List of results
- ML20067C665 + (ML20067C665)
- ML20067C672 + (ML20067C672)
- 05000301/LER-1982-009, Forwards LER 82-009/01T-0 + (ML20067C687)
- ML20067C697 + (ML20067C697)
- 05000301/LER-1982-009-01, /01T-0:on 821122,axial Flux Differential Monitoring Program & Alarm Found Inadvertently Halted from 821120-22 W/O Manually Logging Flux Differential.Caused by Operator Diagnosing Backup Computer Problem + (ML20067C700)
- 05000237/LER-1982-046, Forwards LER 82-046/03L-0 + (ML20067C713)
- 05000237/LER-1982-046-03, /03L-0:on 821109,during Normal Operation,High Range Boron Test for Standby Liquid Control,Dcp 1100-4, Revealed Boron Concentration Below Tech Specs.Caused by Inadequate Procedure for Sys Leakage.Procedure Revised + (ML20067C719)
- ML20067C723 + (ML20067C723)
- 05000250/LER-1982-015, Forwards LER 82-015/03L-0 + (ML20067C727)
- ML20067C729 + (ML20067C729)
- 05000250/LER-1982-015-03, /03L-0:on 821104,during Normal operation,3A High Head Safety Injection Pump Failed to Start from Manual Operation.Cause Undetermined.Pump Breaker Racked Out & Back In.Repairs Made to Breaker + (ML20067C733)
- ML20067C734 + (ML20067C734)
- 05000352/LER-1991-001-01, :on 910107,3 of 4 Reactor Encl HVAC Supply & Exhaust Air Fans Tripped,Resulting in High Positive Air Pressure.Plant Shutdown on 910108.Caused by Failure of Discharge Dampers to Open Fully.Coil Replaced + (ML20067C736)
- ML20067C740 + (ML20067C740)
- ML20067C741 + (ML20067C741)
- ML20067C743 + (ML20067C743)
- ML20067C744 + (ML20067C744)
- ML20067C745 + (ML20067C745)
- ML20067C753 + (ML20067C753)
- 05000425/LER-1994-003, :on 940127,PEO Mistakenly Measured Temp in Two Different Areas of Room A009,rather than Taking Separate Mesurements in Rooms A009 & A008.Caused by Personnel Error. PEO Coached & Reminded of Importance to Detail + (ML20067C756)
- HL-4509, Responds to NRC Re Violations Noted in Insp Repts 50-321/93-27 & 50-336/93-27.Corrective Actions:Default Flow Rate Values Used in SPDS Reactor Bldg Stacks Revised & Effects of Inaccurate Flow Rates on Effluents Evaluated + (ML20067C763)
- ML20067C764 + (ML20067C764)
- ML20067C768 + (ML20067C768)
- ML20067C774 + (ML20067C774)
- 05000346/LER-1982-056, Forwards LER 82-056/03L-0 + (ML20067C777)
- ML20067C778 + (ML20067C778)
- ML20067C779 + (ML20067C779)
- ML20067C784 + (ML20067C784)
- ML20067C785 + (ML20067C785)
- 05000361/LER-1994-012, :on 940126,inadequacies in Electrical Distribution Sys Design Calculations.Caused by Incorrect Engineering Judgement.C/A:Upgraded MCC Control Circuit for 2HV9303 by Replacing Transformer + (ML20067C787)
- ML20067C790 + (ML20067C790)
- ML20067C792 + (ML20067C792)
- ML20067C795 + (ML20067C795)
- 05000346/LER-1982-056-03, /03L-0:on 821104,breaker BF114 Tripped,Causing Loss of Power to F12 Series Motor Control Ctrs.Caused by Ground in Jockey Fire Pump Motor When Pump Seized.Pump Rebuilt & Motor Replaced + (ML20067C797)
- ML20067C800 + (ML20067C800)
- ML20067C801 + (ML20067C801)
- ML20067C803 + (ML20067C803)
- ML20067C807 + (ML20067C807)
- B14713, Nonproprietary Version of Response to NRC Questions on RCS Flow Reduction Evaluation + (ML20067C809)
- RBG-13-665, Responds to NRC 820708 & 0929 Ltrs Re Violations Noted in IE Insp Rept 50-458/82-03.Corrective Actions:Pipe Supports Designed Per ASME Code Requirements + (ML20067C813)
- JSP-062-94, Responds to 931227 RAI Re GL-92-08, Thermo-Lag 330-1 Fire Barriers + (ML20067C814)
- RBG-40146, Responds to Violation Noted in Insp Rept 50-458/93-28 Re Failure to Implement Corrective Actions Which Allowed Entry by Plant Into Condition Prohibited by Ts.Work Control Process Refined to Prevent Nonscheduled Work or Testing + (ML20067C816)
- PY-CEI-NRR-1293, Forwards Clarification of Two Issues Discussed in 901214 Response to Violation Noted in Insp Rept 50-440/90-12,per 910108 Telcon + (ML20067C818)
- ML20067C819 + (ML20067C819)
- ML20067C821 + (ML20067C821)
- BSEP-82-2734, Forwards Monthly Operating Repts for Nov 1982 + (ML20067C822)
- ML20067C823 + (ML20067C823)
- ML20067C828 + (ML20067C828)
- ML20067C832 + (ML20067C832)
- ML20067C835 + (ML20067C835)
- ML20067C845 + (ML20067C845)