- PY-CEI-NRR-1293, Forwards Clarification of Two Issues Discussed in 901214 Response to Violation Noted in Insp Rept 50-440/90-12,per 910108 Telcon + (ML20067C818)
- ML20067C819 + (ML20067C819)
- ML20067C821 + (ML20067C821)
- BSEP-82-2734, Forwards Monthly Operating Repts for Nov 1982 + (ML20067C822)
- ML20067C823 + (ML20067C823)
- ML20067C828 + (ML20067C828)
- ML20067C832 + (ML20067C832)
- ML20067C835 + (ML20067C835)
- ML20067C845 + (ML20067C845)
- ML20067C849 + (ML20067C849)
- 05000458/LER-1990-048, :on 901224,EQ Operability Status of Two H Ingniters Apparently Exceeded Lifetimes.Caused by Temps Higher than Originally Used to Calculate Lifetimes.Six H Igniters & Associated Cables Replaced + (ML20067C850)
- ML20067C851 + (ML20067C851)
- ML20067C854 + (ML20067C854)
- ML20067C855 + (ML20067C855)
- ML20067C856 + (ML20067C856)
- 05000373/LER-1994-004, Forwards LER 94-004-00 Re Control Rod Position Indication Sys Failure on 940105.Although Event Occurred on 940105, Reportability Requirement Under 10CFR50.73 Not Recognized Until 940203 + (ML20067C863)
- ML20067C865 + (ML20067C865)
- 05000443/LER-1994-001, :on 940125,reactor Trip & Safety Injection Occurred Due to Inadvertent MSIV Closure.Caused by Contaminated Hydraulic Fluid,Sticking Main Dump Valve & Related Hardware Issues + (ML20067C868)
- 05000265/LER-1994-001, Forwards LER 94-001-00.IST Procedures Revised to Incorporate Interim Procedure Requirements & RCIC Pump Tested Using Revised Procedures + (ML20067C871)
- 05000265/LER-1994-001-03, :on 940216,RCIC Failed to Meet TS Flow & Pressure Requirements.Caused by Increased Clearances Between Pump Shaft Throttle Sleeve & Throttle Bushing & Wear Rings Reducing Margin of Performance.Rotating Element Replaced + (ML20067C875)
- 05000373/LER-1994-004-01, :on 940105,CRPI Sys Failed Due to Card Failure. Notice of Enforcement Discretion Requested & Granted Not to Enforce Compliance W/Ts 3.1.3.7 for Period of 6 Addl H & on 940105,RPIS Declared Operable Following Repair & Testing + (ML20067C879)
- 05000325/LER-1994-004, :on 940126,loss of RPS a Bus Power & Associated ESF Actuations Occurred.Caused by Operator Error.Reviewed Event W/Involved Operator + (ML20067C880)
- 05000366/LER-1980-141, Forwards Updated LER 80-141/03X-1 + (ML20067C881)
- 05000254/LER-1994-001-04, :on 940102,inadvertent Insertion of Control Rod H-1 from Position 48 to 14 Occurred During Instrument Maint Surveillance.Cause Not Determined.Crd H-1 Inserted Into Position 00 & HCU Rebuilt + (ML20067C883)
- ML20067C888 + (ML20067C888)
- ML20067C889 + (ML20067C889)
- ML20067C895 + (ML20067C895)
- ML20067C897 + (ML20067C897)
- ML20067C899 + (ML20067C899)
- 05000498/LER-1994-002-01, :on 940115,centifugal Charging Pump 1A Discharge Bypass Valve Found in Open Position Contrary to TS 3.1.2.3 Requirements.Caused by hydro-pneumatic Transient. MOV Database Searched + (ML20067C902)
- ML20067C903 + (ML20067C903)
- ML20067C907 + (ML20067C907)
- ML20067C908 + (ML20067C908)
- ML20067C911 + (ML20067C911)
- ML20067C914 + (ML20067C914)
- ML20067C917 + (ML20067C917)
- B14750, Provides NRC W/Addl Info on Hydrogen Monitor Variable for Reg Guide 1.97,Rev 2 for Unit 2 + (ML20067C924)
- 05000366/LER-1980-141-03, While Making Power Changes from 2,180 to 1,980 MWt,N004 HPCI Steam Line Dp Switch Found to Actuate at 198 Inches Water.Caused by Setpoint Drift.Switch Recalibr + (ML20067C925)
- ML20067C926 + (ML20067C926)
- ML20067C927 + (ML20067C927)
- ML20067C930 + (ML20067C930)
- 05000346/LER-1982-058, Forwards LER 82-058/03L-0 + (ML20067C931)
- 05000366/LER-1980-103, Forwards Updated LER 80-103/01X-1 + (ML20067C934)
- NRC-91-0005, Revises Commitment in Response to Violations Noted in Insp Rept 50-341/86-11.Delinquent Findings Rept No Longer Necessary Based on Performance History for 1990 & 1991 Which Indicates Less than One Finding Per Month + (ML20067C936)
- ML20067C938 + (ML20067C938)
- 05000366/LER-1980-103-01, At 97% Power,High Drywell Pressure Switches N010A - D Actuated at 2.21,2.34,2.27 & 2.47 Psig,Respectively;Above Tech Spec Limit of Plus/Minus 2 Psig.Caused by Setpoint Drift.Switches Recalibr & Tested + (ML20067C939)
- ML20067C940 + (ML20067C940)
- ML20067C941 + (ML20067C941)
- ML20067C942 + (ML20067C942)
- 05000346/LER-1982-058-03, /03L-0:on 821106,while Performing ST 5032.01, Setpoints for Containment post-accident Radiation Monitor Re 4597BA Found Drifted,Rendering Monitor Inoperable. Caused by Component Failure.Microprocessor Boards Replaced + (ML20067C943)
- ML20067C946 + (ML20067C946)