/94 RF0 e.....................**...........

Page 1 S/G A - ATTACHMENT #5 TUBES PLUGGED OR REPAIRED ROW COL QUTAGE REPAIR CODE TYPE LOCATION LENGTH MATL LEG 8 107 05/94 RF0 PLG ROLL 1690 TE-CL 05/94 RF0 PLC ROLL 1690 TE HL 16 72 05/94 RF0 PLG ROLL 1690 TE CL 05/94 RF0 PLG ROLL 1690 TE HL 24 108 05/94 RFO PLG ROLL 1690 TE-CL 05/94 RF0 PLG ROLL 1690 TE-HL 29 24 05/94 RF0 PLG ROLL 1690 TE-CL 05/94 RF0 PLG ROLL 1690 TE HL 35 14 05/94 RF0 PLG ROLL 1690 TE-CL 05/94 RF0 PLG ROLL 1690 TE HL 40 72 05/94 RF0 PLG ROLL 1690 TE-CL 05/94 RF0 PLG ROLL 1690 TE-HL Total Indications Found = 12 Total Tubes Found a 6 Total Tubes in input File a 6

1 L

P L

I ATTACIIMENT 6 i

l i

4 e-i 1

l i

l i

l i

l I

BWNS TUBAN II (Version 2.0) 06/17/1994 07:07:19 Catawba Nuclear Station - Unit Two eeeeeeee***...........**...........

sfg g 05/94 RF0 eeeeeeee*.................**......

Page 1

$/G B - ATTACHMENT #6 TUBES PLUGGED OR REPAIRED ROW COL QUTAGE REPA!R CODE TYPE LOCATION LENGTH MATL LEG 7

29 87 05/94 RF0 PLG ROLL 1690 TE CL 05/94 RF0 PLC ROLL 1690 TE-HL 30 90 05/94 RF0 PLG ROLL 1690 TE CL 05/94 RF0 PLG ROLL 1690 TE HL 33 68 05/94 RF0 PLG ROLL 1690 TE-CL 05/94 RFO PLG ROLL 1690 TE HL 33 74 05/94 RF0 PLG ROLL 1690 TE-CL 05/94 RF0 PLG ROLL 1690 TE-HL 33 78 05/94 RFC PLG ROLL 1690 TE CL 05/94 RF0 PLG ROLL 1690 TE-HL 37 35 05/94 RFO PLG ROLL 1690 TE-CL 05/94 RF0 PLG ROLL 1690 TE-HL 38 82 05/94 RF0 PLG ROLL 1690 TE-CL 05/94 RF0 PLG ROLL 1690 TE-HL 40 64 05/94 RF0 PLG ROLL 1690 TE-CL 05/94 RF0 PLG ROLL 1690 TE-HL 41 64 05/94 RF0 PLG ROLL 1690 TE-CL 05/94 RF0 PLG ROLL 1690 TE-HL 45 37 05/94 RF0 PLG ROLL 1690 TE-CL 05/94 RF0 PLG ROLL 1690 TE-HL 47 80 05/94 RF0 PLG ROLL 1690 TE-CL 05/94 RF0 PLG ROLL 1690 TE-HL Total Indications found = 22 Total Tubes found = 11 Total Tubes in input File = 11 1

c

)

i I

l ATTACIIMENT 7 I

eeeeeeeeeeeeeeeeeeee*ee...........e ggus yVBAN II (Version 2.0) 06/17/1994 07:03:33 eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee**

Catawba Nuclear Station - Unit Two eeeeeee***......*******************

S/G C 05/94 RF0 e....ee...........................

1 Page 1

$/G C - ATTACHMENT #7 TUBES PLUGGED OR REPAlRED ROW COL OUTAGE REPAIR CODE TYPE LOCATION LENGTH MATL LEG 9 35 05/94 RF0 PLG ROLL 1690 TE CL 05/94 RF0 PLG ROLL 1690 TE HL i

33 24 05/94 RF0 PLG ROLL 1690 TE-CL 05/94 RF0 PLG ROLL 1690 TE ML 39 20 05/94 RF0 PLC ROLL 1690 TE CL 05/94 RF0 PLG ROLL 1690 TE-HL 39 47 05/94 RF0 PLG ROLL 1690 TE-CL 05/94 RF0 PLG ROLL 1690 TE-HL 46 87 05/94 RF0 PLG ROLL 1690 TE-CL 05/94 RF0 PLC ROLL 1690 TE-HL Total Indications Found = 10 Total Tubes found = 5 Total Tubes in input File = 5 l

i I

d

5 t

i i

ATTACliafENT 8 J

\\

eeeeeeeeeee************************

BWNS TUBAN !! (version 2.0) 06/17/1994 07:10:01 eeeeeeeeeeeeeeeeeeeeeeeeee*********

Catawba Nuclear Station - Unit Two eseeeeee.......

S/G 0 e*eeeeee**...e 05/94 RF0 c ************

eeeeeeee......

Page 1

$/G 0 - ATTACHMENT #8 TUBES PLUGGED OR REPAIRED ROW COL OUTAGE REPAIR CODE TYPE LOCATION LENGTH MATL LEG 4 43 05/94 RF0 PLG ROLL 1690 TE-CL 05/94 RF0 PLG ROLL 1690 TE-ML 15 108 05/94 RTO PLG ROLL 1690 TE-CL 05/94 RF0 PLC ROLL 1690 TE HL 16 62 05/94 RF0 PLG ROLL 1690 TE CL 05/94 RF0 PLG ROLL 1690 TE HL 21 110 05/94 RF0 PLG ROLL 1690 TE-CL 05/94 RF0 PLG ROLL 1690 TE HL 28 81 05/94 RF0 PLG ROLL 1690 TE-CL 05/94 RF0 PLC ROLL 1690 TE HL 30 59 05/94 RF0 PLG ROLL 1690 TE-CL 05/94 RF0 PLC ROLL 1690 TE HL 33 48 05/94 RIO PLG ROLL 1690 TE CL 05/94 RF0 PLG ROLL 1590 TE-HL 40 67 05/94 RF0 PLG ROLL 1690 TE-CL 05/94 RF0 PLG ROLL 1690 TE-HL 41 43 05/94 RF0 PLG ROLL 1690 TE CL 05/94 RF0 PLC ROLL 1690 TE-HL Total Indications Found = 18 Total Tubes Found = 9 Total lubes in input File = 9 I

I

-J