| | | Reporting criterion |
|---|
| 05000285/LER-1978-005-03, /03L-1 on 780214:CH-1C Charging Pump Was Out for Maint on Leaking End Cap.Crack in Valve Block Noted.Pump Not Inoperable & Returned to Svc.Crack Due to Heavy Usage & Excessive Vibration.New Block Installed 790105 | /03L-1 on 780214:CH-1C Charging Pump Was Out for Maint on Leaking End Cap.Crack in Valve Block Noted.Pump Not Inoperable & Returned to Svc.Crack Due to Heavy Usage & Excessive Vibration.New Block Installed 790105 | |
| 05000285/LER-1978-005, Forwards LER 78-005/03L-1 | Forwards LER 78-005/03L-1 | |
| 05000285/LER-1978-012-03, /03L-1 on 781229:during Routine Maint of Charging Pump CH-1B,crack in Valve Block at Piston 3 Was Found.Caused by Excessive Vibration During Operation | /03L-1 on 781229:during Routine Maint of Charging Pump CH-1B,crack in Valve Block at Piston 3 Was Found.Caused by Excessive Vibration During Operation | |
| 05000285/LER-1978-012, Forwards LER 78-012/03L-1 | Forwards LER 78-012/03L-1 | |
| 05000285/LER-1978-026-03, /03L-1 on 780830:Bchannel RPS Variable Overpwr Trip Reset Demand Alarm Actuated & Would Not Reset.Then,Hi Pwr & Thermal Margin/Low Pressure Trip Units Failed,Both Due to Failure of Devar19-601A,18volt Pwr Supply | /03L-1 on 780830:Bchannel RPS Variable Overpwr Trip Reset Demand Alarm Actuated & Would Not Reset.Then,Hi Pwr & Thermal Margin/Low Pressure Trip Units Failed,Both Due to Failure of Devar19-601A,18volt Pwr Supply | |
| 05000285/LER-1978-026, Forwards LER 78-026/03L-1 | Forwards LER 78-026/03L-1 | |
| 05000285/LER-1978-028, Forwards LER 78-028/03L-0 | Forwards LER 78-028/03L-0 | |
| 05000285/LER-1978-028-03, /03L-0 on 780831:failure of Tri-x Weather Towers 100 Meter Delta-T Sensor Sys to Rept Stability Class Info. Calibrations Revised to Ensure Instruments Detect Subsequent Sensor Sys Failures | /03L-0 on 780831:failure of Tri-x Weather Towers 100 Meter Delta-T Sensor Sys to Rept Stability Class Info. Calibrations Revised to Ensure Instruments Detect Subsequent Sensor Sys Failures | |
| 05000285/LER-1978-029, Forwards LER 78-029/03L-0 | Forwards LER 78-029/03L-0 | |
| 05000285/LER-1978-029-03, /03L-0 on 780908:Inadvertent Radioactive Gas Release to Atmosphere Caused by Leakage Past Check Valve CH-284,HG-100 & Relief Valve HG-105.Valves Will Be Inspected & Replaced or Repaired During Next Refueling Outage | /03L-0 on 780908:Inadvertent Radioactive Gas Release to Atmosphere Caused by Leakage Past Check Valve CH-284,HG-100 & Relief Valve HG-105.Valves Will Be Inspected & Replaced or Repaired During Next Refueling Outage | |
| 05000285/LER-1978-030-01, /01T-0 on 781003:During Oper Check on Auxiliary Steam Driven Feed Pump,The Steam Inlet Valve YCV-1045 Did Not Open Due to Closed Air Supply | /01T-0 on 781003:During Oper Check on Auxiliary Steam Driven Feed Pump,The Steam Inlet Valve YCV-1045 Did Not Open Due to Closed Air Supply | |
| 05000285/LER-1978-030, Forwards LER 78-030/01T-0 | Forwards LER 78-030/01T-0 | |
| 05000285/LER-1978-031, Forwards LER 78-031/03X-1 | Forwards LER 78-031/03X-1 | |
| 05000285/LER-1978-031-03, /03X-1 on 780918:during Refueling Outage,D Channel Hot Leg Temp Indication Was Investigated to Determine Cause of 780918 Failure.Failure Caused by Rosemount Model 104VC RTD Having Water in the Pothead | /03X-1 on 780918:during Refueling Outage,D Channel Hot Leg Temp Indication Was Investigated to Determine Cause of 780918 Failure.Failure Caused by Rosemount Model 104VC RTD Having Water in the Pothead | |
| 05000285/LER-1978-032-03, /03L-0:on 781002,during Performance of ST-ESF-5, Timers SI-1B & CH-1B on Sequence S2-2 Failed to Time Out in Prescribed Time Limit.Caused by Stuck Operating Mechanism.Timers Exercised to Fee Mechanism | /03L-0:on 781002,during Performance of ST-ESF-5, Timers SI-1B & CH-1B on Sequence S2-2 Failed to Time Out in Prescribed Time Limit.Caused by Stuck Operating Mechanism.Timers Exercised to Fee Mechanism | |
| 05000285/LER-1978-032, Forwards LER 78-032/03L-0 | Forwards LER 78-032/03L-0 | |
| 05000285/LER-1978-033, Forwards LER 78-033/03L-0 | Forwards LER 78-033/03L-0 | |
| 05000285/LER-1978-033-03, /03L-0 on 781014:Reactor Coolant Cold Leg Temp Indicator B/122C Failed High Off Scale Because of an Open Circuited Rosemount Model 104VC Rtd.The RTD Will Be Replaced During Present Refueling Outage | /03L-0 on 781014:Reactor Coolant Cold Leg Temp Indicator B/122C Failed High Off Scale Because of an Open Circuited Rosemount Model 104VC Rtd.The RTD Will Be Replaced During Present Refueling Outage | |
| 05000285/LER-1978-034-03, /03L-0 on 781026:repeated Tripping of Stack Particulate Process Monitor.Caused by Trip Set in Accordance W/Tech Specs Table 2-1 at 9.6x10-2,rather than More Conservative Release Rates 2x10-3 | /03L-0 on 781026:repeated Tripping of Stack Particulate Process Monitor.Caused by Trip Set in Accordance W/Tech Specs Table 2-1 at 9.6x10-2,rather than More Conservative Release Rates 2x10-3 | |
| 05000285/LER-1978-034, Forwards LER 78-034/03L-0 | Forwards LER 78-034/03L-0 | |
| 05000285/LER-1978-035-03, /03L-0 on 781113:during Test of Ventilation Isolation Actuation Signal,Lockout 86B1/VIAS Did Not Trip. Cause Unidentified,Since Relay Retested & Found to Be Operating Normally.Relays Will Continue to Be Tested | /03L-0 on 781113:during Test of Ventilation Isolation Actuation Signal,Lockout 86B1/VIAS Did Not Trip. Cause Unidentified,Since Relay Retested & Found to Be Operating Normally.Relays Will Continue to Be Tested | |
| 05000285/LER-1978-035, Forwards LER 78-035/03L-0 | Forwards LER 78-035/03L-0 | |
| 05000285/LER-1978-036-03, /03L-0 on 781101:auxiliary Feedwater Check Valve FW-164 Found to Be Oriented in Wrong Position.Caused by Missing Valve Disk Plate Which Was Subsequently Located & Recovered | /03L-0 on 781101:auxiliary Feedwater Check Valve FW-164 Found to Be Oriented in Wrong Position.Caused by Missing Valve Disk Plate Which Was Subsequently Located & Recovered | |
| 05000285/LER-1978-036, Forwards LER 78-036/03L-0 | Forwards LER 78-036/03L-0 | |
| 05000285/LER-1978-037, Forwards LER 78-037/03L-0 | Forwards LER 78-037/03L-0 | |
| 05000285/LER-1978-037-03, /03L-0 on 781116:during Refueling,All Limitorque Valves Were Inspec for Proper Staking of the Lock Nut on the Motor operator.30 of 65 Valves Exhibited Unstaked Lock Nuts.Lock Nuts Were Staked IAW Manufacturers Instructions | /03L-0 on 781116:during Refueling,All Limitorque Valves Were Inspec for Proper Staking of the Lock Nut on the Motor operator.30 of 65 Valves Exhibited Unstaked Lock Nuts.Lock Nuts Were Staked IAW Manufacturers Instructions | |
| 05000285/LER-1978-038-01, /01T-0 on 781127:Diesel Generator 2 Failed to Auto Close Onto the Bus;Breaker Mode Switch Contracts 27-27c Failed to Make Contact.Caused by Contact Failure | /01T-0 on 781127:Diesel Generator 2 Failed to Auto Close Onto the Bus;Breaker Mode Switch Contracts 27-27c Failed to Make Contact.Caused by Contact Failure | |
| 05000285/LER-1978-038, Forwards LER 78-038/01T-0 | Forwards LER 78-038/01T-0 | |
| 05000285/LER-1978-039, Forwards LER 78-039/03L-0 | Forwards LER 78-039/03L-0 | |
| 05000285/LER-1978-039-03, /03L-0 on 781122:noted That Level Transmiter for C Channel (C/LT-901) for Steam Generator RC-2A Level Instrumentation Not W/In Specs.Caused by Calibr Drift of Ge/Mac Model 555 Transmitter | /03L-0 on 781122:noted That Level Transmiter for C Channel (C/LT-901) for Steam Generator RC-2A Level Instrumentation Not W/In Specs.Caused by Calibr Drift of Ge/Mac Model 555 Transmitter | |
| 05000285/LER-1978-040-03, /03L-1 on 781205:during 1978 Refueling Outage, Containment Leak Rate Exceeded Limits.Penetrations Were Repaired & Leakage Was Reduced to Below Limits | /03L-1 on 781205:during 1978 Refueling Outage, Containment Leak Rate Exceeded Limits.Penetrations Were Repaired & Leakage Was Reduced to Below Limits | |
| 05000285/LER-1978-040, Forwards LER 78-040/03L-0 | Forwards LER 78-040/03L-0 | |
| 05000285/LER-1978-041, Forwards LER 78-041/03L-0 | Forwards LER 78-041/03L-0 | |
| 05000285/LER-1978-041-03, /03L-0 on 781207:air Flow Rate Through Charcoal Filter Units VA-26A,VA-26B & VA-66 Found to Be Less than Tech Specs.Cause Undetermined;Investigation Is Currently Proceeding | /03L-0 on 781207:air Flow Rate Through Charcoal Filter Units VA-26A,VA-26B & VA-66 Found to Be Less than Tech Specs.Cause Undetermined;Investigation Is Currently Proceeding | |
| 05000285/LER-1978-042, Forwards LER 78-042/03L-0 | Forwards LER 78-042/03L-0 | |
| 05000285/LER-1978-042-03, /03L-0 on 781124:during Shutdown Cooling Interlock Test Noted That PC-105B Was Not Operating.Caused by Valve Closing Relay 94-347/348 Not Being Wired to PC-105B; Inadvertently Disconnected in 1977 | /03L-0 on 781124:during Shutdown Cooling Interlock Test Noted That PC-105B Was Not Operating.Caused by Valve Closing Relay 94-347/348 Not Being Wired to PC-105B; Inadvertently Disconnected in 1977 | |
| 05000285/LER-1978-043, Forwards LER 78-043/03L-0 | Forwards LER 78-043/03L-0 | |
| 05000285/LER-1978-043-03, /03L-0 on 781204:during Inspec of Discharged Fuel Assemblies,A Single Fuel Pin Was Observed to Have Failed, Assoc W/Manufacture & Exposure of Present Day Nuc Fuel | /03L-0 on 781204:during Inspec of Discharged Fuel Assemblies,A Single Fuel Pin Was Observed to Have Failed, Assoc W/Manufacture & Exposure of Present Day Nuc Fuel | |
| 05000285/LER-1978-044-03, /03L-0 on 781214:during 1978 Refueling Outage, Certain Surveillance Tests Req by Tech Specs Could Not Be Performed Because of Shutdown Condition.Facil Lic Change 77-11 Submitted to NRC on 781109 to Delete Requirements | /03L-0 on 781214:during 1978 Refueling Outage, Certain Surveillance Tests Req by Tech Specs Could Not Be Performed Because of Shutdown Condition.Facil Lic Change 77-11 Submitted to NRC on 781109 to Delete Requirements | |
| 05000285/LER-1978-044, Forwards LER 78-044/03L-0 | Forwards LER 78-044/03L-0 | |
| 05000285/LER-1978-045, Forwards LER 78-045/01T-0 | Forwards LER 78-045/01T-0 | |
| 05000285/LER-1978-045-01, /01T-0 on 781220:during Plant heatup,1 Pressure Channel for Power Operated Relief Valve (PORV) Sys Was Responding.Operator Pulled Recorder Fuses Causing PORV Valves to Open,Then Closed Them to Terminate Transient | /01T-0 on 781220:during Plant heatup,1 Pressure Channel for Power Operated Relief Valve (PORV) Sys Was Responding.Operator Pulled Recorder Fuses Causing PORV Valves to Open,Then Closed Them to Terminate Transient | |
| 05000285/LER-1978-046, Forwards LER 78-046/03L-0 | Forwards LER 78-046/03L-0 | |
| 05000285/LER-1978-046-03, /03L-0 on 781227:during Operation,A Small Leak Developed at Weld on Charging Pump CH-1A Connection to Demineralized Water Line.Caused by Vibration of Piping in Svc.Crack Was Ground Out & Rewelded | /03L-0 on 781227:during Operation,A Small Leak Developed at Weld on Charging Pump CH-1A Connection to Demineralized Water Line.Caused by Vibration of Piping in Svc.Crack Was Ground Out & Rewelded | |