- 05000328/LER-1990-018-01, :on 901121,limiting Condition for Operation Entered RHR cross-tie Valve to Closed to Perform Maint to Correct Valve Torque Switch Setting.Caused by Inadequate Training of Personnel.W/Undated Ltr + (ML20065T604)
- PY-CEI-NRR-1272, Informs That Generic Ltr 89-10,Suppl 2 MOV Program Description & Schedule for Facility Complete & Available Onsite for Review + (ML20065T609)
- ML20065T611 + (ML20065T611)
- ML20065T612 + (ML20065T612)
- ML20065T615 + (ML20065T615)
- 05000328/LER-1990-017-02, :on 901123,reactor Trip Occurred as Result of low-pressurizer Pressure.Caused by Misunderstanding by Lead Reactor Operator & Failure to Maintain T Average & T Ref During Shutdown + (ML20065T620)
- W3P90-1919, Forwards Basis for 901224 Request for Temporary Waiver of Compliance from Tech Spec 3/4.3.4, Turbine Overspeed Protection, Surveillance Requirements 4.3.4.2a & B, Demonstrating Operability of Overspeed Protection Sys + (ML20065T628)
- ML20065T635 + (ML20065T635)
- ML20065T637 + (ML20065T637)
- ML20065T645 + (ML20065T645)
- ML20065T648 + (ML20065T648)
- ML20065T651 + (ML20065T651)
- ML20065T663 + (ML20065T663)
- ML20065T666 + (ML20065T666)
- ML20065T667 + (ML20065T667)
- 05000265/LER-1990-012-08, :on 901124,automatic Function of HPCI Pump Flow Indicating Controller (FIC) 2-2340-1 Failed Due to Unknown Causes.Hpci Declared Inoperable & Sys Outage Rept Initiated + (ML20065T669)
- ML20065T671 + (ML20065T671)
- 05000317/LER-1981-025, Forwards LER 81-025/03L-0 + (ML20065T672)
- ML20065T675 + (ML20065T675)
- ML20065T684 + (ML20065T684)
- JAFP-82-0020, Forwards Monthly Operating Rept for Dec 1981 + (ML20065T687)
- ML20065T689 + (ML20065T689)
- ML20065T692 + (ML20065T692)
- ML20065T695 + (ML20065T695)
- ML20065T698 + (ML20065T698)
- 05000317/LER-1981-025-03, /03L-0:on 810404,outer Personnel Air Lock Door Operating Mechanism Failed,Preventing Door from Closing. Caused by Broken Cam Follower in Door Operator Due to Clutch Malfunction.Insp & Maint of Clutches Added to Procedure + (ML20065T702)
- ML20065T704 + (ML20065T704)
- 05000373/LER-1982-025, Updated LER 82-025/03X-1:on 820516 & 17,during Leak Rate Testing,Drywell Equipment Sump Pump Started & Pumped Down Sump.Caused by Control Switches for Valves 1RE024 & 25 Left in Auto Position Instead of Closed Position + (ML20065T705)
- ML20065T709 + (ML20065T709)
- ML20065T711 + (ML20065T711)
- 05000301/LER-1982-007, Forwards LER 82-007/03L-0 + (ML20065T715)
- ML20065T721 + (ML20065T721)
- ML20065T726 + (ML20065T726)
- ML20065T730 + (ML20065T730)
- ML20065T732 + (ML20065T732)
- 05000301/LER-1982-007-03, /03L-0:on 820925,during Inservice Test of Pressurizer PORV & Block Valves,One of Two PORV Discovered Inoperable.Caused by Inadequate Work Procedure Performed Months Earlier Due to Closed Valve in Instrument Air Line + (ML20065T734)
- RBG-34193, Ro:On 901011,in-line Continuous Recording Conductivity Monitor for Reactor Coolant Sys Inoperable & on 901111, Continuous Recording Conductivity Monitor Inoperable for Total of 31 Days & Remained Until 901201,total of 51 Days + (ML20065T735)
- ML20065T737 + (ML20065T737)
- ML20065T739 + (ML20065T739)
- ML20065T742 + (ML20065T742)
- ML20065T743 + (ML20065T743)
- NRC-90-3557, Provides Summary of Westinghouse Actions Which Address Generic Implications of Tube Collapse Issue & Action Plan to Address Potential for Steam Generator Tube Distortion & Potential Collapse of Tubes,Per 901107 Request + (ML20065T746)
- ML20065T748 + (ML20065T748)
- ML20065T752 + (ML20065T752)