Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20071F540 + (ML20071F540)
- ML20071F550 + (ML20071F550)
- ML20071F556 + (ML20071F556)
- ML20071F561 + (ML20071F561)
- ML20071F574 + (ML20071F574)
- 05000333/LER-1978-075, Forwards LER 78-075/03L-1 + (ML20071F577)
- 05000333/LER-1978-075-03, /03L-1:on 780902,during Surveillance Test F-ST-3D, Normally Closed Inboard Core Spray Injection Valve 14-MOV-12B Failed to Open Electrically,Causing Sys Inoperability.Caused by High Differential Pressure + (ML20071F581)
- ML20071F588 + (ML20071F588)
- 05000333/LER-1978-082, Forwards LER 78-082/03L-0 + (ML20071F599)
- 05000333/LER-1978-082-03, /03L-0:on 780920,during Refueling Shutdown, Pressure Suppression Pool Torus Level Increased to 0.8 Inches Above Tech Spec Limit.Caused by Leaking Past Seat of Safety Relief Valve + (ML20071F604)
- 05000333/LER-1978-056, Forwards LER 78-056/03L-1 + (ML20071F605)
- 05000333/LER-1978-056-03, /03L-1:on 780722,core Spray Sys Outboard Isolation Valve Would Not Close.Caused by Sheared Limitorque Shaft Key.Key Replaced + (ML20071F610)
- PMNS20200223, Notice of Meeting with Oklo, Inc + (ML20071F627)
- ML20071F632 + (ML20071F632)
- ML20071F665 + (ML20071F665)
- 05000285/LER-1978-032, Forwards LER 78-032/03L-0 + (ML20071F690)
- 05000285/LER-1978-032-03, /03L-0:on 781002,during Performance of ST-ESF-5, Timers SI-1B & CH-1B on Sequence S2-2 Failed to Time Out in Prescribed Time Limit.Caused by Stuck Operating Mechanism.Timers Exercised to Fee Mechanism + (ML20071F695)
- ML20071F702 + (ML20071F702)
- ML20071F703 + (ML20071F703)
- ML20071F713 + (ML20071F713)
- 05000333/LER-1978-087, Forwards LER 78-087/04T-0 + (ML20071F718)
- ML20071F722 + (ML20071F722)
- ML20071F730 + (ML20071F730)
- ML20071F737 + (ML20071F737)
- 05000458/LER-1994-013, :on 940602,normal Power Supply Breaker to HPCS 4,160 Volt Bus Tripped,Leading to Automatic Start & Load of Div II Dg.Caused by Personnel error.Multi-discipline Team Formed to Evaluate Maint Practices + (ML20071F738)
- ML20071F742 + (ML20071F742)
- ML20071F744 + (ML20071F744)
- ML20071F764 + (ML20071F764)
- ML20071F765 + (ML20071F765)
- ML20071F768 + (ML20071F768)
- ML20071F774 + (ML20071F774)
- ML20071F779 + (ML20071F779)
- ML20071F781 + (ML20071F781)
- ML20071F787 + (ML20071F787)
- 05000458/LER-1994-014, :on 940602,Div I BOP Containment Isolation Signal Generated During Replacment of Base of Relay Due to Inattention to Detail by Electrical Discipline Technical Specialist.Specialist Counseled + (ML20071F790)
- PY-CEI-NRR-1825, Confirms Previous Notification of Schedule Change for Corrective Action Documented in Response to NOV 93023-02, Involving Implementation of Maint Monitoring Program.Action Expected to Be Completed in Aug 1994 + (ML20071F801)
- ML20071F804 + (ML20071F804)
- ML20071F809 + (ML20071F809)
- NG-94-2113, Responds to GL 89-19 Re Info & Possible Actions on Reactor Vessel Overfill Protection + (ML20071F812)
- 05000333/LER-1978-086, Forwards LER 78-086/03L-0 + (ML20071F813)
- ML20071F814 + (ML20071F814)
- ML20071F817 + (ML20071F817)
- 05000333/LER-1978-086-03, /03L-0;on 781016,during Refuel Shutdown,Two Elec Conduits Passing Through Safety Related Area Fire Barrier Found to Be Improperly Sealed in Violation of Tech Spec. Both Penetrations Immediately Sealed + (ML20071F818)
- ML20071F822 + (ML20071F822)
- ML20071F828 + (ML20071F828)
- ML20071F839 + (ML20071F839)
- ML20071F845 + (ML20071F845)
- 05000285/LER-1978-033, Forwards LER 78-033/03L-0 + (ML20071F846)
- 05000285/LER-1978-033-03, /03L-0 on 781014:Reactor Coolant Cold Leg Temp Indicator B/122C Failed High Off Scale Because of an Open Circuited Rosemount Model 104VC Rtd.The RTD Will Be Replaced During Present Refueling Outage + (ML20071F854)
- 05000333/LER-1978-088, Forwards LER 78-088/04L-0 + (ML20071F860)
- 05000333/LER-1978-088-04, /04L-0 on 781024:excess Solute Release from Makeup Water Treatment Waste Neutralizer Tanks to Circulating Water Discharge Tunnel Detected.Caused by Unsound Sampling & Method of Determining Concentrations & Dissolved Solids + (ML20071F865)