Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- RBG-15-181, Final Deficiency Rept DR-71 Re Inconsistencies in QA Program at Wj Woolley Co,Manufacturer of Personnel Air Locks. Initially Reported on 820827.No Physical Hardware Changes Necessary.Item Not Reportable Per 10CFR50.55(e) + (ML20072B117)
- NRC-94-4256, Forwards WCAP-14114, Human Performance in Operating Events: Lessons Learned for AP600 M-MIS Design, & WCAP-14115, Review of Nuclear Plant Operating Experience and Application to AP600 Design + (ML20072B119)
- ML20072B120 + (ML20072B120)
- ML20072B123 + (ML20072B123)
- ML20072B126 + (ML20072B126)
- 05000249/LER-1983-021-01, /01T-0:on 830523,differential Pressure Switches Ps 1349A & B Actuated Above Tech Spec Limit.Caused by Instrument Drift.Switches Reset.Trip Point Repeatability Verified + (ML20072B129)
- ML20072B130 + (ML20072B130)
- ML20072B137 + (ML20072B137)
- ML20072B139 + (ML20072B139)
- 05000254/LER-1983-021-01, /01T-0:on 830520,pinhole Leak Discovered on Reactor Continuous Head Vent Line.Caused by Slag Entrapment within Weld During Initial Installation.Indication Removed & Rewelded + (ML20072B140)
- ML20072B147 + (ML20072B147)
- ML20072B151 + (ML20072B151)
- 05000331/LER-1994-010, :on 940710,manual Scram Was Inserted in Response to Impending Loss of EHC Reservior Level.Caused by Crack in 1 EHC Tubing.Repaired Ruptured Tubing & Installed Accumulators on Cvs + (ML20072B154)
- ML20072B158 + (ML20072B158)
- 05000254/LER-1983-020-03, /03L-0:on 830510,while Performing Monthly Exercise Qos 1600-1,Div II Indicating Lights for Vacuum Breaker 1-1601-33F Did Not Operate When Valve Exercised.Caused by Slight Binding in Vacuum Breaker Main Shaft + (ML20072B164)
- 05000298/LER-1983-005-03, /03L-0:on 830505,scram Discharge Vol Drain Value CRD-CV-AOV33 Failed to Close Per Tech Specs.Caused by Grafoil Packing Working Between Valve Stem & Body.Valve Repacked + (ML20072B168)
- 05000369/LER-1983-025-03, /03L-0:on 830508,while in Mode 2,fire Detection Sys Zones 72 & 149 Declared Inoperable Due to Alarms Remaining in Alarm Condition.Fire Watch Patrols Established. Caused by Control Interface Module failure.W830527 Ltr + (ML20072B176)
- ML20072B177 + (ML20072B177)
- 05000249/LER-1983-017-03, /03L-0:on 830504,after Actuation of HPCI Deluge Sys,Weight Releasing Lever of Deluge Valve Tripped.Probably Caused by Misaligned Trip Linkage.Solenoid & Valve Linkage Disassembled/Assembled W/No Anomalies Noted + (ML20072B189)
- 05000237/LER-1983-039-03, /03L-0:on 830505,during Normal Operation, Unidentified Leak from Drywell Discovered.Caused by Packing Leak on Recirculation Discharge Bypass Valve 2-202-7A Causing Overflow of Equipment Drain Sump + (ML20072B195)
- ML20072B196 + (ML20072B196)
- 05000373/LER-1983-044-03, /03L-0:on 830505,reactor Water Ph Dropped Below Tech Spec While in Cold Shutdown.Suppression Pool & 1CY01T Contaminated W/Organics.Caused by Processing Freon & Organic Solvents Through Radwaste Into 1CY01T + (ML20072B198)
- ML20072B200 + (ML20072B200)
- ML20072B203 + (ML20072B203)
- 05000373/LER-1983-045-03, /03L-0:on 830506,during Reactor Vessel High Water Level HPCS Injection Valve Closure Calibr & Functional Test, Level Indicating Switch 1B21-N100A Found Out of Tolerance. Caused by Instrument Drift + (ML20072B206)
- ML20072B207 + (ML20072B207)
- ML20072B212 + (ML20072B212)
- ML20072B213 + (ML20072B213)
- ML20072B216 + (ML20072B216)
- ML20072B217 + (ML20072B217)
- PY-CEI-NRR-1837, Special Rept:On 940515 & 0618,ECCS Manual Actuations W/ Injection Into RCS Occurred as Part of Preplanned Activities for Testing + (ML20072B225)
- ML20072B235 + (ML20072B235)
- NRC-94-4245, Forwards Proprietary WCAP-14124 & Nonproprietary WCAP-14136, AP600 Low Pressure Integral Sys Test at or State Univ Facility Description Rept, Vols 1 & 2.WCAP-14124,Vols 1 & 2 Withheld (Ref 10CFR2.790) + (ML20072B240)
- ML20072B243 + (ML20072B243)
- ML20072B252 + (ML20072B252)
- ML20072B254 + (ML20072B254)
- 05000237/LER-1983-042-03, /03L-0:on 830512,condenser Low Vacuum Scram Switch 503D Tripped at Vacuum of 22.8 Inches While Performing Dis 500-6.Caused by Instrument Drift.Barksdale Switch DIT-H18SS Adjusted & Exercised + (ML20072B256)
- NG-83-1912, NPDES Noncompliance Notification:During Apr,Monthly Average Suspended Solids Effluent Concentration Exceeded Permitted Monthly Average.Caused by Large Number of Personnel Onsite to Support Refueling Outage + (ML20072B258)
- RBG-15-192, Interim Part 21 Rept DR-95 Re Possible Defect in Plate & Face Plate Gaskets for Morrison-Knudsen Co Hydrogen Ignitor, Model 6043.Initially Reported on 830204.Evaluation Not Completed.Next Rept to Be Submitted by 830711 + (ML20072B263)
- ML20072B265 + (ML20072B265)
- ML20072B269 + (ML20072B269)
- ML20072B275 + (ML20072B275)
- ML20072B282 + (ML20072B282)
- 05000237/LER-1983-037-03, /03L-0:on 830504,average Power Range Monitor 4 Rod Block Setpoint Exceeded Tech Spec Limit of 12%.Caused by Instrument Drift.Monitor Adjusted & Tested Satisfactorily + (ML20072B285)
- ML20072B287 + (ML20072B287)
- ML20072B291 + (ML20072B291)
- ML20072B292 + (ML20072B292)
- ML20072B296 + (ML20072B296)
- ML20072B305 + (ML20072B305)
- ML20072B307 + (ML20072B307)
- ML20072B317 + (ML20072B317)