- 05000424/LER-1994-004-02, :on 940619,discovered That Filtration Heaters for Three of Four Trains of CREFS Were Deenergized.Caused by Power Disturbance to Plant Electrical Systems.Heaters Were Reset & Restored to Full Capability + (ML20070F349)
- 05000275/LER-1982-011-03, /03L-0:on 821024,steam Generator Blowdown Effluent Line Flow Rate Measurement Device FR-53 Found Inoperable Prior to Fuel Load.Caused by Worn Motor Gear Assembly. Design Change Will Correct Erroneous Readings + (ML20070F350)
- ML20070F351 + (ML20070F351)
- ML20070F358 + (ML20070F358)
- ML20070F373 + (ML20070F373)
- ML20070F376 + (ML20070F376)
- ML20070F378 + (ML20070F378)
- ML20070F383 + (ML20070F383)
- ML20070F384 + (ML20070F384)
- RBG-13-944, Final Deficiency Rept DR-68 Re Application of non-specified Preservative (Tectyl 506) on High Pressure Core Spray Diesel Engine Pistons & Valve Mechanisms.Initially Reported on 821122.All Tectyl 506 to Be Removed + (ML20070F401)
- 05000338/LER-1982-073, Forwards LER 82-073/03L-0 + (ML20070F404)
- FVY-82-131, Responds to 821104 Request for Addl Info Re Adequacy of Station Electrical Distribution Sys Voltages.Proposed Change to Tech Specs Not Warranted Since Transformer Operability Already Covered by Existing Tech Specs + (ML20070F409)
- 05000414/LER-1994-002-05, :on 940615,unit 2 Rtbs Were Manually Opened Due to Intermittent Component Failure of Rod Control System Group C Firing Card.Cro Inserted All Rods Upon Discovery of One Group of Rods within Different Banks + (ML20070F423)
- 05000369/LER-1982-078, Forwards LER 82-078/03L-0 + (ML20070F430)
- 05000338/LER-1982-073-03, /03L-0:on 821118,B Reactor Trip Breaker Failed to Auto Open on Simulated Reactor Signal.Caused by Stuck Undervoltage Tripping Mechanism.Device Removed,Cleaned, Lubricated & Reinstalled + (ML20070F433)
- ML20070F439 + (ML20070F439)
- 1CAN029105, Responds to NRC Bulletin 89-002 Re Stress Corrosion Cracking of high-hardness,stainless Steel Preloaded Bolting in Anchor/Darling Swing Check Valves.No Indications of Cracking or Broken Bolts Noted During Insp of Valves + (ML20070F440)
- 05000293/LER-1982-053, Forwards LER 82-053/03L-0 + (ML20070F441)
- 05000325/LER-1982-119, Forwards LER 82-119/03L-0 + (ML20070F447)
- 05000293/LER-1982-053-03, /03L-0:on 821110,ground Fault Alarm Observed on 125-volt Dc Battery Circuit & Traced to Limit Switch Circuitry for MOV2301-3.Caused by Valve Packing Steam Leakage.Packing Tightened for short-term Fix + (ML20070F452)
- 05000369/LER-1982-078-03, /03L-0:on 821108,during Draining of Rcs,Both Centrifugal Charging Pumps Inoperable.Caused by Confusing Statement in Draining Procedure Allowing Both Breakers to Be Racked Out & Tagged.Procedure Revised & Personnel Counseled + (ML20070F455)
- 0CAN029111, Occupational Exposure Data Rept - 1990 + (ML20070F456)
- ML20070F458 + (ML20070F458)
- ML20070F461 + (ML20070F461)
- ML20070F463 + (ML20070F463)
- 05000237/LER-1982-047, Forwards LER 82-047/03L-0 + (ML20070F465)
- ML20070F467 + (ML20070F467)
- 05000336/LER-1994-021-01, :on 940615,determined That Shielding Had Been Installed Without Processing Temporary Shielding Request.Caused by Bricks Installed W/Inadequate Controls & Methods.Shielding Was Removed + (ML20070F474)
- 05000237/LER-1982-047-03, /03L-0:on 821117,while Performing Dis 5003,reactor Vessel Low Water Level ECCS Initiation,Lis 263-72A Found Set at 111.6 Inches Delta P.Caused by Defective Procedure.Lis 263-72A Reset & Setpoints Revised + (ML20070F477)
- ML20070F484 + (ML20070F484)
- 05000368/LER-1991-005, :on 910201,automatic Reactor Trip Initiated by Core Protection Calculators.Caused by Faulty Racking Motor. Racking Motor Removed from Svc & Inspected,Design Engineering Reviewed & Enhanced Sys Design + (ML20070F485)
- 05000338/LER-1982-077, Forwards LER 82-077/03L-0 + (ML20070F489)
- RBG-34552, Discusses Concern W/Configuration of Automatic Start Signal for Main Control Room Area Ventilation Sys in Emergency Mode of Operations,Identified on 910212.One Charcoal Filter Train Placed in Continuous Operation + (ML20070F493)
- ML20070F504 + (ML20070F504)
- 05000313/LER-1982-024, Forwards LER 82-024/03L-0 + (ML20070F505)
- ML20070F511 + (ML20070F511)
- ML20070F515 + (ML20070F515)
- RBG-34553, Requests That New Date of Submittal of plant-specific Hydrogen Control Final Analysis Be within 6 Months of Hydrogen Control Owners Group Accepted Topical Rept + (ML20070F520)
- 05000313/LER-1982-024-03, /03L-0:on 821104,at 68% Power,Control Rod Drive B Ac Breaker Failed to Trip.Caused by Latch Adjusting Screw Being Improperly Adjusted.Breaker Replaced + (ML20070F521)
- ML20070F524 + (ML20070F524)
- 05000361/LER-1991-001-01, :on 910125,post-accident Cleanup Unit Inlet Duct Heater Found in Off Position,Resulting in Deenergization of Heater.From 910119-22,operability of Heater Pilot Switch Not Satisfied + (ML20070F528)
- 05000338/LER-1982-077-03, /03L-0:on 821119,MOV-1536 Could Not Be Opened After Period Test.Caused by Loose Control Cable Connection at Motor Operator.Loose Connection Tightened + (ML20070F530)
- ML20070F535 + (ML20070F535)
- ML20070F537 + (ML20070F537)
- ML20070F538 + (ML20070F538)
- ML20070F541 + (ML20070F541)
- 05000335/LER-1982-057, Forwards LER 82-057/03L-0 + (ML20070F544)
- RBG-13-927, Interim Deficiency Rept Re Violation of Requirements for Min Spacing Between Drills in Anchors & Adjacent Embedment Plates.Initially Reported on 821109.Investigation Re Reporting Criteria Continuing.Next Rept Expected by 830127 + (ML20070F549)
- ML20070F555 + (ML20070F555)
- 05000416/LER-1982-063-99, /99X-1:on 820902,during Shutdown,Several fire- Rated Cable Penetration Seals Were Broken on Field Termination Cabinets in Control Room to Allow Routing of Addl Cable.Seals Repaired Following Maint Activities + (ML20070F564)
- IR 05000344/1982006 + (ML20070F570)