ML20070F485  +
05000368  +  and 00368  +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
05000368/LER-1991-005, :on 910201,automatic Reactor Trip Initiated by Core Protection Calculators.Caused by Faulty Racking Motor. Racking Motor Removed from Svc & Inspected,Design Engineering Reviewed & Enhanced Sys Design +, 05000368/LER-1991-005, :on 910201,automatic Reactor Trip Initiated by Core Protection Calculators.Caused by Faulty Racking Motor. Racking Motor Removed from Svc & Inspected,Design Engineering Reviewed & Enhanced Sys Design +, 05000368/LER-1991-005, :on 910201,automatic Reactor Trip Initiated by Core Protection Calculators.Caused by Faulty Racking Motor. Racking Motor Removed from Svc & Inspected,Design Engineering Reviewed & Enhanced Sys Design +, 05000368/LER-1991-005, :on 910201,automatic Reactor Trip Initiated by Core Protection Calculators.Caused by Faulty Racking Motor. Racking Motor Removed from Svc & Inspected,Design Engineering Reviewed & Enhanced Sys Design +, 05000368/LER-1991-005, :on 910201,automatic Reactor Trip Initiated by Core Protection Calculators.Caused by Faulty Racking Motor. Racking Motor Removed from Svc & Inspected,Design Engineering Reviewed & Enhanced Sys Design +, 05000368/LER-1991-005, :on 910201,automatic Reactor Trip Initiated by Core Protection Calculators.Caused by Faulty Racking Motor. Racking Motor Removed from Svc & Inspected,Design Engineering Reviewed & Enhanced Sys Design +, 05000368/LER-1991-005, :on 910201,automatic Reactor Trip Initiated by Core Protection Calculators.Caused by Faulty Racking Motor. Racking Motor Removed from Svc & Inspected,Design Engineering Reviewed & Enhanced Sys Design +, 05000368/LER-1991-005, :on 910201,automatic Reactor Trip Initiated by Core Protection Calculators.Caused by Faulty Racking Motor. Racking Motor Removed from Svc & Inspected,Design Engineering Reviewed & Enhanced Sys Design +, 05000368/LER-1991-005, :on 910201,automatic Reactor Trip Initiated by Core Protection Calculators.Caused by Faulty Racking Motor. Racking Motor Removed from Svc & Inspected,Design Engineering Reviewed & Enhanced Sys Design +, 05000368/LER-1991-005, :on 910201,automatic Reactor Trip Initiated by Core Protection Calculators.Caused by Faulty Racking Motor. Racking Motor Removed from Svc & Inspected,Design Engineering Reviewed & Enhanced Sys Design +, 05000368/LER-1991-005, :on 910201,automatic Reactor Trip Initiated by Core Protection Calculators.Caused by Faulty Racking Motor. Racking Motor Removed from Svc & Inspected,Design Engineering Reviewed & Enhanced Sys Design +, 05000368/LER-1991-005, :on 910201,automatic Reactor Trip Initiated by Core Protection Calculators.Caused by Faulty Racking Motor. Racking Motor Removed from Svc & Inspected,Design Engineering Reviewed & Enhanced Sys Design +, 05000368/LER-1991-005, :on 910201,automatic Reactor Trip Initiated by Core Protection Calculators.Caused by Faulty Racking Motor. Racking Motor Removed from Svc & Inspected,Design Engineering Reviewed & Enhanced Sys Design +, 05000368/LER-1991-005, :on 910201,automatic Reactor Trip Initiated by Core Protection Calculators.Caused by Faulty Racking Motor. Racking Motor Removed from Svc & Inspected,Design Engineering Reviewed & Enhanced Sys Design +, 05000368/LER-1991-005, :on 910201,automatic Reactor Trip Initiated by Core Protection Calculators.Caused by Faulty Racking Motor. Racking Motor Removed from Svc & Inspected,Design Engineering Reviewed & Enhanced Sys Design +, 05000368/LER-1991-005, :on 910201,automatic Reactor Trip Initiated by Core Protection Calculators.Caused by Faulty Racking Motor. Racking Motor Removed from Svc & Inspected,Design Engineering Reviewed & Enhanced Sys Design +, 05000368/LER-1991-005, :on 910201,automatic Reactor Trip Initiated by Core Protection Calculators.Caused by Faulty Racking Motor. Racking Motor Removed from Svc & Inspected,Design Engineering Reviewed & Enhanced Sys Design +, 05000368/LER-1991-005, :on 910201,automatic Reactor Trip Initiated by Core Protection Calculators.Caused by Faulty Racking Motor. Racking Motor Removed from Svc & Inspected,Design Engineering Reviewed & Enhanced Sys Design +, 05000368/LER-1991-005, :on 910201,automatic Reactor Trip Initiated by Core Protection Calculators.Caused by Faulty Racking Motor. Racking Motor Removed from Svc & Inspected,Design Engineering Reviewed & Enhanced Sys Design +, 05000368/LER-1991-005, :on 910201,automatic Reactor Trip Initiated by Core Protection Calculators.Caused by Faulty Racking Motor. Racking Motor Removed from Svc & Inspected,Design Engineering Reviewed & Enhanced Sys Design +  and 05000368/LER-1991-005, :on 910201,automatic Reactor Trip Initiated by Core Protection Calculators.Caused by Faulty Racking Motor. Racking Motor Removed from Svc & Inspected,Design Engineering Reviewed & Enhanced Sys Design +
0.0199 d (0.478 hours, 0.00285 weeks, 6.55221e-4 months)  +
March 4, 1991  +
1,991  +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
14:44:25, 16 December 2024  +
2P-32B +  and 2P-3B +
March 4, 1991  +
:on 910201,automatic Reactor Trip Initiated by Core Protection Calculators.Caused by Faulty Racking Motor. Racking Motor Removed from Svc & Inspected,Design Engineering Reviewed & Enhanced Sys Design   +