Forwards Semiannual Update of Ninth Edition of Integrated Implementation Schedule for San Onofre Nuclear Generating Station Units 2 & 3
ML20067C774
Person / Time
Site: San Onofre  
Issue date: 02/23/1994
From: Marsh W
SOUTHERN CALIFORNIA EDISON CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
NUDOCS 9403040155
Download: ML20067C774 (20)


Text

. -.

j

_f*"$$?

Southern Califomia Edison Company 23 PARKEH STHEET IHVINE, CALIFOHNIA 92718 i

February 23, 1994 j

WALTER C. MAHSH m,,_

MANAGf H OF NVCLE.AH MEQULA TORY AFF AlHS (7 0 4) 464 44(r.3 U. S. Nuclear Regulatory Commission Attention: Document Control Desk i

j Washington, D. C.

20555 Gentlemen:

Subject:

Docket Nos. 50-361 and 50-362 Ninth Edition of.the Integrated Implementation Schedule (IIS)

San Onofre Nuclear Generating Station Units 2 and 3

Reference:

1.

Letter from W. C. Marsh (SCE) to Document Control Desk (NRC), dated July 2, 1993; Eighth Edition of the Integrated Implementation Schedule (IIS).

2.

Letter from F. R. Handy (SCE) to Document Control Desk i

(NRC),DatedJune 18, 1990; Detailed Control Room Design Review Modifications, San Onofre Nuclear Generating Station l

Units 2 and 3.

Enclosures 1 through 5 provide the semi-annual update of the' Ninth Edition of the Integrated Implementation Schedule.(IIS) for the San Onofre Nuclear l

Generating Station (SONGS), Units 2 and 3. lists the Schedule A, l

B, and C projects for SONGS 2 and 3, completed during the recent Cycle 7 outages. lists the Cycle 7 non-outage work.

Enclosures 3 and 4 list by outage, the Schedule A, 8, and C projects for SONGS 2 and 3, respectively. lists the ongoing evaluations for major issues for SONGS 2 and 3.

A comparison to the Eighth Edition of the IIS (referenced) reveals that the following changes have occurred to the Cycle 8 schedules:

ACTION UNIT CYCLE SCHEDULE MODIFICATION Added 2/3 8

C In-containment PAMI Improvements (DCP 2005)

Added 2/3 8

C Snubber Reduction - ongoing program (DCP 6683.04)

Added 2/3 8

C Ladders and Platforms - Non-outage, on-going program (DCP 6735.03)

Added 2/3 8

C RCS Vacuum Fill (DCP 6941)

Added 2/3 8

.C AVRReplacement(DCP6946)

I f

00 o

9403040155 940223 d

s PDR ADOCK 05000361 i

P PDR n

l

i Document Control Desk Added 2/3 8

C Ex-Core Neutron Detectors (DCP 6984)

Added 2/3 8

C Reorient / Replace CCW Containment Isolation Valve (DCP 6986.00)

Added 2/3 8

B Addition of Valves and Drains for IST in accordance with Generic Letter 89-04 (DCP 6988)

Added 2/3 8

C RCP Design Changes (DCP 6990.00)

Added 2/3 8

B Intake Structure Security Barriers (SCE to NRC letters February 12, 1993 and July 15, 1993) (DCP 6999.00)

Added 2/3 8

C Containment Purge and Plant Vent Stack Radiation Monitor (DCP 6876)

Deleted 2/3 8

C Replace sodium and chloride analyzers (DCP 6884)

Deleted 2/3 8

C Replace pil Instrumentation (DCP 6886)

Scope 2/3 8

C Replace TPSS Secondary Chemistry Change Instrumentation (DCP 6885)

Added 2/3 8

C Replace HP1000 Computer and Meteorological Environment Enclosure (DCP 7032)

Added 2

8 C

Replace HFMUD Chemistry Analyzers (DCP 7034)

Added 2/3 8

B Target Rock solenoid valve upgrade in accordance with Generic Letter 91-15 (DCP6910)

Added 3

8 C

Seismic Joint Repair (DCP 6977)

Added 2

8 C

Talega #2 Transmission Line (DCP 2062)

Deleted 2/3 8

C Add Permanent Breathing Air and Communication Stations to Steam Genera *-

P1atform (DCP 6809)

Deleted 2/3 8

C Replace Refueling Cavity Seals (DCP 6857)

Deleted 2/3 8

C Redesign Blowdown Drain System (DCP 6752)

Moved from 2 8

C TGISInstrumentReplacement(DCP6933)

V3

)

i l

\\

j l

Document Control Desk Added 2

8 C

Degraded Grid Voltage (DCP 2060) 1 i

Sched 2/3 8

C Install Removable Di Controls (DCP 6855) gital Polar Crane l

Change Added 2/3 8

C CRA 44 Card Replacement (DCP 6908)

Added 2/3 8

C T-121 Nitrogen Blanket System (DCP 6877)

The Detailed Control Room Design Review Modifications noted in Reference 2 (DCP 6609) were completed during the SONGS 2 and 3 Cycle 7 refueling outages.

l l

The outage related portions of DCP 6605.09, CR 61 Panel Modifications, have l

been completed and the non-outage portions will be completed by 4/29/94 (i.e.,

i during the first 120 days of Unit 3 Cycle 7 operation, as noted in i

Reference 1).

This work will complete the Human Engineering upgrades determined necessary by the Control Room Design Review evaluations as part of NUREG 0700.

l The safety related 480 VAC Load Center Transformers for Units 2 and 3 were replaced under DCP 6974.

The non-safety related transformers associated with this modification will be replaced during Cycle 8 and on a non-outage, as-needed basis.

This work has been moved from Schedule B to Schedule C.

The preliminary Cycle 9 scope of work is being developed.

It should be included in the Tenth Edition of the IIS.

DCP 6863.01, Pressurizer Vent Modification, was completed for Unit 2 during the Cycle 7 outage. However, this Schedule C work was deleted from the Unit 3 work scope for Cycle 7.

The Westinghouse Analytical Ranking Program (WARP) was not used to rank the relative safety significance of each Schedule A and B modification because their implementation schedules have been established in separate correspondence, if you have any questions on the Ninth Edition of the San Onofre Units 2 and 3 IIS, please let me know.

Very truly yours, h

M Enclosures

Document Control Desk cc:

K. E. Perkins, Jr., Acting Regional Administrator, NRC Region V J. A. Sloan, NRC Senior hesident Inspector, San Onofre Units 2 and 3 H. B. Fields, NRC Project Manager, San Onofre Units 2 and 3 l

l i

l

i l

l l

l 1

l l

i ENCLOSURE 1 1

WORK COMPLETED DURING THE SONGS 2 AND 3 i

l CYCLE 7 REFUELING OUTAGES l.

i l

I r

)

4 WORK COMPLETED DURING THE SONGS 2 CYCLE 7 REFUELING OUTAGE UNIT 2 CYCLE 7 SCHEDULE A - NRC RULE OR ORDER MODIFICATION REFERENCE LETTER / COMMENTS Station Blackout Modification 10CFR50.63 (DCP 6711)

UNIT 2 CYCLE 7 SCHEDULE B - REGULATORY COMMITHENT MODIFICATION REFERENCE LETTER / COMMENTS Control Room (CR) Annunciator NUREG 0700 (DCP 6609.00)

Rearrangement Modification CR 63 Annunciator Modifications NUREG 0700 (OCP 6609.02)

CR 63 Electrical Panel Modifications NUREG 0700 (DCP 6605.08)

Control Room Human Factors SCE letter to NRC dated-June 18, Modifications 1990 (DCP 6605.06)

Component Cooling Water (CCW) Seismic From SSFI and SCE letter to NRC Make-up Addition dated July.30, 1990 (DCP 6742.07)

Modify Plant Protection System (PPS)

LER 2-90-014, 3-89-007 (DCP 6827)

Test Switches Modify Overspeed Protection on Steam LER2-90-012,2-92-007(DCP6869)

Driven Auxiliary Feedwater Pumps Spill Prevention Control and H. Newton (SCE) letter to A. Coe Countermeasures Modification.

(Cal Regional. Water Quality Board) dated November 14, 1991 (DCP 6878) l l

1

Delete Cycling MSIS Relay; Provide LER 3-90-002-01 (DCP 6826)

Partial ESF Actuation Annunciator j

Steam Driven Auxiliary feedwater Pump LER 2-91-014 (DCP 6869)

Steam Supply Check Valve Modifications Load Center Transformer Replacements LER 2-92-008 (DCP 6974)

(SRportions) 1 Add T-hot and T-Cold Indicators to NUREG 0800 (DCP 6939)

Remote Shutdown Panel Inverter Room Temperature Alarm PRA to NRC (DCP 6831.01)

Equipment Hatch Backup Power NUMARC 91-06 Install Diesel Generator Turbocharger NRC IE Notice 85-32 (DCP 6754)

Prelube UNIT 2 CYCLE 7 SCHEDULE C - PLANT BETTERMENT MODIFICATION REFERENCE LETTER / COMMENTS Cross Connect Shutdown Cooling (DCP6863.00) and Containment Spray Systems Low Pressure Safety Injection (DCP6858)

Pump Seal Upgrades Add External Test Points to Plant (DCP6828)

Protection System (PPS) Panel Snubber Reduction (DCP6683.03)

Replace the Low Pressure Turbine (DCP6868)

Bellows with Stainless Steel Bellows Pressurizer Vent (DCP6863.01)

Install Cooler in Respiratory / Breathing (DCP6842)

Air System Remove MICDS Inside/0utside Containment (DCP6808.01)

Replace Flow Probe in the Plant (MMP6835)

Vent Stack Radiation Monitor 2

=

t WORK COMPLETED DURING THE SONGS 3 CYCLE 7 REFUELING OUTAGE UNIT 3 CYCLE 7 SCHEDULE A - NRC RULE OR ORDER MODIFICATION REFERENCE LETTER / COMMENTS l

Station Blackout Modification 10CFR50.63 (DCP 6711)

UNIT 3 CYCL.E 7 SCHEDULE B - REGULATORY COMMITMENT MODIFICATION REFERENCE LETTER / COMMENTS Control Room Annunciator NUREG 0700 (DCP 6609.00)

Rearrangement Modification CR 63 Annunciator Modifications NUREG0700(DCP6609.02)

CR 63 Electrical Panel Modifications NUREG 0700 (DCP 6605.08)

Control Room Human Factors Hodifications SCE letter to NRC dated June 18, 1990 (DCP 6605.06)

Component Cooling Water (CCW) Seismic From SSFI and SCE letter to NRC Hake-up Addition dated July 30, 1990 (DCP 6742.07)

Modify Plant Protection System (PPS)

LER2-90-014,3-89-007(DCP6827)

Test Switches Modify Overspeed Protection on Steam LER 2-90-012,'2-92-007 (DCP 6869)

Driven Auxiliary Feedwater Pumps Spill Prevention Control and H. Newton (SCE) letter to A. Coe Countermeasures Modification Cal RWQB dated November 14, 1991 DCP 6878 '.

Delete Cycling MSIS Relay; Provide LER 3-90-002-01 (DCP 6826)

Partial ESF Actuation Annunciator Steam Driven Auxiliary Feedwater Pump LER2-91-014(DCP6869)

Steam Supply Check Valve Modifications Add T-hot and T-cold Indicators to NUREG 0800 (DCP 6939)

Remote Shutdown Panel Load Center Transformer Replacements LER 2-92-008 (DCP 6974)

(SRportions)

Inverter Room Temperature Alarm PRA to NRC (DCP 6831.01)

Equipment Hatch Backup Power NUMARC 91-06 Install Diesel Generator NRC IE Notice 85-32 (DCP 6754)

Turbocharger Prelube 3

_ _ _. _ _ _.. ~. _ _ _ _,. -..

UNIT 3 CYCLE 7 SCHEDULE C - PLANT BETTERMENT MODIFICATION REFERENCE LETTER / COMMENTS Cross Connect Shutdown Cooling and (DCP6863.00)

Containment Spray Systems Low Pressure Safety Injection Pump (DCP6858)

Seal Upgrades Add External Test Points to Plant (DCP6828)

Protection System (PPS) Panel Snubber Reduction (DCP6683.03)

Replace Low Pressure Turbine Bellows (DCP 6868) with Stainless Steel Bellows Remove MICDS Inside/0utside Containment (DCP6808.01)

Replace Flow Probe in the Plant (MMP 6835)

Vent Stack Radiation Monitor 4

i l

l I

P J

ENCLOSURE 2 SONGS 2 AND 3 CYCLE 7 NON-0UTAGE WORK v,

.r-

SONGS 2 CYCLE 7 IKTEGRATED IMPLEMENTATION SCHEDULE d

NON-0UTAGE WORK UNIT 2 CYCLE 7 SCHEDULE B - REGULATORY COMMITMENT MODIFICATION REFERENCE LETTER / COMMENTS CR 61 Panel Modifications (DCP6605.09) d UNIT 2 CYCLE 7 SCHEDULE C - PLANT-BETTERMENT MODIFICATION REFERENCE LETTER / COMMENTS Turbine Building Sump Radiation Non-outage related modification (DCP Monitor Low Flow Alarms-6191)

Safety Injection System Pipe Vent (DCP6697)

Relocation Post Accident Sampling System (PASS)

(DCP 6751)

Skid Enhancements Modify PMS and COLSS Back-up Computer (DCP6716)

System

- Install Oxygen Monitor in the FFCPD Lab (MMP6891)

Modify 90-minute Emergency Control (DCP6888)

Room Lighting Battery Backup Ladders and Platforms (DCP6735.01) 4 1

4

--.a--

n, r-


m,m, r

,y.e

, - -,, e

i SONGS 3 CYCLE 7 INTEGRATED IMPLEMENTATION SCHEDULE NON-0UTAGE WORK UNIT 3 CYCLE 7 SCHEDULE B - REGULATORY COMMITMENT MODIFICATION REFERENCE LETTER / COMMENTS CR 61 Panel Modifications (DCP.6605,09)

UNIT 3 CYCLE 7 SCHEDULE C - PLANT BETTERMENT MODIFICATION REFERENCE LETTER /C0MMENTS Turbine Building Sump Radiation (DCP6191)

Monitor Low Flow Alarms-Replace Fire-and Security Computers (DCP7018)

Temporary Facility Modification (DCP 6748)

Incorporations Modify PMS and COLSS Back-up Computer (DCP6716)

System Install Oxygen Monitor in the FFCPD Lab

-(MMP 6891)-

Ladders and Platforms (DCP6735.01)

Modify 90-minute Emergency Control (DCP 6888)

Room Lighting Battery Backup 2

i

~

.,n..,

~,..-- -..

i e

I i

{

i i

1 I

I f

ENCLOSURE 3 l

SONGS 2 CYCLE 8 SCHEDULES i

t l

i SONGS 2 CYCLE 8 INTEGRATED IMPLEMENTATION SCHEDULE UNIT 2 CYCLE 8 SCHEDULE A - NRC RULE OR ORDER MODIFICATION REFERENCE LETTER / COMMENTS THERE ARE N0 SCHEDULE A ITEMS IDENTIFIED AT THIS TIME.

UNIT 2 CYCLE 8 SCHEDULE B - REGULATORY C0f'HITMENT MODIFICATION REFERENCE LETTER / COMMENTS Provide Annunciator Alarms for Open LER 3-90-010 and SCE to NRC letter Containment Emergency Sump Isolation dated February 2, 1991 (DCP 6989)

Valves and Closed ECCS and CS Pump Mini Flow Valves Addition of Valves and Drains fcr IST Generic Letter 89-04 (DCP 6988)

Upgrade Target Rock Solenoid Valves Generic Letter 91-15 (DCP 6910.00)

Intake Structure Security Barriers SCE to NRC letters February 12, 1993 and July 15, 1993 (DCP 6999.00)

UNIT 2 CYCLE 8 SCHEDULE C - PLANT BETTERMENT l

MODIFICATION REFERENCE LETTER /COMMEN1S Install Removable Refueling Machine (DCP6864) j Controls Replace NMC Radiation Monitors (DCP6926)

Reorient / Replace CCW Containment (DCP6986.00)

Isolation Valves Containment Purge and Plant Vent Stack (DCP 6876)

Radiation Monitor 1

UNIT 2 CYCLE 8 SCHEDULE C - PLANT BETTERMENT (continued)

MODIFICATION REFERENCE LETTER / COMMENTS Replace Circ Water AT Data Logger (DCP6963)

Replace Loose Parts and Vibration (DCP 6851)

Monitoring System Turbine Governor Valve Modifications (DCP6914) 1 Snubber Reductions On-going program (DCP 6683.04)

Ladders and Platforms On-going program (DCP 6735.03)

RCS Vacuum Fill (DCP6941)

AVR Replacement (DCP6946) i Ex-core Neutron Detectors (DCP6984)

RCP Design Changes (DCP6990) i Replace TPSS Secondary Chemistry (DCP6885)

Instrumentation Replace HP1000 Computer and (DCP7032) l Meteorological Equipment Enclosure Replace HFMUD Chemistry Analyzers (DCP7034)

In-containment PAMI Improvements (DCP2005) l TGIS Instrument Replacement (DCP6933)

Degraded Grid Voltage (DCP2060)

Install Removable Digital Polar Crane (DCP6855)

Controls Talega #2 Transmission Line (DCP2062)

CRA 44 Card Replacement (DCP6908)

T-121 Nitrogen Blanket Sytem (DCP6877)

Load Center Transformer Replacement (DCP6974) 2

i ENCLOSURE 4 SONGS 3 CYCLE 8 SCHEDULES i

SONGS 3 CYCLE 8 INTEGRATED IMPLEMENTATION SCHEDULE UNIT 3 CYCLE 8 SCHEDULE A - NRC RULE OR ORDER MODIFICATION REFERENCE LETTER / COMMENTS

. i THERE ARE NO SCHEDULE A ITEMS IDENTIFIED AT THIS TIME.

UNIT 3 CYCLE 8 SCHEDULE B - REGULATORY COMMITMENT MODIFICATION REFERENCE LETTER / COMMENTS Provide Annunciator Alanns for Open LER 3-90-010 and SCE to NRC letter Containment Emergency Sump Isolation dated February 2, 1991 (DCP 6989)

Valves and Closed ECCS and CS Pump Mini Flow Valves l

Addition of Valves and Drains for IST.

Generic Letter 89-04 (DCP 6988)

Upgrade Target Rock Solenoid Valves Generic Letter 91-15 (DCP 6910.00)

Intake Structure Security Barriers SCE to NRC-letters February 12, 1993 and July 15, 1993 (DCP 6999.00) l UNIT 3 CYCLE 8 SCHEDULE C - PLANT BETTERMENT MODIFICATION REFERENCE LETTER / COMMENTS o

Install Removable Refueling Machine (DCP6864)

Controls l

Replace NMC Radiation Monitors (DCP6926)

Replace Circ Water AT Data logger (DCP6963) l Reorient / Replace CCW Containment (DCP6986.00)

Isolation Valves Containment Purge and Plant Vent Stack (DCP6876) 1 Radiation Monitor 4

1 w

r vtr v

w r-

-r-

.m r

.i,,

.#,m r

,,-,,..m

  1. ..-,., n

.,.e,,

UNIT 3 CYCLE 8 SCHEDULE C - PLANT BETTERMENT (continued)

MODIFICATION REFERENCE LETTER / COMMENTS Replace Loose Parts and Vibration (DCP6851)

Monitoring System Turbine Governor Valve Modifications (DCP6914)

Snubber Reductions On-going program (DCP 6683.04)

Ladders and Platforms On-going program (DCP 6735.03)

RCS Vacuum Fill (DCP6941)

AVR Replacement (DCP 6946)

Ex-core Neutron detectors (DCP6984)

RCP Design Changes (DCP6990) l Replace TPSS Secondary Chemistry (DCP6885)

Instrumentation Replace HP1000 Computer and (DCP7032)

Meteorological Equipment Enclosure Install Removable Digital Polar Crane (DCP 6855)

Controls CRA 44 Card Replacement (DCP6908)

Seismic Joint Repair (DCP6977)

In-Containment PAMI Improvements (DCP2005)

T-121 Nitrogen Blanket System (DCP6877)

Load Center Transformer Replacement (DCP6974) l 2

u_a h

ENCLOSURE 5 ONGOING EVALUATIONS OF MAJOR ISSUES (SONGS 2 AND 3)

ONG0ING EVALUATIONS OF MAJOR ISSUES (SONGS 2 and 3)

GL 88-20, SVP 4 Individual Plant Examination of External Events (IPEEE), to be completed by 6/01/95.

GL 89-10 The initial safety related Motor Operated Valve (MOV)

Testing and Surveillance will be completed for Units 2 and 3 by the end of their respective Cycle 8 refueling outages.

Periodic verifications of MOV operability will follow.