- 05000255/LER-1982-022-03, /03L-0:on 820730,during Insp of Ess sys,3/4-inch, 200 Psi,Threaded Bronze Valve Found Installed at MV-3420. Cause Undetermined.Bronze Valve Replaced.Current Documentation Methods Would Preclude Recurrence + (ML20064M831)
- ML20064M838 + (ML20064M838)
- 05000413/LER-1994-003-01, :on 940222,determined TS 3.3.1 Table 3.3-1 Action Statement Violations Occurred.Operations,Instrument & Electrical Procedures Revised + (ML20064M841)
- 05000277/LER-1982-021-03, /03L-0:on 820620,combined Leakage for Type B & C Tests Exceeded 0.6 La.Caused by Failure of MSIV Due to Improper Seat Contact Resulting from Damaged Seats,Plugs & Guides.Valves Repaired & Tested + (ML20064M845)
- ML20064M860 + (ML20064M860)
- ML20064M863 + (ML20064M863)
- 05000374/LER-1994-002-06, :on 940221,RCIC Turbine Exhaust Rupture Discs Ruptured During Sys Testing Due to Turbine Exhaust Line Pressure Spike.Rcic Sys Restored to Operability + (ML20064M872)
- 05000361/LER-1982-074-03, /03L-0:on 820729,condensate Storage Tank T-121 Water Level Fell Below Tech Spec.Caused by Inadequate Makeup Water Control to Tank & More Restrictive than Necessary Tech Spec + (ML20064M882)
- ML20064M888 + (ML20064M888)
- 05000361/LER-1982-159, Forwards Updated LER 82-159/03L-1.Detailed Event Analysis Submitted + (ML20064M889)
- ML20064M893 + (ML20064M893)
- ML20064M894 + (ML20064M894)
- ML20064M898 + (ML20064M898)
- 05000255/LER-1982-021, Forwards LER 82-021/03L-0 + (ML20064M909)
- ML20064M915 + (ML20064M915)
- 05000255/LER-1982-021-03, /03L-0:on 820729,during Surveillance of Hydraulic Snubbers,Snubber 31 Contained Insufficient Oil.Caused by Deteriorated O-rings.Failed Snubber Replaced + (ML20064M920)
- 05000361/LER-1982-077, Forwards LER 82-077/03L-0.Detailed Event Analysis Submitted + (ML20064M925)
- ML20064M929 + (ML20064M929)
- ML20064M930 + (ML20064M930)
- ML20064M931 + (ML20064M931)
- W3P83-0430, Notifies That Compliance w/NUREG-0737,Item II.E.4.2 Re Containment Pressure Setpoint (3.3 Psig),Has Been Calculated Using Explicit Setpoint Methodology Per SER Open Item. Info Will Be Included in FSAR Amend 31 + (ML20064M933)
- 05000361/LER-1982-159-03, Pressure Indicator 2PI-8300 for Steam Generator E-088 on Essential Plant Parameter Monitoring Sys Panel 21-411 Read Greater than Similar Indicator on Control Room Panel CR-52.Cause Unknown + (ML20064M935)
- ML20064M936 + (ML20064M936)
- 05000361/LER-1982-077-03, /03L-0:on 820725,containment Pressure Indicators 2P1-0351-2 & 2P1-0352-2 Failed Channel Check Test.Caused by Instrument Drift.Indicators Recalibr + (ML20064M940)
- ML20064M943 + (ML20064M943)
- ML20064M946 + (ML20064M946)
- ML20064M947 + (ML20064M947)
- ML20064M949 + (ML20064M949)
- ML20064M955 + (ML20064M955)
- ML20064M956 + (ML20064M956)
- ML20064M960 + (ML20064M960)
- ML20064M961 + (ML20064M961)
- 05000277/LER-1982-045-03, /03L-0:on 821230,while Performing Routine Decontamination of RHR Pump Room 2B,motor Found Wet to Extent Considered Inoperable.Caused by Personnel Error. Supervisor Reinstructed Vendor in Proper Method + (ML20064M966)
- ML20064M967 + (ML20064M967)
- ML20064M973 + (ML20064M973)
- ML20064M981 + (ML20064M981)
- ML20064M982 + (ML20064M982)
- ML20064M987 + (ML20064M987)
- 05000443/LER-1994-001-01, :on 940125,reactor Trip & Safety Injection Occurred Due to Inadvertent MSIV Closure.Caused by Hydraulic Fluid Contamination,Sticking Main Dump Valve & Related Hardware Issues.Msivs Disassembled & Inspected + (ML20064M988)
- 05000361/LER-1982-073, Forwards LER 82-073/01T-0.Detailed Event Analysis Submitted + (ML20064M990)
- ML20064M995 + (ML20064M995)
- ML20064M997 + (ML20064M997)
- 05000361/LER-1982-073-01, /01T-0:on 820826,min Level for Refueling Water Storage Tank Found to Be 87.5% Instead of 75% as Stated in Procedures S023-3-3.25 & S023-3-3.27.Caused by Misinterpretation of Words ECCS Suction Connection + (ML20064N001)
- ML20064N003 + (ML20064N003)
- ML20064N004 + (ML20064N004)
- ML20064N007 + (ML20064N007)
- 05000361/LER-1982-047, Forwards LER 82-047/01L-0.Detailed Event Analysis Submitted + (ML20064N022)
- 05000317/LER-1982-047, Forwards LER 82-047/03L-0 + (ML20064N026)
- 05000361/LER-1982-047-01, /01L-0:on 820714,auxiliary Feedwater Sys Valve 2HV4714 Was Slow in Stroking Open Rendering Motor Driven Pump 2P-504 Inoperable.Caused by Metal Shaving Found in Solenoid.Newly Calibr Solenoid Valve Installed + (ML20064N041)
- 05000317/LER-1982-047-03, /03L-0:on 820730,during Surveillance Testing, Channel C Reactor Protective Sys Low Flow Trip Setpoint Was Nonconservative.Caused by Improper Setting of Trip Units. Setpoint Corrected + (ML20064N052)
- ML20064N053 + (ML20064N053)